Home
User manual SLIM LINE
Contents
1. The water regulator can be adjusted up to 6 bar The minimum pressure is 2 2 bar Note When adjusting the pressure dispense product Venturi ejector The mixing ratio is adjusted on the ejectors When water flows through the ejector the concentrate mixes with the water The mixing ratio is regulated on the ejector There are two kinds one for products with cells and one for products without cells Turn the adjustment screws according to the label on the ejector in order to increase or decrease the amount of concentrate 4 Dispenser description of parts description Water valve The Water valve is connected to the ejector and opens the water flow Push button The push buttons on the front panel controls the water valves Use only one button at a time 5 Dispenser description of parts pe T Transformer The transformer is a 230 24 V 55VA The transformer supplies 24 V to the magnetic valves Thermostat The thermostat keeps the temperature within correct range Factory adjusted do not adjust this may cause damage and water leakage in the dispenser Illumination Behind the front panel there is a low energy fluorescent lamp with the effect off 24 W The fluorescent lamp is a PL lamp _ 6 Dispenser description of parts KLEE s Front panel The front panelis divided in three parts Two plastic sheets made off acrylic and opaque and in between thes
2. Cut the tube to correct length Clean pinch solenoid with hot water Untwist the tube Replace bag Check the valve on off sw inside the door Remove power to the dispenser and put it back on after 10 sec Change fuse Check water supply Check water regulator change needle valve in water regulator Shut off water supply and call service 14 Trouble shooting Probable cause Attend to The dispenser is not Clean ejector outlet pipes The taste is to strong cleaned properly and pinch solenoid weak The ejector is not adjusted Call service correctly It constantly drips Dirt in the water valve Call service fluid from the outlet pipes Troubles with cooling Call service system Failure in thermostat Call service The drinks are not cold Failure in cooling system Call service 15 Electrical connections Slimline with two products water and push buttons Stater Fluo tube Esz Reaktor Wietervalwes Yi Pinchalyves xo Pushbutton x3 ri Compressor 24 AC Tranetormer Thermostat SOV ohz 16 Technical data Electrical connection 230 V 50 Hz 2 5 A Water connection 3 0 m Tube with 3 8 internal thread minimum 2 5bar water pressure Compressor Elektrolux GL 80 Refrigerant HFC 134A Amount to fill 210 gram Cooling capacity 294 W Cooling system Dry block with stainless steel pipes inside Front light 24 W lamp Front sign size 265 x 481 mm 1
3. 6 mm must be transparent Applies on the bottom part of the sign Dispenser measurement Height 750mm With 250mm Depth 550mm Weight 34 Kg Note 1 The thermostat is factory adjusted and improper adjustment may cause the cooling system to freeze causing damage or water leakage in the dispenser Note 2 It is strongly recommended to use some sort of water isolator in the water line in case of an emergency leakage Note 3 Maximum ambient temperature in the room where the dispenser is located should not exceed more then 25 C Note 4 lf the dispenser has frozen check water tubs and connections inside the dispenser before running the dispenser again 17 COFFEE QUEEN SLIM LINE Juice machine FOR SERVICE Please contact your retail dealer Your retail dealer COFFEE QUEEN AB Box 960 671 29 ARVIKA bes ksadress Korpralsv 1B Tel vxl 46 0 570 47700 Fax 46 0 570 47719 E mail info coffeequeen se www coffeequeen se Art nr Art no 1704143
4. User manual SLIM LINE Juice machine Your retail dealer U EN Rev 090914 List of contents List of contents General description Dispenser description of parts Installation and users instruction Maintenance and cleaning Handling and cleaning instructions Maintenance and cleaning Trouble shooting Electrical connections Technical facts Notes page 2 page 3 page 4 7 page 8 10 page 11 page 12 page 13 page 14 15 page 16 page 17 page 17 Dispenser description for Slim line Slim Line is a dispenser for cooling water and mixing juiceconcentrate to a ready to drink product The dispenser is for two non carbonated drinks and chilled water The dispenser is connected to the water mains by a pressurised tube and to an electric wall socket by a power plug The water pressure is adjusted with the water regulator and the pressure is displayed on the manometer The water is chilled by the cooling block which in its turn is chilled by the air cooled compressor The water temperature is adjustable with a thermostat The mixing ratio product water is adjusted with the ejectors Pushing one of the four buttons on the front panel dispenses the mixed product or water General Read the instructions carefully before you start working with this equipment The equipment should be installed and serviced by trained staff 3 Dispenser description of parts Pe s Water regulator with manometer
5. cuuming the grid BR Te Fig 3 Fig 4 Fig 5 12 Maintenance and cleaning Periodic cleaning 1 Disconnect the bag in box tube from the venture 2 Fill the cleaning bottle with warm water and some washing up liquid and connect it to the venture 3 Shutthe dispenser door and put a cup under the outlet pipes rinse the venture and the outlet pipes by pressing the respective push buttons 4 Use the cleaning brush to clean the outlet pipes 5 Wet the brush in water and put it in the outlet pipe from the inside of the door Return the boxes and connect the tubes to the ventures 13 Trouble shooting Probable cause Attend to Concentrate is Dripping from outlet pipe Mostly water or only water coming from outlet pipe Nothing happens when I push the buttons and there is no clicking sound Nothing happens when you push the buttons and there is a clicking sound The tube is not properly fixed into the pinch solenoid valve The tube is kinked due to incorrect length The pinch solenoid needs cleaning The tube is twisted The bag is empty No power to the valves Thermo fuse in the transformer has cut On older models a fuse has blown Water supply turned off Water regulator turned off or failed Manometer 0 bar The cooling coil has frozen Manometer max pressure Fix the tube properly into the pinch solenoid valve
6. e a film All parts are removable Drip tray The drip tray is made of stainless steel with steel bars It is possible to connect drainage to the drip tray Large particle filter A large particle filter is fitted between the cooling block and the water valves It is possible to rinse the filter if needed T Installation and users instruction ran T Unpack dispenser from the packaging and ensure that nothing is damaged Place the dispenser to it s position Note The dispenser weights about 35 kg Don t lift by door Allow a space of min 40mm around the frame for air circulation Make sure that the dispenser level Adjustment can be made with the adjustable feet Adjustments 60mm From wall Min airflow If needed adjust foot up or down Use a water level tool for correct placement of machine ee SA a ng 8 Installation and users instruction ran Tee Connect the water hose from the dispenser to the cold water mains do not forget seals Turn on the water and check for leaks Note It is strongly recommended to use some sort of water isolator in the water line in case of an emergency leakage Connect the power plug to the wall socket Now the compressor starts and the front panel lights up The water pressure is factory adjusted to 2 2 bar which is the correct working pressure Check by pressing and holding one product button and reading the manomete
7. r If there is variations adjust by pulling black knob and turn it until you get a reading of 2 2 bar 9 Installation and users instruction crew m Place the bag in box in the dispenser and connect it to the pinch solenoid valve and ejector Pushing the centre of the pinch solenoid valve and sliding the tube in from the side fixes the tube Cut the tube to correct length and push it onto the elbow connector on the ejector Place a cup under the outlet pipe Dispense a glass of product by pressing the push button Check that the brix value mixing ratio is okay if not adjust To adjust the brix use the adjustment screw on the ejector The dispenser is now ready to use 10 Maintenance and cleaning Change of bag in box 1 Turnthe box so the perforated side is turned upwards 2 Brake the perforation on the box and place the main pipe in the punched hole 3 Place the box in the dispenser so that the tube points down to wards the pinch solenoid Press the end of the pinch solenoid and insert the tube from the side 4 Check the tube length so that it will reach 1cm into the venture nipple 5 Ifthe tube is to long cut it to the right length 6 Slip the tube to the venture nipple 7 Make sure that the tube is not twisted and shut the door to the dispenser 8 Place a cup under the outlet pipes and draw until the juice comes out Daily cleaning 1 Clean internal and external surface
8. with a damped rag 2 Use the cleaning brush to clean the outlet pipes 3 Wetthe brush in water and put it in the outlet pipe from the inside of the door 4 Clean the drip tray 5 The drip tray is made of stainless steel and can be washed in a dishwasher ae Pine ST 11 Handling and cleaning instructions 1 Open the Bag in Box at the perforation Pull out the silicon tube and the plastic connector so it is clear of the box 2 Place the box inside the dispenser Press in the pinch solenoid and slide the tube in to the opening Fig 2 3 Push the tube onto the ejector nozzle Fig3 4 The dispenser is now ready to use 1 When changing the Bag in Box the dispenser should be cleaned with hot water 2 Fill the rinsing bottle with a solution of hot water and a sanitising agent Add two drops of washing up liquid Connect the tube to the nozzle and wash it through Fig 4 3 Wet the brush in a hot water and sterilising solution Clean the outlet pipes by pushing the brush all the way through the pipe and back again Fig 5 4 Rinse the pipes with the water solution from the bottle 5 The pinch solenoid that the tube runs through should be cleaned on a regular basis by pouring a hot water and Sterilising solution over it This will dissolve any residual concentrate 6 The air inlet condenser at the back of the machine should be cleaned from dust on a regular basis by brushing or va
Download Pdf Manuals