Home

User Manual - Excalibur Engineering

image

Contents

1. 1 A Chinese English User s Guide 2 An AC power adaptor 3 A dual BNC coaxial cable 509 impedance RG58C UL 100cm length 4 High voltage dedicated dual banana plug silicon cable UL 20KV 18AWG 60cm length a red one and a black one 5 High voltage dedicated IC clip maximum 6500V DC AC p p a red one and a black one 6 Safety alligator clip UL 1000V CAT II 10A a red one and a black one 7 Safety contact probe prod UL 1000V CAT III a red one and a black one RP1000D User s Guide 11
2. L output Lahe BNC Interface Figure 1 RP1025D High Voltage Differential Probe RP1000D User s Guide 1 RIGOL Input Terminal Overload Indicator Power Indicator Attenuation Ratio and n Power Button Power Adaptor Interface Output Label BNC Interface Figure 2 RP1050D High Voltage Differential Probe 2 RP1000D User s Guide RIGOL Input Terminal Overload Indicator Power Indicator Attenuation Ratio and Power Button Power Adaptor IN Interface Output Label BNC Interface Figure 3 RP1100D High Voltage Differential Probe RP1000D User s Guide 3 RIGOL Basic Operations 1 Connect the red safety IC clip with one end of the red dual banana plug silicon cable and the black safety IC clip with one end of the black dual banana plug silicon cable provided in the accessories Then connect the red dual banana plug silicon cable with the red input terminal of the high voltage probe and the black dual banana plug silicon cable with the black input terminal of the high voltage probe Note a The safety IC clip can be replaced by safety alligator clip applicable to RP1025D and RP1050D b The high voltage dedicated IC clip can be replaced by safety alligator clip or safety contact probe prod applicable to RP1100D c The dual banana plug silicon cable can be replaced by high voltage dedicated dual banana plug silicon cable applicable to RP1100D 2 Connect on
3. RIGOL User s Guide RP1000D Series High Voltage Differential Probe Oct 2012 RIGOL Technologies Inc RIGOL Guaranty and Declaration Copyright 2012 RIGOL Technologies Inc All Rights Reserved Trademark I nformation RIGOL is a registered trademark of RIGOL Technologies Inc Publication Number UGE18100 1110 Notices RIGOL products are protected by patent law in and outside of P R C RIGOL reserves the right to modify or change parts of or all the specifications and pricing policies at company s sole decision Information in this publication replaces all previously corresponding material RIGOL shall not be liable for losses caused by either incidental or consequential in connection with the furnishing use or performance of this manual as well as any information contained Any part of this document is forbidden to be copied or photocopied or rearranged without prior written approval of RIGOL Product Certification RIGOL guarantees this product conforms to the national and industrial standards in China as well as the 1S09001 2008 standard and the 1S014001 2004 standard Other international standard conformance certification is in progress Contact Us If you have any problem or requirement when using our products please contact RIGOL Technologies Inc or your local distributors or visit www rigol com RP1000D User s Guide RIGOL General Safety Summary Please review the following safety pre
4. ak peak value or 450Vrms Voltage to ground at the input terminal 600Vrms Input mpedance Differential 4MQ 1 2pF Single ended and to ground 2MQ 2 3pF Output Voltage lt 7 0V Output 509 Impedance Rise Time X50 or X200 attenuation ratio 14ns X20 attenuation ratio 23 4ns Common mode 60Hz gt 80dB Rejection 100Hz gt 60dB 1MHz gt 50dB Power Supply Specified external 9V DC power supply must be specified products acknowledged by our company Power 0 4 watt Consumption RP1000D User s Guide RIGOL RP1050D Bandwidth X200 X500 or X1000 attenuation ratio DC 50MHz 3dB X100 attenuation ratio DC 25MHz Attenuation Ratio X100 X200 X500 X1000 Accuracy 2 Input Voltage Range DC AC peak peak value X100 attenuation ratio lt 700Vpp about 230Vrms or DC X200 attenuation ratio lt 1400Vpp about 460Vrms or DC X500 attenuation ratio lt 3500Vpp about 1140Vrms or DC X1000 attenuation ratio lt 7000Vpp 2300Vrms or DC Maximum I nput Voltage Maximum differential voltage 7000V DC AC peak peak vale or 450Vrms Voltage to ground at the input terminal 6500Vrms Input I mpedance Differential 100MQ 1 2pF Single ended and to ground 50MQ 2 3pF Output Voltage lt 7 0V Output 509 I mpedance Rise Time X200 X500 or X1000 attenuation ratio 7ns X100 attenuation ratio 14ns Common mo
5. cautions carefully before putting the instrument into operation so as to avoid any personal injuries or damages to the instrument and any product connected to it To prevent potential hazards please use the instrument only specified by this manual Ground The I nstrument The instrument is grounded through the Protective Earth lead of the power cord To avoid electric shock it is essential to connect the earth terminal of power cord to the Protective Earth terminal before any inputs or outputs Observe All Terminal Ratings To avoid fire or shock hazard observe all ratings and markers on the instrument and check your manual for more information about ratings before connecting Do Not Operate Without Covers Do not operate the instrument with covers or panels removed Avoid Circuit or Wire Exposure Do not touch exposed junctions and components when the unit is powered Do Not Operate With Suspected Failures If you suspect damage occurs to the instrument have it inspected by qualified service personnel before further operations Any maintenance adjustment or replacement especially to circuits or accessories must be performed by RIGOL authorized personnel I RP1000D User s Guide RIGOL Keep Well Ventilation Inadequate ventilation may cause increasing of temperature or damages to the device So please keep well ventilated and inspect the intake and fan regularly Do Not Operate in Wet Conditions In order to avoid s
6. de 60Hz 5 80dB Rejection 100Hz 5 60dB 1MHz gt 50dB Power Supply Specified external 9V DC power supply must be specified products acknowledged by our company Power 0 4 watt Consumption RP1000D User s Guide RIGOL RP1100D Bandwidth X200 X500 or X1000 attenuation ratio DC 100MHz 3dB X100 attenuation ratio DC 25MHz Attenuation Ratio X100 X200 X500 X1000 Accuracy 2 Input Voltage Range DC AC peak peak value X100 attenuation ratio lt 700Vpp about 230Vrms or DC X200 attenuation ratio lt 1400Vpp about 460Vrms or DC X500 attenuation ratio lt 3500Vpp about 1140Vrms or DC X1000 attenuation ratio lt 7000Vpp about 2300Vrms or DC Maximum I nput Voltage Maximum differential voltage 7000V DC AC peak peak value or 450Vrms Voltage to ground at the input terminal 6500Vrms Input mpedance Differential 100M92 1 2pF Single ended and to ground 50M92 2 3pF Output Voltage lt 7 0V Output 509 Impedance Rise Time X200 X500 or X1000 attenuation ratio 3 5ns X100 attenuation ratio 7ns Common mode 60Hz gt 80dB Rejection 100Hz gt 60dB 1MHz gt 50dB Power Supply Specified external 9V DC power supply must be specified products acknowledged by our company Power 0 4 watt Consumption RP1000D User s Guide RIGOL Operation Environment Operation Environment Gen
7. e end of the dual BNC coaxial cable to the BNC output terminal of the high voltage differential probe and the other end to input terminal of the oscilloscope 3 Turn on the channel switch on the oscilloscope and adjust the high voltage probe and oscilloscope to make the attenuation ratios of the two match If the attenuation ratio of the oscilloscope does not match that of the high voltage probe for example the attenuation ratio of the oscilloscope is set to 1X the actual vertical scale equals the attenuation ratio of the high voltage probe times the vertical scale of the oscilloscope 4 RP1000D User s Guide RIGOL For example when the attenuation ratio of the high voltage probe is set to X200 and the vertical scale of the oscilloscope is 0 5V div the actual vertical scale is 200X0 5V div 100V div Note When the attenuation ratio of the oscilloscope matches the attenuation ratio of the high voltage probe the vertical scale displayed on the oscilloscope is the actual scale When the input impedance of the oscilloscope is 509 the actual vertical scale is 2X200X0 5V div 200V div RP1000D User s Guide 5 RIGOL Maintenance Please use the specified tools to maintain this product For any maintenance done by unprofessional personnel RIGOL will not take any responsibility Please store this product in anti humidity case if the product will not be used for more than 60 days Cleaning This product has no particular req
8. eral Operation Storage Temperature 20 C to 30 C 0 C to 50 C 30 C to 70 C Humidity lt 70 RH 10 to 85 RH 10 to 90 RH General Specifications Probe Dimensions RP1025D about 214mm x 60mm x 35mm RP1050D about 240mm x 85mm x 36mm RP1100D about 240mm x 85mm x 36mm Weight RP1025D 280g RP1050D 280g RP1100D 280g Safety EC 1010 1 CAT III pollution degree 2 Electromagnetic Conform to EN50081 1 and 50082 1 Compatibility standards Maximum Voltage to RP1025D 600Vrms Ground RP1050D 6500Vrms RP1100D 6500Vrms Using Environment Indoor environment Insulation Category Double insulation 10 RP1000D User s Guide RIGOL Accessories RP1025D 1 A Chinese English User s Guide 2 An AC power adaptor 3 A dual BNC coaxial cable 509 impedance RG58C UL 100cm length 4 Dual banana plug silicon cable UL 6KV 18AWG 60cm length a red one and a black one 5 Safety IC clip UL 1000V CAT III a red one and a black one 6 Safety alligator clip UL 1000V CAT II 10A a red one and a black one RP1050D 1 A Chinese English User s Guide 2 An AC power adaptor 3 A dual BNC coaxial cable 509 impedance RG58C UL 100cm length 4 Dual banana plug silicon cable UL 6KV 18AWG 60cm length a red one and a black one 5 Safety IC clip UL 1000V CAT III a red one and a black one 6 Safety alligator clip UL 1000V CAT II 10A a red one and a black one RP1100D
9. g Earth Ground Ground Terminal IV RP1000D User s Guide RIGOL Contents Guaranty and Declaration a l General Safety Summary lI Safety Terms and Symbols sssssssssssnnnunnnnnnunnnnnnnnnnnnnnnnnnnnnnnnnnnn n IV RP1000D Overview 2222 AA 1 Basic Operations iha an kaan muida inanan dana 4 Maintenance 4 22 AA 6 Cleaning AA 6 WarraNty AA 6 Specifications aaa 7 Technical Specifications ie asana nana 7 Operation Environment aaaa nsaan 10 General Specifications eee 10 ACCESSOTiES 22m naaa na Kan KA A KA anadai NAAN NAAN N NAAN KANA KANA KANA KANA KK NANANA NAAN AAN 11 RP1000D User s Guide V RIGOL RP1000D Overview RP1000D series high voltage differential probe can convert high differential input voltage to low voltage and display the waveform on oscilloscope Its working frequency is up to 25MHz RP1025D 50MHz RP1050D and 100MHz RP1100D and it is rather suitable for large electricity test and R amp D RP1000D series high voltage differential probe is applicable to general purpose oscilloscope and its output label is the relative attenuation when the input impedance of the oscilloscope is 1MQ The relative attenuation will double when the input impedance of the oscilloscope is 50Q Input Terminal Overload Indicator Attenuation Ratio and Power Button Power Indicator Power Adaptor Interface tout
10. hort circuiting to the interior of the device or electric shock please do not operate in a humid environment Do Not Operate in an Explosive Atmosphere In order to avoid damages to the device or personal injuries it is important to operate the device away from an explosive atmosphere Keep Product Surfaces Clean and Dry To avoid the influence of dust and or moisture in air please keep the surface of device clean and dry Electrostatic Prevention Operate in an electrostatic discharge protective area environment to avoid damages induced by static discharges Always ground both the internal and external conductors of the cable to release static before connecting RP1000D User s Guide III RIGOL Safety Terms and Symbols Terms in this Manual These terms may appear in this manual i WARNING Warning statements indicate the conditions or practices that could result in injury or loss of life N CAUTION Caution statements indicate the conditions or practices that could result in damage to this product or other property Terms on the Product These terms may appear on the Product DANGER indicates an injury or hazard may immediately happen WARNING indicates an injury or hazard may be accessible potentially CAUTION _ indicates a potential damage to the instrument or other property might occur Symbols on the Product These symbols may appear on the product Double Safety Protective Chassis Test Insulation Warnin
11. uirement for cleaning To clean the probe please wipe the probe surface using soft and clean cloth dampened with detergent Warranty RIGOL warrants that its products mainframe and accessories will be free from defects in materials and workmanship within the warranty period If a product is proven to be defective within the respective period RIGOL guarantees the free replacement or repair of products which are approved defective To get repair service please contact with your nearest RIGOL sales and service office RIGOL does not provide any other warranty items except the one being provided by this summary and the warranty statement The warranty items include but not being subjected to the hint guarantee items related to tradable characteristic and any particular purpose RIGOL will not take any responsibility in cases regarding to indirect particular and ensuing damage 6 RP1000D User s Guide Specifications RIGOL Technical Specifications RP1025D Bandwidth X50 or X200 attenuation ratio DC 25MHz 3dB X20 attenuation ratio DC 15MHz Attenuation Ratio X20 X50 X200 Accuracy 2 Input Voltage Range DC AC peak peak value X20 attenuation ratio lt 45Vrms or DC X50 attenuation ratio lt 350Vpp about 110Vrms or DC X200 attenuation ratio lt 1400Vpp about 450Vrms or DC 140Vpp about Maximum I nput Voltage Maximum differential voltage 1400V DC AC pe