MSP RAPID ADMS Suite USER GUIDE - MSP
Contents
1. View Help RAPID 14 Feb 11 Ai cycled Tos File Running Doc Ref No MSP RAPID ADMS Suite User Guide v1 0 Page 30 4 2 RAPID SiteComs Workflow Initialize RAPID SiteComs 4 Scan for Raw data on DataOut Folder Send Data via GSM GPRS UHF Sucessfully Transmit data Doc Ref No MSP RAPID ADMS Suite User Guide v1 0 Page 31 5 0 MSP RAPID OffComs 5 1 Setting up MSP RAPID OffComs 5 1 1 Configure RAPID OffComs for receiving remote data 1 Launch the RAPID OffComs Program 2 Click File Menu gt Edit Settings General Settings Ouput File Path GSM Port Call Handling SMS Port SMS Password CO 12 g RAFIO SMS Alert Recipients separate by camma Cancel 3 Setup the Out File Path Output file Path Set where to save the data received from the RAPID SiteComs By default it is set to C Program Files RAPID ADMS OffComs Data GSM Port Choose the Comport which the receiving modem is connected Call Handling Set how the connected modem will responses to the incoming data call Default setting is Answer Click OK button to save the configuration 5 2 Add new Project 1 Click on Project Menu gt Add Project Project Settings Project Phone No RAPID 6591 088404 Doc Ref No MSP RAPID ADMS Suite User Guide v1 0 Page 32 Project Name Project name should match the project name configured on RAPID PC and RAP
2. 1 Project may consist of multiple Stations to do this User may create new project and set different station name Doc Ref No MSP RAPID ADMS Suite User Guide v1 0 Page 23 3 3 RAPIC PC Command Menus 1 File Menu Fie Controls Training Grientati ce Settings Cut AIL F4 Under the File Menu Users can Open the Project settings for any parameters needed to be changed 2 Controls Menu Contras Training Orientation d Jk F3 Power OFF F4 Guide Light On CIE Guide Light OFF trl F4 Check Level Ctrl L Check Face Ctrl F Change Face Ctrl H Take Reading Fid Initialize Instrument Fil Controls Menu contains the basic commands to control the Total Station Under Controls Menu users can have full control to the Total Station this Menus are essential when troubleshooting connection between PC and Total Station 3 Training Menu Orientation Monitoring d k dd Point Load Coordinate Ctrl D Import Training Ctrl I Doc Ref No MSP RAPID ADMS Suite User Guide v1 0 Page 24 When adding points prisms to be monitored Users may Train the points or Import Training data from existing file When doing a Training of prisms RAPID PC will register the coordinates of the prism and save all the training data into a file called Training File Training File is Located under C Program Files RAPID ADMS RAPID Training Training Files is in ini format It is required for the users
3. 5 ca Je SETTINGS Settings mode dei SETTINGS Mode E 1 2 Setting On the Instrument NET1 m NET1m Il and NET1AX m have factory default setting for monitoring In the event that other types of instrument are being used the instrument parameters have to set manually as below User is advised to read through the Instrument s User Manual prior to these settings Press Esc key until the Main menu is displayed as follows Doc Ref No MSP RAPID ADMS Suite User Guide v1 0 Page 5 SOKKIA NET 1AX m S N 100546 ee E MEAS Select Config from Menu EF 2 Inst MER SEN Customize C 3 Inst cons 3 Inst cons 9 8 Password 8 Password b Ap B 9 Motor Sa B e scomms assez ze 1 j 1 2 1 Obs Condition Setting Please check or change the following setting as listed below Factory Default setting of NET1AX m Dist mode S Dist Tilt crn Yes H V Tilt error No Action Doc Ref No MSP RAPID ADMS Suite User Guide v1 0 Page 6 Coll crn Yes Cand R crn No V manual No Obs condition Dist mode bie sl Tilt ern eH vy sl Tilt error No action sl Col em rs E C andr ern No vraoa FR E V obs Zenith Coordinates N E Z Ang reso 0 0002gon Dist reso 0 1mm ppm settings Press Temp Obs condition Zenith Coordinates INEZ Sea level cmn No Ang reso o 00002gon Dist reso CO imm Press OK t
4. 6 View Menu ove fons Degrees On the View Menu Users can see the Project Layout and can switch to Degrees view See below the example of Project Layout View O PS05 O PS06 Orso O G tt 10 O PS PS012 P6D P5014 O PS016 S017 p Ps018 MREF4 OPS019 Doc Ref No MSP RAPID ADMS Suite User Guide v1 0 Page 26 3 4 RAPID PC Monitoring Procedures Here are the Standard Procedures to be done when doing monitoring using RAPID PC Je 3 4 1 3 4 2 Setup Project Parameters Train Prism Points Done only on Initial setup Start Monitoring Optional Re Orientation Re Section How to Train Points To do Training of Points First Users have to manually point the Total Station to a specific Prism Users may not actually point to the center of the prism because RAPID PC has the auto center feature This enables the Total station to auto center to the prism whenever it reads a prism After pointing to the prism Users need to Click on Training Menu then click on Add point or simply click F6 By default Prism name is XYZ001 XYZ002 consecutively For the Reference Points It should be named with REF By doing this RAPID PC can easily verify which are the reference points Users may still rename the point after training by Going to Training Menu then Rename Point How to Start Monitoring When all the Points have been Trained Users may Enable Cycle Timer or Start Monitoring
5. No MSP RAPID ADMS Suite User Guide v1 0 Page 1 6 1 1 Configuring MSP RAPID DataChecker File Paths eesteg ggebres deeg deeg een kreere renerne nerne 35 612 Adding e eer ee een niae n EEEE ene ee ee eee 35 6 2 Starting the MSP RAPID DataChecker ac castasiccs ac teexcnietx aa saedn tate unaegbensoctuiosageanaadeunannees ocatudasaoatbadeionastentectaueeseiacnenss 37 6 3 MSP RAPID DataChecker eg TEE 38 E M FRAP a os 0 ea ee ne Orne ren een ne ae ee ee 39 Tsk Setting up MSP RAPID St r PHO poserer atequiteeneteatateocaceaupecttecauasebacteorcucasacattdsauhess se theaesetuneetcaawantenensayssowidatteaansteas 39 7 1 1 Configuring MSP RAPID St rPro Settings 25 serne sete eee eee hende EE R NE 39 Thad Re ELS PI ee 40 MiMi Editing the TE 41 TEL Daar POCOS 10 ere E e re eee eer eee ee ee ee ee ee ee 42 Ti na CN 44 v rk Generating Reports tee 44 Jas MSF IR ID SPO Aerer 48 kee 49 8 1 ee EEN 49 Doc Ref No MSP RAPID ADMS Suite User Guide v1 0 Page 2 1 0 Configuring Instrument 1 1 To Power Instrument To configure the Instrument power must be supplied to the Instrument for configuration The user is able to power the Instrument internally using the Internal Battery BDC58 or external battery using the Y cable Eater EC SAAC 110i 240 WAC Ee 1138 190 bo 125 VAC Extemal battery BS 2 VOR Take out the Power Converter EC117 Power unit AC to DC output together with the cables and connect t
6. immediately By enabling Cycle timer RAPID PC will be on standby and wait to finish the counter at the bottom left By Starting the monitoring immediately RAPID PC will automatically commence the monitoring cycle Doc Ref No MSP RAPID ADMS Suite User Guide v1 0 Page 27 3 5 RAPID PC Shortcut keys RAPID PC Shortcut key list Edit Settings Ctrl F2 Exit Ctrl F4 Power On F3 Power Off F4 Guide Light On Ctrl F3 Guide Light Off Ctrl F4 Check Level Ctrl L Check Face Ctrl F Change Face Ctrl H Take Reading F10 Initialize Instrument F11 Add Point F6 Insert Point F7 Retrain Point F8 Rename Point F2 Verify Point F9 Delete Point Del Load Coordinate Ctrl D Import Training Ctrl Doc Ref No MSP RAPID ADMS Suite User Guide v1 0 Re Orientate Ctrl O Resection Ctrl R Reset Count Ctrl X Enable Cycle Timer Ctrl S Start Monitoring Ctrl M Open Data File F12 Delete Cycle Shift Del Show Layout Ctrl V Page 28 4 0 MSP RAPID SiteComs 4 1 Setting up MSP RAPID SiteComs 1 Launch the RAPID SiteComs Application RAPID SiteComs File Edit View Help AAPIO 14 Feb 11 cycle Tb3 File Running 2 Go to Edit gt Settings 3 In the Settings windows configure the necessary required settings Settings Auto Launch Enabled vw Ww Input File Path CA D ataout Connection GPRS GSM Server P Address 116 12 193 5 Connection ID
7. requires StarNet Installed on the Processing PC StarNet Dongle license is required for processing multiple data 7 1 1 Configuring MSP RAPID StarPro Settings Open the MSP RAPID StarPro application Click File gt Edit Settings RAPID StarPro s ge EE mere Project Report View Help LES Edit Settings H EI bel Start Processing F3 08 Aug 11 9 23 Aug 11 Import Files Ctrl I Open File Ctrl 0 Select All Ctrl A Delete File Del Exit File Paths Input File Path Directory where RAPID STARPRO scan for data to be processed The default path is C Program Files RAPID ADMS StarPro Dataln This should match the output file path of the RAPID DataChecker OutputPath Sets the directory where the processed data will be saved Default path is C Program Files RAPID ADMS StarPro DataOut Alarm Notification Admin Email One email address is required for sending out Email notifications Modem Port PC ComPort where the modem is connected Modem will be required for SMS Alarm notifications Click OK to save settings Doc Ref No MSP RAPID ADMS Suite User Guide v1 0 Page 39 RAPID StarPro ECK A subdirectory will be created inside the output path for each SW project Make sure that both paths have write acess Input Path Output Path Admin Email Modem Port 7 1 2 Creating Adding new Project 1 On the Project Menu click on Add Project The Project Settings will be displayed Fi
8. the site condition by default value temperature is 30 C and Pressure 1013hPA Prism constants Refers to the offset of the centre of the prism by default 30 00mm for Reference and Monitoring Prism Output File Path Set where the data readings will be saved By default it is set to C Dataout Backup File Path Sets where the data will be back up Default path is C Program Files RAPID ADMS Rapid Backup Sequence Set how the Total Station will sequentially reads the prism e Reads all points in F1 then back again in F2 Total Station will read all prisms on Face 1 first and then will read again on Face 2 mode e Reads each point in F1 and F2 Total station will take reading on a prism in Face 1 and Face 2 then move to another point e Read all points in F1 only Total station will take readings only in Face 1 mode Repeats Set the number on repeats for the Total station to do the sequence Retries Sets the number of attempts of Total Station to read a prism In case the Total station reached the number of retries the Total Station will then move to the next point Cycle Mode Sets whether the Total Station will monitor by time triggered or by non stop monitoring For Interval Monitoring Interval Sets the number of hours between each monitoring This will affects the number of monitoring cycles per day Start time Sets the time for the Total Station to start monitoring Click OK button when all the settings are done Note
9. 7 21 MB of space available on the C drive InstallShield Doc Ref No MSP RAPID ADMS Suite User Guide v1 0 Page 20 5 Click on Install Button to begin installation Back button to change installation settings or Cancel button to abort installation Le RAPID ADMS Suite InstallShield Wizard a Click Install to begin the installation If you want to review or change any of your installation settings click Back Click Cancel to exit the wizard InstallShield Once the Installation is done click the Finish button Shortcuts for the RAPID ADMS Modules are automatically displayed on the Windows desktop RAPID ADMS Suite InstallShield Wizard InstallShield Wizard Complete Setup has finished installing RAPID ADMS Suite on your computer Back Cancel Doc Ref No MSP RAPID ADMS Suite User Guide v1 0 Page 21 Duce Setting Up RAPID PC 1 In the initial launching of the RAPID PC the Project option windows will be displayed Select Station RAPID STN COMTE rame Open From here Users have the option to Open existing project Add new project or Delete new Project For adding new Project It is required for the Users to set up Project Setting Parameters Setting up Project parameters is done only once Station Settings Project Name RAPID Station Name STN1 sequence Read all points in F1 then back againinF2 w Serial Port COM16 v S ISS 9600 v Repeats Retries I
10. ADMS Suite User Guide v1 0 Page 10 ppm Menu Temperature 15 OC Pressure 1013 hPa Humidity 50 ppm 0 Press OK to return to the sub menu of Config 1 2 4 Communication Setting EDM configurations Temperature Pressure Checksum Controller 2Way Remote D OPO Vac Doc Ref No MSP RAPID ADMS Suite User Guide v1 0 Page 11 Communication Setup Menu Checksum Controller Xon Xoff Baudrate Data bits Parity Stop bit RS232C Menu Baudrate Data bits Parity Stop bit Bluetooth Menu if any Mode Link Authentication Passkey Press OK to return to the Config menu No 2WAY REMOTE Yes E bits Not set H bit Yes 9600bps 8 bits Not set 1 bit Slave Option set 1234 Doc Ref No MSP RAPID ADMS Suite User Guide v1 0 Page 12 1 2 5 Units Setting Configuration Temperature Pressure Angle Distance Meter Unit Menu Temp rature Celcius Pressure hPa Angle Gon Distance Meter Press OK to return to the Config menu Doc Ref No MSP RAPID ADMS Suite User Guide v1 0 Page 13 1 2 6 Motor Setting Configuration Accu search Centering mode A Setting Configuration Menu Accu search Rapid Centering mode Standard A T Setting None Accu Rotate 10 Doc Ref No MSP RAPID ADMS Suite User Guide v1 0 Page 14 Motor confiquration Configur
11. ID SiteComs Phone Number For GSM connection Phone number of the remote modem is required Click OK button to save the configuration Note Added Projects are listed on the left panel of the window Received data for a project will be shown on the right panel of the window Project statuses are indicated under Project names Once RAPID Offcoms detected a incoming data project status will then be changed to connected F RAPID OffComs File Project View Help ep BARID Not Connected D b lt 15 Feb 11 10 00 Running Doc Ref No MSP RAPID ADMS Suite User Guide v1 0 Page 33 5 3 MSP RAPID OffComs Workflow Initialize RAPID OffComs at T Scan for Incoming data transmission via GSM GRPS UHF Incoming Data Detected Authentication Handshaking established Store Data in the Output File Path Doc Ref No MSP RAPID ADMS Suite User Guide v1 0 Page 34 6 0 MSP RAPID DataChecker 6 1 Setting up MSP RAPID DataChecker 6 1 1 Configuring MSP RAPID DataChecker File Paths Open the RAPID DataChecker Application Click File gt Edit Settings Checker 2 SETTINGS Input File Path Ie Program Files RAPID AM Vi ataCheckerD ata zE Backup File Fath C Program Files AAPID ADS YO ataChecker Backup Cancel Input File Path Sets where the RAPID DataChecker will scan for rpd files This sh
12. Local 4rea Metwork Ke Gemer Phone Ho 160625005069 Modem Fort COM 12 k SMS Password Dei Cancel Auto Launch Enables the RAPID SiteComs to automatically run whenever the PC have rebooted Doc Ref No MSP RAPID ADMS Suite User Guide v1 0 Page 29 Input File Path A path to which the SiteComs will search for data Detected data will be transferred to the processing server via GPRS or GSM connection Input File path should match the output file path of the RAPID PC Connection Choose which connection to be used for data transmission GPRS GSM GPRS priority and GSM as a secondary connection GSM GPRS GSM priority GPRS as a secondary connection GSM use on GSM connection GPRS use only GPRS connection GPRS Settings Server IP Address input the IP address on the processing server As default MSP Server s IP 116 12 193 5 is configured Connection ID Choose which connection to be used from the available network connection from the PC adapters GSM Settings Note GSM sends data SMS to the processing server A GSM modem is required when using GSM transmission Server Phone Number Input the phone number of the modem connected to the processing server Modem Port Comport to which the GSM modem is connected SMS Password Input the SIM card password if required Click OK when settings are done Successfully transferred data will be shown on the right panel on the application RAPID SiteComs File Edit
13. art 18 Feb 11 End Doc Ref No MSP RAPID ADMS Suite User Guide v1 0 Page 47 7 3 MSP RAPID StarPro Workflow Setup Input File Path Output File Path e Add and configure Project Settings v Import Reference File Input SMS and email notification e Start RAPID StarPro Scan for input file in the Data In Folder Data in detected in the StarPro Data in folder Call StarNet for Processing y Is StarNet Installed or Dongle detected Generate output data into Dataout folder User Manually generate Tabulated report from choosen date and cycle Doc Ref No MSP RAPID ADMS Suite User Guide v1 0 Page 48 8 0 Licensing 8 1 Licensing Key MSP RAPID ADMS Suite is protected by a USB dongle key MSP RAPID ADMS License package is included at the MSP RAPID USB Dongle the license package will determine which application in the MSP RAPID ADMS Suite is activated Without RAPID License dongle RAPID PC can only operate on demo mode On Demo mode users can only train up to 5 prisms and 1 round of cycle Please contact your nearest distributor to request for a hardware key Two type of RAPIDUSB Dongle key MSP RAPID USB Dongle key for Site This contains License for MSP RAPID PC and MSP RAPID SiteComs MSP RAPID USB Dongle key for Office This contains License for MSP RAPID OffComs MSP RAPID DataChec
14. ation i Vertical Horizontal Search Area Menu Vertical 1 5 Horizontal 1 5 JOG Setting Menu L L3 H H4 Shift 2 Press OK to return to the sub menu of Config Date amp Time optional Doc Ref No MSP RAPID ADMS Suite User Guide v1 0 Page 15 Please note that setting the Date and Time to the current does not affect the monitoring output This setting is within the instrument only This setting is optional Configuration Press Back to return to the main menu NET 1AX m S N 100546 JOE JOB1 Person The configuration of the instrument is now complete Select Measure menu to go into the measuring screen Doc Ref No MSP RAPID ADMS Suite User Guide v1 0 Page 16 Basic measurement L H o 314 94682 53 47930 1 A MOTOR oT DIST Pi Switch off the instrument manuallyby pressing both of these buttons on the front panel together 2 Doc Ref No MSP RAPID ADMS Suite User Guide v1 0 Page 17 1 0 2 0 MSP RAPID ADMS Suite Overview MSP RAPID ADMS Suite is a combination of application to carry out automatic deformation monitoring for tunnels viaduct High Low rise building mining sites DAMs roads and bridges RAPID ADMS Stands for RAPID Remote Automatic Precise Intelligent Detector for ADMS Automatic Deformation Monitoring System MSP RAPID PC is the core monitoring Software it takes control of the Instr
15. cessing A Status label is located on the lower left corner of the application RAPID DataChecker is advised to be running 24 7 for continuous processing of data Station gt Edit Edit the highlighted Project Configuration and training file can be changed on this option Station gt Delete Removes the highlighted Project from the list View gt Refresh Refresh the project s view and clear the list of the processed data Doc Ref No MSP RAPID ADMS Suite User Guide v1 0 Page 36 6 2 Starting the MSP RAPID DataChecker To start scanning of data Go to File Menu and then click on Start Once the RAPID DataChecker is running it will keep on scanning for any incoming files to be checked Station View BH Cu Alt F4 Doc Ref No MSP RAPID ADMS Suite User Guide v1 0 Page 37 6 3 MSP RAPID DataChecker WorkFlow Setup Folder Input and Backup File Path e Setup Project and Station I Import Training File A Start RAPID DataChecker l Scan for data in the Input Folder v Data detected on Input Folder Backup data Backup Folder Determine if the Data is good or bad data Bad data Good Data Save the data into the Output File Path directory Doc Ref No MSP RAPID ADMS Suite User Guide v1 0 Page 38 7 0 MSP RAPID StarPro 7 1 Setting up MSP RAPID StarPro Note RAPID StarPro
16. d reference file on the right panel of the application Right click on the point or Select All to edit multiple points Check the check box of the settings to be changed Rotation Angle Alarm Triggers Easting northing and reduced level can be adjusted RAPID StarPro La R i n R 8 Tick checkbox of point settings to update Parameter values will bbe applied to all selected paints W Aotation Angle W Alarm Triggers Easting E Northing E Reduced Level Click OK to save the changes Doc Ref No MSP RAPID ADMS Suite User Guide v1 0 Page 41 7 1 4 Data Processing 1 Make sure StarPro is running to start data processing Start or Stop data processing by clicking File Menu gt Start Stop Processing 2 MSP RAPID StarpPro automatically detects the input files on the directory of Input File Path C Program Files RAPID ADMS StarPro Dataln 3 Input files are shown on the middle panel of the application Zee een Hal ee ae se p W FAF a S STNI D 1 34 KB E 4 Processed data will be listed on the Data Panel of the application 03 Feb 11 wv AE 18 Feb 11 v CN Refresh A Fay d Cycle 4 Alarm Level 3 Doc Ref No MSP RAPID ADMS Suite User Guide v1 0 Page 42 Data that reached a trigger level will be highlighted Green color for level 1 Orange for Level 2 Red for level 3 Tabulated readings can be viewed by double clicking the data and will be opened on Microsof
17. downloading or otherwise using the Software including use by an employee agent independent contractor or any other party under control of the Customer you are confirming that you have read and understood this Agreement and agree to be bound by the terms of this Agreement If you do not agree to these terms s G accept the terms of the license agreement I do not accept the terms of the license agreement istallShield Doc Ref No MSP RAPID ADMS Suite User Guide v1 0 Page 19 S Choose the Installation Destination Folder for the RAPID ADMS It is recommended to use the default settings Installation folder to C Program Files RAPID ADMS Le RAPID ADMS Suite InstallShield Wizard ae Setup will install RAPID ADMS Suite in the following folder To install to this folder click Next To install to a different folder click Browse and select another folder Destination Folder C Program Files RAPID ADMS Check the RAPID Modules that are to be installed RAPID ADMS Suite is composed of 5 Modules MSP RAPID PC MSP RAPID SiteCOMS MSP RAPID OffCOMS MSP RAPID DataChecker MSP RAPID StarPro r RAPID ADMS Suite InstallShield Wizard a Select the features you want to install and deselect the features you do not want to install Description RAPID PC RAPID ADMS Suite RAPID SiteComs RAPID OffComs RAPID DataChecker RAPID StarPro 32 90 MB of space required on the C drive 4019
18. he singular cable to the NET MS Instrument Connect the power side of the EDC121 Y cable to the power source GAC adapter Power cable AC adapter Y cable EDcC139 EDC 121 100 to 240 WAC Doc Ref No MSP RAPID ADMS Suite User Guide v1 0 Page 3 Basic Key Operation Display BACKSPACE ap SHIFT ESC GE KI EI vi ch 0 to 97 SETTINGS Dt ge e TARGET _ Light sensor Softkey selection SPACE FUNC CTRL Switch the Instrument ON manually by pressing the button O on the front panel of the instrument The Instrument should be switch on at this moment with a beep audio If not please check the connection diagram supplied with the instrument or checks the power source Slide the pointer pen out from behind the right bottom of the display panel of the Instrument A 0 00258 0 00060 TOFS BACK It is always a good practice to level the instrument via bubble before switch on and then level it through the electronic bubble Doc Ref No MSP RAPID ADMS Suite User Guide v1 0 Page 4 Mode Structure For detail navigation please refer to the Operator Manual The diagram below describes the different modes of the NET and key operations for navigating between them Managing data functions are contained in Memory mode Basic mode Meas mode Navigable with tabs K gt 52 Display Functions A fede Cem EE pz 90 37 28 5 Be mg 324944 52
19. ker MSP RAPID StarPro Using USB Dongle License Key Launching RAPID ADMS Software without license a notification window will be displayed X Protection device not found Please connect device and try again Insert the RAPID USB Dongle key in order to use the full feature of Rapid PC If RAPID PC is to run on demo mode click on cancel r m ii Do you wish to run RAPID PC in lite version Lite version only allows WE maximum of 5 prism points and 1 monitoring cycle Continue An option to the user will be displayed whether to continue on Demo mode or to exit application Note Only RAPID PC can run on demo mode MSP RAPID DataChecker MSP RAPID SiteComs MSP RAPID OffComs MSP RAPID StarPro cannot run on demo mode Doc Ref No MSP RAPID ADMS Suite User Guide v1 0 Page 49
20. ll out the necessary settings for the Project a Raw 153 or proces KI may be used to create reference file Project Stations separate by comma ence File Directions dx dy SE Multiple recipients may be entered for each alarm trigger separate by commal Email Recipients Trigger 1 Trigger 2 Trigger 3 Trigger 1 Trigger 2 Trigger 3 Doc Ref No MSP RAPID ADMS Suite User Guide v1 0 Page 40 Project Input the Project Name Station Input the Project s Stations one or more station can be input Station names should be separated by coma Reference File Import the reference file TB3 file or processed PTS data can be imported Once the Reference file was successfully loaded Reference file will be shown on the right panel of the application Directions Users can choose which directions should be processed by StarPro dx dy dz Email Recipients Input the list of emails that will be notified whenever a trigger alert was reached Multiple emails can be input separated by coma Click on Test Button to verify if the email can be sent successfully SMS Recipients Input the phone numbers that will be notified wherever a trigger alert was reached SMS Alert will contain the Project Name Date Time Monitoring cycle Point name which reached the trigger alert and the value Click on Test Button to verify if the SMS can be sent successfully 7 1 3 Editing the Reference File On the liste
21. nie MSP RAPID ADMS Suite USER GUIDE Monitoring Solution Providers Pte Ltd 33 Ubi Ave 3 Vertex 05 31 Singapore 408868 Tel 65 6747 9766 Fax 65 6458 0824 Email enquiry mspsystem com Sales sales mspsystem com DISCLAIMER This document is Copyright 2008 by the Monitoring Solution Providers Pte Ltd MSP retains full copyright ownership rights and protection in all m aterial contained in this document You may use this document for your own purposes You may distribute this document to other persons provided that you attribute the document as having been generated by MSP and that the document is available free of charge on the MSP WebPro Web site Though MSP believes reasonable efforts have been made to ensure the accuracy of the information contained in this document it may include inacc uracies or typographical errors and may be changed or updated without notice It is intended for discussion and educational purposes only and is pro vided AS IS WITHOUT WARRANTY OF ANY KIND AND RELIANCE ON ANY INFORMATION PRESENTED IS AT YOUR OWN RISK In no event shall MSP be liable for any direct indirect punitive incidental special or consequential damages or damages for loss of profits revenue data down time or use arising out of or in any way connected with the use of this document or performance of any serv ices whether based on contract tort negligence strict liability or otherwise If you are dissatisfied with any portion of
22. nstrument NETOSAX v ZC Enabled v HA Fee Mode Easting m 30000 000 Battin iin 30000 000 Interval hrs An 2 Start Time 0 00AM RL m 100 0000 BREN ies O 0000 2 Temperature C Pressure hPa Prism Constants Reference mm Monitoring mm Connection mm 2 0 4 Custom mm oo Start Time 01 00 AM 05 00 AM 09 00 AM 01 00 PM 05 00 PM 09 00 PM D b Oo T C C C B Cy C Output File Path Backup File Path C Program Files RAPID ADMS Rapid B ackup Station Setting Options Project Name Input the Project Name Project may be consisting of Letters and Numbers Station Name Set the station name by default station name should start with STN Serial Port Set which COMPORT will the instrument be connected Refer to the PC configuration for the COMPORT numbering Baud Rate Sets the communication rate between the computer and the Total Station PC and the Total Station should have the same baud rate Default baud rate is 9600 Instrument Choose which model of Total station to be used Netim ll Net05 Net1 MSO5A MS1A Auto Launch Choose whether the RAPID PC will automatically run in case of PC was rebooted Doc Ref No MSP RAPID ADMS Suite User Guide v1 0 Page 22 Easting and Northing Input the X and Y coordinated measurement is in meters RL Reduced Level default value is 100m Orientation Used when doing a resection default value is 0 0000 Temperature and Pressure Varies depends on
23. o return to the Config Menu ul Ce Doc Ref No MSP RAPID ADMS Suite User Guide v1 0 Page 7 1 2 2 Instrument Configuration Setting Check or change the following instrument configuration as listed below Power off No Power Off Remote No Backlight Recticle on 2 Backlight Normal Auto Backlight off No Key Backlight On Inst contig Power off Power offfRemote No Backlight Reticle on i Backlight Mormal Auto Backlight Off No Key backlight Or Recticle 3 EDM ALC Free Beep Off Remote PWR On Yes Color Auto Touch Panel On Doc Ref No MSP RAPID ADMS Suite User Guide v1 0 Page 8 Inst config EDM ALC Prism check Beep Remote PYR On Color Touch panel Press OK to return to the Config menu 1 2 3 EDM Setting Configuration EF 2 Inst EEn SE Customize C 3Inst cons 3 Inst cons 9 8 Password 8 Password kr 4 EDM 9 Motor Bom ER Check or change the EDM configuration setting as listed below Doc Ref No MSP RAPID ADMS Suite User Guide v1 0 Page 9 EDM configurations Dist mode Reflector Prism H Prism const oom Aperture 5mm lum hold Ligt H EDM Menu Dist mode Fine S Reflector Prism Prism Const 0 0 mm Aperture 58 mm Illum hold Light Light 3 Light Pattern Blink EDM configurations Temperature Pressure Doc Ref No MSP RAPID
24. ofessional or later e 256MB of RAM 512MB recommended e 400GB of available hard disk space e Atleast 1 PCI Com Port e USB 2 0 port for licensing dongle e Minimum 800x600 Recommended 1 024 x 768 or higher e CD ROM drive for installation Doc Ref No MSP RAPID ADMS Suite User Guide v1 0 Page 18 3 0 MSP RAPID PC 3 1 Installing RAPID PC To Install RAPID PC A CD DVD ROM is required for the RAPID Installation CD 1 Once the RAPID ADMS Installation CD is inserted to the CD DVD ROM the RAPID ADMS Installation Wizard will automatically will be displayed RAPID ADMS Suite InstallShield Wizard Welcome to the InstallShield Wizard for RAPID ADMS Suite The InstallShield Wizard will install RAPID ADMS Gute on your computer To continue click Next Click on Next to continue for installation or Cancel to abort installation 2 Tick the button Software Licensing Agreement Then Click on Next button to Continue x RAPID ADMS Suite InstallShield Wizard BUE MSP Software License Agreement This document constitutes an agreement between Monitoring Solution Providers MSP and you Customer regarding Customer s use of this software the Software under the following terms and conditions This Agreement licenses Software to Customer and is not for the sale of Software or any other intellectual property All rights not expressly granted under this Agreement are reserved by MSP By installing copying
25. ould match the ouput folder of the RAPID Offcoms output file path Backup File Path Sets where RAPID DataChecker will back up a copy of rpd files Click OK button 6 1 2 Adding new station Click on Station Menu gt Add Station Doc Ref No MSP RAPID ADMS Suite User Guide v1 0 Page 35 e DataChecker ER File Station View Help PRS EDIT STATION ep TRAINING FILE T w WW SD 10 0 Project i Station A ENRL 10 0 B oint Name Prism Alias Prism Constant Horizontal Angle SREFO1 SREFO1 0 0 307 94680 SREFO2 SREFO2 3930 SREFOS3 SREFOS3 kl kl v S SR SR E S vE 5 B s S B s Ms S S S Ms S B s S vE 5 Ms S S E S Ms S B s S Project Name Input Project Name It should match the project name configured on RAPID PC Station Input the Station name It should match the Station name configured on RAPID PC Training Import the Training file generated by the RAPID PC By default training files are located at C Program Files RAPID ADMS Rapid training of the Site PC Training files may be in ini or txt format Imported training file will be shown on the right side panel Displacement Limits Output Path Set where the checked data will be saved Dataln folder of the RAPID StarPro is preferred for RAPID StarPro processing C Program Files RAPID ADMS StarPro Datain Maximum of 3 output path can be set Other Commands File gt Start Stop Start or Stop the RAPID Datachecker for pro
26. t Excel 29998 8502 29997 8469 113 8208 30016 024 2 3 53 856 30016 0317 29913 541 113 8591 30000 8244 30001 9244 K 30000 8243 30001 9244 Doc Ref No MSP RAPID ADMS Suite User Guide v1 0 Page 43 7 2 Reports 7 2 1 Generating Reports Note Microsoft Excel is required for viewing reports 1 Right click on a data or highlight multiple data choose the type of report to generate Daily Profile Daily profile report shows the following image vine O hanges in Y at RAPID STN1 XYZ from 18 Feb 11 to Gs Feb 11 and Daily Reading een from Cycle 1 to7 Changes In Y mm Doc Ref No MSP RAPID ADMS Suite User Guide v1 0 Page 44 Cycle Profile Cycle profile report shows the following image Changes in Y at RAPID STN1 XYZ004 from 18 Feb 11 to 18 Feb 11 and from Cycle 1 to 7 D OD Oo 4 J e 7 a TT REE 445s amp amp TEE E riir Doc Ref No MSP RAPID ADMS Suite User Guide v1 0 Page 45 History Report History report shows the following image Changes in Yat RAPID STN1 xX 2004 from 18 Feb 11 to 18 Feb 11 and from Cycle 1 to 7 Doc Ref No MSP RAPID ADMS Suite User Guide v1 0 Page 46 Generated Reports are listed on the right side panel of the application RAPID 18 Feb 1171 Start 18 Feb 17 End RAPID 18 Feb 1171 Start Fa 18 Feb 11 End 3 Ee i 18 Feb 11 St
27. this document or with any of these terms of use your sole and exclusive remedy is to discontinue using this document Doc Ref No MSP RAPID ADMS Suite User Guide v1 0 Table of Contents AG EELER EE 3 bie TER SEE MS en i a A N E E Er S 3 L2 Seuns Onhe ee 5 1 2 1 OBS CTV IO EE 6 1 2 2 Instrument Configuration Setting ics scctecsncessceapscsetsesseawnnedees eatansengelbiaaaneenacsiceeenseatesstumnenedessbertes taasssdantorencceaey 8 ka GE RT 9 1 2 4 ENEE 11 kaas Uo E 13 t26 ee e 14 LO MSP RAPID ADMS ee 18 Eltere 18 SS 7 MSP RARID acre Er eee Eee 19 sE TE ARARO CE ES E ee ee 19 Del e ENK PC a arses SEE ES SEES E E E A 22 33 RAPIC PC Command Dee 24 3 4 RAPID PC Monitoring EE ee 27 sA Howo De e180 8 1 gg en ER 27 SAd Howto stat e e e 27 o RAPIDPE Sha ET ESS SEE ERE 28 NR TE ER ECON Er ES EEG 29 Al serene up MSP RAPID i Co a 4 rare EERE ERA ANE ERR AEAN E EEE AEA ANEETA 29 4 2 RAPID SiteComs Workflow ceeeeecccceecceceeeeeeneeeeeeeeeeeeeeeeeeeaaeeeeeeeeeeeeeeeeeeeaaeaaeeeaeeeeeeeeeeeeeaeaaaaaaaaaeeeeeeeeeeeeeaeeaags 31 VEE ENTREE 32 zi Seneu MSP RAPID OFC E 32 5 1 1 Configure RAPID OffComs for receiving remote data 32 TA ed 0 e E E E ace ee ee er cee SENERE 32 SC MSP RAPID REN de erences rere re mere eee eet ener nan errant naar ner rr ere ere er etre 34 BO dE EE 35 6 1 Setting up MSP RAPID DataChecker W W Wu u u u dvdssssrrerreeeeeren enn rrreseennn EEEENN NEEN ren rens n nens 35 Doc Ref
28. to copy the Training file for RAPID Processing See the Section 6 0 RAPID PC Monitoring Procedures for the Steps on how to train the points Orientation Menu len Monitoring view J Mode 3 o Reset Count Chr Total Station Re Orientation is normally done whenever Total Station is moved or changed When a Total Station is placed or was changed It is required for the Users to do Re Orientation in order for the Total Station to monitor known points Also for Resection Users are required to do resection when Total Station is moved to a different location Monitoring Menu Enable Cycle Timer Chrl 5 UI Start Monitoring Chrno Enable Disable Cycle Timer Enable or Disable the timer countdown for the next monitoring cycle Cycle timer is shown on the lower left side corner of the application Start Stop Monitoring Sends command to the Total Station to start or to stop monitoring Open Data Opens a data reading from the selected cycle on the left panel RAPID PC will open tb3 file into a notepad Delete Cycle Delete a data from the selected cycle on the left panel of the application Doc Ref No MSP RAPID ADMS Suite User Guide v1 0 Page 25 Note Monitoring Data are RAPID PC Raw data file name syntax STN PROJECTNAME DD MM YYYY Cycle if Epoch ff rpd Where STN Project Station Number PROJECTNAME Project name DD Date MM Month YYYY Year Cycle if Monitoring Cycle Epoch Epoch File history
29. ument for entire monitoring process Dictates start and end time for monitoring location and method to observe in accordance to User requirements MSP RAPID PC measures data and tabulate results in easy to view and understand readings MSP RAPID SiteComs is a communication module for RAPID ADMS Suite that is capable of sending data generated by RAPID ADMS from Site location to Office RAPID SiteComs is installed together with MSP RAPID PC GMS GPRS UHF parameters can be set for communication media RAPID SiteComs auto scan and send data in the Dataout folder MSP RAPID OffComs is a communication module for RAPID ADMS Suite that is capable of receiving data sent by MSP RAPID SiteComs MSP RAPID OffComs is installed together with MSP RAPID DataChecker and MSP RAPID StarPro GMS GPRS UHF parameters can be set for communication media RAPID OffComs auto scan incoming data and save the received data in the Dataln folder MSP RAPID DataChecker automatically scans raw data from the incoming path folder to filter and eliminate bad data for processing MSP RAPID StarPro automatically calls out the least square adjustment processing engine for calculation then it generates reports and tabulates measurement data into graphical view which users can modify for their customization MSP RAPID Starpro sends out alarm notification via SMS email and through alarm siren System Requirements Minimum System Requirements e Microsoft Windows XP Pr