1. the figures will start blinking indicating that the current temperature setpoint is being displayed use the right hand or left hand switches to increase or decrease the displayed hysteresis within the adjustment range 0 C 10 C after ca 4 sec the display will stop blinking indicating that the preset temperature has been stored The display will return to displaying the current temperature as measured by the sensor d adjustment of response speed for viewing the response speed setpoint press and hold the left hand switch under the display for ca 5 sec the figures will start blinking indicating that the current temperature setpoint is displayed use the right hand or left hand switches to increase or decrease the displayed response speed within the adjustment range 1 64 after ca 4 sec the display will stop blinking indicating that the preset temperature has been stored The display will return to displaying the current temperature as measured by the sensor e controller operation EUROSTER 1100M is a PI proportional integral controller which maintains the preset temperature by opening and closing the valve When the temperature measured by the sensor is within the preset range the relays are off With the two user defined settings hysteresis and response speed it is possible to customise the control algorithm to the building characteristics Hysteresis use this setting to reduce switching frequency in systems with
2. high variations of system water temperature Response speed use this setting to customise the control speed according to the building characteristics For large exceedings and oscillations of temperature around the setpoint the response speed should be decreased thus increasing the response time If the time to reach the preset temperature is to long the response speed should be increased Relation between the setpoint value and the response speed NORMAL TTA MIN l 16 64 dynamic adjustment value EUROSTER 1100M USER MANUAL 4 DATA SHEET ow Th temperature setting range temperature measurement range heating system hysteresis turn on turn off difference response speed supply voltage max current 10 C 80 C 1 C 99 C 0 C 10 C 1 64 230V AC 50 Hz 6A AC
3. EUROSTER 1100M USER MANUAL 1 EUROSTER 1100M 1 FUNCTION EUROSTER 1100M is a processor based unit used for controlling the operation of actuated 3 way valves equipped with limit switches installed on hydronic heating systems In heating systems supplied by a coal fired boiler EUROSTER 1100M controls the operation of the valve and maintains the return water temperature at a constant level With the return temperature set at an optimum level the boiler does not sweat during heating up of system water Moreover this has a positive effect on the boiler life The temperature is measured by a digital sensor installed on the return pipe EUROSTER 1100M is equipped with ANTI STOP system to prevent seizure of the valve in idle periods Throughout the non heating season it automatically cycles the valve for 30 seconds every 14 days with the temperature below 30 C For this function to be operational the thermostatic controller must not be switched off at the end of heating season Valve status indication opening movement Valve status indication closing movement Hysteresis and temperature adjustment Response speed temperature On off mains switch Temperature sensor Valve supply 230 V AC Controller supply 230 V AC Sow Se 2 INSTALLATION DANGER Prior to installation by a qualified electrician make sure that the unit has been disconnected from power supply to avoid the risk of electric shock Units with
4. emperature should not exceed 40 C 3 OPERATION a start up set the left hand switch to position I upon energising all the segments of the display light up for 2 seconds the current temperature measured by the sensor is displayed and the controller operates according to the factory preset values temperature of system water 40 C hysteresis 1 C neutral response speed 16 b description of display functions display continuously on current temperature measured by the sensor blinking display setpoints of temperature hysteresis response speed red LED on the upper one mixing valve status indication opening movement green LED on the lower one mixing valve status indication closing movement c setting the temperature and hysteresis for viewing the temperature setpoint press the right or left hand switch under the display the figures will start blinking indicating that the current temperature setpoint is being displayed use the right hand or left hand switches to increase or decrease the displayed temperature within the adjustment range 10 C 80 C after ca 4 sec the display will stop blinking indicating that the preset temperature has been stored The display will return to displaying the current temperature as measured by the sensor EUROSTER 1100M USER MANUAL 3 for viewing the hysteresis setpoint press and hold the right hand switch under the display for ca 5 sec
5. mechanical damage should not be installed a mounting of the controller the controller is fixed directly to the wall or to any other support with two screws plastic plugs c w screws are part of delivery the cables extending from the controller are fixed to the wall with cable clips EUROSTER 1100M USER MANUAL 2 b mounting of the sensor the sensor is NOT intended for immersion in liquids and installation on flues between the boiler and chimney install the sensor on a bare return pipe as close to the boiler as possible secure the sensor on the pipe by tightening the supplied buckle clip NOTE As a recommendation the inlet pipe should be provided with thermal insulation on the section between the boiler and the temperature sensor If the central heating system is supplied by both a coal and a gas fired boiler the temperature sensor should be installed at the meeting point of the two outlet pipes and insulated c connecting of the power supply cable to the valve connect the black wire valve opening to terminal L connect the blue wire common to terminal N connect the brown wire valve closing to terminal L d check up of connections make sure that the wires have been connected as indicated e connection of the controller upon securing the cables against accidental pullout connect the power supply cable to a 230V 50Hz grounding socket NOTE At the mounting location of the controller ambient t
Download Pdf Manuals
Related Search
Related Contents
Pose-prothèse TONN / NOVATECH Stent Applicator Anthem™ - Sante International SA PDFをダウンロード VALORE VS-1204 Instructions / Assembly Towards a unifying CSP approach for hierarchical verification of SC200C Scope Clock Board Kit Assembly and User Manual D EXCAVADORAS Manuel d`utilisation チラシ表 - 三重県地方自治研究センター Copyright © All rights reserved.