Home

MG2, MG2-XT, and MG2-DL - mg-2.ru

image

Contents

1. Internal Data Logger The powerful MG2 DL internal data logger allows you to store recall and transmit 31 000 thickness measurements with their identification codes With the optional live waveform mode the gages can also store 1 300 waveforms with thickness measurements All stored information can easily be transferred to your computer for statistical analysis Alphanumeric Identification Codes You can assign an eight character file name and up to ten alphanumeric ID numbers to each stored thickness measurement Each thickness measurement is fully documented with parameter information such as material sound velocity transducer data and measurement mode ERRRERARARERRALEH EUS Ep EI EE DEP I EP Si EE E E E E P o E e SO a a a a a a a ee a This printed measurement report contains measurement ID and other parameters GageView The optional GageView interface program is a Microsoft Windows based applica tion that collects creates prints and manages data from the MG2 DL e Create datasets and surveys e Download and upload thickness surveys to and from the gages Onboard Statistics Calculator The MG2 DL internal data logger features an onboard statistical calculator to gener ate reports that can be directly transmit ted to your printer STATSY __ 29 1 3 0 0111 1 1657 REPEAT lt gt to select button Then Press ENTER or gt ENTER
2. layer using multiple backwall echoes Auto Echo to Echo Manual Echo to Echo Live A scan mode only that allows e Gain Adjust e Extended Blanking e Echo Blanking jeer ttt Extended Echo Blank Blank vey ines my i j 1 Fap _ My T i Wa i re ES ciel Bi rm a od i a EFT B scan Corrosion Mapping The MG2 XT and MG2 DL offer the B scan feature that converts live thickness measurements into cross sectional images on the display This standard feature is a very helpful in applications where reviewing how the thickness changes over distance is necessary When a user activates the B scan feature a cross sectional thickness representation appears as soon as the transducer makes contact with the material The Freeze Min function can be used to display the minimum thickness of a scanned area Up to 1 300 B scan images can be stored in the MG2 DL s data logger High Temperature Surfaces The MG2 XT and MG2 DL are ideally suited for making stable thickness mea surements on hot material surfaces up to 500 C 932 F with the D790 series transducers D790 D790 SM D790 RL and D790 SL The Zero Compensa tion feature of the MG2 series enhances the accuracy of measurements on hot surfaces by compensating for temperature changes in the transducer delay line due to thermal drift D790 Transducer www olympus ims com Data Collection for Fast and Reliable Documentation
3. 20 in to 25 000 in Thickness range depends on material transducer surface condition temperature 0 508 mm us to 18 699 mm us 0 0200 in us to 0 7362 in us Measurement mode Thickness range Material velocity range e Cross sectional B scan e DB grid MG2 DL only e Digital thickness readout e A scan or Waveform optional LOW 0 1 mm 0 01 in STANDARD 0 01 mm 0 001 in Display modes Resolution Standard rate 4 measurements per second Measurement rates Fast rate 20 measurements per second Measures and recalls the minimum or maximum thickness at 20 measure Min Max mode ments per second Freezes the display to instantly capture critical thickness Minimizes trans Freeze MOde ducer couplant liftoff error and facilitates high temperature measurements Automatically recognizes the listed types of Panametrics transducers Automatic probe recognition Adjusts internal parameters and corrects V path errors Zero compensation Compensates for transducer temperature and zero offset Display Hold Blank mode Backlight Receiver bandwidth Holds or blanks the display after measurements Electroluminescent display Selectable as On or Auto On 1 MHz to 18 MHz 3 dB Metric English mode Metric or English units Display languages English French German Spanish Italian and other custom languages Three 3 AA alkaline batteries 150 h of typical battery life 30 h continuous use with backlight Battery Op
4. Aa 11 00 1 00 to 500 00 90 to 500 U8800353 D790 RL ee 0 434 0 040 to 20 000 5 to 932 U8800330 D790 SL U8450008 aa U8800331 a T 00 to aan ress to ae i 1 AA o 00 to a to D792 U8450012 Seah 7 20 0 50 to 25 00 0 to 50 Potted D793 U8450013 0 283 0 020 to 1 000 32 to 122 n 0 75 to 50 00 O to 50 D797 U8450016 22 90 3 80 to 635 00 2010400 Potted D797 SM ao 0 900 0 150 to 25 000 5 to 752 LCMD 316 5D U8800355 D7226 U8454013 8 90 0 71 to 100 00 20t0 150 Potted D798 LF o 9 0 350 0 028 to 4 000 5 to 300 D798 U8450018 7 20 0 71 to 100 00 20t0150 Potted D798 SM U8450020 0 283 0 028 to 4 000 5 to 300 Pet 316 5 U8800357 R E to 20 to 150 5 10 1 00 to 19 00 0 to 50 MTD705 U8620225 CECAT oala aa 750 e on a aa D7906 SM U8450005 E 11 00 1 00 to 50 00 0 to 50 aoas 316 5L U8800358 D7906 RM U8450025 0 434 0 040 to 2 000 32 to 122 LCMD 316 5N 316 5N U8800647 oT eo O to 50 tt Dependent on material transducer type surface conditions and temperature Full range may require Gain Adjust Maximum temperature with intermittent contact only t Stainless steel cable available consult Olympus NDT for details tt Transducers used with THRU COAT technology D792 D794 m D791 RM p MTD705 O F D7906 SM www olympus ims com MG2 Specifications Pulse echo with dual element transducers 0 50 mm to 635 00 mm 0 0
5. OLYMPUS Your Vision Our Future h OLWMPUS OLYMPUS MG2 MG2 XT and MG2 DL These small affordable ultrasonic thickness gages are primarily designed for inspectors and maintenance engineers responsible for measuring the remaining thickness of inter nally corroded pipes tanks and other metal structures Lightweight and ergonomically designed for easy one hand operation these gages are cost effective measurement solu tions for many applications requiring quick inspection of materials suspected of metal wall thinning Olympus NDT is known worldwide as a manufacturer of innovative state of the art ultrasonic testing products We also believe that our customers deserve thickness gages that truly combine quality accuracy and ease of operation at affordable prices We have accomplished this with three rugged models the MG2 MG2 XT and MG2 DL Each model offers a range of practical mea surement features to solve a wide variety of thickness gaging problems Even better they all share being manufactured by a company taking pride in having the best customer sup port network in the industry CORROSION THICKNESS GAGES MG2 Series a Features Measurements from one side Ultrasonic thickness gages make instant digital measurements by transmitting sound into a material from one side making it unnecessary to cut the corroded part Lightweight and pocket size These handheld gages ar
6. Statistic report showing minimum and maximum values 7 A 4 E KETE 0 0735 0 0666 0 0451 REPEAT to select button Then press ENTER or sd gt gt ENTER Statistic report showing Hi Low alarms mean median and standard deviation 249 1 13 8 A color coded grid easily flags out of tolerance thickness conditions e Edit stored data e View dataset and survey file information including thickness readings gage configuration values and transducer configuration values programs Export surveys to spreadsheets or other GridView The GridView feature only available with the MG2 DL allows viewing stored thickness data in a Grid or Expanded Liner format It also allows users to easily review and navigate saved thickness data in a row and column grid by simultaneously displaying the grid positions with the current thickness measurement a4 __ 66 8 3 77 es Pe e Collect screen captures e Printing reports such as the Thickness Setup Table Statistics and Color Grid e Upgrade the operating software e Drag to Microsoft Excel spreadsheets Transducers with Automatic Probe Recognition Each MG2 series gage is compatible with our complete line of easy interchangeable dual element transducers that vary in frequencies diameters and temperature capabilities to deal with virtually every application D790 aoe D790 SM me
7. e je je je je e je Se 2 ee 2 j2 je 2 MG2 L2 e je je je e j2 je 2 2 Practical Measurement Features MG2 XT and MG2 DL Only THRU COAT Through this patented technology the gage can simultaneously display the thickness of the coating and the true metal thickness using a single backwall echo Each measurement is adjusted for their calibrated material sound velocity THRU COAT measurements are made with D7906 SM and D7908 transducers Tanke Hau Norn THR THRU COAT Thickness Metal Thickness Live A scan with Waveform Adjust This optional Live A scan mode allows users to view the ultrasound waveform or A scan directly on the gage s display verify the thickness measurement and make manual adjustments to gain and blanking settings to maximize measure ment performance in challenging applica tions This helpful option features Manual Gain Adjust Extended Blanking Echo Blank Range and Delay Gain Adjust This feature is very helpful when mak ing measurements on sound attenuating materials such as cast metals e Preset Gain Adjust to High Low or Standard e Manual Gain Adjust can be configured in 1 dB increments Live A scan mode only Extended Blanking Allows blanking unwanted echoes due to material surface noise caused by rough or irregular surfaces Live A scan mode only 4 Echo to Echo The gage displays the true metal thickness and ignores the thickness of the coating
8. e small enough to fit in a toolbox or inside your pocket They are ideal for quick inspections in hard to reach areas Intuitive color coded keypad Allows you to directly access many important measurement features saving you time Strategically located keys are grouped by color for easy recognition Large backlit LCD The display s large numerals make it easy to read thickness measurements You can also easily view the electroluminescent backlit display in total darkness or bright sunshine The MG2 XT and MG2 DL are available with THRU COAT B scan and optional Live A scan with Waveform Adjust 920 039F EN Choose From Three Units MG2 The MG2 offers many basic features such as the Min Max mode to measure and recall the minimum thickness at a fast 20 measurements per second the Freeze mode to instantly capture critical thicknesses and the Zero Compensation mode to ensure optimal transducer performance Several other features make this handheld gage affordable for quick spot measurements MG2 XT The MG2 XT is equipped with the same features as the MG2 but enhanced with B scan Gain Adjust auto sensitivity optimizations Echo to Echo THRU COAT Differential mode Hi Low alarms and the optional Live A scan to provide you with more measurement capabilities in tough applications This gage is ideal when making thickness measurements on coated or painted surfaces MG2 DL The MG2 DL is the mos
9. erating time Low battery indicator Continuously indicates battery status Battery saver Auto power off Continuous on Splash proof impact resistant case Sealed color coded keypad with tactile and audible feedback As prescribed by MIL STD 810E 511 3 procedure 1 Operating temperature range 10 C to 50 C 14 F to 122 F Dimensions W x H x D 84 0 mm x 152 4mm x 39 6 mm 3 31 in x 6 0 in x 1 56 in Weight 340 g 12 oz IP65 rated Hazardous area operation Measurement features THRU COAT Echo to Echo Gain Adjust Extended Blanking Differential Allows the normal measurement sensitivity to be automatically increased or decreased depending on the thickness and material noise level Auto sensitivity gain optimization Alarm mode Programmable Hi Low set points with audible and visual indicators Optional Live A scan mode allows viewing of ultrasound waveforms or A scan directly on the display Features Manual Gain Adjust Extended Blanking Echo Blank Range and Delay Live A scan with Waveform Adjust Identifies stores recalls clears and transmits thickness measurements and Data logger gage configuration information through the USB port Over 31 000 thickness measurements or 1 300 waveforms with thickness Capacity measurements with waveform option Each saved thickness reading is fully documented with measurement status flags and a configuration number identifying parameters such as the veloc ity
10. n MG2 DL MG2 DLRETRO U88780206 Convert an MG2 into an MG2 DL MG2 WF U8147004 Live A scan with Waveform Adjust for the MG2 XT and MG2 DL only not available for the MG2 For additional accessories such as holders wands and couplants please consult Olympus NDT OLYMPUS NDT INC is ISO 9001 14001 certified IRIA FSC Mixed Sources Product group from well ma fore t ay o sources A recycled wood or fiber Cert no wow fr O 1996 Forest trewanditep Coar il CE
11. t advanced model of the MG2 series gages It packages all the features of the MG2 XT and comes with a versatile file based alphanumeric data logger that uses incremental sequential 2D Grid and Boiler format files Using the optional GageView interface program you can also transfer gage data to and from your computer DISPLAY L A AECHLZS4F DIA GHISTD Horm Ad EEE COUPLE to thick Standards Tess ENTER JENTER MEAS M COMPARISON CHART Thickness range 0 5 mm to 635 0 mm 0 02 in to 25 00 in Thickness display resolution up to 0 01 mm 0 001 in Automatic probe recognition High temperature capabilities Fast measurement rate of 20 per second Min Max mode Freeze mode Zero Compensation mode Display Hold Blank Inches Millimeters mode Live A scan with Waveform Adjust optional Gain Adjust B scan Auto Sensitivity Gain Optimization Differential mode Hi Low alarm THRU COAT Echo to Echo Internal data logger 2D Grid GridView GageView interface program optional Plastic carrying case File name Freeze mode Differential mode Hi Low alarm Gain adjust Measurement rates Previous thickness Current measurement Battery life Available keys A B C D E E G H l J K L 1 Features of the MG2 XT and MG2 DL 2 Features of the MG2 DL OL RAPS User Help oa De MG2 DL AN Le je e e je je e je je j2 2 je j 2 2 j2 j2 2 2 je 2 2 MG2 XT L
12. transducer etc Stored data documentation File names and ID codes Eight character file name and 10 character alphanumeric identification code File templates Incremental Sequential 2 D Grid Boiler and Manual from PC OLYMPUS NDT INC 48 Woerd Avenue Waltham MA 02453 USA Tel 1 781 419 3900 12569 Gulf Freeway Houston TX 77034 USA Tel 1 281 922 9300 OLYMPUS NDT CANADA INC 505 boul du Parc Technologique Qu bec Qu bec G1P 4S9 Tel 1 418 872 1155 1109 78 Ave Edmonton Alberta T6P 1L8 OLYMPUS www olympus ims com MG2_EN_201203 e Printed in the USA Copyright 2012 by Olympus NDT All specifications are subject to change without notice info olympusNDT com All brands are trademarks or registered trademarks of their respective owners and third party entities Standard Packages Model MG2 digital ultrasonic thickness gage wrist strap test bar couplant user s manual plastic carrying case with MG2 XT and MG2 DL models and a two year limited warranty Standard packages include a dual element transducer Optional Accessories 2214E U8880014 5 step test block English units 2214M U8880016 5 step test block metric units MG2 EW U8902946 Extended warranty MG2 RPC U8764047 Protective rubber boot GageView USB U8140074 PC interface program for the MG2 DL MG2 XTRETRO U8147008 Convert an MG2 into an MG2 XT MG2XT DLRETRO U8147009 Convert an MG2 XT into a

Download Pdf Manuals

image

Related Search

Related Contents

Jacuzzi 7260 Hot Tub User Manual    Everbilt ZE00804 Use and Care Manual    Samsung Galaxy S4 Manuel de l'utilisateur  moisture meter - CONRAD Produktinfo.  nov-dec2012 (link is external)  Insignia NS-19LCD User's Manual  ACS800 Programming Manual  2 Liability NEDERLANDS 3 DEUTSCH 9  

Copyright © All rights reserved.
DMCA: DMCA_mwitty#outlook.com.