Home

BCM-E100 User`s Manual - Blue

image

Contents

1. 12 PD13 GPIO 13 PD10 GPIO 14 PD11 GPIO 1 16 PIN ASSIGNMENT 3 CNI Description 8 Pins Pin Signal Name Function 1 VCC Power 3 3Vdc 2 GND GND 3 TRST JTAGE 4 TCK SWCLK JTAGE 5 TDI JTAGE 6 TDO SWO JTAGE 7 TMS SWDIO JTAGE 8 RESET Reset 1 17 JP1 PIN ASSIGNMENT System reset to default if JP1 short over 5 sec www bluecomm com tw Copyright 2012 Reserved by Blue Comm Electronics Co Ltd BLUE BCM E100 User s Manual m 1 18 ETHERNET PORT PIN PIN ASSIGNMENT RJ45 www bluecomm com tw Copyright 2012 Reserved by Blue Comm Electronics Co Ltd 11 BLUE BCM E100 User s Manual 2 GETTING STARTED 2 1 INSTALL THE E100 MODULE ONTO THE E100 EVALUATION BOARD Before using the E100 evaluation board with the module be sure to disconnect the power supply network and serial device Please refer to the figure below When attaching the module to the evaluation board make sure the module is securely installed on the evaluation board After the module is installed connect the power supply network and serial device to the evaluation board a tiit ilii me fuf Older ST UART3 TK P08 PBO ADCI2INB UART3 RXvP09 pas A0ci2INe le jee E HanRun HR911105A www bluecomm com tw Copyright 2012 Reserved by Blue Comm Electronics Co Ltd 12 BCM E100 User s Manual 2 2 SELECTING THE SERIAL INTERFACE The
2. QJ RS M JD mr i 2 00 1 85 4 81 clus www bluecomm com tw Copyright 2012 Reserved by Blue Comm Electronics Co Ltd 7 BLUE BCM E100 User s Manual Dl 1 14 PIN ASSIGNMENT 1 Main Pins 20 Pins Pin Signal Name Function 1 UART3 TX PD8 Communication port TX 2 UART3 RX PD9 Communication port RX 3 UART6 TX PC6 System reserve 4 UART6 RX PC7 System reserve 5 UARTI TX PA9 UART GPIO 6 UARTI RX PA10 UART GPIO 7 CANI RX PAI1 CAN GPIO 8 CANI TX PA12 CAN GPIO 9 SPI3 MISO PC11 SPI GPIO 10 SPI3 MOSI PC12 SPI GPIO 11 SPI3 CLK PC10 SPI GPIO 12 DCI CLK PB6 I2C GPIO 13 I2C SDA PB7 I2C GPIO 14 ADC12IN 12 PC2 ADC GPIO 15 ADC12IN 13 PC3 ADC GPIO 16 GND GND www bluecomm com tw Copyright 2012 Reserved by Blue Comm Electronics Co Ltd 8 BLUE BCM E100 User s Manual OMM 17 VCC Power 3 3Vdc 18 ADCI2IN 5 PAS ADC GPIO 19 ADCI2IN 6 PA6 RS458 Direction 20 ADC12IN 8 PBO ADC GPIO 1 15 PIN ASSIGNMENT 2 J1 Description 14 Pins Pin Signal Name Function I PD6 GPIO 2 PD7 GPIO 3 PD4 GPIO 4 PD5 GPIO 5 PD2 GPIO 6 PD3 GPIO 7 PDO GPIO 8 PDI GPIO 9 PD14 GPIO 10 PD15 GPIO 11 PD12 GPIO www bluecomm com tw Copyright 2012 Reserved by Blue Comm Electronics Co Ltd BLUE BCM E100 User s Manual
3. be sure the netmask and IP address are configured to allow hosts on the private network to access the module Note that by default the module is configured to use a private IP address www bluecomm com tw Copyright 2012 Reserved by Blue Comm Electronics Co Ltd 15 BLUE BCM E100 User s Manual 2 5 CONNECTING TO A SERIAL DEVICE To connect to a serial device for testing and development purposes the module should be installed on the evaluation board Be sure to select the serial interface you would like to use before you connect the evaluation board to the serial device Refer to the Selecting the Serial Interface section above when you are using jumper blocks to select the serial interface on the evaluation board The modules serial signals are routed to and from the RS 232 COM port on the evaluation board Use a serial data cable to connect the serial device to the COM port on the evaluation board SL EL YSOLLLGYH unyueH www bluecomm com tw Copyright 2012 Reserved by Blue Comm Electronics Co Ltd 16 i BLUE BCM E100 User s Manual om a 3 CHOOSING THE PROPER OPERATION MODE The following topics are covered in this chapter B TCP Client Mode ll MODBUS Gateway Mode 3 1 TCP CLIENT MODE 3 1 1 Using easy AT Command Host Server TTTTTTT ee 1 Raquesta comneaciion E100 2 Proceed with dataltransmission Serial TTL Customer Board www bluecomm com tw Copyright 2012
4. E100 module uses a standard TTL serial signal input However to make evaluation more convenient the evaluation board has built in two RS 232 interfaces Use a 16 pin jumper to select which serial interface is active C Accroding to n module type select whilch serial interface is ave 0 3 7 e 2 ELA n ood U RT3 TX PD8 PBO fIDC121N8 U RT3 RX POS P Ae amp Pr nocizine O i UART6 TK PC6 d HanRun E t enema O Fn5 ADC12INS O HR911105A chy VARTI TPN O TP44 www bluecomm com tw Copyright 2012 Reserved by Blue Comm Electronics Co Ltd 13 BLUE pi BCM E100 User s Manual 2 3 CONNECTING THE POWER Connect the 5 VDC power line with the evaluation boards USB mini jack If the power is properly supplied the power LED on the evaluation board D1 will show a red color until the system is ready 88 5 Lun SNIZI20V Qd www bluecomm com tw Copyright 2012 Reserved by Blue Comm Electronics Co Ltd 14 BLUE BCM E100 User s Manual rn 2 4 CONNECTING TO THE NETWORK To connect to the network for testing and development purposes plug the Ethernet cable into the RJ45 jack on the evaluation board If the cable is properly connected the LED will indicate a valid connection to the Ethernet as follows LED Color Meaning Right Green Link Activity does not blink when not transmitting blinks when transmitting When using a private IP address 192 168 xxx xxx
5. 1 When y 1 Turn on x TCP connection index When y 0 turn off x TCP connection index x TCP connection index y 1 connect y 0 disconnect www bluecomm com tw Copyright 2012 Reserved by Blue Comm Electronics Co Ltd 26 BCM E100 User s Manual BLUF COMM Command Response Description AT GET_TCP_STATUS x Connected Read TCP connection status x 0 1 OK Disconnect OK ERROR Command Response Description AT GET_TCP_DATA x TCP READ x 0 Read TCP data length 0 x 0 1 TCP READ x 5 1122334455 Read TCP data length 5 Data 0x11 0x22 0x33 0x44 0x55 ERROR Syntax format error AT SET_TCP_DATA x 3 ABCD OK Write TCP data length 3 EF x 0 1 Datt 0xAB OxCD OxEF www bluecomm com tw Copyright 2012 Reserved by Blue Comm Electronics Co Ltd 27 SU BCM E100 User s Manual MM ser s Manua COMI 5 2 AT COMMAND EX1 Step1 Select AT Command mode Blue Comm Electronics Overview Network settings System settings Update Settings Work mode AT gommand Mode X Alias Name 115200 N amp 1 Select AT Command Mode Admin Password 1234 erty 00A9 F 0xO4 AzQx0000 Connected 192 168 127 25 a 5 Step2 Open a Hyper Terminal lc 7 5 li COM2 115200baud Tera Term VT sih ER Sox File Edit Setup Control Window H TCP Profile Index 0 AT Comman
6. BCM E100 User s Manual www bluecomm com tw Copyright 2012 Reserved by Blue Comm Electronics Co Ltd BCM E100 User s Manual BLUE COMM 1 INTRODUCTIONS 0d enen aaeeaaea aea aaea aa aaua 4 1 1 GESCRIPTION uw en 4 1 2 FORM FACTOR EROR REA ERI RU da ERES ERE D Lee RI e Ev IR I SENE 5 1 3 SYSTEM INFORMATION das es eere tne on enero ane A See Es Eee YES soens 5 1 4 EthERNET INTERFACE isset esaet te eere es noe yR opa e pev on suae cr RE eT OE 5 1 5 SERIAL INTERFACE ies ee ao e ena eaa eae nee pee s ves E Ia sepsin oeii ia 5 1 6 SERIAL COMMUNICATION PARAMETERS pp 5 T 7 SERIAL SIGNALS crei re i vow eva a IE Ex RE VR NER EYE PX EN PEU FEY NY EE TERETE EEEa 6 1 8 GAO 6 1 9 SOFTWARE snes tere i vu roa EE ERR YA REN EVA X ERN VERE VERE TVER SEIN PE VERS EEEE 6 1 10 ENVIRONMENTAL LIMITS RN 6 1 11 POWER REQUIREMENTS RN 6 1 12 WARRANTY Dee eee nego oue ERE eue ue seges VESPA rao e EU s Te CU SPP E REK 7 1 13 DIMENSION se 7 1 14 PIN ASSIGNMENT 1 eei evertere o rie EIN PRAE PAR VERRE VAS VEN FEIN PP PP e DTE Ebr Eds 8 1 15 PIN ASSIGNMENT 2 i iere ein ed e a Ghee n au e Ee ea de e En Een o Pen ETES EEEIEE ads 9 T 16 PIN ASSIGNMENT 3 c eere ree ee a ye PER VW Ee REEN EV VR DE TRE CEN EYES UE 10 1 17 JP1 PIN ASSIGNMENT Senin nn des rarene seais 10 1 18 Ethernet port pin PIN ASSIGNMENT cssssssseeee eme meme emen 11 2 GETTING STARTED ceastcctss sa suse sa pesca Pea su Desa Po Ras po glaPDlsa P
7. Copyright 2012 Reserved by Blue Comm Electronics Co Ltd 30 BLUE BCM E100 User s Manual rm APPENDIX A WELL KNOW PORT NUMBERS This appendix is included for your reference Listed below are port numbers that already have a well established use These port numbers should be avoided when assigning a port number to your E100 module TCP Socket Application Service 0 reserved 20 FTP data 21 FTP control 25 SMTP 37 Time server 53 DNS 80 HTTP 502 MODBUS server UDP Socket Application Service 0 reserved 53 DNS www bluecomm com tw Copyright 2012 Reserved by Blue Comm Electronics Co Ltd 31 BLUE BCM E100 User s Manual 69 TFTP 161 SNMP 162 SNMP traps 9000 Device Search www bluecomm com tw Copyright 2012 Reserved by Blue Comm Electronics Co Ltd 32
8. Reserved by Blue Comm Electronics Co Ltd 17 BLUE BCM E100 User s Manual Li 3 2 MODBUS GATEWAY MODE Host Server Q Requesta comecten 2 Frossed wih dataltransmission Serial TTL Customer Board i m a a a a a a a 1 a Midi m m E B a a a a y 3 3 UDP MODE OPTION 3 4 TCP SERVER MODE OPTION www bluecomm com tw Copyright 2012 Reserved by Blue Comm Electronics Co Ltd 18 BLUE BCM E100 User s Manual e 4 CHOOSING THE PROPER OPERATION MODE The E100 supports several tools for configuring the module In this chapter we briefly describe the options available and appropriate situations for using those options The following topics are covered in this chapter Wi Utility console ll Web console www bluecomm com tw Copyright 2012 Reserved by Blue Comm Electronics Co Ltd 19 BLUE rem BCM E100 User s Manual 4 1 UTILITY CONSOLE Device Search Utility is designed for Windows and is mainly used to search for the E100 modules and for assigning IP addresses g Blue Comm Device Search V1 0 Alias Name IP Mode MAC IP Netmask Gateway MODBUS Gateway Static IP 00 04 A3 AB C9 57 192 168 127 253 255 255 255 0 192 168 127 254 Blue Comm 1 0 0 0 20131125173927 00 04 A3 AB C9 57 MODBUS Gateway Static IP 192 168 127 253 255 255 255 0 192 168 127 254 MODBUS Gateway 2400 N 8 1 www bluecomm com tw C
9. T SET_DNS1 16 OK Write DNS 1 IP address 8 95 1 1 ERROR Command Response Description www bluecomm com tw Copyright 2012 Reserved by Blue Comm Electronics Co Ltd 24 BCM E100 User s Manual BLUF COMM AT GET_DNS2 168 95 1 1 Read DNS 2 IP address OK AT SET_DNS2 16 OK Write DNS 2 IP address 8 95 1 1 ERROR Command Response Description AT GET_DNS2 168 95 1 1 Read DNS 2 IP address OK AT SET_DNS2 16 OK Write DNS 2 IP address 8 95 1 1 ERROR Command Response Description AT GET_NETMAS 255 255 255 0 Read subnet mask address A OK AT SET_NETMASK OK Write subnet mask address 255 255 255 0 ERROR Command Response Description AT GET_GATEWA 192 168 1 254 Read gateway address www bluecomm com tw Copyright 2012 Reserved by Blue Comm Electronics Co Ltd 25 HSU BCM E100 User s Manual KULI AT SET_GATEWA OK Y 192 168 1 254 ERROR Write gateway address Command Response Description AT GET_TCP_PR x 192 168 1 100 1234 OFILE x OK n ERROR Read Server IP and Port x TCP connection index AT SET TCP PRO OK FILE x 192 168 1 Write Server IP and Port ERROR x TCP connection index 100 502 x f0 1 Command Response Description AT SET_TCP_CON OK NECT x y ERROR x 0 1 y 0
10. TION PARAMETERS Data Bits 8 Stop Bits 1 Parity None Even Odd Flow Control None www bluecomm com tw Copyright 2012 Reserved by Blue Comm Electronics Co Ltd BLUE BCM E100 User s Manual D Baud rate 2400 4800 9600 19200 38400 57600 115200 230400 Kbps 1 7 SERIAL SIGNALS TTL TXD RXD GND TTL RS485 direction control 1 8 DIGITAL I O PINS GPIO 32 configurable I O pins UART 3 SPI 1 I2C 1 ADC 5 CAN 1 GPIO 1 9 SOFTWARE Network Protocols ICMP ARP IP TCP UDP DHCP HTTP SNMP V1 SMTP TFTP Configuration Options Web Console Device Search Windows AP Work Mode AT Command supported MODBUS Gateway supported Upgrade Firmware Web upgrade over Ethernet Communication Protocol EZ AT Command Set Supported 1 10 ENVIRONMENTAL LIMITS Operating Temperature Standard Models 0 to 55 C 32 to 131 F Wide Temp Models 40 to 85 C 40 to 185 F Storage Temperature package included 40 to 60 C 40 to 140 F Ambient Relative Humidity 5 to 9596 non condensing 1 11 POWER REQUIREMENTS Input Voltage 3 3 VDC 45 Power Consumption 50 mA 3 3 VDC input max www bluecomm com tw Copyright 2012 Reserved by Blue Comm Electronics Co Ltd 6 BLUE BCM E100 User s Manual eH 1 12 WARRANTY Warranty Period 1 years Details See www blue comm com tw 1 13 DIMENSION Unit mm QJ e 481 1 88 2 00 2 00 gas M OY e e CU ce M
11. agi cR Pea Pan lp PRA SR DOR PPP Sala De 12 2 1 INSTALL THE E100 MODULE ONTO THE E100 EVALUATION Board 12 2 2 selecting the serial interface Nt 13 2 3 connecting tlie POWER cos eee o vou y na ex aie E USE ANE EE ENE VUE V EeEE 14 2 4 connecting to the network RN 15 2 5 connecting to a serial device pp 16 3 CHOOSING THE PROPER OPERATION MODE pp 17 3 1 tcp client mode oec con sete ert e e naoee sese era estie se sete ee gestu ep rd 17 3 2 modbus gateway mode ppp 18 3 3 udp mode SODEION T 18 3 4 tcp server mode X option pp 18 www bluecomm com tw Copyright 2012 Reserved by Blue Comm Electronics Co Ltd 1 NM BCM E100 User s Manual KUI 4 CHOOSING THE PROPER OPERATION MODE ot 19 4 1 utility Console ee ERRARE SNR S VINE SEN ERES SERERE VE UE Eu EUN FUR PERS 20 DSS 21 5 AT COMMAND SET GUIDE ires ns kr Ek Ro Ea UR ER EERR EXTA E ERRTER VENE OK RR VEN TE E RERR MERE 22 5 1 GE command set scrivere riae piu EE PIA dein TERR EE EARE PIN PER PIS SPA cda Ve 23 6 TECHNICAE SUPPORT CONTACT oiducusuA ERRARE eR UA EUR IE TA ET PE DIU P PU UR KEV ED QE 30 APPENDIX A WELL KNOW PORT NUMBERS pp 31 www bluecomm com tw Copyright 2012 Reserved by Blue Comm Electronics Co Ltd 2 BLUE BCM E100 User s Manual rn 2013 11 25 V1 0 Jacky Lee www bluecomm com tw Copyright 2012 Reserved by Blue Comm Elec
12. d Ready AT OK ve PU TROELL 192 168 127 254 2000 arial TCP_CONNECT 0 1 AT GET_TCP_STATUS 0 Connected OK AT SET_TCP_DATA 0 5 3031323334 ARET LEED 9 3031323334 TCP RERD 0 10 1122334455 RT SET TCP CONNECT 0 0 lox ARET TAP LONMECT O 1 www bluecomm com tw Copyright 2012 Reserved by Blue Comm Electronics Co Ltd 28 J TCP amp UDP TA 192 168 127 253 4098 CreateConnn WS CreateServer J8 Operate Q View V Windows Help H Language B O S Z Disconnall X DeleteConn KG F Lies Eg EF Client Modi zB Server Mod Local 192 168 127 254 2 P 192 168 127 253 4098 E100 connect to server 192 168 127 254 sucessful Send Speed B S 0 www bluecomm com tw Copyright 2012 Reserved by Blue Comm Electronics Co Ltd 192 168 127 252 4098 dbx Cle Option Br FN ded Send AtuoSend Eve fico as v Send Hex Send File Send Received 11 22 33 44 55 Send data to E100 Bee StopShow Clea Save Option Shovitex Save In Tine 1 Display data area Receive Speed B S 0 29 BLUE orm BCM E100 User s Manual 6 TECHNICAL SUPPORT CONTACT Blue comm Electronics Co LTD 12F No 8 Ln 31 Jinmen St Banciao Dist New Taipei City 22072 Taiwan R O C Tel 886 988 180 499 E Mail salesebluecomm com tw Skype Blue Comm Website www bluecomm com tw www bluecomm com tw
13. nual 5 AT COMMAND SET GUIDE The E100 supports EZ AT Command for configuring the module In order to communication each other between E100 and customer board we must use AT Commands Figure 1 1 illustrates the interface E100 Module ius l Customer Board www bluecomm com tw Copyright 2012 Reserved by Blue Comm Electronics Co Ltd 22 5 1 AT COMMAND SET BLUE BCM E100 User s Manual OMM After locating a E100 with Device Search Utility you may configure the E100 using a standard web browser Command Response Description AT OK UART communication test Illegal Command ERROR Command Response Description AT RESET OK System reset Illegal Command ERROR Command Response Description AT VER BIOS V1 0 0 0 Read version and build date BIOS 20131105163020 FW V1 0 0 0 FW B20131105163000 OK www bluecomm com tw Copyright 2012 Reserved by Blue Comm Electronics Co Ltd 23 CADRA HSU BCM E100 User s Manual Command Response Description AT DEFAULT OK System reset to default and reset right now Illegal Command ERROR Command Response Description AT ECHO 1 OK E100 echoes characters during command state ERROR AT ECHO 0 OK E100 does not echo characters during command ERROR state Command Response Description AT GET_DNS1 168 95 1 1 Read DNS 1 IP address OK A
14. opyright 2012 Reserved by Blue Comm Electronics Co Ltd 20 BCM E100 User s Manual 4 2 WEB CONSOLE After locating a E100 with Device Search Utility you may configure the E100 using a standard web browser gt C D 192 168 127 253 IBlue Comm Electronics EI Main Menu Ethernet Overview Network settings System settings Update 3 Overview 3 Network settings 3 system settings Ethernet Configurations 3 update IP configuration Static IP IP address 192 168 127 253 Subnet mask 255 255 255 0 Domain name server 1 168 95 1 1 Domain name server 2 0 0 0 0 OOB6 F 0x04 A 0x0000 Connected 192 168 127 253 Count down 298 E web CFG gt C B 192 168 127 253 pd Blue Comm Electronics 2 Main Menu Ethernet Overview Network settings System settings i Update C Overview Network settings D System settings Setti ngs 3 update f Work mode MODBUS Gateway Mode Alias Name MODBUS Gateway Communication Port Login Profile Username O0CD F 0x04 A OxOOO0 Connected 192 168 127 253 T Count down 299 www bluecomm com tw Copyright 2012 Reserved by Blue Comm Electronics Co Ltd 21 BLUE BCM E100 User s Ma
15. tronics Co Ltd BLUE BCM E100 User s Manual INTRODUCTION I 1 1 DESCRIPTION Blue Comm E100 8A Tig A EA Ra EA FB PURR aE SO aI RRE E SES nnl Ja AEE AT Command Mode MODBUS Gateway Mode Cortek M3 E100 10 100Mbps 230400 Kbps Blue Comm E100 AT Command Mode Supported MODBUS Gateway Mode Supported www bluecomm com tw Copyright 2012 Reserved by Blue Comm Electronics Co Ltd 4 BLUE BCM E100 User s Manual rm 1 2 FORM FACTOR Type Pin header module Dimensions 30 x 50 x 18 mm Weight 10 g 1 3 SYSTEM INFORMATION CPU 32 bit ARM Cortek M3 RAM 128 KB built in Flash 1 MB built in MAC built in 1 4 ETHERNET INTERFACE Number of Ports 1 Speed 10 100 Mbps auto MDI MDIX Connector RJ45 Magnetic Isolation Protection 1 5 KV built in LED Link 1 5 SERIAL INTERFACE Number of Ports 1 Transmission Format Standard TTL 6 SERIAL COMMUNICA