Home
Quick start guide
Contents
1. To stop therapy e Select Standby e To turn power off press How to lock unlock Limited access lock permits the user to select between Preset therapy settings while Full access unlock will allow the user to change all settings PHILIPS lt _ RESPIRONICS 1 2 09 39 i 7 To temporarily unlock the device e While in Standby screen press the down button below Menu and hold manual switch CD to the right for 5 seconds Note When g appears on the main screen the device is unlocked If the Access menu is not set to Full the device will switch automatically to limited access after 5 minutes of inactivity PHILIPS lt _ RESPIRONICS 0 112 05 02 PM CoughAssist T70 To select access option e Press the up button below Menu e While Option is highlighted in green press Select e While Menu Access is highlighted press Modify and then Edit to select Limited or Full access e Press OK to validate e Press Finish and Exit to return to the main screen To modify settings e The therapy settings are accessible ae ae mgo s th rough the left button below Ei ua Settings a e The scroll buttons allow selection of desired parameter e Pressing Modify will allow changing mn
2. navigate the parameter highlighted in green OK validates the choice and Finish oo returns to main screen e Three Presets are available to save a group of settings for different circumstances The settings available are displayed in the table below Preset 1225 Mode Auto Manual Cough Trak OFF ON Inhale pressure 0 to 70 cmH O in increments of 1 cmH O Only available in Auto mode Inhale flow Low Medium High Inhale time 0 to 5s in increments of 0 1s Only available in Auto mode Exhale pressure 0 to 70 cmH O in increments of 1 cmH O Exhale time 0 to 5s in increments of 0 1s Only available in Auto mode Pause time 0 to 5s in increments of 0 1s Only available in Auto mode with Cough Trak OFF Note Any change of settings made during therapy will automatically take effect at the beginning of that phase in the next cycle Modifying therapy settings Monitoring view and icons To change monitoring view e Press the up button below Menu e While Option is highlighted in green press Select and navigate down to Detailed View e Press Modify and Edit to change OFF or ON e Press OK to validate e Press Finish and Exit to return to the main screen Note When selecting detailed view OFF the following parameters are not displayed Peak Cough Flow pO HR Tidal Volume Exhale and Inhale Time setting and counter 2 Pause
3. Time setting Detailed View ON 1 Auto 03 01 2012 07 04 PM o 40 60 cmH20 Tidal Volume DOT mi 40 2 0 cmH20 Sec Inhale Settings Menu A Standby e Detailed View OFF 1 Manual 03 01 2012 07 02 PM 8 f 0 20 40 60 cmH20 PiE CR TAE a E CS S S E S 40 cmH20 Inhale Symbols and icons Color code green pause yellow exhale blue inhale SD card inserted SD card error g Memory card writing copying data to SD card Full access Remote control foot pedal connected External battery indicator red few minutes left Detachable battery indicator red few minutes left Q Q Pulse oximeter green means connected flashing With means questionable data Breath synchronization tool displayed remaining time of each phase during Auto mode No measurement is performed or questionable data Informational message information available in the Information Log Power source in use indicator box is placed around the battery being used Charging indicator detachable battery is being charged 8 30 12 4 23 PM
4. whenever Preferably therapy should be performed in the morning before meals and bedtime Feature Effective pressure cmH O Inhale time in s Exhale time in s Pause time in s In Auto mode Cough Trak triggering feature In Auto mode Mode and Preset Data management DirectView EncorePro Adults Pediatrics 35 up to 45 adjust to patient condition 2 to 3 1 to 2 2to3 2 or less Options the menu 2 to 3 As small as possible For patients who have some inspiratory drive this feature will trigger on the patient s inspiration to help synchronize the therapy with the patient s effort Therapy parameters can be titrated modified in Manual mode to evaluate the best therapy for the patient before setting up automatic settings Information Up to 3 different Presets can be saved to provide Log different therapies i e prophylactic use mucus plugs lung volume recruitment etc Data such as peak cough flow tidal volume SpO or time counters available in detailed view Clear ON can be useful for both setting therapy Patient Data parameters and assessing therapy efficiency Therapy data recorded internal memory and SD Safely Remove card peak cough flow tidal volume pressure SD Card SpO heart rate pattern of usage Write Event Log to SD Card A The settings should always be checked before beginning therapy Guidelines are intended to serve only as reference They do not supers
5. Philips Healthcare is part of Royal Philips Electronics How to reach us www philips com healthcare healthcare philips com Asia 49 7031 463 2254 Europe Middle East Africa 49 7031 463 2254 Latin America 55 11 2125 0744 North America 1 425 487 7000 800 285 5585 toll free US only Philips Respironics 1010 Murry Ridge Lane Murrysville PA 15668 Customer Service 1 724 387 4000 800 345 6443 toll free US only Respironics Inc 1001 Murry Ridge Lane Murrysville PA 15668 USA Philips Respironics International Headquarters 33 1 47 28 30 82 Philips Respironics Asia Pacific 65 6882 5282 Philips Respironics Australia 61 2 9666 4444 Philips Respironics China 86 021 24127311 Philips Respironics Deutschland 49 8152 93 06 0 Philips Respironics France 33 2 51 89 36 00 Philips Respironics Italy 39 039 203 1 Philips Respironics Sweden 46 8 120 45 900 Philips Respironics Switzerland 41 6 27 45 17 50 Philips Respironics United Kingdom 44 800 1300 845 www philips com respironics This guide contains abstracted information from the User Manual please refer to the latest for complete information regarding the CoughAssist T70 device 2012 Koninklijke Philips Electronics N V All rights are reserved PHILIPS CoughAssist T70 is registered trademark of Philips Philips Healthcare reserves the right to make changes in specifications and or to discontinue any product at any time withou
6. ches Infant Toddler Small adult Medium adult Large adult Mouthpiece Trach Toddler adaptor mask P b Small medium and large masks CoughAssist T 70 Device overview Starting therapy 7 Modifying therapy settings Monitoring view and icons Suggested guidelines for therapy PHILIPS RESPIRONICS sense and simplicity 8 30 12 4 23 PM Device overview Display screen Manual switch to activate Inhale right and exhale left phases Power on Power off Perform action specified on screen Navigate menus or change setup Standby Peak Cough Flow 222 vmin oe He Tidal Volume 514 mi WE o 20 at omH20 Sec ye Inhale Breathing circuit connection Fan exhaust Air outlet must be kept uncovered Detachable battery Filter Air inlet ac power inlet Remote control connector USB connector for service only SpO connector DC power inlet Note When the remote control foot pedal is connected the manual switch is disabled 15553_RIP_CoughAssistT 70_QStartGuide_1099095_v1 indd 7 12 To start therapy Connect the device to AC or DC power source or use the detachable battery e Press to power on the device e Select Therapy to start the treatment
7. ede established medical protocols or instructions from physician 6 Device menu To access device menu press the up button below The menu selection and their corresponding parameters are displayed in the table below LCD brightness date format time format month day year hour and minutes Only in Full access mode menu access detailed view language pressure units therapy hours SpO heart rate HR peak cough flow tidal volume serial number model number software version calibration date SD card capacity detach battery serial number detach battery cycles therapy hours Informational messages about the device will be indicated by the icon The log menu displays the list of messages that occurred i e battery not charging or replace battery and allows them to be cleared Allows clearing previous data from device memory and SD card to record new data i e for a new patient Allows removing SD card without risk of losing or damaging recorded information follow messages displayed on screen Copies event log data from the device to the SD Card follow message displayed on screen Mask fitting Landmarks a Side of mouth Bridge of nose zone c Below the lower lip To choose a well fitted mask ensure the entire mouth and nose are included inside the mask Make sure the top of the cushion is not too high on the bridge of the nose area No leak should remain Mask size in
8. t notice or obligation and will not be liable for any consequences resulting from the use of this publication 1099095 ROO JH 08 29 2012 15553_RIP_CoughAssistT70_QStartGuide_1099095_v1 indd 1 6 Suggested guidelines for therapy Standard treatment procedure Adapting to the patient For a patient using this device for the first time it is advisable to begin with lower pressures such as 10 15 cmH O positive and negative pressure and low inhale flow It will familiarize the patient with the feel of mechanical insufflation exsufflation easier pause phase 4 to 6 cough cycles compose a sequence 20 to 30 seconds of resting time is suggested between sequences allowing for secretion removal As the patient becomes more needed comfortable with the therapy progressively increase the inspiratory and expiratory pressures by 5 to 10 cmH O each sequence of 4 to 6 breaths Effective pressures may be around 35 45 cmH O Tip To help the patient understand and become comfortable with the therapy the patient synchronization dial G is provided in the center of the screen during Auto mode Cough Trak may also be enabled to help synchronize the therapy with the patient s inspiratory effort to make acclimation to the therapy General therapy description e 1 cough cycle is composed of an inspiratory expiratory and e A treatment is composed of 4 to 6 sequences and can be performed several times a day
Download Pdf Manuals
Related Search
Related Contents
素材ファイルを削除する 取扱説明書 - マックス WV-CW594E WV-CS580/G WV KIL-300S/400S/400A型 USE AND MAINTENANCE 全項一括 (PDF 4.1MB) Compaq SR1677CF Handheld TV User Manual GOCLEVER MINI Service and Maintenance Instructions Copyright © All rights reserved.
Failed to retrieve file