Home
User Manual
Contents
1. 1096 mm for full mesh versions Electrical Parameters Supported bus types Ethernet PCle SATA SAS USB 2 0 USB 3 0 System Management Bus 1 C SMB 10 100 1000Base T and 10GBase T gt 10 Gbit s PCle 1 2 3 gt 8 Gbit s Serial ATA 1 5 3 0 6 0Gbit s Rev 2 x 3 x and SATA Express 8Gbit Rev 3 2 Low Speed Full Speed High Speed mode Super Speed mode 5Gbit s 100 kbps 400kbps 1Mbps Hot swap supported Power input Power bugs power studs on request special power connection adapter boards to connect the CPCI Serial backplane with CPCI Serial power backplane without any cabling Max current carrying capacity 12V GND 5V GND STANDBY 6 65 A per slot on a 3U System 0 95 A per slot on a 3 U System Amtsgericht Mannheim HRB 503549 Gesch ftsf hrer Daniel Stirpe Henry Grimm Pentair Technical Solutions GmbH Langenalber Str 96 100 D 75334 Straubenhardt PENTAIR PENTAIR ELECTRONICS PROTECTION SCHROFF Max voltage drop between any two points on the backplane on 12 V on 5 V Standby lt 100 mVpp lt 20 mVpp Clock frequency 100 MHz on PCle Amtsgericht Mannheim HRB 503549 Gesch ftsf hrer Daniel Stirpe Henry Grimm Pentair Technical Solutions GmbH Langenalber Str 96 100 D 75334 Straubenhardt
2. backplane and power connection adapter is also available For further details please visit our webpage at www pentairprotect com 3U CompactPCI Serial backplane with power backplane on the left hand side front view Amtsgericht Mannheim HRB 503549 Gesch ftsf hrer Daniel Stirpe Henry Grimm Pentair Technical Solutions GmbH Langenalber Str 96 100 D 75334 Straubenhardt PENTAIR ELECTRONICS PROTECTION SCHROFF gt PENTAIR niet ige ra E fer E e n 3U CompactPCI Serial backplane with power backplane rear view Power adapter boards The easiest way to connect the 12 V payload power between the CompactPCl Serial backplanes and the corresponding power backplane is the use of the Schroff power adapter boards Those PCBs have voltage rails for 2 voltages inside 12 V and GND They are mounted on the power bugs of the backplane and power backplane For selecting the correct power adapter and for assembly instruction please refer to the CompactPCl Serial power backplane manual at www pentairprotect com Description term number Power adapter board 3x V1 3x V2 121212 23098 399 Power adapter board 2x V1 2x V2 1212 23098 400 Power adapter board 3x V1 3x V2 122121 23098 401 Power adapter board 2x V1 2x V2 1221 23098 402 Current carrying capacity Power adapter boards 60 Amp with 25 K temperature rise 70 Amp with 32 K temperature rise Power backplane power bug X111 X112 120 Amp CompactPCl Serial back
3. PENTAIR ELECTRONICS PROTECTION SCHROFF gt PENTAIR Users guide Revision 1 2 09 30 2015 CompactPCI Serial backplanes 23007 6xx CompactPCl Serial is a new standard that supports the fast serial protocols PCI Express Serial ATA USB and Ethernet Each Schroff CompactPCI Serial backplanes supports the current generation of protocols PCle up to Gen3 S ATA up to rev 3 0 USB 2 0 USB 3 0 and Ethernet up to 10G Base T A maximum of 9 slots is possible one system slot and up to 8 peripheral slots All 5 protocols are available simultaneously on each slot The successor to CompactPCl is based on the same mechanical form factor A robust stainless steel centering and coding pin allows use even in harsh environments The Schroff CompactPCI Serial backplane portfolio comprises of system slot left and system slot right backplanes The Schroff CompactPCl Serial backplane family consists of backplanes with Ethernet routed as single star from the system slot to all peripheral slots and backplanes with full mesh Ethernet topology In addition to the backplanes with Ethernet backplanes are available where the upper connector pair J6 RP6 is assembled for rear I O on RP6 Backplanes with Ethernet routing and up to five slots have full mesh Ethernet topology implemented which includes the signal lines for the star topology as well Higher slot count backplanes with star topology and backplanes with full mesh Ethernet implementation are availab
4. ble lugs Backplane cable connectors Utility connector Tyco 8 338069 0 BERG ae REA S a a a nua ee eva Ve Wa Sense RTN STNDBY IPMB PWR 5 V 12 V Sense PS ONH PWRBTN PWR_FAIL WAKE_IN PRSTH IC SCL IC SDA Accessories rh Semen cei cere nei eni Qu Lt ka mss ome ty ome o ems WE MN DIEN CN 6 pin 2x loop 4 pin 2x loop 5 V standby Molex 44914 0401 STNDBY IPMB PWR 5 V GND STNDBY IPMB PWR 5 V Max 8 55 Amp per contact 7 23204 879 Power cable ODD terminal 23204 880 PPC POWER 3x faston cable addo Anput Power 3x faston cable Mains power for 1 slot backplanes Molex 43045 0618 IPMB connector optional Molex 53398 0571 eo ret z not assembled by default I C SCL GND IC SDA 5 V STNDBY STNDBY 12 V IPMB PWR 5 V n C GND n c Max 8 55 Amp per contact Discrete Lo D Discrete ED eal Lo I mE Discrete 650 00 150 300 500 500 Discrete so Amtsgericht Mannheim HRB 503549 Gesch ftsf hrer Daniel Stirpe Henry Grimm Pentair Technical Solutions GmbH Langenalber Str 96 100 D 75334 Straubenhardt PENTAIR ELECTRONICS PROTECTION SCHROFF PWR BPL PWR BPL CPCI Serial backplane CPCI Serial backplane 23098 397 23098 397 23007 62x 7xx 23007 621 641 661 681 Cable connectors on the backplane rear side Power supply A pluggable Schroff CompactPCI Serial PSU with corresponding power
5. ectors J2 J5 RP2 RP5 is possible as an option Ethernet is implemented at connector J6 by 4 differential pairs to support 10 100 1000Base T and 10GBase T Ethernet is routed in a single star or full mesh topology depending on the backplane part number Since the revision 2 0 of the CompactPCI Serial specification rear I O is also possible on the connector J6 RP6 In that case Ethernet routing won t be implemented on the backplane Topology example CPCI Serial other topologies are available on www pentairprotect com 9 Slot Backplane System Slot Left FM Physical Slot Number ea nu om orto oo f owo oo ooo oo ooo Eth 7 Eth 6 Eth 5 Eth 4 Eth 3 Eth 2 PCle 8 PCle 7 PCle 6 PCle 5 PCle 4 PCle 3 PCle 2 PCle 4 USB3 0 8 USB3 0 7 USB3 0 6 USB3 0_5 USB3 0_4 USB3 0_3 USB3 0 2 USB3 0 1 USB2 0 8 USB2 0 7 USB2 0 6 USB2 0 5 USB2 0 4 USB2 0 3 USB2 0 2 USB20 1 use21 USB2 5 USB2 6 USB27 SATA 8 SATA 7 SATA 6 SATA 5 SATA 4 SATA 3 SATA 2 SATA 1 SGPIO PO SMB PClexpress Fat Pipe 8x Amtsgericht Mannheim HRB 503549 Gesch ftsf hrer Daniel Stirpe Henry Grimm Pentair Technical Solutions GmbH Langenalber Str 96 100 D 75334 Straubenhardt PENTAIR ELECTRONICS PROTECTION SCHROFF gt PENTAIR Ordering information The following tables list the part numbers of the Schroff CompactPCl Serial backplanes with some indication about availability and lead time As this is a subjec
6. le Schroff CompactPCI Serial backplanes are available with or without rear I O connectors on J2 J5 RP2 RP5 on each peripheral slot For partial rear I O connector assembly slot counts which are not in the current Schroff CompactPCl Serial backplane portfolio conformal coated backplanes or custom developments based on the Schroff standard backplane portfolio please contact Schroff sales contact or send an inquiry to backplanes pentair com Applicable Specifications PICMG CPCI S 0 Rev 2 0 Amtsgericht Mannheim HRB 503549 Gesch ftsf hrer Daniel Stirpe Henry Grimm Pentair Technical Solutions GmbH Langenalber Str 96 100 D 75334 Straubenhardt PENTAIR ELECTRONICS PROTECTION SCHROFF gt PENTAIR Assembly instructions amp general information Mounting Attach the backplane using every non plated mounting hole at the top and the bottom to fix the backplane to the system subrack with M2 5 screws Chassis GND If only the non plated mounting holes are used the backplane GND will be isolated from the chassis GND On the top and bottom mounting hole rows there are 2 mounting holes near each other one plated marked with a C and one non plated marked with an I Mounting holes for l isolated or C connected mounting of backplane GND to Chassis GND If connected mounting of the backplane is required please assemble screws in each plated mounting hole of the backplane Spring washers are recommended i
7. mber Item number Item number a mewem cxwren nene ame zsoorsen zum 2 sores cones asoro soore sorses mures nme mes O a mewem rues zen caen 0c s moves rues 23007895 mms 000000 000 e morem cxwpew 23007896 cxpewe 8 aerem cxwpems aaa ana e mewem murem aaoreser ana co o 000 Bold printed item numbers have a maximum lead time of 2 weeks small quantities please ask your Pentair Schroff sales contact for availability and lead time Amtsgericht Mannheim HRB 503549 Gesch ftsf hrer Daniel Stirpe Henry Grimm Pentair Technical Solutions GmbH Langenalber Str 96 100 D 75334 Straubenhardt gt PENTAIR Technical data PENTAIR ELECTRONICS PROTECTION SCHROFF Further requirements on request at backplanes pentair com Mechanical and climatic parameters Operating temperature Storage temperature Humidity with conformal coating Flammability PCB connectors and components Ceramic caps Mechanical durability Mating cycles Mating force Unmating force Compliant pin insertion force Durability All contacts powered at Dimensions mm Width please see drawing Height 3U 6U Thickness 55 C to 85 C 55 C to 125 C max 95 not condensing UL 94 V O Fire proof level 2 0 40N maximum contact 0 10N minimum contact 25N maximum 200 cycles 1A pin 7 62 11 70 n 1 x 20 32 mm 128 5 mm 3 8 mm 1096 mm 5 1 mm
8. nstead of flat washers If both grounds are isolated creepage and clearance between screw and digital GND are in accordance with EN60950 Power input The backplane provides power terminals with M4 thread power bugs to connect power cables for 12V and GND GND starts on each backplane below the System slot and changes every other slot the potential with 12V M4 cable lugs should be used to connect the power cables to the power bugs A maximum of 2 cable lugs are recommended per power bug Please assemble the cable lugs with the flat side to the power bug to ensure the correct isolation distance between the not insulated part of the power cable and not insulated parts of the backplane Correct orientation Not recommended Cable lug assembly Power bug option Cable lug assembly Power stud option m For harsh environments with very high shock and vibration values a power stud with nuts is recommended Schroff CompactPCI Serial backplanes are already prepared to accept a power stud instead of the power bugs assembled as standard option Please ask your Schroff sales contact for a Amtsgericht Mannheim HRB 503549 Gesch ftsf hrer Daniel Stirpe Henry Grimm Pentair Technical Solutions GmbH Langenalber Str 96 100 D 75334 Straubenhardt gt PENTAIR PENTAIR ELECTRONICS PROTECTION SCHROFF configured version with M4 power studs assembled or send an inquiry to backplanes pentair com The power stud accepts a maximum of 2 ca
9. plane power bug 30 Amp Amtsgericht Mannheim HRB 503549 Gesch ftsf hrer Daniel Stirpe Henry Grimm Pentair Technical Solutions GmbH Langenalber Str 96 100 D 75334 Straubenhardt PENTAIR ELECTRONICS PROTECTION SCHROFF gt PENTAIR Backplane front view n 1 x20 32 7 62 11 70 S a 380 LJ LI EJ N 2 J namen EX ET 636 il if l S g mL 2 80 3 00 Figure shows a 9 slot backplane The overall width at the different slot counts is 7 02 11 70 n 1 x 20 32 mm Backplane rear view Ei nm orn AA ou LrAg A i T jad bebe mm a MIT f 7 Bi ug f FA LE I J TETE TE m br rm mo VM int MEUSE LE edle ID pene renee a Das m z i ETE T r a 3 hil aiia that lal as Tre P fe E NE m ST a n uei iata a i ve TC Pa hid eid r pe khi r m i i fierent Peer tho u ee m a E ved ALE LE vj a eds 4 LE Pepe edh barat H Jue z not assembled by default Amtsgericht Mannheim HRB 503549 Gesch ftsf hrer Daniel Stirpe Henry Grimm Pentair Technical Solutions GmbH Langenalber Str 96 100 D 75334 Straubenhardt PENTAIR ELECTRONICS PROTECTION SCHROFF gt PENTAIR Backplane topology CPCI Serial backplanes with a maximum of 9 slots support the full set of serial links at all slots The serial links SATA SAS USB2 3 PCle are arranged as a single star architecture Rear I O at the CPCI Serial peripheral slots at conn
10. t which might change in time or new versions will be added over time please ask your Schroff sales representative for the current list or contact us at backplanes pentair com Some Schroff CompactPCl Serial backplanes already have a slot for a pluggable 19 power supply integrated on the backplane In the ordering information table those are marked with the slot count information x y pwr where the x stands for the number of CompactPCl Serial slots and the y for the number of slots for pluggable power supplies For the backplane power connector type and pinout please refer to the table in the CompactPCl Serial power backplane user guide and for the dimensions of the backplane to the master drawing of those backplanes Please visit the CompactPCl Serial backplane section of our webpage www pentairprotect com for these documents System slot left backplanes Ethernet star topology Ethernet full mesh topology Rear I O on RP 6 with rear I O without rear I O with rear I O without rear I O with rear I O without rear I O Slot count Item number Item number Item number Item number Item number Item number amp mores cxwpem z007 ana e mewem cene 2300788 an EE 77 RNECTONE TON 7 BERNER System slot right backplanes Ethernet star topology Ethernet full mesh topology Rear I O on RP 6 with rear I O withoutrear I O withrear I O without rear l O with rear l O without rear I O Slot count Item number Item number Item number Item nu
Download Pdf Manuals
Related Search
Related Contents
MOVIMOT® MM..D com motor CA DRS/DRE/DRP - SEW カタログはこちら Manuel d`utilisation CybeL`AGEN CE D em ande de m Nor-Mag Magnetic Flowmeters Modèles à entraînement par courroie ou par chaîne NM-SESES Tutorial - Numerical Modelling GmbH In-Sight® Micro Series I/O Module Installation Manual - Solu Hampton Bay 17208 Installation Guide QCChart2D User Manual - Quinn Copyright © All rights reserved.