1. O G www prolight o uk O OJO MOD DOWN UP CE 24 FUSE 2A 250V wo amp DMX channel mode Technical specifications 01 Bracket 02 Bracket tightening knobs 03 Earth point 04 Safety eye 05 LED display 06 Function buttons 07 DMX input socket 08 DMX output socket 09 PowerCON in socket 10 PowerCON out socket 11 Fuse 2A 240V O SAFETY EYE In the box 1 x fixture 1x 13A powerCON mains cable amp 1 x user manual Operating instructions Operating in DMX control mode gives the user the greatest flexibility wnen it comes to customising or creating a show In this mode you will be able to control each individual trait of the fixture and each fixture independently To access the DMX channel mode press the MODE button on the rear of the unit to show JLH on the LED display then use the UP and DOWN buttons to set the desired DMX address of either 3 5 7 or 8 DMX channel modes MT II To set the units address press the MODE button on the rear of the unit to show LiL I on the LED display then use the UP and DOWN buttons to set the desired address from UN 1 5 Id 3 channel mode 1 2 3 O 000 255 Master dimmer 0 100 001 005 O 06 010 011 255 Strobe slow to fast www prolight co uk 5 channel mode 000 255 Red 0 100 000 255 Green 0 100 000 255 Blue 0 100 000 255 Amber 0
2. elumen8 Alu Quad Par 64 18 x SW RGBW RGBA User Manual Order code ELUM113 Lumens Safety advice WARNING FOR YOUR OWN SAFETY PLEASE READ THIS USER MANUAL CAREFULLY BEFORE YOUR INITIAL START UP e Before your initial start up please make sure that there is no damage caused during transportation e Should there be any damage consult your dealer and do not use the equipment e To maintain the equipment in good working condition and to ensure safe operation it is necessary for the user to follow the safety instructions and warning notes written in this manual e Please note that damages caused by user modifications to this equipment are not subject to warranty TAKE CARE USING KEEP THIS EQUIPMENT THIS EQUIPMENT AWAY FROM RAIN MOISTURE AND LIQUIDS HIGH VOLTAGE RISK OF ELECTRIC SHOCK IMPORTANT The manufacturer will not accept liability for any resulting damages caused by the non observance of this manual or any unauthorised modification to the equipment e Never let the power cable come into contact with other e If the equipment is dropped or damaged disconnect the cables Handle the power cable and all mains voltage mains power supply immediately and have a qualified connections with particular caution engineer inspect the equipment before operating again e Never remove warning or informative labels from the unit e If the equipment has been exposed to drastic e Do not open the equipment a
3. 100 000 255 White 0 100 Alu Quad Par 64 User Manual 4 elumen8 7 channel mode Red 0 100 Green 0 100 Blue 0 100 o Jon gt e Master slave mode Operating instructions 8 channel mode 6 000 255 Green 0 100 8 000 255 wnite 0 100 To set the master unit press the MODE button on the rear of the master unit then select your desired program To set in slave mode press the MODE button on the rear of the unit and set the MT address to show LiL I on the LED display The unit will now run in sequence with the master unit Sound active mode To access the sound active mode press the MODE button on the rear of the unit to show on the LED display The unit will now be in sound active mode Now use the UP and DOWN buttons 599 00 low 99 high to set the sound sensitivity level from 500 Cert Note The higher the value the more sensitive it will be and is set to 41 as default Static colour mode To access the static colour mode press the MODE button to show L Li I on the rear of the unit FN Now use the UP and DOWN buttons to select one of the 30 static colours Built in programs mode To access the built in programs mode press the MODE button on the rear of the unit to show on the LED display Now use the UP and DOWN buttons to select between the 6 built in programs 5 colour change ever
4. Special note Line termination When longer runs of cable re used Termination reduces signal transmission you may need to use a terminator on problems and interference It is always the last unit to avoid erratic behaviour advisable to connect a DMX terminal resistance 120 Ohm 1 4 W between pin 2 Using a cable terminator will decrease DMX and pin 3 DMX of the last fixture the possibilities of erratic behaviour 3 pin Order ref CABL90 5 pin Order ref CABL89 5 pin XLR DMX connectors Some manufactures use 5 pin XLR connectors for data transmission in place of 3 pin 5 pin XLR fixtures may be implemented in a 3 pin XLR DMX line When inserting standard 5 pin XLR connectors in to a 3 pin line a cable adaptor must be used The diagram below details the correct cable conversion 5 pin XLR socket Pin 1 GND screen 3 pin XLR socket Pin 2 Signal an Pin 1 GND screen Pin 3 Signal Pin 2 Signal Pin 4 N C Pin 3 Signal Pin 5 N C 5 pin XLR socket 3 pin XLR socket Pin 1 GND screen Pin 1 GND screen an Pin 2 Signal Pin 2 Signal Pin 3 Signal Pin 3 Signal Pin 4 N C Pin 5 N C www prolight co uk Alu Quad Par 64 User Manual 7 Lumen8g Optional accessories amp WEEE notice Please contact your local retailer to purchase these accessories Optional eLumen8 Alu Tri Barn Door Optional LEDJ Alu Par 64 Series Order c
5. ect operation may lead to danger e g short circuit burns and electric shocks etc Do not endanger your own safety and the safety of others Incorrect installation or use can cause serious damage to people and or property www prolight co uk Alu Quad Par 64 User Manual 2 L umen 8 Product overview amp technical specifications Alu Quad Par 64 The Alu Quad features 18 x 8W quad colour LEDs 12 x RGBW 6 x RGBA since each individual LED incorporates a RGBW or RGBA chip behind a single lens shadows and unevenness within the field are things of the past Housed inside the rugged cast aluminium chassis is an advanced LED control panel giving the ability to run built in programs and perform full R BW RGBA colour mixing with or without DMX control e 2 year warranty e 18 x SW quad colour LEDs 12 x RGBW 6 x RGBA e Beam angle 25 e A00Hz refresh rate e DMX channels 3 5 7 or 8 selectable e Static colour colour change colour fade auto sound active and master slave modes e 0 100 dimming and variable strobe e 3 push button menu with LED display e 3 pin XLR in out sockets e PowerCON in out sockets e Fan cooled e Optional Barn Doors ELUMO41C 25 Lux 14400 3800 1850 960 615 Specifications Alu Quad Par 64 Power consumption 163W Power supply 100 240V 50 60Hz Dimensions 300 x 270 x 222mm Weight 4 3kg Order code ELUM113 300mm 270mm www prolight co uk Alu Quad Par 64 User Manual 3 elumen8
6. nd do not modify the unit temperature fluctuation e g after transportation do not connect power or switch it on immediately The arising condensation might damage the equipment Leave the equipment switched off until it has reached room temperature e Do not connect this equipment to a dimmer pack e Do not switch the equipment on and off in short intervals as this will reduce the system s life e Only use the equipment indoors e If your product fails to function correctly stop use e Do not expose to flammable sources liquids or gases immediately Pack the unit securely preferably in the e Always disconnect the power from the mains when original packing material and return it to your Pro Light equipment is not in use or before cleaning Only handle dealer for service the power cable by the plug Never pull out the plug by e Only use fuses of same type and rating pulling the power cable e Repairs servicing and power connection must only be e Make sure that the available voltage is between carried out by a qualified technician THIS UNIT CONTAINS 100 240V 50 60Hz NO USER SERVICEABLE PARTS e Make sure that the power cable is never crimped or e WARRANTY One year from date of purchase damaged Check the equipment and the power cable periodically OPERATING DETERMINATIONS If this equipment is operated in any other way than those described in this manual the product may suffer damage and the warranty becomes void Incorr
7. ode ELUMO41C Floor Bracket Order Code LEDJ119 Optional Cases To keep up to date on the latest accessories and product Order codes Twin CASE17 range additions please visit www prolight co uk Twin CASE16 Correct Disposal of this Product Waste Electrical amp Electronic Equipment Applicable in the European Union and other European countries Ss with separate collection systems This marking shown on the product or its literature indicates that it should not be disposed with other household wastes at the end of its working life To prevent possible harm to the environment or human health from uncontrolled waste disposal please separate this from other types of wastes and recycle it responsibly to promote the sustainable reuse of material resources Household users should contact either the retailer where they purchased this product or their local government office for details of where and how they can take this item for environmentally safe recycling Business users should contact their supplier and check the terms and conditions of the ourchase contract This product should not be mixed with other commercial wastes for disposal CE www prolight co uk Alu Quad Par 64 User Manual 8
8. onnected in a DMX line does not influence the DMX addressing For example a fixture assigned to a DMX address of 1 may be placed anywhere in a DMX line at the beginning at the end or anywhere in the middle When a fixture is assigned a DMX address of 1 the DMX controller knows to send DATA assigned to address 1 to that unit no matter where it is located in the DMX chain DATA cable DMX cable requirements for DMX operation This fixture can be controlled via DMX 512 protocol The DMX address is set on the back of the unit Your unit and your DMX controller require a standard 3 pin XLR connector for data input output see image below Further DMX cables can be purchased from all good sound and lighting suppliers or Pro Light Concepts dealers Please quote CABL10 2m CABL11 5m CABL12 10m Note DMX cable must be daisy chained and cannot be split www prolight co uk Alu Quad Par 64 User Manual 6 elumen8 DMX setup Notice Be sure to follow the diagrams below when making your own cables Do not connect the cables Shield conductor to the ground lug or allow the shield conductor to come in contact with the XLRs outer casing Grounding the shield could cause a short circuit and erratic behaviour common DMX 512 out DMX 512 in 3 pin XLR 3 pin XLR e XLR MALE SOCKET XLR FEMALE SOCKET XLR Pin Configuration 2 cold 1 ground 1 ground cold Pin 1 Ground amp Pin 2 Negative 3Hot 3Hot Pin 3 Postive
9. y 3 seconds 30 colour change every 3 seconds www prolight co uk Alu Quad Par 64 User Manual cr FL elumen8 DMX setup Setting the DMX address The DMX mode enables the use of a universal DMX controller Each fixture requires a start address from 1 511 A fixture requiring one or more channels for control begins to read the data on the channel indicated by the start address For example a fixture that occupies or uses 7 channels of DMX and was addressed to start on DMX channel 100 would read data from channels 100 1O1 102 103 104 105 and 106 Choose a start address so that the channels used do not overlap E g the next unit in the chain starts at 107 DMX 512 DMX Digital Multiplex is a universal protocol used as a form of communication between intelligent fixtures and controllers A DMX controller sends DMX data instructions form the controller to the fixture DMX data is sent as serial data that travels from fixture to fixture via the DATA IN and DATA OUT XLR terminals located on all DMX fixtures most controllers only have a data out terminal DMX linking DMX is a language allowing all makes and models of different manufactures to be linked together and operate from a single controller as long as all fixtures and the controller are DMX compliant To ensure proper DMX data transmission when using several DMX fixtures try to use the shortest cable path possible The order in which fixtures are c