Home
installation - Appliances Connection
Contents
1. FRONT OF CABINET a CABINET BOTTOM VIEW 3 wl E O lo 2 w o iz N fal o g loo iz 2 O 2 ja m z 11 3 8 30 cabinet vlg o 14 318 36 cabinet RE m 17 3 8 42 cabinet ane f 1 112 re electrical outlet 1 7 8 BACK OF CABINET 3 HOOD a Inspect for any sign of defect or damage ie scratches dents loose seams etc b Power up the unit to make sure it is working properly Remove the protective file on the hood Remove the aluminum filters to access the inside of the hood EW INSTALLATION INSTALLATION 1 UNDER CABINET INSTALLATION Make sure all preparation steps are completed a b Feed the wires coming out of the hood through the bottom of the cabinet c Lift the unit up flush against the wall and the bottom of the cabinet d Using the screws and washers provided insert into each of the keyhole openings and tightly secure the unit against the bottom of the cabinet NOTE Install more screws through the back of the unit if necessary e Use the conversion collar for 7 ducting OPTIONAL f Connect 6 or 7 ducting to the collar of the hood g Finish off by sealing the connection points with aluminum tape 2 COLD WEATHER INSTALLATION OPTIONAL a Check with your local building codes to see if a CFM reducer is an acceptable alternative to make up air b Remove the WS55CFMR CFM Reducer and inspect for any sign of defect or damage ie Cracks br
2. 2 Aluminum filters 36 and 42 model only 3 CHARCOAL FILTERS DO NOT WASH CHARCOAL FILTERS IT WILL DISSOLVE 2 Round charcoal filter sheets When to replace a charcoal filter will depend on i How often you cook ii How long you cook iii Types of food you cook Remove charcoal filters from unit and wipe the edges with soapy water Clean the charcoal filters regularly for the most efficient suction power Do not drop charcoal filters or filler CLEANING amp MAINTENANCE KKN CLEANING amp MAINTENANCE TAWA prevent the possibility of a fire and explosion do not use flammable liquids or solvents to clean the unit or any of its parts Devas to make sure all power sources are disconnected before servicing or taking unit apart for cleaning Dries thoroughly clean the unit weekly as stainless steel can rust under certain condition or by improper cleaning 1 RANGE HOOD a Use household cleaner to remove grease or dirt from the outer shell of the unit Spray on wiping cloth or spongeand wipe in the direction of the grain to avoid scratching the unit DO NOT SPRAY DIRECTLY ONTO UNIT Clean the inner working of the unit periodically to avoid grease build up Do not open control switch panel while the hood is connected to power Use stainless steel cleaner to bring back the shine to the unit 2 ALUMINUM FILTERS o ao OTW Remove aluminum filters from unit and place in warm soapy water Clean the aluminum
3. filters regularly for the most efficient suction power Do not drop aluminum filters or filler Let it soak thoroughly and then clean it with wiping cloth or sponge Aluminum filters may also be cleaned using residential dishwasher EPA TROUBLESHOOTING TROUBLESHOOTING WARNING Acren to make sure all power sources are disconnected before starting any troubleshooting Safety gloves and glasses should be worn when working on the unit Serious injury or death may occur if safety precautions are not followed WS58 Series Light Issue All not A New Transformer replacement is required turning on Light Issue One light Aa Replace old defective fixture with new fixture not turning on Light Speed buttons not 3 Complete Control switch replacement is required staying down Speed levels not Complete Control switch replacement is reguired working correctly Unit lacking smoke Make sure a reducer has not been installed intake Unit showing no power 1 Make sure the power source is working properly indication 2 All wiring is connected Unit making humming A Replace defective capacitor with new one noise PART LIST REPLACEMENT PART LIST REPLACEMENT 30 2pcs 36 3pcs 42 3pcs 14 gt SS Description Description 1 Hood body assembly 8 Bracket 2 Air chamber 9 Transformer 3 Motor 10 Capacitor 4 Fan impeller 11 Co
4. RMATION ES Aito REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK DO NOT USE THIS FAN WITH ANY SOLID STATE SPEED CONTROL DEVICE e Regardless of heat level never leave any surface materials unattended while operating an open flame e Always turn hood ON when cooking at high heat or when flamb ing food i e Crepes Suzette Cherries Jubilee Peppercorn Beef Flamb e Depending on amount of usage clean ventilating fans and filters frequently Grease should not be allowed to accumulate on fan or filter For instructions on the how to clean see maintenance page e Never leave surface units unattended at high settings Boil overs may cause smoking and greasy spillovers may ignite as result Heat oils slowly on low or medium settings e Use proper pan size Always use cookware appropriate for the size of the surface element A TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE OBSERVE THE FOLLOWING e SMOTHER FLAMES with a close fitting lid cookie sheet or metal tray then turn off the burner BE CAREFUL TO PREVENT BURNS If the flames do not go out immediately EVACUATE AND CALL 911 e NEVER PICK UP A FLAMING PAN Doing so may result in serious burns and possibly spread the fire e DO NOT USE WATER Grease fire must be extinguished before further action may be taken Using water will agitate the grease and may cause a violent steam explosion e Use a Fire Extinguisher ONLY if gt You know you
5. WINDSTeR www windsterhood com User s Manual WS 5830SS WS 5836SS WS 5842SS NOTE PLEASE INSPECT HOOD IMMEDIATELY UPON RECEIVING CLAIM OF DAMAGE AFTER 7 DAYS OF DELIVERY WILL BE DENIED This unit is designed for indoor residential use only DO NOT USE OVER A WOOD GRILL OR MOUNT IN OUTDOOR ENVIRONMENT UNDER CABINET SERIES Please read this operation manual thoroughly before using your range hood Store it in a safe location for US when you need to reference it in the future o 2 W TABLE OF CONTENTS Ki Table of Contents Safety Information ai 2 3 Content Checklist wwwmmuuusunzununu eee 4 Measurements AA 5 PVG DAT ATION wi 6 7 nstallati cee ees 8 10 Operation amp Features wwwwmmmmmzzzzamana znz mz zanana namuna zazazazaza 11 Cleaning amp Maintenance wususususununununuzuzuzu nauza 12 Troubleshooting sissisodan 13 Part Listi Replacement sicvepsccverecsiisaseereaseeenitvaveareoseeaeebtecsionts 14 Warranty Contact US 1 cccccccccccceeseseeeeeeeeeseeeeesssnereeneees 15 16 IEJ SAFETY INFORMATION SAFETY INFORMATION A TO REDUCE THE RISK OF A FIRE ELECTRICAL SHOCK AND OR INJURY OBSERVE THE FOLLOWING Unit is intended for indoor residential use only If you should have questions contact the manufacturer at the address or telephone number listed in the warranty In case the unit should need to be cleaned or repaired switch power off at ser
6. ed Windster Hoods Inc will not be held liable for removal installation fees of the malfunctioning replacement unit WARRANTY CONTACT US KA WHAT IS NOT COVERED BY MANUFACTURE WARRANTY 1 Damages resulting from any of the following Improper installation or maintenance Any repair modification alteration or adjustment not authorized by the manufacturer or an authorized service dealer Misuse and or accidents d Incorrect electric current voltage or power supply e Improper setting of any control Pressing multiple selections at the same time f Improper chemical cleaning commercial or industrial cleaning agents 2 Products purchased for use in a commercial or industrial setting such as in a hotel office restaurant or other business Damage resulting from natural disasters earthquake flood storm etc Aluminum Filters Baffle Filters Charcoal Filters and Oil Cup Filters Light Bulbs CONTACT US Windster Hoods Inc 5101 Commerce Dr Baldwin Park CA 91706 TEL 626 962 8600 FAX 626 962 8669 Toll Free 877 350 5215 E mail Support windsterhood com Windster Hoods Inc Information subject to change without notice
7. from start to finish Plan to use as few elbows or turns as possible for more efficient air flow Collar size may need to be increased if utilizing a long duct run At least 12 of vertical duct is required before any turn Do not try to install this unit by yourself SERIOUS INJURY MAY OCCUR At least two people are needed for installation Hiring a certified installer and electrician is recommended Cold weather installation will require make up air or a CFM reducer Check with your local building codes for more detail 2 LOCATION a Determine the exact location you want to install the range hood Distance between cooktop and range hood should be between 27 33 Range hood should be mounted at stated measurements to ensure performance and lifespan of electrical components Correctly measure the dimension needed to install the unit Use Fig 1a and 1bon page 5 for measurements PREPARATION Fig 1c Cabinet FRONT OF CABINET CABINET BOTTOM VIEW 2 4 E N i 7 5 4 Z N m 11 3 8 30 cabinet 5 lt q n gaen P 6 round o k 14 3 8 36 cabinet Kalat m 17 3 8 42 cabinet ae i 4 112 4 412 electrical a TE BACK OF CABINET e For cabinet with recessed bottom use 2 3 x 12 or 15 wood strips on both sides to balance the recession Use 4 1 1 4 long flat head screws to secure the wood strips to cabinet Fig 1d Fig 1d Cabinet w recessed bottom
8. have a Class ABC extinguisher and you already know how to operate it The fire is small and contained in the area where it started The fire department is being called You are able to safely control the fire with your back to an open exit Based on Kitchen Fire safety Tips published by NFPA e e ee Loca pa Kca WH CONTENT CHECKLIST CONTENT CHECKLIST 1 CONTENTS INCLUDED 1 WS58 series 30 36 or 42 hood assembly 1 User s manual 1 2 3 Aluminum filters 36 and 42 model only Black 6 to 7 conversion collar Aluminum filters 30 model only 9 29 5 1 Screw packet 2 CONTENTS NOT INCLUDED WS58CFMR CFM reducer WS58DK 30 36 or 42 ie WS5830Dk WS58CF Charcoal filter 7 Aluminum or metal piping apog 3 TOOLS REQUIRED NOT INCLUDED Safety gloves Safety glasses Electric drill w starter bit Utility knife Philips screwdriver Spirit level Measuring tape Pe pero Writing instrument pen marker pencil Aluminum tape MEASUREMENTS EJ Bottom of hood to top of cooktop Standard 8 ceiling WJ PREPARATION PREPARATION 1 BEFORE YOU START DO NOT INSTALL IF DAMAGED RETURN OR EXCHANGE WILL BE DENIED IF INSTALLED a sa mooo Be sure you have all the content of your purchase and required tools for this installation Installation may take at least 1 to 2 hours
9. ntrol switch 5 Oil funnel 12 Panel 6 Protective grills 13 LED light 7 collar 14 Aluminum filters EEJ WARRANTY CONTACT US WARRANTY CONTACT US LIMITED WARRANTY Windster Hoods Inc warrants its product against defects in material or workmanship as follows Labor For a period of one 1 year from the date of purchase if the product is determined to be defective Windster will repair or replace the product at its option at no charge After the warranty period customer must pay for all labor charges During the labor warranty period there will be no charge for any work done on the purchased model All labor repairs are limited only to the installation of electrical components Parts In addition Windster will supply at no charge new or rebuilt replacements in exchange for defective parts for a period of two 2 years After the warranty period you must pay for all parts costs During the parts warranty period there will be no charge for parts You must provide the serial number of your unitfor any replacement parts during the warranty period This warranty applies to products purchased and serviced in the United Statesonly For products purchased in Canada please contact your local retailer where you purchased the unit for service Windster Hoods Inc will attempt to repair malfunctioning units prior to shipping a replacement In the case that a unit cannot be repaired and must be replac
10. oken flips c AFTER COMPLETING Step A D of Section 1 UNDER CABINET INSTALLATION d Place the CFM reducer onto the outlet of the unit and seal the connection point with aluminum tape Be sure it is secure with no opening or gaps p Connect a 6 ducting to the collar of the CFM reducer h Finish off by sealing the connection points with aluminum tape g NOTE If using CFM reducer you must connect the reducer to unit before continuing INSTALLATION KJ 3 DUCTLESS INSTALLATION OPTIONAL a Make sure all preparation steps are completed b Lift the ductless kit up flush against the wall and the bottom of the cabinet Fig 2a c Using the screws and washers provided insert into each of the keyhole openings and tightly secure the ductless kit against the bottom of the cabinet Fig 2b d Lift the unit up flush against the wall and the bottom of the ductless kit and tightly secure the unit with the screws provided Fig 2c e Installation is complete after the unit is secured Fig 2d NOTE Install more screws through the back of the unit if necessary EIJ OPERATION amp FEATURES OPERATION amp FEATURES 1 EASY ACCESS CONTROL SWITCH from left to right 29 5 Button 1 Power ON OFF Button 2 Low Speed Button 3 Medium Speed Button 4 High Speed Button 5 Lights ON OFF 2 ALUMINUM FILTERS a b 2 14 x 11 1 2 Aluminum filters 30 model only 3 14 x 11 1
11. vice panel and lock service disconnecting means to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a prominent warning device such as a tag to the service panel Installation work and electrical wiring must be done by a qualified technician in accordance with all applicable codes and standards including fire rated construction Sufficient air is needed for proper combustion and exhausting of gases through the flue chimney of fuel burning equipment to prevent back drafting Follow the heating equipment manufacturer s guideline and safety standards such as those published by the National Fire Protection Association NFPA and the American Society of Heating Refrigeration and Air Conditioning Engineers ASHRAE and the local code authorities Because the unit is made of stainless steel it may contain sharp edges Be careful to avoid cuts and abrasions by wearing protective gloves during installation and cleaning Before you begin to cut or drill into the wall verify that there is no electrical wiring or any other hidden electrical components Ducted fans must always be vented to the outdoors The unit must be properly grounded and installed at the recommended height before beginning operation To reduce the risk of fire use only metal ductwork Acao FOR GENERAL VENTILATING USE ONLY DO NOT USE TO EXHAUST HAZARDOUS OR EXPLOSIVE MATERIALS AND VAPORS SAFETY INFO