Home
8-Channel Handheld Screw Cap Capper/Decapper
Contents
1. Cryobank Caps 10 racks of 96 caps case 1 2 1 3 e All tubes are sterile with a U bottom design Colored cap options are available with all product configurations Please contact your sales representative for details Hazards and Precautions 1 2 1 There are no known hazards associated with the Thermo Scientific 8 Channel Decapper when it is operated in accordance with the instructions in this manual 1 2 2 If the equipment is used in a manner not specified by the manufacturer the protection provided by the equipment may be impaired Environmental Operating Conditions 1 3 1 Operating Temperature 10 35 C 50 95 F 1 3 2 Relative Humidity 10 9596 non condensing 2 Parts 2 1 Included in this packaging should be the following Thermo Scientific 8 Channel Decapper Power Supply for charging battery or for operation with AC current Desktop Stand Rack of Matrix or Nunc Caps depending upon model ordered 5 Operation Manual 6 Certificate of Warranty and Warranty Registration Card Power Adapters for International Use WP N 2 2 If any of the above parts are missing please contact your Thermo Fisher Scientific representative or their authorized distributor 2 3 All critical parts of the Thermo Scientific 8 Channel Decapper are identified below _ Ca p Decap button Ejector Trigger lt Handle Battery Status Indicator E Recharge socket 1 Theme Maly Ejector Plate Y Cap
2. Drivers 3 Basic Operation 3 1 3 2 3 3 Power Requirements 3 1 1 Power supply input 100 V 240V AC 50 60 Hz 0 5 A 3 1 2 Power supply output 12 0V DC 1 0 A constant voltage 3 1 3 Explanation of symbols on power supply e for indoor use only gt e Class 2 power supply 2 e DC Symbol Decapping Technique 3 2 1 Hold the decapper loosely with a 75 angle between the forearm and upperarm to minimize potential muscle strain Charging the Decapper 3 3 1 Before first time use charge the decapper by plugging the power supply into the recharge socket at the base of the handle 3 3 2 Simply plug the other end into a standard 100 240 volt 50 60 Hz wall socket and allow the unit to charge up to 2 hours at which time the unit will be fully charged 6 3 3 3 For added ease and convenience the decapper features e Abi color LED on the front of the handle that indicates the level of battery charge o LED alternatively blinking Red amp Green Charging o Solid Green In operation or charge complete o Blinking Red Low battery e Special circuitry that makes it impossible to overcharge the battery and that allows the decapper to be charged or partially charged at any convenient time 3 8 4 For long term storage it is recommended that the decapper remain connected to the charger to ensure the instrument is ready for operation 3 4 Decapping 3 4 1 Place the decapper over row of tubes to be decapped mak
3. c om WEEERoHS WEEE Konformit t Dieses Produkt muss die EU Waste Electrical amp Electronic Equipment WEEE Richtlinie 2002 96 EC erf llen Das Produkt ist durch folgendes Symbol gekennzeichnet Thermo Fisher Scientific hat Vereinbarungen getroffen mit Verwertungs Entsorgungs anlagen in allen EU Mitgliederstaaten und dieses Produkt muss durch diese Firmen wiederverwertet oder entsorgt werden Mehr Informationen ber die Einhaltung dieser Anweisungen durch Thermo Fisher Scientific die Verwerter und Hinweise die Ihnen n tzlich sein k nnen die Thermo Scientific pum Produkte zu identifizieren die unter diese RoHS Anweisung fallen finden Sie unter www thermo com WEEERoHS Product specifications are subject to change without prior notice All trademarks are the property of Thermo Fisher Scientific Inc and its subsidiaries See the latest version at www thermo com Les sp cifications des produits peuvent tre modifi es sans pr avis Voir la derni re version sur www thermo com nderung von Produktbeschreibungen ist vorbehalten ohne vorherige Benachrichtigungt Sehen Sie die neueste Version an www thermo com Table of Contents Decapper Overview and Compatibility A ERE tucetuensiacnaanas Basic Operation nina Maintenance and Service DISPOSAl enter SETA orent tado too o mede DOIOIOAO0ON 1 Decapper Overview and Compatibility 1 1 Designed for use with 1 1 1 Thermo Scientific Matrix 2D Scr
4. Thermo Scientific 8 Channel Handheld Screw Cap Capper Decapper User Manual M Part of Thermo Fisher Scientific SCIENTIFIC WEEE Compliance This product is required to comply with the European Union s Waste Electrical amp Electronic Equipment WEEE Directive 2002 96 EC It is marked with the following symbol Thermo Fisher Scientific has contracted with one or more recycling disposal companies in each EU Member State and this product should be disposed of or recycled through them Further information on Thermo Fisher Scientific s compliance with these Directives the recyclers in your country and information on Thermo Scientific products which may assist the detection of substances subject to the Bases RoHS Directive are available at www thermo com WEEERoHS Conformit WEEE Ce produit doit tre conforme la directive europ enne 2002 96 EC des D chets d Equipements Electriques et Electroniques DEEE ll est marqu par le symbole suivant Thermo Fisher Scientific s est associ avec une ou plusieurs compagnies de recyclage dans chaque tat membre de l union europ enne et ce produit devrait amp tre collect ou recycl par celles ci Davantage d informations sur la conformit de Thermo Fisher Scientific ces directives les recycleurs dans votre pays et les informations sur les produits Thermo Scientific qui peuvent aider la d tection des substances sujettes la directive RoHS sont disponibles sur www thermo
5. ewTop tubes blue buttons and trigger 4906 Thermo Scientific Matrix ScrewCap Tray empty 5 trays case 4477 Thermo Scientific Matrix ScrewCap Tray colorless caps 5 trays of 96 caps case 3740 1 0 ml Thermo Scientific Matrix 2D ScrewTop tubes bulk 480 case 3741 1 0 ml Matrix 2D ScrewTop tubes 5 racks of 96 tubes case 3742 1 0 ml Matrix 2D ScrewTop tubes uncapped 5 racks of 96 tubes case 3743 500 yl Matrix 2D ScrewTop tubes bulk 480 case 3744 500 yl Matrix 2D ScrewTop tubes 5 racks of 96 tubes case 3745 500 yl Matrix 2D ScrewTop tubes uncapped 5 racks of 96 tubes case All tubes are sterile with a V bottom design Colored cap options are available with all product configurations Please contact your sales representative for details Thermo Scientific Nunc Cryobank 2D barcoded tubes black buttons and trigger 374082 500 ul Nunc Cryobank 2D barcoded tubes 2 racks of 96 tubes case 374086 500 ul Nunc Cryobank 2D barcoded tubes 10 racks of 96 tubes case 374084 1 0 ml Nunc Cryobank 2D barcoded Tubes 2 racks of 96 tubes case 374088 1 0 ml Nunc Cryobank 2D Barcoded Tubes 10 racks of 96 tubes case 374066 500 ul Nunc Bank It 2D Barcoded Tubes 2 racks of 96 tubes case 374074 500 ul Nunc Bank It 2D Barcoded Tubes 10 racks of 96 tubes case 374070 1 0 ml Nunc Bank It 2D Barcoded Tubes 2 racks of 96 tubes case 374078 1 0 ml Nunc Bank It 2D Barcoded Tubes 10 racks of 96 tubes case 374017 Racked
6. ing sure that the ejector plate is parallel with tops of caps TIP Line up the cap driver closest to the recharge socket with the tubes that are closest to you The other drivers and tubes will then line up 3 4 2 While lightly pushing down on caps toggle the button on the handle to make sure all of the caps have been seated properly into the cap drivers 3 4 3 Once all of the caps are seated push the gt button on handle until the tubes are decapped 3 5 3 6 Capping Recapping 3 5 1 Apply the caps from the cap tray onto the cap drivers Line up the decapper with the row of tubes to be recapped making sure the ejection plate is parallel with the tubes 3 5 2 Push the button to cap DO NOT push caps on Let the caps screw onto the tubes on their own 3 5 3 Once the caps are securely on the tubes squeeze the ejection trigger to remove the caps from the cap drivers Ejecting Caps 3 6 1 Once the tubes have been decapped line up the decapper with an empty row on the cap tray 3 6 2 Insert caps into cavities in cap tray 3 6 3 Squeeze ejection trigger 3 6 4 Lift decapper away from the tray while still holding ejection trigger down 4 Maintenance and Service 4 1 4 2 Decontamination 4 1 1 4 1 2 4 1 3 4 1 4 The entire 8 Channel Decapper can be cleaned with most common laboratory disinfectants but must not be submerged in liquid This instrument contains electrical components that ca
7. nnot be autoclaved Steps to disinfect e Wet a cloth with the desired disinfectant e Wipe down decapper making sure not to drip disinfectant into the inner cavity Suggested Disinfectants e Alcohol Wipes e 5 Bleach Solution e RNase Away e DNA Away Service Maintenance Service the decapper after 30 000 cycles 2500 racks or 1 year of continuous use whichever occurs first 5 Disposal The disposal of the decapper is the responsibility of the customer and must be done in an environmentally responsible manner 10 6 Warranty 6 1 A 12 month warranty is included with the decapper purchase 6 2 A preventive maintenance and service package is available from Thermo Fisher Scientific or appointed distributor Details are available on request Please see cover page for customer service details 11 NOTES SCIENTIFIC
Download Pdf Manuals
Related Search
Related Contents
Manual del usuario y garantía Wooden Camera 152100 CURSO BÁSICO DA LIBRAS (LÍNGUA BRASILEIRA DE SCHEDULE-III (Volume-A) TECHNICAL Frigidaire FPCP07D7MS Product Specifications Sheet Instruction Manual - Test Equipment Depot フレームマウントキット 取付方法 safety - Bock Industries, Inc. Copyright © All rights reserved.