1. 1 Key Set 20 Alarm Board 2 Front Door 21 Internal HDD Bracket 3 Transparent Sheet 22 Riser Card Optional 4 Air Filter 23 Bracket 5 LED Holder 24 Card Support Beam 6 Front Panel 25 Thermal Board 7 Cable 26 Rear Plate 8 ATX Cable 27 Top Cover 9 Front Plate 28 Motherboard Plastic Post 10 USB 29 HDD Tray 11 PS 2 30 Power Supply 12 Handles 31 Slim ODD Cover 13 Rack Mounting 32 HDD Bracket 14 Chassis 33 Slim ODD Bracket L 15 Wire Saddle 34 Slim ODD Bracket R 16 System Fans 35 Power Bracket 17 Fan Bracket 36 SAS SATA HDD Backplane 18 Guide Rail Bracket 37 Fan Bracket 19 Add on Card Guide Rail 38 HDD Fan ACP 2320MB User Manual 34 Motherboard amp Riser Card Options B 1 Motherboard Options ACP 2320MB supports a variety of Advantech ATX MicroATX motherboards as below Users can contact a local sales representative for detailed information Table B 1 ATX motherboard options Model Name Bus PCI PCle X16 PCle X8 PCle X4 PCle X1 SATA ASMB 784 3 1 X16 Gen 3 or 2 X8 2 Gen 2 ASMB 782 3 2 2 ASMB 781 3 2 1 1 8201 2 1 2 1 2 1 Gen 2 1 Gen 3 8221 1 5 3 1 Gen 2 ASMB 823l 4 3 AIMB 784 4 1 Gen 3 1 Gen2 1 Gen 2 AIMB 782 4 1 Gen 3 1 Gen2 1 Gen 2 AIMB 781 4 1 Gen 2 1 Gen2 1 Gen 2 AIMB 780 AIMB 769 5 1 1 AIMB 767 5 1 1 AIMB 766 4 1 2 AIMB 764 5 1 1 AIMB 763 5 1 1 AIMB 701 5 1 Gen 2 1 2 1 Gen 2
2. Table B 2 MicroATX motherboard options Model Name Bus PCle X16 PCle X8 PCle X4 PCle X1 SATA ASMB 584 1 2 1 AIMB 582 2 1 Gen 3 1 Gen 2 AIMB 581 2 1 Gen 2 1 Gen 2 AIMB 580 2 1 Gen 2 1 AIMB 567 2 1 Gen 2 1 X4 for G2 1 X1 for VG AIMB 562 2 1 AIMB 501 2 1 Gen 3 1 Gen 2 ACP 2320MB User Manual 36 B 2 Riser Card Options ACP 2320MB supports a variety of riser cards for Advantech ATX MicroATX mother boards as below Users can contact a local sales representative for detailed informa tion Table B 3 Riser card options Model Name Interface Compatible Motherboards ASMB RF348 21A1E PCle x16 2 ASMB 584 ASMB 784 ASMB 782 1PCle x8 ASMB 781 8201 8221 ASMB 823l ASMB RF3X8 21A1E PClext6 2PClex4 784 ASMB 781 8201 1PCle x8 ASMB 8221 8231 AIMB R430P 03A2E PCle x4 3 5 8201 8221 ASMB 8231 AIMB 782 AIMB 701 AIMB 781 AIMB 769 AIMB 764 AIMB 562 KIOSK AIMB RP3P8 12A1E PCle x16 2PClex8 8221 8231 AIMB 780 PCI 1 PCI AIMB 582 AIMB 581 AIMB 580 AIMB R4301 03A1E PCle x4 3 PCIe x1 AIMB 701 AIMB 781 AIMB 764 AIMB R431F 21A1E PCle x16 1PClex16 AIMB 784 AIMB 782 AIMB 781 PCle x4 2 PCle x1 AIMB 764 AIMB R43PF 21A1E PCle x16 1 PCle x16 AIMB 784 782 AIMB 781 PCI 2 PCI AIMB 764 AIMB 763 AIMB RP30P 03A1E PCI 3 PCI AIMB 780 AI
3. ACP 2320MB 2U high Rackmount Chassis with Dual SAS SATA HDD Trays AD ANTECH Enabling an Intelligent Planet Copyright This document is copyrighted by Advantech Co Ltd 2008 All rights are reserved Advantech Co Ltd reserves the right to make improvements to the products described in this manual at any time without notice No part of this manual may be reproduced copied translated or transmitted in any form or by any means without the prior written permission of Advantech Co Ltd Information provided in this manual is intended to be accurate and reliable However Advantech Co Ltd assumes no responsibility for its use or for any infringements of the rights of third parties which may result from its use Acknowledgements The ACP 2010 ASMB 584 ASMB 784 ASMB 781 ASMB 782 8201 ASMB 8221 ASMB 8231 AIMB 501 AIMB 562 AIMB 567 AIMB 580 AIMB 581 AIMB 582 AIMB 701 AIMB 763 AIMB 764 AIMB 766 AIMB 767 AIMB 769 AIMB 780 AIMB 781 are trademarks of Advantech Co Ltd All other product names or trade marks are the properties of their respective owners On line Technical Support For technical support and service please visit our support website at http www advantech com support Part No 2002232002 Edition 3 Printed in China July 2015 ACP 2320MB User Manual ii Safety Instructions 10 11 12 13 14 15 Read these safety instructions carefully
4. 1 5 Dimension Diagram OG 9 ey 29 lle e 0098890099939998000000 C 23J 5 2 lt gt lt gt c C 3 J noain H 8o 87 2 3 43 42 1 1 66 FI se 4 8 N O as 9 Y B N eS S 71 J 8 8 49 3 ES amp gt e 2 55 o E S li Y al JE zt s9 oe THY NS 2 1 2 fo D D D CEN os me s UH LO Figure 1 1 Dimension
5. Figure 2 4 Installing a motherboard Installing a Riser Card and Add on Cards The ACP 2320MB supports up to 3 add on cards via the riser card To install the riser card and add on cards please proceed as follows 1 Fasten the riser card to the riser card holder with the four screws Then insert this unit to the slot on the motherboard see Figure 2 5 2 Remove the corresponding I O bracket attached to the rear plate of the chassis Insert an add on card vertically into the proper slot on the riser card For full length cards please make sure that the card bracket has been inserted properly and the other edge of the card has been inserted into the plastic guiding fillister Then fasten the screws on the top of the I O bracket see Figure 2 6 3 Repeat Step 2 if there is more than one add on cards to be installed 9 ACP 2320MB User Manual 4 Return the riser card holder and fasten it onto the chassis Figure 2 6 Installing an add on card Note The riser card of the motherboard is specially designed to support Advantech AIMB 7XX and AIMB 5XX series There might be compatibil ity issue with other vendor s motherboards ACP 2320MB User Manual 10 2 4 2 4 1 If users purchase the ACP 2320MB with the low profile rear I O bracket then simply install the low profile add on card to the selected PCI PCle slot on the motherboard and fasten the card securely Installing the Disk Drives The ACP 2320MB comes with
6. 1 B 2 B 3 Exploded Diagram and Parts List 33 Exploded Diagraim erect E eee nice 34 Figure A 1 ACP 2320MB exploded diagram 34 Table A 1 Parts list idc inen eee tens 34 Motherboard amp Riser Card Options 35 Motherboard 0 878 36 Table 1 ATX motherboard 36 Table 2 MicroATX motherboard options 36 Riser Card Opuions ELS 37 Table B 3 Riser card 37 Cooler OptlOH rds 37 Table B 4 Cooler options 37 ix ACP 2320MB User Manual ACP 2320MB User Manual General Information This chapter provides general information about the ACP 2320MB Sections include E Introduction Specifications Power supply options E Environment specifications E Dimension diagram 1 1 Introduction The ACP 2320MB is a compact rugged 2U high rackmount industrial computer chassis designed for space conscious applications With only 2U height ACP 2320MB can accept Advantech ATX MicroATX motherboard with up to three full length add on cards with the optional riser card or with up to 7 low profile add on cards by using the optional special rear I O bracket Dual mobile SAS SATA HDD trays ACP 2320MB comes with two mobile S
7. Keep this user manual for later reference Disconnect this equipment from AC outlet before cleaning Do not use liquid or spray detergents for cleaning For pluggable equipment the power outlet shall be installed near the equipment and shall be easily accessible Keep this equipment away from humidity Put this equipment on a reliable surface during installation Dropping it or letting it fall could cause damage Do not leave this equipment in an environment unconditioned where the storage temperature under 0 C 32 F or above 40 C 104 F it may damage the equipment The openings on the enclosure are for air convection hence protect the equip ment from overheating DO NOT COVER THE OPENINGS Make sure the voltage of the power source is correct before connecting the equipment to the power outlet Place the power cord in a way that people can not step on it Do not place any thing over the power cord The voltage and current rating of the cord should be greater than the voltage and current rating marked on the product All cautions and warnings on the equipment should be noted If the equipment is not used for a long time disconnect it from the power source to avoid being damaged by transient over voltage Never pour any liquid into ventilation openings This could cause fire or electri cal shock Never open the equipment For safety reasons the equipment should be opened only by qualified service personnel If any of the
8. cooling fan and the alarm is also acti vated To stop the alarm beep press the Alarm Reset button and then replace the failed fan with a working one immediately If the TEMP LED is Red it means that inside of the chassis is overheated more than 50 C An audible alarm will be activated To stop the alarm beep press the Alarm Reset button Inspect the fan filter and the rear section of the chassis immediately Make sure the airflow inside the chassis is smooth and not blocked by dust or other particles LED indicators for SAS SATA HDD power amp status Each SAS SATA HDD tray has a pair of LED indicators for displaying the SAS SATA HDD power and the activity status Please refer to Table 3 2 for the LED defini tion summary Table 3 2 SAS SATA LED indicator functions LED Description Green Blue ole c HDD Power HDD power on N A AUS Data access Blinking HDD Status N A Idle Light SAS HDD No light SATA HDD When the system power is on and the SAS SATA HDD is well connected the HDD power LED glows steady Green If it fails to light up check connect the SAS SATA connection Or please ask a technician to inspect the related cables in the chassis When the SAS SATA HDD is transmitting some data the HDD LED blinks blue Depending on the type of HDD the HDD LED indications are different When an SAS 17 ACP 2320MB User Manual 3 2 HDD is idle the HDD LED glows steady blue When an SATA HD
9. following situations arises get the equipment checked by service personnel The power cord or plug is damaged Liquid has penetrated into the equipment The equipment has been exposed to moisture The equipment does not work well or you cannot get it to work according to the installation reference guide The equipment has been dropped and damaged The equipment has obvious signs of breakage 16 CAUTION The computer is provided with a battery powered real time clock cir 17 18 cuit There is a danger of explosion if battery is incorrectly replaced Replace only with same or equivalent type recommended by the manufacturer Discard used batteries according to the manufacturer s instructions THE COMPUTER IS PROVIDED WITH CD DRIVES COMPLY WITH APPRO PRIATE SAFETY STANDARDS INCLUDING IEC 60825 CLASS LASER PRODUCT KLASS LASER PRODUKT This device complies with Part 15 of the FCC rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and iii ACP 2320MB User Manual 2 this device must accept any interference received including interference that may cause undesired operation 19 CAUTION Always completely disconnect the power cord from your chassis whenever you work with the hardware Do not make connections while the power is on Sensitive electronic components can be damaged by sudden power surges 20 CAUTION Always ground yourself to remove
10. mally a lot more detailed than the ones we can give over the phone Please consult this manual first If you still cannot find the answer gather all the infor mation or questions that apply to your problem and with the product close at hand call your dealer Our dealers are well trained and ready to give you the support you need to get the most from your Advantech products In fact most problems reported are minor and can be easily solved over the phone In addition free technical support is available from Advantech engineers every busi ness day We are always ready to give advice about application requirements or spe cific information on the installation and operation of any of our products ACP 2320MB User Manual iv Product Warranty Advantech warrants to you the original purchaser that each of its products will be free from defects in materials and workmanship for two years from the date of pur chase This warranty does not apply to any products which have been repaired or altered by persons other than repair personnel authorized by Advantech or which have been subject to misuse abuse accident or improper installation Advantech assumes no liability under the terms of this warranty as a consequence of such events If an Advantech product is defective it will be repaired or replaced at no charge dur ing the warranty period For out of warranty repairs you will be billed according to the cost of replacement materials servic
11. two easy to maintain SAS SATA HDD trays it also accepts one slim type optical disk drive it can also accommodate two internal 3 5 HDDs Please refer to the following instructions to install the various disk drives Installing a SAS SATA HDD in the Mobile HDD tray ACP 2320MB accepts both SAS and SATA HDD Users do not need to remove chas sis cover when installing a SAS SATA HDD into the mobile HDD trays 1 Open the front door 2 want to install a SAS SATA HDD into the lower mobile tray it is neces sary to remove the front door first The small door is attached to the ACP 2320MB with the hinges without screws 3 Left shift the key latch of one HDD tray to unlock the tray Hold the handle of the tray and draw it out from the chassis 4 Slide one SAS SATA disk drive into the proper location in the tray and fix it with 4 6 screws 5 Return and push the HDD tray to the chassis until the handle of tray is moving back Right shift the key latch of the HDD tray to lock the tray 6 Repeat Steps 3 to 5 if there is the 2nd SAS SATA HDD to be installed Figure 2 7 Removing the front door and the mobile SAS SATA HDD trays 11 ACP 2320MB User Manual Figure 2 8 Installing SAS SATA HDD 2 4 2 Installing the internal HDD The ACP 2320MB provides a shockproof housing to hold two 3 5 internal HDDs To install the internal HDD please follow these steps for installation 1 To install the 3
12. use system shutdown or press this switch for a few seconds to turn off the system ATX power System Reset button Press this switch to reboot the system Alarm Reset button Whenever a fault occurs in the system e g fan failure or the chassis is overheated the audible alarm will be activated Press this button will stop the alarm from beeping Dual USB port For connecting a wide range of USB devices for data transfer backup or input PS 2 connector For connecting a keyboard or mouse depending on the mother board design ACP 2320MB User Manual 16 3 1 2 LED indicators for system status Four LEDs are placed on the left side of the front panel to indicate system health and activity Refer to Table 3 1 for the LED definition summary Table 3 1 LED indicator functions LED Description Green Orange Red ole P System power Normal N A Abnormal Hard disk drive activity N A Dataaccess N A Temperature in the Normal N A Abnormal chassis Cooling fan status Normal N A Abnormal amp D CD When the system power is on the POWER LED is always Green When the POWER LED is Red it indicates a redundant power supply failure To stop the alarm beep press the Alarm Reset button Examine the redundant power supply module right away and replace the failed module with a working one When the HDD LED is blinking Orange it means the HDD is transmitting data When the FAN LED is Red it indicates a failed
13. 2 1 Removing the top 6 Installing a emm 7 Figure 2 2 Yellow label indicating plastic post locations 7 Figure 2 3 Fastening the plastic 8 Figure 2 4 Installing a 9 Installing a Riser Card and Add on 9 Figure 2 5 Installing a riser 10 Figure 2 6 Installing an add on card 10 Installing the Disk Drives tette died bcne 11 2 4 1 Installing SAS SATA HDD the Mobile HDD tray 11 Figure 2 7 Removing the front door and the mobile SAS SATA HDD trays o ERR xd 11 Figure 2 8 Installing a SAS SATA 12 2 4 2 Installing the internal HDD seem 12 Figure 2 9 Installing the internal 13 2 4 3 Installing a slim type optical disk 13 Figure 2 10Small convert for slim type optical disk drive 13 Figure 2 11Installing slim type optical disk drive 14 Attaching the Ears and Handles sse 14 Figur
14. 5 internal HDD simply release the four screws on top of the disk drive bracket see Figure 2 9 2 Insert the disk drive into the proper location in the bracket and secure them with the screws provided 3 Return the disk drive bracket in the original position and fasten it with the screws 4 Connect the suitable cable from the motherboard to the 3 5 internal HDD Then plug the power connector into each disk drive ACP 2320MB User Manual 12 Figure 2 9 Installing the internal HDD 2 4 3 Installing a slim type optical disk drive 1 2 3 Undo the two screws on the top of the SAS SATA HDD housing and take out the brackets Remove the front cover for the slim type optical disk drive Find a small PCB converter See Figure 2 10 and connect it to the slim type optical disk drive Then fix it onto the optical disk drive by tightening the two screws provided See Figure 2 11 Fix the optical disk drive onto the brackets with the four screws provided Return the brackets with the slim type optical disk drive in the original position and fasten it with the screws Connect the 40 pin IDE flat cable from the motherboard to the optical disk drive Also plug the 4 pin power connector Figure 2 10 Small convert for slim type optical disk drive 13 ACP 2320MB User Manual Figure 2 11 Installing a slim type optical disk drive 2 5 Attaching the Ears and Handles There is a pair of ears and handles in the accesso
15. AS SATA HDD trays which provide the most economic solution for data mirroring Other data storage options include one slim type optical disk drive and two internal 3 5 HDDs with shock resistant protection And the front dual USB and PS 2 interfaces can be connected with various peripheral devices for data input backup and transferring Unique alarm detection and notification to reduce system down time ACP 2320MB has an unique alarm module This module automatically detects the system operating conditions such as power HDD fan and system temperature Once any failure happens the module gives an audible alarm to notify users to take necessary actions It also shows the system status on the front LED indicators 1 2 Specifications Construction Heavy duty steel B Disk Drive Capacity dual mobile SAS SATA HDD trays slim type optical disk drive and two internal 3 5 HDDs B LED Indicators on Front Panel Bi color LEDs green red for Power Temper ature and Fan status single color LED orange for HDD activity For the SAS SATA storage each mobile tray has a single color LED green that displays SAS SATA HDD power and a single color LED blue that displays SAS SATA HDD status B Front I O Interfaces dual USB ports and one PS 2 connector B Rear I O Interfaces Reserved two 9 D SUB openings B Security Protection The storage system power switch system reset button and alarm reset button are all behi
16. B User Manual 3 5 Replacing the Power Supply The ACP 2320MB supports a single 2U high power supply To replace the power supply proceed as follows 1 2 3 Unplug the power cord from the power supply Remove the top cover Unplug the 20 pin or 24 pin ATX power connector and 4 pin 12 V power con nector from the motherboard as well as the power connectors from the disk drives and peripherals Loosen the three screws on the rear plate and the two screws on the power sup ply bracket and then gently take it out see Figure 3 9 Replace the power supply with a new one and fasten it onto the chassis Plug the 20 pin or 24 pin ATX power connector and 4 pin 12V power connec tor to the motherboard And plug other power connectors to the disk drives and peripherals Return the top cover Then plug in the power cord Figure 3 9 Replacing the power supply ACP 2320MB User Manual 22 Dual Slot SAS SATA Backplane This chapter introduces the SAS SATA HDD backplane information Sections include E Backplane layout Connectors amp pin definition 4 1 Backplane Layout CONe LED4 mim Eg LEDe CON1 cs esseen LEN LI LEDI Figure 4 1 Front side layout connect to the HDD CN14 t SATA feno CN46 Figure 4 2 R
17. D is idle the HDD LED is off The Rear Panel The rear plate includes 3 slot I O brackets and two reserved 9 pin D SUB openings and a motherboard I O opening see Figure 3 3 Gy ec x fe cout 000008609866 Figure 3 3 Rear panel with standard I O brackets There is an optional rear I O bracket for installing low profile add on cards see Fig ure 3 4 m NI D0000000000000000 00000000 Figure 3 4 Rear panel with low profile I O brackets There is a ground screw with a washer located on the lower right of the rear panel when properly grounded this protects the system in case of electric leakage ACP 2320MB User Manual 18 3 3 3 3 1 Replacing the Cooling Fans There are two easily maintained system cooling fans behind the front plate of the chassis and one fan behind the SAS SATA HDD backplane Replacing the system cooling fan Remove the top cover Unplug both fans power connectors Loose the two screws on the fan bracket and gently pull it out see Figure 3 5 Remove the four screws on the failed fan unit and take out the fan Fasten a new fan onto the fan bracket Return the fan bracket to the chassis and fasten it with two screws Plug in both fans power connectors Re
18. DAT Table 5 9 IPMB1 Pin 1 NC Pin 3 S_SDAT_R Pin 2 S_SCLK_R Pin 4 GND Table 5 10 PSBUS1 Pin 1 V_PMBUS Pin 4 I2C_SDAT Pin 2 GND Pin 5 2 5 3 Table 5 11 SMB_3V_1 Pin 1 V_SMB Pin 3 M SDAT R Pin 2 M SCLK R Pin 4 GND Table 5 12 SMB_3V_2 Pin 1 V_SMB Pin 3 M SDAT R Pin 2 M_SCLK_R Pin 4 GND ACP 2320MB User Manual 30 Table 5 13 LEDBOARD1 Pin 1 GND Pin 9 T G LED Pin 2 V5 Pin 10 T F LED Pin 3 V12 R Pin 11 F G LED Pin 4 V5_R Pin 12 F F_LED Pin 5 V12 R Pin 13 NC Pin 6 HDD LED Pin 14 V3 3_R Pin 7 P G LED Pin 15 V5_SB_R Pin 8 P F_LED Table 5 14 VOLT1 Pin 1 V5_SB Pin 5 5 Pin 2 GND Pin 6 V3 3 Pin 3 GND Pin 7 V12 Pin 4 V5 Pin 8 V12 Table 5 15 TR1 4 Pin 1 TEMP_SEN1 4 Pin 2 GND Table 5 16 RDUPG1 Pin 1 GND Pin 2 PWR_FAIL_IN Table 5 17 BZ1 Pin 1 V5 DUAL Pin 2 EXT BUZZ Table 5 18 HDD1 Pin 1 NC Pin 2 HDD_LED_ACT Table 5 19 ALMRST1 Pin 1 GND Pin 2 ALARM_RST_IN Table 5 20 FAN1 7 Pin 1 GND Pin 3 FAN_DEC1 7_R Pin 2 V12_FAN Table 5 21 DEBUG2 Pin 1 EC SCLKO Pin 2 EC SDATO 31 ACP 2320MB User Manual Table 5 22 PWR1 Pin 1 12 Pin 4 GND Pin 2 GND Pin 5 5 ACP 2320MB User Manual 32 Exploded Diagram Parts List 1 Exploded Diagram 5 My 7 Figure A 1 ACP 2320MB exploded diagram Table A 1 Parts list
19. MB 767 AIMB 766 AIMB 582 AIMB 581 AIMB 580 AIMB 567 AIMB 501 AIMB RP3PF 21A1E PCle x16 1 PCle x 16 AIMB 780 AIMB 767 AIMB 766 PCI 2 PCI AIMB 582 AIMB 581 AIMB 580 AIMB 567 AIMB 562 AIMB 562 AIMB 501 AIMB RP10P 01A1E PCI 1 PCI AIMB 501 B 3 Cooler Option Cooler model is decided by CPU socket Users can contact a local sales representative for detailed information Table 4 Cooler options Cooler Parts number Compatible Motherboards 1960047831N001 ASMB 584 AIMB 784 ASMB 782 ASMB 781 AIMB 784 AIMB 782 AIMB 781 AIMB 701 AIMB 780 AIMB 582 AIMB 581 AIMB 580 AIMB 501 1960055362N011 5 8201 8231 1960063011N001 ASMB 8221 1960022033T000 AIMB 769 AIMB 767 AIMB 766 AIMB 764 AIMB 763 AIMB 567 AIMB 562 37 ACP 2320MB User Manual AD ANTECH Enabling an Intelligent Planet www advantech com Please verify specifications before quoting This guide is intended for reference purposes only All product specifications are subject to change without notice No part of this publication may be reproduced in any form or by any means electronic photocopying recording or otherwise without prior written permis sion of the publisher All brand and product names are trademarks or registered trademarks of their respective companies Advantech Co Ltd 2015
20. any static charge before touching the motherboard backplane or add on cards Modern electronic devices are very sensitive to static electric charges As a safety precaution use a grounding wrist strap at all times Place all electronic components on a static dissipative surface or in a static shielded bag when they are not in the chassis 21 CAUTION Any unverified component could cause unexpected damage To ensure the correct installation please always use the components ex screws provided with the accessory box A Message to the Customer Advantech Customer Services Each and every Advantech product is built to the most exacting specifications to ensure reliable performance in the harsh and demanding conditions typical of indus trial environments Whether your new Advantech equipment is destined for the labo ratory or the factory floor you can be assured that your product will provide the reliability and ease of operation for which the name Advantech has come to be known Your satisfaction is our primary concern Here is a guide to Advantech s cus tomer services To ensure you get the full benefit of our services please follow the instructions below carefully Technical Support We want you to get the best performance possible from your products If you run into technical difficulties we are here to help For the most frequently asked questions you can easily find answers in your product documentation These answers are nor
21. diagram ACP 2320MB User Manual 4 System Setup This chapter introduces the instal lation process Sections include E Installing a motherboard E Installing riser and add on cards E Installing disk drives Attaching the ears handles The following procedures instruct users to install a motherboard a riser card add on cards and disk drives into the chassis Please also refer to the Appendix A Exploded Diagram and Parts List for the detailed parts of the chassis Note Use caution when installing or operating the components with the chas sis open Be sure to turn off the power unplug the power cord and EN ground yourself by touching the metal chassis before you handle any components inside the machine 2 1 Removing the Top Cover To remove the cover please proceed as below 1 Loosen five screws on the rear and both sides of the top cover 2 Slide the top cover backwards and then lift it up see Figure 2 1 Figure 2 1 Removing the top cover ACP 2320MB User Manual 6 2 2 Installing a Motherboard The ACP 2320MB can support ATX MicroATX motherboard with up to 3 add on cards via the expanded riser card or 7 low profile add on cards via the optional spe cial rear I O bracket To install a motherboard please proceed as follows Note Use caution when installing a motherboard It s highly recommended to 2 choose a CPU cooler which is lower than 67 mm to avoid any compo E nent
22. e 2 12Attaching the ears and handles 14 PER etn td dehet Le eh Ee ennt gunt dus 16 Figure 3 1 Front panel with door closed 16 Figure 3 2 Front panel with door 16 3 1 1 Switch buttons and I O interfaces 72 1 16 3 1 2 LED indicators for system status 17 Table 3 1 LED indicator 2 2 17 3 1 3 LED indicators for SAS SATA HDD power amp status 17 Table 3 2 SAS SATA HDD LED indicator functions 17 Rear Panel et t ee he Rd MR 18 Figure 3 3 Rear panel with standard I O brackets 18 Figure 3 4 Rear panel with low profile I O brackets 18 Replacing the Cooling 19 3 3 1 Replacing the system cooling 19 Figure 3 5 Replacing the system 19 3 3 2 Replacing the fan behind the SAS SATA HDD backplane 20 Figure 3 6 Replacing the fan behind the SAS SATA HDD back dra rg n 20 vii ACP 2320MB User Manual 3 4 3 5 Chapter 4 4 1 4 2 Chapter 5 5 1 5 2 5 3 5 4 5 5 ACP 2320MB User Manual Figure 3 7 Remove the fan from the pla
23. e time and freight Please consult your dealer for more details If you think you have a defective product follow these steps 1 Collect all the information about the problem encountered for example type of PC CPU speed Advantech products used other hardware and software used etc Note anything abnormal and list any on screen messages you get when the problem occurs 2 Call your dealer and describe the problem Please have your manual product and any helpful information readily available 3 If your product is diagnosed as defective obtain RMA return material autho rization number from your dealer This allows us to process your return more quickly 4 Carefully pack the defective product a fully completed Repair and Replacement Order Card and a photocopy proof of purchase date such as your sales receipt in a shippable container A product returned without proof of the purchase date is not eligible for warranty service 5 Write the RMA number visibly on the outside of the package and ship it prepaid to your dealer Initial Inspection When you open the carton please make sure that the following materials have been shipped Chassis W UserManual m Warranty Card B Accessory box with a package of screws for fastening the motherboard optical disk drive other disk drives ears and handles etc a pair of keys a plastic post and a pair of ears and handles If any of these items are missing or damaged con
24. ear side layout connect to the RAID card or motherboard 4 2 Connectors amp Pin Definition Table 4 1 SAS SATA HDD connectors LEDs front side CON1 CON2 SAS SATA HDD connectors LED3 LED4 SATA HDD1 HDD2 power LED green LED1 LED2 SATA HDD1 HDD2 Bi Color LED blue HDD Activity blue Table 4 2 SATA cable connectors on rear side SATA1 SATA2 e RE for connecting to SAS SATA RAID card or moth Table 4 3 CN46 Power connector Pin1 12V Pin3 GND Pin2 GND Pin4 VCC Table 4 4 CN14 Fan connector Pin1 GND Pin3 5 Pin2 12 V ACP 2320MB User Manual 24 Intelligent System Module SAB 2000 This chapter introduces the alarm board and thermal sensor specifi cations Sections include E Getting Started E Specifications Connectors and Switch Setting SAB 2000 Board Layout SAB 2000 Pin Define 5 1 Getting Started Configuring the SAB 2000 SAB 2000 is pre installed inside your system chassis Hardware switch will be fine tuned according to your system layout Please refer to your user manual for its location With different system layout We can configure SAB 2000 by H W switch Please refer to Switch Setting section for detailed information For remote management function You will need to install SUSIAccess Then you will be able to monitor system fan speed system temperature CPU temperature and voltage You can also set your own alarm standa
25. interference between a motherboard and the chassis and to ensure the best air flow inside the chassis 1 Remove the card holder by loosening the two screws 2 yellow label is located inside of the chassis bottom see Figure 2 2 It shows the plastic post location for attaching the specific ATX MicroATX motherboard Users can find the plastic post in the accessory box see Figure 2 3 Insert the plastic post into the correct location and then rotate counterclockwise to fasten it onto the chassis Mark Model ATX motherboard MicroATX motherboard Special AIMB 744 AIMB 750 AIMB 760 The plastic post is in the accesory box Be sure to attach the post onto the correct location Figure 2 2 Yellow label indicating plastic post locations 7 ACP 2320MB User Manual Figure 2 3 Fastening the plastic post 3 Attach the motherboard I O shielding onto the rear plate first Then fasten the motherboard onto the chassis see Figure 2 4 4 Connect the 20 pin or 24 pin ATX power connector and the 4 pin 12 V power connector from the power supply to the motherboard 5 Return the card holder to its original position and fasten it in case you don t need to install the riser card and add on card ACP 2320MB User Manual 8 2 3 6 Connect the 9 pin USB wire PS 2 wire HDD LED wires Power switch wire and the System Reset switch wire from the chassis to the motherboard
26. nd the lockable door B Cooling System dual 8 cm x 8 cm 47 CFM hot swappable cooling fans amp one 6 cm 28 CFM fan behind the SAS SATA HDD backplane W Filters Two easily maintained filters near the front of the system fans and behind the front door E Weight 11 7 kg 25 7 lbs Dimensions W x H x D 482 x 88 x 480 mm 19 x 3 46 x 18 9 ACP 2320MB User Manual 2 Power Supply Options The ACP 2320MB can accommodate the 2U high power supply Please see the options as below Table 1 1 Power supply options Model Name PS8 250FATX XE PS8 350FATX XE 96PSR A250W2U Watt 250W 350W 250W 1 1 Redundant Input rating 115 230 Vac 100 240 Vac 100 240 Vac 3 3 9 16 3 3 15 4 45 V 9 16A 45V 9 25A 12 V1 Q 18A 12 V 16A Output voltage 12V Q 18A 412 V2 Q 18A 12 V 05 2 an 12V 0 3A 5V 0 5A 5 Vsb 3A 5 Vsb 2 A MTBF 100 000 hours 25 C 100 000 hours 25 C 100 000 hours 25 C CB CCC CE FCC CB CCC CE FCC CB CE CCC FCC Safety TUV UL EMC TUV UL EMC UL TUV Environment Specifications Table 1 2 Environment specifications Environment Operating Non operating Temperature 0 to 40 C 32 to 104 F 20 to 60 C 4 to 140 F Humidity 10 to 85 40 C 10 to 95 40 C non condensing non condensing Vibration 1 Grms 2G Shock 10 G with 11 ms duration half sine 30G wave Safety CE compliant 3 ACP 2320MB User Manual
27. place the top cover and fasten it GoNouahaAN gt 2 Figure 3 5 Replacing the system fan 19 ACP 2320MB User Manual 3 3 2 Replacing the fan behind the SAS SATA HDD backplane 1 akon D Remove the top cover Unplug the fan power connector Push the hook on the left side of the fan to take out the fan see Figure 3 7 Replace the broken fan with a new one Stick the fan to the hook on the right side of the bracket then directly push the fan into the bracket Plug in the fan power connector Replace the top cover and fasten it 6 gt V J N A N v Figure 3 7 Remove the fan from the plastic bracket ACP 2320MB User Manual 20 3 4 Cleaning the Filters The filters function to block dust or particles from the work environment and to extend the longevity of the system Periodic filter cleaning is recommended There are two filters in the chassis one is in front of the system fans and the other is behind the front door To clean the filters proceed as follows 1 2 9 4 Open the front door To remove the door filter simply push the hook and pull it out To pull out the fan filter push the hook and slide it to the right see Figure 3 8 Clean the filter with a soft brush or wash the dust away from the filter with flow ing water and let it dry thoroughly Replace the filters inside the unit Figure 3 8 Cleaning the filters 21 ACP 2320M
28. rd under SUSIAccess according to your demand For detailed information Please refer to user guide of SUSIAccess 5 2 Specifications 5 2 1 Hardware Specifications 1 ten pin hardware switch to configure alarm settings 1 SM bus interface for system and main board healthy status monitoring Up to 4 external temperature sensors 7 fan tachometer inputs 1 external IPMI module connector 1 built in buzzer for system health status notice Automatic smart fan control Reserved PCB layout for gravity and humidity sensor 5 2 2 Dimensions W Kernel module 9692S20000E 115 mm x 55 mm 5 2 3 Sensor Input Specifications W Voltage Inputs 5 VDC 5 VDC 5 VSB 3 3 VDC 12 VDC 12 VDC WB Temperature Sensors LM75 digital temperature sensor I2C interface 30 125 C 22 257 F BW Fan Speed Monitor Up to 7 fans 0 20000 RPM Power Monitoring Detect Redundant power Get IPMI amp SUSI Command 5 2 4 System Status Monitoring amp Management W Real time healthy status monitoring Realtime system main board FAN speed temperature monitor W Remote system monitor through SUSIAccess W Alarm through on board buzzer and LED signal 5 2 5 Management Functions WB Web based remote configure control and monitor WB Remote reset power down and power up Remote digital output signal control ACP 2320MB User Manual 26 5 2 6 Alarm Notification Table 5 1 LED amp Beep Item Status Cri
29. ry box If you need to install them please refer to Figure 2 12 to simply fasten them to the front right and front left mounting ears with the screws provided Figure 2 12 Attaching the ears and handles ACP 2320MB User Manual 14 Operation This chapter introduces the sys tem operation information Sections include E The front panel The rear panel E Replacing the cooling fans Cleaning the filters E Replacing the power supply 3 1 The Front Panel The front panel features the lockable door four LED indicators a dual USB port and a PS 2 connector The user can close the door with or without the key with the user friendly rotary lock When opening the door there is a momentary power switch a system reset button and an alarm reset button Specific functions are described as below Qs HL E e 8 nu Figure 3 2 Front panel with door open 3 1 1 Switch buttons and I O interfaces Momentary Power switch Press this switch to turn the system power on or off Please
30. s 27 Table 5 1 LED 27 5 2 7 Power Consumption 27 Connectors and Switch Setting 28 Table 5 2 Hardware Switch 28 Table 5 3 1 28 Table 54 cs dde d dh dee iia aes 29 Table 5 5 SWA G iecit bees ei odes 29 Table 50 SWT iicet ebd cd tu e Ld e a cathe 29 Table 5 7 29 Board Layout aldea 30 Figure 5 1 Connector locations of SAB 2000 30 INEST 30 Table 5 8 _ sse 30 T ble 5 9 IPMB 1 tto hed faves td d de cunt cnet o GU e ci uid 30 Table 5 10 PSBUS 1 30 Table 5 11 SMB 39V 1 a stet e rd 30 Table 5 12 SMB 3V 2 scr n edente edd e e 30 5 13 1 31 Table 5 14 VOLTA d pa 31 Table 5 15 TRIM dii resta 31 Table 5 16 RDUPG e e dne 31 Table 517 BZ1 2 i d ert adeo tet dd tn edd dun 31 Table 5 18 HDD1 ice e eet rre 31 Table 5 19 AEMRST 1 eec s d ett 31 Table 5 20 FANT1 7 e nete d oce ta i clades 31 Table 521 DEBUG2 idR adu edades dian 31 Table 5 22 id si as ed d epa dens 32 viii Appendix A A 1 Appendix B B
31. stic bracket 20 Cleaning the 5 21 Figure 3 8 Cleaning the 222 22 21 Replacing the Power 22 Figure 3 9 Replacing the power supply 22 Dual Slot SAS SATA Backplane 23 Backplane Layout RE lee re desideria x di 24 Figure 4 1 Front side layout connect to the HDD 24 Figure 4 2 Rear side layout connect to the RAID card or mother leforz lob e 24 Connectors amp Pin Definition 24 Table 4 1 HDD connectors and LEDs on front side 24 Table 4 2 SATA cable connectors on rear 24 Table 4 3 CN46 Power 24 Table 4 4 14 Fan 24 Intelligent System Module SAB 2000 Getting Started tendent eiu teda crede 26 Specifications 2 2 e tede ta stt 26 5 2 1 Hardware 26 5 22 DIMENSIONS iue tte ite th t d 26 5 2 3 Sensor Input Specifications 26 5 2 4 System Status Monitoring amp 26 5 2 5 Management 26 5 2 0 Alarm Notification ette anite i ted cate aede
32. tact your distributor or sales repre sentative immediately We have carefully inspected the product mechanically and electrically before shipment It should be free of marks and scratches and in perfect working order upon receipt As you unpack the product check it for signs of shipping damage For example damaged box scratches dents etc If it is damaged or it fails to meet the specifications notify our service department or your local sales rep resentative immediately Also please notify the carrier Retain the shipping carton and packing material for inspection by the carrier After inspection we will make arrangements to repair or replace the unit V ACP 2320MB User Manual ACP 2320MB User Manual vi Contents Chapter Chapter Chapter 1 X N gt 1 5 2 1 2 2 2 3 2 4 2 5 3 1 3 2 3 3 General Information 1 2 ijo tele 2 Power Supply 3 Table 1 1 Power supply options 3 Environment Specifications 3 Table 1 2 Environment 3 Dimension esie E E reed 4 Figure 1 1 Dimension diagram esse 4 System 9 Removing the Top 6 Figure
33. teria LED Beep Normal Normal Redundant power module Keep PWR fail Tam beep Get IPMI amp SUSI _ Blinking Keep Command to search Warn beep HDD Normal Normal Data transferring Blinking Normal gt 500 rpm Normal Keep FAN CPU FAN fail 500 rpm Warn beep Blinking Keep System fan fail lt 500 rpm Warn beep Normal Normal Keep TEMP CPU thermal fail gt 70 deg Warn beep System thermal fail Blinking Keep Thermistor 2 deg Warn beep Alarm Reset Close alarm beep 3 min Push Power off when system fail Other ATX only LED of fail part Warn Note LED color might be different in each chassis EE 5 2 7 Power Consumption 12V 5 25A 27 ACP 2320MB User Manual 5 3 Connectors and Switch Setting Table 5 2 Hardware Switch Label Function SW1 10 Hardware Switch Table 5 3 Connectors Label Function TR1 Thermistor Connector TR2 Thermistor Connector TR3 Thermistor Connector TR4 Thermistor Connector ALMRST1 Alarm Reset Connector IPMB1 IPMI module connector PMBUS1 PMBUS Connector LEBOARD1 LED Board Connector SMB 3V 1 SMBus Device Connector SMB 3V 2 SMBus Device Connector BZ1 External Buzzer Connector HDD1 HDD LED connector PWR1 PSU Power Connector SMB MB1 Main Board SMBus Connector RDUPG1 Power Good Input Connector VOLT1 Backplane VOLT1 Connector FAN1 FAN Connector FAN2 FAN Connector FAN3 FAN Connec
34. tor FAN4 FAN Connector FAN5 FAN Connector FANG FAN Connector FAN7 FAN Connector Note Please connect the fan connectors in the correct sequence If two fans z are being connected The correct method is to connect them into FAN1 and 2 If fans are connected out of sequence Alarm will not function correctly ACP 2320MB User Manual 28 Table 5 4 SW1 3 SW1 Pin1 SW1 Pin2 SW1 Pin3 Cable Status MB FAN CPU TEMP OFF OFF OFF No Connect Disable Disable OFF OFF ON Connect Disable 1 OFF ON OFF Connect Disable 2 OFF ON ON Connect 1 1 ON OFF OFF Connect 2 1 ON OFF ON Connect 2 2 ON ON OFF Connect 3 1 ON ON ON Connect 3 2 Table 5 5 SW4 6 SW1 Pin4 SW1 Pin5 SW1 Pin6 SYS FAN Qty OFF OFF OFF Disable OFF OFF ON 1 1 OFF ON OFF 2 FAN1 2 OFF ON ON 3 FAN1 3 ON OFF OFF 4 FAN1 4 ON OFF ON 5 FAN1 5 ON ON OFF 6 FAN1 6 ON ON ON 7 FAN1 7 Table 5 6 SW7 9 SW1 Pin4 SW1 Pin5 SW1 Pin6 SYS FAN Qty SW1 Pin7 SW1 Pin8 SW1 Pin9 TEMP Qty OFF OFF OFF Disable OFF OFF ON 1 TR1 ON ON OFF 2 TR1 2 ON ON ON 3 TR1 3 ON OFF OFF 4 TR1 4 Table 5 7 SW10 SW1 Pin10 Smart FAN OFF Enable ON Disable 29 ACP 2320MB User Manual 5 4 Board Layout Figure 5 1 Connector locations of SAB 2000 5 5 Pin Define Table 5 8 SMB_MB1 Pin 1 2 5 2 2 S

Download Pdf Manuals

image

Related Search

Related Contents

RCS11 Manual - Comtech EF Data  Page 1 of 5 Le Cannabis 09/12/2007 http://users.skynet.be  Installation - Billiger.de  full catalogue  tecnofibra - Tecnoconcret    CUISEUR VAPEUR Réf : 942574 – CL-CV01X  NS1nanosynth manual 1.0  応急仮設住宅に設置する浄化槽の設計・施工・維持管理等について(協会  CellPipe 7230 Business Gateway 100V Series 7230 BG 1VE.C2000  

Copyright © All rights reserved.
Failed to retrieve file