1.    ambient weather    Fischer Instruments 146 01 Stainless Steel Traditional  Temperature   Humidity Comfortmeter with Synthetic Hair  Hygrometer User Manual       ambient weather    Table of Contents    1l  notroductiOn     eet e ehe trt re tr teet vere E tee er Eres eee 2  2  Installation  Care and Cleaning    ii  rer ee ee rr eee eri er Kiss pk 2  3   Th   ComtortMetet      neo e REFERO ERR SUED ap G i 2  3 1 How the Hygrometer Works                ettet ntn tent enne ho denuo ida cnra dae 2  3 2 Hygrotneter ACCURACY    aie Rr OK GU TERRENO NES RERO FER e E EE ERES 3  3 3 Humidity Glo cT NP 3  3 4 Humidity Maintenance  i e eee torte EE ii ee ae 3  3 5 Dial Thermiometet      o eerte ertet ce den euo i ala eee derives ue 3  Ai  AR CCULACY EM et 4  23   Warranty Information    ri e Pe E RUE ERES GTI E FREIE ERR E veut D Eee EH vest sagsevesdesveed 4  6   Liability BUE CIUS dE 4    omfort              Climatemeter  Hair Hvgrometer svnthetic     gt        Fischer    made in germany    Version 1 0   Copyright 2015  Ambient LLC  All Rights Reserved  Page 1       ambient weather    1  Introduction    Thank you for your purchase of the Fischer Instruments 146 01 Stainless Steel Traditional  Temperature   Humidity Comfortmeter with Synthetic Hair Hygrometer  The following is a guide for  preparation  care and operation of your marine weather instrument     Note  Some of the images are generic and may not match your exact model     2  Installation  Care and Cleaning    To measure exa
2.  screw counter clockwise to decrease the  humidity to match the exact humidity     Do not to breathe on the instrument during calibration  This will affect your results     3 4 Humidity Maintenance    The regeneration of the synthetic hair fibers  wrapping the hygrometer in a damp cloth  is not  absolutely necessary but still recommended for precise measurements once per year     Wrap the entire comfortmeter is a damp warm cloth  do not use steam or hot water   Allow to stabilize  for one hour  The humidity should read between 95 and 98  when completed  If it does not  humidity  calibration can be performed     3 5 Dial Thermometer    The dial thermometer uses a bimetallic strip wrapped into a coil  One end of the coil is fixed to the  housing of the device and the other drives an indicating needle  The principle behind a bimetallic strip  thermometer relies on the fact that different metals expand at different rates as they warm up  By    Version 1 0   Copyright 2015  Ambient LLC  All Rights Reserved  Page 3       ambient weather    bonding two different metals together  the coil bends  causing the needle to move  Bimetallic  thermometers are not as accurate as bulb  mercury or red spirit  thermometers  The dial thermometer  requires no calibration     4  Accuracy    The following table provides specifications for the measured parameters                 Measurement Range Accuracy Graduation  Temperature 10 to 100   F  2   F 2  Humidity 20 to 100   3   2                5  War
3. Disclaimer    Reading the    User manual    is highly recommended  The manufacturer and supplier cannot accept any  responsibility for any incorrect readings and any consequences that occur should an inaccurate reading  take place    The specifications of this product may change without prior notice    This product is not a toy  Keep out of the reach of children    No part of this manual may be reproduced without written authorization of the manufacturer    Ambient  LLC WILL NOT ASSUME LIABILITY FOR INCIDENTAL  CONSEQUENTIAL     PUNITIVE  OR OTHER SIMILAR DAMAGES ASSOCIATED WITH THE OPERATION OR  MALFUNCTION OF THIS PRODUCT     Version 1 0   Copyright 2015  Ambient LLC  All Rights Reserved  Page 4          ambient weather    Version 1 0   Copyright 2015  Ambient LLC  All Rights Reserved  Page 5    
4. ct temperature and humidity  the Comfortmeter must be suspended vertically     Relative humidity is closely correlated to and dependent upon air temperature  so it provides the best  data when not exposed to rapidly changing temperatures  For the best measure of the humidity  avoid  placing the instrument in direct sunlight or in line with strong breezes  Locate the instrument in a  place that best represents the average temperature of the local environment  Avoid outside walls that  might be cooler than average  and avoid direct exposure to heat sources that would be warmer than  average     Avoid use of harsh household cleaners and coarse paper towels  which can scratch the bezel or lens   Fingerprints and dirt may be removed the lenses and bezels with a soft cloth lightly dampened with a  mixture of water and mild dishwashing liquid  Be sure to dry the lens and bezel with a soft cloth  after cleaning     3  The ComfortMeter    The calibration and positioning of the hands are designed to indicate perfect comfort conditions in  room atmosphere  when both hands cross in a limited area of the dial  or the    COMFORT zone        There is no one temperature and humidity condition at which everyone is comfortable  People are  comfortable at a range of temperature and humidity  Research conducted over many years on large  numbers of people by the American Society of Heating  Refrigeration  and Air Conditioning Engineers  concluded there is a range of combined temperature and humid
5. ity that provides comfort to most  people     In general  a healthy room climate is optimized at humidity levels between 45 and 60  rh  Your  personal comfort zone may vary based on your climate  season  body type and activity     3 1 How the Hygrometer Works    The hygrometer measures the indoor relative humidity     The sensor element is a specially treated synthetic fiber whose length is sensitive to the humidity in  the air  For a given tension on the fiber bundle  the length increases with increasing relative humidity   Changes in its length are then magnified with precision gears to display the relative humidity of the  air     In contrast to real hair hygrometers  which must be chemically cleaned and rejuvenated often  this    synthetic fiber model provides the same high precision and fast response time without that required  maintenance     Version 1 0   Copyright 2015  Ambient LLC  All Rights Reserved  Page 2       ambient weather    Hygrometers register the percentage of water vapor present in the air  compared to the maximum  amount that can be present at a given temperature     It is not uncommon to have low humidity reading during cold weather when indoor air is heater  Air  conditioning also removes moisture from the air  The optimum levels are 45  to 50  during  heating and cooling seasons  Low humidity can cause health problems and can be hard on wood  furnishings  High humidity can cause mold or mildew to grow     3 2 Hygrometer Accuracy    Humidity measureme
6. nt is among the more difficult problems in basic meteorology  Accuracy is  difficult to achieve  This sensor is accurate to   3   which only the best hygrometers can achieve     A further difficulty is that most hygrometers sense relative humidity rather than the absolute amount  of water present  but relative humidity is a function of both temperature and absolute moisture content   so small temperature variations within the air will translate into relative humidity variations     3 3 Humidity Calibration    The hygrometer has been calibrated at the factory  Over time  humidity will drift  This small drift is  inconsequential for most applications  and it is rare that a household application will ever require  calibration     For laboratory applications that require exact measurements  humidity calibration is recommended  once per year     We recommend using a sling psychrometer to measure humidity exactly  A sling psychrometer is a  mechanical device that measures wet bulb and dry bulb temperature  which is used to calculate the  exact relative humidity     1  Perform regeneration of the synthetic hair fibers as specified in Section 3 4    2  After regeneration  allow the comfortmeter to stabilize to ambient room conditions for at least  one hour prior to calibration    3  Usea sling psychrometer to measure the exact humidity    4  With a precision screwdriver  slowly adjust the set screw clockwise to increase the humidity  to match the exact humidity  Slowly adjust the set
7. ranty Information    Ambient  LLC provides a 5 year limited warranty on this product against manufacturing defects in  materials and workmanship     This limited warranty begins on the original date of purchase  is valid only on products purchased and  only to the original purchaser of this product  To receive warranty service  the purchaser must contact  Ambient  LLC for problem determination and service procedures     Warranty service can only be performed by a Ambient  LLC  The original dated bill of sale must be  presented upon request as proof of purchase to Ambient  LLC     Your Ambient  LLC warranty covers all defects in material and workmanship with the following  specified exceptions   1  damage caused by accident  unreasonable use or neglect  lack of reasonable  and necessary maintenance    2  damage resulting from failure to follow instructions contained in your  owner   s manual   3  damage resulting from the performance of repairs or alterations by someone other  than an authorized Ambient  LLC authorized service center   4  units used for other than home use  5   applications and uses that this product was not intended  such as outdoor use     This warranty covers only actual defects within the product itself  and does not cover the cost of  installation or removal from a fixed installation  normal set up or adjustments  claims based on  misrepresentation by the seller or performance variations resulting from installation related  circumstances     6  Liability 
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
User Manual - Zift Solutions  Televisor LED de 32/55 pulg. 1080p 60 Hz de Insignia con Roku  Origin Storage 120GB TLC SATA  Kensington iPhone 4 & 4S Back Case  Mail Mgt Manual - Clintel Systems  取扱説明書(PDF)    The ltxkeys Package  Instructions - Horizon Hobby  TB-PSC0021 設置説明書    Copyright © All rights reserved. 