1. Ver 1101 2007 11 01 MMS Alarm system 1 Activate the system Send 000000A 1 SMS to console phone number Confirmation administrator will receive a SMS for confirmation as detector on If any moving object 1 e intruder is detected system will process alarm alert as programmed 2 Release the system Send 000000A0 SMS to console phone number Confirmation administrator will receive a SMS for confirmation as detector off System will not process any alarm alert If any motion is detected 2 2 7 D To Check System Settings 1 You may check and review system present settings at any time Send 000000D SMS to console phone number Feedback example as follows Ver YJ5 3 sound open detector on jpg 320 240 N 111111 M 0932345678 0935111111 E judyt yahoo com peter hotmail com H 110 0938666666 2 2 8 T To Listen in Sender can assigned any phone set or mobile phone number followed command T 1 User with phone number 0923999999 intends to listen in the premise Send 000000 T0923999999 SMS to console phone number In 1 minute system will call the phone number received for the user to listen in the premise 2 2 9 00 89Supervise the Site Send 00000002 SMS to console phone number 000000 is default password the 7 show Console Console will process SMS received take two pictures and then send to caller and first email address programmed 2 2 10 C To Reset the System 1 To clear all present sy
2. in power 6V and turn on Console sounds a beep and 3 beeps around 15 seconds later to indicate system is ready If 3 beeps not heard remove the power check re insert the SIM and re power after 3 minutes 4 Follow the examples to program system in flash Key in 000000 M 0932345678 0935111111 0930333333 Epeter hotmail com Send this short message to console phone number Confirmation administrator will receive a SMS for confirmation as M 0932345678 0935111111 0930333333 Epeter hotmail com to indicate programming is successful 0932345678 represents this is the administrator phone number 09351111111 and 0930333333 are general user Note Administrator does not need password to program and operate the system password is necessary for other user s to perform the work Refer to Section 2 2 2 for details d Buen o TUTO ande address 0 disable strobe H Program emergency emergency 1 1 Activate Ver 1701200 __ _ A AIAA D Check System Settings U Ext unit alarming C Default settings reserved func 00 89 Supervise the Site J1 JO 320X240 480X320pixels MMS Alarm system 1 You must well know the commands in the table to operate the system SMS format Password Command1 Setting1 Command2 Setting2 2 Setting example N To Program Password console default password 000000 Send 000000N111111 SMS to console phone number Confirmation user will receive a SMS for confirmati
3. the line is through Meanwhile all receivers of designated phone and email address will have picture of premise and vocal emergency alarm alert as well If line is not through system will terminate alerting after 5 attempts of calling in 3 minutes of time interval Refer to Section 2 2 5 for details of programming emergency alarm receiver and Section2 3 1 for remote control unit operation 2 1 4 Listen in You just need to send the SMS to the console and you will receive call back for the receiver to listen in the sound of premise You can send SMS T telephone number or mobile phone number in one minute console will phone the number behind of the T Users receive they can monitor the voice of the scene Send SMS T console will call the mobile phone number which send SMS 2 2 Commands Comma Function Comman Function nd N Program ee bt ee eee receiver phone M address 0 disable strobe alarm receiver 0 Release D Check System Settings Check System Settings T Listen in U Ext unit Default settings alarming reserved func 00 89 Supervise the Site J1 JO 320X240 480X320pixels You must well know the commands in the table to operate the system SMS format Password Command1 Setting1 Command2 Setting2 In each SMS you can combine commands to perform single or multi programming Beware of that previous setting will be overlapped and invalid by new setting automatically Cautions Ver 1101 2007 1
4. zone and electromagnetic area 7 System should avoid facing transparent window directly 3 2 Data Transmission and MMS Activation Refer to last section 3 9 Ital data transmission is activated In addition the phone set should be programmed properly for GPRS MMS SMS operation Due to difference of telecommunication service providers and mobile phone models please consult with service provider for programming 3 3 Notes for Console s SIM H Esite supervision is frequently used ptease setect the higher packet rate of tetecommunication service If not frequently use basic rate will be enough to cover 2 For saving on telecommunication disable the feature of Caller ID of console If so only SMS can operate and program the system 3 Before inserting the SIM to the console unnecessary features i e voice box and call waiting should be disabled at a mobile phone Insert the SIM to any mobile phone and contact service for correct procedures 4 Refer to user instruction of mobile phone to disable the PIN for the SIM 3 4 Solution for Password Forgotten If the password is forgotten or missing you may follow the steps to reset the password 1 Press and hold the Disarm Test button on any registered the remote control unit for 3 seconds a long beep is heard to indicate system is entering test mode 2 Short the pins at the connector shown as the following drawing with a conductive object such as a screw driver a long
5. 1 01 MMS Alarm system perform programming If administrator and user s are assigned password is not required for administrator and necessary for other user s SMS should be keyed either in English or Chinese Maximal up to 140 characters for English and 70 characters for Chinese compose the SMS command list which includes characters numbers and symbols While programming email address only lowercase is decodable for email address entry Other than comma is used as a separator in a command list space and asterisk can be used as separators as well GPassword is composed of 6 digit numbers 0 9 Maximal up to 5 receiver phone numbers 3 email addresses and 5 panic alarm receivers can be programmed respectively Even though separator is not a must during two different commands we strongly recommend to use separator between the commands In contrast separator is mandatory for the setting such as phone number after the command if setting is more than one While programming email address only English letter number and underscore are acceptable Semicolon is used as prefix and suffix of command list for email address programming Comma is used to divide every email address if email address for programming is more than one and used to close email address entry Max up to 3 email addresses can be stored into system newly programmed email address will clear and overlap prev
6. 1 Buttons 1 Arm 3 Testing 2 Disarm 4 Emergency call Button 1 Arm You should operate the remote control unit within 100 meters transmission range to arm the system Once the button pressed the console will sound continuous high low beeps and system enter armed mode after 1 minute Button 2 Disarm You should operate the remote control unit within 100 meters transmission range to disarm the system Once the button pressed the console will sound a long beep and system enter disarmed mode Button 3 Testing You should operate the remote control unit within 100 meters transmission range to Disarm the system Once the button pressed the console will sound beep a twice and system enter disarmed mode If press and hold the button for 3 seconds system will enter or exit factory testing mode Testing is only for factory inspection purpose not for end user Button 4 Emergency Call Press and hold the button for 3seconds to start the emergency number you preset If it is answered the host will display the pre record voice message to give the warning Ver 1101 2007 11 01 MMS Alarm system If you are not able to operate the remote control unit s normally after system resetting or adding new one s you need to re enroll the remote control unit s to system Instruction is shown as follows 1 Power the system turn on power switch and wait for system initialization completed 3 long beeps heard 2 After system init
7. 9 0938666666 to indicate programming is successful Emergency alarm alert would be active only when the receiver s is designated 2 To deactivate or delete the panic alarm receiver s Send 000000H SMS to console phone number Confirmation user will receive a SMS for confirmation as H Deleted to indicate programming is successful Note a 119 is local emergency line and should be authorized by related department such as police station before programmed b Strongly recommend not to program receivers who live within same premise Thus intruder would know that owner has initiated emergency call when user s phone rings Note When setting the emergency call as 110 please be careful to use emergency call must prevent false alarm and has to g get approval of local police you can have 5 emergency call numbers it will be dialed sequencially follow the setting you made until the phone number you set has been pick up or hang up or it will re dail for 10 cycles Emergency call number is not proper to set user s own mobile number to avoid reminding the criminals at the site it s better set as 110 or your relative not at the site 2 2 6 A To Activate Release the System You can Activate Release the system by sending SMS or using remote control unit when you are leaving the premise Arming or disarming is to activate or deactivate the built in heat amp motion detector Refer to Section 2 3 1 for the remote control unit Operation
8. 9 00 89Supervise the Site ccc cee eee ee ene EE EEE EERE EERE EEE rro rr rn EEE EEE EEE EEE EEE EE 10 222 10 Ci To RES the Systemi ad e hacky 10 2 2 11 U SMS extension unit alarming 0 ccc ccc cece en enn nn nee nee EEE EEE EEE EdEE EEG EetEEEE EEE EEE ES 10 2 2 12 J1 JO 320X240 480 X320 pixels i 0 0 cece cece cece cee cece een en eee enn raro EOE AT ne Eee ne ea een Eee ed 11 2 3 Remote Control Ulla ad nda 11 2 BUS iii A A A da 11 2 3 2 El DEUE as dd cid 11 IINOLES ainia aio sous eilew cas da RNA ATA IAN Gel sasha ATRA 12 35 Location for the System A A A da ed 12 3 2 MMS PEO roads 12 3 3 Notes for SIM Card si revenoriouris unrin r rapist cepa e inari tE TEEPE ea E dla ed a 13 3 4 Forgotten Password oooooooccocconnconnconcon cnn nro rra rro E AE EEE EEE EEE EEE EES 13 ON 13 326 Installation Location A A data beds Ver 1101 2007 11 01 MMS Alarm system 13 3 7 About Heat Detection 2 0 0 c cece cece cece A EE ERER A EE EAEEREN A e E EE EE E En ERS 14 38 About Motion Dti T A E A dea 15 3 9 MMS ACCESS METHOD FOR G80 sisssnusrunnnssssesssrrerrerorssrrreeressersrrerterertreseresssetsreorereesssseesre 15 Quick Programming 1 Installation 1 Insert SIM card which MMS is activated without PIN code Mitral SIM Card Holder 2 Select location where signal strength is strong for communication mount the console and adjust camera lens to proper position 3 Plug
9. MMS Alarm system G80E GPRS MMS Alarm System Real time Audio and Video Wireless monitor and control Ver 1101 2007 11 01 MMS Alarm system Contents QUICK PFOSTAMMING so cosenccscssce s caiessecaccdsess Err es oon ds evesslaesedss eevasseseeeaesesiesseeeveeeseseedesesseaveseevesed 1 General information osiris EEKE O NEE SAE ETE VAAS TaESA 5 NAS 5 LEDESMA a 5 13 ADOU TS Con Slds 5 l 5 Specifications csi A A ia 6 DOMEKALION a REO 6 E ET o A E A EEE EE ET S E E 6 2 121 Active reviewing function sr ei A oes E EAA EEEO ARENA ER 6 2 1 2 Infrared Heat amp Motion Dual Tech Detection occ ccc cc cence nee ne eee ee ene ene ea eneeneeneeeeeeeneenenas 7 2 1 3 Emergency call help Key csc c ccessceceiecas chcetesedeecbevtevacsdenseened ovaevteetestebenpedstecneateoseasdaeetenteene 7 SIN a NAO 7 2 2 Commands ii Na tad 7 Sel N To Program Password usos Aida 8 2 2 2 M To Program Receiver s Phone Number ooooocccccnconconcnnonnonconconcnnonnonno nro rca nono ncnnina nc nc ARTEEN 8 2 23 E To Program Emal Address NS 9 2 2 4 S To Siren ON OFF switch 20 00 00 cece cece nee c cence eee ene nee nc een eens eee eee eneeeeeneeeeaensniereneeaeeneeneeas 9 2 2 5 H To Program Emergency alarm Receiver Phone Number s cceceeceeeeneeeeeeeeeaseeeaeeeeneeneens 9 2 227 D To Checks System Settings sass inene eds o A e DEIN seeped sed enguemeasadend aude t 10 222 8 Te TO LISTENIN erriei rer t Eriu A in 10 2 2
10. any The parameters maybe different in different country and different area it depend on the telecommunication company corresponding to the SIM card in G80 New World Access Point APN mms Homepage http mmsc nwmobility com 8002 IP address 192 168 111 1 Login name Password IP Port 9201 explain of the short message 1 000000 is the default password of host monitor 2 g is command character 3 http mmsc nwmobility com 8002 is the Homepage some times call the MMSC URL 8002 as the http port when the port is 80 1t can be ignored 4 192 168 111 1 is IP address Gateway IP address 5 mms is APN APN is abbreviate of Access point name 6 If the port is 9201 it can be ignored but the followed can not be ignored So the short massage above can also be write as 000000ghttp mmsc nwmobility com 8002 192 168 111 1 mms 7 User Name and Password can be ignored if not have but the followed cannot be ignored Ver 1101 2007 11 01
11. beep is heard again to indicate the password has been reset and reverted to default password 000000 3 Press and hold the Disarm Test button on any registered the remote control unit for 3 seconds a long beep is heard to indicate system is back to standby mode 4 Reboot the system for operation or programming Caution Don t short other pins on the connector and touch other metallic object during resetting Ver 1101 2007 11 01 MMS Alarm system Connector P P P P P P PPP P P Oe 3 5 FAQ Q1 System doesn t initialize after rebooting Al Switch off the power remove the power cord the backup battery and check if SIM is inserted properly Re power the system after 3 minutes Q2 The remote control unit doesn t work A2 Check if battery or the remote control unit fails If not reboot the system to solve the question If problem still exist re enroll the remote control unit to the system Q3 System is not working A3 Check if system is in testing mode the bill of console telecommunication paid or PIN for the SIM card does not disabled If none of above condition reboot the system If junk SMS has occupied the memory of system you clear the memory by rebooting the system 3 6 Installation Location obile Monitor is for indoor application Detection range sensitivity and false alarm are decided by the installation location The following are strongly recommend for select
12. con maximum number is 10 units Ver 1101 2007 11 01 MMS Alarm system c Alarm extension unit Camera unit or Detection unit Reserved function future version d Video line digital signal serial port Reserved function future version 1 5 Major Technical Parameters PIC Format JPEG Resolution 320X240 480 X320 pixels Camera View Angle Horizontal 60 Vertical 60 Effective Range lt 20 meters Remote Control Distance lt 30 meters Backup Battery lt 24 hrs depends on battery capacity Working Temperature 0 50 C 32 122 F Relative Humidity 10 90 non condense Il Operation 2 1 1 Active reviewing function 00 User can supervise the site by calling the console or sending SMS to console Instructions are as follows A By Calling Make sure the feature of MMS is activated for both caller and the console You just call the console phone number and console will pick up confirm and hang up the call After taking a picture of the premise console will send the picture to the caller and the first email address if any email address has been programmed If system authority level has been programmed as administrator and other user s only the administrator can perform this feature by calling and sending SMS plus password for other user s B By Sending SMS Format 0X 0 zero command for sending picture of premise X quantity of picture required to review from to 9 Ex Send 00000002 SMS to console ph
13. eep zone A of lens in function If location is lower than human height no adjustment is needed Fig 5 and Fig 6 indicate how the detection zones distribute and range they are measured under conditions of installation at 2 meters high angle 6 downward and the moving object is over 1 meter tall with heat radiation Side View Top View 3 8 about Motion Detection Motion detection technology is based on the difference between the images of previous and present pictures shot by the built in infrared camera The camera and heat detector have the cone shape view angle of 60 Only if the heat and motion detection devices are triggered at the same and then the system will process alarm procedure This advanced technology is to provide higher accuracy and to prevent false alarm 3 9 MMS ACCESS METHOD FOR G80 Firstly make sure that host monitor is in the test mode Secondly send short message to the host monitor as following form to finish the ACCESS Establishment Short message form Password g Homepage PORT IP address APN IP Port User Name Password Ver 1101 2007 11 01 MMS Alarm system Be careful that Content in bracket is default number it is ignorable if not have The can not be ignored eg The Establish content of short message for New World of HONG KANG 000000ghttp mmsc nwmobility com 8002 192 168 111 1 mms 9201 The short massage content reference to parameters provided by telecommunic ation comp
14. has been triggered you can receive the messages on your mobile with following SMS No 2 give alarm Video extension is giving image alarm messages 2 Extension units must do the channel matching with the console before use it s similar with the way we did for the remote control unit 3 Put the two pins under the mark under the console make them short circuit one touch each other and released you will get a beep sound Mo the console then switch ON the power of extension unit in 15 sec It response when you get a long beep from the console means the channel matching is success 4 The installation environment of extension unit is the same as the master unit but the distance between master and extension unit can t not over 80 meters 80 meters without any thing blocked radio wave will be affected by the environment and the distance Ver 1101 2007 11 01 MMS Alarm system 111 Notes UI ANS e RRS signal before installing You may use your mobile phone with signal strength indicator to check if signal strength of location is strong or not 2 Electricity power AC110 220V should be easy to access 3 System is designed for indoor application not for outdoor 5 System should avoid facing the direct sunlight or being blocked by other object 6 System should avoid facing the area and passage of pets and sun light A A A Steen A Be 4 Location should keep away from air conditioner outtake steamy area heat
15. ialization use a conductive object i e screw driver to short 2 pins locati as sign pointed and circled at the drawing below and remove the object immediately after a short beep is heard Within 15 seconds press any button continuously to register the remote control unit to system You may stop pressing the button when a long beep is heard to indicate the remote control unit registration successful Connector 4 P P P P P LEP LP LPL P P P P PPPPP 1 Follow the steps above to register all the remote control units up to 10 to system 2 If any remote control units is lost you may delete all registered remote control units instruction as below and follow the steps above to re register the rest remote control units to system again 1 Use a conductive object i e screw driver to short 2 pins located asy sign pointed and circled at the drawing above 2 Remove the object immediately after a long beep is heard 3 Follow the remote control unit registration procedure to re enroll them to system 4 System should be rebooted after all remote control units are registered 2 4 Extension unit operations Reserved function for future version While you have the console you still can install the extension units within the effective distance extension units has SMS unit and Video unit two different types 1 SMS unit is to give alarm massages through SMS see2 2 11 U SMS alarm settings For example 2 extension alarm
16. ing location and installing the system 1 Sensitivity of heat detection is decided by the direction of the moving object If the object is moving towards to the lens of the console sensitivity of heat detection will be less accurate than moving cross the zone Toward _ Less Sensitive Cross Sensitive Fig 1 2 System should face potential cross passage of moving object 3 Recommended height for installation is 2 0 2 2 meters to cover maximal detection area 60 ie gee oe A A o y Y de e BaT AEA io io sel gt pa 0 4M gt 12M E 4 Console should keep away from air conditioner refrigerator heater gas burner or some other heat radiation source which will affect detection sensitivity and cause false alarm 5 Console lens should not be blocked by blockades such as shield plants or other furniture Ver 1101 2007 11 01 MMS Alarm system 6 Console should avoid facing window directly which outdoor air flow or other moving object will cause false alarm Before arming the system pull curtain or blind to cover the window for better performance 7 Console should avoid the location of high density RF heat radiation or strong air flow Facing Sunlight Heat Source Outdoor Application Blockade 3 7 about Heat Detection Multi Zone Lens Face elbow and arm have stronger heat radiation than lower potion of human body If location is higher than a human height console should adjust downward to k
17. ious email address settings automatically Format is shown as follows Eemail email email If you program phone set not mobile phone as receiver the system will just send vocal alert message instead of the pictures of premise when alarm occurs Refer to the following examples for detailed instruction for programming System Default Password 000000 2 2 1 N To Program Password To change default password 000000 to preferable code 111111 Send 000000N111111 SMS to console phone number Confirmation user will receive a SMS for confirmation as N 111111 Password is not necessary if operate or program the system from administrator s mobile phone it is mandatory for other programmed users Password is located at the front of any command list if programmed user is intending to operate or program the system 2 2 2 M To Program Receiver s Phone Number 1 To program administrator phone number 0932345678 and user phonenumber 0935111111 as receivers Send 000000M 0932345678 0935111111 SMS to console phone number Confirmation user will receive a SMS for confirmation as M 0932345678 0935111111 to indicate programming is successful 2 To delete all programmed phone number s Send 000000M SMS to console phone number Confirmation user will receive a SMS for confirmation as M deleted If none phone number is programmed as alert receiver any mobile phone with feature of MMS activated can perform site supervision l
18. istening in etc 2 2 3 E To Program Email Address Ver 1101 2007 11 01 MMS Alarm system Email address programming should be performed individually not allowed to combine with other command in a single SMS 1 To program alert path to designated email address july yahoo com amp peter hotmail com from a user mobile phone Send 000000Ejuly yahoo com peter hotmail com SMS to console phone number Confirmation administrator will receive a SMS for confirmation as E july yahoo com peter hotmail com to indicate programming is successful 2 To Delete Programmed Email Address from user s mobile phone Send 000000E SMS to console phone number Confirmation administrator will receive a SMS for confirmation as E deleted to indicate programming is successful 2 2 4 S To Siren ON OFF switch 1 To activate siren and beacon Send 00000081 SMS to console phone number Confirmation user will receive a SMS for confirmation as sound open to indicate programming is successful 2 To Delete siren and beacon Send 000000S0 SMS to console phone number Confirmation user will receive a SMS for confirmation as sound close to indicate programming is successful 2 2 5 H To Program Emergency Alarm Receiver Phone Number s 1 To program police station 119 and 0938666666 as emergency alarm receivers Send 000000H119 0938666666 SMS to console phone number Confirmation user will receive a SMS for confirmation as H 11
19. ite for immediate identification It meets various demands from sectors of household office factory stores etc T Z Features T IR thermo image monitoring and detection for moving objects the double detection technology can eliminate the false alarm caused by environmental reasons 2 It has real time mobile AV alarm and e mail video image back up receiving model 3 You can monitor the site by mobile phone at any time 4 You can use mobile to monitor the voice at the remote site 5 Alarms will activate the pre recorded voice messages and inform the users immediately 6 Easy operate with a wireless remote control device by simple mobile instructions 7 You can setting if the siren and beacon device to be activated when alarm happen 8 Under emergency situation EMSD key can silently inform any designated users 9 With build in back up battery device can be still operating during power failure 10 With IR night vision camera it provides full time 24 hours day and night monitoring function 1 3 About the Console Ver 1101 2007 11 01 MMS Alarm system Antenna gt gt Battery cover Thermo Detector Mounting buckle p gt Flash Speaker Microphone p Video output Serial port a Consol x 1 e Antenna x 1 b Power adaptor x 1 f Remote Con X 2 c Rechargeable battery x 1 g Instruction Manual x 1 d Universal mounting kit x 1 h Warranty card x 1 2 Options a Enhanced antenna b Remote
20. o caller and the first email address programmed to indicate Ver 1101 2007 11 01 MMS Alarm system programming is successful D To Check System Settings Send 000000D SMS to console phone number Confirmation user will receive a SMS for confirmation as Ver YJ5 3 sound open detector on jpg 320 240 N 111111 M 0932345678 0935111111 E judy yahoo com peter hotmail com H 110 0938666666 T To Listen in Send 000000T SMS to console phone number In 1 minute system will call the phone number received for the user to listen in the premise General Information 1 1 Introduction G80 Mobile AV monitor is a brand new Hi Tech product in the wireless communication era it has integrated 2G amp 3G mobile transmission technology and IR image monitoring and thermo detection such kinds of security technologies It has breaking thru the limitation of conventional CCTV system that transmitting by hardwire cable modem which is difficult to install and has higher cost and limited by the installation environment it also has problem of easy to be invaded This product combines the future mobile user s needs to let any mobile phone user must have GPRS MMS SMS function can use their mobile s AV and mailbox function to back up the image information to avoid the destroy of evidences can real time receives the alarm messages from any remote location by the AV Monitor devices or monitoring the real time voice and image from the s
21. on as N 111111 M To Program Receiver s Phone Number Send 000000M 0932345678 0935111111 SMS to console phone number Confirmation user will receive a SMS for confirmation as M 0932345678 0935111111 to indicate programming is successful Send 000000M SMS to console phone number Confirmation user will receive a SMS for confirmation as M deleted E To Program Email Address Send 000000Ejuly yahoo com peterWhotmail com SMS to console phone number Confirmation user will receive a SMS for confirmation as E july yahoo com peter hotmail com to indicate programming is successful Send 000000E SMS to console phone number user will receive a SMS for confirmation as E deleted A To Activate Release the System Send 000000A1 SMS to console phone number Confirmation user will receive a SMS for confirmation as detector on to indicate programming is successful Send 000000A0 SMS to console phone number Confirmation user will receive a SMS for confirmation as detector off S To Siren ON OFF switch Send 000000S1 SMS to console phone number Confirmation user will receive a SMS for confirmation as sound open to indicate programming is successful Send 000000S0 SMS to console phone number Confirmation user will receive a SMS for confirmation as sound close 00 89 Supervise the Site Send 00000002 SMS to console phone number Confirmation console send two pictures t
22. one number 000000 is default password the 7 show Console Console will process SMS received take two pictures and then send to caller and first email address programmed Note 1 If none phone number is programmed as alert receiver any mobile phone with feature of MMS activated can perform this function Only the administrator and user s can do so when receiver phone numbers are programmed Ver 1101 2007 11 01 MMS Alarm system Infrared heat amp motion is active under system arming mode to detect any motion object in the premise If any motion object i e intruder is detected system will send 3 pictures to designated receiver s There is 3 seconds of time interval between the first and second shot the third shot will be sent after the strobe starts to work After sending pictures system calls each receiver and play pre recorded vocal message if the line is through If not system will terminate alerting after 5 attempts of calling in 3 minutes of time interval If new alarm occurrence is less then 10 minutes when first alarm occurred system will only send pictures to the receiver s and no vocal alert will be performed 2 1 3 Emergency call Key Under panic or emergency circumstance such as duress or intrusion you can press and hold the emergency button on the remote control unit for 3 seconds to initiate a silent alarm and alert designated emergency alarm receiver and system plays 3 cycles of vocal emergency message when
23. stem setting and revert to factory default Send 000000C SMS to console phone number Confirmation administrator will receive a SMS for confirmation as factory reset After resetting the system system should be restarted and all the remote units should be registered to the system again before using Try not to use this setting together with other setting operations better do it independently 2 2 11 U SMS extension unit alarming reserved function for future version 1 If you use the monitor extension units 1 for the room 2 for the warehouse operate as follows Send 000000U1 Room Alarm 2warehouse alarm SMS to console phone number Confirmation administrator will receive a SMS for confirmation as u lroom alarm 2warehouse alarm to indicate programming is successful 2 delete the alarm contents Ver 1101 2007 11 01 MMS Alarm system Send 000000U SMS to console phone number Confirmation administrator will receive a SMS for confirmation as U deleted Note One master unit can max connected with 8 extension units Try not to use this setting together with other setting operations better do it independently 2 2 12 J1 J0 320X240 480 X320 pixels Console default pixels is 320X240 Send 000000J0 SMS to console phone number Confirmation administrator will receive a SMS for confirmation as pixels 320X240 to indicate programming is successful 2 3 Remote Control Unit 2 3