Home
Detail Page - University of Engineering and Technology, Taxila
Contents
1. Factory tested Sturdy welded steel construction Ample insulation Two nickel plated shelves adjustable at 12 7 mm 0 5 increments Thermostatically controlled with 14 damper controlled gravity convection air circulation Red pilot light indicates heater 1 action Graygreen hammerloid baked enamel finish Three wire cord and plug standard Capacity Volume 1 m Environmental Light Meter For both indoor amp outdoor purposes Illumination Accuracy at 23 C 5 C 73 4 F 5 F lt 75 R H Sensor Silicon photodiode and filter Measurement rate 2 5 times per second Range 20 200 2000 20000 200000 Lux 20 200 2000 20000 Foot candles Accuracy 3 Calibrated to standard incandescent lamp at 2854 K 6 other visible light sources Angle deviation from cosine Characteristics 30 2 xu 60 6 80 25 Cosine Angular corrected per JIS C 1609 1993 and CNS 5119 general A class Resolution 0 01 fc lux General Specifications Display 3 digit liquid crystal display LCD with a maximum reading of 1999 Zero Automatic Temperature Humidity Operating 10 C to 50 C 14 F to 122 F 0 to 80 RH Storage 10 C to 50 C 14 F to 122 F 0 to 7096 RH Altitude 2000m indoor operation With all accessories Digital Noise Meter Should meet the measurement requirements of Safety Engineers Health Industrial safety offices and quality control in various environments m and C weightings for checking compliance with safety regulations as
2. bidders shall submit separately Technical and financial proposals for qualifying status Following documents must be attached with the technical proposal i Last income tax paid certificate FBR vii GST NTN valid Certificates ii Last GST paid certificate FBR viii No black listing on stamp paper iii Client List ix Bank Statement worth 2 Million iv Work Experience X Company profile ve Relevant Experience T nd of appreciation from previous vi WM Pre MHIDIIeR cs MAD xii Warranty Guarantee Letter The winning bidder shall have to sign a prescribed agreement on the Stamp Paper of prescribed value i e 0 2596 of the total ordered cost duly stamped from notary public Payment will be as per under university rule after receipt of the supply and satisfactory inspection 24 29 26 27 28 The Project Purchase Committee shall have the powers to reject in part or as a whole any one or all the quotations without assigning any reason thereof as per PPRA rules The Tender Relevant documents can also be downloaded from official website www uettaxila edu pk of UET Taxila or can be obtained from the office addressed below For further queries regarding tender bidder s are encouraged to contact visit undersigned in the university working hours Tender Notice can also be seen on website www ppra punjab gov pk Tender submitted without challan form Tender Fee amp earnest money CDR
3. for PM10 PM2 5 amp PM 5 measurement 24 Indoor Air Quality Meter Digital meter for the measurement of indoor air quality 25 Digital Analyzer for SO Range Any Range from 0 2000PPM SO Resolution 1PPM Response Time 20 30 26 Digital Ozone Analyzer Measurement Principle Titration of NO with Ozone with Detection of Ozone Depletion by UV Absorption at 254 nm Precision and Accuracy Higher of 1 5 ppb or 296 of reading Data Storage 14 336 lines 10 s avg 1 4 days 5 min avg 1 4 mo Time Measurement 10 s Data averaging options 10 s 1 min 5 min 1 hr Sample Flow Rate 1 L min Data Outputs RS 232 LCD 0 2 5 V Analog 4 20 mA Optional Flash Card Optional Power Requirements Typical 11 4 watt Maximum 22 3 watt warmup Size 13 3 x 8 3 x 5 3 x in 33 7 x 20 0 x 13 3 cm 27 Digital H2S Analyzer 631 X or Equivalent Range 0 100 PPM Temperature Range 20 C to 50 C I ssued by Prof Dr Saeed Ahmad Project Director SAUG UNI VERSI TY OF ENGI NEERI NG AND TECHNOLOGY TAXI LA STRENGTHENI NG AND UP GRADATI ON OF UNI VERSI TY OF ENGI NEERI NG amp TECHNOLOGY AND ITS SUB CAMPUS Phone 92 51 9047633 Fax 92 51 9047797 Tender Notice The University of Engineering amp Technology Taxila invites bids for purchase of Laboratory Equipment on CIF and Pak rupees basis for Department of Environmental Engineering Industrial Engineering Electrical Engineering Mech
4. well as acoustic analysis m Measuring ranges A Weighting 30 130dB 16 C Weighting 35 130dB 3 m Frequency range 31 5Hz 8KHz m Display with 0 1dB steps on a 4 digits LCD m Slow 1 sec and fast 125ms response settings to check peak and average noise levels m MAX MIN recording m Data Hold to freeze reading on digital display m Accessories supplied Carrying case windscreen user manual and 9V Battery amp all accessories 17 Complete Weather Station 1 Nomenclature Specification Wind speed and direction sensors 3 cup anemometer Reed pulse output Aluminium body IP65 rating Complete with 4 pin IP65 connector for wiring cable not included Supplied with test certificate Wind vane Output 0 1V Power supply 12Vdc 10mA Hall effect position transducer Aluminium body IP65 rating Complete with 4 pin IP65 connector for wiring cable not included Supplied with test certificate Cable 6x0 5 shield External polyurethane price per meter T coupling bar for anemometers diam 50mm complete with fitting for radiant shield and pyranometer supports Thermohygrometers natural ventilation versio Ambient temperature and Relative humidity probe Output Pt100 temperature 0 1V RH96 Power supply 12 Vdc cable L 5 m included Supplied with Calibration certificate Natural ventilation radiant shield Compatibility with DYA046 arm Barom ter Barometer Meas Range 800 1100 hPa Output 0 1Vcc 12Vdc Pow
5. whatsoever the reason may be The tenders shall be opened in the office of the undersigned at the notified date and time The bidders or their representatives can be present if they so desire Only those tenders will be entertained which are absolutely clear unambiguous and legible Any unavoidable cutting overwriting must be signed and initialed The offered items must be brand new and free from any manufacturing defect The University reserves the rights to inspect the working facilities and equipment of the supplier at any stage The items shall be supplied within 45 days of issuance of the Supply Orders A penalty of 0 596 of the total cost or order can be imposed per day for delay on the part of the bidder up to maximum 20 days The University has the right to increase or decrease the quantum of work according to available budget Prices must be inclusive of all freight taxes and duties if any In case of failure in the supply the Project Purchase Committee will have the right to cancel the supply order and forfeit the earnest money and blacklisting In case of delay Project Purchase Committee can provide extension in the date of supply to any bidder s provided valid reasons are given The payment shall be subject to satisfactory inspection report from the concerned evaluation committee and 1096 of the total billed amount shall be retained by the University for a Period Not less than Six Months as Security The
6. RUPEES BASI S Name of Bidder The Equipment to be completed is tabulated as under Bid Security 2 of the Total Cost Total Unit price GST Rs Cost Rs 17 including GST Rs Item s Qty PRI CE SCHEDULE FOR THE EQUIPMENT ON CNF BASIS Name of Bidder Bid Security 2 of the Total Cost Qty Currency Unit Cost Total Type CNF Cost Item s Signature of the Bidder Stamp of Bidder Note In case of discrepancy between unit price and total the unit price shall prevail Issued by Prof Dr Saeed Ahmad Project Director SAUG UNIVERSITY OF ENGI NEERI NG AND TECHNOLOGY TAXI LA STRENGTHENI NG AND UP GRADATI ON OF UNI VERSI TY OF ENGI NEERI NG amp TECHNOLOGY AND ITS SUB CAMPUS Phone 92 51 9047633 Fax 92 51 9047797 Tender Document Part 3 Specifications Nomenclature Specification Quantity Water amp Wastewater Sampler Operating Temperature 32 F to 158 F 0 to 70 C Materials Enclosure Expanded UV protected PVC Bottle 2 5 gallon Polyethylene Pickup Hose 15 reinforced PVC 1 4 ID polyethylene flexible tubing section with intake strainer Pump Tubing Norprene 1 4 ID 7 16 OD Sample Pump Flow Rate 1000 ml per minute at a 4 foot head Type Peristaltic Maximum Lift 20 feet Battery Rechargeable 5 AH Gel Cell Battery Life 1 hour continuous pumping under load Standby 3 months while still retaining e
7. TENDER DOCUMENT TENDER DOCUMENT FOR STRENGTHENING AND UP GRADATION OF LABS OF ENVIRONMENTAL ENGINEERING PAK RUPEES CNF BASIS TENDER NO SAUG ENV 2014 STRENGTHENI NG AND UP GRADATI ON OF UNI VERSI TY OF ENGI NEERI NG amp TECHNOLOGY AND I TS SUB CAMPUS UNIVERSITY OF ENGINEERING AND TECHNOLOGY TAXILA Tel 051 9047633 Fax 051 9047797 UNI VERSI TY OF ENGI NEERI NG AND TECHNOLOGY TAXI LA STRENGTHENI NG AND UP GRADATI ON OF UNI VERSI TY OF ENGI NEERI NG amp TECHNOLOGY AND ITS SUB CAMPUS Phone 92 51 9047633 Fax 92 51 9047797 TENDER DOCUMENT FOR STRENGTHENI NG AND UP GRADATI ON OF LABS OF ENVI RONMENTAL ENGI NEERI NG ON CNF PAK RUPEES Part 1 Terms and Conditions l Please follow the given terms a The firm bidder shall clearly provide the proof of Registration for GST NTN on their printed letterheads b Tender No date amp timing of opening should be clearly mentioned on the top of envelopes Submit your offer for each tender in separate envelopes No tender documents will be received after the closing date time Bids will be submitted on Single Stage two Envelopes basis In case of closed forced holidays tender opening time date will be considered as the next working day Price should be quoted with all accessories It is the responsibility of the supplier to provide all necessary equipment with the basic unit to run the system 2 Certificate showing that the firm has not been blacklist
8. anical Engineering and Electronics amp Mechatronics Engineering from authorized distributors sales agents The details of equipment including specifications are provided in the Tender document s The Tender Document s can be purchased on Payment of Rs 5000 in Habib Bank Branch UET Taxila on prescribed Challan Form Tender Document s can also be downloaded from official website of UET Taxila www uettaxila edu pk or can be obtained from the office address below The Bidders may visit the office of Project Director SAUG during working hours of University The Bids Technical amp Financial on single stage two envelope basis should reach the undersigned not later than 11 00 am on 03 02 2014 The bids will be opened on same date at 12 00 noon in the presence of bidders Prof Dr Saeed Ahmad Project Director SAUG University of Engineering amp Technology Taxila Phone 051 9047633 Fax 051 9047797 Email dr sahmadeyahoo com
9. can be rejected at the time of opening of tender Earnest money amp challan form will be submitted against each tender separately The procuring agency may reject all bids or proposals at any time prior to the acceptance of a bid or proposal The procuring agency shall upon request communicate to any supplier or contractor who submitted a bid or proposal the grounds for its rejection of all bids or proposals but is not required to justify those grounds Tender will be opened in Conference Hall Admin Block UET Taxila at 12 00 noon on 03 02 2014 Prof Dr Saeed Ahmad Project Director SAUG University of Engineering amp Technology Taxila Email dr_sahmad yahoo com UNI VERSI TY OF ENGI NEERI NG AND TECHNOLOGY TAXI LA STRENGTHENI NG AND UP GRADATI ON OF UNI VERSI TY OF ENGI NEERI NG amp TECHNOLOGY AND ITS SUB CAMPUS Phone 92 51 9047633 Fax 92 51 9047797 TENDER NO SAUG ENV 2014 PART 2 SCHEDULE OF REQUIREMENTS FOR THE PURCHASE OF LAB EQUIPMENT FOR ENVIRONMENTAL ENGINEERING The delivery of services and supply will be made in 45 days after issuance of Purchase Order without penalty and with the prescribed penalty as per following schedule of requirement MODE OF PENALTY NO OF DAYS TOTAL DELI VERY PERIOD Without Penalty 45 days 45 days With Penalty 0 5 per day on the delayed 50 days 50 days completion of task 5 days after 45 days 45 05 PRICE SCHEDULE FOR THE EQUI PMENT ON PAK
10. ed or debarred by any Government Department 0 an se 3 Preference will be given to those firms which have their Head Office Branch Office and or Technical Support Maintenance Facilities at Rawalpindi Islamabad or Wah Cantt 4 The specifications of the equipment to be supplied are attached Part 3 of Tender Document 5 The material must be according to specifications 6 The supplier is bound to replace within 15 days all or any part of the equipment found defective during initial inspection by Project Committee The supplier shall provide replacement of defective items parts to the purchaser at UET Taxila main store The supplier shall also remove defective parts item s from Main Store UET Taxila without claiming any additional Cost 7 Offers shall remain valid for 120 days from the date of opening The bidders shall quote their prices inclusive of all duties Taxes Packing Petrol Transportation Installation Demonstration etc and all other expenses on delivery to consignee at UET Taxila premises 8 The sealed bids complete in all respect must reach in the office of the undersigned along with earnest money 2 in shape of CDR to be attached with technical offer 10 11 12 13 14 15 16 17 18 19 20 21 22 23 The sealed tenders complete in all respects must reach the undersigned at the time and date notified in the advertisement Late receipts shall not be entertained
11. er supply Supplied with Calibration Certificate Rain gauge 324 cmq Aluminium tipping bucket rain gauge 324 sq cm inlet area 0 2mm resolution Supplied with Calibration Certificate Cable L2 10 m with connector for analogue output sensors Ground base for rain gauge installation Poles 5 cm for sensors installation 2m meteo pole Stainless steel AISI304 5 cm Base for meteo poles 50 mm fitted on cement plinth Set of n 3 anchoring bolt for pole bases Set of n 3 pickets L 1 m Set of n 3 tie rods for meteo poles E Log dataloggers E Log Environmental Datalogger N 12 inputs n 8 analogue n 2 impulse n 2 on off N 6 digital outputs N 20 programmable intervention logics 16 bit A D converter 2 Mb memory 12 Vdc power supply N 2 RS232 serial interfaces GPRS GSM and Modbus RTU communication protocols Complete with L 2 m cable and USB RS232 converter Removable terminal blocks for wiring Complete with SW 3DOM for Quantity Nomenclature Specification programming and data download IP65 protection box wall or pole installation for E Log and accessories Data sheet MW8012 IP65 box 300x400 mm Includes 2Ah rechargeable battery and 220VAC 24 13 8 V 50W power pack Pole diam 50 mm mounting arm for IP65 protection box 300x400 mm With complete accessories amp Installation of weather station Quantity Digital CO Analyzer for both indoor amp outdoor purposes Temperature O
12. make it functional BOD Reactor It should include Greaseless bottle seals Larger graphic display screen Improved stirring Smaller footprint e Improved procedures with expanded options Bottle fences to prevent tipping of bottles and provide tubing management during storage Auto switching power supply Improved temperature control With complete accessories DO meter Display Dual LCD Nomenclature Specification Range 0 00 to 20 0 mg L ppm Saturation 0 0 to 200 096 Temperature 0 0 to 50 0 C Resolution DO 0 01 mg L Saturation 0 196 Temperature 0 1 C Accuracy DO 1 596 full scale Saturation 0 596 full scale Temperature 0 1 C Salinity Compensation Range 0 0 50 0 ppt Resolution 0 1 ppt Barometric Pressure Compensation Range 555 808 mm Hg Resolution 1 mm Hg Temperature Compensation Automatic from 0 50 C Probe Galvanic with 10 ft cable Memory 16 data points Power Battery on AC Adapter Quantity Electric Shaker Microprocessors PID control maintaining constant speed with clamps for 1000ml Flask beaker Wide speed range 30 to 500 rpm Digital timer with Delayed ON OFF function ranging from 1min to 99 hr 59 min Intuitive splash proof and easy to clean control panel with a vivid and colorful vacuum fluorescent display VFD touch sensitive buttons and a dial knob Automatic adjusted shaking speed when load imbalance or unusual vibration i
13. nough power to run the pump to capacity Start Delay 16 time settings from 0 to 12 hours Composite Interval 15 time settings from 5 min to 12 hours plus an External Trigger mode setting Sample Size 15 composite sample sizes from 50ml to 2 liters plus a Full Bottle discrete setting Approximate sizes at 4 foot head External Trigger Input 250mS minimum pulse width Switch closure or 4 24VDC Pulse Output 5VDC one second pulse 10000hm output impedance Bottle Switch Input Switch closure Input Floating switch in bottle Rain and Water Sensors moisture sensors or switch closure inputs Internal Fuse 10A Slow Blow Size of unit 22x17x9 inch 56x43x23 cm HxWxD Pilot Water Filtration Plant Flow meter 0 1000 Itr h Turbidimeter 0 50NTU 2 Centrifugal pump max flow rate 1000ltr h 1 Solenoid valves piping pump made of corrosion Collecting tank capacity 150ltr each and all accessories to make it functional Portable TSS Apparatus Measuring range 0 001 to 400 g L Operating Temperature Range 0 to 60 C And all other accessories 4 Atomic Adsorption Spectrometer AAS 1 Nomenclature Specification Quantity Wavelength range 190 900 nm Inflamer All metal titanium burner Atomizer Effective glass atomizer Power source 220V 22V AC Flame system Acetylene air burner Nitrous oxide acetylene flame Safety system Can automatically cut off the gas when the pressure is not enough the power is off flameou
14. perating Storage 0 to 50 C 30 C to 60 C Operating Humidity 0 99 relative humidity non condensing Measurement Range 0 to 1000 PPM 18 Measurement Resolution 1 PPM for 0 200 PPM 5 PPM 1 for 500 1000 PPM Accuracy 3 or 2 PPM Recovery time from max concentration lt 1000 PPM 10 seconds Sensor type Stabilized electrochemical Gas specific CO Warm up Self test Period 10 seconds With all accessories Digital CO Analyzer for both indoor amp outdoor purposes Easy to read LCD digital display Compact lightweight and easy installation Highly reliable non dispersive infrared detection method Recorder output signal 19 Automatic control of ventilation systems 1 Alarm contact output provided Diffusion or sample draw versions Meets ASHRAE 1969 IAQ Standard of 2 000 ppm max PEL Detection of CO2 for NFPA 12 Regulations CO2 storage tank leaks With all accessories Digital NO Analyzer Precision and Accuracy Higher of 1 5 ppb or 296 of reading Data Storage 14 336 lines 10 s avg 1 4 days 5 min avg 1 4 mo 20 Time Measurement 10 s Data averaging options 10 s 1 min 5 min 1 hr 1 Sample Flow Rate 1 L min Data Outputs RS 232 LCD 0 2 5 V Analog 4 20 mA Optional Flash Card Optional With all accessories Traffic Volume Counter Measurement with integrated radar detector Collection of single data for 360 000 vehicles number of vehicles direction Speed vehicle classification e g 2 wheele
15. rs cars vans trucks semitrailers distance in seconds 21 1 date time Adjustable for approaching traffic leaving traffic or both directions 6 vehicle classes 10 speed classes data interface RS 232 optional USB adapter speed range from 1 mph to 159 mph 1 km h to 255 km h carrying handle With all accessories 22 Nomenclature Specification Digital Particulate Analyzer PM10 PM 5 and PM 2 5 Six channels and a particle size range of 0 3 um to 10 um Ultra lightweight and ergonomic design for easy single hand operation Ten hours of standard use battery life to last a full work day Large 3 5 inch QVGC color display with backlight intuitive icons and large font options make for easy navigation and viewing 10 000 records stored in device for easy access to historical data Data should be viewed in traditional tabular or trend graph at the user s preference Configurable display sample methods and alarm setting for sample size count raw count per cubic feet cubic meter or liter Data export to USB memory stick or direct connection to PC via USB cable Ethernet enabled for accessing data via internet browser Windows Explorer Safari and Firefox 23 Air Sampler for PM10 PM 5 and PM 2 5 including filters This Portable Maintenance Free Variable Speed High Volume Brushless Blower Air Sampling System for continuous or intermittent sampling with variable flow range Filters
16. s detected by the sensor with all accessories 10 Oil Content Analyzer Measurement principle Solvent extraction NDIR analysis Infrared spectroscopy Measurement range Omg l 200mg l dynamic ranging Resolution 0 to 99 9 mg L 0 1 mg L 100 to 200 mg L 1 mg L Repeatability 0 to 9 9 mg L 0 2 mg L x 1 digit 10 0 to 99 9 mg L 2 mg L x 1 digit 100 to 200 mg L 4 mg L x 1 digit Measurement Automated mixing filtration and measurement Calibration One touch calibration after the calibration standard is introduced to the instrument Display Measured value 3 digits LCD with backlight Message Character display LCD with back light 16x2 characters Functions Data memory up to 50 data points Self diagnostics Stable type display Interactive operation Calendar clock Output RS 232C parallel printer port RS 232C parallel printer port Ambient Temperature 0 to 60 C Dimensions 200 W x315 D x342 H mm 11 Digital Electronic Microscope Microscope with 50000X and 5000X resolution power LCD display 12 Bench top Plate colony Count Apparatus Nomenclature Specification Optics magnified 8X transmission reflection illuminate Counting scope 0 9999 power 10W the size of culture case 90mm or less Digital Balance Quantity 13 Weighing capacity up to 200 kg 1 Incubator For drying baking annealing conditioning sterilizing evaporating and dehydrating
17. t and unconformity of the burner Temperature up to 3000 C Lamps mini eight lamps To measure the trace element of sample Quote all types of trace elements with all accessories to make it functional Country of Origin UK Japan Flame Photometer With 5 channels and be able to detect K Na Li Ca Ba 5 elements With K Na Li Ca Ba five filters which can detect three kinds of elements show three kinds of element content simultaneous Standard accessories air compressor PC software or micro printer LCD Display touch panel with numeric keypad Single point calibration amp calibration curve can be saved RS232 interface external computer or printer With a mist separator Measurement Range K 0 100ppm 5 Na 0 100ppm 1 Li 0 100ppm Ba 0 3000ppm Sample Rate 4 6ml min Response Time lt 8s Time Stability Less than 15 seconds when the sample was taken after the flame Calibration Methods Straight line broken line secondary fitting with all accessories TOC Analyzer Measurement Range TC 0 to 3500 amp IC 0 to 3500 Detection Limit 0 5 ug L Measuring Time 2 3 Min Sample Injection Automatic Injection Sample Injection volume 350 to 20400 ul variable IC pre treatment Automatic internal acidification and sparging Automatic dilution Dilution factor 2 to 50 Gas Consumption Approx 3000 L month NPOC operating conditions 8 hours day x 5 days wk With PC and Gas Cylinder and all accessories to