Home
dsp sine wave home ups manual fusion series
Contents
1. SU KAM OFFICES ADDRESSES BANGALORE H No 449 Ground Floor 7 th Cross 6th Main MICO Layout BTM II Stage Bangalore 560076 Karnataka Tel 080 32961610 41506332 E mail bangalore su kam com CHATTISGARH Flat No 1 Govind Kunj Civil Line Near Jabal Fabricator Raipur 492001 Chattisgarh Tel 0771 3209092 09981541645 DEHRADUN Vedwalia Ward No 15 Bhusa Store Near Shiv Mandir Sharanpur Road Village amp P O Majra Deharadun 248001 Uttarakhand Tel 09999399605 Email dehradun su kam com VADODARA 203 Padmavati Complex Shrenik Park Char Rasta BPC Road Akota Vadodara 390020 Tel 0265 3206250 09974555280 E mail vadodara su kam com JAIPUR 206 Adarsh Plaza Khasa Kothi Crossing SJS Highway Jaipur Rajasthan Tel 0141 4016625 09878694005 E mail jaipur su kam com KOLKATA 8th Floor Room No 14 Shanti Niketan Building 8 Camac Street Kolkata 17 West Bengal Tel 033 32963664 09903114026 Email kolkata su kam com PATNA D 3 Jula Niketan West Boring Canal Road Anand Puri Patna 800001 Bihar Tel 0612 3200776 09934015347 Email patna su kam com BHUBANESHWAR 389 Bomikhal Cuttack Puri Road Bhubaneshwar 751006 Orissa Tel 0674 2585120 09937014979 CHENNAI Old No 87 amp New No 23 Valluvar Salai Arumbakkam Chennai 600106 Tel 044 32984497 09952966135 09940634442 E mail chennai su kam com DELHI WZ 1401 02 Nangal Raya
2. Near Lajwanti Garden New Delhi 110046 Tel 011 32560709 32533361 09971497598 Email delhiservicecenter su kam com HYDERABAD Plot No 81 Syndicate Bank Colony West Marredpally Secunderabad 500 026 Andhra Pradesh Tel 91 40 27717628 09959778881 E mail hydservice su kam com JAMMU Malik Market Channi Rama Bye Pass Road Jammu 180004 J amp K Tel 91 9906908470 9906905009 E mail jammu su kam com MUMBAI 15 RNA Arcade 1st Floor Cross Lane No 3 Lokhandwala Complex Andheri West Mumbai 400058 Email mumbaiservice su kam com Tel 022 40166900 Fax 022 40166905 PUNE 940 2nd Floor Synagogue Street Near Railway Reservation Centre Camp Pune 1 Maharashtra Tel 020 32303900 30523788 09975496268 Email pune su kam com CHANDIGARH SCO 215 217 3 Floor Office No 302 Sector 34 A Chandigarh 160019 Tel 0172 4648509 09878694005 E mail chandigarh su kam com COCHIN Door No 27 77 Plot No 188 8th Cross Road Girinagar Cochin Ernakulam 682020 Kerala Tel 0484 2316141 09995882575 Fax 0484 2316141 E mail cochin su kam com GHAZIABAD 13 7 Site No 3 Meerut Road Industrial Area 3 Near Uttam Toyota Ghaziabad 201001 Uttar Pradesh Tel 91 120 3239910 9810434566 9997797852 E mail ghaziabadservice su kam com INDORE F 47 MIG Colony Near Criestean Eminent School Indore 452001 Madhya Pradesh Tel 0731 3204887 09993590245 E m
3. 124 4170561 566 PKG ML 098 PKG ML 098 N Su Kam mus DSP Sine Wave Home UPS Cae Introduction ett N e Reihe ede 2 KnowingYour DSP SineWave Home UPS ses 2 a Front Patel cts eee eee urere erp 2 7 Bi Back Panel Mc N 7 8 3 Quick Installation Guide eee tetntntnnnnnn 9 10 4 EnhancedFeatu res eere tette bres et e ere eese 10 11 5 TroubleShootirng itinere N 12 13 6 Our Recommendations esee tente ttnentnennns 14 7 Technical Specification eese 15 16 8 Waranty A 17 18 Contents Euu REV 25 04 08 N Su mum DSP Sine Wave Home UPS Mifraduclion b C aimen We feel immense pleasure that you are now proud owner of Su Kam DSP Sine Wave Home UPS Fusion Series designed and developed using state of the art DSP technology The Distinguished Features of Su Kam DSP Sine Wave Home UPS are e Designed Using World s Most Advanced DSP Technology e Runs Computer Along With Other Appliances e User Selector Switch for Computer Air Conditioner Operation e Fuzzy Logic Controlled Five Stage Battery Charger e Dual Selection for Battery Charging e User Friendly LCD Panel e Battery Water Topping Reminder e Smart Overload amp Short Circuit Protection e Automatic Protection For High and LowVoltage e Smart Therma
4. SU e IntelligentThermal Control Su Kam Sine Wave Home UPS senses the overheating and displays the warning with buzzer beep It also automatically shutdown the Home UPS in case of over temperature e Auto Power Saving Fan control system takes care of operation of fan when ever necessary This saves your power andalso enhances the life of fan e AC Mains Cut Out Su Kam Sine Wave Home UPS continuously monitors the AC mains Voltage When AC voltage falls below the preset level the Home UPS automatically transfers from AC to DC power This cut out voltage is Factory preset as Per technical specification mentioned on Page I 5 E hanced GIMMIE REV 25 04 08 eatures 11 IN SU DSP Sine Wave Home UPS mmm ae skaal ing Home UPS mode but no output gt Check the position of rotary switch at DSP Sine Wave Home UPS Toull shooting Buzzer beeps with UPS Temp High gt Check fan at the back panel Shutdown IN SU the back panel gt Check if over temp Shutdown protection is displayed Allow the unit to cool down gt Check if low battery protection is displayed Allow the battery to charge gt Check if overload short circuit protection is displayed Reduce load and switch OFF ON front panel switch Check wiring for short circuit Mains power is coming Home UPS shows MCB trip on its LCD Panel Reduce load and switch ON mains MCB atthe rear panel and
5. restart Home UPS If again the MCB trips then Please check the mains wiring for short Circuit and call our customer care Short circuit protection at the time of installation Input mains is connected to the output of the Home UPS Please check amp correct theWiring Immediately Buzzer beeps continuously with Charging current status changed message is displayed EU Shooting REV 25 04 08 12 Battery Charger status is changed from back panel To activate restart Home UPS else change the position of switch to previous mode amp message is displayed Fanis not Running LCD displays Routine Reminder PI check battery water level amp restart Home UPS along with Buzzer beeps UPS amp allow it to cool down lf problem is repeated continuously Please call our customer care Check the fan status at display panel if fan status OFF then intelligent fan control mode is active ELSE if fan status ON then call our customer care This is a routine reminder that repeats after every 3 months Please check battery water Level do water topping amp restart Home UPS To ignore reset Home UPS Moselle Shooting 13 REV 25 04 08 NY SU DSP Sine Wave Home UPS mmm Que conn con v Never use Automobiles Batteries with your Home UPS They are not suitable for these applications v Always use Deep cycle batteries that are best suited for Home UPS v
6. 140V to 270V Maximum Charging current limit Switch Selectable I2A lA or l6A IA Max Float Voltage Level 13 7V 0 2V Battery Max BoostVoltage Level 14 3V 0 2V Battery Battery Low Voltage Limit 10 0V 0 2V Battery Battery Type 12V SMF Flooded Ded ech Ss Specifications REV 25 04 08 15 IN SU DSP Sine Wave Home UPS mmm ENVIRONMENTAL Acoustic Noise lt 50 dB OperatingTemperature 0to40C Storage Temperature 0to45 C Relative Humidity 0 to 9576 Non condensing TECHNOLOGY DSP based state of the art technology using MOSFETs DSP controlled Fuzzy logic battery charger for optimum charging amp enhanced battery life MECHANICAL Note Due to Continuous product improvement specifications are subject to change without prior notice Sidi m S ecifications REV 25 04 08 16 NY SU Kam DSP Sine Wave Home UPS Model No Serial No Name of Purchaser Address Date of Purchase Dealer s Name P DEALER STAMP E Warranty REV 25 04 08 17 N SU mum DSP Sine Wave Home UPS ums and conditions of warra nly SU KAM POWER SYSTEMS LIMITED warrant to the original purchaser provided the product is st
7. Place the battery charger switch to 12A for 100 150Ah and 16A for 160 200Ah v In case of frequent power cuts or in winters you may switch to 6A charging selection for fast charging of batteries v Always check the water level in batteries when ever reminder for battery water topping after every 3 months occurs This will keep your batteries in good condition amp also enhance its life v Use good quality wires with Input and Output power terminals aAA Recommended wire ratings are Capaciy DCVotage Taput Output Rssery Wire sa fomi 6mm iem Never disconnect battery wires or switch OFF battery MCB while Home UPS or battery charger is operating Qe ELE s REV 25 04 08 14 DSP Sine Wave Home UPS N Su Kem Tekita Specifications MODEL FUSION SERIES INPUT PARAMETERS W UPS Wide UPS Mode Mains AC LowerVoltage Limit 140V 5V Mains AC Lower RecoveryVoltage I50V 5V Mains AC HigherVoltage Limit 270V 5V Mains AC Higher Recovery Voltage 260V 5V UPS Mode Mains AC Lower Voltage Limit 80V 5V Mains AC Lower Recovery Voltage 190V 5V Mains AC HigherVoltage Limit 260V 5V Mains AC Higher RecoveryVoltage 265V 5V OUTPUT PARAMETERS UPS Mode Output Voltage 220V 5 Output Freq 50Hz 0 3Hz Output Freq in Mains mode Sameas Input Change OverTime lt Oms BATTERY PARAMETERS DSP Controlled PWM charging with soft start over full range of mains
8. UPS UPS TEMP NORMAL HIGH f omes In this condition the system gets permanently shutdown but battery keeps charging with 2 3 amps up to Main input voltage 40Volts 9 MainsHigh Cut UPS Switch ON O PVOLT V C OIP FREQ HZ BATTERY V a MAINS HIGH CUT b UPS ON OIP LOAD POWER CUT TIME FAN STATUS ON mni ee A HH MM SS f PSTEMP NORMAL HIG g MODE UPS W UPS This Display shows Mains High Cut protection In this condition the system comes on Home UPS mode and the mains will get cut off The above message keep on scrolling on the LCD panel displaying above parameters one by one till Mains recover 10 Mains High Cut UPS Switch OFF a MAINS HIGH CUT b PVOLT V UPS SWITCH OFF i I P FREQ HZ A c CHARGING CURRENT SELECTION AT 16A FAN STATUS OFF MODE UPS W UPS UPS TEMP NORMAL HIGH f In this condition the system gets permanently shutdown For using Home UPS should be switched ON if the battery is charged BATTERY V oO a y SE Doh O REV 25 04 08 6 DSP Sine Wave Home UPS mm DSP Sine Wave Home UPS N SU Kam l I Charging Current Change With Selection Switch ATTENTION b STATUS CHANGED FROM FRONT PANEL CHARGING CURRENT i RESTART UPS e TO ACTIVATE This is Displayed when charging selection switch at back panel is toggled Restart Home UPS to activ
9. With Buzzer Beep 2 Overload Shutdown Occurred OVERLOAD gt 100 REDUCE SOME LOAD OVERLOAD SHUTDOWN RESTABILUFS This display shows that Home UPS is in Over Load Condition condition See above i e the running load VA on the Home UPS is above the rated system capacity In this case system resets itself automatically and makes 4 attempts to turn ON again If the overload continues even after the 4th attempts it turns OFF permanently condition 2 above and will turn ON after the switch on the front panel is turned OFF and then turned ON 3 Short Circuit Occurred With Buzzer Beep PROTECTION REMEDY SHORT CKT OVERLOAD CHECK WIRING AND REDUCE LOAD AND RESTART UPS This Display shows that Short Circuit has occurred in the Output and Home UPS has gone into Shutdown immediately with continuous buzzer beep Switch OFF the Home UPS Switching OFF Home UPS will stop beeping the buzzer immediately Now remove Short circuit and then switch ON the Home UPS Note Repeatedly switching ON the Home UPS when short circuit is present at the output may damage the Home UPS 2 ud D B REV 25 04 08 4 DSP Sine Wave Home UPS mm mum DSP Sine Wave Home UPS N SU 4 Low Battery Attention With Buzzer Beep ATTENTION REMEDY BATTERY LOW REDUCE LOAD OR SHUTDOWN UPS This display is shown when battery goes down to a limit during discharge It will start displa
10. ail indore su kam com KANPUR 403 404 Gopala Chambar 4th Floor Parade Kanpur Tel 09956295691 Email kanpur su kam com NAGPUR R 2 Near 8 Rasta Chowk Laxmi Nagar Nagpur 440022 Tel 0712 3297252 09975496264 Email nagpur su kam com RANCHI 7AID Plot No 1 Park Road 3 Ashok Nagar Ranchi 834002 Jharkhand Tel 0651 3203277 09934015338 Email ranchi su kam com USER S MANUAL IFU 5207 Serres DSP SINE WAVE HOME UPS Salient Features e Designed Using World s Most Advanced DSP Technology e Runs Computer Along With Other Appliances e User Selector Switch for Computer Air Conditioner Operation Fuzzy Logic Controlled Five Stage Battery Charger e Dual Selection for Battery Charging e User Friendly LCD Panel e Battery Water Topping Reminder e Smart Overload amp Short Circuit Protection e Automatic Protection For High and LowVoltage e Smart Thermal Management e Great Power Saving GLOBAL CERTIFICATIONS ISO 9001 2000 Recognised GOVERNMENT OF INDIA MINISTRY OF SCIENCE amp TECHNOLOGY ISO 14001 2004 N Su Kam www su kam com SU KAM POWER SYSTEMS LTD FACTORY 64 DIC INDUSTRIAL AREA BADDI DISTT SOLAN H P INDIA CORP OFF 54 SECTOR 37 PH VI DISTT GURGAON HARYANA INDIA REGD OFF WZ 1401 2 NANGAL RAYA NEW DELHI 46 Before connecting operating or adjusting this unit please read this instruction booklet carefully Customer care 91
11. ate the changed charging current 12 Over Temp Protection with Buzzer Beep a FAN STATUS ON b PL CHECK FAN AT PROTECTION i UPS TEMP HIGH THE BACK PANEL OVER TEMPERATURE This is displayed when system is overheated 13 Temperature Sensor Fail Condition ATTENTION TEMP SENSOR FAIL 14 After Every 3 Months Routine Reminder is Displayed ROUTINE REMINDER WATER LEVEL amp PL CHECK BATTERY b RESTART UPS B DESCRIPTION OF BACK PANEL 1 Mains Input MCB This isolates mains input from Home UPS 2 Battery MCB This isolates battery from Home UPS 3 Maintenance Bypass Rotary Switch A three position rotary switch is provided for i HomeUPSOutput ii OutputOFF iii Bypass 1 Home UPS Output This is the normal running position when output is fed to the load 2 Output OFF Theoutput of system is disconnected from load 3 Bypass The load is bypassed from Home UPS and is connected to Mains Supply only 4 Battery Charging Selection Switch Selector switch to adjust the battery charger for different battery capacity Set 12A for 100 150 Ah Battery and 6A for 160 200Ah Battery In case of frequent power cut set the switch Position at high charging current 16A to charge your batteries in lesser time S jo amp REV 25 04 08 Bach Desi iU N Su Kam 5 Selection of Switch for UPS W UPS Mode If you want to run PC load select the switch t
12. ill in possession of and used by the original purchaserfromthe date of purchase The warranty stands on all parts except LCD s switches and external body for Home UPS will be for a period of 24 months The warranty will be automatically terminate on the expiry of the warranty period evenincaseofthe Home UPS not being in usein the specified period This warranty is valid only if itis duly signed by the authorized dealer x The warranty will beinvalidif defects arising in company s opinion by reasons of accident abuse misuse neglect improper installation if not undertaken by the company or its representative fire flood or other act of GOD and any other natural calamities and any other unauthorized repairs done or carried out will have to be borne by the purchaser The problem of fuse blown will not be included in the warranty of the product The services given for the same will be paid service The company isin no way or will be held liable for any loss or injury or damage caused to life or property or death and disability caused to any form of life for any reason whatsoever The warranty will not apply if the original seals are found broken or tampered with Free service under the terms of warranty will be provided only by authorized representatives dealers of the company anywhere in India The company expressly denies the right of any person to incur or assure for it any other liability or obligation in connecti
13. l Management e Great Power Saving SSS Selden REV 25 04 08 0 NY SU DSP Sine Wave Home UPS mmm Knowing Your DSP Sie Wists one ups In its most basic form a Home UPS transforms Direct Current DC to Alternating Current AC The battery bank with the UPS acts as a reservoir to ensure continuous supply of power whenever supply from utility power is not available A DESCRIPTION OF FRONT PANEL On the front panel of DSP Sine Wave Home UPS there is one UPS ON OFF switch and a LCD panel PARAMETERS DISPLAYED ON LCD PANEL OF DSP SINEWAVE HOME UPS I Mains not Available amp Home UPS Switch in OFF Condition a SU KAM b MAINS FAIL MAINS FAIL WELCOMES YOU SWITCH ON UPS UPS SWITCH OFF d HARGING CURREN FAN STATUS OFF SELECTIONAT 12A ORI6A UPS TEMP NORMAL 2 Mains not available amp Home UPS Switch in ON Condition Whenever there is no mains amp Home UPS is switched ON Home UPS performs Self Test for once to check the status of the Home UPS If there is any fault Short Ckt Over Load the display shows only the fault after Welcome Note S D po REV 25 04 08 Q DSP Sine Wave Home UPS a SU KAM WELCOMES YOU o DSP SINE WAVE UPS SYSTEM CAPACITY SELF TEST IN PROGESS System checks itself for any fau
14. lation EE REV 25 04 08 Guide 9 IN SU DSP Sine Wave Home UPS mmm NOTE Never disconnect the battery cables while Home UPS is delivering power or battery charger is operating The ON OFF switch has no effect on the charger it turns OFF only the Home UPS To disconnect the batteries for service a Turn OFF the power switch b Disconnect all AC power c Disconnect all the battery cables PO ee F ealures e Battery Management Protocol BMP Su kam Home UPS has highly advanced battery management algorithm that is designed to prevent damage to batteries and extend the useful life of your batteries by regulating the charging voltage and current Batteries can overheat if the charge rate is too high e ATM Charger ATM stands for Auto Trickle Mode ATM with pulse charger is used for the first time in Home UPS ATM with pulse charger charges the battery to its full capacity and after charging it maintains the battery at its float voltage level so the water loss in battery is very less e Auto Reset Su Kam Sine Wave Home UPS has auto reset function in case of Overload Low battery It will reset the Home UPS in fault condition automatically and will make 4 attempts for the same e Automatic Protection Low battery cutout high battery cutout over current and short circuit Insta Mation em Cubance See F hra REV 25 04 08 7eature 10 DSP Sine Wave Home UPS N
15. lt before starting in the following sequence LCD SELF TEST LCD display shows all digits as shown above BUZZERTEST Either buzzer O K or Faulty BATTERY __ i Battery Voltage DSP TEST O K N SU H WRev S W Rev H W and S W Revision SELF TEST PASS If self test fails then restart the system once or twice If still the problem exist call the Service Engineer After TheAbove Messages Following Messages are Displayed in Cyclic Order a e MAINS FAIL UPS ON POWER CUT TIME HR MIN SEC BATTERY V LEE EE LT c O PVOLT V d OUTPUT 000 oiPFREQ Hz C Cau FAN STATUS ON j MODE UPS w UPs UPS TEMP NORMAL OR HIGH The above five message keeps scrolling on the LCD panel displaying Home UPS Parameters one by one in the sequence shown above till Mains Input recovers 3 MAINS PRESENT b a BATTERY CHARGED i Displays Battery status in mains mode Whether Battery is Mains available amp Home UPS Switch in ON Condition charging or Charged VPVOLT __V VP FREQ ___HZ Mains Input voltage amp Frequency HARGING CURREN SELECTION ATI6A IMMI Sea Lh REV 25 04 08 3 NY SU oO a PALTERY CHARGING BATTERY CHARGED FAN STATUS ONOROFF MODE UPS W UPS i HEEEEERERERRER UPSTEMP NORMALORHIGH Under Various Protection Condition I Overload Occuring
16. o UPS mode Other wise keep the switch toW UPS mode DSP Sine Wave Home UPS mmm 6 Input Terminal Block 7 OutputTerminal Block BACK PANEL Back ie REV 25 04 08 i DSP Sine Wave Home UPS N SU Qu Installat ion Guide 1 Mount the Home UPS securely in horizontal position in a clean dry and ventilated enclosure 2 Ensure that the front panel ON OFF switch and battery MCB at the rear panel is in OFF position before you begin the installation 3 Connect the positive terminal of the battery to the positive wire RED of the Home UPS and negative terminal to negative wire BLACK of the Home UPS Immediately check the connections amp switch ON Battery MCB 4 Now connect the Output terminal to the load 5 Switch ON the front panel switch and run the load without AC input Power Place a load on the Home UPS and make sure it works 6 Connect AC input supply to the input terminal such that Line is connected to the terminal marked L Neutral is connected to terminal marked N and Earth is connected to the Earth terminal marked E 7 Switch ON the mains MCB amp Home UPS should now show Mains Present Battery Charging on the LCD After the delay for mains synchronization approx 30Sec the load is connected to mains amp simultaneously the Battery starts charging 8 Now disconnect the AC input power the load should be transferred to the Home UPS mode immediately OT Ins tal
17. on with the sale of Home UPS x Claims if any to this warranty shall be made only before courts having jurisdictionin New Delhi Please send your queries Complaints or Suggestions to info su kam comorCustomercare no 91 124 4170561 566 q SST Warranty REV 25 04 08 18 X
18. ying Condition 4 See above When battery voltage falls below 20 of its rated capacity The buzzer will start beeping and the Home UPS will Shut off after few minutes In this condition Home UPS will make four attempts to restart again and if low battery continues it turns off permanently condition 5 It will turn ON only when ON OFF switch on the front panel is turned OFF and then switched ON 5 Low Battery Protection Without Buzzer Beep PROTECTION BATTERY LOW 6 Mains MCBTrip PROTECTION REMEDY AT BACK PANEL MAINS MCB TRIP SWITCH ONTHE MCB amp RESET THE SWITCH This Display shows when the Mains MCBTrips First Switch OFF The Mains and Home UPS then Switch ON MCB and Reset theSwitch to ON 7 MainsLow Cut UPS Switch ON UPS ON OIP FREQ HZ d O P LOAD 26 POWER CUT TIME FAN STATUS OFF En s 1 i HH MM SS f lUPSTEMP NORMAL HIGH g MODE UPS W UPS This display shows Mains Low cut protection In this condition system comes on Home UPS mode and the Mains will get cut off The above message keep on scrolling on the LCD panel displaying above parameters one by one till Mains recover a MAINS LOW CUT b BATTERY V c O lPVOLT V REV 25 04 08 Jas anal 5 NSu Kam 8 Mains Low Cut UPS Switch OFF MAINS LOW CUT WPVOLT V CHARGING CURRENT a upsswircHorr gt WP FREQ HZ SELECTIONAT I2A BATTERY V e FAN STATUS OFF MODE UPSIW
Download Pdf Manuals
Related Search
Related Contents
(1/2) よくある質問「長期使用製品安全表示制度Q&A」 BSC45R ECN330-switch User Guide Stage Flood Inst QCL 48x10W LED floodlight user manual Au service du secteur public Copyright © All rights reserved.
Failed to retrieve file