Home
SmartLine Guided Radar Level Meter Specifications
Contents
1. SmartLine Guided Radar Level Meter 24 Specifications are subject to change without notice SmartLine is a registered trademark of Honeywell For More Information Learn more about how Honeywell s SmartLine Guided Radar Level Meter can be used for measuring distance level interface and level in a variety of applications visit our website www honeywell com ps hfs or contact your Honeywell account manager Honeywell Honeywell Process Solutions 1860 West Rose Garden Lane 34 VF 03 20 r September 2010 Phoenix Arizona 85027 2010 Honeywell International Inc Tel 1 800 423 9883 or 1 800 343 0228 www honeywell com ps
2. 1 A device with this probe option must be assembled on site For the assembly procedure refer to the handbook or the printed procedure supplied with the components 2 A shorter probe length is available on request 3 1 counterweight option 0 6x3 9 No anchoring solution is available 4 Refer to the end of this section for data about all the probe end options 5 This value is for the 0 5 counterweight If you ordered the 01 5 counterweight 9 6 SmartLine Guided Radar Level Meter 19 Double Probes 1 Double rod 8 mm 0 3 thread and flange versions 2 Double cable 04 mm 0 15 thread and flange versions 3 Coaxial 22 mm G0 9 thread and flange versions 4 Segmented coaxial 022 mm G0 9 thread and flange versions A wide range of counterweights and anchoring solutions are available For dimensional data refer to the pages that follow For installation data refer to the handbook Probes Dimensions mm inches L min 1 L max q t Double rod 8 mm 0 3 1000 4000 25 40 158 1 0 Double cable 4 mm 0 15 2 1000 8000 60 O38 40 315 2 4 1 5 Coaxial 22 mm G0 9 500 6000 20 236 Coaxial 22 mm G0 9 segmented 3 500 6000 O28 20 236 O1 1 1 A shorter probe length is available on request 2 Refer to the end of this section for data about all the probe end options 3 A device with this probe option must be assembled
3. High pressure applications High temperature applications Spray in tank Storage tanks Installation in bypass chamber Small diameter nozzles Long nozzles Stilling wells Interface measurement Solids Powders 7 Granules lt 5 mm 0 1 7 1 Install the device in a stilling well or a bypass chamber 2 Use this probe with an anchor fitting For more data refer to the handbook 3 Max pressure is 100 bar 1450 psig Refer to the pressure temperature table for probe selection 4 Optional Max pressure is 300 bar 4350 psig Refer to the pressure temperature table for probe selection 5 Optional Max temperature is 300 C 570 F Refer to the pressure temperature table for probe selection 6 Max length is 20 m 65 5 ft more on request 7 Max length is 10 m 33 ft more on request SmartLine Guided Radar Level Meter 13 Dimensions and Weight Standard Housing 1 Converter front view 2 Thread version for all probes except the 2 mm 0 08 single cable probe right side 3 Flange version right side 4 Thread version for 2 mm 0 08 single cable probe High Pressure HP version right side 5 Thread version for 2 mm 0 08 single cable probe High Temperature HT and High Temperature High Pressure HT HP versions right side Note e Cable glands are delivered on demand with non Ex Ex i
4. All other probes G 11 2 14 12 NPT Flange versions for single cable 8 mm 0 3 double rod and double cable probes EN DN40 150 in PN16 PN40 PN63 or PN100 others on request ASME 1 8 in 150 Ib 1 6 in 300 Ib 11 2 4 in 600 Ib or 900 Ib others on request JIS 40 100A in 10K others on request Flange versions for all other probes except s ingle cable 2 mm 0 08 EN DN25 150 in PN16 PN40 others on request ASME 1 8 in 150 Ib 300 Ib others on request JIS 40 100A in 10K others on request Other options for single and double rod probes SMS Available on request Tri clamp Available on request Others Others on request Electrical Connections Instrument terminal 1 Non Ex Ex i 14 30 VDC 6 Instrument terminal 1 Ex d 20 36 VDC 6 Instrument terminal 2 Non Ex Ex i Ex d 10 30 VDC 7 Cable Entry M20x1 5 NPT G not for FM and CSA approved devices Not for stainless steel housings M25 x1 5 for stainless steel housings only Cable Gland Standard none Options M20x1 5 for non Ex and Ex approved devices with M20x1 5 and M25x1 5 Cable tightening capacity 0 5 1 5 mm SmartLine Guided Radar Level Meter Material Housing Standard Aluminium Option Stainless steel 1 4404 316L Single rod single p
5. 40 302 F Conduit for remote housing Option Zinc coated steel in a PVC sheath 40 105 C 40 220 F SmartLine Guided Radar Level Meter Approvals CE This device fulfills the statutory requirements of the EC directives The manufacturer certifies successful testing of the product by applying the CE mark ATEX approval for fieldbus ATEX II 1 G 1 2 G 2 G Ex ia IIC T6 T2 outputs pending ATEX II 1 D 1 2 D 2 D Ex iaD 20 or Ex iaD 20 21 IP6X T70 C T95 C ATEX II 1 2 G 2 G Ex dfia IIC T6 T2 ATEX II 1 2 D 2 D Ex tD iaD A21 20 IP6X T70 C T95 C ATEX II 3 G Ex nA IIC T6 T2 IECEx approval for fieldbus Ex ia IIC T6 T3 Ga Ex iaD 20 IP6X T70 C T95 C outputs options pending Ex d ia IIC T6 T3 Ga Gb Ex tD iaD A21 20 IP6X T70 C T95 C FM Dual Seal approved NEC 500 approval for fieldbus output XP IS Cl I Div 1 Gr ABCD T6 T2 options pending DIP Cl I III Div 1 Gr EFG T6 T2 IS Cl VIIIN Div 1 Gr ABCDEFG T6 T2 NI Cl I Div 2 Gr ABCD T6 T2 NEC 505 Cl 1 Zone 0 AEx dfia IIC T6 T2 Cl I Zone 0 AEx ia IIC T6 T2 Cl 1 Zone 2 AEx nAfia IIC T6 T2 Hazardous Classified Locations indoor outdoor Type 4X and 6P IP66 Dual Seal CSA Dual Seal approved CEC Section 18 Zone ratings approval for Drop antenna Cl Zone 1 Ex d IIC Probe Zone 0 T6
6. and Ex d approved devices e Non Ex and Ex i fittings are plastic and Ex d fittings are metallic Non Ex fittings are black and Ex i fittings are blue e The diameter of the outer sheath of the cable must be 6 12 mm or 0 2 0 5 e Cable glands for FM or CSA approved devices must be supplied by the customer SmartLine Guided Radar Level Meter Dimensions in mm and kg Dimensions mm inches Weights a b c D 1 e f g H 2 1 2 kg Ib Housing 180 122 158 5 182 170 197 3 3 7 1 4 8 6 2 7 2 6 7 7 8 7 3 Flange DN25 80 180 122 158 5 182 170 197 123 320 357 4 7 ASME1 3 7 1 4 8 6 2 7 2 6 7 7 8 4 8 12 6 14 1 8 8 15 4 Flange DN100 150 180 122 158 5 182 170 197 123 320 357 7 12 ASME4 8 7 1 4 8 6 2 7 2 6 7 7 8 4 8 12 6 14 1 15 4 26 5 Thread single cable 2 180 122 158 5 182 170 197 144 341 378 4 3 0 08 7 1 4 8 6 2 7 2 6 7 7 8 5 7 13 4 14 9 9 5 version HT HTP Thread single cable 2 180 122 158 5 182 170 197 43 240 277 4 0 08 7 1 4 8 6 2 7 2 6 7 7 8 1 7 9 4 10 9 8 8 version HP Thread all other probes 180 122 158 5 182 170 197 95 292 329 3 7 1 4 8 6 2 7 2 6 7 7 8 3 7 11 5 12 9 6 6 1 This dimension is subject to the size of the cable gland used
7. 2 With 30 kV ESD protection option add 3 9 99mm to this dimension With Metaglas option add 1 7 43mm to this dimension 14 SmartLine Guided Radar Level Meter 15 Remote Housing 1 Front view 2 Left side 3 Rear view Note e Refer to ESD protection and Metaglas dual process sealing system for dangerous products options for the height to add to dimension n Dimensions and Weights in mm and kg Dimensions mm a b c d e f g h i k l m n o p Weight kg Remote 180 109 165 193 98 5 58 21 183 117 150 150 4 100 86 58 60 6 6 version 12 85 1 1 wall bracket 1 4 kg housing support 1 5 kg remote probe housing 2 7 kg flexible conduit 2 m 1 kg 4 5 m 2 25 kg 9 5 m 4 75 kg 14 5 m 7 25 kg Dimensions and Weights in inches and Ibs Dimensions inches a b c d e f g h i k l m n o p Weight Ibs Remote 7 09 4 29 6 50 7 60 3 88 2 28 0 83 7 20 4 60 5 91 5 92 3 94 3 39 2 28 2 36 14 6 version 28 3 1 1 wall bracket 3 1 lbs housing support 3 3 Ibs remote probe housing 6 0 Ibs flexible conduit 6 6 ft 2 2 Ibs 14 8 ft 5 0 Ibs 31 2 ft 10 5 Ibs 47 6 ft 16 0 Ibs SmartLine Guided Radar Level Meter 16 Remote Version Limits For interface and solid powder granulate applications
8. full tank or ballast interface For installation requirements and application needs please refer to the User manual Please refer to the User manual for details of how and where to use these products SmartLine Guided Radar Level Meter y Level Measurement of solids The SmartLine Guided Radar Level Meter has a strengthened 8 mm 0 3 cable probe for measuring powders and granulates in silos up to 35 m 115 ft high The 4 mm cable probe is used for small silos An ESD protection 30 kV option is also available If a product has a very low dielectric constant r lt 1 6 SmartLine Guided Radar Level Meter automatically switches to TBF Tank Bottom Following mode and keeps operating Measurement of liquids in a bypass chamber The SmartLine Guided Radar Level Meter can measure accurately in agitated conditions and in the presence of foam If the tank is full of obstructions such as agitators and reinforcements Honeywell recommends installing the SmartLine Guided Radar Level Meter in a bypass chamber SmartLine Guided Radar Level Meter Level measurement of liquids in a still well You can also install the SmartLine Guided Radar Level Meter in stilling well if there are vortices agitators or other obstructions in the tank It is also suitable for tanks with floating roofs The SmartLine Guided Radar Level Meter setup wizard allows you to quickly configure your instrument to suit specific typ
9. the maximum extension length is 4 5 m 14 8 ft e For liquid level applications the maximum measuring range is reduced according to the length of the coaxial cable between the flange and the converter extension length Extension length Max measuring range or sensor length L m ft m ft 2 6 6 30 98 4 5 14 8 25 82 9 5 31 2 15 29 14 5 47 6 5 16 4 Applications Tank with a lot of vibration e Limited space on the top of the tank or limited access due to the size of the compact converter e Remote display at the bottom of the tank Weather Protection Option lt q ___9_ a b A A o Dimensions and Weight in mm and kg Dimensions mm a b c d Weight kg Weather 208 231 5 268 1 66 2 9 protection 1 radius Dimensions and Weight in inches and Ibs Dimensions inches a b c d Weight Ibs Weather 8 2 9 1 10 6 1 2 6 6 4 protection 1 radius SmartLine Guided Radar Level Meter ESD Protection and Metaglas Options 17 a a b eb 1 Optional ESD protection 30 kV for solid applications 2 Optional Metaglas dual process sealing system for dangerous products The ESD Protection and the Metaglas Options cannot be fitted to the same Device Special Options Dimensions and Weight Options Dimensions mm inches Weights a b kg Ib 99 58 0 85 ESD protection 30 kV 3 9 92 3 1 8
10. 7 43 58 0 83 Metaglas 1 7 92 3 1 82 SmartLine Guided Radar Level Meter Single probes i ITT H i i Y m tdha t m ti n Sq peppe Oo e DEPE m F gt C 3 F iE 18 1 Single rod 8 mm 0 3 thread and flange versions A segmented probe option shown on the right side An optional protective sheath is available on request for the flange version 2 Single cable 2 mm G0 08 the only thread version for the High Pressure HP option and the only thread version for the High Temperature HT and High Temperature High Pressure HT HP options 3 Single cable 4 mm 0 15 thread and flange versions an optional FEP coating is available on request 4 Single cable 8 mm 0 3 thread and flange versions A wide range of counterweights and anchoring solutions are available For dimensional data refer to the pages that follow For installation data refer to the handbook Single Probes Dimensions Probes Dimensions mm inches L min 2 L max m t Single rod 8 mm 0 3 1 600 4000 24 158 Single rod 8 mm G0 3 600 6000 segmented 1 24 236 Single cable O 2 mm G0 08 3 600 35000 100 O14 24 1378 3 9 00 6 Single cable 4 mm 0 15 4 600 35000 100 20 24 1378 3 9 0 8 Single cable 8 mm 0 3 4 600 35000 0 5 O38 24 1378 1 5
11. D protection 30 kV Metaglas dual process sealing system for dangerous products ammonia chlorine 10 Accessories Weather protection 1 optional 2 refer to the Pressure temperature table for probe selection 3 Hastelloy is a registered trademark of Haynes International Inc 4 Hastelloy C 22 2 4602 on request for the 2 mm 0 15 single cable probe 5 others on request 6 min max value for an output of 22 mA at the terminal 7 min max value for an output of 22 mA at the terminal additional power supply needed output only 8 if the ambient temperature is not in these limits the display switches off 9 Kalrez is a registered trademark of DuPont Performance Elastomers L L C 10 Metaglas is a registered trademark of Herberts Industrieglas GMBH amp Co KG 11 HART is a registered trademark of the HART Communication Foundation SmartLine Guided Radar Level Meter Probe Selection Double rod Single rod Single rod segmented Coaxial Coaxial segmented Double cable Single cable 8 mm 0 3 Single cable 4 mm 0 15 Single cable 2 mm 0 08 Maximum probe length L 4m 13 ft 6 m 20 ft 8 m 26 ft 35 m 115 ft Liquids Liquid application LPG LNG Highly viscous liquids Highly crystallizing liquids Highly corrosive liquids Foam Agitated liquids
12. T2 hygienic antenna and fieldbus Cl Zone 0 Ex ia IIC T6 T2 Spul apuone Pending CI I Zone 2 Ex nA IIC T6 T2 CEC Section 18 and Annex J Division ratings XP IS CI I Div 2 Gr ABCD Cl Il Div 2 Gr FG CI Ill Div 2 T6 T2 IS CI I Div 1 Gr ABCD Cl Il Gr FG Cl Ill T6 T2 NEPSI approval pending Ex dia IIC T2 T6 Ex ia IIC T2 T6 CEPEL INMETRO approval pending BR Ex ia IIC T2 T6 BR Ex dfia IIC T2 T6 SmartLine Guided Radar Level Meter 11 Other standards and approvals Continued EMC Electromagnetic Compatibility Directive 2004 108 EC in conjunction with EN 61326 1 2006 and EN 61326 2 3 2006 The device agrees with this standard if the device has a coaxial probe or the device has a single double probe that is installed in a metallic tank NAMUR NAMUR NE 21 Electromagnetic Compatibility EMC of Industrial Process and Laboratory Control Equipment NAMUR NE 43 Standardization of the Signal Level for the Failure Information of Digital Transmitters Construction code On request NACE MR0175 ISO 15156 Options and Accessories Options Integrated LCD display with sun cover 20 60 C 4 140 F 8 2nd current output Remote housing connected to the probe via a flexible conduit Standard lengths 2 m 6 6 ft 4 5 m 14 8 ft 9 5 m 31 2 ft and 14 5 m 47 6 ft ES
13. Technical Information SmartLine Guided Radar Level Meter Specifications 34 VF 03 20 September 2010 The Superior TDR Solution The SmartLine Guided Radar Level Meter is a Guided Radar TDR Time Delay Reflectometry Level Meter for measuring distance level interface level and interface volume and mass A variant with a remote housing can be mounted up to 14 5 m 47 6 ft from the probe The SmartLine Guided Radar Level Meter has higher signal dynamics and a sharper pulse than conventional TDR devices and therefore better reproducibility and accuracy Highlights e Displays level and interface e Configuration software and DTMs included as standard e Optional FOUNDATION Fieldbus and PROFIBUS PA outputs e Optional second current output used for displaying interface measurements for example e High pressure and high temperature versions e Optimal process safety with Metaglas dual process sealing system for dangerous products e Display in 9 languages including Chinese Japanese and Russian e Available in stainless steel and Hastelloy C 22 Other materials are available on request e Angled single cable and rod probes are available on request for installation in tanks which contain obstructions Industries e Chemicals e Petrochemicals e Oil amp Gas e 6Minerals amp Mining e Water amp Wastewater a A O N i 0 Honeywell Figure 1 SmartLine Guided Radar Level Meter Touch screen w
14. be only Refer to the table that follows e Ifh gt d then the top dead zone A1 is equal to the tank nozzle height plus the top dead zone for the probe Measurement Limits in mm and inches Probes Top dead zone A1 Bottom dead Top dead zone A1 Bottom dead dr 80 zone A2 Yr 2 3 zone A2 Yr 80 dr 2 3 mm inches mm inches mm inches mm inches Single rod 200 7 9 10 0 4 250 9 9 50 1 95 Single cable SmartLine Guided Radar Level Meter Coaxial Probe 1 A1 Top dead zone Distance from the flange to the top limit of the measuring range Refer to the notes and table that follow 2 A2 Bottom dead zone Length at the end of the probe where measurement is not linear 3 D non measurement zone Zone where measurement cannot be taken 4 Gas Air 5 Product 1 23 6 L Probe length Length specified by the customer in the order This is also the maximum measuring length for some probe types in direct mode and all devices that operate in TBF mode 7 Tank Height h is the height of the nozzle d is the diameter of the tank nozzle e The dimensions of the tank nozzle have no effect on the top dead zone of the coaxial probe Measurement Limits in mm and inches Probes Top dead zone A1 Bottom dead Top dead zone A1 Bottom dead xr 80 zone A2 dr 2 3 zone A2 dr 80 Dr 2 3 mm inches mm inches mm inches mm inches Coaxial 10 0 4 10 0 4 10 0 4 50 1 95
15. cable 4 mm 0 15 35 m 115 ft For liquids only An angled probe is available on request for installations with very low ceilings or objects in the tank that prevent installation on top of the tank Single cable 8 mm 0 3 35 m 115 ft For solids only Tolerance probe length 1 0 Current Output Output signal Output 1 4 20 mA HART or 3 8 20 5 mA acc to NAMUR NE 43 11 Output signal Output 2 4 20 mA no HART signal or 3 8 20 5 mA acc to NAMUR NE 43 1 Resolution 3 pA Temperature drift Typically 50 ppm K Error signal High 22 mA Low 3 6 mA acc to NAMUR NE 43 PROFIBUS PA Type 4 wire local HART level transmitter Time Domain Reflectometry TDR Function blocks 11 level distance interface level interface distance layer interface conversion ullage conversion layer conversion level conversion level mass and distance mass Protocol Communication Standard PROFIBUS PA protocol that agrees with IEC 61158 2 galvanically isolated Physical layer types Standard power signaling bus powered Other features Bus interface with integrated reverse polarity protection Device power supply 24 V input 18 30 VDC Current consumption on PROFIBUS network 20 mA Output data Level distance interface level interface distance layer interface conversion ullage conversion layer conversion leve
16. de and all devices that operate in TBF mode 7 Tank Height h is the height of the nozzle d is the diameter of the tank nozzle e Ifh lt d then the top dead zone A1 is equal to the top dead zone for the probe only Refer to the table that follows e Ifh gt d then the top dead zone A1 is equal to the tank nozzle height plus the top dead zone for the probe Measurement Limits in mm and inches Probes Top dead zone A1 Bottom dead Top dead zone A1 Bottom dead dr 80 zone A2 dr 2 3 zone A2 r 80 dr 2 3 mm inches mm inches mm inches mm inches Double rod 125 4 9 10 0 4 165 6 5 50 1 95 Double cable 80 is r of water 2 3 is r of oil SmartLine Guided Radar Level Meter 22 Single Cable and Single Rod Probes 1 A1 Top dead zone Distance from the flange to the top limit of the measuring range Refer to the notes and table that follow 2 A2 Bottom dead zone Length at the end of the probe where measurement is not linear 3 D non measurement zone Zone where measurement cannot be taken 4 Gas Air 5 Product 1 6 L Probe length Length specified by the customer in the order This is also the maximum measuring length for some probe types in direct mode and all devices that operate in TBF mode 7 Tank Height h is the height of the nozzle d is the diameter of the tank nozzle e Ifh lt d then the top dead zone A1 is equal to the top dead zone for the pro
17. es of installations and get the best possible performance from it For installation requirements and application needs please refer to the User manual Please refer to the User manual for details of how and where to use these products Remote Display on high or inaccessible tanks If it is difficult or impossible to read the SmartLine Guided Radar Level Meter integrated display at the top of the tank Honeywell recommends the remote display variant It is provided with a cable up to 14 5 m 47 6 ft long and a bracket for mounting in an accessible position If there is vibration in the installation we also recommend that you attach the remote converter to a wall or another safe object that is not attached to the installation For installation requirements and application needs please refer to the User manual Please refer to the User manual for details of how and where to use these products SmartLine Guided Radar Level Meter Technical Data Input Measurement principle Time Domain Reflectometry TDR Parameter Level distance volume and or interface Max measuring range Double rod 8 mm 0 3 4m 13 ft Single rod 8 mm 0 3 4m 13 ft Single rod 8 mm 0 3 segmented 6m 20 ft Coaxial 22 mm 0 9 6m 20 ft Coaxial 22 mm 0 9 segmented 6 m 20 ft Double cable 4 mm 0 15 8 m 26 ft Single cable 2 mm 0 08 35 m 115 ft for liquids only Single
18. essure HT HP versions with FKM FPM and Kalrez 6375 gaskets Ex see supplementary operating instructions or approval certificates 2 HT and HT HP versions with EPDM gaskets 250 C 480 F single cable 2 mm 0 08 probe only Ex see supplementary operating instructions or approval certificates 2 Thermal shock resistance 100 C min Operating Pressure Single cable 8 mm 0 3 probe 1 40 barg 14 5 580 psig subject to process connection temperature and probe type used 2 High Pressure HP version max 300 barg 4350 psig single cable 2 mm 0 08 probe only subject to process connection temperature and probe type used 2 All other probe types 1 100 barg 14 5 1450 psig subject to process connection temperature and probe type used 2 Dielectric constant Er Level in direct mode gt 1 4 for coaxial probe gt 1 6 for single and double probes Interface in direct mode er interface gt gt er level gt gt more than 2 times the value Level in TBF mode 21 1 Vibration resistance IEC 60068 2 6 and EN 50178 10 57 Hz 0 075 mm 57 150 Hz 1g Protection category IP 66 67 equivalent to NEMA 6 6X SmartLine Guided Radar Level Meter Process Connections Thread Single cable 2 mm 0 08 G NPT 2 NPTF for the HT HP version Single cable 8 mm 0 3 G 1 1 NPT
19. iece Standard Stainless steel 1 4404 316L Option Hastelloy C 22 2 4602 3 On request Stainless steel 1 4404 316L in a PVC PVDF or PP protective sheath On request Monel Tantalum Titanium Duplex Single rod segmented Standard Stainless steel 1 4404 316L Double rod Standard Stainless steel 1 4404 316L Option Hastelloy C 22 2 4602 On request Monel Tantalum Titanium Duplex Coaxial single piece Standard Stainless steel 1 4404 316L Option Hastelloy C 22 2 4602 Single cable Standard Stainless steel 1 4401 316 Option Hastelloy C 22 2 4602 only for the 2 mm 0 15 or 4 mm 0 15 single cable probes On request FEP coated stainless steel 20 150 C 4 300 F only for the 4 mm 0 15 single cable probe Double cable Stainless steel 1 4401 316 Process fitting Standard Stainless steel 1 4404 316 L Option Hastelloy C 22 2 4602 On request Monel Tantalum Titanium Duplex Gaskets FKM FPM 40 200 C 40 390 F Kalrez 6375 20 200 C 4 390 F EPDM 50 150 C 58 300 F all probes except single cable 8 mm 0 3 9 Weather protection Option Stainless steel 1 4301 304 Protective sheath On request for single rod only PP 40 90 C 40 194 F PVC 15 80 C 5 176 F PVDF 40 150 C
20. ith 4 button operation 2 wire level meter 4 wire Foundation Fieldbus Housing is rotatable and removable under process conditions 5 different types of probes suitable for a wide range of media Optional ESD protection 30 kV or Metaglas dual process sealing system for dangerous products Same housing for Ex and non Ex Large graphical display Applications Blending tanks Distillation tanks Process tanks Separator Solid silos inventory Storage tanks SmartLine Guided Radar Level Meter Applications Level measurement of liquids The SmartLine Guided Radar Level Meter can measure the level of a wide range of liquid products on a large variety of installations within the stated pressure and temperature range including LPG and LNG It does not require calibration or commissioning when installed A Metaglas option is also available for dangerous products and ensures that no leakage is possible A number of probe end attachments are available For example the user can fix the end of cable probes to heating coils this prevents deposits building up on the probe Interface measurement of liquids SmartLine Guided Radar Level Meter can measure interface with or without an air gap It can also measure level and interface simultaneously It has an optional second analogue output The coaxial probe of the SmartLine Guided Radar Level Meter has a top dead zone of only 10 mm 0 4 this makes it ideal for tracking
21. l conversion level mass and distance mass Input data None Error current FDE Typically 0 mA FDE Fault Disconnection Electronic Address range 0 125 Default address 126 SmartLine Guided Radar Level Meter FOUNDATION Fieldbus Type 4 wire local HART level transmitter Time Domain Reflectometry TDR Function blocks 1 x Resource Block RB 4 x Analog Input Blocks Al 1 x Transducer Block TB Analog Input Block 50 ms Protocol Communication standard Foundation Fieldbus protocol that agrees with IEC 61158 2 galvanically isolated ITK version 5 1 Physical layer types Standard power signaling bus powered non I S Other features Bus interface with integrated reverse polarity protection Device power supply 24 V input 18 30 VDC Bus power supply 9 32 VDC non Ex 9 17 5 VDC intrinsically safe Basic current 20 mA Maximum error current 20 mA Start current after 10 ms 20 mA Polar sensitivity Yes Minimum cycle time 100 ms Output data Level distance level conversion interface level interface distance layer interface conversion ullage conversion layer conversion level conversion level mass or distance mass Input data None Error current FDE Typically 0 mA FDE Fault Disconnection Electronic Link Master function Not supported Reference Conditions acc
22. on site For the assembly procedure refer to the handbook or the printed procedure supplied with the components SmartLine Guided Radar Level Meter 20 Ensure that the transmitters are used within their operating limits Observe the following requirements 300 280 60 40 0 50 Process pressure Ps bar Process connection temperature T C All probes High Pressure HP version of the 2 mm single cable probe High Temperature High Pressure HT HP version of the 2 mm single cable probe High Temperature HT version of the 2 mm single cable probe 58 0 120 210 300 390 480 570 Process pressure Ps psi Process connection temperature T F All probes High Pressure HP version of the 00 08 single cable probe High Temperature High Pressure HT HP version of the 0 08 single cable probe High Temperature HT version of the 0 08 single cable probe SmartLine Guided Radar Level Meter 21 Measurement Limits Double Cable and Double Rod Probes 1 A1 Top dead zone Distance from the flange to the top limit of the measuring range Refer to the notes and table that follow 2 A2 Bottom dead zone Length at the end of the probe where measurement is not linear 3 D non measurement zone Zone where measurement cannot be taken 4 Gas Air 5 Product 1 6 L Probe length Length specified by the customer in the order This is also the maximum measuring length for some probe types in direct mo
23. to EN 60770 Temperature 20 C 45 C 70 F 10 F Pressure 1013 mbar abs 20 mbar 14 69 psig 0 29 psig Relative air humidity 60 15 Accuracy Resolution 1 mm 0 04 Repeatability 1 mm 0 04 Accuracy in direct mode Liquids 3 mm 0 12 when distance lt 10 m 33 ft 0 03 of measured distance when distance gt 10 m 33 ft Powders 20 mm 0 8 Interface 10 mm 0 4 er constant Accuracy in TBF mode 20 mm 0 8 er constant Minimum layer interface 50 mm 2 SmartLine Guided Radar Level Meter User Interface Display LCD 9 lines 160 x 160 pixels in 8 step grayscale with 4 button keypad Operating languages English German French Italian Spanish Portuguese Japanese Chinese Mandarin and Russian Process Conditions Ambient temperature 40 80 C 40 175 F Ex i see supplementary operating instructions or approval certificates Storage temperature 40 85 C 40 185 F Process Connection Temperature Standard 40 200 C 40 390 F according to the temperature limits of the gasket material Refer to Material in this table Ex see supplementary operating instructions or approval certificates 2 High Temperature HT and High Temperature High 300 C 570 F single cable 2 mm 0 08 probe only Pr
Download Pdf Manuals
Related Search
Related Contents
PG Music Band in a Box - 2011 (Windows) Upgrade Manual Eye Gaze Tracking System COOLER VE 253 A++ NF - Migros PEAKS Studio Manual 2.0 - Bioinformatics Solutions Inc. Sony ADP-AMA Marketing Specifications MTD AC3 Automobile Parts User Manual SAVE VTC 700 コンテッサスタンダードメッシュ 取扱説明書 man_Adina 70 S-line_Adina 85 M-line (`12Loes).indd User Manual - Mirai Inter-Tech Copyright © All rights reserved.