Home
C-700 C-700R
Contents
1. __ Over or Under will be displayed if the light source illumination is too bright or not bright enough or if the color temperature is out of the measurement range when the Measuring Button is pressed In this case adjust the brightness or color temperature of light source or switch the light range gt P88 74 5 Measuring Light Sources Measurement Screen Measurement in Radio Triggering Flash Mode C 700R Only The Radio Triggering Flash Mode is a measurement method that triggers flash from the meter wirelessly by connecting to the flash through a radio receiver sold separately This allows a single person to cordlessly perform flash measurement Before taking a measurement you must set the transmitter meter and the receiver to the same radio channel Compatibility with C 700R The PocketWizard Series from LPA and other flash devices equipped with PocketWizard systems are compatible Read the instruction manual of the radio receiver for information about how to operate it For information about compatible devices refer to LPA s website www pocketwizard com e Do not use near industrial scientific or medical devices such as pacemakers The radio waves may affect the operation of pacemakers 9 5 Measuring Light Sources Measurement Screen A CAUTION e Do not use within hospitals and other medical institutions or near medical electrical equipment
2. x3 _ Measurements and display will take longer in light levels below 30Ix The LCD illumination will normally switch off during measurements to avoid influence to measurements Power OFF 1 Press and hold the Power Button for 1 second or longer The meter will turn OFF Q noT oe a __ Please wait 3 seconds between repeated power on and power off sessions lt _ e If the LCD screen shows no display check if the batteries are installed properly Pos Neg positioning and have enough capacity e All settings and measurements made during use are saved in memory even after the meter is powered off 2 Before Use 24 Checking the Battery Capacity When the power is turned ON the LCD screen will show the battery capacity indicator Sufficient battery life remaining Adequate battery life remaining Have a spare battery ready Replace the battery immediately V NOTE m e When battery power is low and the meter is turned ON the LCD screen will appear and then turn off immediately This is an indication that the batteries are depleted and should be replaced immediately Having spare batteries on hand is recommended e When the meter is continuously used at room temperature the battery life should last 8 hours based on Sekonic testing methods 2 Before Use 25 Automatic Power OFF Function To save battery ca
3. 4 Press the Measuring Button to measure Light Selection Ring Turn the Light Selection Ring to select the range When measuring ambient light make sure to select Range L lo When measuring flash units select Range L a or Range H fo depending on the brightness of of the flash gt P86 P88 Measurements can now be made Measuring Button Measurements and display will take longer in light levels below 30Ix The LCD illumination will normally switch off during measurements to avoid influence to measurements 5 The current measurement is displayed in the display area of the screen 6 Touch the Memory Select icon The Spectrum Comp Memory screen will be displayed Spectrum Comp Spectrum Comp Screen Memory Screen Spectrum Comp Target 5000K Memory f Current Measurement 02 LED NO Selection Icon CCT 5587K Auv 0 0129 03 LED NO 3 LED NO 4 05 CCT 4331K Auv 0 0093 LED NO 4 04 Memory CCT 3079K Auv 0 0007 4 Selection Area Title Memory AAAAK AAI 79K 39 4 Setting the Measuring Conditions When the no data is registered in memory a message will be displayed in a pop up screen Memory Selection Pop up Screen Target 5000K Current Measurement CCT 5587K Auv 0 0129 No memorized value No memorized value After you confirmed the message No memorized value touch the Close button Returns to the Spec
4. 5 Touch the Target indication Target CCT screen will be displayed P26 Set the color temperature Measurement Screen Target CCT Screen T 1 125 Target CCT Digital Fy 2500 10000K Target 5000K CCT 5000K Hix Cancel If you are not using LB index filter and CC index filter values you can omit this step You cannot set the target color temperature using the CRI or Multi Lights Mode 6 Connect the sync cord sold separately to the Sync Terminal of the meter Sync Terminal 70 5 Measuring Light Sources Measurement Screen 7 Touch the T Shutter Speed indication on the Measurement screen Set the shutter speed used for measurements gt P24 Match the blue background with the desired shutter speed Measurement Screen Shutter Speed Display Screen ars Ez T 1 125 Target 5000K Fz Target 5000K CCT Hix Shutter Speed Screen Shutter Speed The selected value is indicated by the blue background OK Button Cancel Cancel Button A CAUTION e Depending on the flash equipment used the flash may be triggered when the sync cord is connected to the Sync Terminal or when operating the Power Button Because there is the possibility of burns or negative effects on vision please handle with care Power Button 71 5 Measuring Light Sources Measurement Screen 7 NOTICE e S
5. 9 Appendix _ Description Read as per mega Kelvin this unit is based on the International System of Units and is equivalent to the traditional unit of MIRED mrd It expresses the inverse of the color temperature The inverse of the color temperature is 1 000 000 divided by the color temperature Inverse color temperature 1 000 000 Color temperature The inverse color temperature decreases as the color temperature increases Ex 10 000K 100MK 3200K 312 5MK If a 100K change is applied to both 10 000K and to 3 200K the human eye perceives the change applied to 3 200K as larger In other words there is a difference in perception of the same change in color temperature depending on the color temperature s numerical value When the inverse color temperature is used the human eye perceives a given amount of change as the same for any color temperature MK divided by 10 Because the unit MK is extremely small compared to the amount of change in color temperature the human eye can perceive and because performing corrections is difficult for practical purposes the unit daMK deca per Mega Kelvin is used This unit is also used in conventional filters that change color temperature The difference of the reciprocal of the selected color temperature and the reciprocal of the measured color temperature It is expressed in units of MK equivalent to MIRED or daMK Stands for Light Balancing Filter
6. 3 Press the Measuring Button to measure Light Selection Ring Turn the Light Selection Ring to select the range When measuring ambient light make sure to select Range L le When measuring flash units select Range L a or Range H 1o depending on the brightness of of the flash gt P86 gt P88 The measurement results will be displayed Measurement Results Screen Measuring Button for Multi Lights Filter Brand Filter Name CCi Filter Name CC 1 8 PLUS GREEN Close amp Close Button On the Measuring screen of Multi Lights the Measuring Button is enabled but Memory Button is disabled Measuring Button Memory Button Measurements and display will take longer in light levels below 30Ix The LCD illumination will normally switch off during measurements to avoid influence to measurements 50 4 Setting the Measuring Conditions 4 Touch the Close button The message Set the measured value Are you sure will be displayed Message Confirmation Screen Set the measured value Are you sure Yes Button No Button 5 Touch the Yes button Returns to the Multi Lights screen Measurement results are reflected in the light source A To return to the Multi Lights screen without reflecting the results touch the No button Multi Lights Screen 5587K Measurement results are displayed 6 Measure other light sources for comparison Repeat
7. Displayed when the screen is unlocked meos ei Q H0000 Key Lock Status Indicator Displayed when the screen is locked When the screen is locked touch panel operations are disabled 16 3 Basic Operation Methods __ Tool Box Screen You can perform the following settings by touching the Tool Box EEA icon on the Measurement screen All icons are displayed for explanatory purposes for the Tool Box screen It is not the default Measuring Screen in Text Mode Tool Box Screen p Digital Film Target 5000K 7 Preset Selection Digital CCT ls Preset Selection Film Lux wa Memory Title Memory Clear CCi Memory Recal LB i NOOR WD Radio Channe Zone Ra Indicated only for C 700R model Box Item List Part Name Description s pmm O aomena aee Memory Clear Switches to the Memory Clear screen P104 Memory Recall Switches to the Memory Recall screen P98 Radio Channel Zone only for C 700R model Close Button Closes the Tool Box screen and returns to the Measurement screen Switches to the Radio Channel Zone screen P108 17 3 Basic Operation Methods _ 3 2 2 Icon Operation Touch operation Touch the icons on screen to perform various operations Ex Measuring Screen in Text Mode Target 5000K CCT Lux CCI LBi Ra Touch enabled Icons A blue illumination under icons indica
8. All A D will be deleted and it will return to the Multi Lights screen When the No button is touched the display returns to the Multi Lights screen without deleting the memory No Button 52 4 Setting the Measuring Conditions 4 3 8 Displaying in White Balance Correction Graph WB Corr Mode Displays the difference between the current measurement value and the target color temperature in a white balance correction graph WB Corr Screen Target Indication Measuring Mode Icon Target 5000K A Display Mode Icon WB Correction Disp Displays LB index LBi 21MK 1 E CCi 1 7G Displays CC index WB Graph Displays corrected value BA Step 5 OHK i GH Step 2 5 P 1 Touch the WB Corr icon on the Display Mode screen The WB Corr screen will be displayed P29 2 Touch the Measuring Mode icon The Measuring Mode Selection screen will be displayed Select the desired measuring mode to use P22 3 Touch the Target indication Target CCT Input screen will be displayed P26 Set the desired color temperature number 53 4 Setting the Measuring Conditions 4 Press the Measuring Button to measure Light Selection Ring Turn the Light Selection Ring to select the range When measuring ambient light make sure to select Range L lo When measuring flash units select Range L a or Range H fo depending on the brightness of of the flash gt P86 P88 Measurements can
9. Memory Clear fameeory Clee _ pan Oa a wl E e Memory Recal Memory Recall p Radio Channel Zone p Radio Channel Zone The selected value is indicated by the blue background If no presets have been created the Preset Selection will be grayed out and touching the button will not display the Preset Selection Display You can omit this step if unnecessary 7 Confirm the light measuring range Light Selection Ring When you return to the Measurement screen select Range L fie or Range H depending on the brightness of of the flash Measuring Button e Range L a Select when measuring small and low power flash units lower than 640Ix s Over will appear if flash power is too high Select Range H e Range H e Select when measuring powerful flash units brighter than 640Ix s Under will appear if flash power is too low Select Range L 65 5 Measuring Light Sources Measurement Screen 8 Press the Measuring Button The meter will enter measurement standby mode While the icon is blinking manually trigger the flash The Measuring Mode icon will blink for 90 seconds when measuring The display illumination will dim when the measuring button is pressed as the display illumination can affect the reading This is normal When the flash light is fired the measured value will be displayed for 3 seconds and the display will return to measurement standby m
10. Target 5000K CCT Lux CCi LBi Ra 2 Enter the Target color temperature value The current target color temperature value and the entered value are displayed Target CCT Input Screen Target CCT Digital 2500 10000K Target CCT Digital 2500 10000K Current value 5000K 5000K 520 Input value display display Numeric number input OK Button cancel Cancel Button Cancel 26 4 Setting the Measuring Conditions 3 Touch the OK button Confirms input value and returns to previous measurement screen Touch Cancel to return to the previous measurement screen without setting Target value The target color temperature in Text Mode is set Target 5200K lt _ Setting Target for Digital Mode e Set the meter to the same color temperature set on your camera Please note that many digital cameras reproduce color better at certain color temperature settings If your work requires optimum color reproduction and high color fidelity select the camera manufacturers recommended color temperature for best color reproduction Please refer to your digital camera s operating manual e You can set the color temperature from 2 500K to 10 000K in steps of 10K e When you frequently use multiple reference color temperatures use preset for convenience P92 Setting Target for Film Mode e Set the reference color temperature of the type o
11. y Auto Dimmer ControlTL Standard Sa Not in Use tt Radio System Preference a Reset Customized Items v A Close Cancel 143 7 Meter Settings Setting Screen e 2 Touch the desired system to use Select from 4 options ControlTL Standard ControlTL Standard or Not in Use Radio System Preference Screen ControlTL ControlTL Standard Standard ControlTL Standard ControlTL Standard Not in Use Not in Use Cancel Cancel The selected button will be displayed encircled in blue OK Button Cancel Button 3 Touch the OK button Confirms the settings and returns to Setting To return to Setting without confirming touch the Cancel button Setting Screen t Auto Power Off ty Backlight Brightness Auto Dimmer ito Language t Radio System Preference The set content is displayed a Reset Customized Items v A Close The radio system preference is set 144 7 Meter Settings Setting Screen e 7 2 14 Reset Customized Items Initialize reset only contents of Customize in Setting to the factory default Reset Customized Items Screen 1 Touch the item Reset Customized Items button on page 2 of Setting Initialize the contents of Customize Are you sure is displayed Setting Screen Reset Customized Items Screen a Spectrum Y axis Scale it Auto Power Off Le Backlight Brightness Xt Auto Dimmer Ley Language
12. Light Selection Ring or Range H the brightness of of the flash S EKONIC MASTI C700 ER Measuring Button e Range L g Select when measuring small and low power flash units lower than 640Ix s Over will appear if flash power is too high Select Range H e Range H Select when measuring powerful flash units brighter than 640Ix s Under will appear if flash power is too low Select Range L 82 5 Measuring Light Sources Measurement Screen 9 Press the Measuring Button Measurement will be taken with flash and the light source values will be displayed The display illumination will dim when the measuring button is pressed as the display illumination can affect the reading This is normal Measurement in Radio Triggering Flash Mode is complete A CAUTION e Do not trigger flash while skin or other objects are in contact with the flash tube Do not touch the flash tube after continuous flashes It may cause burns e Do not trigger flash while near the eyes of people or animals It may temporarily affect vision e The flash may be triggered suddenly Because there is the possibility of burns or negative effects on vision please handle with care G noT oE i _ e If the flash output power is too weak compared to the surrounding light the meter may not detect the flash output In this case use 5 4 Measurement in Cord PC Flash Mode P68 e Pulsed light sources
13. Not Selected 01 FL O01 A v 0l O QGK 3 02 5689K k Return to the eo een Screen by Radio Channel Zone Pane Memory Title gt P108 i gt P95 Be Disita e i M1 Digital ff 1 6 a Some iii DigitaljP 1 i j i E Te ry Radio Channe Zone Memory Title LED NO 4_ lt _ ControlTL Channels only for C 700R model 89 6 Measurement Tool Tool Box Screen 6 1 Selecting Digital Film Select Digital or Film in accordance with the type of camera Digital Film Screen Digital Select a button Film Cancel 1 Touch the Digital Film button Digital and Film button will be displayed Tool Box Screen Digital Film Screen y Digital Film Digital The selected y Preset Selection Digital button will p Preset Selection Film ENS be displayed p Memory Title encircled in Memory Clear blue Memory Recall g Radio Channel Zone 90 6 Measurement Tool Tool Box Screen 2 Touch either the Digital or Film button The selected button will be encircled in blue Digital Film Screen Digital Filn Digital Film The selected button will be displayed encircled in blue OK Button Cancel Cancel Button 3 Touch the OK button Confirm and return to the Measurement screen To return to the Measurement screen without confirming touch the Cancel button The selected status will be displaye
14. and refers to a filter used for correcting color temperature in photography A blue filter is used to raise the light source color temperature while an amber filter is used to lower it By using the custom settings in the C 700 C 700R the display can be changed to show the type of the filter brand being used Number that expresses the amount of difference between the G component Green range of the measured light source and the base black body radiation of the color temperature 1CC index is equivalent to 2 5CC filter number Stands for Color Compensating Filter and refers to a filter used for correcting color in lighting There are 6 different types of filters Yellow Y Magenta M Cyan C Blue B Green G and Red R but the C 700 C700R only uses the Magenta M and Green G types 177 9 Appendix _ 9 2 Filter Types When using camera LB CC filters based on the recommended compensation displayed in the meter C 700 series please note that camera lens filters block or absorb light to produce their effect and thus the amount of light passing through them for exposure will be reduced If your camera does not have a through the lens exposure system and you are using a handheld exposure meter to determine camera settings consult the table below to find how much to increase the exposure to compensate for the light absorbed by the lens filter When you use a lighting filter exposure compensation is not necess
15. 1 The technical standard is stipulated in the Ministerial Ordinances Related to Radio Law Ordinance Regulating Radio Equipment Article 14 2 E Intended Users The intended users of this product are the following Those who are engaged in shooting or related businesses such as photographers videographers and cinematographers light operators gaffers and directors of photography In addition lighting engineers of architecture art and interior and those who manage light sources in rental studios and light shops E Restrictions There are some cautions and restrictions regarding the use of this product Please agree to the following contents before use _ _ e The contents of this operating manual may change without prior notice due to specification changes or other reasons Therefore the contents of this operating manual may differ from the operating manual included with the model you have or of currently sold models e Cautions regarding safety such as the Usage Precautions and the Safety Precautions comply with the legal and industrial standards at the time of the making of this operating manual Therefore the described contents may not be up to date When you use a past operating manual refer to the cautions related to safety described in the latest operating manual e The product may contain printing material such as cautions related to safety and printing errors aS a Supplement to the operating ma
16. 157 7 Meter Settings 7 3 5 Setting the CC Index Correction Value Sets the preset CC index Correction value CC Index Correction Value Screen Cancel 1 Touch the CC Index Correction Value button The CC index correction value will be displayed CC Index Correction Preset Editing Digital Screen Value Screen Preset No Preset Selection List Preset Name Target CCT LB Index Correction Value CC Index Correction Value Cancel 158 Setting Screen _ _ 7 Meter Settings Setting Screen e 2 Set the CC index correction value within a range of 40 0G 40 0M gt P19 CC Index Correction Value Screen Cancel OK Button Cancel Button 3 Touch the OK button The number is fixed and returns to the Preset Editing screen To return to the Preset Editing screen without confirming touch the Cancel button Preset Editing Digital Screen Preset No Preset Selection List Preset Name Target CCT LB Index Correction Value CC Index Correction Value The CC index correction value is edited x3 i _ Because the CC index correction value unit is an index 1 of CC index is equivalent to 2 5 CC filter number 159 7 Meter Settings Setting Screen e Dark Calibration Dark calibration is performed whenever power is turned on however when there are sudden changes in temperature while in use it may effect measured v
17. RA 88 3 AS 90 3 ie AG R RB Rg 87 0 86 7 o 81 2 58 9 mo 92 6 R1 87 7 R2 66 6 R3 34 2 m4 99 0 R5 965 5 Memory Recal 1 Memory Recall Mode Display Mode Selection Screen M11 Digital 5 Text B CRI Lighting Filter Memory Recall Mode Lighting Filter Mode Target 5000K CCT 5706K Brand LEE LBi LBi CCi CCir Memory Recall 25MK1 1 8 CT STRAW 1 5G 1 8 PLUS GREEN Camera Filter wo a ans a O Memory Recall Mode WB Corr Mode Target 5000K LBi CCi 25MK t 1 5G BA Step 5 OK GH Step 2 5 Tool Box Screen amp _ Memory Recall Mode Spectrum Mode TEE CCet C0256 x oN 5000K 0 0 380 450 540 620 700 780 nn Memory Memory Recall Mode Camera Filter Mode Target 5000K CCT Brand 5706K WRATTEN 2 LEE LBi 25MK 1 LBcf BIA CCi CCer Recall 1 5G CC0256 Display Mode Icon Part Name Memory Recall Mode Text Icon Memory Recall Mode Spectrum Icon Memory Recall Mode CRI Icon Memory Recall Mode Camera Filter Icon Memory Recall Mode Lighting Filter Icon Memory Recall Mode WB Corr Icon 6 Measurement Tool Tool Box Screen Description Displays user selected 5 items in numeric values gt P33 Displays 3 user selected values and spectrum distribution graph gt P36 Display
18. and select the Ambient Light Mode icon on the next screen Select the measuring mode P22 Measuring Mode Measurement Screen Selection Screen Measurement Screen T 1 125 Fo Measuring Mode F Target 5000K wa e A Target 5000K ten ode CCT CCT Cordless Flash Mode Hix Lux Cord PC Flash Mode CCi Radio Triggering Mode LBi 59 5 Measuring Light Sources Measurement Screen 5 Touch the Target indication Target CCT screen will be displayed P26 Set the color temperature Measurement Screen Target CCT Screen Target CCT Digital FE 2500 10000K Target 5000K CGT 5000K Lux CCi Cancel If you are not using LB index filter and CC index filter values you can omit this step You cannot set the target color temperature using the CRI or Multi Lights Mode 3 _ If necessary you can select a previously created Preset value from Preset Selection in the Tool Box gt P146 Tool Box Screen Preset Selection Screen Tool Box Screen i p Digital Film p Digital Film Preset Selection Digital Preset Selection Digital p Preset Selection Film p Memory Title yp Memory Title Not Selected 4 Memory Clear P Memory Clear Memory Recal Memory Recal py Radio Channel Zone p Radio Channel Zone gt Preset Selection Film Close The selected value is in
19. 20 sec t Language Display the information English White Balance Step Oe BA 5 OK GM 2 5 Unit of luminance Mo Ix 1xs fe fes Ms Product Information Radio System Preference ControlTL Standard a Regulation M5 Reset Customized Items I if To page 2 To page 1 To page 3 Close Button To page 2 115 7 Meter Settings Setting Screen e 1 Touch the Setting icon on the Display Mode screen Setting will be displayed 2 Touch the one step icons A V to display the desired page 3 Touch the desired setting name That setting screen will be displayed When the Close button is touched the display returns to the Display Mode Selection screen 116 7 Meter Settings Setting Screen e 7 1 1 Item List The Setting screen items are as follows Item Name Description Customize Shutter Speed Step Select the shutter speed from 1 step 1 3 step and 1 2 step P120 LB Ste Select the LB index display step from 1MK 1daMK no decimal p point step and 0 1daMK with decimal point step gt P123 Select Kodak WRATTEN 2 LEE or FUJIFILM as the camera filter Camera Filter Brand brand P125 ee Select LEE Rosco Cinegel or Rosco E Colour as the lighting filter Lighting Filter Brand brand P127 Set the step for 1 grid square on the WB Corr screen from the ranges below BA 0 5 100 0MK GM 0 5 20 0 gt
20. Out of Display is displayed Under Displayed if value is lower than measurement range too dark or color temperature value Is too low Over Displayed if value is higher than measurement range too bright or color temperature value is too high Out of Display Displayed if there is no more combination of Filter name and number 15 3 Basic Operation Methods __ Status Bar 1 2 3 4 9 6 7 For this description all icons and menus are displayed Description Sufficient battery life remaining Adequate battery life remaining Have a spare battery ready Replace the battery immediately Displayed when powered by USB Battery Capacity Indicator Displays the number of measured data stored in memory The number in memory is displayed until 99 to the right of the mark Displayed when in Digital Mode Displayed when in Film Mode Displays the preset number when a preset is selected 2 Memory Count 3 Digital Film Mode Preset Selection Temperature Fluctuation Warning When the mark is illuminated the color temperature reference is fluctuating and you may be unable to take accurate measurements Please perform dark calibration Displayed when the Light Selection Ring is selected by the dark calibration position Light Selection Ring Status Indicator r Displayed when the Light Selection Ring has range L selected Displayed when the Light Selection Ring has range H selected
21. P129 M Select the unit from Ix Ix s fe fc s or both when measuring Unit of Illuminance l illuminance P131 White Balance Step Spectrum Y axis Scale Select relative auto or spectral radiant intensity P133 Select the time before the power automatically turns off after last use 5min 10min 20min No Auto Power Off When No Auto AUO FOWE OI Power Off is set the automatic power OFF function is not activated P135 Backlight Brightness eon LCD backlight brightness from dark normal or bright Select the time before the backlight dims after last use to save Auto Dimmer extra power or adjust the visibility under the surrounding light condition 20sec 40sec 60sec No Dimmer P139 i anauade Select the language displayed on the touch panel from English guag Japanese or Chinese P141 Radio System Preference Select from ControlTL Standard Control TL Standard or Not in for C 700R only Use P143 Initialize reset only contents of Customize in Setting to the Reset Customized Items factory default 11 items for C 700 and 12 items for C 700R P145 Preset Editing Edit a preset for film or digital separately gt P146 Perform a dark calibration P160 Models sold in some countries do not display illuminance and exposure in fc fc s due to legal restrictions 117 7 Meter Settings Setting Screen You can set the display contents of 11 items C 700 12 items C 700R
22. Select the channel number that you want to use Radio Channel Zone ControlTL Channel Screen Channel Number 109 6 Measurement Tool Tool Box Screen 4 Touch the Zone icon Set one or more zones A B C The selected zones will be displayed and encircled in blue Radio Channel Zone ControlTL Channel Screen Radio Channel Zone Zone Icon OK Button Cancel Button 5 Touch the OK button Confirm and return to the Measurement screen To return to the Measurement screen without confirming touch the Cancel button 6 Confirm the set channel and zones on the Measurement screen You can see the settings on the button at the lower left hand corner Measurement screen T 1 125 Target 5000K CCT Hix Ra CTL 02 ABC The set content is displayed The ControlTL channel and zones are set 110 6 Measurement Tool Tool Box Screen E Setting Standard Channels Radio Channel Zone Standard Channel Screen STD Tab Channel Number 1 16 Cancel OK Button Cancel Button STD Tab STD Channel Number 17 32 Zone Icon OK Button Cancel Button 111 6 Measurement Tool Tool Box Screen 1 Touch the Radio Channel Zone button in the Tool Box The radio channel zone will be displayed Radio Channel Zone Tool Box Screen ControlTL Channel Screen g Digital Film p Preset Selection Digita
23. Speed 1 250 3 Touch the OK button Confirms the settings and returns to the previous Measurement screen Touch Cancel to return to the previous measurement screen without setting speed The shutter speed is set T 1 250 A 5000K Target 24 4 Setting the Measuring Conditions U nore S Shutter speeds can be selected by the item Shutter Speed Step in page 1 of Setting You can choose 1 step 1 3 step and 1 2 steps P120 Shutter Speed Options 1 Step Factory default gt SteP 1 2 Step o y wwo no o y wo f ao o o wo f ao o ww f ooa o y mo awo p90 o o fo o wo f oo o mo f wo o 120 ao oo J o ono f Co y ee o y S o oo o o ame a e O e ao y ee a Oe po 200 Oo y S ee Special shutter speed setting Q nore o__ _ _ _ _ e Select a shutter speed that will synchronize with your camera and flash system e If you change shutter speed settings the measurement data will be erased 29 4 Setting the Measuring Conditions Setting the Indication and Items in Measurement Screen 4 2 1 Setting Target Color Temperature Use this setting to establish a target color temperature for camera and light source filtration selection The target color temperature is displayed in the upper central part of the Measurement screen 1 Touch the Target indication on the Measurement screen Ex Measuring Screen Text Display
24. Text Icon Spectrum Icon Spectrum Comparison Icon CRI Icon Camera Filter Icon Camera Filter Lighting Filter Icon Multi Lights Icon White Balance Correction Icon Setting Icon 1 8 are the Measurement screen 30 4 Setting the Measuring Conditions Description Displays user selected 5 items in numeric values P33 Displays 3 user selected values and spectrum distribution graph gt P36 Compares the current measurement value and up to 2 memorized values in the spectrum distribution graph gt P38 Displays the selected average CRI Ra or individual CRI R1 R15 numerically Each CRI is displayed in a bar graph gt P43 Displays correction values and camera filter names required to adjust measured source to Target Color temperature gt P45 Displays correction values and light source filter names required to adjust measured source to Target Color temperature gt P47 Displays comparative correction values from multiple measurements P49 Displays the difference between the current measurement value and the target color temperature in a white balance graph gt P53 Displays Setting screen P55 4 Setting the Measuring Conditions 1 Touch the Display Mode icon on the Measurement screen or press Menu Button on the meter The Display Mode Selection screen will be displayed P29 Display modes from No 1 to 8 are for meas
25. The radio waves may cause accidents through misoperation e Do not use the meter inside airplanes The radio waves may cause accidents through misoperation e Stop using the meter when there is electromagnetic interference with other devices The radio waves may cause accidents through misoperation e To comply with local broadcast regulations Sekonic wireless systems sold in the various markets around the world are designed to operate at different frequencies Sekonic meters having a FCC amp IC designation on the back of body are designed for operation in the USA and Canadian market Frequencies Standard System CH1 to 16 344 0MHz CH17 to 32 346 5 to 354 0MHz ControlTL System CH1 to 4 340 0 to 346 0MHz CH5 to 20 341 5 to 351 0MHz Sekonic meters having a CE designation on the back of body are designed for operation in European countries Frequencies Standard System CH1 to 16 433 62MHz CH17 to 32 434 22 to 354 0MHz ControlTL System CH1 to 3 433 42 to 434 42MHz e Both FCC and CE versions of C 700R have built in transmitting antennas that are specifically tuned for their market area When purchasing and or using the meter with a receiver be sure that the meter and receiver are designed to be used in your location and use the same frequency 76 5 Measuring Light Sources Measurement Screen G noT oE A The working distance of the wireless triggering system differs depending on the position
26. X Radio System Preference Yes Button a Reset Customized Items v A Close No Button 2 Touch the Yes button Custom settings are reset After finishing initialization returns to Setting To return to Setting without initializing touch the No button 145 7 Meter Settings Setting Screen e 7 3 Preset Editing Presets are a quick way to introduce adjustments to the C 700 s camera light source filter recommendations You can create and store Presets for different lighting conditions or color effects to use when ever needed The Spectromaster C 700 700R has been calibrated to Sekonic standards However if the indicated compensating values do not yield the desired or expected color reproduction than it will be necessary to modify the filter compensation values In this case if you save the compensation values in memory as a preset number and then take measurements you can display results with the compensated values Also when you use several target color temperatures you can easily set the target color temperature by recalling one of presents in Tool Box even if you do not input a target color temperature every time Depending on the camera used select either Preset Editing Digital or Preset Editing Film Preset Editing Digital Screen Preset Editing Film Screen Preset No Preset No Preset Selection List Preset Selection List mI ge m1 ae Preset Name Preset Name Target C
27. in Customize P1 to 2 of Setting to customize your meter for your preference The current setting for each item is displayed in yellow letters Setting Page 1 Screen Ley Shutter Speed Step tt LB Step Camera Filter Brand a Lighting Filter Brand White Balance Step a Unit of I luminance 1 Touch the Setting icon on the Display Mode screen Setting will be displayed Setting Page 2 Screen Spectrum Y axis Scale t Auto Power Off Back ight Brightness y Auto Dimmer Language a Radio System Preference a Reset Customized Items Yy A Close Item white letters Current Setting Value yellow letters 2 Touch the one step icons A V to display the desired page 3 Touch the desired item The item screen will be displayed When the Close button is touched the display returns to the Display Mode Selection screen 118 7 Meter Settings Setting Screen 7 2 1 Item Specifications The specifications of each Customize item is as follows Item No Setting Name Default 1 Shutter Spree 1 Step 1 3 Step 1 2 Step 1 Step Step 1 1daMK 0 1daMK 1 Camera Filter WRATTEN 2 FUJIFILM WRATTEN 2 Brand LEE Lighting Filter ROSCO ROSCO Unit of Ix Ix s Ix Ix s Spectrum Y axis l Spectral Radiant Intensity Auto Power Off 5min 10min 20min AANG 5min Power Off Backugnt Dark Normal Bright Normal Brightness 0 Auto Dimmer 20sec 40sec 60sec
28. now be made Measuring Button Measurements and display will take longer in light levels below 30Ix The LCD illumination will normally switch off during measurements to avoid influence to measurements 5 The red point shows the correction value from the target color temperature Displays corrected value 2 hi 3 6 O OBA Step 5 0K4 GH Step 2 5 Displays value per one matrix 6 Memorize the measurement results Measurement results can be memorized To record measurements press Memory Button gt P95 The value per matrix can be changed by the item White Balance Step in page 1 of Setting Match the value with your camera P129 54 4 Setting the Measuring Conditions 4 3 9 Displaying Setting Setting Screen Displays the settings The contents can be changed according to usage For more information about how to set and the details of specifications see 7 1 1 Item List gt P117 Setting Screen Page 1 Ley Shutter Speed Step tt LB Step Camera Filter Brand 2 Lighting Filter Brand t White Balance Step a Unit of I luminance Models sold in some countries do not display illuminance and exposure in fc fc s due to legal restrictions In this case Unit of Illuminance is not displayed Setting Screen Page 2 Be Spectrum Y axis Scale y Auto Power Off Back ight Brightness Auto Dimmer Language Be Radio System Preference Me
29. steps 1 through 5 for display areas B C and D Up to 4 light sources can be compared e Touch the A B C or D button to confirm the measured values e Measurements and display will take longer in light levels below 30Ix The LCD illumination will normally switch off during measurements to avoid influence to measurements 51 4 Setting the Measuring Conditions _ T Touch the radio button of the light source to set as the reference Selected CO Not selected Measured values will be displayed in CCT indication regardless of selecting the standard value Correction values LB index against the standard light sources will be displayed in LBis of light sources The CC index shows the deviation from the black body radiation at a measured color temperature For this reason even when the standard light source is set the CC index shows the deviation from the black body radiation not the difference between the selected standard and the other light sources Multi Lights Screen 558 s Standard Selection Radio Button 1 4 Selected Status 6277K 20MK 1 5G Corrected Value Display To clear all of the measurement results and start a measurement comparison again touch the Clear button The Multi Lights Clear Confirmation screen will be displayed Multi Lights Screen Clear Confirmation Screen 5587K Remove the measured value Are you sure Yes Button Clear Button Touch the Yes button
30. such as fluorescent lights or special lighting could cause the meter to take cordless flash measurements in rare cases In these situations use 5 4 Measurement in Cord PC Flash Mode P68 e If the Light Receptor detects a sudden bright change in lighting intensity the meter may mistakenly take a measurement To avoid this take 5 4 Measurement in Cord PC Flash Mode P68 e Because the light radiated from a flash bulb gradually builds the meter will not detect the light when used in Radio Triggering Flash Mode Be sure to take 5 4 Measurement in Cord PC Flash Mode P68 e When using Flash Cordless Mode the LCD screen backlight dims during measurement and the LCD backlight is illuminated for only 3 seconds after measurement To cancel standby mode touch the screen or press the Memory Button 83 5 Measuring Light Sources Measurement Screen 5 6 Contrast Function in Ambient Light Mode only In all item except LB CC filter name modes when you touch the Delta icon EER the Delta icon changes to i While this mode the difference between standard value N and currently being measured value is displayed as long S as the Measuring Button is pressed o The reference value is the measurement value when the Delta icon is pressed When the Measuring Button is released the standard value is displayed as the last measurement The graphs in Spectrum CRI and White Balance Correc
31. to make 3 p Radio Channe Zone o selection OK Button Cancel Button 3 Touch the OK button The meter will display the display mode viewed when the light source was memorized To return to the Measurement screen without confirming touch the Cancel button 4 Confirm the memory contents Display Mode at the time when memorized appears In Memory Recall Mode the background color becomes green Ex Memory Recall Mode Spectrum Screen SO Oo N M C Spectrum Distribution Graph Enlarged Display Target 5000K C0256 a Close Button 99 6 Measurement Tool Tool Box Screen C noT eE e Only the current reading can be memorized in the Spectrum Comparison Mode If the Spectrum Comparison screen is displayed when the memory button is pressed the stored data will be displayed on the Spectrum display screen e In Memory Recall Mode measurement cannot be made 5 Touch the Close button Returns to the Measurement screen 100 6 Measurement Tool Changing the Display Mode of Memory Recall Touch the Display Mode icon in Memory Recall Mode and available Display Modes of memory recall appear Touch each icon to display a specified display mode Memory Recall Mode Memory Recall Mode Text Mode z 5 5000K Target CCT 5706K Lux 929Lx CCi 1 5G o do WwW Memory Recall Mode CRI Mode Ra 89 3 R 82 4 R2 34 3 R3 84 5
32. value in the compensation LB Lighting filter name The filter manufacturer is selected in the o BEE Average CRI Displays the average value of ORIRTIORS Models sold in some countries do not display illuminance and exposure in fc fc s due to legal restrictions 28 4 Setting the Measuring Conditions Touching an icon on the Display Mode Selection screen displays lighting information in different ways to suit your needs Pressing the Menu Button returns the screen to the Display Mode Selection m M 1 Digital M1 Digital wm M11 Digital A Target 5000K CCT Lux CCi LBi Ra m M1 Digital wm M11 Digital wm 1 Digital Target CCT A eS Spectrum fa N D Camera Filter Ce 1 Digital Target 5000K LBi 21K Mi coy 1G CCi 29 Target 5000K A CCT m m CCT Spectrum Comp cer Lighting Filter Cl 1 Digital Target 5000K Setting CCT Brand LBi LBit CCi CCit Current Measurement 5587K Auv 0 0129 LED NO 4 05 4331K Auv 0 0093 LED NO 4 04 3079K Auv 0 0007 5587K LEE 21MK 1 8 CT STRAW 1 7G 1 8 PLUS GREEN Ce 1 Digital Target 5000K 5587K Brand WRATTEN 2 LEE LBi 21MK LBet 81A CCi 1 7G CC0256 P Cl 1 Digital 4 Shutter Speed Step Le LB Step Camera Filter Brand Lighting Filter Brand By White Balance Step Unit of I luminance Display Mode Icons List Display Mode Name
33. will be displayed Setting Screen LB Step Screen patentee at tte 1MK Be Shutter Speed Step y LB Step IdaMK a Camera Filter Brand 0 1daMK7 a Lighting Filter Brand White Balance Step Unit of I luminance 123 7 Meter Settings Setting Screen e 2 Touch the desired LB step value to use Select the LB Step value 1MK IdaMK 0 1daMK7 LB Step Screen 1MK7 1daMK 0 IdaMK Measurement Screen Display Example LBi 6QMK 3 Touch the OK button _ gt LBi 6daMK7 Confirms the settings and returns to Setting To return to Setting without confirming touch the Cancel button Setting Screen Shutter Speed Step y LB Step Camera Filter Brand a Lighting Filter Brand White Balance Step Unit of luminance The LB step is set The set content is displayed The selected value will be displayed encircled in blue OK Button Cancel Button U Note e 1MK is equivalent to 1Mired e The unit MK is now used based on the International System of Units SI instead of traditional unit Mired The latest unit is adopted to the Spectromaster C 700 700R 124 7 Meter Settings Setting Screen e 7 2 4 Selecting the Camera Filter Brand Select WRATTEN 2 LEE Kodak WRATTEN 2 or Lee or FUJIFILM FUJIFILM as the camera filter brand Camera Filter Brand Screen WRATT
34. 2 2011 09 EN301 489 3 V1 6 1 2013 08 EN62479 2010 F SAFETY EN 60950 1 2006 A11 2009 A1 2010 A12 2011 A2 2013 EMC EMS EN55024 2010 EMI EN55022 2010 WEEE RoHS REACH E North CC FCC Part15 SubpartB ClassB emacs US Wireless FCC Part15 SubpartC IC EMC ICES 003 Canada RSS 210 Issue8 Japan Environmental _ Containers and Packaging Recycling Law 187 10 Optional Accessories __ 1 0 Optional Accessories E Synchro Cord A convenient five meter 16 4 feet long cord with three plugs allowing you to connect and synchronize between a color meter flash unit and camera so there is no need to plug or unplug the cord during a shooting Also one terminal of the sync cord has a locking mechanism to ensure connection when used with a color meter S A 0 188 11 Troubleshooting _ 11 Troubleshooting The following cases may not suggest failures Please check again before requesting repair When the meter does not function normally after checking the following it may be damaged Remove the battery and ask the retailer or us to repair it Check item Measure It does not turn on Are you pressing and holding the Press and hold the Power Button It does not display Power Button for one or more for one or more seconds seconds Are of the batteries inserted Check the signs P4 properly Is there enough battery Replace the battery gt P9 Are the batter
35. 24 14 Oizumi Gakuen Cho Nerima Ku Tokyo 178 8686 Japan Tel 81 3 3978 2335 Fax 81 3 3978 5229 http www sekonic com JT1297631 JANUARY 2015
36. 8 9 DEL ABC DEF abc GHI JKL MNO jkl PQRS TUV WXYZ Cancel Cancel Cancel do AY 7 Numbers 7 Upper Case Letters 7 Lower Case Letters nee Method of Characters and Numbers Description ry 1 Ala Shifts between numbers upper case letters lower case letters 0 9 ABC Value displayed on screen when key touched abc hyphen Repeated touching of the same button for alphabet ABC abc will change period the alphabet character in order OCSE 20 3 Basic Operation Methods __ 3 2 4 Locking and Unlocking the Screen You can lock the screen to prevent misoperation When the screen is locked touch operation is disabled However the Memory Button Measuring Button and Power Button are still operational The screen will stay locked even when power is turned OFF and ON Power Button Memory Button Measuring Button To Lock When the Menu Button is pressed and held the screen is locked and the Locked icon is displayed in the upper right corner of the LCD While the screen is locked icons on the LCD cannot be operated When icons are touched in locked mode the Locked icon will be displayed for approximately 1 second The operation of menu functions by pressing the Menu Button is also disabled This lock function can be set in the Measuring screens only Menu Button O To Unlock When the Menu Button is pressed and hel
37. CT Target CCT LB Index Correction Value LB Index Correction Value CC Index Correction Value CC Index Correction Value Up to 19 presets can be registered for each digital and film 146 7 Meter Settings Setting Screen e 1 Touch the item Preset Editing Digital or Present Editing Film button on page 3 of Setting The Preset Editing screen of Setting will be displayed Preset Editing Setting Screen Digital Screen Preset No Me Preset Editing Digital Preset Selection List My Preset Editing Film Hide Preset Name Me Dark Calibration Target CCT a Product Information LB Index Correction Value Me Regulation CC Index Correction Value 2 Touch the Preset No button The preset number is displayed Preset Editing Digital Screen Preset No Screen Preset No Preset Selection List Preset Name Target CCT Blue bar f indicates LB Index Correction Value the number CC Index Correction Value selected Cancel 147 7 Meter Settings Setting Screen e 3 Select the desired present number 1 19 to edit Preset No Screen OK Button Cancel Cancel Button Cancel 4 Touch the OK button The number is fixed and returns to the Preset Editing screen The desired preset number to edit is displayed To return to the Preset Editing screen without confirming touch the Cancel button Preset Editing Digital Scr
38. EN 2 LEE Default FUJIFILM Cancel 1 Touch the item Camera Filter Brand button on page 1 of Setting The camera filter brand will be displayed Setting Screen Camera Filter Brand Screen promt WRATTEN 2 LEE Be Shutter Speed Step LB Step FUJIFILM a Camera Filter Brand a Lighting Filter Brand a hite Balance Step a Unit of I luminance 125 7 Meter Settings Setting Screen e 2 Touch the desired camera filter brand to use Select the filter brand of the camera used Camera Filter Brand Screen WRATTEN 2 LEE WRATTEN 2 LEE FUJIFILM FUJIFILM Cancel Cancel The selected brand will be displayed encircled in blue OK Button Cancel Button 3 Touch the OK button Confirms the settings and returns to Setting To return to Setting without confirming touch the Cancel button Setting Screen fp Shutter Speed Step y LB Step Camera Filter Brand i N A The set content is displayed Lighting Filter Brand White Balance Step a Unit of I luminance The camera filter brand is set 126 7 Meter Settings Setting Screen e 7 2 5 Selecting the Lighting Filter Brand select LEE ROSCO CINEGEL or ROSCO E COLOUR as the lighting filter brand Lighting Filter Brand Screen LEE Default ROSCO CINEGEL ROSCO E COLOUR Cancel 1 Touch the Lighting Filter Brand button on page 1 of Setting The lighting filter br
39. Film gp Memory Title Memory Clear Se Blue bar Memory Recal indicates the g Radio Channel Zone item selected A Preset value must be created and saved in the Preset Editing function under the Setting Mode icon before it can be used Preset Selection buttons will be grayed out until settings are created 2 Select desired preset no 1 19 Touch Up Down buttons or move slide to position the desired Preset under the blue bar Preset Selection Screen Not Selected L T z J OK Button cancel Cancel Button Be sure to set Preset Selection to Not Selected when no correction is desired 93 6 Measurement Tool Tool Box Screen 3 Touch the OK button Confirm and return to the Measurement screen To return to the Measurement screen without confirming touch the Cancel button The selected status will be displayed on the status bar The selected preset no is displayed The preset is set G noric ___________ _ When selected the Preset Color Temperature is used by the meter in place of the Target Color Temperature that was selected from the Measuring screen 94 6 Measurement Tool Tool Box Screen Using the Memory Function 6 3 1 Naming Memorized Measurement Values The memory function enables storing light source data for single sources and groups of sources for recall at any time You can create special titles for memorized values to
40. Ix 0 46FC 18 600FC in limited version only 11x to 200 000Ix 0 1fc to 18 600fc in limited version only Range L 20Ix s 640Ix s f 2 8 to f 16 Range H 640Ix s 20 500Ix f 16 to f 90 183 Accuracy e Iluminance e Color temperature Repeatability 20 e Illuminance 9 Appendix _ 5 1digit of indicated value 3000Ix 7 5 1digit Complies with JIS C1609 1 2006 general A class illuminometer 4MK Light source A 8001x 1 1digit Light source A 30 200 00Ix 5 1digit Light source A 1 30Ix e Color e Light source A 500 100 000Ix 2MK temperature Light source A 100 5001x 4MK e Light source A 30 1001x 8MK e Light source A 5 301x 17MK Spectral response characteristics o f1 Oblique incident light characteristics o f2 Temperature characteristics e iluminance e Color temperature Humidity characteristics e lluminance e Color temperature Display range e Correlated color e Digital temperature e Photographic e Film color temperature e Target color temperature settings e LB Index e 1MK step e 1daMK step e 0 1daMK step e CC index e 80G 80M 9 or less Complies with JIS C1609 1 2006 general A class illuminometer 6 or less Complies with JIS C1609 1 2006 general A class illuminometer 5 of indicated value Complies with JIS C1609 1 2006 general A class illuminometer 12MK Light source A 10001x 3 of indicated val
41. Meter Settings Setting Screen e When the Following Screen is Displayed Dark Calibration Position Confirmation Screen Dark Calibration failure Screen The Light Selection Ring is set to Range H ay or Range L i and dark calibration could not be performed Set the Light Selection Ring to the dark calibration position and perform dark calibration Dark calibration was performed but it could not be completed normally Set the Light Selection Ring to the dark calibration position again and perform dark calibration one more time 162 7 Meter Settings Setting Screen e Product Information Display The Product Information screen displays detailed information not displayed in the Measurement screen Product Information Screen Mode Name Serial Number F W Version User Information Radio Regulation The screen contents differs depending on model Item Name Description gy Model Name Displays the model number of the meter C 700 or C 700R Serial Number Displays the serial number of the meter Displays the firmware version 4 User Displays the user information You can input desired characters in the Information Hardware Setting as user information P166 Radio l l oe l Regulation Displays the radio regulations used in Radio Triggering Flash Mode 163 7 Meter Settings Setting Screen e 1 Touch
42. No Dimmer 20sec Selected by 11 Language English Japanese Chinese po deai Radio System ControlTL ControlTL Preference Controll SANEA Standard tn aE Standard neset When you touch the OK button the Setting contents will 13 Customized f faul items be reset to factory default C NOTE _ _ _ ___ e 1MK is equivalent to 1Mired e The unit MK is now used based on the International System of Units SI instead of traditional unit Mired The latest unit is adopted to the Spectromaster C 700 700R of 119 7 Meter Settings Setting Screen 7 2 2 Selecting the Shutter Speed Step Select the shutter speed from 1 step 1 3 step and 1 2 step Shutter Speed Step Screen 1 step Default 1 3 step 1 2 step Cancel Selectable Shutter Speeds in seconds 1 Step 1 1 2 1 4 1 8 1 15 1 30 1 60 1 125 1 250 1 500 1 75 1 80 1 90 1 100 Default 1 200 1 400 1 0 8 0 6 0 5 0 4 0 3 1 4 1 5 1 6 1 8 1 10 1 13 1 15 1 20 1 25 1 30 1 3 Step 1 40 1 50 1 60 1 80 1 100 1 125 1 160 1 200 1 250 1 320 1 400 1 500 1 75 1 80 1 90 1 100 1 200 1 400 1 2 Ste 1 0 7 1 2 1 3 1 4 1 6 1 8 1 10 1 15 1 20 1 30 1 45 1 60 1 90 1 125 p 1 180 1 250 1 350 1 500 1 75 1 80 1 90 1 100 1 200 1 400 120 7 Meter Settings Setting Screen e 1 Touch the item Shutter Speed Step button on page 1 of Setting The s
43. Reset Customized Items y A Close Setting Screen Page 3 radiItT a Pl l a Preset Editing Digital a Preset Editing Film Me Dark Calibration a Product Information a Regulation Indicated only for C 700R model G oTe Pressing the Menu Button will terminate the settings and return to the Display Mode Selection screen 55 Menu Button O 4 Setting the Measuring Conditions 1 Touch the Setting icon on the Display Mode Selection screen The Setting screen will be displayed Display Mode i Selection Screen Setting Screen Page 1 Be Shutter Speed Step Spectrum Text Spectrum Comp t LB Step a Camera Filter Brand amp Lighting Filter Brand Camera Lighting White Balance Ste Filter Filter Mo k Unit of I luminance ppm iR Multi Lights WB Corr Setting 2 Setting shows items in white letters and setting contents in yellow letters Touch each item to change the setting Setting Screen Setting Screen Setting Screen Page 1 Page 2 Page 3 Shutter Speed Step a Spectrum Y axis Scale o Preset Editing Digital tt LB Step Auto Power Off a Preset Editing Film a Camera Filter Brand Backlight Brightness a Lighting Filter Brand t Auto Dimmer s Dark Calibration a White Balance Step Le Language lay o Product Information Unit of I luminance ft Radio System Preference Mx Regulation a Reset Customiz
44. SEKONIC Spectrometer for Photo Video Cine SPECTROMASTER C 700 C 700R Operating Manual Please read the operating manual carefully to fully understand the features of this product before use and keep it for future use Keep the operating manual in a safe place Congratulations on your purchase of a Sekonic SPECTROMASTER C 700 C 700R Please read the operating manual carefully to properly utilize the many features and benefits of this precision instrument The Sekonic SPECTROMASTER C 700 C 700R is the first spectrometer that measures every light source LED HMI Flourescent and the natural light spectrum PLUS wireless flash C 700R only In addition with its CMOS linear image sensor the SPECTROMASTER C 700 C 700R makes it possible to create output wavelength in 1 nm increments capture spikes in light source output especially fluorescent and LED lighting and provide unmatched color measurement accuracy In addition the C 700 C 7000 Series Utility included as an accessory of this product can be used to save data display measurement values and graphs and perform settings when the meter is connected by USB to computers or tablets Terminology and trademarks e Windows is a registered trademark of Microsoft Corporation in the USA and or other jurisdictions e The official name of Windows is Microsoft Windows Operating System e Macintosh and MacOS are trademarks of Apple Computer Inc registered in the USA and or othe
45. Screen and Operation 3 2 2 Icon Operation 3 2 3 Input of Numbers Characters 3 2 4 Locking and Unlocking the Screen 4 Setting the Measuring Conditions WZE Selecting the Measuring Mode 4 1 1 Matching Measuring Mode with Light Sources 4 1 2 Selecting the Shutter Speed Flash Modes Only WP Setting the Indication and Items in Measurement Screen 4 2 1 Setting Target Color Temperature 4 2 2 Customizing Measuring Displays Vil 12 12 14 14 18 19 21 22 22 22 24 26 26 28 WE Selecting the Display Mode 29 4 3 1 Displaying in Text Text Mode 33 4 3 2 Displaying in Spectrum Graph Spectrum Mode 36 4 3 3 Displaying in Spectrum Comparison Spectrum Comp Mode 38 4 3 4 Displaying in Color Rendering Index CRI Mode 43 4 3 5 Displaying in Camera Filter Camera Filter Mode 45 4 3 6 Displaying in Lighting Filter Lighting Filter Mode 47 4 3 7 Displaying to Compare Light Sources Multi Lights Mode 49 4 3 8 Displaying in White Balance Correction Graph WB Corr Mode 53 4 3 9 Displaying Setting Setting Screen 55 5 Measuring Light Sources Measurement Screen of EZ Measurement Method 57 5 1 1 Balancing Color Temperatures of Light Sources 57 WEP Measurement in Ambient Light Mode 58 WW Measurement in Cordless Flash Mode 62 WEL Measurement in Cord PC Flash Mode 68 WEE Measurement in Radio Triggering Flash Mode C 700R Only 75 5 5 1 Measurement Method 77 5 5 2 Setting the Radio Channel 78 EZ Contrast Function in Ambient Light Mode on
46. Target Color Temperature Input the target color temperature for preset Reference Color Temperature Screen Cancel 1 Touch the Target CCT button The Target CCT screen will be displayed Preset Editing Digital Screen Target CCT Screen Preset No Preset Selection List Preset Name Target CCT LB Index Correction Value CC Index Correction Value Cancel 153 7 Meter Settings Setting Screen e 2 Enter the value of the target color temperature P19 The units place is fixed as 0 Target CCT Screen DEL Cancel OK Button Cancel Button 3 Touch the OK button The number is fixed and returns to the Preset Editing screen To return to the Preset Editing screen without confirming touch the Cancel button Preset Editing Digital Screen Preset No Preset Selection List Preset Name Target CCT LB Index Correction Value CC Index Correction Value The reference target color temperature is edited 154 7 Meter Settings Setting Screen e C nore S Digital Mode Set the meter to the same color temperature that was selected in your camera Please note that many digital cameras reproduce color better at certain color temperature settings If your work requires optimum color reproduction and high color fidelity select the camera manufacturers recommended color temperature for best color reproduction Please refer to your digital camer
47. Target Color temperature You can select filter brand in advance in Setting Kodak WRATTEN 2 LEE or FUJIFILM Camera Filter Screen Target Indication Measuring Mode Icon Dioer isda licen Measurement Value Camera Filter Display Color Temperature CCT 998 K Filter Brand Brand WRATTEN 2 LEE LB Index LBi 21MK1 Filter Name LBet 81A CC Index CCI 1 7G Filter Name CCef C0256 J 1 Touch the Camera Filter icon on the Display Mode screen The Camera Filter screen will be displayed P29 2 Touch the Measuring Mode icon The Measuring Mode Selection screen will be displayed Select the desired measuring mode to use P22 3 Touch the Target indication Target CCT Input screen will be displayed P26 Set the desired color temperature number 45 4 Setting the Measuring Conditions 4 Press the Measuring Button to measure Light Selection Ring Turn the Light Selection Ring to select the range When measuring ambient light make sure to select Range L lo When measuring flash units select Range L a or Range H fo depending on the brightness of of the flash gt P86 gt P88 Measurements can now be made Measuring Button Measurements and display will take longer in light levels below 30Ix The LCD illumination will normally switch off during measurements to avoid influence to measurements 5 Memorize the measurement results Measurem
48. a s operating manual e You can set the color temperature from 2 500K to 10 000K When you frequently use several target color temperatures use preset for convenience Film Mode Set the target color temperature of the type of film you are using Daylight Type 5 500K Tungsten Type A 3 400K Tungsten Type B 3 200K You can set the target color temperature from 2 500K to 10 000K 155 7 Meter Settings 7 3 4 Setting the LB Index Correction Value Sets the preset LB index Correction value LB Index Correction Value Screen Cancel 1 Touch the LB Index Correction Value button The LB index correction value will be displayed LB Index Correction Preset Editing Digital Screen Value Screen Preset No Preset Selection List Preset Name Target CCT LB Index Correction Value CC Index Correction Value 156 Setting Screen __ 7 Meter Settings Setting Screen e 2 Set the correction value within a range of 100MK P19 LB Index Correction Value Screen DEL OK Button Cancel Button 3 Touch the OK button The number is fixed and returns to the Preset Editing screen To return to the Preset Editing screen without confirming touch the Cancel button Preset Editing Digital Screen Preset No Preset Selection List MI Preset Name Target CCT LB Index Correction Value CC Index Correction Value The LB index correction value is edited
49. alues In this case perform dark calibration manually Dark Calibration Confirmation Screen Light Selection Ring Status Indicator Chart Content If either of icons appears set the Light Selection Ring to the dark calibration position This icon is the dark calibration position Perform dark calibration after making sure it is set to this position 1 Touch the item Dark Calibration button on page 3 of Setting Perform Dark Calibration will be displayed Dark Calibration Confirmation Screen Setting Screen Mg Preset Editing Digital Mx Preset Editing Film Me Dark Calibration a Product Information Mx Regulation 160 7 Meter Settings Setting Screen e 2 Turn the Light Selection Ring to set to the dark calibration position E The status bar will display the dark calibration Icon Status Bar Light Selection Ring 3 Touch the Yes button Dark calibration in progress Please wait and the status bar will appear while calibrating To return to Setting without performing dark calibration touch the No button Dark Calibration Dark Calibration Confirmation Screen Process Screen Yes Button No Button S39 ______ _ While the message Dark calibration in progress Please wait or the progress bar is displayed do not turn the power off Otherwise the meter may be damaged The dark calibration is completed 161 7
50. and direction of the radio receiver For the best conditions follow these steps when placing the meter and the radio receiver 1 Make sure nothing is between the meter and the radio receiver 2 Place the radio receiver away from any large metallic objects concrete and objects with large amounts of water people plants etc 3 Secure the radio receiver with tape or a tripod When placing on the flash pack make sure the antenna of the radio receiver is higher than the flash pack Prevent the radio receiver antenna from directly contacting metallic material 4 Depending on the shooting location there may be times when the radio receiver receives no signal This may be due to radio reflection from nearby objects or other causes Under normal conditions moving the radio receiver a few centimeters may improve reception Do not place the radio receiver behind things that absorb or easily intercept radio waves such as concrete metal or hills 5 Use within approximately 30m 100 feet while following the above conditions 5 5 1 Measurement Method Selecting Radio Channels ControlTL channels and Standard channels are the radio channels of the meter that can be used for measurements ControlTL Channels The C 700R is designed for use with PocketWizard radios There are 20 channels for FCC amp IC and 3 for CE You can set 3 zones A B and C for each channel When used with ControlTL radios the C 700R cannot control flash p
51. and will be displayed Setting Screen Lighting Filter Brand Screen LEE Be Shutter Speed Step a ROSCO CINEGEL a Camera Filter Brand Lighting Filter Brand ius ad a White Balance Step a Unit of I luminance Cancel 127 7 Meter Settings Setting Screen e 2 Touch the desired filter brand to use Select the filter brand of the lighting used Lighting Filter Brand Screen LEE LEE ROSCO CINEGEL ROSCO CINEGEL The selected brand will be ROSCO E COLOUR ROSCO E COLOUR r displayed encircled in blue Cancel Cancel OK Button Cancel Button 3 Touch the OK button Confirms the settings and returns to Setting To return to Setting without confirming touch the Cancel button Setting Screen Shutter Speed Step y LB Step Camera Filter Brand ighting Fi Brand i i Lighting Filter The set content is displayed a Hh ite Balance Step a Unit of I luminance The lighting filter brand is set 128 7 Meter Settings Setting Screen e 7 2 6 Selecting the White Balance Step Select the unit per step displayed per grid cell on the WB Corr Mode measurement screen from a range of BA 0 5 to 100 0MK GM 0 5 to 20 0 White Balance Step Screen BA Step Default 1 Touch the item White Balance Step button on page 1 of Setting The white balance step will be displayed Setting Screen White Balance Step Screen BA Step Be Shutter Sp
52. annel zone to use P108 When you touch the CTL tab or the STD tab the screen will change Radio Channel Zone Measurement Screen ControlTL Channel Screen T 1 125 B Radio Channe Zone a CT tab Target 5000K CCT A Hix B Zone Button Channel Number 1 20 Cancel Radio Channel Zone Standard Channel Screen Radio Channe Zone STD Tab Channel Number 1 16 Cancel STD Tab Zone Button Channel Number 7 32 Cancel 81 5 Measuring Light Sources Measurement Screen C Nore If necessary you can select a previously created Preset value from Preset Selection in the Tool Box gt P146 Tool Box Screen g Digital Film Preset Selection Digital p Preset Selection Film zx Not Selected 5 Memory Title Oe OY _ _ _ ESAS AO Memory Recal g Radio Channel Zone Preset Selection Screen yy Digital Film Tool Box Screen p Preset Selection Digital p Preset Selection Film Memory Title Memory Clear Memory Recal p Radio Channel Zone Cancel The selected value is indicated by the blue background If no presets have been created the Preset Selection will be grayed out and touching the button will not display the Preset Selection Display You can omit this step if unnecessary 8 Confirm the light measuring range When you return to the Measurement screen select Range L fis depending on
53. ape To return to the Spectrum Comp screen touch the Magnifying Glass icon on the enlarged spectrum comparison graph Spectrum Comp Screen Spectrum Comparison Graph Enlarged Display Target 5000K Current Measurement CCT 5587K Auv 0 0129 LED NO 4 05 CCT 4331K Auv 0 0093 LED NO 4 04 CCT 3079K Auv 0 0007 When the enlarged graph is displayed measurement cannot be performed 41 4 Setting the Measuring Conditions C Note The maximum display value of the Y axis can be selected by the item Spectrum Y axis Scale icon in page 2 of Setting P133 12 Memorize the measurement results Measurement results can be memorized To record measurements press Memory Button P95 42 4 Setting the Measuring Conditions _ 4 3 4 Displaying in Color Rendering Index CRI Mode Displays the selected average CRI Ra or individual CRI R1 R15 numerically Each CRI isdisplayed in a bar graph CRI Screen Display Mode Icon CRI Display Measurement Value Display Area Measuring Mode Icon Display Item Indication Graph Display Area Displays CRI in horizontal bar graph 1 Touch the CRI icon on the Display Mode screen The CRI screen will be displayed P29 2 Touch the Measuring Mode icon The Measuring Mode Selection screen will be displayed Select the desired measuring mode to use P22 Light Selection Ring 3 Press the Measurin
54. ary because the intensity of the light is already decreased E Kodak WRATTEN 2 LEE Filter Camera Filter Amber Type Blue Type Exposure Exposure Increase LB Index Increase Increment MK Increment EV LB Index MK Filter Number Filter Number 0 lt NO N w oO O O W D gt N Co _ oe oO O o1 Magenta Type Green Type Exposure Exposure CC index Filter Number INS SK CC index Filter Number meen Increment Increment EV EV CC025M E FUJIFILM Filter Camera Filter Amber Type LB Index ie Filter Number Magenta Type CC index Filter Number Exposure Increase Increment Exposure Increase Increment EV Blue Type LB Index Filter Number Green Type CC index eo cem Filter Number 1 179 9 Appendix __ Exposure Increase Increment Exposure Increase Increment EV 9 Appendix _ E LEE Lighting Filter LB index MK Filter No Filter Name CCT K Conversion CC index Filter No Filter Name CC Filter Equivalent Displayed in C 700 C 700R dw oS 180 9 Appendix _ E ROSCO CINEGEL Lighting Filter LB index MK Filter No Filter Name CCT K Conversion 0x Om ale gt 4 Filter No Filter Name CC Filter Equivalent Displayed in C 700 C 700R dw 3 oj 181 9 Appendix _ E ROSCO E COLOUR Lig
55. at the neck strap does not come loose when carrying the product as the meter may be damaged when dropped e This neck strap is made of polyester fiber Please refrain from using the product if synthetic fibers cause your skin to become irritated inflamed or itchy in order to prevent worsening your symptoms 2 Before Use 22 Installing the Batteries 1 Prepare two AA batteries 2 Slide the Battery Cover Latch in the direction of the arrow and remove the Battery Cover 3 Insert the batteries according to the and symbols in the Battery Compartment As shown in the diagram to the right please note both positive sides of the batteries are facing in the same direction 4 While lining up the two tabs on the Battery Cover press the Battery Cover back into place from above Battery Cover Battery Cover Latch Tabs Battery Compartment Do not place batteries in open flames attempt to short disassemble apply heat to or recharge them except rechargeable batteries They may burst and cause fires serious injury or damage to the environment A CAUTION e Please insert the batteries minus side first When removing the batteries remove them plus side first e Do not use batteries with any other rating than the one specified Also do not mix old and new batteries e f the meter will not be used for an extended period of time it is recommended to remove the batteries to avo
56. d again the screen is unlocked Locked Screen Unlocked Screen Target 5000K CCT 6708K 0 0028 70 2 Target 5000K CCT 6708K 0 0028 70 2 Unlocked Icon Locked Icon 21 4 Setting the Measuring Conditions AA Selecting the Measuring Mode 4 1 1 Matching Measuring Mode with Light Sources Select the Measuring Mode to use Lk3 __ _ If you change measuring mode settings the measurement data will be erased Measuring Mode Selection Screen Measuring Mode 1 Ambient Mode Cordless Flash Mode Cord PC Flash Mode A W N Radio Triggering Mode Indicated only for C 700R model No Measuring Mode Icon Description Measures continuous light such as sunlight tungsten a i B fluorescent and LED lights P58 Detects flash color temperature without meter flash connection after Measuring Button pressed to arm Cordless Flash Mode meter for 90 seconds and flash fired separately Measure using a flash during the wait time P62 Detects flash color temperature with PC synchro Cord PC Flash Mode B cord meter flash connection gt P68 Radio Triggering Flash Detects flash color temperature without meter flash Mode connection after radio transmitted signal is received only for C 700R model by radio receiver connected flash P75 22 4 Setting the Measuring Conditions 1 Touch the Measuring Mode icon in the upper left corner of the scre
57. d on the status bar w11 Film Jp p a The selected Film is displayed The camera type is set e If Digital is selected settings based on human eye characteristics correlated color temperature are displayed If Film is selected settings based on film s characteristics photographic color temperature are displayed e Please note that color reproduction may be inaccurate if Digital is selected when using a film camera or vice versa 91 6 Measurement Tool Tool Box Screen _ 6 2 Setting Preset Contents Preset Selection Screen Presets are a quick way to introduce adjustments to the C 700 s camera light source filter recommendations You can create and store Presets for different lighting conditions or color effects to use when ever needed P146 Also when you use several target color temperatures setting them in Edit a Preset beforehand makes it easier to change target color temperatures by recalling one of presents in Tool Box even if you do not input a target color temperature every time Preset Selection Screen There are 19 Presets that can be displayed and used Not Selected es S I A v A Cancel 92 6 Measurement Tool Tool Box Screen 1 Touch the Preset Selection button in the Tool Box The Preset Selection screen will be displayed Tool Box Screen Preset Selection Screen p Digital Film p Preset Selection Digital p Preset Selection
58. dicated by the blue background If no presets have been created the Preset Selection will be grayed out and touching the button will not display the Preset Selection Display You can omit this step if unnecessary 60 5 Measuring Light Sources Measurement Screen 6 Confirm the light measuring range Light Selection Rin When you return to the Measurement screen make g 90 sure to select Range L lo T Press the Measuring Button Measurement will be taken and the light source values will be displayed While the button is held the meter measures continuously When the button is released the measurements will stop and the light source value at the time of Measuring Button release will be displayed e Over or Under will be displayed if the light source illumination is too bright or not bright enough or if the color temperature is out of the measurement range when the Measuring Button is pressed In this case adjust the brightness or color temperature of light source e Measurements and display will take longer in light levels below 30Ix The LCD illumination will normally switch off during measurements to avoid influence to measurements Measurement in Ambient Light Mode is complete 61 5 Measuring Light Sources Measurement Screen Measurement in Cordless Flash Mode Cordless Flash Mode is preferable when the flash to subject distance is too far to use a sync co
59. ect the measuring mode P22 Measuring Mode Measurement Screen 3 Selection Screen Measurement Screen T 1 125 Fy Measuring Mode F eu Target 5000K Target 5000K Ambient Mode CCT CCT Cordless Flash Mode Lux Hix Cord PC Flash Mode CCi Radio Triggering Mode LBi Ra ya 5 Touch the Target indication Target CCT screen will be displayed P26 Set the color temperature Measurement Screen Target CCT Screen T 1 125 Target CCT Digital FE 2500 10000K Target 5000K CCT 5000K Hix Cancel 19 5 Measuring Light Sources Measurement Screen If you are not using LB index filter and CC index filter values you can omit this step You cannot set the target color temperature using the CRI or Multi Lights Mode 6 Touch the T Shutter Speed indication on the Measurement screen Set the shutter speed used for measurements P24 Match the blue background with the desired shutter speed Measurement Screen Shutter Speed Display Screen mae T 1 125 Target 5000K Ea Fp Target 5000K COT Hix Shutter Speed Screen Shutter Speed The selected value is indicated by the blue background OK Button cance Cancel Button E noric E mmaa Select a shutter speed that will synchronize with your camera and flash system 80 5 Measuring Light Sources Measurement Screen T Touch the Radio Channel Zone button Set the radio ch
60. ed Items v A Close To page 2 To page 3 To page 1 To page 2 Close Button When the Close button is touched the display returns to the Display Mode Selection screen For more information about how to set and the details of specifications see 7 1 1 Item List P117 56 5 Measuring Light Sources Measurement Screen _ 5 Measuring Light Sources Measurement Screen 5A Measurement Method 5 1 1 Balancing Color Temperatures of Light Sources When multiple light sources are being used SETTA the color temperature of each light source must I be measured separately If light sources with different color temperatures are used together in the same image inconsistent color will be 2 present in the shadows and highlights Take a measurement by facing the Light Receptor towards the light source to ty correctly measure the color temperature of the light source Ze Light Receptor P re SS Ginx e It is always important to get the true color of the main light source Then any influence from light reflected off of colored surfaces onto the subject will look as they do when observed by eye e Because it may affect the precision of the measurements be careful not to damage or dirty the white surface of the Light Receptor If the Light Receptor becomes dirty wipe it with a dry and soft cloth Never use organic solvents such as thinner or benzene e There may be th
61. ed data by repeating steps 1 3 If you decide not to delete a memory stored data touch the No button to return to the Memory Clear Screen Memory Clear Processing Screen Memory Clear Screen The number of memories will change o2 Le0 N0 2 G AA Memory Title Memory Close Close Button The selected memory will be deleted and the numbers after the selected number will decrease by one 4 Touch the Close button Returns to the Measurement screen When you do not delete other memories touch the Close button Returns to the Measurement screen Erasing All 1 Match the Title to be deleted with the blue background positions Select the Title to be deleted 106 6 Measurement Tool Tool Box Screen 2 Touch the Title button This will delete the title All the memory data linked to the title will be deleted This will display the Memory Clear Confirmation screen Remove the selected memory title Are you sure will be displayed Memory Clear Memory Clear Screen Confirmation Screen Move title into the blue background to select it Memory All memorized a measurements a Yes Button linked to the selected Title Wenory Close No Button title will be displayed Title Button 3 Touch the Yes button Deleting Memory Please wait will be displayed Returns to the Memory Clear screen after deletion While the progress bar is running the deletion is
62. eed Step y LB Step Camera Filter Brand a Lighting Filter Brand o White Balance Step Be Unit of luminance 129 7 Meter Settings Setting Screen e 2 Select the desired white balance step to use White Balance Step Screen Blue bar indicates the value selected OK Button Cancel Cancel Button Measurement Screen Display Example BA5 0OMK GM2 5 BA10MK GM2 5 Default LB index 30MK after changes CC index 6 gt BA Step 10HK 1 GH Step 2 5 BA Step 5 OHK GH Step 2 5 3 Touch the OK button Confirms the settings and returns to Setting To return to Setting without confirming touch the Cancel button Setting Screen g Shutter Speed Step t LB Step Camera Filter Brand Lighting Filter Brand ft White Balance Sten The set content is displayed Unit of I luminance The white balance step is set 130 7 Meter Settings Setting Screen e 1 2 7 Selecting the Unit of illuminance Select the unit when measuring illuminance Models sold in some countries do not display illuminance and exposure in fc fc s due to legal restrictions In this case Unit of Illuminance button will not appear in Setting screen Unit of illuminance Screen Ix xs fe fe s Default Ix Ix s fe fc s Cancel 1 Touch the item Unit of Illuminance button on page 1 of Setting The unit of illuminance will be displa
63. een Preset No Preset Selection List Preset Name Target CCT LB Index Correction Value CC Index Correction Value 5 Edit each setting item Refer to the follow reference pages for editing each setting item e Preset Selection List P149 e Preset Name P151 e Target CCT P153 e LB Index Correction Value gt P156 e CC Index Correction Value P158 6 Touch the Close button Returns to Setting Preset editing is complete 148 7 Meter Settings 7 3 1 Displaying the Preset Selection List Select to display or not in the Preset Selection list in the Tool Box Display in the Preset Selection List Screen Displayed Hide Cancel 1 Touch the Preset Selection List button Display in the Preset Selection List will appear Preset Editing Display in the Preset Digital Screen Selection List Screen Preset No Displayed Preset Selection List Hide Preset Name Target CCT LB Index Correction Value CC Index Correction Value Cancel 149 Setting Screen _ _ 7 Meter Settings Setting Screen 2 Select the Displayed to set The selected icon will be displayed encircled in blue Display in the Preset Selection List Screen Displayed Displayed The selected button will ilk ce be displayed encircled in blue Cancel Cancel OK Button Cancel Button 3 Touch the OK button The set item is fixed and returns to the Prese
64. elect a shutter speed that will synchronize with your camera and flash system e If the triggering voltage of the flash used is extremely low the flash may not trigger In this case use 5 3 Measurement in Cordless Flash Mode P62 x 3 __ If necessary you can select a previously created Preset value from Preset Selection in the Tool Box P146 Tool Box Screen Preset Selection Screen Tool Box Screen p Digital Film p Digital Film p Preset Selection Digital gp Preset Selection Digital g Preset Selection Fi Im g Preset Selection Film A yg Memory Title yp Memory Title Memory Clear Memory Clear ke iranis n E e i P Memory Recal P Memory Recall A v Y g Radio Channel Zone g Radio Channel Zone Cancel The selected value is indicated by the blue background If no presets have been created the Preset Selection will be grayed out and touching the button will not display the Preset Selection Display You can omit this step if unnecessary 12 5 Measuring Light Sources Measurement Screen 8 Confirm the light measuring range Light Selection Ring When you return to the Measurement screen select Range L fie or Range H depending on the brightness of of the flash Measuring Button e Range L lo Select this when measuring small and low power flash units lower than 640Ix s Over will appear if flash power is too high Select Ran
65. en The Measuring Mode Selection screen will be displayed Measuring Screen Measuring Mode in Text Mode Selection Screen Text Mode in Fo Measuring Mode Ambient Light em EE Ambient Mode Mode CCT Cordless Flash Mode Lux Cord PC Flash Mode CCi Radio Triggering Mode LBi Ra 2 Touch an icon to select the measuring mode Select the desired measuring mode Making selection returns the display to previous measuring screen using selected mode Measuring Mode Measuring Screen Selection Screen in Text Mode Measuring Mode T 1 125 B 5000K a Target Ambient Mode CCT Cordless Flash Mode Hix Cord PC Flash Mode CCi Radio Triggering Mode LBi Ra Ex Ambient Light Mode Text Mode in Cordless Mode Cordless Mode e Ambient light includes continuous light sources such as natural light sunlight tungsten lamps or fluorescent lights e Flash light includes brief and intense burst of light sources such as electronic flash units or flash bulbs 23 4 Setting the Measuring Conditions 4 1 2 Selecting the Shutter Speed Flash Modes Only In any flash mode set the shutter speed 1 Touch the T Shutter Speed indication Measuring Screen in Text Mode Text Mode in i Cordless Mode U Fa Target 5000K CCT 5077K Hix 128lx s CCi 2 Select the desired shutter speed Soue Speed Sarean Shutter Speed 1 125 4 Shutter Speed OK Button Shutter
66. en measuring flash units select Range L a or Range H fo depending on the brightness of of the flash gt P86 gt P88 Measurements can now be made Measuring Button Measurements and display will take longer in light levels below 30Ix The LCD illumination will normally switch off during measurements to avoid influence to measurements 5 Memorize the measurement results Measurement results can be memorized To record measurements press Memory Button P95 The filter manufacturer can be selected by the item Lighting Filter Brand on the page 1 of Setting gt P127 48 4 Setting the Measuring Conditions 4 3 7 Displaying to Compare Light Sources Multi Lights Mode Displays comparative correction values from multiple measurements Multi Lights Screen Display Mode Icon Multi Lights Comparison Up to 4 light sources can be compared from Ato D Compensation value shows the difference between the selected color temperature by the radio button Displays the mode when measured Standard Selection Radio Button 1 Touch the Multi Lights icon on the Display Mode screen The Multi Lights screen will be displayed P29 2 Touch the A button The Measuring screen of A will be displayed Measurement Screen for Multi Lights Multi Lights Screen Touch the A button Measuring Mode Icon 49 4 Setting the Measuring Conditions
67. ent results can be memorized To record measurements press Memory Button P95 The filter manufacturer can be selected by the item Camera Filter Brand in page 1 of Setting P125 46 4 Setting the Measuring Conditions 4 3 6 Displaying in Lighting Filter Lighting Filter Mode Displays correction values and light source filter names required to adjust measured source to Target Color temperature You can select filter brand in advance in Setting LEE ROSCO E COLOUR or CINEGEL Lighting Filter Screen Target indication j a Measuring Mode Icon 7 d Denario en Measurement Value Lighting Filter Display Color Temperature Filter Brand Brand LEE CCT 5587K LB Index LBi 21MK1 Filter Name LB 1 8 CT STRAW CC Index CCi 1 7G Filter Name CCtt 1 8 PLUS GREEN J 1 Touch the Lighting Filter icon on the Display Mode screen The Lighting Filter screen will be displayed P29 2 Touch the Measuring Mode icon The Measuring Mode Selection screen will be displayed Select the desired measuring mode to use P22 3 Touch the Target indication Target CCT Input screen will be displayed P26 Set the desired color temperature number 47 4 Setting the Measuring Conditions 4 Press the Measuring Button to measure Light Selection Ring Turn the Light Selection Ring to select the range When measuring ambient light make sure to select Range L lo Wh
68. erature gt P26 Switches to the Target Color Temperature Input screen Displays the display mode P29 Switches to the Display Mode Selection screen 9 Display Item Indication Switches to the Item Selection screen gt P28 0 Tool Box Icon Switches to the Tool Box screen gt P89 Delta Icon in Ambient Light Mode only Channel Zone Icon C 700R in Radio Triggering Mode only 12 Displayed when differential measurement can be performed When there is no reference measurement value the icon is disabled When differential measurement cannot be performed the 4 icon is not displayed When is touched the displayed measurement is memorized and Contrast Function is activated When holding the Measuring Button the value differences of the memorized items except filter names and the current reading will be displayed When the Measuring Button is released the display will revert to memorized values of the first reading A graph displays the reference values When is touched the icon returns to and the values measured last are displayed Contrast Function is cancelled when the power is turned OFF Note Caution When the Contrast Function icon is displayed the Memory Button is disabled STD 01 When is touched it switches to the Radio Channel Zone screen P108 iy ___ When values are outside the display or measurement range Under Over or
69. f ey Le Backlight Brightness iy Auto Dimmer BEUR Xe Language it Radio System Preference M Reset Customized Items v A Close 137 7 Meter Settings Setting Screen e 2 Touch the desired brightness on the Backlight Brightness screen Select dark normal or bright Backlight Brightness Screen Dark Norma Normal Bright Bright The selected button will be displayed encircled in blue Cancel Cancel OK Button Cancel Button 3 Touch the OK button Confirms the settings and returns to Setting To return to Setting without confirming touch the Cancel button Setting Screen px Spectrum Y axis Scale Gy Auto Power Off Backlight Brightness 2 The set content is displayed Auto Dimmer Language Be Radio System Preference a Reset Customized Items Vv A Close The backlight brightness is set 138 7 Meter Settings Setting Screen e 7 2 11 Selecting the Auto Dimmer Time Select the time before the backlight dims after last use to save extra power or adjust the visibility under the surrounding light condition 20sec 40sec 60sec No Dimmer Auto Dimmer Screen 20 sec Default 40 sec 60 sec No Dimmer Cancel 1 Touch the Auto Dimmer button on page 2 of Setting The auto dimmer time will be displayed Setting Screen Auto Dimmer Screen 20 sec Be Spectrum Y axis Scale Ley Auto Power Off 40 sec Back
70. f film you are using Daylight type 5 500K Tungsten Type A 3 400K Tungsten Type B 3 200K e You can set the color temperature from 2 500K to 10 000K in steps of 10K 2 4 Setting the Measuring Conditions 4 2 2 Customizing Measuring Displays You can customize displayed information to see exactly what you need in single view 1 Touch the Display Item indication on the Measurement screen The Display item library screen will be displayed P34 2 Select the items to be displayed Selected items and the values will be displayed Measuring Screen Measuring Screen Measurement Screen Text Display Spectrum Display CRI Display gt P33 gt P36 Target 5000K CCT 5587K 0 0129 89 4 Display Item List No Indication Display Item Name Description 4 Color Temperature In Digital Mode Displays correlated color temperature Display In Film Mode Displays photographic color temperature Sl aa Displays deviation from the black body radiation i Ei illuminance Displays illuminance in lux or foot candle Hix DA Exposure Displays exposure in lux second or foot candle second CC Index Displays the CC correction value in CC index EP SESA Displays the CC corrected value in the compensation ET filter name The filter manufacturer is selected in the CC Lighting setting Filter Correction LB Index Displays the LB corrected value in LB index LB E Displays the LB corrected
71. ff before use e Although the LCD monitor is manufactured with very high precision technology with over 99 9 effective pixels there might be a few dead pixels Dead pixels that do not or always light up are not a malfunction e Do not use at altitudes above 2 000m 6 561 feet e Our company shall not be liable for any data loss caused by but not limited to malicious acts and control errors e You can install the software on the included CD ROM only when you agree with all articles in the license agreement that comes with the CD ROM e Be sure not to drop the meter or subject it to sudden impacts as the meter will be damaged e Do not store the meter in areas of high temperature of high humidity as the meter will be damaged e Be careful of condensation caused by sudden changes in temperature It will cause damage or malfunction of the meter e f the temperature goes below 10 C which may occur in the winter the response of the liquid crystal display will slow down greatly and the display will become difficult to read Between 0 10 C the liquid crystal display response will slow down somewhat but the meter will not be harmed Also if the temperature exceeds 50 C the liquid crystal display will darken and become difficult to read but when it returns to room temperature it will return to its normal condition e If the meter is left in direct sunlight a vehicle or near a heater the unit s temperature will rise and may result
72. g 6 Adjust Touch Pane Reset to factory A Edit User Information default settings Are you sure Factory Setting 173 8 Hardware Setting Screen 2 Touch the Yes button The factory setting confirmation message All measurements will be lost when you perform this operation Are you sure will be displayed Confirm again To return to the Hardware Setting screen without resetting to factory default settings touch the No button Factory Setting Confirmation Screen Factory Setting Confirmation All measurements wil be lost when you perform this operation Are you sure Yes Button No Button 3 Touch the Yes button G noT eE _ _ When the message Deleting Memory Please wait or the progress bar is displayed do not turn the power off Otherwise the meter may be damaged All measurement values are deleted and returns to the Hardware Setting screen English display is the default factory setting Factory Setting Deleting Screen Hardware Setting Screen Factory Setting Hardware Setting f Adjust Touch Pane Deleting Memory p Edit User Information Please wait f Factory Setting Close Button 174 8 Hardware Setting Screen 4 Touch the Close button The Language Selection screen is displayed Select the language to use P5 Language Selection Language Selection Screen Confirmation Screen Select Language Select Language English Fa T
73. g is set to the dark Menu Button or Display Mode Icon calibration position Display Mode Selection Screen Setting icon The user sets the functions depending on the intention e Customize the meter for e Edit a preset Close Button e Make a dark calibration e Display the information Display Mode Selection Screen Any Display Mode Icon Measurement Screen The user sets the measurement Tool Box Icon functions depending on the intention Toci Box Screen e Digital Film Mode Selection e Preset Selection e Memory Title Setting Radio Channel Zone Selection for C 700R only To the next page 12 3 Basic Operation Methods ___ From the previous page Select the measuring mode Ambient Light Flash Light Measuring Mode Selection Screen Cordless Cord Radio Triggering only for C 700R Target Indication If you have the target color temperature to achieve by Target Color Temperature Input Screen filtration please input If not skip this operation to go next Measurement Screen Measuring The LCD dims when measuring Measuring Screen EEE complete the LCD returns to the Measurement Screen previous user set brightness and the measurement results Memory Memory Button are displayed Pressing the Memory Button stores the displayed data with Tool Box Icon memory title set in Tool Box in advance and M1 appears i
74. g Button to measure Turn the Light Selection Ring to select the range When measuring ambient light make sure to select AN aie o SEome When measuring flash units select Range L le or creo Range H lo depending on the brightness of of the flash gt P86 gt P88 Measurements can now be made Measuring Button 43 4 Setting the Measuring Conditions e Graph display areas Ra R1 R15 are always displayed e Measurements and display will take longer in light levels below 30Ix The LCD illumination will normally switch off during measurements to avoid influence to measurements 4 Touch the Display Item indication to change The Display item library screen will be displayed CRI Screen Display Item Library R1 R2 R5 R6 Display Item Indication R9 R10 R11 R13 R14 R15 Cancel 5 Touch the desired Display Item Select the item to display above the graph Indication will be encircled in blue 6 Touch the OK button Returns to the CRI screen by the OK button When the Cancel button is touched it returns to the CRI screen without the display item being changed Display Item Library CRI Screen Of A Display Item Indication RB RGR OK Button Cancel Button 44 4 Setting the Measuring Conditions _ 4 3 5 Displaying in Camera Filter Camera Filter Mode Displays correction values and camera filter names required to adjust measured source to
75. g step of the camera and the shutter speed and iris setting step of the spectrometer match Is the differential measurement icon displayed Is Memory Full displayed when pressing the Memory Button Do you use a receiver that installs the PocketWizard system Or do you use a radio system of other brands or manufacturers Do the radio destination of the spectrometer that is a transmitter and the receiver match Did you set the same channel number to the transmitter and the receiver Are you mixing the Standard system and the ControlTL system 190 11 Troubleshooting Measure Some cameras can select 1 3 step 1 step and 1 2 step like a spectrometer Match the step of the spectrometer with the step of the camera Shutter Speed Step P120 The memory function cannot be used when the differential measurement icon is displayed Cancel the differential measurement mode The memory can store up to 99 values Clear unnecessary memory values in advance measure and memorize it Use a receiver that installs the PocketWizard system www pocketwizard com There are two types FCC amp IC 344 MHz band and CE 433 MHz band Check if the destinations frequency of the transmitter and the receiver are the same Check if the transmitter and the receiver use the same system either the Standard system or the ControlTL system and set the same channel number SEKONIC CORPORATION 7
76. ge H e Range H Select when measuring powerful flash units brighter than 640Ix s Under will appear if flash power is too low Select Range L 9 Press the Measuring Button Measurement will be taken with flash and the light source values will be displayed Because it affects measurement while measuring the LCD backlight will dim It is not a defect Measurement in Cord PC Flash Mode is complete 3 5 Measuring Light Sources Measurement Screen A CAUTION e Depending on the flash equipment used the flash may be triggered when the sync cord is connected to the Sync Terminal or when operating the Power Button Because there is the possibility of burns or negative effects on vision please handle with care e Do not trigger flash while skin or other objects are in contact with the flash tube Do not touch the flash tube after continuous flashes It may cause burns e Do not trigger flash while near the eyes of people or animals It may temporarily affect vision e The flash may be triggered suddenly Because there is the possibility of burns or negative effects on vision please handle with care Q noT oE e Ifthe triggering voltage of the flash used is extremely low the flash may not trigger In this care use 5 3 Measurement in Cordless Flash Mode P62 e When measuring flash bulbs make sure the shutter sync speed is set to the proper synchronization range of your camera
77. gistered order Memory Clear Screen Title Memory Title Button Close Button Memory Button 104 6 Measurement Tool Tool Box Screen 1 Touch and select the Memory Clear button in the Tool Box The Memory Clear screen will be displayed Tool Box Screen Memory Clear Screen g Digital Film gp Preset Selection Digital 3 p Preset Selection Film Blue bar indicates the item selected gp Memory Title Memory Clear Memory g Radio Channel Zone 02 5689K 3 A h en te ciaar a Close Button Title Button Memory Button Erasing Individual Values 1 Select the Title to display the memorized value you want to delete Then select the specific light source value under that title if more than one value has been memorized 2 Touch the Memory button This will display the Memory Clear Confirmation screen Remove the selected memory data Are you sure will be displayed Memory Clear Memory Clear Screen Confirmation Screen A T Select Title a hene 02 LeD NO 2 f Memory that ad you want to Memory clear a Yes Button Memory Tiele Memory Glose No Button Button 105 6 Measurement Tool Tool Box Screen 3 Touch the Yes button A progress bar will appear while the memory is being deleted When the memory has been cleared the meter will return to the Memory Clear Screen You can clear delete additional memories stro
78. h Enlarged Display Target 5000k HE 5587K duv Q 0129 Measurement mie 89 4 results are displayed The maximum display value of the Y axis can be selected by the item Spectrum Y axis Scale icon in page 2 of Setting P133 T Memorize the measurement results Measurement results can be memorized To record measurements press Memory Button gt P95 37 4 Setting the Measuring Conditions 4 3 3 Displaying in Spectrum Comparison Spectrum Comp Mode The spectrum comparison displays and compares the current measurement and up to 2 memorized values in spectrum graph Spectrum Comp Screen Target Indication Measuring Mode Icon Display Mode Icon Target 5000K Spectrum Comparison Current Measurement Display CCT 5587K Auv 0 0129 Current Measurement LED NO 4 05 CCT 4331K Auv 0 0093 Color temperature LED N0 4 04 display area Memory Selection Icon CCT 3079K Auv 0 0007 Line Graph Display ON OFF check box 0 o E 380 460 540 nm 1 Touch the Spectrum Comp icon on the Display Mode screen The Spectrum Comp screen will be displayed P29 2 Touch the Measuring Mode icon The Measuring Mode Selection screen will be displayed Select the desired measuring mode to use P22 3 Touch the Target indication Target CCT Input screen will be displayed P26 Set the desired color temperature number 38 4 Setting the Measuring Conditions
79. h Mode This may also result in damage to the product e When using flash with high voltage there is a danger of electric shock if you touch the Sync Terminal Handle the flash with care when using for measurement 1 Touch the Tool Box icon Touch and select the Digital Film button P90 Tool Box Icon on the Measurement Screen Tool Box Screen T 1 125 B P 7 00 ox j i Target 5000K p Digital Film The set CCT contentis K displayed Hix CCi LBi Ra 68 5 Measuring Light Sources Measurement Screen 2 Select the type of camera Digital or Film used Touch either the Digital or Film button Digital Film Screen Sore Digital Film The selected icon will be displayed encircled in blue OK Button EE E Cancel Button 3 Touch the OK button Confirm and return to the Measurement screen To return to the Measurement screen without confirming touch the Cancel button 4 On the Measurement screen touch the Measuring Mode icon and select the Cord PC Flash Mode icon on the next screen Select the measuring mode P22 Measuring Mode Measurement Screen Selection Screen Measurement Screen Target 5000K En Measuring Mode T 1 125 B z Target 5000K Ambient Mode CCT CCT Cordless Flash Mode Lux Hix Cord PC Flash Mode CCi Radio Triggering Mode LBi Ra 4 69 5 Measuring Light Sources Measurement Screen
80. he Light Range Change and use the light range depending on the brightness of the flash Light Selection Ring Status Bar Display Content Dark Calibration Select for dark calibration only Measurement cannot be Position made in this position Select for ALL ambient light measurement and low power flash units lower than 640Ix s Select for powerful flash units brighter than 640Ix s only Turn the Light Selection Ring and select the desired range The set range will be displayed on the LCD screen s status bar RANGE H Status Bar RANGE L RANGE H RANGEL Light Selection Ring 88 6 Measurement Tool Tool Box Screen 6 Measurement Tool Tool Box Screen Selecting Screens from the Tool Box Touch the Tool Box BEA icon in the Measurement screen to display the Tool Box screen P17 You can select screens from the Tool Box as follows Memory Clear Digital Film Tool Box gt P104 gt P90 Son ao eo m 11 Digita mN 9 Memory Clear fy Too Box Digital Film Digital Film Pte omo i p Preset Selection Digital 01 FL 001 Pte G noo eee 7 Memory Reca EE amp Radio Channel Zone Memory Recall STD 01 CTL 02 ABC Preset Selection gt P98 When Using Digital P92 Memory Reca Preset Selection Digital The set content is displayed in yellow letter at the lower right hand corner of the button 0 ED NO Vie BEUTNUe PC a 02 LED NO 2
81. he measurement screen will appear when operational Dark Calibration Process Screen Dark calibration in progress Please wait 2 Before Use amp _ Lk3 _ __ ___ _ e When the Light Selection Ring is not set to the dark Dark Calibration Position calibration position the message Please set Light Confirmation Screen Selection Ring for dark calibration is displayed Set the Light Selection Ring to the dark calibration position Ey to calibrate the system Please set Light Selection Ring for dark calibration e f dark calibration is not successful Dark calibration Dark Calibration failed Please check Light Selection Ring position is Confirmation Screen displayed Set the Light Selection Ring to the dark calibration position Ey to calibrate the system Please check Light Selection Ring position 6 Press the Measuring Button to measure Turn the Light Selection Ring to select the range Fa When measuring ambient light make sure to select Range L i When measuring flash units select Range L ej or Range H 1O depending on the brightness of of the flash gt P86 gt P88 When the Measuring Button is pressed at the dark calibration position the message Measurement failed Please check Light Selection Ring position is displayed After you confirmed touch the Measurement failed OK The Measurement screen will be displayed eetiar nie caisinn 2 Before Use
82. he selected button will ae as be displayed encircled in FAM GEP FAY GEF blue OK Button 5 Touch the OK button The language can be switched anytime P141 6 Dark calibration starts Dark calibration in progress Please wait and status bar will appear whil calibration The Measurement screen will appear when operational Dark Calibration Process Screen Measurement Screen Target 5000K E CCT Dark calibration in progress Please wait Lux CCi LBi Factory setting is completed 175 9 Appendix _ 9 Appendix CECT Description Color temperature refers to the chromaticity of a heated object commonly refer to as a black body that will vary according to its temperature The color temperature is measured in units of Kelvin K and refers to the temperature of a heated object at a given color or chromaticity The higher color temperature is the bluer the light and the larger the Kelvin value becomes The lower the color temperature is the redder the light and the smaller the Kelvin value becomes A figure that plots the changes of color temperatures on an xy chromaticity diagram is called the black body radiation locus Color Temperature Not all light sources match the black body radiation locus when measuring light Correlated sources Color In this case the correlated color temperature is used The correlated color Temperature temperature is a color temperature obta
83. hing the displayed screens P18 oO Menu Button Press to shift display to Display Mode Selection screen 2 Memory Button Press after measuring to record the measured data Press after measuring to record the measured data measuring to record the measured data Battery Cover a Battery Cover Secures the batteries Secures the batteries batteries D Tripod Socket Female mounting threads 1 4 20 for hands free mounting on tripods The USB connector for connecting to the PC with the installed USB Connector application and USB bus power USB terminal Mini B 5pin EJ Sync Terminal For measuring in Flash Light Cord PC Mode plug in an optional sync cord l Strap Eyelet Used to attach the included Used to attach the included strap D Battery Holds the batteries Insert the batteries in the correct direction Compartment 2 Before Use 2 Before Use 24 Attaching the Strap 1 Pass the strap included through the outer hole of the Strap Eyelet 2 Pass the opposite end of the strap through the loop at the end of the strap Strap Eyelet Infants or toddlers may accidentally wrap the strap around their neck so please place it in a location out of their reach There is a danger of suffocation A CAUTION e Infants or toddlers may accidentally grab the strap and swing the product so please place it in a location out of their reach as the meter may be damaged by impacts e Be careful th
84. hting Filter LB index MK Filter No Filter Name CCT K Conversion 0x OM ale 4 Filter No Filter Name CC Filter Equivalent Displayed in C 700 C 700R 182 9 Appendix __ 9 3 Specifications Type e Spectrometer with CMOS linear image sensor for digital or film cameras Light receiving method e Incident light Light receptor e White diffuser fixed type Light receptor element e CMOS linear image sensor 128 pixels Measurement system e Measuring mode Ambient light e Measurement type e Display mode e Flash light e Digital e Film e Illuminance e Digital Film e Illuminance luminous exposure Measurement range e luminance in color temperature measurement e lluminance e Ambient light e Flash light Ambient light mode Cord flash mode with sync cord Cordless flash mode Radio triggering flash mode C 700R Only Color temperature measurement based on color matching function Correlated color temperature Color temperature measurement based on approximation of film spectral characteristics Photographic color temperature Complies with JIS C1609 1 2006 general A class illuminometer Text mode Spectrum mode Spectrum Comp mode CRI mode Camera Filter mode Lighting Filter mode Multi Lights mode WB Corr mode lux Ix Ix per second Ix s foot candle fc foot candle per second fc s in limited version only Ambient light 5Ix 200 000
85. hutter speed step will be displayed Setting Screen Shutter Speed Step y LB Step Camera Filter Brand Lighting Filter Brand a h ite Balance Step a Unit of I luminance Shutter Speed Step Screen 1 step 1 3 step 1 2 step 2 Touch the desired shutter speed step to use Select from 1 step 1 3 step or 1 2 step Shutter Speed Step Screen ay Speed ste 1 step 1 3 step 1 2 step Cancel 121 1 step 1 3 step 1 2 step Cancel The selected value will be displayed encircled in blue OK Button Cancel Button 7 Meter Settings Setting Screen e 3 Touch the OK button Confirms the settings and returns to Setting To return to Setting without confirming touch the Cancel button Setting Screen g Shutter Speed Step The set content is displayed y LB Step Camera Filter Brand Lighting Filter Brand White Balance Step Unit of I luminance The shutter speed step is set 122 7 Meter Settings Setting Screen e 7 2 3 Selecting the LB Step Select the LB index display step from 1MK 1daMK no decimal point step and 0 1daMK with decimal point step Ex 38MK is displayed as 38MK in 1MK step 4MK in 1daMK step and 3 8MK in 0 1daMK step LB Step Screen 1MK7 Default IdaMK 0 1daMK7 Cancel 1 Touch the item LB Step button on page 1 of Setting The LB step
86. id possible damage caused by battery leaking 2 Before Use _ 23 Power ON OFF Power ON Light Selection Ring 1 Turn the Light Selection Ring to set to the dark calibration position E 2 Press the Power Button The meter will turn on and the Opening screen will be displayed for 2 seconds Power Button C 700 Opening Screen C 700R Opening Screen SPECTROMASTER SPECTROMASTER c 700 cC ZOOR PocketWizard e The blue lettered SEKONIC logo screen is displayed Logo Screen after battery replacement and 24 hours after power OFF e Movement of the blue status bar indicates that the meter is checking its memory and preparing to operate Do not turn the power OFF Otherwise the meter may be damaged 2 Before Use 3 Select the language Appears only when turned ON for the first time The Language Selection screen is displayed Select the language to use Language Selection Language Selection Screen Confirmation Screen Select Language Select Language Engl ish Engl ish A blue highlight will appear ii BE behind the H CE ees selected button 4 Press the OK to select the language The language can be switched at any time P141 5 Dark calibration The C 700 series measuring system must be calibrated before use Turn Light Selection Ring to calibration indication Dark calibration in progress Please wait and the status bar will appear while calibrating T
87. ight Brightness Ky Auto Dimmer 60 sec Language Laas ee No Dimmer Le Radio System Preference a Reset Customized Items h A Close 139 7 Meter Settings Setting Screen e 2 Touch the desired time on the Auto Dimmer screen Select 20sec 40sec 60sec or No Dimmer Auto Dimmer Screen Ne r 20 sec 20 sec 40 sec 40 sec 60 sec The selected No Dimmer R button will be displayed encircled in blue Cancel 0K Cancel OK Button Cancel Button 3 Touch the OK button Confirms the settings and returns to Setting To return to Setting without confirming touch the Cancel button Setting Screen px Spectrum Y axis Scale Gy Auto Power Off a Backlight Brightness Auto Dimmer adie The set content is displayed Language Be Radio System Preference a Reset Customized Items Vv A Close The auto dimmer time is set 140 7 Meter Settings Setting Screen e 7 2 12 Selecting the Language Select the language displayed in the meter setting or menu from English Japanese or Chinese Language Screen English HARA AN GEF Cancel 1 Touch the item Language button on page 2 of Setting The language will be displayed You can change the language set when power is turned on for the first time Setting Screen Language Screen English a Spectrum Y axis Scale it Auto Power Off Gage ty Backlight Brightness
88. in damage Please be careful when using the meter in these types of locations e f the meter is left where corrosive gases may be generated the gases may affect the product and may result in damage Please be careful when using the meter in these types of locations e When disposing of the meter follow the rules of disposal in your area Maintenance Notes e Be careful not to let the Light Receptor become dusty dirty or scratched as this may affect the precision of the measurement e If the meter becomes dirty wipe it with a dry soft cloth Never use organic solvents such as thinner or benzine __ e For used batteries dispose of them according to the rules of your area or bring them to a battery recycling shop near you Insulate plus and minus terminals with tape or other insulation material e Do not remove the cover e Do not disassemble the batteries E Intended Usage The meter is designed for e Measuring color temperatures and illuminance of natural or artificial lights for photographs videos and movies e Displaying the correction values of filters for camera or lighting to match to the target color temperature e Managing the lighting lamps aging degradation by checking the color temperature e Managing the viewing light source by color temperature for printing color proof digital film production etc e Check the quality of light source in color rendering index Main feat
89. in progress The process may require time depending on the number of memories to be deleted Do not perform other work When you do not delete the memories touch the No button Returns to the Memory Clear screen Memory Clear Processing Screen Memory Clear Screen The number of memories will change After the a selected aoa LED Ns memory and ss 2 its linked data Memory is deleted the contents pce 416k A of title 01 are re ee displayed Title Werory Close Close Button 4 Touch the Close button Returns to the Measurement screen 107 6 Measurement Tool Tool Box Screen 6 4 Setting the Radio Channel C 700R Only Set the radio channel zone to use E Setting ControlTL Channels Radio Channel Zone ControlTL Channel Screen STD CTL Tab Channel Number Zone Icon FCC amp IC 1 20CH CE 1 3CH OK Button Cancel Button 108 6 Measurement Tool Tool Box Screen 1 Touch the Radio Channel Zone button in the Tool Box The radio channel zone will be displayed 2 Touch the CTL tab When Radio Channel Zone is selected the CTL tab comes forward Radio Channel Zone ControlTL Channel Screen Tool Box Screen g Digital Film p Preset Selection Digital g Preset Selection Fi Im gp Memory Title Memory Clear Memory Recal g Radio Channel Zone Cancel 3 Select the channel number FCC amp IC 1 20 CE 1 3
90. ined by drawing an isotemperature line from the black body radiation locus which matches the measured value Photographic Color Temperature Color temperature calculated by using the ratio of R G and B characteristics obtained by measurement to match to the characteristic of film Liaht This refers to the electromagnetic wavelength ranging from 380nm to 780nm g that can be detected by the human eye Black Bod Theoretically this is an object that absorbs all wavelengths and when heated y emits light equivalent to the applied color temperature This refers to the light emitted by a black body The amount of energy released for each wavelength changes with the applied color temperature resulting in visible color variations Black body Radiation Expressed in absolute Kelvin temperature with units of K O zero K is equivalent to 273 15 C or 459 67 F The deviation between the correlated color temperature and the black body radiation locus When the correlated color temperature is above the black body radiation locus a sign is assigned when below a sign is assigned An index that provides color rendering properties the hue of object color of a light source It expresses the difference of the hue of object color against a basic light source There are individual CRI Ri and average CRI Ra which is expressed by the average value from R1 to R8 176 LB Index LB Filter CC Index CC Filter Number
91. l g Preset Selection Film gp Memory Title Memory Clear Memory Recal Radio Channe Zone Cancel 2 Touch the STD tab Standard channels will be displayed Radio Channel Zone Standard Channel Screen STD Tab Channel Number 112 6 Measurement Tool Tool Box Screen 3 Select the channel number 1 32 Select the channel number that you want to use Radio Channel Zone Standard Channel Screen Channel Number 1 32 Cancel 4 Touch the Zone icon When a channel number is set to 17 to 32 zones A B C D will appear to select Select the zone to trigger the flash Channel 1 to 16 No zone setting Channel 17 to 32 Up to 4 A B C D can be set The selected zone will be displayed and encircled in blue Radio Channel Zone Standard Channel Screen STD Tab Zone Number Icon Channel Number 17 32 OK Button Cancel Button 5 Touch the OK button Confirm and return to the Measurement screen To return to the Measurement screen without confirming touch the Cancel button 113 6 Measurement Tool Tool Box Screen 6 Confirm the set channel and zones on the Measurement screen You can see the settings on the button at the lower left hand corner Measurement screen T 1 125 A 5000K Target CCT Hix Ra emio e The set content is displayed The Standard channel is set e Touching the Radio Channel Z
92. ly 84 When Over Under or Out of Display is Displayed 86 5 7 1 Display of Over Under or Out of Display 86 5 7 2 Changing the Light Range 88 6 Measurement Tool Tool Box Screen 89 WA Selecting Digital Film 90 MEP Setting Preset Contents Preset Selection Screen 92 ME Using the Memory Function 95 6 3 1 Naming Memorized Measurement Values 95 6 3 2 Recalling Measurement Results Memory Recall Screen 98 6 3 3 Deleting Saved Measurement Results Memory Clear 104 ML Setting the Radio Channel C 700R Only 108 viii 7 Meter Settings Setting Screen 7 1 1 7 2 1 7 2 2 Taa 7 2 4 7 2 5 7 2 6 TEEN 7 2 8 7 2 9 7 2 10 7 2 11 7 2 12 7 2 13 7 2 14 7 3 1 72 733 7 3 4 7 3 5 7 5 1 Setting Items Item List Customize Item Specifications Selecting the Shutter Speed Step Selecting the LB Step Selecting the Camera Filter Brand Selecting the Lighting Filter Brand Selecting the White Balance Step Selecting the Unit of Illuminance Selecting the Spectrum Y axis Scale Selecting the Auto Power Off Time Selecting the Backlight Brightness Selecting the Auto Dimmer Time Selecting the Language Selecting the Radio System Preference C 700R Only Reset Customized Items Preset Editing Displaying the Preset Selection List Setting the Present Name Setting the Preset Target Color Temperature Setting the LB Index Correction Value Setting the CC Index Correction Value Dark Calibration Product Information Display Regulati
93. m icon on the Display Mode screen A spectrum distribution graph screen will be displayed P29 2 Touch the Measuring Mode icon The Measuring Mode Selection screen will be displayed Select the desired measuring mode to use P22 3 Touch the Target indication Target CCT Input screen will be displayed P26 Set the desired color temperature number 4 Touch the Display Item indication to change The Display item library screen will be displayed P34 Touch the desired Display Item and OK button 36 4 Setting the Measuring Conditions 5 Press the Measuring Button to measure Light Selection Ring Turn the Light Selection Ring to select the range When measuring ambient light make sure to select Range L lo When measuring flash units select Range L ae or Range H fo depending on the brightness of of the flash gt P86 P88 Measurements can now be made Measuring Button Measurements and display will take longer in light levels below 30Ix The LCD illumination will normally switch off during measurements to avoid influence to measurements ah Touch the Magnifying Glass icon on the screen The spectrum distribution graph will be enlarged The enlarged graph is displayed on the whole screen landscape To return to the Spectrum screen touch the Magnifying Glass icon on the enlarged spectrum distribution graph Spectrum Screen Spectrum Distribution Grap
94. make them easier to select view and use data later To use this function the order of operation Create memory title Measure light source Press Memory button to memorize Untitled_ The factory default name is displayed DEL e Atitle can be a maximum of 16 alphanumeric characters e Up to 99 titles can be created More than one measurement can be stored under one title 95 6 Measurement Tool Tool Box Screen 1 Touch and select the Memory Title button in the Tool Box The Memory Title screen will be displayed Tool Box Screen Memory Title Screen Ve nory Title p Digital Film p Preset Selection Digital Untit ed_ p Preset Selection Film DEL Input p Memory Title Section Memory Clear Memory Recal p Radio Channel Zone Cancel 2 Enter the memory title P19 Use the keyboard to create a name for the measured light Memory Title Screen LED N0 4_ DEL OK Button Cancel Cancel Button 3 Touch the OK button Confirm and return to the Measurement screen To return to the Measurement screen without confirming touch the Cancel button The memory title is entered The memory title needs to be entered before memorizing The title cannot be changed after memorizing 96 6 Measurement Tool Tool Box Screen 4 Measure light Light Selection Ring Press Measuring Button to take a measurement Turn the Light Selection Ring
95. mmer Ley Language tt Radio System Preference M Reset Customized Items v A Close 133 7 Meter Settings Setting Screen e 2 Select the desired spectrum y axis scale Select from relative auto or spectral radiant intensity Spectrum Y axis Scale Screen Blue bar indicates the value selected Cancel 0K Cancel OK Button Cancel Button 3 Touch the OK button Confirms the settings and returns to Setting To return to Setting without confirming touch the Cancel button Setting Screen Spectrum Y axis Seale The set content is displayed t Auto Power Off Be Backlight Brightness y Auto Dimmer y Language Be Radio System Preference a Reset Customized Items v A Close The spectrum y axis scale is set 134 7 Meter Settings Setting Screen e 7 2 9 Selecting the Auto Power Off Time Select the time before the power automatically turns off after last use Smin 10min 20min No Auto Power Off When No Auto Power Off is set the automatic power OFF function is not activated Auto Power Off Screen wer OTT 5 min Default 10 min 20 min No Auto Power Off Cancel 1 Touch the item Auto Power Off button on page 2 of Setting The auto power off time will be displayed Setting Screen Auto Power Off Screen hated 5 min Be Spectrum Y axis Scale it Auto Power Off 10 win t Backlight Brightness tty Aut
96. n Tool Box Screen the Status Bar Memory Recall Button Reference to Stored Memory Recall Screen Value Memory Selection OK Button Memory Recall Mode Screen Displays the measured data stored in the selected memory 13 3 Basic Operation Methods __ 32 Screen and Operation 3 2 1 Basic Screen and Operation The touch screen display enables selecting Display Modes and settings with the touch of your finger Measurement Screen The Measurement screen is displayed after the meter is turned ON and the dark calibration is complete Measurements can be made in the Text Spectrum Spectrum Comparison CRI and Camera and Lens Filter and White Balance Correction modes For details of Display Modes please refer to 4 3 Selecting the Display Mode P29 Pressing the Menu Button O returns the meter to the Display Mode Selection screen Measuring Screen in Text Mode 1 2 o pe 5 CCT 3 6 ux 7 Ci 8 LB 9 Ra 10 11 12 Res The display changes depending on the set measuring mode For this description all icons and menus are displayed 14 Item List Part Name Status Bar Measuring Mode Icon 4 fe Target Indication D gt Display Mode Icon 3 Basic Operation Methods __ Description Displays the setting contents P16 Displays the measuring mode P22 Switches to the Measuring Mode Selection screen Displays the reference color temp
97. n you want to change Target 5000K EB Target 5000K E MA a Touch the desired CCT ana New Bi eA LBu Display Item Display Item Indication will be duv mee appears fc encircled in blue CCi 1 7G OK Button LBi Ra Cancel Cancel Button Models sold in some countries do not display fc fc s due to legal restrictions 34 4 Setting the Measuring Conditions 6 Press the Measuring Button to measure Light Selection Ring Turn the Light Selection Ring to select the range When measuring ambient light make sure to select Range L lo When measuring flash units select Range L a or Range H 1o depending on the brightness of of the flash gt P86 gt P88 Measurements can now be made Measuring Button It may take longer time in case of taking measurement under low light under 301x It is not defect that LCD backlight becomes darker while taking measurement to avoid any influence T Memorize the measurement results Measurement results can be memorized To record measurements press Memory Button P95 35 4 Setting the Measuring Conditions 4 3 2 Displaying in Spectrum Graph Spectrum Mode Displays three user selected values and spectral distribution graph Measuring Mode Icon Display Item Indication Spectrum Screen Target Indication Target 5000K Display Mode Icon CCT 5587K Auv 0 0129 89 4 Spectrum Display 1 Touch the Spectru
98. nual e The contents of this operating manual may be reproduced for non commercial purposes and for personal use only However the reproduced material must contain the copyright notice of our company e The screens in this operating manual may differ from the actual screens Colors letters etc E Accompanying Accessories The following items are included with the SPECTROMASTER C 700 C 700R Confirm if any accessories are missing after unpacking If something is missing contact the sales agent Batteries size AA and a USB cable are not included Neck Strap Soft Case KO lt lt lt S PLL p jas jai Safety Precaution CD ROM Operating Manual C 700 Series Utility SEKONIC English A Safety Precaution E For Proper Operation Before using this product please read this Safety Precautions for proper operation ZA WARNING possi A CAUTION amp LELI e mOceyalc Jal cs E Safety Precautions E Intended Usage E Intended Users E Restrictions E Accompanying Accessories 1 Parts Designations and Functions MEE Parts Designations MEP Parts Functions 2 Before Use MPS Attaching the Strap FEJ installing the Batteries FEJ Power ON OFF MPL Checking the Battery Capacity AJ Automatic Power OFF Function MP2 Changing Batteries During Measurement 3 Basic Operation Methods GES Basic Operation Flow WEP Screen and Operation 3 2 1 Basic
99. o Dimmer 20 min Language pee No Auto Power Off Le Radio System Preference a Reset Customized Items h A Close 135 7 Meter Settings Setting Screen e 2 Touch the desired time on the Auto Power Off screen Select 5min 10min 20min or No Auto Power Off Auto Power Off Screen 5 min 5 min 10 min 10 min 20 min 20 min The selected No Auto Power Off No Auto Power Off button will be displayed encircled in blue Cancel Cancel OK Button Cancel Button 3 Touch the OK button Confirms the settings and returns to Setting To return to Setting without confirming touch the Cancel button Setting Screen px Spectrum Y axis Scale Auto Power Off te The set content is displayed a Backlight Brightness Auto Dimmer Language Be Radio System Preference a Reset Customized Items Vv A Close The auto power off time is set 136 7 Meter Settings Setting Screen e 7 2 10 Selecting the Backlight Brightness Select the LCD backlight brightness from Dark Normal or Bright to save extra power or adjust the visibility under the surrounding light condition Backlight Brightness Screen Dark Normal Default Bright 1 Touch the item Backlight Brightness button on page 2 of Setting The backlight brightness will be displayed Setting Screen Backlight Brightness Screen Dark a Spectrum Y axis Scale it Auto Power Of
100. ode To cancel standby mode touch the screen or press the Menu Button V NOTE When the icon stops blinking before triggering the flash or when you want to take measurements again press Measuring Button again Measurement in Cordless Flash Mode is complete 66 5 Measuring Light Sources Measurement Screen A CAUTION e Do not trigger flash while skin or other objects are in contact with the flash tube Do not touch the flash tube after repeated flashes It may cause burns e Do not trigger flash while near the eyes of people or animals It may temporarily affect vision e The flash may be triggered suddenly Because there is the possibility of burns or negative effects on vision please handle with care G noT eE i e If the flash output power is too weak compared to the surrounding light the meter may not detect the flash output In this case use 5 4 Measurement in Cord PC Flash Mode P68 e Pulsed light sources such as fluorescent lights or special lighting could cause the meter to take cordless flash measurements in rare cases In these situations use 5 4 Measurement in Cord PC Flash Mode P68 e If the Light Receptor detects a sudden and bright change in lighting intensity the meter may mistakenly take a measurement To avoid this take 5 4 Measurement in Cord PC Flash Mode P68 e Because the light radiated from a flash bulb gradually builds the meter will not detec
101. on Display 8 Hardware Setting Screen EA Adjust Touch Panel Edit User Information Factory Setting 115 115 117 118 119 120 123 125 127 129 131 133 135 137 139 141 143 145 146 149 151 153 156 158 160 163 165 166 168 171 173 9 Appendix EES Glossary EE Filter Types BEE Specifications ME Legal Requirement 10 Optional Accessories 11 Troubleshooting 176 176 178 183 187 188 189 1 Parts Designations and Functions Aa Parts Designations Front View Rear View Light Receptor Light Selection Ring Power Button Display Panel Measuring Button D Tripod Socket Memory Button Battery Cover Latch Battery Cover O Menu Button Bottom View Battery Cover Section Strap Eyelet Ceo ay Sync Terminal O USB Connector D Battery Compartment 1 Parts Designations and Functions 4 2 Parts Functions The following table lists the functions of each part Part Name Functions Point light receptor directly at light source during reading Head ry cgn Receptor rotates 270 degrees to aid reading Light Selection Rotate to select dark calibration normal measuring range or high Ring range for flash C Power Button Press to turn PrsstotumONOF Displays the setting screens and measurement screens The built Display Panel in touch panel function enables setting selection or operation by touc
102. one button on the Measurement screen will display the Radio Channel Zone screen The background color is black e When shifted to the Radio Channel Zone screen by the Radio Cancel Zone button touch the OK button or Cancel button to return to the Measurement screen Measurement Radio Channel Zone Radio Channel Zone Screen ControlTL Channel Screen Standard Channel Screen T 1 125 Fa Radio Channe Zone Radio Channe Zone STD CTL STD CTL Target 5000K CCT Hix CCi LBi Ra Cancel OK Cancel OK Cancel Button Button Button Button e When you set Radio Channel Zone from either screen the last settings are reflected on both screens 114 7 Meter Settings Setting Screen e Setting Items Here you can customize your meter for your preference in advance Display Mode Selection Screen rA Y Spectrum Spectrum Comp r fa ay Camera Lighting Filter Filter 5 te Setting Icon Setting Setting Setting Setting Page 1 Screen Page 2 Screen Page 3 Screen Sa SCR CT Setting 0 Setting 0 Setting 0 Customize Customize Edit a preset Ley Shutter Speed Step Ley Spectrum Y axis Scale Relative Ms Preset Editing Digital 1 step tt LB Step tH Auto Power Off a Preset Editing Film 1MK 1 5 min Camera Filter Bran WRATTEN 2 LEE a Lighting Filter Brand Backlight Brightness Auto Dimmer o Dark Calibration LEE
103. ose who are sensitive to flash or other strong lights photosensitivity and they may be negatively affected by light Therefore be careful when people are nearby during measurement 57 5 Measuring Light Sources Measurement Screen 52 Measurement in Ambient Light Mode select Ambient Light Mode when taking measurements of natural light Sunlight and continuous light sources such as LED tungsten lamps and fluorescent lights Lk3 i _______ Do not look directly into sunlight or other strong light when measuring It may cause severe eye damage or even loss of vision 1 Touch the Tool Box icon Touch and select the Digital Film button P90 Tool Box icon on the Measurement Screen Tool Box Screen Target 5000K Ea Ea t The set content is displayed in p Memory Title yellow Ci p letter at the lower right hand corner of the button CCT Lux 58 5 Measuring Light Sources Measurement Screen 2 Select the type of camera Digital or Film used Touch either the Digital or Film button Digital Film Screen Sore Digital Film The selected icon will be displayed encircled in blue OK Button E E Cancel Button 3 Touch the OK button Confirm and return to the Measurement screen To return to the Measurement screen without confirming touch the Cancel button 4 On the Measurement screen touch the Measuring Mode icon
104. osition of touch panel display P168 Information P171 Factory Setting pee 7 display and setting contents to the factory default Closes the Hardware Setting screen and Perform Dark calibration 4 Edit User Edit user information to display the User Information screen in Setting 166 8 Hardware Setting Screen __ 1 While holding the Menu Button O press the Power Button Until the Hardware Setting screen is displayed do not release the Menu Button and the Power Button If you release the button before the Hardware Setting screen is displayed the Measurement screen will be displayed The Hardware Setting screen is displayed SEKONIC S S Menu Button O Power Button 2 Touch the desired menu item The setting screen of the selected item will be displayed Refer to the explanations on the following page for each item setting 3 When finished touch the Close button Switches to the Dark Calibration Process screen and returns to the Measurement screen 167 8 Hardware Setting Screen 8 1 Adjust Touch Panel Adjust the position of touch panel display Adjust Touch Panel Screen Touch the center of cursor 1 Touch the Adjust Touch Panel button on the Hardware Setting screen Touch the center of cursor will be displayed Hardware Setting Adjust Touch Panel Screen Screen Hardware Setting Adjust T
105. ouch Pane Touch the center A Edit User Information of cursor fi Factory Setting 168 8 Hardware Setting Screen 2 Touch the center of the white cross in the upper left corner of the screen The touch position will be shown with a red cross cursor and the white cross cursor will move to the next position Adjust Touch Panel The touch position is showed The white cross move to Screen with a red cross cursor the next position Touch the center of cursor Touch the center Touch the center of cursor of cursor 3 Repeat in 7 places Continue and repeat in 7 places The screen of Press the OK to determine the touch panel adjustment will be displayed Adjust Touch Panel Confirmation Screen Press the OK to determine the touth panel adjustment Cancel 4 Touch the OK button Adjustment of touch panel is completed and returns to the Hardware Setting screen To return to the Hardware Setting screen without adjusting the setting touch the Cancel button Touch panel adjustment is completed 169 8 Hardware Setting Screen When a place far from the white cursor is touched the screen blinks Do it again Adjust Touch Panel Screen 170 8 Hardware Setting Screen __ 82 Edit User Information User information can be input in this screen User Information Screen Edit User Information Unnamed_ DEL Cancel Up to 16 alphanumeric character
106. ower and can only trigger flash Standard Channels The C 700R is designed for use with PocketWizard radios There are 32 meter channels Channels No 1 16 are single channels Channels No 17 32 can have 4 zones A B C D 77 5 Measuring Light Sources Measurement Screen 5 5 2 Setting the Radio Channel The radio channel can be set from the Tool Box or from the channel indication in the lower light corner of the Measurement screen For how to set the channel from the Tool Box refer to the Tool Box item P108 1 Touch the Tool Box icon Touch and select the Digital Film button P90 Tool Box Icon on the Measurement Screen Tool Box Screen Target 5000K E The set CCT content is displayed Hix g Memory Title CCi LBi p Radio Channel Zone l Ra Close 2 Select the type of camera Digital or Film used Touch either the Digital or Film button Digital Film Screen Digital The selected icon will be displayed encircled in blue Film OK Button Cancer Cancel Button 78 5 Measuring Light Sources Measurement Screen 3 Touch the OK button Confirm and return to the Measurement screen To return to the Measurement screen without confirming touch the Cancel button 4 On the Measurement screen touch the Measuring Mode icon and select the Radio Triggering Flash Mode icon on the next screen Sel
107. pacity the meter will automatically turn off 20 minutes after the last button is pressed V NOTE m e All measurements settings and indications are saved in memory even after the meter has automatically turned off When the power is turned ON they will be displayed again e The automatic power off time setting can be selected according to your needs in the settings gt P135 e f while in transport the Power Button is inadvertently and continually pressed in the meter will turn ON for about 1 minute and then turn automatically turn OFF to save battery power Power Button 10 2 Before Use 26 Changing Batteries During Measurement e Please make sure the power is OFF when replacing batteries If left ON the meter circuit could be damaged and measurements taken during the last operation will not be saved e f an unexpected display appears on the LCD during battery replacement or measurement ie settings other than selected or if the meter does not respond when a button is pressed remove the batteries wait at least 10 seconds and then re install them 11 3 Basic Operation Methods __ 3 Basic Operation Methods 34 Basic Operation Flow The basic operations and screens are as follows Measurements and measurement changes are operated from the Measurement screen Opening Screen Language Selection for first time only Make sure the Light Selection Dark Calibration Rin
108. perature Measurement Screen Target CCT Screen T 1 125 Target CCT Film FE 2500 10000K Target 5000K CCT 5000K DEL Hix Cancel If you are not using LB index filter and CC index filter values you can omit this step You cannot set the target color temperature using the CRI or Multi Lights Mode 63 5 Measuring Light Sources Measurement Screen 6 Touch the T Shutter Speed indication on the Measurement screen Set the shutter speed used for measurements gt P24 Match the blue background with the desired shutter speed Measurement Screen Shutter Speed Display Screen Bie Ea T 1 125 Target 5000K F2 Target 5000K COT Hix Shutter Speed Screen Shutter Speed The selected value is indicated by the blue background OK Button Cancel Cancel Button y noT E _ ii _ Select a shutter speed range that will synchronize with your camera and flash system 64 5 Measuring Light Sources Measurement Screen C Note If necessary you can select a previously created Preset value from Preset Selection in the Tool Box gt P146 Tool Box Screen Preset Selection Screen Tool Box Screen Digital Film Digital Film p Preset Selection Digital g Preset Selection Digital amp gp Preset Selection Film g Preset Selection Fi Im p Memory Title g ___ Not Selected A Memory Title
109. playing in Text Text Mode Selected 5 items are displayed in text Text Screen Target Indication Measuring Mode Icon Target 5000K Ea Display Mode Icon Text Display CCT Display Item Indication Lux CCi LBi Ra 1 Touch the Text icon on the Display Mode screen A Text screen will be displayed P29 2 Touch the Measuring Mode icon The Measuring Mode Selection screen will be displayed Select the desired measuring mode to use P22 3 Touch the Target indication Target 5000K Target CCT Input screen will be displayed P26 Set the desired color temperature number 33 4 Setting the Measuring Conditions 4 Touch the Display Item indication to change The Display item library screen will be displayed The currently selected display item will be encircled in blue 5 Touch the desired Display Item indication and OK button Confirms the settings and returns to the Measurement screen To return to the Measurement screen without changing touch the Cancel button Display Item Library Display Item Library Display Item Library in Ambient Light Mode in Flash Light Mode In Both Modes Text Screen Page 1 Page 1 Page 2 Ez Ez son E 5000K 5000K 5000K 5000K Target Target Target Target CCT Auv CCi CCo MB CCT Auv CCi CCe R1 R2 R3 LBi LBct LBt CC LBi LBct LBtr R5 R6 R7 fc Hix Hf R9 Lux CCi LBi Ra Cancel Cancel Cancel Touch Display Item indicatio
110. r jurisdictions e Adobe Reader is a registered trademark of Adobe Systems Inc e Rosco Cinegel and E Colour are a registered trademarks of Rosco Laboratories Inc e LEE is a registered trade mark of Lee Filters a division of Panavision Europe Ltd e Kodak and Wratten are trademarks of Eastman Kodak Company e Fujifilm is a registered trademark of Fujifilm Corporation e All other company or product names are trademarks or registered trademarks of the respective companies 2014 2015 SEKONIC CORPORATION All Rights Reserved E Safety Precautions Before using this product please read this Safety Precautions for proper operation The WARNING symbol indicates the possibility of death or serious injury if the product is not used properly A CAUTION The CAUTION symbol indicates the possibility of minor to moderate personal injury or product damage if the product is not used properly The NOTICE symbol indicates cautions or restrictions when using the product Please read all notes to avoid errors in operation The reference symbol indicates additional information about the controls or related functions Reading these is recommended The arrow indicates reference pages A WARNING e Infants or toddlers may accidentally wrap the strap around their neck so please place it in a location out of their reach There is a danger of suffocation e Do not place batteries in open flames attempt to short disassemble or appl
111. rd or when wireless measuring is desired In this measuring mode the meter will go into measurement standby mode for 90 seconds to wait for a burst of flash to measure 1 Touch the Tool Box icon Touch and select the Digital Film button P90 Tool Box Icon on the Measurement Screen Tool Box Screen 3 gi Target 5000K Ey P RETS Im The set Col contentis displayed Hix i p Memory Title CCi LBi p Radio Channel Zone a Ra 2 Select the type of camera Digital or Film used Touch either the Digital or Film button Digital Film Screen Jams uO Digital Omg Digital Film The selected icon will be displayed encircled in blue OK Button Cancel Button 62 5 Measuring Light Sources Measurement Screen 3 Touch the OK button Confirm and return to the Measurement screen To return to the Measurement screen without confirming touch the Cancel button 4 On the Measurement screen touch the Measuring Mode icon and select the Cordless Flash Mode icon on the next screen Select the measuring mode P22 Measuring Mode Measurement Screen Measurement Screen Selection Screen a Measuring Mode T 1 125 l eu Target 5000K Target 5000K Ambient Mode CCT CCT Cordless Flash Mode Lux Hix Cord PC Flash Mode CCi Radio Triggering Mode LBi Ra ya 5 Touch the Target indication Target CCT screen will be displayed P26 Set the color tem
112. s can be input 1 Touch the Edit User Information button on the Hardware Setting screen The Edit User Information Input screen is displayed Hardware Setting Edit User Information Screen Input Screen Hardware Setting Edit User Information f Adjust Touch Pane al Edit User Information Unnamed_ oS Factory Setting 171 8 Hardware Setting Screen _ 2 Edit the user information P19 Edit User Information Input Screen Edit User Information Edit User Information Unnamed_ Studio 1_ DEL Cancel Cancel OK Button Cancel Button 3 Touch the OK button Registers the user information and returns to the Hardware Setting screen To return to the Hardware Setting screen without registering the user information touch the Cancel button Hardware Setting Screen Hardware Setting 6 Adjust Touch Panel A Edit User Information The set content is displayed Factory Setting The user information is input 172 8 Hardware Setting Screen Factory Setting Return all display and setting contents of the meter to the factory default Factory Setting Screen Factory Setting Reset to factory default settings Are you sure 1 Touch the Factory Setting button on the Hardware Setting screen The screen of Reset to factory default settings Are you sure will be displayed Hardware Setting Screen Factory Setting Screen Hardware Setting Factory Settin
113. s the selected average CRI RA or individual CRI R1 R15 Each CRI is displayed in a bar graph gt P43 Displays correction values and camera filter names required to adjust measured source to Target Color temperature P45 Displays correction values and light source filter names required to adjust measured source to Target Color temperature P47 Displays the difference between the current measurement value and the reference color temperature in a white balance graph P53 The contents of Memory Recall Mode display the selected display items in the current Measurement Screen instead of display items at the time when memorized 102 6 Measurement Tool Tool Box Screen 1 Touch the Display Mode icon on the Memory Recall Mode Display modes of Memory Recall Mode will be displayed Memory Recall Mode Spectrum Screen Display Mode Selection Screen Display Mode Icon Target CC0256 Auv 01 29 89 3 Memory Recall Close Button 2 Touch the desired Display Mode icon to display Switches to each display mode screen 3 Touch the Close button Returns to the Measurement screen 103 6 Measurement Tool Tool Box Screen 6 3 3 Deleting Saved Measurement Results Memory Clear You can delete memorized measurement values individually or all at once In Memory Clear titles and memory contents memory numbers and measurement values are displayed in the re
114. selectable from about 20second about 40second about 60second none e 1 4 inch 20 threads e FCC amp IC CH1to16 344 04MHz CH17 to 32 346 5 354 0MHz e CE CH1 to 16 433 62MHz CH17 to 32 434 22MHz e FCC amp IC CH1to4 344 to 346 0MHz CH5 to 20 341 5 to 351 0MHz e CE CH1 t03 433 42 434 42MHz e 4 3 inch QVGA 480x800 dots e 1 5V x2 alkaline manganese e 5V 500mA or less via USB cable when connected to computer 185 Operating temperature e 10 C 40 C without condensation Operating humidity e 85 RH or less at 35 C without condensation Transportation and storage conditions e 10 C 60 C without condensation Dimensions e Approx 73 width x 183 height x 27 depth mm excluding protruding part of light receiving max thickness 40mm Weight e C 700 approx 230g without batteries e C 700R approx 238g without batteries Included accessories 9 Appendix __ e CD ROM this Operating Manual and applications Win amp Mac Soft case Strap Start up Guide Safety Precaution Specifications and appearance described in this Operating Manual are subject to change without prior notice for improvements 186 9 Appendix _ 9 4 Legal Requirement E Legal Requirement This product complies with the following legal requirements Destination Standard Details C Wireless R amp TTE Directive 1999 5 EC EN300 220 2 V2 4 1 2012 05 EN301 489 1 V1 9
115. t Auto Dimmer OE lit Ly Language it Radio System Preference a Reset Customized Items v A Close Cancel 141 7 Meter Settings Setting Screen e 2 Touch the desired language to use Select English Japanese or Chinese Language Screen Engl ish English sida The selected hi SE ON button will be displayed encircled in blue Cancel Cancel OK Button Cancel Button 3 Touch the OK button Confirms the settings and returns to Setting To return to Setting without confirming touch the Cancel button Setting Screen Bo AND bh WYHAT IL Op O DRS Oa Bay 23514 ORS Oa Bia 75 4 h ORATS EEE Be The set content is displayed Be Beara Do 22974 RAADEME h A The language is set 142 7 Meter Settings Setting Screen e 7 2 1413 Selecting the Radio System Preference C 700R Only Select from ControlTL Standard ControlTL Standard or Not in Use as the preference of the Radio Triggering Flash Mode ControlTL Standard is default setting Radio System Preference Screen ControlTL SEULE ControlTL Standard Default Not in Use Cancel 1 Touch the item Radio System Preference button on page 2 of Setting The radio system preference type and the Not in Use screen will be displayed Setting Screen Radio System Preference Screen ry ControlTL Ht Spectrum Y axis Scale t Auto Power Off Standard Xo Back ight Brightness
116. t Editing screen To return to the Preset Editing screen without confirming touch the Cancel button Preset Editing Digital Screen Preset No See eee List ESEN Target CCT LB Index Correction Value CC Index Correction Value The Preset Selection List is set 150 7 Meter Settings 7 3 2 Setting the Present Name Edit the preset name Preset Name Screen Default DQ1_ DEL Cancel Up to 16 alohanumeric characters can be input for Preset name 1 Touch the Preset Name button The Preset Name Input screen is displayed Preset Editing Digital Screen Preset Name Screen Preset No Preset Selection List Default D01_ Preset Name Target CCT LB Index Correction Value 1 A a CC Index Correction Value Cancel 151 Setting Screen __ 7 Meter Settings Setting Screen e 2 Use the keyboard to create a name for preset P19 Preset Name Screen Cancel OK Button Cancel Button 3 Touch the OK button The Preset name is fixed and returns to Preset Editing screen To return to the Preset Editing screen without confirming registering editing touch the Cancel button Preset Editing Digital Screen Preset No Preset Selection List Preset Name Target CCT LB Index Correction Value CC Index Correction Value The preset name is set 152 7 Meter Settings Setting Screen e 7 3 3 Setting the Preset
117. t the light when used in Cordless Flash Mode Be sure to take 5 4 Measurement in Cord PC Flash Mode P68 e When using Cordless Flash Mode the LCD screen backlight dims during measurement and the LCD backlight is illuminated for only 3 seconds after measurement To cancel standby mode touch the screen or press the Menu Button x3 _ _ e When using the meter in Cordless Flash Mode it is possible to mount the meter to a light stand tripod or similar support using the Tripod Socket e Over or Under will be displayed if the light source illumination is too bright or not bright enough or if the color temperature is out of the measurement range when the Measuring Button is pressed In this case adjust the brightness or color temperature of light source or switch the light range gt P88 67 5 Measuring Light Sources Measurement Screen 5 Measurement in Cord PC Flash Mode Cord PC Flash Mode is preferable when lighting conditions prevent the use of cordless measurements or when certain types of equipment require a physical sync connection In Cord PC Flash Mode the meter and flash unit are connected with a Sync Cord sold separately A CAUTION e Do not handle this product with wet hands or leave it in the rain or ina location where it may be splashed with water submerged or come into contact with moisture There is a danger of electric shock in Cord PC Flas
118. tes which icons are operational Touch enabled Icons Touch disabled Icons Slide Operation Slide your finger tip up or down over a value to change the value amount Sliding your finger over scroll bar provides fast navigation of large menus Ex Shutter Speed Selection Screen Top Icon Touch to advance to the lowest value Scroll Selection Slide a finger up or down on the setting value areas to change setting values Scroll Bar Touch and slide up or down to scroll settings Bottom Icon Touch to advance to the highest value One Step Icon Touch the Up or Down icon to advance one position Blue bar indicates the value selected 18 3 Basic Operation Methods __ 3 2 3 Input of Numbers Characters You can input numbers and characters Numeric Number Input Screen Ex Target Color Temperature Digital Display Target CCT Digital 2500 10000K 5000K gt m 27 DEL Cancel 4 Numeric Number Method Description ae Value displayed on screen when key touched delete Deletes input value at cursor position afo Confirms input value and returns to previous screen Cancel Cancels inputting and returns to previous screen 19 3 Basic Operation Methods __ Character Input Screen Number Input Screen Upper Case Input Screen Lower Case Input Screen Default DQ 1 _ Default DQ 1 _ 8 19 9 DEL DEL gt Default D01_
119. the item Product Information button on page 3 of Setting The Product Information screen will be displayed Product Information Setting Screen Screen Mode Name o Preset Editing Digital s Preset Editing Film Serial Number rear F W Version Me Dark Calibration User Information y Product Information Radio Regulation My Regulation Close Button 2 Touch the Close button Returns to Setting 164 7 Meter Settings Setting Screen 7 5 1 Regulation Display The Regulation screen displays the symbols approved number regulation names etc which the meter is compliance with Regulation Screen for C 700 Regulation Screen for C 700R 1 Touch the item Regulation button on page 3 of Setting The Regulation screen will be displayed The display contents will differ depending on the product you have purchased Setting Screen Regulation Screen for C 700 Mx Preset Editing Film Mx Dark Calibration pl mi a M Product Information Me Regulation 2 Touch the Close button Returns to Setting 165 8 Hardware Setting Screen __ 8 Hardware Setting Screen You can set the follow on the Hardware Setting screen e Adjust Touch Panel e Edit User Information e Factory Setting Hardware Setting Screen Hardware Setting fi Adjust Touch Panel A Edit User Information fi Factory Setting Item Name Description Adjust Touch Panel Adjust the p
120. tion modes show the standard value only even if Contrast Function is activated Measuring Button 1 Press the Measuring Button and start measurements The measurement results will be displayed Measurement Screen Target 5000K CCT Lux GGi LBi Ra Measurements and display will take longer in light levels below 30Ix The LCD illumination will normally switch off during measurements to avoid influence to measurements 84 5 Measuring Light Sources Measurement Screen 2 Touch the Delta ME icon The measurement results right before touching the icon will become the standard values The Delta icon will change 1o Target 5000K Target 5000K CCT HHI Lux Lux CCi CCi LBi LBi Ra Ra Delta Icon r EA 3 Press the Measuring Button While the Delta icon is change a the difference with the standard value is displayed as long as the Measuring Button O is pressed 5000K Ea CCT 4 160 Target Lux A 2411x CGi LBi Ra 4 Monitoring Function is complete When the Measuring Button O is released the standard value is displayed 5 Touch the Delta __4 __ icon The Delta icon will be deactivated i Cor e f the Delta icon ay is touched before a first measurement is taken Monitoring Function cannot be activated e The Delta icon a is deactivated when the power is turned OFF e When the Delta icon is displayed the Memory Bu
121. to select the range When measuring ambient light make sure to select Range L lo When measuring flash units select Range L le or Range H 1o depending on the brightness of of the flash gt P86 gt P88 Measuring Button Measurement screen 5000K Fa CCT 5587K Target Target 5000K CCT Measurement Lux Lux 7941x CCi CCi LBi Ra A 5 Press Memory Button to memorize light source values and link the reading to the created title name Memory Button 97 6 Measurement Tool Tool Box Screen 6 3 2 Recalling Measurement Results Memory Recall Screen The Memory Recall screen enables selecting a specific Title and any memorized measurement under the Title It allows viewing all memorized stored measurements for inspection All measurement screens can be viewed for each Memory number Memory Recall Screen Title Memory Cancel 98 6 Measurement Tool Tool Box Screen 1 Touch the Memory Recall button in the Tool Box Title and Memory will be displayed 2 Select the Title and Memory to recall with the blue background positions Tool Box Screen Memory Recall Screen Memory Recal p Digital Film Title py Preset Selection Digital 5 Move Title and P Preset Selection Film mlmm D then Memory p Memory Title number into Memory Clear the blue EEN A background Memory Recal
122. trum Comp screen T Select the desired memory data to compare the spectrum When a title is selected the memory linked to the title will be displayed Select memories to compare To select a title and a memory match them with the blue background positions Spectrum Comparison Title Memory Screen Spectrum Comp Title 02 LED NO 03 LED NO 3 Title Area Memory Area Displays linked data with the title OK Button Cancel Cancel Button 8 Touch the OK button Confirms the setting and returns to the Spectrum Comp screen To cancel the setting touch the Cancel button 9 The titles and measurements of the selected memories will be displayed on the Spectrum Comp screen Memory Title Display LED NO 4 05 Memory Title CCT 4331K Auv 0 0093 Memorized Measurement Value 40 4 Setting the Measuring Conditions 10 Line graphs will be displayed in the spectrum graph To select show hide the line graph use the Line Graph Display ON OFF check box Check the check box M to show Uncheck the check box O to hide Spectrum Comp Screen Target 5000K Current Measurement CCT 5587K duv 0 0129 LED NO 4 05 z cet 4331K 4uy 0 0093 Line Graph Display ON OFF LED NO 4 04 Check Box CCT 3079K Auv 0 0007 i Line Graph 0 2 11 Touch the Magnifying Glass icon The spectrum comparison graph will be enlarged The enlarged graph is displayed on the whole screen landsc
123. tton is disabled 85 5 Measuring Light Sources Measurement Screen When Over Under or Out of Display is Displayed When Over or Under is displayed measurement cannot be taken When Out of Display is displayed the indicated value is out of display while measurement can be taken 5 7 1 Display of Over Under or Out of Display When Over is displayed If the indicated values are higher than the maximum measuring range Over is displayed Light Selection Ring When measuring ambient light decrease the brightness of the illumination When measuring flash light turn the Light Selection Ring and change the range from L to H or lower the flash output power When Under is displayed If the indicated values are lower than the minimum measuring range Under is displayed When measuring ambient light increase the brightness of the illumination When measuring flash light turn the Light Selection Ring Measuring Button and change the range from H to L or raise the flash output power When Out of Display is displayed If Out of display appears in the filter number indication it is out of display range combination of filter number Take a new measurement after changing the target color temperature Measurements and display will take longer in light levels below 30Ix The LCD illumination will normally switch off during measurements to avoid influence to meas
124. ue Complies with JIS C1609 1 2006 general A class illuminometer 12MK Light source A 10001x 1 600K 40 000K 3 significant digits 1 600K 40 000K 3 significant digits 2 500K 10 000K 500 500MK Without decimal point 50 50daMK With decimal point 50 0 50 0daMK 184 e lluminance e Shutter speed e Flash light Other functions e Preset setting e Setting e Memory function e Memory clear recall function e Out of measurement range or out of display range e Battery capacity indicator display e Automatic power OFF function e LCD backlight e Touch panel lock function e Tripod socket Used radio frequency e Standard System e ControlTL System Display e LCD display resolution Recommended battery e AA batteries e USB bus power e Ambient light 9 Appendix _ 11x 200 000Ix 3 significant digits 0 1fc 18 600fc 3 significant digits in limited version only 1 second 1 500 second in 1 1 2 1 3 step plus 1 75 1 80 1 90 1 100 1 200 1 400 second e Preset 1 19 settings for each digital or film mode e 11 item settings C 700R 12 item settings possible e Up to 99 measurements or titles e Under Over Out of Display warning display e With 4 level status icons e Time elapsed after last operation selectable from 20min 10min 5min none e Brightness can be selected from bright normal or dark e Dimmer time after last operation
125. urement Display mode No 9 is for settings 2 Touch a desired Display Icon The measurement screen in selected Display Mode appears on the screen Display Mode Measurement Screen Selection Screen Text Mode Target Touch the CCT Text icon Spectrum Sorp omp a f Lux i a Camera Lighting CCi Filter Filter LBi tz WB Corr Setting Ra A 3 Press the Measuring Button to measure Light Selection Ring Turn the Light Selection Ring to select the range When measuring ambient light make sure to select Range L le When measuring flash units select Range L le or Light Range H 1o depending on the brightness of of the Receptor flash gt P86 P88 Measurements can now be made Measuring Button e To measure the color temperature of a light source properly point Light Receptor directly at light source during reading e Measurements and display will take longer in light levels below 30Ix The LCD illumination will normally switch off during measurements to avoid influence to measurements 31 4 Setting the Measuring Conditions 4 Observe measurement values on Text Mode Measurement Screen Text Mode Target 5000K CCT Lux CCi Measurement result LBi Ra 5 Memorize the measurement results Measurement results can be memorized To record measurements press Memory Button P95 32 4 Setting the Measuring Conditions 4 3 1 Dis
126. urements 86 5 Measuring Light Sources Measurement Screen xy _ Display range Color Temperature Digital Film Film C 700 C 700R 1 600K 40 000K 500 to 500MK LB Index LB Filter Numbers Camera Filter Kodak WRATTEN 2 LEE FUJIFILM LBA LBB Lighting Filter LEE ROSCO CINEGEL ROSCO E COLOUR CC Index CC Filter Numbers Camera Filter Kodak WRATTEN 2 LEE FUJIFILM CC Lighting Filter LEE ROSCO CINEGEL ROSCO E COLOUR Illuminance lux Exposure lux second Illuminance foot candle Exposure foot candle second Digital C 700 C 700R 1 600K 40 000K 80A 80B to 85B 85 LBB 20 LBB 16 to LBA 20 LBA 16 L287 DOUBLE CTO L204 FULL CTO to L200 DOUBLE CTB L283 1 5 CTB R3420 DOUBLE CTO R3407 FULL CTO to R3220 DOUBLE CTB R3202 FULL CTB E287 DOUBLE CTO E204 FULL CTO to E200 DOUBLE CTB E283 1 5 CTB 80G to 80M 200G to 200M CC50M CC40M to CC50G CC40G CC 50M CC 40M to CC 50G CC 40G L247 MINUS GREEN L248 1 2 MINUS GREEN to L244 PLUS GREEN L245 1 2 PLUS GREEN R3308 MINUS GREEN R3309 3 4 MINUS GREEN to R3304 PLUS GREEN R3315 1 2 PLUS GREEN E247 MINUS GREEN E248 1 2 MINUS GREEN to E244 PLUS GREEN E245 1 2 PLUS GREEN 11x 200 000Ix 20Ix s 20 500Ix s 0 1FC 18 600FC 1 86fc s 1 902fc s 8 5 Measuring Light Sources Measurement Screen 5 7 2 Changing t
127. ures of the C 700 C 700R Model name Usage Features C 700 Lighting control Controls ambient lights flash lights and environment for still and lights at shooting and controls light sources as devices motion capture Correlated color temperature Digital mode Photographic color temperature Film mode 1 600K 40 000kK e lluminance measurement e Displayed in accordance with usage 1 Color temperature 2 LB CC filter number KODAK WRATTEN 2 LEE FUJIFILM ROSCO 3 LB CC index 4 CRI measurements 5 Spectral distribution graph display graph display enlargement function 6 Illuminance luminous exposure ambient light flash light 7 Color deviation Auv e White balance function Lighting control e Radio transmission function to trigger PocketWizard for still and Brand radios using 340 354Mhz FCC models or motion capture 433MHz CE models x3 __ The C 70OOR is designed so that it complies with technical standards for human body absorption of electromagnetic waves established by the Japanese government 1 and electromagnetic wave protection tolerance that the international guideline recommends These international guidelines were established by the International Commission on Non lonizing Radiation Protection ICNIRP in cooperation with the World Health Organization WHO The tolerance includes a sufficient safety margin regardless of the user s age or health conditions
128. y heat to them use unspecified batteries or recharge them except rechargeable batteries They may burst and cause fires serious injury or damage to the environment A CAUTION e Do not handle this product with wet hands or leave it in the rain or in a location where it may be splashed with water submerged or come into contact with moisture There is a danger of electric shock if the Flash Light Cord PC Mode is used This may also result in damage to the product e Do not attempt to disassemble the product for modification or parts replacement It may affect measurement results or damage the meter e Do not attempt to play the included CD ROM using an audio CD player It may impair hearing or damage speakers and earphones e When controlling the meter with the LCD gently touch with your finger Using pointed pens or pencils may scratch the LCD screen or damage the product e Infants or toddlers may accidentally grab the strap and swing the product so please place it in a location out of their reach as the meter may be damaged by impacts e Be careful that the neck strap does not come loose when carrying the product as the meter may be damaged when dropped e This neck strap is made of polyester fiber Please refrain from using the product if synthetic fibers cause your skin to become irritated inflamed or itchy in order to prevent worsening your symptoms G nore e A protective sheet is attached to the LCD Peel it o
129. y terminals dirty Wipe them off with a dry cloth Are you using the specified Check the batteries P4 batteries The LCD does not Is the screen locked Press and hold the Menu respond Button O to unlock the screen P21 The measurement cannot Are you using the C 700 Series Stop using the C 700 Series be made Utility Utility The measured values are Is the Light Selection Ring in Rotate the Light Selection Ring wrong the middle position The light until it clicks distribution characteristics change and suitable measurements cannot be made Are any unnecessary corrections Check the Target reference or filter corrections set color temperature to see if the setting is wrong P26 Check the Preset Target Color Temperature and confirm the setting is correct P153 Is the measuring mode wrong Check if the measuring mode is Such as measuring in Ambient correct P22 Light Mode in flash light Are you using the pre flash In Cordless Flash Mode the function when measuring in measurement value of the main Cordless Flash Mode flash may not be displayed because the pre flash is measured at first Cancel the pre flash function 189 Status Setting values and measurement values of the spectrometer are not in the camera settings The memory function cannot be used Flash cannot be triggered in Radio Triggering Flash Mode C 700R only Check item Do the shutter speed and iris settin
130. yed Setting Screen Unit of illuminance Screen EETA Ix lxs fe fe s Shutter Speed Step Oy LB Step ELIES Camera Filter Brand a Lighting Filter Brand fc fes a White Balance Step Unit of I luminance Cancel 131 7 Meter Settings Setting Screen e 2 Touch the desired unit to use Select the unit of illuminance Unit of illuminance Screen Ix lxs fe fc s Ix xs c fe s Ix 1xs Ix 1x s The selected button will encircled in blue Cancel Cancel OK Button Cancel Button 3 Touch the OK button Confirms the settings and returns to Setting To return to Setting without confirming touch the Cancel button Setting Screen Be Shutter Speed Step y LB Step a Camera Filter Brand Lighting Filter Brand White Balance Step a Unit of I luminance The set content is displayed The unit of illuminance is set 132 7 Meter Settings Setting Screen e 7 2 8 Selecting the Spectrum Y axis Scale Select relative auto or spectral radiant intensity as the maximum display value for the spectrum y axis Spectrum Y axis Scale Screen Default 1 Touch the item Spectrum Y axis Scale button on page 2 of Setting The maximum display value of the spectrum y axis scale will be displayed Setting Screen Spectrum Y axis Scale Screen a Spectrum Y axis Scale it Auto Power Off Xo Backlight Brightness Xt Auto Di