1.                 Head these safety warnings and instructions      thismanual completely  beforeinstallation and start up of the pump lt is the user s responsibility to  retain this manual Any operation performed that is not in according to the information provided under the manual may render the pump s warranty  invalid     WARNINGS    WARNING  Check all the connections with gaskets  for any looseness before operating the pump  Any  loose connection must be tightened to prevent any  leakage    WARNING  Check all capscrews and ring nuts for    ghtness before operating the pump for the first  time     WARNING  Lubricate the pump continuously with  the conditioner  In order to prevent effluent water  from the air line       addition to usage of the  conditioner  discharge the water accumulated in the  compressor tank     WARNING  Operate the pump with a conditioner    installed at in front of the pump     WARNING  Be sure not to tighten excessively to the  capscrews during the assembly and disassembly   otherwise the pump s main body may be damaged     WARNING  The silencer must be used while  operating the pump        HP 20 METALLIC PUMP Pagel6       HP 20 METALLIC PUMP USER S MANUAL    WARNING  Please be careful at the pump transfer     WARNING  The pump should be installed onto the  rubber mountings     WARNING  Take action to prevent static sparking   Fire or explosion can result  especially when handling  flammable liquids  The pump  piping  valves   containers or other misc
2.    VP 20 METALLIC PUMP USER S MANUAL V E STA pump    USER MANUAL  VP 20 PLASTIC  METAL PUMPS    VP 20 METALLIC PUMP USER S MANUAL VESIA PUMP    COMPRESSED AIR DOUBLE DIAPHRAGM  TRANSFER PUMPS    TABLE OF CONTENT    PUMP PERFORMANCE CURVES 2 AIR INLET AND PRIMING 13  DIMENSIONS 3 FREQUENCY OF USE 14  PACKAGING 4 TROUBLESHOOTING 14  DIAPHRAGM MATERIALS 5 WARNINGS 15  SPARE PARTS DRAWINGS 6 PUMPING HAZARDOUS LIQUIDS 17  SPARE PARTS LIST 7 AIR VALVE ASSEMBLY 18  PRINCIPLE OF PUMP OPERATION 9 AIR VALVE MAINTENANCE 19  INSTALLATION  amp START UP 9 PILOT VALVE ASSEMBLY 20  AREAS OF APPLICATION 11 PILOT VALVE MAINTENANCE 21  AIR CONNECTION 13 DIAPHRAGM MAINTENANCE 22  AIR VALVE LUBRICATION 13 INTERMEDIATE ASSEMBLY MAINTENANCE 24  AIR LINE MOISTURE 13 CHECK VALVE MAINTENANCE 25    PERFORMANCE CURVES  MODEL HP 20 METALLIC PUMP Page 2    VP 20 METALLIC PUMP USER S MANUAL VE O   A PUMP    Makes life comfortable      bar  10 m3 h  hava giris debisi                       67 m3 h          Pump Head                                                 0 20 40 60 80 100 120 140 160                       Volumetric Capacity   LPM             The operation pressure is O to 7 bars   Operation temperature is between   18          100         METRIC DIMENSIONS   mm    Dimensional tolerances   3 mm  MODEL HP 20 METALLIC PUMP Page 3    VP 20 METALLIC PUMP USER S MANUAL VE 5   A PUMP    Makes life comfortable    z CIKIS HATTI             2  GIRIS HATI                      3 4           G  R          A B C
3.   CM16X60  5  10     5  10  RM10 P    VES      pam    Pin Bushing   Cover  Air Inlet Assembly  Gasket  Air Valve   Gasket  Pilot Valve  Front  Gasket  Pilot Valve  Rear  Gasket  Inner Chamber  O ring  Pin   Inner Diaphragm Holder  Outer Diaphragm Holder  Outer Diaphragm Holder  Outer Diaphragm Holder  Actuator Pin   Diaphragm Rod   Oil Seal   Muffler   Washer  M8   Washer  M8   Washer  M10   Washer  M10   Capscrew M 10 X60 imbus  Capscrew M 10 X 60 imbus  Capscrew M 8 X 45  Capscrew M 8 X 45  Capscrew M 10 X 60  Capscrew M 10 X 60  Capscrew M 10 X 50  Capscrew M 10 X 50  Capscrew M 10 X 30 imbus  Capscrew M 10 X 30 imbus  Capscrew M 16 X 60  Capscrew M 16 X 60   Ring Nut  M10   Ring Nut  M10   Nut  Hex M10    PFPA AR p          LIS     D N Q        I    HP 20 METALLIC PUMP USER S MANUAL    35 5  10       5  10       MATERIAL CODES    30 ALUMINUM  31 CAST IRON  32 STAINLESS STEEL  33 POLYPROPYLENE    34 DELRIN   35 PVDF   36 POLYETHYLENE  38 BRONZE   HP 20 METALLIC PUMP    Ring Nut  Flanged 16  Ring Nut  Flanged 16  45 NEOPRENE  46 SANTOPRENE  47 BUNA N  48 EPDM  50 TEFLON  51 VITON  70 DIA SPECIAL MATERIAL    STEEL    VES Arun    Page9    HP 20 METALLIC PUMP USER S MANUAL    PRINCIPLE OF PUMP OPERATION    The diaphragm pump is consisted of two diaphragm chambers and  two diaphragms The diaphragms are connected to each other with a  diaphragm rod andmove in a reciprocating action As one diaphragm  performs thedischarge stroke  the other diaphragm which is  connected with the r
4.  USER S MANUAL V E                     Makes life comfortable       COMPOSITE PARTS LIST    HP 20 METALLIC PUMP Page7    HP 20 METALLIC PUMP USER S MANUAL    1    9  10  11    HP 20 METALLIC PUMP    5012030  5012031  5012032  5022030  5022031  5022032    016030    016033    022030    022033  5032030  5032031  5032032  5042045  5042046  5042047  5042048  5042050  5042051  5052036  5052045  5052046  5052047  5052048  5052050  5052051  5062045  5062046  5062047  5062048  5062050  5062051    034033    044033  H055047  RM10    Suction Line  Suction Line  Suction Line  Discharge Line  Discharge Line  Discharge Line  Main Body  Main Body  Inner Chamber  Inner Chamber  Outer Chamber  Outer Chamber  Outer Chamber  Check Ball  Check Ball  Check Ball  Check Ball  Check Ball  Check Ball  Check Ball Seat  Check Ball Seat  Check Ball Seat  Check Ball Seat  Check Ball Seat  Check Ball Seat  Check Ball Seat  Diaphragm  Diaphragm  Diaphragm  Diaphragm  Diaphragm  Diaphragm    Air Valve Repair Kit  Pilot Valve Repair Kit    Bumper  Nut  Hex M10         N         J I I   NN  N NN                           FS NS      N                                    27    28    29    30    31    32    33    34    H064034  H072033    084047    094047    104047    115047  H124047  H137030  5073030  5073031  5072032    145090    152090  H165047  H174036      8      PM8  PM10 P  PM10      10  60       CM10X60 I  CM8X45 P  CM8X45  CM10X60 P  CM10X60  CM10X55 P  CM10X55      10  30           CM10X30 IHB  CM16X60 P
5.  valve    Remove the snap rings of two plugs beneath the air valve with pliers  in order to have access to the internal parts of the air valve  Then  remove two caps Check O rings to see any abrasion or cuts Replace  O rings as needed Take the spool out of the sleeve  Be sure not to  scratch or damage the surface of the spool s mating surface Wipe the  spool with soft piece of cloth and check to see any scratch or  damage Check inner surface of the sleeve to see any dirt  scratches  or other contaminants Remove the sleeve and replace with a new  sleeve and spool assembly  as necessary     HP 20 METALLIC PUMP    VES      pume      Third  reassembly of the air valve    To do this  install one bumper together with its O ring on the one side  of the air valve assembly  Check O rings of the existing or new or  sleeve and spool set replaced as necessary Carefully take the spool  out from the sleeve Install six O rings into the six grooveson the  sleeve    Then install the liner onto the main housing of the air valve Be sure to  apply a light coating of grease to the O rings before installing  thesleeve into the valve body  alignthe slots in the sleeve with the  slots in thevalve body  Insert the spool into the sleeve Be careful not  to scratch or damage the spool during installation Install other  bumper together with its O ring  Install the snap ring  The repair of the  valve is completed During installing the complete with and gasket  onto the pump  be sure to have the holes of t
6. D E F G H I J             435   256  312  690  327 5  362 5   591   220  250  374  296          PACKING DIMENSIONS   mm      MODEL HP 20 METALLIC PUMP Page 4    VP 20 METALLIC PUMP USER S MANUAL VE 5      PUMP    Makes life comfortable       AB C  460  460          DIAPHRAGM MATERIALS AND OPERATION TEMPERATURES    MODEL HP 20 METALLIC PUMP Page 5    VP 20 METALLIC PUMP USER S MANUAL V E S TA pump    Lu ERR         Neoprene   It is resistant to the vegetable oils Its abrasion resistant is very   good  The fluids like acids  esters  ketones can cause damages 90 C  22 C  to the material of construction and therefore they are not   recommended     Buna N  It is generally used for oils It is very durable to the transfer of 87 C  22 C  water and hydraulic oil     EPDM  It is durable to chemicals lt is not durable to oil and solvents  It 138 C  40       has moderate resistance to the alcohols and ketones     Teflon   It is generally used for heavy chemicals and         5 1   features  good resistance lt is suitable for heat transfer at elevated  temperatures     Viton         It has very good resistance to acids  oils and solvents  Bes  Santopren   It is resistant to weak and medium acids  It features good 135 C  40 C  abrasion resistance        Polypropylene  It is resistant to chemicals It is usually preferred for food  82 C 0 C  chemicals and cosmetic products     COMPOSITE PARTS DRAWING OF HP 05  3 4     METALLIC PUMP       MODEL HP 20 METALLIC PUMP Page 6    HP 20 METALLIC PUMP
7. LLIC PUMP Page23    HP 20 METALLIC PUMP USER S MANUAL    For maintenance of diaphragms  first remove the suction line of the  pump and than block the pump discharge line Cut off the compressed  air supplybleed thepressure from the pump and disconnectthe air  supply line from the pump  Drainany remaining liquid from the  pump Inspect the pump assembly drawings and maintenance  diagrams Remove the manifolds Remove the pump ball and ball  seats  Then remove the outer covers of the pump      First  Removal of diaphragm assemblies    Use M16 wrench or socket to unscrew the outer diaphragm holder by  turning counterclockwise direction and remove the diaphragm  assembly from thediaphragmrod Then take onediaphragm together  with outer and inner diaphragm holders and the otherdiaphragm with  its diaphragm rod out In order to disassembly first diaphragm with its  holder  hold the diaphragm assembly with a vice by clamping the  inner holder and remove the outer holder by turning it  counterclockwise with M16 spanner     Hold the diaphragm rod of other diaphragm assembly with a vice and  dismantle diaphragm with a spanner Perform dismantling the other  diaphragm in the same manner Check the diaphragm for cuts   bursting  abrasion and chemical corrosion Replace the diaphragms  as necessary     HP 20 METALLIC PUMP    VES      pume     Second  Installing diaphragms    Insert M16 capscrews onto the outer diaphragm holder and push the  diaphragm into the center hole  Install the capscrews ont
8. ary to maintain the exhaust port of the pump  above the liquid surface with pipe or hose        Diaphragm pumps can be used to transfer  the fluid in the tank readily by connecting  them to the bottom of the tank        HP 20 METALLIC PUMP Page12    HP 20 METALLIC PUMP USER S MANUAL V E STA PUMP    Makes life comfortable    Diaphragm pumps can also be used as barrel pumps   They have effective suctions ability and able to transfer  all the fluid in the barrel        The diaphragm pumps are able to transfer fluids at 6 meter of deepness   Cavitation might obstruct the operation To prevent this  the air in the hose between  the pump and fluid should be discharged        HP 20 METALLIC PUMP Page13    HP 20 METALLIC PUMP USER S MANUAL    AIR CONNECTION    The air pressure should not be in excess 7 bars  The pump should be  provided with the air supply at such pressure and flow to achieve  desired performance When the airsupply line is solid piping  use a  short length of flexible hose not less than 7 in diameter between the  pumpand the piping to reduce strain to thepiping  The weight of the  air supply line  regulators and filters must be supportedby some  means other than the airinlet cap  Otherwise  unsupportive weight  may result in damageto the pump  A pressure regulatingvalve should  be installed to   insureair supply pressure does         exceedrecommended limits     WARNING If the size of air connection is  smaller than the pump supply port  the    pump will not be able t
9. ates under cavitation  In such cases  the  valveshould be closed slightly to obtain themost efficient air flow to  pump flowratio     Pagel4    HP 20 METALLIC PUMP USER S MANUAL    FREQUENCY OF USE    The pump should be flushed after each application to prevent its  damage if the pump is used for the transfer of the fluid that contains  suspended particles that settle and harden in the course of time when  it is kept stand still  Otherwise  product remaining in thepump  between uses could dry out orsettle out  This could cause  problemswith the diaphragms and check valvesat restart   The pump  should be completely drained after every use in particular under  freezing temperatures     PUMP PROBLEMS AND SOLUTIONS    PROBLEM  The pump fails to operate even the air is supplied The  supplied air is directly exit through the exhaust filter    SOLUTION  Check the air valve of the pump The piston of the liner   piston assembly of the air valve may be jammed Disassembly the air  valve thenremove  clean and lubricate the piston of the liner piston  assembly Wipe off and lubricate the liner Install the piston in the liner  and break in a while Install the air valve back and start the pump     PROBLEM  The pump operates but no flow is transferred   SOLUTION  Check the valves of the pump The valve plunger may be  jammed by the foreign matters In such case  no transfer of the fluid is  possible     HP 20 METALLIC PUMP    VES      Pump    PROBLEM  The pump is in operation  but the capacity 
10. ellaneous equipment must be  grounded     WARNING  The air supply should be switched off  before any repair or maintenance of the pump  Then  pump pressure should be released and air connection  be removed  Be carefulcompressed air line        HP 20 METALLIC PUMP    WARNING  The fittings should be installed to  eliminate any possible leakage of the transferred  liquid     WARNING  In order to prevent the knock at the  discharge  the pump should be complete with the  flexible hose adaptor at the discharge port where the  pipe assembly 15 long     WARNING  Be sure using the gloves and goggles  in the pump repair and maintenance works     WARNING  When used for toxic or aggressive  fluids  the pump should always be flushed with  water before the repairment     Pagel7       HP 20 METALLIC PUMP USER S MANUAL    WARNING  If the diaphragm is split then  the  transferred fluid may pass to the air side of the pump    and diffuse to the atmosphere If pumping a product  which is hazardous or toxic  the air exhaust must be  piped to an appropriate area for safe disposition        VES Arun    NOTE Contact to our company in case of any failure of the pump provided under the warranty 2 year warranty will be terminated if the pump is    dismantled without notifying to our company     PUMPING HAZARDOUS LIQUIDS    When a diaphragm fails  the pumpedliquid or fumes enter the air end  ofthe pump  Fumes may dissipate in the ambient air  Whenpumping  hazardous or toxic materials the exhaust air mus
11. firstthe  compressed air supply  bleed the pressure from the pump   anddisconnect the air supply line fromthe pump      First  Inspect pump installation drawings   Remove four capscrews by using   8 spanner or socket wrench   Remove the air inlet cap and air inlet gasket  The pilot valve  assembly can now beremoved      Second  Inspect actuator pins   See the assembly drawings Access to the actuator pins can be  reached through the opening of the pilot valve assembly  Remove the  plungers fromthe bushings in each end ofthe cavity  Inspect the    HP 20 METALLIC PUMP       VESTA pump    Makes life comfortable     18      42     installed o ring for cuts and or wear  Replace the o rings  if it s  necessary Lubricate O rings slightly and install the pins into the  bushing  Push the plungers in as far as they willgo        Third  Install the valve assembly into intermediate gap  During installing the pilot valve assembly onto the intermediate  portion  be sure pilot valve ends located to the center of the actuator  pins Install the gasket  air inlet cover and capscrews Connect the air  supply onto the pump  The pump is now ready for operation     Page25    HP 20 METALLIC PUMP USER S MANUAL  CHECK VALVE  BALL  amp  SEAT  MAINTENANCE    Shut off the suction line and discharge line of the pump before  starting the maintenance work Then shut the compressed air supply   discharge the pressure in the pipe and remove the compressed air  connection Discharge the fluid in the pump Now the 
12. he valve in line with the  holes on the pump Connect the compressed air line onto the  pump  The pump is now ready to operation     Page20    HP 20 METALLIC PUMP USER S MANUAL V E                     Makes life comfortable    PILOT VALVE ASSEMBLY   H044033      10 PART LIST OF PILOT VALVE REPAIR KIT    Item No  Part No  Name of Part Qty  10A H454033B Pilot Valve Body 1  10B H464090 oleeve 1  10   H474047              sleeve 6  10D H484090 Spool 1  10E H494047 O ring  Spool 3  10F 5124090 onap ring 1       HP 20 METALLIC PUMP Page21    HP 20 METALLIC PUMP USER S MANUAL    PILOT VALVE MAINTENANCE    To begin with the servicing of the air valve first shut off the  compressed air  bleed pressure from the pump  and disconnect the  air supply line from the pump      First  See pump assembly drawings    Remove four capscrews by using M8 spanner or socket wrench   Remove air inlet cover and air inlet port gasket The pilot valve  assembly may now be taken out for inspection and service      Second  Removal of the pilot valve    Remove the spool of the valve Wipe it to remove any dirt  Check the  spool and O ring to see any dirt  cut or abrasion Replace O ring and  spool as necessary Remove the snap ring from the end of the sleeve  and remove the sleeve from the valve body Wipe it to remove any  dirt  Check the sleeve and O ring to see any dirt  cut or  abrasion Replace O ring and liner  if needed     HP 20 METALLIC PUMP    VES      pume       Third  Installing the pilot valve   Genero
13. o inner  diaphragm holder and screw it onto the rod by turning clockwise Hold  loose assembly with a vice Screw M16 wrench with a spanner        Third  Installing diaphragm assembly onto pump    Make sure the bumper is installed over the diaphragm rod  Screw the  rod of the diaphragm assembly by turning clockwise into threaded  hole until it is in the same direction with the end of the inner  diaphragm plate  Insert rod into pump Bring the capscrew holes on  the diaphragm in line with inner chamber capscrew holes Install outer  chamber onto the pump by capscrews and ring nuts     On the opposite side of the pump pull the diaphragm rod out as far  aspossible  Make sure the second bumperis installed over the  diaphragm rod Screw the exposed part of the diaphragm assembly  shaft in clockwise direction onto the diaphragm rod as much as  possible and leave the gap sufficient enough to adjust the capscrew  holes on the diaphragm in line with inner casing capscrew holes     Install the part of outer casing onto the pump with capscrews  nuts  and washers  Install the manifolds onto the pump with capscrews   nuts and washers  Perform the necessary connections onto the  pump  Now the pump is ready for the operation     Page24    HP 20 METALLIC PUMP USER S MANUAL    THRUST PIN MAINTENANCE    Item No  Part No  Name of Part Qty  3 H015030 Main Body 1  21 H145090 Actuator Pin 2  18 H124047 O ring  Pin 2  12   064036 Pin Bushing 2       To begin with the maintenance of the actuator         
14. o provide the air  required so  it will not perform properly        AIR VALVE LUBRICATION    The air distribution valve and the pilot valve are designed to operate  without lubrication  This is the preferred modeof operation  In regard    HP 20 METALLIC PUMP    VES      pump    to anticipated practice or inferior air quality  it is likely include  lubrication oil into the compressed air  The pump air system will  operate withproperly lubricated compressed                     Proper  lubrication requires theuse of an airline lubricator system to deliver  one drop of SAE 10 oil for every 10 liters sec  of airconsumed by the  pump at the operation point For better determination of the mixing  ratios  see the performance curves provided for the pump     AIR LINE MOISTURE    Water in the compressed air supply might give rise to problem like  freezing of the water or icing in the discharge line thatcause the pump  to cycle erratically or stopoperating These problems might be  removed by using a point of use air dryer to supplement the user s  airdrying equipment         air drying equipment will removes the water  andalleviates problems like  freezing or icing     AIR INLET AND PRIMING    Before operating the pump  turn the air supply valve at about 1 2 or  3 4 of a turn Afterthe pump primes  the air valve can be opened to  increase air flow as desired   If opening of the valve increases of the  reciprocating frequency without increase in air flow  then it means  that the pump oper
15. od ispulled to perform the suction At the end of  the stroke  an airdistribution valve automatically shifts  reversing the  entire sequence  filling and pumping from alternate chambers  Mutual  movements that repeatedcontinuouslyensure suction and discharge  movements onto the fluids in each chamber Continuously repeated    INSTALLATION  amp START UP       HP 20 METALLIC PUMP              eem    VESTA PumP    Makes life comfortable    reciprocal motions pump the liquid during entering to andexitingfrom  the chambers The flow of the fluid from one chamber to another is  regulated by the suction and discharge valves     The ball and butterfly valves automatically controls the fluid suction  and discharge of the fluid  The butterfly valves allow passage of the  solid particles with a size up to diameter of the pipe  The ball valves  regulate passage of the small size particles        Pagel0    HP 20 METALLIC PUMP USER S MANUAL    The interconnections of the diaphragm pump are straightforward  The  fluid is taken from the bottom manifold and discharged at the upper  manifold Diaphragm pumps are characterized by turbulence flow        prevent turbulence flow  the flexible hoses are installed upstream the  suction and the discharge port     In order to observe the pressures at the suction and discharge parts  of the pump and adjust the flow rate the manometers and valves         attached at the suction and discharge ports  When one or both valves  are closed down  the pump will be 
16. of the fluid is  Insufficient    SOLUTION  There might be several reasons              pump suction and discharge port sizes are not proper In such  case  the air flow for the pump operation will be insufficient       he air flow is less than the required volumetric rate lt is likely that  the compressor falls short in supplying required air       he cross sectional area of the pump at the suction and discharge  ports might be contracted Any contraction of the pump s suction and  discharge ports might cause a drop in the real pump s capacity     PROBLEM  The pump transfers the fluid  but the flow is fluctuating   SOLUTION  Check the pilot valve and air valve of the pump    O rings of the piston of the pilot valve may be worn out If this is so   replace the pilot valve      The piston in the air valve might be worn out Disassemble the  piston and liner assembly of the air valve and lubricate before  reassembling If the problem still persists  than replace the assembly  completely     PROBLEM  There is excessive vibration in the pump during the fluid  transfer    SOLUTION  There might be several reasons and solutions for that      High exit pressure of the pump and lack of rubber mountings on the  pump s pedestals      Long discharge pipe and lack of compensators on the pipe installed  at specific intervals to prevent vibration      Use of flexible adaptors at the suction and discharge ports of the    pump    Pagel5    HP 20 METALLIC PUMP USER S MANUAL VESI                     
17. pump can be  disassembled for the maintenance     Hemove the manifold to have access to the check valves     Inspect the check balls for any abrasion  cuts or corrosion  marks Perform the same checks on the check valve seats to see any  cuts  abrasion and any foreign materials embedded onto the  surfaceof both the external and internal chambers The  sphericalsurface of the check balls must seat flush to the surface of  the check valveseats for the pump to operate to peak efficiency     WARNING  The air supply should be switched off  before any repair or maintenance of the pump  Then    pump pressure should be released        air  connection be removed  Be carefulcompressed air       line    Item No  Part       Name of Part Qty  2 5022030 Discharge Line 1   6 5042045 Check Ball Seat 4   1 5052045 Suction Line 1   7 5032030 Check Ball Seat 4   5 5012030 Outer Chamber 2  HP 20 METALLIC PUMP    The damaged or worn out  parts should be replaced as  necessary Re assemble the  parts of the check valves  The  seat should fit into thecounter  bore of the outer chamber   Assemble the pump         make necessary  connections  The pump is  ready for operation     VESTA pump    Makes life comfortable          Page26    
18. stopped When they are opened   the operation will be resumed     For the pump operation  the pressurized air is required  The pump is  operated at the full capacity  if the suction and discharge hoses are  the same size A conditioner should be installed at the suction  port  The conditioner will allow the pressure adjustment         lubricating the air direction valve The valve installed downstream the  air inlet line the air flow is regulated by the valve operation     HP 20 METALLIC PUMP    VES      pume    Special precautions should be observed in the operation of  diaphragm pump These precautions will provide the maximum  efficiency to the the pump        The pump should be located as close to the product being  pumped as possible        he suction line length and number of fittings should be kept in     minimum              size of the suction pipe should not less than the size of the  suction port of the pump    e For installations of rigid piping  short sections of flexible hose  should be installed between the pump and the piping    e  he flexible hose reduces vibration and strain to the pumping  system    e  he buffer tank should be provided at the discharge port of the  pump if discharge pipe assembly is long  The buffer tank will reduce  transfer of the vibration in the pipe assembly onto the pump     Pagell    VESTA Pump    HP 20 METALLIC PUMP USER S MANUAL listes      cnd    AREAS OF APPLICATION    Diaphragm pumps can also be used as submerged pump   It is necess
19. t be piped to  anappropriate area for safe disposal     If the material of construction of the pump is compatible to the liquid  being pumped  the pump can be submerged into the fluid In such    HP 20 METALLIC PUMP    case the air exhaust must bepiped above the liquid level         size of  the pipe for air discharge should be at least 1  diameter Reducingthe  pipe size will reduce air flow and pump performance  If the liquid to be  transferred is at higher lever than the pump  flooded  suctioncondition   the discharge port should be kept at a higher level  then the liquid surface to prevent siphoning spills     Pagel8    HP 20 METALLIC PUMP USER S MANUAL V E                     Makes life comfortable    AIR VALVE ASSEMBLY   H034033    9 PART LIST OF AIR VALVE REPAIR KIT    Item No  Part No  Name of Part Qty  9A H554033B Air Valve Body 1  9B H564070 Sleeve and Spool Set 1  9   H574047 O ring 8  9D H584033 Cap 2  9E H504090 onap ring 2     8        HP 20 METALLIC PUMP Pagel9    HP 20 METALLIC PUMP USER S MANUAL  AIR VALVE MAINTENANCE    To begin with the servicing of the air valve first shut off  thecompressed air  bleed pressure from thepump  and disconnect the  air supply line from the pump       First  inspect the exploded view of the air valve    Remove four hex capscrews by using wrench or socket  Remove the  air valve assembly from the pump Remove the gasket and check to  see any cracking or damage Replace the gasket if it is necessary       Second Disassembly of the air
20. usly lubricate outside diameter of the sleeve and o rings   Then carefully insert sleeve into valve body During the installation of  the sleeve  takeCAUTION not to damage O rings Install the snap ring  to sleeve  Lubricate the other surface of the piston and O ring Then  carefully install the spool into the sleeve During the installation of the  piston  takeCAUTION not to damage O rings      Fourth  Re install the valve assembly into intermediate portion   During installing the pilot valve assembly onto the intermediate  portion  be sure pilot valve ends located to the center of the piston  pins Re install the gasket  air inlet capand capscrews  Connect the air  supplyto the pump  The pump is now ready for operation     Page22    HP 20 METALLIC PUMP USER S MANUAL V E S      PUMP    Makes life comfortable    DIAPHRAGM MAINTENANCE       Item No  Part No  Name of Part Qty     ot     19                 4   20   m     192     3 H015033 Main Body 1  23 H165047   Oil Seal   22 H152090 Diaphragm Rod   17 H137047 Gasket  Inner Chamber   4   022033 Inner Chamber   31 CM10X30 IHB Capscrew M 10 X 30 imbus  11 H056047 Bumper   19 H132030 Inner Diaphragm Holder   8 5062045 Diaphragm   20 5072030 Outer Diaphragm Holder  32   CM16X60  Capscrew M 16 X 50    2  1  2  2  2  2  1  2  2  2    Double diaphragms are used for the pump with Teflon  diaphragm  The rubber diaphragm which installed at    the front of the Teflon diaphragm provides  supports  and extends the service life        HP 20 META
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
Concours FAE 2001  Dataram DRI570/16GB memory module  Tanita Corporation  D D GB F NL S I E P DK  Instructions d`installation - Garantie Installation Instructions  CN-CVJM-K209 - 500X Microscope    GDADS Front-Office config file  Manuale d!istruzioni  Whirlpool 9700 Dishwasher User Manual    Copyright © All rights reserved. 