the IDR-210: ELF milligaussmeter PDF user manual
Contents
1. With HyperTerminal Transfer File Click Start At the RS232 command prompt log list Transfer running as described in the RS232 Configuration gt Capture Text x field measurement y field measurement z field measurement m field measurement Capturing Data with HyperTerminal section gt Capture Text ELFMeterLog txt in the HyperTerminal window type gt Stop Page 7 ELFMeterOperation txt Edit ELFMeterLog txt with a text editor WordPad etc to view the data or write a script to convert the data for post processing with MATLAB or Excel Page 8
2. Left Right or Enter to return to the log menu View Log Press Log Press Down four times Press Enter to view individual log entries Use the Up and Down buttons to move forward or backward one log entry Use the Right and Left buttons to move forward or backward ten log entries Press Enter to return to the log menu List Log Press Log Press Down five times or vi twice Press Enter to automatically list each log entry sequentially Press Up Down Left Right or Enter to return to the log menu Clear Log Press Log Press Down five six or Up once Press Enter to erase all the logged data RS232 Configuration Start gt Programs gt Accessories gt Communications gt HyperTermi na Connection Description Name ELF Meter Click OK Connect To Connect using COM1 Serial A COM2 Serial Port B Click OK COMx Properties Bits per second 9600 Data bits 8 U None Stop bits 1 Flow control Xon Xoff Click OK RS232 Command Set Page 3 ELFMeterOperation txt Notes lt bksp gt the backspace key in the upper right corner of a standard US keyboard lt enter gt the enter key All the RS232 commands are listed in double quotes which should not be included when iene the commands in HyperTerminal All commands must be followed by pressing lt enter gt Only lt bksp gt can be used for editing the commands while using the RS232 interface The arrow keys cannot be used and may lock up the interface When lt bksp gt
3. ELFMeterOperation txt ELF Meter 1DR 210 Buttons Layout Normal Range Up Log Left Enter Ri ght Maxi mum Down Shift Shifted Offset Reserved Reserved Frequency Reserved Channe Alarm Reserved Reserved Functions Up Down Left Right Menu navigation and changing options Enter Selects menu options Shift Switch to select secondary button functions S will be displayed in the lower right corner of the screen Range Selection Press Range Press Up or Down to select a range 200 mG 2000 mG or Auto Press Enter to switch to the selected range Press Left to exit without changing the range R will be displayed in the lower right corner of the screen while the meter is in the autoranging mode Channel Selection Shift gt Right Press Shift gt Right to switch to the next channel order x y z Current channel is displayed on the screen Frequency Display Shift gt Left Press Shift gt Left n switch to the frequency display mode Press Up Down Left Right or Enter to exit frequency display mode Maxi mum Press Maximum to change to the maximum reading mode Press ne Down Left Right or Enter to exit maximum mode M will be displayed in the lower right corner of the screen while the meter is in the maximum mode Offset Shift gt Range Press Shift gt Range to change to offset correction mode Press Up Down Left Right or Enter to exit offset correction mode Alarm Shi gt Maxi mum ift Press Sh
4. ift gt Maximumto enter the alarmthreshold mode Set the alarm threshold Use the Left and Right buttons to select a digit or the units and use the Up and Down buttons to change the value Press Enter to set the alarmthreshold and activate the alarm A will be displayed in the lower right corner of the screen while the alarmis activated Press Up Down Left Right or Enter to deactivate the alarm Page 1 ELFMeterOperation txt Press Log to enter the data logging menu Start Stop Logging Logging Interval submenu Log Style Full Single Logging Status View Log List Log Clear Log Use the Up and Down buttons to navigate through the menu Press Enter to select an option toggle an option or enter a submenu Press the Left button to exit the menu or submenus Start Stop Logging Future state is always displayed present state is opposite of display Press enter to switch to the new state Examples Meter is not logging data Press Log Start Logging is displayed Press Enter to start logging data Press Left to exit to the main display Meter is logging data Press Log Stop Logging is displayed Press Enter to stop logging data Press Left to exit to the main display L will be displayed in the lower right corner of the screen while he meter is logging data Logging Interval submenu Press Log to enter the data logging menu Press Down to navigate to the Logging Interval submenu Press Enter to enter the logging Interva
5. is pressed the cursor will move back one space but the previous character wil not be deleted Just type over the existing character to make corrections The RS232 interface defaults to the display on mode which continuously displays the meter readings Once the RS 232 connection is made with HyperTerminal the user must type display off lt enter gt to turn off the continuous display The meter will continue to display readings as the user types and continues until lt enter gt is pressed range Same as pressing the Range button on the meter range up Select the next range order Auto 200 mG 2000 mG range dn Select the previous range range Display the present range setting Automatic gt 200 0 mG Automatic gt 2000 mG Manual gt 200 0 mG Manual gt 2000 mG offset Same as pressing the Offset button on the meter set on i Enable the offset correction mode fset off Exit the offset correction mode off set Display the present state of the offset correction mode offset mode on offset mode off log Same as pressing the Log button on the meter Lo 0g on Enable data logging log off Disable data logging Page 4 ELFMeterOperation txt log Display present data logging state logging mode on logging mode off log a S Switch to the single logging style log sty fu Switch to the full loggging style log sty i Display the present logging style logging s
6. l submenu Set the logging interval Use the Left and Right buttons to select a digit or the units and use the Up and Down buttons to change the value Press Enter to set the logging interval Press Left to exit to the main display Log Style Full Single Full Style x y z and mdata no frequency data Single Style selecte A channel x y z or m with frequency data if x y or z is select Press Log to enter the data logging menu Press Down twice to navigate to the Logging Style option Present state is always displayed new state is opposite of display Press enter to switch to the new state Examples Meter is using the single log style Press Log Press Down twice Log Style Full is displayed Press Enter to erase the log data and start using the full style Press Left to exit to the main display or Up and Down to navigate to the other log menu items Page 2 ELFMeterOperation txt Meter is using the full log style Press Log Press Down twice Log Style Single is displayed Press Enter to erase the log data and start using the single style Press Left to exit to the main display or Up and Down to navigate to the other log menu items Logging Status Press Log Press Down three times Press Enter to display the logging status R S one a l t s x number of data readings that have been logged y total number of memory locations available for present logging style t logging interval in seconds Press Up Down
7. t value gt max z lt value gt max m lt value gt alarm Same as pressing the Alarm button on the meter alarm on Enable the alarm alarm off Disable the alarm alarm Okapi ay present state of the alarm mode alarm mode on alarm mode off alarm set Set the alarm threshold in mG alarm thrs perpa the present alarm thresholds alarm threshold x lt value gt mG alarm threshold y lt value gt mG alarm threshold z lt value gt mG alarm threshold m lt value gt mG up Page 6 ELFMeterOperation txt Same as pressing the Up button on the meter down Same as pressing the Down button on the meter Speft Same as pressing the Left button on the meter right Same as pressing the Right button on the meter enter Same as pressing the Enter button on the meter shift Same as pressing the Shift button on the meter display on l l Enable continuous display of meter readings and exit command mode poets oft Disable continuous display of meter readings and enter command mode meas f Display the preset frequency measurement f lt value gt Hz meas x Display the preset x lt value gt mG X lt value gt G OVER RANGE meas y Display the preset y lt value gt mG y lt value gt G OVER RANGE meas z Display the preset z lt value gt mG Zz lt value gt G OVER RANGE u me a S m Display the preset m lt value gt mG m lt value gt G OVER RANGE
8. tyle single logging style ful log status Displays the present log status Style s Reading x of y Interval t s s Single or Full x number of data readings that have been logged y total number of memory locations available for present logging style t logging interval in seconds log list Automatically lists all the logged data log clear Erases the logged data log view x Shows data entry x log intvl t Set the log interval to t seconds rs232 Reserved freg Same as pressing the Frequency button on the meter req on Enable the frequency display mode freq off Disable the frequency display mode ug req Display the present state of the frequency display frequency mode on frequency mode off channel Same as pressing the Channel button on the meter channel x Switch to the x channe Page 5 ELFMeterOperation txt channel y Switch to the y channe channel z Switch to the z channe channel m Switch to the m channe channel Display the presently selected channel channel selected channel selected channel selected channel selected 3 NN x u ma x u Same as pressing the Maximum button on the meter max on Enable maximum mode ma X off Disable maxi mum mode max reset i Reset maxi mum reading and stay in maximum mode max Display present state of maximum mode maximum mode on maximum mode off max x lt value gt max y l