Home
User Manual for GC0321, GC0641, GC1281
Contents
1. The user can request the GSM Commander to report incoming voice calls via the Serial port The user sends VCALLON to which the GSM Commander will reply OK ON Polygon Technologies All rights reserved Page 39 From then onwards whenever the GSM Commander receives a voice call it will send out the following data from the serial port VCALL 0831231234 Where 0831231234 is the originating number and This is the message is the message received Please Note if the GSM Commander is reset for any reason this functionality will revert to the default inactive state No voice calls reported to the serial port This functionality can also be disabled from the serial port by sending VCALLOFF to which the GSM Commander will reply OK OFF 14 2 4 Check Signal The user can request the current GSM Signal Strength via the serial port The user sends SIGNAL to which the GSM Commander will reply like this SIG 60 14 2 5 Check Status The user can request the current Status of the device via the serial port The user sends STATUS to which the GSM Commander will reply like this STATUS lt SIGNAL gt lt Firmware gt lt SERIAL NO gt lt ANALOG VOLTAGE gt lt AIRTIME gt Example STATUS Sig 80 FW 7 14 Serial 0948 00054 Analog 000 Airtime 18 14 2 6 Accessing Inputs and Outputs The user can change outputs and read inputs via the the Serial Port To set an output Send
2. This tab allows the user to program the GSM Commander with a number of trigger conditions See chapter 8 This tab allows the user to configure the following gt Network Service and GPRS Settings Temperature Probe Configuration Enable Disable Simcard Pin s Enable Disable Periodic Automatic GSM Reset Set Default Baudrate Show Debug Comms Manually send an SMS via the GSM Commander Write Recipient and IO Names to device Change application size pixel dimensions of software VV VV VV V Y Polygon Technologies All rights reserved Page 24 This tab allows the user to monitor the status of GSM Commander while connected to PC with regards to gt Active SIM GSM Status GPRS Status Power Status Temperature Status Current Battery Voltage if a battery is connected Current Analog Value Signal Strength Airtime Balance Available provided network settings are correct Date Time Status of Behaviour Statements Status of Variables Inputs Outputs Status VV VV VV VV VV V V Y Stuff happening right now This tab allows the user to rename the inputs and outputs to something that means a little more Please Note These IO Name changes will be stored in the setup that is saved to file but will ONLY be stored in the setup that is saved to the GSM Commander if enabled under Settings Tab This tab allows the user enable the analog scaling funtionality when an Analog Expansion Unit is connected to the GSM Commande
3. e Ovens Heaters kettles e Pumps and motors above 500W Please note Keep in mind that if required the above loads can easily be switched on and off using an externally connected relay or contactor One can connect 2 temperature sensors to the GSM Commander at the expansion port via a temperature interface module to measure temperature and allow the GSM commander to perform certain tasks if the temperature falls above or below a certain point The sensor provides an accuracy of 2 C The temperature sensor with 2m 4m or 8m lead and temperature interface is available from Polygon Technologies Analog Input TO INTERNAL ADC 0 gt 0 98V 8 BIT 10K 1 Analog Input 1K 1 Terminals GND GND The GSM Commander provides a single 0 10 8V analog input which can be used to measure incoming voltages from sensor devices Using an appropriate resistor one can also connect 4 20mA sources to the GSM Commander See application note under section 18 What makes this input so special is that the GSM Commander can interpret the analog value on your behalf It is perhaps the best to explain this at the hand of a good example FULL 5000 litre Sensor Gives 7 8v Suppose you have a water tank with a level sensor that is connected to the analog input of the GSM Commander The sensor is such that when the tank is empty the voltage is 1 2V and when the tank is full the voltage is 7 8V The configuration software allows
4. you to request the current reading in a scaled format You would thus tell the software that 7 8V should correspond to 5000 litres and 1 2V should correspond to 0 litres and leave the rest of the calculations to the GSM Commander EMPTY 0 litre Sensor Gives 1 2v Polygon Technologies All rights reserved Page 13 You can now receive a message from the Commander detailing the actual contents of the tank in litres instead of just a raw value Which you would otherwise have had to convert back to real numbers yourself Please note that this feature assumes a linear relationship between the input voltage and the desired output units Thus this will not work very well for a cylindrical tank that is mounted on its side as the voltage from the level sensor is not linearly proportional to the actual contents of the tank The user is also able to define the message to precede and the message to follow the analog value The output of the circuit above feeds to an Analog to Digital converter with a reference voltage of 0 98V and a resolution of 8 bits The full scale input voltage to the GSM Commander is therefore 10 8V The range of the analog input can easily be increased by the addition of a resistor in series with the analog input Below are some examples of resistor values and the resultant input ranges 1K Ohm 0 11 8V 3 3K Ohm 0 14 0V 6 8K Ohm 0 17 4V 10K Ohm 0 20 6V 15K Ohm 0 25 5V The co
5. Status it will send a message either via SMS to each of up to 6 selected recipients via the serial port or to server containing the status of the inputs only inputs 1 12 are displayed gt Global Output Status it will send a message either via SMS to each of up to 6 selected recipients via the serial port or to server containing the status of the inputs only outputs 1 12 are displayed gt Please Call Me it will send a Please Call Me message via SMS to each of up to 6 selected recipients Please note that the Please Call Me will only work if the correct network is selected in the Settings tab of the configuration software gt Baselog Message it will send a message either via SMS to each of up to 6 selected recipients via the serial port or to server containing the information required by the GSM Base Logger software gt Log Status to Server it will send a status message via GPRS to our server to update the status of the GSM Commander on the AirDrive platform Log onto Airdrive to find out more The recipient number can be defined in one of the following six ways Not Used Last voice call number Last sms number Reply to originating number only available with IF conditions 8 1 1 and 8 1 2 a predefined number from the numbers list a new number The user also has the option to insert special characters into the string to create more complex messages See section 1
6. X A statement containing this IF condition will trigger on a specific time every day within a specified range of dates or on every selected day of the week The user can choose between the following four options 1 Everyday 2 Day of Week 3 Once per month 4 Specific Date Range 8 1 17 IF Startup A statement containing this IF condition will trigger as soon as the unit has finished booting up Polygon Technologies All rights reserved Page 31 A statement containing this IF condition will trigger as soon as GSM signal strength meets the specified requirements The user can choose between the following two options Above X e Below X Thus if the user chooses Below X then as soon as the GSM signal strength goes below the specified threshold the statement will trigger The same applies to the remaining options provided their conditions are met The same applies to the other option provided it s condition is met The user is able to specify a Lockout Time for this statement which is the time that after the statement has triggered it will not allowed to trigger again until this time has elapsed If the user selects a Lockout Time of zero and the Below X option the statement will only trigger once will trigger again when the signal goes above and below X 8 1 19 IF Statement X Triggers A statement containing this IF condition will trigger if the referred to statement has
7. changes to contents of this manual without notice at any time Polygon Technologies may be contacted at Email Info gsmcommander com Web www gsmcommander com Telephone 27 0 21 9817062 Fax 27 0 86 6823310 Postal Address PO Box 1655 Brackenfell 7561 South Africa Polygon Technologies All rights reserved Page 48
8. either enable ON or disable OFF statement 8 respectively The GSM Commander will reply with a confirmation message ologies All rights Polygon Techn Page 24 This set of commands allows you to override the GPRS settings that the GSM Commander may have been configured with and can only be sent from the administrator number These override settings are non volatile which means their effect will remain after power has been cycled To configure the GSM Commander to connect to server via a South African network you must send ADMIN GPRSSETUP PRODUCTION To turn off GPRS functionality you must send ADMIN GPRSSETUP OFF To disable any override and go back to whatever settings were specified by the configuration you must send ADMIN GPRSSETUP SETUP If you need to specify the username and password of your APN Access Point Network you must send ADMIN SETSERVER lt apn gt lt username gt lt password gt UCGPBUPGVQZG The GSM Commander will reply with a confirmation message for each of the above This command can only be sent from the administrator number To re open GPRS you must send RESET GPRS The GSM Commander will reply with a confirmation message This set of commands allows you to override the GPRS logging interval that the GSM Commander may have been configured with and can only be sent from the administrator number These override settings are non volatile which means their effect will remai
9. elapsed Polygon Technologies All rights reserved Page 29 In other words if you select a Lockout Time of 10 minutes a Hold Time of 5 seconds and choose Check if Above Threshold of 5V the statement will trigger as soon as the voltage goes above 5V and remains above 5V for 5 seconds It will then start checking the input again after 10 minutes and trigger once more if the voltage is above 5V for 5 seconds If the user selects a Lockout Time of zero the statement will only trigger once will trigger again when the trigger condition has changed and becomes true again 8 1 9 IF Temperature A statement containing this IF condition will trigger if the temperature measured at the probe meets the specified requirements The user can choose between the following four options e Check if Above Threshold e Check if Below Threshold e Check if Inside Window e Check if Outside Window Thus if the user chooses Check if Above Threshold then as soon as the temperature measured at the probe goes above the specified threshold the statement will trigger The same applies to the remaining options provided their conditions are met The user is able to specify a Lockout Time for this statement which is the time that after the statement has triggered it will not allowed to trigger again until this time has elapsed The user is also able to specify a Hold Time for this statement which is the tim
10. enhancing reliability Only able to view the current status of the unit via Airdrive Polygon Technologies All rights reserved Page 3 Weight 200gram Dimensions 146 2 x 85 2 x 27mm Power Supply 13 15V DC via DC Jack Power Consumption 2 5W Current Consumption 60mA at idle no inputs or outputs active Operating Temperature 10 C to 60 C Storage Temperature 20 C to 80 C Digital Inputs Opto isolated Inputs draw 2 45mA depending on voltage Can accept any DC signals of any type including gt Dry Contacts gt Open Collector NPN gt Closed Collector PNP gt DC Voltage 3 20V Digital Outputs 2 x SPDT Relay Contact rating 8Amp DC 10 48V or 4amp AC 110 400V Expandable to maximum of 32 Analog Inputs 1 x Analog input 8bit resolution 0 10 8V 4 20mA IO Connector type Pluggable terminals GSM 850 900MHz Output Power Class 4 33dBm 2W GSM 850 900MHz Sensitivity 107dBm GSM 1800 PCS 1900 Output Power Class 1 30dBm 1W GSM 1800 PCS 1900 Sensitivity 106dBm Model Dependent See Feature Matrix in Section 2 The setup software requires a PC with the following specifications Operating system Win2000 WinXP Vista Win7 Computer Architecture Pentium 2 or higher IBM compatible PC Disk space 2MB Ports 1 x free USB port Polygon Technolo
11. not be pretty but it works Ee a as ay In this example we discuss the use of periodic messages to ensure that your GSM Commander produces a billable event on the network on a regular basis If you use a prepaid SIM card the network will de activate your SIM card if it has not been used for some time See Section 6 4 We will create two behaviour statements The first will send a free of charge please call me message every day to give you a confirmation that the unit is up and running The second will send a Status SMS to your cellphone once a week to ensure that the SIM card remains active on the network The status message also gives you the total airtime remaining Configuration Using the setup software we create a behaviour statement that will read as follows IF Date Time is 12 00 THEN Send Please call me to 27821231234 A second behaviour statement is created that reads IF Date Time is 8 00 On every Monday THEN Send Status Message to 27821231234 The GSM Commander could also be configured to only execute an action during a specific date range A time constraint could also be assigned to any trigger condition J Ss E i In this example we need to monitor an alarm system and in the case of an alarm the GSM Commander must make a voice call and send a message to one or more numbers Polygon Technologies All rights reserved Page 43 Hardware We connect the al
12. screw There is also a DINrail mounting kit available separately Please note The GSM Commander is not water or weatherproof The GSM Commander must be mounted indoors or inside an appropriate IP65 rated weatherproof enclosure The guarantee does not cover damage resulting from water ingress DO NOT mount the GSM Commander inside a steel cabinet unless you also mount a separate antenna on the outside of the cabinet Suitable antennas can be ordered from Polygon Technologies The GSM Commander itself provides 2 signal inputs The number of inputs can be expanded by the addition of Expansion modules up to a maximum of 32 inputs Each of these inputs have 4 terminals associated with them Internal positive supply 14V IN_ Positive input IN_ Negative input Internal negative supply Zero volts To connect a switch or contact to an input simply connect the switch between the and IN terminals and a wire between the and IN terminals The reverse is just as suitable i e that you connect a wire between and IN and place the switch between and IN ANT SIM Card Instructions P gt Verify that SIMs do not have a PIN enabled P gt Verify that the SIMs work in a handset before installing into this device WNN GSMCOMMAND DER COM GSM COaMMANDER PROGRAMMABLE TELEMETRY CONTROLLER SaL EL 1 C NS A P TA 2008 710 INPUT OUTPUT ES ee ee INPUT 2 __ ANA i i2v8aT J OUTPUT 1 OUTPUT 2 You may ne
13. that will read as follows IF Message is received containing Lights on from 0821231234 THEN Activate Output 1 We create a second behaviour statement that will read as follows IF Message is received containing Lights off from 0821231234 THEN Deactivate Output 1 In this example we need to open a gate in response to a missed call from any number in a list of accepted numbers This is an ideal method to control a communal gate in a complex Hardware Many gate openers require a pulse to open and second pulse to close We will use the output of the GSM commander to supply this pulse at the position where the open close switch is normally connected to the opener Configuration Using the setup software we create a behaviour statement that will read as follows IF a Voice Call is received from any listed number THEN Activate Output 1 for 1 Sec Pause for 20 Sec Activate again for 1 Sec Polygon Technologies All rights reserved Page 44 In a few instances it may be necessary to transmit the status of a contact to a remote point Let us use an alarm as example If the alarm at your home sounds you may want a warning light to switch on in a remote location and a voice call to be placed to a specified number For this example we will use two GSM commander units one at the local alarm system and another at the remote location Local GSM Commander Hardware We connect the alarm output 12V signal that drive
14. the following default Serial parameters Baudrate 38400 Data Bits 8 Stop Bits 1 Parity none Flow control none Please Note The default baudrate won t work if it has been changed and saved into non volatile memory See section 10 2 7 to find out more Please Note All configuration messages ARE case sensitive 14 2 1 SMS Sending You can send an SMS message directly from the GSM Commander by sending the following SMSTX 0831231234 This is the message Where 0831231234 is the recipient number and This is the message is the message to be sent The GSM Commander will reply with OK if all is well otherwise it will reply with ERROR 14 2 2 SMS Receiving The user can request the GSM Commander to relay incoming messages via the Serial port The user sends SMSRXON to which the GSM Commander will reply OK ON From then onwards whenever the GSM Commander receives any SMS it will send out the following data from the serial port SMSRX 0831231234 This is the message Where 0831231234 is the originating number and This is the message is the message received Please Note if the GSM Commander is reset for any reason this functionality will revert to the default inactive state No messages getting relayed to the serial port This functionality can also be disabled from the serial port by sending SMSRXOFF to which the GSM Commander will reply OK OFF 14 2 3 Voice Call Receiving
15. 0 See section 15 to find out more about the serial port Polygon Technologies All rights reserved Page 33 8 2 3 THEN Place Voice Call A statement containing this Action will place a voice call to each of up to 6 selected recipients The user is able to specify the time to ring the number of calls to make as well as the time between calls The recipient number can be defined in one of the following five ways e Not Used e Last voice call number e Last sms number e A predefined number from the numbers list e Anew number Please Note If a call is answered then hung up subsequent calls for this event will be cancelled 8 2 4 THEN Enable Disable Statements A statement containing this Action will enable or disable up to a maximum of 8 selected behaviour statements such that it will be allowed to trigger if it is enabled and not be allowed to trigger if it is disabled 8 2 5 THEN Enable Disable ALL SMS Sending A statement containing this Action will enable or disable ALL SMSes meaning that if it is enabled it will allow the sending of any SMS messages and if it is disabled it will inhibit the sending of any SMS messages 8 2 6 THEN Set Multiple Outputs to Pattern A statement containing this Action will change the status of multiple outputs to a certain state 8 2 7 THEN Change Variable A statement containing this Action will change the selected variable according to specified actions T
16. N lt do something gt such as IF Input 1 goes Active THEN send Generator Tripped to 0831231234 Max Number of Phone Numbers The maximum total number of phone numbers that can be programmed into the unit Max Number of The maximum total number of messages that can be programmed into the unit Messages Max Number of The maximum total number of behaviour statements that can be programmed into the Statements unit GPRS Enabled If yes the unit is able to be registered onto the AirDrive Platform which can allow it to log it s status log it s events have remote config and remote output control via GPRS Temp Probes Supported The number of temperature probes the base unit can accept 0 10v Analog Inputs The number of analog Inputs available Battery Power Monitor The ability to detect power failures and monitor a connected battery Extended Analogs Allows the possibility to connect an Analog Expansion unit which will provide an additional 8 analog inputs DTMF Decoder If YES the unit is able to recognize and respond to key presses on a remote phone during a voice call SIM Card Slots If Single the unit has only a single SIMcard slot If the SIMcard in that slot becomes faulty or the associated network goes down the unit loses communication ability If Dual the unit can switch over to a secondary SIMcard if it detects problems on the primary SIMcard thus greatly
17. OUTON The GSM Commander will respond with Now send two digits corresponding to the output you want to set if you want to set output 1 then send 01 Likewise if you want to set output 13 send 13 In a similar way you can clear outputs by sending OUTOFF To read the inputs simply send READIN The GSM Commander will respond by sending a hexadecimal representation of all the digital inputs It will be of the form INPUTS 0x00000004 In this example Input 3 is set and the rest are cleared 14 2 7 Customizing Baudrate The user can request the GSM Commander to change the serial Baudrate to any of the following values gt 1200 Send BAUD1 Expect the following reply OK BR 1200 gt 2400 Send BAUD2 Expect the following reply OK BR 2400 gt 4800 Send BAUD3 Expect the following reply OK BR 4800 gt 9600 Send BAUD4 Expect the following reply OK BR 9600 gt 19200 Send BAUD5 Expect the following reply OK BR 19200 gt 38400 Send BAUD6 Expect the following reply OK BR 38400 gt 57600 Send BAUD7 Expect the following reply OK BR 57600 Polygon Technologies All rights reserved Page 40 Right after sending the reply the GSM Commander will re initialize the serial port to the requested baudrate Note that per default this setting is volatile if the GSM Commander is reset for any reason this functionality will revert to the default baudrate of 38400 To save the current baudra
18. Polygon Technologies CC info gsmcommander com Reg no 2003 027 995 23 Tel 27 0 21 981 7062 VAT no 4310220167 Fax 086 682 3310 User Manual for GC0321 GC0641 GC1281 Applicable to software package Version 7 15 and up Revision V7 3 Last Edited 27 February 2013 Before Attempting to connect or operate this product please read these instructions in its entirety This manual is intended to provide detailed technical specifications and explanations to the basic user as well as the more technically minded person This manual is a live document and will be updated often with new information Please insure that you have the latest version by checking our website at http www gsmcommander com Changelog SD 27Feb 2013 Changed front page SD 14 Feb 2013 Some reformatting CDH 11 Feb 2013 Changed section orders updated table of contents updated message parameters updated styles PEAUUNCS icc ssucmcsmaueedweddarenaelnewevennsmcanuansasevsawenduuaaaeesseeweenabeasawsaaarnnsdedsssessesseensens 3 SPECIICALIONS nnscaicansnnarasanadacadadeanvxnindaadanaaamdaagmaasangaweenenaiwdan daeaiaedacamennenmeeneaaen 4 System requirements x4 sccossdcnrtueds adc ccaacdawncatandanetssceansthedudeesnnsadenssegiaaseeteneaaeusseaved 4 DIMENSIONS sv vccissiavisccssiowemsawvndansaienadnnducms neice E SENEE EEEE NERE EESE ENERE 5 ISLAUALION 5scccsastvnnenstiehecdaninaasecaeeasasaantecenaniedenesduntaasoabauanens EEEE EARRA 6 EDVIrONMEN sessie
19. Specifically ALL INPUTS and OUTPUTS will be disabled The GSM Commander will still be able send receive SMSes and voice calls This is very handy for applications where the only requirement of a battery is for power failure notifications Mounting an external lead acid battery can be troublesome This option will effectively solve the problem Another area where this feature is important is in security applications Sometimes criminals would break open the enclosure and cut all the wires in an effort to prevent an SMS or call from being made The internal battery will be impossible to turn off and thus they cannot prevent the transmission 5 13 1 Resetting the GSM Commander GCXXXX The GSM Commander will leave the factory in a constant reset state The moment an external power supply is connected to the GSM Commander it the internal battery will switch on Now that it is almost impossible to turn the GSM Commander off it may be a problem to reset it To reset the GSM Commander the Turn Off dongle that is supplied with the unit must be inserted into the GSM Commander s RS232 port This will place the GSM Commander in in a constant reset state Removing it will return the GSM Commander to normal functionality 5 13 2 Pitfalls It is NOT recommended to remove or insert the SIM card while the GSM Commander is powered up thus we advise that the GSM Commander should first be in the reset state see 6 13 1 before removing o
20. T DDDDDDDDDDDDDDDDOO L EN IN HIN IN cof we no com ne no STATUS PU INPUT 2 OUTPUT 1 OUTPUT 2 Above12V when active Input Voltage range Required Series resistor 20V 40V DC 1K ohm The and terminals are connected to the input power supply of the GSM Commander and are provided to make it easy to connect dry contacts to the GSM Commander If the power supply is 14V the voltage at the and terminals will be slightly less at about 13 8V due to an internal series diode for reverse polarity protection Polygon Technologies All rights reserved Page 11 Here is a schematic of the input circuit used on the GSM Commander 1 IN 4 470R IN Opto Isolator Drawing power for external hardware from the power terminals on the input One should not attempt to draw more than 50 100mA in total from the power terminals at the inputs on the GSM Commander For each expansion unit the same applies The GSM Commander itself provides 2 x 8A DC Relay outputs The number of outputs can be expanded by the addition of Expansion modules up to a maximum of 32 outputs Each of these inputs each have 3 terminals associated with them Each of these inputs each have 3 terminals associated with them COM Common Terminal N C Normally Closed Terminal N O Normally Open Terminal When the output is off the COM and N C terminals will be internally connected to each other When the output i
21. ables A H automatically By default these values are in millivolts or microamps depending on what range has been selected on the Analog Expansion unit When the analog values arrive from the Analog Expansion unit the GSM Commander can be configured to apply a scaling factor to each variable and these are set up under the Analog Scaling tab This allows you to set the device up such that the variable contains a real world unit of measure Model Dependent See Feature Matrix in Section 2 Polygon Technologies All rights reserved Page 36 The GSM Commander supports time constraints which can be setup for any statement Time constraints will prevent a statement from triggering outside of the preselected times and days of the week The GSM Commander can also be configured to trigger a statement at a certain time on a certain date or group of days The current time and date can be set in one of two ways either by SMS or by clicking on the tab Set to PC time in the software interface under the Status Tab By means of SMS you would send a special SMS message to the GSM Commander containing the text SETTIME The cellular network supplies the time and date with any message that is sent and the GSM Commander sets its own time according to this Please Note The GSM Commander will lose its time if power is removed and no battery backup is used Upon power up if any statement has a time constraint enabled the GSM Co
22. and input output constraints for any IF THEN statement pair so that a statement will only be allowed to trigger at certain times of day and on certain days of the week or only if certain input output conditions are met ported IF Conditions 8 1 1 IF a Message is Received A statement containing this IF condition will trigger on the arrival of a SMS message The user has a choice of the following four options e From Any number Containing Anything or a Specific Message From Any number appearing in the list Containing Anything or a Specific Message From a Specific number in the list Containing Anything or a Specific Message e From Serial port Containing a Specific Message Serial Port refers to the connection labeled RS232 Thus if the user chooses From Any number Containing Anything or a Specific Messgae then literally any SMS if not specified from any number will cause the statement to trigger This will include SMS messages from private withheld numbers Note the word containing in this condition If you have a trigger condition like this one IF a Message is Received From Any number containing Apple is received from XYZ then lt ACTION gt The statement will trigger on arrival of any of the following messages Apple APPLE The Red apple You will notice that trigger text strings are NOT case sensitive Both Apple and APPLE will work fine It is also
23. arm output 12V signal that drives the siren to one of our inputs as described in section 6 8 The positive wire from the alarm panel is connected to the IN terminal and the negative wire is connected to IN Configuration Using the setup software we create a behaviour statement that will read as follows IF Input 1 Goes Active THEN Place voice call to 27821231234 We create a second behaviour statement that will read as follows IF Input 1 Goes Active THEN Send Alarm triggered via SMS to 27821231234 27843214321 The first statement will cause a voice call to be placed to 27821231234 in the event of an alarm The second statement will cause a notification SMS to be sent to both 27821231234 and 27843214321 This is an example of how the GSM Commander can have multiple actions triggered by a single event in this case an input becoming active Note that the voice call will not say anything when the call is answered One will typically use Caller ID to identify the GSM commander number and this will be enough to let you know that there is something wrong at home In this example we need to switch a 220V light bulb on or off via a suitable SMS message from a specific number listed on the GSM Commander Hardware We connect light bulb to a 220V power source via the output 1 contact on the GSM commander exactly as described in section 6 9 Configuration Using the setup software we create a behaviour statement
24. becomes Active THEN Place Voice Call to lt your number gt Statement 2 IF input 1 becomes Active THEN Send XYZ via SMS to lt your number gt Statement 3 IF input 1 becomes Active THEN Activate Output 1 for 10 minutes If input 1 becomes active all the above statements will trigger and their associated actions will take place The action for the first statement will be executed first Alternatively IF Statement X Triggers could have been used See 8 1 18 The GSM Commander support the use of parameters in predefined messages This allows the user to insert and refer to certain values in message The following is a list of all available parameters case sensitive together with their descriptions gt t Current time HH MM SS d Current date DD MM YYYY a Current analog input reading 0 255 Unit s serial number f Unit s current firmware version b Battery voltage in volts p Current power status of mains 1 Temperature probe A reading in C 2 Temperature probe B reading in C s GSM signal strength in c Airtime credit remaining local currency i Current status of inputs 32 bit hexadecimal bitmap o Current status of outputs 32 bit hexadecimal bitmap v Last received voice call number m Last received message number q Last received message text r Carriage Return 0x0D n Line Feed 0x0A A Variable A B Variab
25. ces gt Universal Serial Bus controllers ee 9 se meo etl e change settings Polygon Technologies All rights reserved Page 46 Double Click on Universal Serial Bus USB controllers In the list of USB controllers you should see an item called GSM Commander If this item is not present the drivers are not installed correctly To install your drivers go to C Program Files GSM Commander V7 drivers drv_install and run GSMC_USBXpresslInstaller exe or run Reinstall drivers Start gt All Programs gt GSM Commander V7 gt Reinstall drivers This will install your drivers This is a problem state and may be caused by a supply voltage that is too low The supply must be in the range 10 24V If this problem persists the GSM Commander is faulty Cause 1 Airtime problem The airtime on your SIM card may be depleted or the SIM card may have been de activated by the network Refer to Section 6 4 SIM Card Cause 2 Reception problem You may have bad reception in your area preventing the unit from connecting to the network Please check using a regular cellular phone that there shows 1 2 bars of signal right next to the GSM Commander Refer to Section 6 5 Antenna Cause 3 Bad configuration You may have configured the unit incorrectly Please send a status request message to the unit and see if it responds Section 6 15 If it does respond the unit is operating correctl
26. codttonseeseaoh 27 Supported THEN ACUOMNS ics susssodiecesnaseetedsscasectsedde ET e CEs E ATER Tn E TOERE SENEE 32 Multiple Actions to a Single IF Condition sssesesssssssesssecsseesssossscsssosssessessessese 35 Message PALAMELONS ccasaniasaxcaicnnaavaamanaanand senen kosasida nene sanaa eaaa anni 35 VariaDleS esses dpancivninnw veuiveletatsn saw bivonieicuiincianinntiasliatslcintemienicunin E R a aaas 36 Timed operations sssscsassosssssoisassine sedndvausaswuawessetanssnseedivadeaalannsssasansanstatawsenennds 37 Prepaid Airtime voucher loading sssseeseeseccsccsesecseeceeceececoesececoesecececeesececeeseo 37 Serial DOM csncsdavsansasiausenadiarags an a a a R EEE E GE SN EEEa 38 RS232 COMO UALION nicapreanGacssinac tebsauennscanuponscniseusacaed EE EEE EEEE 39 Serial PUMCLION AIRY sun ctrnacagenenelscoudauedwanesecnncitetaties a a e a a E EE 39 Firmware Updates oc iiceessvecsinscocasiasdnuodssussectaceweosseuswsswes tia EErEE EO EEEak 41 Low power Battery Operation ssessessessesseseeseesesosecesossossoesossoesoessesesesseseoeoe 42 4 20mA Analog Application Note ssesseceeceeceeceecsceeoececsesececececoesececsececeeecoeseoeo 42 Application EXGINDIES csccccnstsieavarsnwexandech snedanounsdseustsnauretaraesiyneocennteneomerneanernexees 43 Troubleshooting asesmen a aa a a E aa E na EE E Ea 46 GUATANUES a cicsvsieccnaeavadacsicwndadeasncielindeleueneseanincmeue ne cuddenaanesneaeaeeewabediassadaameateasenions 48 Important Not
27. e e e e e e Airtime running low gt on for 10ms off for 500ms 2 short flashes per second 1 1 1 1 1 1 l l I Signal is low gt on for 50ms off for 50ms very fast flash TOUT UTEP ITC Cri retire ii iireriirer ier Problem with GSM engine gt on for 100ms off for 500ms on for 100ms off for 500ms on for 500ms off for 500ms 2 short and 1 long flash a m a Setup is corrupt gt on for 50ms off for 100ms on for 50ms off for 100ms on for 50ms off for 1000ms 3 short flashes C C C CE Supply voltage below 9 5V RED LED GSM gt OFF GSM engine OFF gt on for 600ms off for 600ms 1 flash per second m m e GSM engine not finding network gt on for 75ms off for 3000ms 1 flash every 3 seconds m n n n GSM engine registered OK gt on for 600ms off for 600ms 1 flash per second GSM busy with a voice call Polygon Technologies All rights reserved Page 18 5 17 1 Status Request The GSM Commander even with a blank configuration has a built in test feature If the GSM Commander receives TEST GSMC as an SMS message it will reply to the number that sent the message with the following text DT 01 01 2013 12 00 00 lt Indicates current date amp time of the GSM Commander Sig 68 lt Indicates the received signal strength Airt 35 lt Indicates t
28. e of a power failure While the GSM Commander is powered the battery will be trickle charged by the GSM Commander It is therefore important to note that the battery level will only be checked while a power failure is in progress 8 1 13 IF Prepaid Airtime lt X A statement containing this IF condition will trigger if the prepaid airtime goes below a preset threshold level The user is able to specify a Lockout Time for this statement which is the time that after the statement has triggered it will not allowed to trigger again until this time has elapsed The GSM Commander will check the prepaid airtime balance from time to time and the statement will trigger if the balance is below the selected threshold Please Note To use this option the user obviously needs to use a PREPAID SIMcard Important Under the Settings Tab in the configuration software you need to have DO NOT Check Airtime Unchecked which is found in Edit Settings Also make sure that the correct network is selected 8 1 14 IF time elapsed gt X A statement containing this IF condition will trigger every X seconds or minutes 8 1 15 IF Statement X has not triggered in a certain period A statement containing this IF condition will trigger if the referred to statement has triggered in a specified period Thus this type of statement actually monitors the triggering behaviour of another statement 8 1 16 IF Date Time
29. e phone can start and then disable the SIM Card PIN See your cellphone documentation on how this can be done e Verify that you are able to send an SMS message The SIM card will now work with the GSM Commander Please Note If you are using a prepaid SIM card be aware that if the SIM card has not produced a billable event on the network for a long period of time typically 3 months the card will be de activated by the network and the SIM card then becomes useless It is strongly recommended that you configure the GSM Commander to send you an SMS every now and then once or twice a week so that your SIM card remains active on the network The GSM Commander can ONLY check the airtime of a PREPAID SIM card The GSM Commander is supplied with a basic antenna operating in the GSM 900MHz and 1800MHz frequency bands Screw the antenna to its connector on the unit only finger tight Verify using a cellphone that there is sufficient signal at the proposed installation site On a phone with a 4 or 5 bar signal strength indicator you should have at least 1 2 bars of signal If the signal is too weak the GSM Commander may have trouble sending or receiving SMS messages In these cases try and find a better location or order one of our special antennas If you are outside South Africa you may require a different antenna The other frequency bands are gt GSM 850MHz gt PCS 1900MHz Your network will be able to tell you which frequ
30. e that the trigger condition must continuously be true before it will be allowed to trigger In other words if you select a Lockout Time of 10 minutes a Hold Time of 5 seconds and choose Check if Above Threshold of 30 C the statement will trigger as soon as the temperature goes above 30 C and remains above 30 C for 5 seconds It will then start checking the temperature again after 10 minutes and trigger once more if the temperature is above 30 C for 5 seconds If the user selects a Lockout Time of zero the statement will only trigger once will trigger again when the trigger condition has changed and becomes true again Please Note To use this option you need to have a temperature probe connected to the expansion port of the GSM Commander via a temperature interface module Also make sure that the correct type of probe is selected in the Temperature Probe Configuration box under the Settings tab in the software 8 1 10 IF Power Failure Detected A statement containing this IF condition will trigger if the power supplies to the 2 1mm DC jack power connector on the GSM Commander is interrupted The user is able to specify a Lockout Time for this statement which is the time that after the statement has triggered it will not allowed to trigger again until this time has elapsed The user is also able to specify a Hold Time for this statement which is the time that the trigger cond
31. e to GSM Commander ONLY USB and not the Power Press Windows key and Pause simultaneously on your computer keyboard This will bring up the System properties window as below FAE coc bael Stem and securiy Stem JO Scorn ConvatPorel Control Panel Home 9 Device Manager a Remote settings System protection Advanced system settings Windows edition Windows 7 Ultimate System Rating Processor Installed memory RAM System type Pen and Touch View basic information about your computer Copyright 2009 Microsoft Corporation All rights reserved ER iindaws Besienceindes Intel R Celeron R CPU E3200 2 40GHz 2 40 GHz 2 00 GB 32 bit Operating System No Pen or Touch Input is available for this Display Computer name domain and workgroup settings See also Computer name Action Center Windows Update Performance Information and Tools Workgroup Full computer name Computer description Step 2 Select Device Manager This will open the device manager window as below File Action View Help es m bm p gi Computer gt Disk drives p i Display adapters b DVD CD ROM drives p 5 Human Interface Devices gt qm IDE ATA ATAPI controllers b F Infrared devices p Keyboards p A Mice and other pointing devices b E Monitors b P Network adapters p IF Ports COM amp LPT p 2 Processors b a Sound video and game controllers p ill System devi
32. ected digit tone is detected during an ongoing voice call Obviously for this to work you need to have another statement that will answer and keep the call open typically something of the form IF Voice Call is Received from ABC then do nothing at the setup of this statement is a check box where you can select to keep the incoming call open Please Note If the Stay On call option is selected it should be defined in the last IF Voice Call is Received behaviour statement if any exist 8 1 8 IF Analog Input A statement containing this IF condition will trigger if the analog voltage measured at the terminals meets the specified requirements The user can choose between the following four options e Check if Above Threshold e Check if Below Threshold e Check if Inside Window e Check if Outside Window Thus if the user chooses Check if Above Threshold then as soon as the analog voltage measured at the terminals goes above the specified threshold the statement will trigger The same applies to the remaining options provided their conditions are met The user is also able to specify a Hold Time for this statement which is the time that the trigger condition must continuously be true before it will be allowed to trigger The user is able to specify a Lockout Time for this statement which is the time that after the statement has triggered it will not allowed to trigger again until this time has
33. ed an input to activate when power is supplied from some other unit A good example will be a burglar alarm that applies power to the wires going to the siren In such a case it will bea simple matter of connecting the positive wire to the IN input and the negative wire to the IN input Model Dependent See Feature Matrix in Section 2 Polygon Technologies All rights reserved Page 10 ANT ard Instructions gt at SIMs do not have a PIN enabled Model Gedal P gt Verity that the SIMs work in a handset before installing into this device GC 032 1 WNN GSMCOMMAND DER COM GSM COMMANDER PROGRAMMABLE TELEMETRY CONTROLLER EXPANSION I c ais A SP TA 2008 710 INPUT OUTPUT GSM DOODDDDDDDDDDDDDDODOO IN IN HIN IN com nc no com ne no STATUS mM C CA Supplies 12V when active Other Appliance Please keep in mind that these inputs are designed for 3V to 20V operation If you require to connect a voltage above 20V to these terminals you should connect a resistor in series with the input as shown below Model GC1281 GC0641 GC0321 SIM Card Instructions gt Verify that SIMs do not have a PIN enabled P gt Verity that the SIMs work in a handset before installing into this device WWN GSmMCOMmmMANDER com LESM COMMANDER PROGRAMMABLE TELEMETRY CONTROLLER EXPANSION I c s A Pep ks TA 2008 710 GE INPUT OUTPU
34. ency band s are in use Contact your local electronics supplier about antennas that operate in the 850MHz or 1900MHz bands Contact Polygon Technologies with your request for a special antenna The latest software is supplied on a CD with the product and is also available to download from our website for free at http www gsmcommander com The setup program will start automatically or if the autorun feature is not enabled on your PC you may run the setup exe executable file on the CD to start the setup process The software has been tested to work on Windows XP Windows Vista Win7 The setup process for Windows 7 has been documented here but the process is similar in the other versions of Windows Polygon Technologies All rights reserved Page 7 Screen 1 Welcome to the GSM Commander V7 0641 Install program This program allows you to install GSM Commander V7 0641 on your hard drive tt is strongly recommended that before proceeding you ensure that no other Windows programs are running If you do not wish to install GSM Commander V7 0641 click Exit now otherwise click Next to continue Screen 2 Directory Choose an installation folder and click Next to continue GSM Commander V7 0641 s files will be installed in the following directory C Program Files x86 GSM Commander V7 0641 Disk space needed Available disk space Screen 3 Confirmation You are now ready to instal
35. ensor Pressure Sensor Polygon Technologies All rights reserved Page 42 GSM Commander Wiring Connect a wire from the terminal 14V of any Input from the GSM Commander to the supply voltage input of the sensor Then connect a wire from the output 4 20mA of the sensor to the terminal of the Analog Input Connect GND of the sensor to the terminal of the Analog Input Very important connect a 470 ohm resistor in parallel with the output signal of the sensor and GND as illustrated above This resistor together with the internal voltage divider resistors ensures that the voltage across the Analog Input is between 0 10 8V as required To be more specific the minimum voltage would be 1 88V when the output signal is 4mA and the maximum voltage would be 9 4V when the output signal is 20mA Further Clever Ideas The MacGyver Move The possibility exists that the Temperature Interface module could be used to make an extra 2x Analog Inputs available The slight drawback would be that you would have to make use of the temperature monitoring features in the software to control these inputs Thus a 4mA output signal of the sensor would be equivalent 19 C and a 20mA output signal would be equivalent to 94 C Convert this temperature reading in the Setup Software in order to SMS a value instead of a temperature reading Eg If temperature at probe A stays below 36C then send Alarm 200 Lit in reservoir via SMS to It may
36. ge via Serial port or a message to our server The user can choose between the following fourteen options Plain Message Input Output Status General Status Analog Input Status Able to define own scale and unit Global Input Status Global Output Status Please Call Me Baselog Message Log Status to Sever If the user chooses gt Plain Message it will send a predefined message either via SMS to each of up to 6 selected recipients via the serial port or to server gt Input Output Status it will send a predefined message one for active and one for inactive regarding the status of the selected input or output either via SMS to each of up to 6 selected recipients via the serial port or to server gt General Status it will send a general status message either via SMS to each of up to 6 selected recipients via the serial port or to server containing the following information date amp time signal strength firmware version serial number airtime remaining status of mains power see section 5 15 1 in Basic Manual gt Analog Input Status it will send a message either via SMS to each of up to 6 selected recipients via the serial port or to server containing the status of the analog input The user is able to specify the maximum and minimum value as well as the unit The user is also able to define the message to precede and the message to follow the analog value gt Global Input
37. gies All rights reserved Page 4 27 00 o N bt 146 20 85 20 Polygon Technologies All rights reserved Page 5 Due to the make up of the GSM Commander and it s electronics we STRONGLY advise that it not be installed in close proximity to a variable speed drive or any other electrically noisy equipment DO NOT install the GSM Commander into a metal enclosure unless an antenna is mounted on the outside of the enclosure The GSM Commander has a 2 1mm DC jack connector where a power supply must be connected The power supply should have the following specifications e Output Voltage 14V nominal e Output Current 0 5A e Polarity O e A suitable power supply is supplied with the retail product Please Note It is advised to use a 14V Switching Power Supply if more than one Expansion Unit is connected to the GSM Commander In industrial applications it is advised that the GSM Commander be installed into its own metal housing and be powered from a separate power supply with a DC Filter As opposed to sharing one with other equipment Please Note While the GSM Commander has fairly rugged internal power supply circuitry no special provision for lightning protection is made If the GSM Commander is used in an area that is prone to thunderstorms it is advisable to use a commercially available lightning suppressor The same applies to inputs or outputs that are connected to wires longer than 2 or 3 meters The
38. guarantee does not cover damage resulting from lightning strikes The GSM Commander can operate reliably from voltages in the range of 10 to 24V DC The GSM Commander provides a USB port that connects to a PC using the supplied USB cable This allows the PC to configure the unit The GSM Commander accepts a standard GSM SIM card from any network The SIM card may be prepaid or on contract If the SIM Card is purchased as part of a prepaid plan ensure than the card is loaded with sufficient airtime WARNING DO NOT Insert or remove the SIM card while the GSM Commander is powered Note that airtime will decrease with every SMS that is sent from the unit The unit can automatically detect if the airtime is running low It is user s responsibility to make sure than the airtime is topped up See your network s documentation on how to purchase and load airtime The SIM card is fitted into the back of the unit as indicated by the legend on the enclosure The SIM card will click into place and is removed simply by pressing against it The card will pop out with a click sound ready to be completely removed Polygon Technologies All rights reserved Page 6 Before you install your SIM Card e Install the SIM card into a normal cellular phone e Verify that there is no SIM PIN enabled The phone must not ask for a PIN when switched on with this SIM card inside If the phone does request a PIN you need to enter the correct pin so that th
39. he Utility Start gt All Programs gt GSM Commander V7 gt Configure GSM Commander The software will show this screen when started Here you can select whether you would prefer opening an existing setup from a file on your PC retrieve the setup currently on the GSM Commander just open Open setup from file to the main screen or launch an older version of the software Read setup from device Just open to main screen Launch older version Polygon Technologies All rights reserved Page 20 The GSM Commander Setup Utility software has been designed to make the configuration process of the GSM Commander as easy and user friendly as possibly With this in mind the software has been divided into the following tabs Numbers Messages Behaviour Statements Settings Status IO Names Analog Scaling VV VV V V WV Lock Setup This tab allows the user to program the GSM Commander with the numbers they wish the GSM Commander to communicate with and listen to The FIRST number in the list is defined as the ADMINISTRATOR number Only the Administrator may send configuration SMS messages to the device Please Note The user should adjust the sliding bar at the bottom of the screen to reserve space for numbers to be added removed via SMS See sec 11 1 6 This tab allows the user to program the GSM Commander with the messages they wish the GSM Commander to respond to and respond with either via SMS serial port or GPRS
40. he amount of airtime remaining FW 7 14 lt Indicates the firmware version SN 120641 30225 lt Indicates the serial number PWR 0n lt Indicates status of mains power Batt 13 2V lt Indicates voltage of battery if connected Ana 108 lt Indicates analog value in counts 0 250 tA 23 lt Indicates temperature of Probe A in C if connected tB 44 lt Indicates temperature of Probe B in C if connected IN1 2 0 1 lt Indicates status of inputs 1 and 2 0 active 1 inactive OUT1 2 0 1 lt Indicates status of outputs1 and 2 0 active 1 inactive Please Note The airtime remaining will be displayed as Airt if airtime checking has been disabled or the incorrect network operator has been chosen in the current setup Polygon Technologies All rights reserved Page 19 The following is required to configure the GSM Commander A PC running Windows XP Vista Windows 7 Setup utility installed on the PC Available on the CD supplied with the product USB cable Provided Power supply See 6 2 Antenna See 6 5 VV VY V V WV SIM card s See 6 4 Please note The GSM Commander will eventually startup if no SIM card is inserted but there would be no GSM functionality which means none of the GSM features will work Follow these steps Step 1 Insert SIM card s into unit Step 2 Connect GSM Commander to PC via the supplied USB cable Step 3 Connect power to the GSM Commander Step 4 Run t
41. he user can choose between the following five actions e Increment variable Decrement variable e Clear variable e Set variable to a specific value 8 2 8 THEN Change Active SIM Card A statement containing this Action will change to the selected SIM card or toggle the active SIM Card 8 2 9 THEN Copy Variable A statement containing this Action will copy a selected variable to another variable 8 2 10 THEN Perform Math Operation A statement containing this Action will allow the GSM Commander to perform some basic math operations on the variables 8 2 11 THEN Reset device A statement containing this Action will reset the GSM Commander Please note Only available on the 641 and 1281 models Only available on the 1281 model Polygon Technologies All rights reserved Page 34 It is often required to have more than a single action to be executed for a single Trigger condition For instance if your home alarm is triggered you may want to activate an output that in turns switches on a loud alarm or perhaps pulls the trigger on a rigged up shotgun and you also want to receive a voice call and an SMS as well The GSM Commander will always execute all statements that are eligible to trigger due to a certain event in other words the first statement that is triggered does not void or eat up the event So to take our example we will have a set of statements like Statement 1 IF input 1
42. ice DISCIAIMEN cicstscssncceawsnsures sacs saxnnsionsiusderseskaunscasoesarbsostesnsnasnes 48 Manufacturer Contact DECANS iiiciiascandredcusabansadaataamnenaabadansdadannbansaneiwdanednnsendmuacusans 48 Polygon Technologies All rights reserved Page 2 2 8 da 2 a ul ea fw es o a a iJ e O 4 N 2 le sp s s Z 2 2 8 2 2 3 8 E l ls8 a52 8133 2 kz S S Sy es OE gf ee Ce oe lls gt dal o s S 3 w o w wi a E gt 65 0 k TF g g f 4 Fe eelle wla el A ag zlo c u 5 E a ay OS aE eae Ss rons 2 x A x Ea SS ee eel ee os c se a os i co O x IE 6 S G fl efan z2 2z2z 22 6 PaAls Elaz a A GC0321 2 2 12 12 32 250 64 127 YES 2 1 YES NO NO Single GC0641 2 2 22 22 64 512 128 127 YES 2 1 YES YES YES Single GC1281 2 2 32 32 128 512 128 127 YES 2 1 YES YES YES Dual Matrix Feature Descriptions Model The code used to define between the various units functionality and capabilities Onboard Inputs The number of inputs provided on the base unit itself Onboard Outputs The number of outputs provided on the base unit itself Expandable Inputs Outputs The maximum total number of Inputs Outputs that can be expanded to by fitting expansion units Max Number of Statements A measure of the amount of complexity that can be programmed into the unit Each statement is of the form IF lt ABC happens gt THE
43. important to note that you can trigger multiple statements with different Trigger texts in the same SMS For example if you have the following two statements IF a Message is Received From Any number containing Apple is received from XYZ then lt ACTION gt IF a Message is Received From Any number containing eat is received from XYZ then lt ACTION gt These statements will both be triggered if I eat an Apple is received via SMS Please Note If From Any number appearing in the list Containing Anything or a Specific Message or From a Specific number in the list Containing Anything or a Specific Message are selected and an SMS arrives from a private number the statement will not trigger If the user chooses From Serial port Containing a Specific Message then a specific message sent via a PC through a Serial connection See section 15 to the unit will cause the statement to trigger 8 1 2 IF Voice Call is Received Call Options Hang up or Stay on A statement containing this IF condition will trigger if someone actually places a call to the GSM Commander number The user has the option to select which group of senders originators are able to cause the the statement to trigger The user can choose between the following three options Polygon Technologies All rights reserved Page 27 e From Any number From Any number in the list e From one specific number Thus if the user chooses F
44. ition must continuously be true before it will be allowed to trigger If the user selects a Lockout Time of zero the statement will only trigger once will trigger again when the power is restored and fails again Please Note To use this option the user needs to have a 12V battery connected to the BATT terminals on the GSM Commander or an internal battery see 6 13 The GSM commander will operate from the battery in the case of a power failure 8 1 11 IF Power Restored This trigger condition is the inverse of 15 1 9 Polygon Technologies All rights reserved Page 30 8 1 12 IF Battery Voltage lt X A statement containing this IF condition will trigger if the battery voltage goes below a preset threshold level The user is also able to specify a Hold Time for this statement which is the time that the trigger condition must continuously be true before it will be allowed to trigger The user is able to specify a Lockout Time for this statement which is the time that after the statement has triggered it will not allowed to trigger again until this time has elapsed If the user selects a Lockout Time of zero the statement will only trigger once will trigger again when the voltage goes above and below X Please Note To use this option the user needs to have a 12V battery connected to the BATT terminals on the GSM Commander The GSM commander will operate from the battery in the cas
45. ive remaining Inactive for longer than Is Active Trigger on high level Is Inactive Trigger on low level Thus if the user chooses Goes Active then as soon as the specified input changes from inactive to active the statement will trigger The same applies to the remaining options provided their conditions are met The user is also able to specify a Lockout Time for this statement which is the time that after the statement has triggered it will not allowed to trigger again until this time has elapsed If the user selects a Lockout Time of zero the statement will only trigger once will trigger again when the trigger condition has changed and becomes true again with the last two options being an exception 8 1 4 IF Output This trigger condition is very similar to IF Input as it monitors and output instead of an input 8 1 5 IF Logic Expression A statement containing this IF condition will trigger if the specified logic conditions are met This allows the user to specify interesting combinations like input 1 AND input 2 must be active before action is taken The user is also able to specify a Lockout Time for this statement which is the time that after the statement has triggered it will not allowed to trigger again until this time has elapsed The logic options available includes Polygon Technologies All rights reserved Page 28 AND ALL the selected signals become ac
46. l GSM Commander V7 0641 This program will install GSM Commander V7 0641 into C Program Files x86 GSM Commander V7 0641 Click Start to install GSM Commander V7 0641 Polygon Technologies All rights reserved It is recommended that you leave the install path at the default location Click Click Page 8 Screen 4 Installing Ig sag EE TR ANAE ia Installation is in progress File CA GSM_Commander INI Installation has been completed successfully Click Installation completed GSM Commander V7 0641 has been successfully installed Select the following option if you want GSM Commander V7 0641 to be launched after exiting this install program Launch GSM Commander V7 0641 Screen 6 Clickteam Install Creator Copyright 1999 2011 Clickteam http www clickteam com This install program has been created with the freeware version of Clickteam Install Creator a simple and powerful install maker Visit our Web site and discover Clickteam Install Creator as well as our game and multimedia creation tools PS the product you have just installed has not been created by Clickteam please directly contact its author or publisher for any question about it Polygon Technologies All rights reserved Page 9 The GSM Commander is housed in a very durable ABS casing which has 4 protruding tabs which allows it to be mounted firmly to any surface by means of a
47. le B VV VV VV VV VV VV VV VV VV WV Polygon Technologies All rights reserved Page 35 C Variable C D Variable D E Variable E F Variable F G Variable G H Variable H l Variable J Variable J K Variable K L Variable L M Variable M N Variable N O Variable O P Variable P VV VV VV VV VV VV V WV For example Serial no s signal is s will send Serial no 100641 12345 s signal is 75 For Variables A P it is also possible to specify a decimal point You do this by adding a number 1 2 or 3 after the parameter and this number will indicate the position of the decimal point A1 will show digit after the decimal A2 will show 2 digits etc Let us assume VarA contains temperature and a value of 213 is supposed to correspond to 21 3 C then you can specify this in a message as follows Temperature in fridge is A1 degrees The GSM Commander supports 16 variables A B P whose values can each go up to about 16 million 24bits These variables can be incremented decremented and otherwise manipulated via behaviour statements The value of a variable can be sent via SMS and can also be used to trigger another statement It is important to note that these variables are volatile in that their values will be reset to zero when the device loses power If you are using an Analog Expansion unit with Your GSM Commander the analog values extended inputs 1 8 will be populated into vari
48. ly important when the GSM Commander is powered by means of a battery connected to a solar panel or any other alternative source of power generation Sins 12V6 9 0 ANT m Ge EE s ae coset HW GSMCOMMANDER comM BSM COMMANDER MABLE TELEMETRY CONTROLLER EXPANSIDI P INPUT OUTPUT DDDDDDODDDDDODDDDODOOD E SN feom ne no feom ne f wo STATUS S INPUT2 ax OUTPUT 1LOUTPUT 2 To connect a switch or contact to an input simply connect the switch between the and IN terminals and a 5k6 resistor between the and IN terminals The reverse is just as suitable i e that you connect a 5k6 resistor between and IN and place the switch between and IN This will decrease each input s current consumption when active from 25mA to 2mA Similarly a 5K6 resistor can be connected to all the inputs of the Expansion Unit s to decrease each input s current consumption when active Please Note The above results were obtained by connecting a 14V switching power supply to the GSM Commander Goal To connect a 4 20mA sensor to your GSM Commander SEE 2VO9 O ANT SIM Card Instructions gt Verify that SIMs do not have a PIN enabled Model Gen Eto P gt Verify that the SIMs work in a handset before installing into this device ecoa 9 WHN GSMCOMMANDER COM 5SM COMMANDER EXPANSION 1 a ee ile oe 47 Ohm I0YOOHOVHHHHOHOO HOO Resistor 470 Ohm Resistor Ultrasonic Level S
49. mmander will automatically send a message to the first number in the list requesting a SETTIME reply so that it can set its time This message will be sent a maximum of 3 times The GSM Commander will not allow any time constrained statement to trigger if the time has not yet been set If using a prepaid SIM card it is recommended that prepaid airtime be topped up via an ATM or via your bank s Internet banking portal If your network or bank does not support this you can purchase a normal airtime voucher and remotely send the voucher number to the GSM Commander which will in turn send the voucher number to the network to top up the airtime Your airtime top up voucher is typically a long number and when using this voucher number with a normal cellphone you typically need to frame this number by some preceding and appending text For example with MTN in South Africa you need to send 141 0000000000000 where the 141 is network dependent and the 0000000000000 is the voucher number This detail is typically provided on the voucher slip To send a voucher to the GSM Commander you simply send it an SMS of the form SENDUSD 141 000000000000 from any number where 000000000000 is the voucher number The GSM Commander will receive this and post the voucher number along to the network Polygon Technologies All rights reserved Page 37 The GSM Commander is configured via USB from a PC The GSM Commander also pro
50. n after power has been cycled ADMIN GPRSSETUP LOG5 GPRS logging interval will be set to every 5 minutes ADMIN GPRSSETUP LOG10 GPRS logging interval will be set to every 10 minutes ADMIN GPRSSETUP LOG15 GPRS logging interval will be set to every 15 minutes ADMIN GPRSSETUP LOG30 GPRS logging interval will be set to every 30 minutes The GSM Commander will reply with a confirmation message Polygon Technologies All rights reserved _ Page 25 This set of commands allows you switch from the one SIM card to the other and can only be sent from the administrator number To switch to primary SIM card you must send SIM1 To switch to secondary SIM card you must send SIM2 To switch from the currently active SIM card to the inactive SIM card you must send SIMTOGGLE This command can be sent from ANY number To reset the GSM Commander you must send RESET GSMC Please note Only available on the 641 and 1281 models Only available on the 1281 model The GSM Commander is configured by defining a number of behaviour statements Each statement takes the form of an IF THEN pair You are thus able to select certain trigger conditions that will cause desired actions to be performed Any combination of IF and THEN parts can be assembled into complete statements using the configuration software The GSM Commander can accept up to 128 separate behaviour statements depending on the model One is also able to select time
51. nfiguration software assumes no series input resistor when defining behaviour statements for the analog input The software shows both a voltage and a counts value when selecting trip points for the analog input The counts value is a variable from zero to 255 8 bits If you have connected a 3 3K Ohm resistor in series and you want to select a trip point at say 12V you will ignore the voltage shown by the configuration software and simply select the correct counts value of 214 12 14 x 250 Please note The analog input counts never go above 250 This is a known hardware limitation problem and the input is NOT isolated and must be used with care The GSM Commander provides connections for an external rechargeable 12V battery Under normal circumstances the GSM Commander will trickle charge the battery at a current of about 60mA In the case of a power failure the GSM Commander then starts drawing power from the battery to continue operating In the case of a power failure the GSM Commander can continue operating from the external battery The unit can be configured to perform certain tasks like sending a warning SMS if the battery voltage falls below a certain point and can also perform tasks in the case of a power failure Like sending an SMS and switching on emergency lighting In cases where the GSM Commander is used in conjunction with a large system with its own battery such as UPS systems the battery te
52. ns A The unit must not have been opened or otherwise tampered with If the enclosure of any unit has been opened at all the guarantee will be null and void B The guarantee does not cover damage resulting from excessive input voltages lightning power surges or water ingress A decision about issues A and B will be at the sole discretion of Polygon Technologies This guarantee does not provide for shipping costs This will be for the account of the user under all circumstances Herein the Company will mean Polygon Technologies CC its directors members employees and agents Much effort has been made to ensure the contents of this manual are complete and without errors Nonetheless the Company cannot be held liable for any damages directly or indirectly resulting from any errors in this manual The Company will under no circumstances be held liable for any injuries death or damages that result from the use of this product irrespective of whether such injuries death or damages resulted from a faulty product or negligence of any kind on the part of the Company All Information and images in this manual are proprietary to Polygon Technologies CC The manual as a whole may be distributed and copied freely but no partial content may be used copied or distributed in any way No part of the product including the hardware firmware and software may be copied or reverse engineered Polygon Technologies CC reserves the right to make
53. ou connect a 12V battery to it s battery terminals together with it s main 12V power supply Interface Ribbon cable Supplied with each Expansion unit is a short 10cm ribbon cable for interface purposes but this ribbon can also be very long We have tested up to 10m but we generally recommend a maximum cable run of 7 8m Please contact us if you need a longer ribbon cable The ribbon cable connectors are mounted such that pin 1 on the one end connects to pin 10 on the other Pin 2 connects to pin 9 etc It is important to connect the Expansion port on the GSM Commander to the IN connection on the expansion unit An additional Expansion unit must be connected with its IN connection to the OUT connection of the upstream Expansion unit Model Dependent See Feature Matrix in Section 2 Polygon Technologies All rights reserved Page 16 is of Expansion Unit Polygon Technologies All rights reserved Page 17 The GSM Commander has 2 LEDs to show the current status of the GSM Commander The red LED labeled GSM shows the status of the internal GSM cellular engine while the green LED labeled STATUS shows the status of the GSM Commander as a whole The following table shows how one can determine the current status GREEN LED STATUS gt Solid On O SS S SSS Busy Booting gt on for 500ms off for 500ms slow flash All OK gt on for 200ms off for 200ms fast flash e e
54. r See section 12 This tab allows the user to password protect tabs from being accessed as well as the option to save a new setup to the GSM Commander This feature comes in handy when an installer doesn t want the end user to be able to make changes under certain tabs Page 22 The GSM commander provides functionality to provide some configuration changes to be done via SMS message from the administrator number only Note that the unit cannot be setup by SMS only A PC is still required to perform the initial setup Thereafter some simple changes to the setup may be done using SMS messages Please note The Configuration SMS is NOT case sensitive The following operations can be performed via SMS message Set Administrator number Clear Administrator number Check Administrator number Check Airtime Add a number to the list Remove a number from the list Enable Disable statements Configure GPRS settings Reset GPRS Set GPRS logging interval Switch SIM card Y Y Y Y VV WV WV VV V V Reset GSM Commander This command can ONLY be sent from the administrator number if one exists otherwise it can be sent from any number ADMIN SETADM 0831234567 This will store 0831234567 as the new administrator number The GSM Commander will reply with a confirmation message This command can ONLY be sent from the administrator number ADMIN CLRADM This will remove the current administrator number The GSM Commander
55. r inserting the SIM card Polygon Technologies All rights reserved Page 15 The GSM Commander supports comprehensive expansion by means of the GSM Commander Expansion unit which provides an additional 5 inputs and 5 outputs similar to the ones found on the GSM Commander itself A total of 6 Expansion units may be daisy chained to provide a maximum of 30 outputs and 30 inputs in addition to those on the GSM Commander itself 12V DC Jack and Battery Input on Expansion Unit Each Expansion unit has both a 12V DC jack and battery input so that it could also be powered by a separate power supply and battery Applying power to the Expansion unit either through the DC jack or battery terminal is optional The Expansion unit can draw power via the ribbon cable but under certain conditions it is better to supply a separate 12V source and battery to the expansion unit These conditions are gt When the ribbon cable run becomes very long gt 5m gt Ifyou are going to connect more than one expansion unit gt If you expect to draw power from the input on the Expansion unit gt If you expect most of the inputs and outputs on the expansion to likely be active at once The Expansion unit will automatically detect if power is applied at either of the it s 12V inputs DC jack and battery and thus stop drawing power via the ribbon cable So to ensure that the Expansion unit functions properly in mains power failure conditions it is advised that y
56. rminals of the GSM Commander can be safely connected to the large 12V battery and the GSM Commander can then monitor the battery voltage for you only while power is NOT supplied to the power input connector Also in cases where the user may want to connect other hardware directly to the battery be aware that this will probably drain the battery since the charging current from the GSM Commander is so low Other hardware should rather be connected to the power terminals provided at the inputs See section 5 8 for more information on this Polygon Technologies All rights reserved Page 14 Internal to the GSM Commander the Battery terminal is wired with a 47ohm resistor between the Batt terminal and the positive power supplied to the GSM Commander There is a diode in parallel with this resistor cathode facing to the battery to allow the GSM Commander to draw power from the battery under power fail conditions A resettable fuse has now also been added to give the Battery terminal added protection against voltage spikes and short circuits Suitable batteries are available from Polygon Technologies GSM Commanders with a at the end of their part numbers GCXXXX are equipped with an internal 3 7V li ion battery This battery can keep the unit going even when the mains power is turned off Please Note Because of the low battery voltage the GSM Commander will not be fully functional when running from the internal battery
57. rom any number then literally any call from any number will cause the statement to trigger This will include calls from private numbers The same applies to the remaining options provided their conditions are met Please Note If anyone of the other two options are selected and a voice call is made from a private number the statement will not trigger As soon as the statement triggers the GSM Commander will hang up if option is selected This is of importance because it allows the user to have some sort of feedback that the GSM Commander has in fact responded to the call Since the GSM Commander answers the call for a split second it is cost effective This type of statement option is very handy to use for tasks of high importance for instance the arming of an alarm system If the Stay on call option is selected the GSM Commander will hold the call until the caller ends the call Please Note If the Stay On call option is selected it should be defined in the last IF Voice Call is Received behaviour statement if any exist 8 1 3 IF Input A statement containing this IF condition will trigger if the selected input changes according to specification The user can choose between the following seven options e Goes Active Trigger on rising edge e Goes Inactive Trigger on falling edge e Changes State Trigger on rising or falling edge e Goes Active remaining Active for longer than e Goes Inact
58. s cecina ouciecesaged cogancegs SE E EE EERE EEE DS 6 Power SUDDWosisasncsdadsprnacnersvadidcdencidcobiinbencdduncuadpiaensdevensenehd E OEN E EE ESERE 6 USB POLC emee eia a E EE E EEEE E E SEEE E E E ESN 6 SIM CI diae a E EEE E EEA TE E E EE E E E EE EEA EE EA 6 PEELA INT E A E E E T E E A 7 Software lnstallatiON ssssinsssisirsrsiacrereiscicrunisideser tiesai ion saon EED EEE E EEE EE SEEE 7 Mounting os ccschiaadinececcaavancs eaea er e a aE E d o EE E SS 10 Optically Isolated Digital WWPUtS 5 cic ncssacdcadeccadeadeneedascasenereadaene seca dsabeanndarthenatens 10 DULDUCGS c oscqvereruesaeavemanintnatarnsaaroabnates daxminea wd EEE ETE S EEE TIE E RE E 12 Temperature SensSor ssesecsssssecessosesecesoesececssoesecesocoecesossesesssoscecesescesseeceoe 13 Analog NPU siatotscencsunaceorasertanutscuncanieroniadushondes n n e aee een EEE 13 Battery INDUC cscs eanreise nie aanne e rE EES EEEE IIE EER EEDEN EE TEEPEE EOG 14 Internal BAtveN ys isccvacpuviabunccnnedaad etic sack sounacdeeinces Meds SEEE EEEE TOTEE EEEE ASEE 15 ExpansioMm UML cinccunridacnwannmonnannenshan Ee EEKE SKE EDINE EREE EEE SIENET AERE SAE al 16 Dimensions of Expansion UiMil cuiciindiousancculernidana tewientiamrRivavimidinriienadanssiancaenuiveced 17 status LEDS cni E E ENESE IEEE R E ee 18 Testing the GSM Commander sessssseosesseoseeseoseeseeseeseesesseesesseeseoseesessesseseeso 19 Configuration Via PCs ciacvencsssnsussesecssunsaeswsdusawnsdsancadwnewsaeassexscn
59. s it may be necessary to use an Output to set a flag This allows to you monitor an output does not necessarily have to be physical output which has been assigned to indicate the state of a certain condition For example you want your security system to be automatically armed again in 30 minutes after it has been disarmed in the event someone forgets to arm it again Using the setup software we create the following behaviour statements St1 IF Message is received containing disarm from any listed number THEN disable a group of statements typically these are the statements that are configured to send a SMS when an alarm condition is detected St2 IF ST 1 Triggers THEN Activate Output 12 for 30 Min St3 IF Logic Expression OP12 ALL AND becomes false THEN enable a group of statements these are the same statements that where disabled in St 1 In the above example output 12 was used to set a flag Any output can be used to set a flag Polygon Technologies All rights reserved Page 45 This error can have several causes Cause 1 GSM Commander not powered properly Cause 2 GSM Commander not connected via USB Cause 3 GSM Commander USB drivers not installed It is a good idea to disconnect all cables from the GSM Commander and then reconnecting everything power and USB cable If the problem persists please follow this procedure to verify that the drivers are correctly installed Step 1 Connect USB Cabl
60. s on the COM and N O terminals will be internally connected to each other Note that there are small LED indicators next to the output terminals that will show if the output is ON or OFF if the LED is on then the output is also on In the picture below the output is connected so that the lamp will light up when the output is on 12VO 5 0 ANT Model GC1281 GC0641 AJ GC0321 ESM COMMANDER PROGRAMMABLE TELEMETRY CONTROLLER SIM Card Instructions P gt Verify that SIMs do not have a PIN enabled P gt Verify that the SIMs work in a handset before installing into this device EXPANSION I clas A LP N TA 2008 710 INPUT OUTPUT DDODDDDDDDDDDDDDDDOOF HIN IN IN IN com nc no com ne no STATUS INPUT 1 INPUT2 ANA i izveAT UTPUT L OUTPUT 2 Model Dependent See Feature Matrix in Section 2 This output can be used to control devices and appliances and is rated for 8A DC It may be used to control most types of electrical loads excluding AC motors above 500W Polygon Technologies All rights reserved Page 12 Here are some examples of things you CAN directly switch on and off using the outputs on the GSM Commander e Gate motors and any other motor less than 500W e Mains Lights energy savers incandescents halogens maximum 750W Here are some examples of things that you can NOT directly switch on and off using the outputs on the GSM Commander
61. s the siren to one of our inputs as described in section 6 8 The positive wire from the alarm panel is connected to the IN terminal and the negative wire is connected to IN Local GSM Commander Configuration Using the setup software we create the following behaviour statements St1 IF Input Goes Active THEN send alarm on via SMS to 27833341234 St2 IF Input 1 Goes Active THEN Place Voice Call to 27821121323 St3 IF Input 1 Goes inactive THEN send alarm off via SMS to 27833341234 The above 3 statements detail two actions to trigger in the event that the input goes active One is an SMS message to the remote unit and another is a voice call to a cellphone In the above statements 27833341234 is the number of the GSM commander at the remote location Remote GSM Commander hardware We use a second GSM commander unit at the remote location Here we connect the warning light to output 1 of the GSM Commander so that if the relay is activated the warning light will turn on exactly as described in section 6 9 Remote GSM Commander configuration The configuration of the remote unit will be similar to example 2 control an appliance Using the setup software we create the following behaviour statements IF Message is received containing alarm on from any listed number THEN Activate Output 1 IF Message is received containing alarm off from any listed number THEN Deactivate Output 1 In a few instance
62. te value into non volatile memory send BSAVE at the baudrate requested the GSM commander will reply with OK SAVE Upon startup the GSM Commander will read the value from non volatile storage and set its baudrate accordingly 14 2 8 Other uses gt The GSM Commander can send out a preselected message on the serial port in reaction to a chain of events See Section 8 2 2 for more detail This is very handy for connection to peripherals like serial displays and printers Step 1 Download the setup exe executable file from our website http www gsmcommander com Step 2 Run the executable file See 5 5 Step 3 Connect GSM Commander to PC via the supplied USB cable Step 4 Connect power to the GSM Commander Step 5 Run the Utility Start gt All Programs gt GSM Commander V7 gt Update Firmware Screen 1 The loader utility will show this screen when started The loader utility will now show this screen which means the firmware is being updated The green LED labeled STATUS on the GSM Commander will start flashing On completion the loader utility will close and the unit will start up automatically or if you so wish you can disconnect the power Polygon Technologies All rights reserved Page 41 By the use of current limiting resistors on the inputs of the GSM Commander and Expansion Units the GSM Commander can operate more efficiently in terms of current consumption This is particular
63. tive TRUE or ANY of the selected signals become inactive FALSE OR ANY of the selected signals become active TRUE or ALL of the selected signals become inactive FALSE XOR ANY UNEVEN number of the selected signals become active TRUE or ANY EVEN number of the selected signals become active FALSE 8 1 6 IF Variable A statement containing this IF condition will trigger if selected variable meets the specified requirements The user can choose between the following two options e Check if Above Threshold e Check if Below Threshold Thus if the user chooses Check if Above Threshold then as soon as the specified variable goes above the specified threshold the statement will trigger The same applies to the other option provided it s condition is met The user is also able to specify a Hold Time for this statement which is the time that the trigger condition must continuously be true before it will be allowed to trigger The user is also able to specify a Lockout Time for this statement which is the time that after the statement has triggered it will not allowed to trigger again until this time has elapsed If the user selects a Lockout Time of zero the statement will only trigger once will trigger again when the trigger condition has changed and becomes true again 8 1 7 IF DTMF Tone is Received During Voice Call A statement containing this IF condition will trigger as soon as the sel
64. triggered Thus this type of statement actually monitors the triggering behaviour of another statement Please note Only available on the 0641 and 1281 models Only available on the 1281 model 8 2 1 THEN Change Output A statement containing this Action will change the selected output according to specified actions The user can choose between the following five actions e Activate for a time e Activate for a time Pause Activate for a time e Activate Leave Activated e De Activate Leave De Activated e Change State If the user chooses gt Activate for a time it will Activate the selected output for the selected number of seconds specified gt Activate for a time Pause Activate for a time it will Activate the selected output for the selected number of seconds specified The output will remain off for a selected period after which it will again activate for the selected number of seconds gt Activate Leave Activated it will Activate the selected output and leave it activated The inverse applies to De Activate Leave De Activated gt Change State it will either change the state of the selected output meaning that it will active it if it was de activated and vice versa Polygon Technologies All rights reserved Page 32 8 2 2 THEN Send Message A statement containing this Action will send a message via SMS to each of up to 6 selected recipients or a messa
65. vides a serial functionality that can be used for various functions described later in this manual Both the USB and Serial ports are internally connected to the GSM Commander microprocessor Signaling levels RS232 Connector RS232 Audio 10pin IDC Header Please Note Configuration via the software is ONLY possible through the USB port and configuration messages sent via the Serial port will ONLY get a response via the Serial port The pin out is as follows Pin 1 MIC Can connect to condenser MIC for voice calls Pin 2 MIC Can connect to condenser MIC for voice calls Pin 3 SPR can be connected to an external audio system Pin 4 SPR can be connected to an external audio system Pin 5 RS232 RX to GSM Commander Input Pin 6 RS232 TX from GSM Commander Output Pin 7 Not used Do NOT Connect Pin 8 5V Pin 9 GND Pin 10 14V from input supply Making your own Serial cable for connection to a PC PIN5 on GSM Commander s RS232 PORT TO PIN3 on Female DB9 GSM Commander s RX PIN6 on GSM Commander s RS232 PORT TO PIN2 on Female DB9 GSM Commander s TX PIN9 on GSM Commander s RS232 PORT TO PIN5 on Female DB9 Ground Below is the schematic GSM Commander RS232 Interface to Female DB9 V ae GND IDC Box Header DB9 Female Polygon Technologies All rights reserved Page 38 It is important that any user software that connects via the RS232 connection on the GSM Commander connects using
66. wedseensiasioatsaestsees 20 Configuration via SMS hiescaicvavccscasarawsansiceaancadenensaanddwsabenaehssiaateensdaenasatesendiasaarewn 23 Set Administrator NUMDEN s5ccsvdedacvdnciedtetaeades sianeidpetarsaeceddaatadesiee EENE E Ea aea 23 Clear Administrator NUM ber sessesssesesssesesseesesssessrorossecssosesosesroreecsessesssesso 23 Check Administrator NUM DbETr ssessessessessessesscsseseosecsecssesecseosecsecseeseoseeseeseese 24 Check AIF VINE cawvcicauesn antesoerwegs Ero ee oS EE EEEE TEE A E E E 24 Add a Number to the list oct atteadeaueesy aueecontateadeuncesieataeswaoneterascurenitenenvetueeeessase4 24 Remove a Number from the list seensessossossossosrossosrossosssrorescsseseerosssesroseeese 24 Enable Disable statements cicaccvedsamaacdamenisealeenmemicenctantewasisinainnda daa esneevaman Nemaoa tena teens 24 Override GPRS Settings srein toernee E EEEE EEEN tesasesaimiadiadaenes 25 Bese GP e E A S E E E E A gadis A 25 Set GPRS logging interval ssessessessessesscssessessesecssesecosesecseoseoseeseeseesrsseseee 25 Switch SIM CONG coxcvu seriei iritsi bevheseranncncuad ENE E AET E bad ROEE EEE EEEE EEE 26 Reset GSM Commander csiusccuncckavvereceenscsescecensateerssasd ise ncb save ueedrarkiveds ceive E 26 IF THEN Behaviour statements sssescssccssccseccssccseccsecoececceccecceccecoeccecsecsscseeo 27 Supported IF CONGIRIGINS os carsseevasi na teue dewap in meesoeaeaveswarsuee hasten ndeveseeoersec
67. will reply with a confirmation message Polygon Technologies All rights reserved Page 23 This command can be sent from ANY number and is useful to determine which number is the correct administrator number ADMIN The GSM Commander will reply with the administrator number in the reply message This command can be sent from ANY number and is useful to check the amount of airtime remaining on the unit To check airtime you must send ATCHECK The GSM Commander will reply with a message detailing the current airtime This command can only be sent from the administrator number To add a number to the list the administrator must send ADMIN ADDN 0831234567 The GSM Commander will reply with a confirmation message This command can only be sent from the administrator number To remove a number 27831234567 from the list the administrator must send ADMIN REMN 0831234567 The GSM Commander will reply with a confirmation message Please Note The value predefined by the user via the software under the Numbers Tab as illustrated below will determine how many numbers are able to be added and removed by means of SMS Set number of numbers to reserve for adding removing per sms here This command can only be sent from the administrator number To enable or disable a specific statement in the setup on the GSM Commander the administrator must send ADMIN STATEMENT 8 ON or ADMIN STATEMENT 8 OFF This will
68. y Cause 1 Incorrect operator selection You may have chosen the incorrect operator settings under the SETTINGS TAB in the software interface If your operator is not in the list then choose Other and define the airtime checking and please call me numbers respectively If available Cause 2 Do Not Check Airtime is enabled You may have disabled airtime checking by ticking the box labeled DO NOT Check Airtime which is located in Supplementary Data Services under the SETTINGS TAB Cause 3 Reception problem You may have bad reception in your area preventing the unit from communicating with the network Please check using a regular cellular phone that there shows 1 2 bars of signal right next to the GSM Commander Refer to Section 6 5 Antenna Cause 1 Caller ID on phone is disabled Your Caller ID feature on your phone may be deactivated Please refer to your phone s manual on how to enable this feature Cause 2 Bad configuration You may have configured the unit incorrectly Make sure the number you are calling from is stored in the Numbers List on the GSM Commander Polygon Technologies All rights reserved Page 47 The GSM Commander is guaranteed for a period of 24 months against defects in materials or workmanship Should your product become defective during the guarantee period it will be repaired or replaced at the sole discretion of Polygon Technologies under the following conditio
Download Pdf Manuals
Related Search
Related Contents
Tuf-Lugger User Manual Mode d`emploi Lampe de poche à LED 1 W avec batterie de 取扱説明書【基本編】(9.26MB) MANUAL MINI EXTRUSORA コンパクト酸素O2パック取扱説明書誤記の お詫びと修正版の配布について dServe DSRV-9703C 4GB Grey Guía de Uso - Biblioteca Nr. A087-I ダウンロード Copyright © All rights reserved.
Failed to retrieve file