Home

MU Beta User`s Manual

image

Contents

1. Now you can run the IDEA EXE for the first time Note that if you use Windows NT 2K XP Vista you must use the administrator mode because the parallel port driver asixio sys will be installed typically to C Windows System32 Drivers directory when performing first access to hardware Also you must have write access rights for the directory where IDEA EXE is installed to allow the IDEA application store here the global parameter file IDEA INI You may find convenient to associate the IppP file extension with program IDEA because it allows you to start projects using file managers like Windows Commander ZTreeWin FAR or even Explorer NOTES 1 If you have already installed any previous version of IDEA please un install it before new installation to remove old unnecessary files Your projects and source files will remain unchanged only IDEA directory Projects Examples Example files will be rewritten 2 You must have the write access in directories folders where IDEA is installed and in project target directories Thus is not possible to run the software from e g CD ROM The settings cannot be saved in such case and software gives an error message 3 Software IDEA requires correct date and time setup on your computer IDEA compares the date time information of asm source files and coD debug file and decides whether the source files must be compiled before using the information contained in the debug file Page 6 8
2. 5 Quick Start Step 1 Install MU Beta hardware as described in chapter 2 Hardware installation Step 2 Install the IDEA software as described in the chapter 4 Software installation Windows NT 2K XP Vista users should have administrator rights for first access to hardware Then after automatic driver installation the standard user rights are sufficient Step 3 If hardware and software are installed and emulator is switched on run the program IDEA e g by click on its desktop icon In the very beginning MPASMWIN assembler will be invoked first to build the project Example Then you are asked to select action choose the default Continue to use an EXAMPLE project button Now you see IDEA desktop with Program Memory window and Console window opened Step 4 Now it is necessary to setup hardware communication Select menu Options Global a Global Options dialog will be opened Then select the tab with your equipment name MU Beta and set up the communication parameters Typical setting is LPT1 with base address address 0378h Step 5 Change the project equipment to MU Beta Using menu Project Edit Project open the Edit Project dialog and set up equipment from default DEMO to MU Beta Do not change the part type PIC16F84A Confirm change by pressing OK then select Yes to next question Project will be rebuilt using MPASMWIN and then hardware initialization of emulator FPGA configuration and complete internal set up is
3. invoked You can see that emulator LEDs are now active and indicating hardware status Step 6 Now place another window on IDEA desktop Watches window by menu View Watches command You see the variables HUNDREDS SECONDS MINUTES and HOURS in Watches window Then start the application by menu Run Run command You can see the application running and the variables incrementing This simple application does not access PIC ports and does not require any target application connected Now you can play with this project Run Halt Step Edit source Build open and close various windows etc Page 7 8 6 Further information 1 http tools asix net 2 http www microchip com 7 Contact Address ASIX s r o Staropramenna 4 15000 Prague Czech Republic E Mail sales asix net sales inquiries orders support asix net technical support WWW tools asix net development tools English www asix net main site English www asix cz Czech site Tel 420 257 312 378 Fax 420 257 329 116 MU BETA_MAN_EN 2008 06 27 All rights reserved Copyright 1991 2008 ASIX s r o All trademarks used in this document are properties of their respective owners This information is provided in the hope that it will be useful but without any warranty We disclaim any liability for the accuracy of this information We are not responsible for the contents of web pages referenced by this document Page 8 8
4. off It is not necessary to hold target application supply voltage turned off when MU Beta is powered off The emulator core and application circuitry I O interface are powered separately The emulator core is able to continue emulation even when target power is off but the I Os cannot work The Trigger Out signal the wire with red hook is an output It must not be overload e g by grounding or connecting to target power e The TriggerIn signal is a digital input with allowed voltage range 0 to 5 5V Emulation header must be protected from damage To improve this lifetime it is recommended to operate the emulator with another non precise DIP socket inserted into this all the time In case of damage the socket can be easily replaced The header is shipped with this socket Page 5 8 4 Software installation If you use EMUSB MU Beta USB Interface please install its USB drivers first as described in Hardware Installation chapter Download an installation file from http tools asix net dwnld_idea htm or insert the installation CD ROM ASIX and run installation program idea_xxx exe where xxx means version number The installation uses standard wizzard style installator InnoSetup you should be familiar with Default destination directory or folder is C Program Files ASIX IDEA Advanced users can use another base directory than Program Files The program icon will be placed on desktop but you can supress this option
5. MU Beta Real Time In Circuit Emulator for the Microchip PIC microcontrollers User s Manual AMX CONTENTS 1 MU Beta 1 1 Technical specification 1 2 Packing list Hardware installation Hardware operation Software installation Quick Start Further information oy Oe a Contact 0 O NOUA WWW Page 2 8 1 MU Beta MU Beta is a Real Time In Circuit Emulator for the most popular 6 pin to 18 pin Microchip PIC12 and PIC16 microcontrollers with up to 2 kilowords of program memory including devices with A D converter and two analog comparators Integrated development environment software IDEA for Windows 95 98 ME 2K XP Vista is available Recent list of supported parts latest software version and possible changes to this manual can be found at http tools asix net 1 1 Technical specification e Connects to PC using standard parallel port LPT or USB using EMUSB e Power 9 V DC 300 mA e Dimensions 13 5 x 6 5 x 3 cm e Operation temperature range 10 to 40 C e Operation relative humidity max 90 1 2 Packing list MU Beta Emulator base unit BT CABLE PC connection cable 25 pin parallel port LPT 9 pin MU Beta Note EMUSB MU Beta USB Interface can be used instead of BT CABLE PROTAB Pin protection device connect to target connector HMU10F2xx PIC10F2xx 6 pin devices emulation header board HMUB8 PIC12C5xx 8 pin devices emulation header board HMU12F6xx PIC12F6xx 8 pin devices emulation
6. er in this document 5 The standard emulation headers support devices in DIP packages DIP to SOIC converters XLTO8SO and XLT18SO are available as an option 3 Hardware operation The MU Beta emulator is intended for operation on common conditions Avoid increased humidity dust impurity and explosive atmosphere Do not operate this product in ambient temperature exceeding the range 10 to 40 C Storage temperature range is 10 to 60 C Removing covers is not allowed Emulators are not intended to be connected directly into mains Use only the proper power adapter This must be in good condition Turn off both the computer and MU Beta any time you are about to connect or disconnect the emulator Use only the communication cable shipped with the product Use only PC parallel port do not attempt to connect emulator to PC via other port types Only O to 5 5 V voltage is allowed to be connected to the emulation header If a pin is configured as an output it must not be driven from the target application short circuit to GND or Vdd Exceeding these conditions can result in substantial damage of the equipment Use PROTAB I O protection device whenever possible Insert PROTAB between emulator and emulation header The only reason for removing PROTAB is that you need to exploit full device I O output current which should be rare case Insert remove emulation header to from target application circuitry only with target power turned
7. header board HMU16F6xx PIC16F6xx 14 pin devices emulation header board HMU10 6 8 pin devices emulation header target application cable HMU16 14 pin devices emulation header target application cable HMU20 18 pin devices emulation header target application cable CD ROM ASIX Complete electronic manual software installation files and other information MW903GS Power supply Euro type PRI 230VAC 50Hz SEC 9 V DC 300 mA 2 1 mm connector diameter Shipped only to continental Europe countries MANMUBETA This User s Manual Page 3 8 2 Hardware installation e Turn off your computer e Connect the communication cable there are two options Parallel port Use BT CABLE Sub D 25 to 9 pins cable and connect it to emulator to the connector labeled LPT and to parallel port of computer USB using EMUSB Use EMUSB MU Beta USB Interface and connect it to the USB port at your computer or USB hub Windows then founds a new hardware and will ask you to install drivers Drivers are available on installation CD ROM in drivers EMUSB directory or from tools asix net website Please note that drivers are not digitally signed and you will have to click a Continue anyway button during installation After successful driver installation you will find that the green EMUS LED will lite Connect power adapter 9 V DC 300 mA non stabilized to emulator via the connector labeled 9V DC and then connect to the mains Power is indicated by g
8. reen LED labeled POWER See Note 1 Connect the protection module PROTAB to the TARGET emulator connector See Note 2 Plug the emulation header of your choice to PROTAB and to your application to the microcontroller socket Pin 1 is indicated by a red point on the header See Notes 3 4 and 5 Turn the computer back on NOTES 1 MU Beta has no power switch Do not let the emulator switched on if you do not use it for the extended period Emulator can be connected to PC even with no external power turned on for unlimited period 2 Use the protection module PROTAB between emulator and emulation header whenever possible Its purpose is to avoid damaging the emulator output buffer by eventual short circuit These I O pin output buffers are capable to sink source relatively high current to be compatible with real PIC MCUs but the short circuit to the ground or power supply can cause permanent damage Only applications requiring full output current should be debugged without PROTAB but even for those applications use PROTAB in the beginning of development 3 Emulation headers usage for various PIC MCU types Device Emulation Header All 18 pin types HMU20 PIC10F2xx HMU10F2xx HMU10 PIC12C50x HMUB8 HMU10 PIC12F6xx HMU12F6xx HMU10 PIC16F6xx HMU16F6xx HMU16 Page 4 8 4 Any header contains the emulation socket and two clips labeled TriggerIn and TriggerOut which function is described lat

Download Pdf Manuals

image

Related Search

Related Contents

User Manual  LG Series Mechanical Force Gauge User Manual  Approx appUA100RCP  Kambrook Blender KBL70 User's Manual  Pinnacle Design TR5048 User's Manual  DOCUMENTACION TECNICA. Solo para uso profesional  10 - Rabais & Coupons  Hampton Bay 13387-013 Instructions / Assembly  

Copyright © All rights reserved.