6)-1000A Security Smoke Generator User Manual
Contents
1. 729VVEIYANG 0 iso 9001 2000 CONNECT THROUGH US 1000A Security Smoke Generator User Manual Thank you for choosing VVeiYang security smoke generator Please read this instruction carefully prior to operation Warning x Hot nozzle Keep at least 50 cm distance x The heater of the generator is extremely hot Please be careful when the front cover is opened x No user serviceable parts inside Please contact with an authorized dealer when maintenance is reguired x Please disconnect power before change fuse x Please operate only with adult supervision x Only WeiYang smoke fluid should be used Other fluid may damage the equipment or cause dangers to human physical safety x Do not use without smoke fluid x For indoor use only Please keep dry x Please clear smoke away from room after an ejectment Otherwise residue might be caused Package Before starting installation WeiYang security smoke generator please make sure that you have all the following equipments 1 x WeiYang security smoke generator 1 x Smoke fluid bladder 1 x Mounting set 1 x User Manual Controlling of Smoke The three sets of terminal blocks on the PCB of WeiYang smoke generators Alarm Trigger and Hold off are the keys to generate smoke In order for generator to produce smoke in the critical moment the three sets of connections must be closed circuit at the same time which can avoid wrong action of making smoke
2. For instance both Alarm and Trigger can be set up as switches on the security system control panel On the other hand Hold off usually can be connected to a PIR motion detector or a vvindovv door sensor Hovvever please note in order to stop making smoke either Trigger or Alarm has to be released open circuit Only releasing Hold off cannot stop smoking PCB Connection All relay outputs are offered as volt free contacis The Alarm and Trigger inputs are also reguired to be volt free Tamper When the Tamper connection or its front jumper or the machine front cover or fluid bag chamber cover any one of above four parts is open circuit the LED red light will flash every 2 seconds and the buzzer will produce a long beep sound every minute to vvarn 12V 100mA This terminal block can offer DC 12V 100mA povver output Hold off This terminal can vvork vvith Alarm and Trigger together to activate the smoke generator VVhen all Hold Alarm and Trigger three terminal blocks are closed circuit the machine will start to produce smoke Usually this terminal can be connected to a PIR motion detector or a door window sensor Once the PIR is activated this connection will be closed circuit Hovvever only removing Hold off Making it open circuit cannot stop smoking Verification There are three connection points in this terminal block They are COM NO Normally Open and NC Normally Closed respectively When COM
3. generator Once WeiYang security smoke generators reach ready status Green LED On you can carry out a simple test at generators to check the smoke production Open the front cover and press and hold down the PB1 test button The machine will produce smoke Smoke production ceases once the PB1 test button is released Thank you very much again for your patience and reading this manual If you have any further question about our products please do not hesitate to contact your local distributor or VVeiYang directly VVeiYang Technology contact information Email sales eiyang com Tel 886 2 2269 3323 Fax 886 2 2269 3325 No 13 Datung Street Tucheng Industrial District Taipei County Taiwnd R O C
4. NO are wired to a security control center the relay will give a signal of closed circuit if the smoke machine completes the heating process This signal can notice the security control center that the smoke machine is ready If COM and NC are wired the reverse signal open circuit will be sent out Trigger This terminal can work with Alarm and Hold together to activate the smoke generator When all Hold Alarm and Trigger three terminal blocks are closed circuit the machine will start to produce smoke Generally this terminal can be set as a switch Releasing the switch Making it open circuit can stop smoking Alarm This terminal can work with Trigger and Hold together to activate the smoke generator When all Hold Alarm and Trigger three terminal blocks are closed circuit the machine will start to produce smoke Generally this terminal can be set as a switch Releasing the switch Making it open circuit can stop smoking Example for PCB connection cnc RIR Motion detector 12V 100mA DC input 12VDC 100mA Please notice positive and negative Hold Activated signal Verification FOG Change of status displayed by LED ups Change of status signal output Low Ready Switch Trigger Activated signal Alarm E Notice When Trigger Alarm and Hold are activated at the same time All are closed circuit the generator will start to produce smoke In order to stop making smoke either Trigger
5. and NO are wired to a security control center the relay will give a signal of closed circuit if the machine is activated This signal can notice the security control center that the unit is producing smoke Or this connection can be wired to another security smoke machine When the unit starts to produce smoke this terminal will send the closed circuit signal to trigger the other smoke machine If COM and NC are wired the reverse signal open circuit will be sent out UPS There are three connection points in this terminal block They are COM NO Normally Open and NC Normally Closed respectively When COM and NO are wired to a security control center the relay will give a signal of closed circuit if the UPS is in use This signal can notice the security control center that the UPS is working If COM and NC are wired the reverse signal open circuit will be sent out Low There are three connection points in this terminal block They are COM NO Normally Open and NC Normally Closed respectively When COM and NO are wired to a security control center the relay will give a signal of closed circuit if the smoke fluid is low This signal can notice the security control center that the smoke fluid is lovv If COM and NC are wired the reverse signal open circuit will be sent out Ready There are three connection points in this terminal block They are COM NO Normaliy Open and NC Normally Closed respectively When COM and
6. click sound so that timer can be reset and record the vvorking time of smoke fluid bladder correctly Loose knob and clamp and take old fluid bladder out first Insert fluid pipe connector into new fluid bladder cap out mark Finally put the new bladder back to the generator and screw the knob and clamp tightly Meanwhile please confirm if the LED light is on green light normally Please always replace a full fluid bladder Otherwise it might damage the pump of generator Bag Clamp Fluid Pipe Connecter Fluid Timer Reset Micro switch LED amp Buzzer Status Table Machine Status Buzzer LED Machine Overheating 1 short beep every 5 sec Red flash twice every 2 sec Front Cover or Fluid Bag Chamber Cover is Opened 1 long beep every 1 min Red flash once every 2 sec UPS Power Cut 3 short beeps every 30 Red flash twice every 5 sec sec AC Power Cut 2 short beeps every 30 Red flash once every 5 sec sec Heater Fault 1 long beep every 10 Red flash sec Fluid Level Empty 1 long and 1 short beep Orange flash every 5 min Fluid Level Lovv 1 short beep every 5 min Permanent orange Heating Process Long beep for 30 sec Permanent red incomplete and then 3 short beeps every 5 min DIP 2 switch to ON No buzzer Red and green flash together Normal No buzzer Permanent green Armed No buzzer Green light flashes slowly Test the security smoke
7. or Alarm has to be removed Open circuit Only removing Hold cannot stop smoking O Example of application Security Buzzer Security Smoke Generator Security Strobe Security System Control Center PIR Motion Detector Setting the DIP Switches Open the front cover and locate the DIP switches There is a block of two DIP1 When switch to ON the activation of producing smoke is reverse It means that Alarm Trigger Hold off PIR Alarm have to be open circuit in order to make smoke DIP2 In order to change UPS state Switch UPS ON OFF on the security smoke machine first please switch DIP Switch 2 to ON At this moment the red and green LED flicker And then please press PB2 button for 10 seconds When setting is completed successfully the buzzer beeps After setting please switch the DIP Switch 2 to OFF Then the whole process is totally finished Set Up Duration of Smoke Output Switch DIP switch No 2 to ON Press PB1 for 5 seconds After tvvice short beep every press of PB1 can add 15 seconds The duration of smoke can be set betvveen 15 and 360 seconds VVhen setting is completed svvitch DIP 2 to OFF Replacement of Smoke Fluid Bladder Open the front cover smoke fluid bladder can be changed easily in a fevv seconds VVhen processing exchange of smoke fluid bladder please turn on the povver of the generator and make sure that micro svvitch is activated properly you can hear the