Home
        Leica FlexLine plus Quick Guide
         Contents
1.       i     m  D  x     D  a   n    Leica FlexLine plus  Quick Guide    Version 2 0  English F    when it has to be right eca    Geosystems       FlexLine plus  Important Information about your Instrument    1  AW  S    Laser products    Important Information about your Instrument       Read and follow the User Manual on the accompanying USB stick before using the  product or the accessories delivered with the product        Keep for future reference     e Measuring horizontal and vertical angles   e Measuring distances   e  Visualising the aiming direction and vertical axis        The instruments contain the following laser products     Laser product Laser class       EDM  Electronic Distance Measurement  module  e measurements with reflectors Class 1    e measurements without reflectors Class 3R    EGL  Electronic Guide Light     Exempt Group          Laser plummet Class 2          optional laser product                FlexLine plus  Important Information about your Instrument    CAUTION    CAUTION    e The classification for the EDM and Laser plummet is in accordance with  IEC 60825 1  2007 03    e The classification for the EGL is in accordance with IEC 62471  2006 07         From a Safety perspective  class 3R laser products should be treated as potentially  hazardous    Precautions    1  Prevent direct eye exposure to the beam    2  Do not direct the beam at other people        From a Safety perspective  class 2 laser products are not inherently safe for the eyes   Prec
2.     Instrument compo   nents part 2 of 2                    My       Yi  07    ET  ys  aN                         001947_002 n O P q r S    FlexLine plus  Instrument Components    Focusing telescope image   Eyepiece  focusing graticule   Battery cover   Serial interface RS232   Foot screw   Display   Keyboard  model may vary depending  on instrument   Stylus    FlexLine plus  Instrument Components    Keyboard Color amp  Touch keyboard                         I LL  I  1 x IJK MNO POR   1  n 1    I   a7  stu vwx vz      I B 1I ABC DEF GHI    LL 1                       TSOX_139    Standard keyboard             TSOX_011       10    Alphanumeric keyboard             Fixed keys   Navigation key   ENTER key   ESC key   Function keys F1 to F4  Alphanumeric keypad  Stylus    Keys       Description    Page key  Displays the next screen when several screens are avail   able        FNC Favourites key  Quick access to measurement supporting  functions     User key 1 User key 2  Programmable with a function from the  Favourites menu     Navigation key  Controls the focus bar within the screen and the  entry bar within a field        ENTER key  Confirms an entry and continues to the next field   Turns off the instrument  when held for 3 seconds     ESC key  Quits a screen or edit mode without saving changes   Returns to next higher level        Function keys F1 to F4 that are assigned the variable functions  displayed at the bottom of the screen           Alphanumeric keys for entry of text
3.  and numerical values           FlexLine plus  Instrument Components 11    FlexLine plus  Instrument Components 12    Container contents a bcd i j a  Battery charger    b  Diagonal eyepiece    c  Data cable  USB RS232     d  Clip on bubble    e  Holder for height meter    f  Flat prism    g  Mini prism pole    h  Height meter    i  Protective cover   Lens hood    Cleaning cloth   j  Data cable  USB mini USB     k  Mini prism    I  Adjustment tools   m  Batteries    n  Flat or mini prism adapter    o  Leica industrial grade USB memory  stick    p  Battery    q  Tip for mini prism pole    r  Counterweight  diagonal eyepiece      s  Instrument   t  Manuals     Optional                            3 Technical Data       Environmental Temperature   specifications  Operating temperature    C  Storage temperature    C    20 to  50  40 to  70          Protection against water  dust and sand  IP55  IEC 60529    Humidity   Max 95   non condensing     The effects of condensation are to be effectively counteracted by periodically drying    out the instrument     FlexLine plus  Technical Data    13    FlexLine plus  Care and Transport 14    4    Care and transport    Care and Transport       e Carry the product in its original container or carry the tripod with its legs splayed  across your shoulder  to protect the product against shock and vibration    e Periodically carry out test measurements and perform the field adjustments indi   cated in the User Manual  particularly after the produ
4. SB  or auto detect communication icon  For C amp T  Tapping the  icon opens the Interface Settings screen        Displays the status of the battery  For C amp T  Tapping the icon  opens the Info screen     Displays that offset is active     H Horizontal angle is set to left side angle measurement              FlexLine plus  Operation 17    FlexLine plus  Operation       18       Main Menu a b a  Quick Survey program to begin meas   uring immediately    AE i b  To select and start programs   ca FlexField c  To manage jobs  data  codelists   formats and USB memory stick files   d  To export and import data   e  To change EDM configurations      communication parameters and  re  general instrument settings   Transfer Brees f  To access instrument related tools  such as check and adjust  personal  Startup settings  PIN code settings   ae licence keys  system memory infor   mation and firmware upload   ae Despite an automatic defragmentation  the memory gets fragmented after a while     Please format the internal memory periodically to maintain the instrument perfor     mance        Q Survey program       Quick Survey Zu After switching on and setting up  correctly  the instrument is immediately  ready for measuring     50 0000 g  66 6667 g  Meas   Dist   Store    Meas To start measurements and save the measured values   Dist To start measurements and display the measured values   Store To save the displayed values   L Code To find enter codes  Available on page 4 4 or Code  Or  o
5. autions    1  Avoid staring into the beam    2  Avoid pointing the beam at other people        FlexLine plus  Important Information about your Instrument    Locations of laser  apertures                            003248 002    LED beam red  EGL   LED beam yellow   EGL    Laser beam  EDM   Laser beam  Laser  plummet    Exit for laser beam   Laser plummet        The product must not be disposed with household waste        national regula  ance with the essential requirements and other relevant provisions of  tions applicable European Directives  The declaration of conformity may be  consulted at http   www leica geosystems com ce     Conformity to         Hereby  Leica Geosystems AG  declares that the instrument is in compli     Conformity to e FCC Part 15  applicable in US    national regula  e Hereby  Leica Geosystems AG  declares that the instrument with Communication  tions side cover is in compliance with the essential requirements and other relevant    provisions of Directive 1999 5 EC and other applicable European Directives  The  declaration of conformity may be consulted at http   www leica geosys   tems com ce   Class 1 equipment according European Directive 1999 5 EC  R amp TTE  can  C     be placed on the market and be put into service without restrictions in  any EEA Member state   e The conformity for countries with other national regulations not covered by the  FCC part 15 or European directive 1999 5 EC has to be approved prior to use and  operation     FlexLin
6. ct has been dropped  stored  for long periods or transported        The target line of the visible laser can drift during the product lifetime  Inspect the  target line visually on a regular base  If necessary  visit an authorised Leica Service  Centre for adjustment     5 Operation    S The battery must be charged before using it for the first time     Turning on and off  the instrument                            FlexLine plus  Operation    15    FlexLine plus  Operation    Screen                Meas   Dist i S     Title of screen   Focus in screen  Active field  Status icons   Fields   Softkeys                50  0000 g  66  6667 o             ses EPERE PETE       Meas   Dist   Store   e    a  Status icons   b  Title of screen   c  Focus in screen  Active field   d  Fields   e  Softkeys    gt  Tapon an icon  field or tab to run  a function                 Icons Icon Description       Le ce  Displays the selected prism icon  the EDM measurement  A activity icon or the active laser pointer icon  For C amp T  Tapping    FA   the icon opens the EDM Settings screen     Displays the telescope position  face   or face II  or the  compensator status  on  off or out of range   For C amp T  Tapping  the icon opens the Level  amp  Plummet screen        Displays the keypad mode  numeric or alphanumeric   The icon  is displayed when an editable field is highlighted  For C amp T   Tapping the icon switches the keypad mode     Displays the communication port icon  RS232  Bluetooth or    U
7. e plus  Important Information about your Instrument 5    FlexLine plus  Instrument Components    2 Instrument Components       Instrument compo  ab c d  nents part 1 of 2     Ergofocus tele   scope                                         a   b     c     d     f   g     i     Optical sight   Detachable carrying handle with  mounting screw   Objective with integrated Electronic  Distance Measurement  EDM   Exit for  EDM laser beam   Vertical drive   On Off key   Trigger key   Horizontal drive   Display   Second keyboard   identical to first  keyboard   Optional for TSO2 plus       Instrument compo  j k  nents part 2 of 2                      j  Focusing telescope image  k  Eyepiece  focusing graticule  I  Battery cover   m  Serial interface RS232   n  Foot screw   o  Display   p  Keyboard                               002725_002       FlexLine plus  Instrument Components    FlexLine plus  Instrument Components    Instrument compo   nents part 1 of 2     Finefocus tele   scope     TSOX 009a    a                                                 Compartment for USB memory stick  and USB cable ports   Bluetooth antenna   Optical sight   Detachable carrying handle with  mounting screw   Electronic Guide Light  EGL    Objective with integrated Electronic  Distance Measurement  EDM   Exit for  EDM laser beam   Vertical drive   On Off key   Trigger key   Horizontal drive   Second keyboard    identical to first  keyboard   Optional for TSO6 plus   Optional for TS06 plus TSO9 plus       3
8. ight    CET  O ss  C588  O cts  ni Bae  I      oh  a OF mm  N ge  aos  SX  Oo    i  o0 J   lt     n  E  s  n   gt   n       J   UO  G  T  mall  N  ei      N           Geosystems    
9. n any  page  press the FNC Favourites key and select Coding      Station To enter station data and set the station     Set Hz To set the orientation to a user defined horizontal direction        Hz 4   Hz     To set the horizontal angle reading to the left  anticlockwise   or to the right  clockwise      FlexLine plus  Operation 19    FlexLine plus  Operation    EDM Settings EDM mode    20       P Precise     Fine measuring mode for highest precision measurements  with prisms  1 5 mm   2 ppm         P Precise  amp  Fast    P Tracking    Quick measuring mode with prisms  with higher measuring  speed and high accuracy  2 mm   2 ppm      For continuous distance measurements with prisms   3 mm  2 ppm         Tape    For distance measurements using Retro reflective targets   3 mm  2 ppm         P Long   gt 4 0 km     NP Precise       For long range distance measurements with prisms   5 mm  2 ppm   Available for instruments     For distance measurements without prisms  2 mm   2 ppm    gt 500 m  4 mm   2 ppm         NP Tracking    For continuous distance measurements without prisms   5 mm  3 ppm            Prism type                Round  GPR  Leica Const   0 0 mm   Leica Const    17 5 mm  Mini0  GMP111 0    Leica Const   0 0 mm   Jp Mini  SMP222    Leica Const    34 4 mm  360    GRZ4  Leica Const    23 1 mm  360  Mini GRZ101    Leica Const    30 0 mm  Tape  GZM  Leica Const    34 4 mm  Leica Const    34 4 mm  User 1   For any prism modes  the user can define two of their own    Use
10. r 2 prisms     Constants can be entered in mm in either Leica Const  or Abs     Const   For example     User prism constant    30 0 mm  Leica Const     4 4 mm  34 4    30   4 4   Abs  Const     30 0 mm       FlexLine plus  Operation    21       FlexLine plus  Operation 22    Menu Tree    FT Q Survey           Programs                    Station Setup  Survey  Stakeout  Tie Distance  COGO  Area  amp  DTM Volume             Remote Height  Traverse  Reference Line  Reference Arc               Reference Plane  Road 2D  Road 3D         Manage              Job  Fixpoints  Meas Data  Codes  Formats  Del Data  USB Stick          Transfer              Export  Import          Settings      I       Work  Regional  Data  Screen     EDM  Interface          Tools              Adjust  Startup  Info  Licence  PIN  Load FW       FlexLine plus  Operation    23    Total Quality Management  Our commitment to total customer satisfaction   Re Leica Geosystems AG  Heerbrugg  Switzerland  has been  certified as being equipped with a quality system which  7 O IVI meets the International Standards of Quality Management  and Quality Systems  ISO standard 9001  and Environmental  E iso 9001 1S0 14001    Management Systems  ISO standard 14001      Ask your local Leica Geosystems dealer sales representative for more informa   tion about our TQM program     Leica Geosystems AG  Heinrich Wild Strasse  CH 9435 Heerbrugg  Switzerland   Phone  41 71 727 3131    www leica geosystems com      when it has to be r
    