User Manual, Anybus Serial Server

image

Contents

1. Power Supply Requirements About the Anybus Serial Server 1 4 ElA 485 Interface The 6 pole RJ 12 connector features an ETA 485 interface This port can be used to connect to any equipment with an EIA 485 interface Signal Comments 1 A A Line 2 B B Line 3 Common Signal ground ji 4 Common Signal ground z 5 not used 6 not used EIA 232 Interface The 9 pole DSUB male connector on the Serial Server features a fully equipped EIA 232 interface This port can be used to connect to any equipment with an ETA 232 interface The Serial Server is configured as a DTE device The following signals ate available Signal Comments 1 CD Carrier Detect 2 Rx Receive 3 Tx Transmit 1 male 3 4 DTR DTE Ready 5 GND Signal ground 6 DSR DCE Ready 7 RTS Request To Send 8 CTS Clear To Send 9 RI Ring Indicator Ethernet Interface The Ethernet interface supports 10 100Mbps using a standard RJ45 connector About the Anybus Serial Server 1 5 Indicators a aaa ee EI EJ Ki Kai KI EI Ki LA Aa e Status Serial Link Serial Link A n YU bus Activity Activity SERIAL SERVER Link Link Ethernet LED State Function Module Status Off No power Green Module is running in normal mode Orange During boot up Serial Link Status Green flashing Serial Packet receive on either port Red fla
2. About the Anybus Serial Server 1 2 Mounting A Snap On B Snap Off y 2 Procedure 1 Snap the Serial Server on to the DIN rail as described on pictures above 2 Connect the Ethernet cable to the RJ45 connector 3 Connect the serial device to the 9 pole DSUB connector 4 Connect the Power Supply and apply power 5 Now you can start using the Serial Server use the Anybus IPconfig Utility to configure the IP address and other network settings See also e 2 1 IP Address Mac ID amp Default IP Address The default IP address of the Serial Server is 10 200 1 X where X is the last number of the MAC ID Can be found on the label on the device displayed in HEX format e _ _ PS CE 4 oie ad Mac ID See also e 2 1 IP Address Connectors Overview About the Anybus Serial Server 1 3 Description Comments 1 Power Supply See 1 3 Power Supply 2 ElA 485 Interface See 1 4 ElA 485 Interface 3 ElA 232 Interface See 1 4 ElA 232 Interface 4 Ethernet Interface See 1 4 Ethernet Interface Power Supply Signal Comments 24 Vin Voltage Range 9 32VAC DC 23 Vin Ground connection 22 not used 21 20 Digital in 2 Digital in 1 and Digital in 2 are internally tied together 19 Digital in 2 18 Digital in 1 17 Digital in 1 See also A 1 Technical Specification
3. Subnet mas k etc please contact your network administrator Field Details DHCP Setting Meaning Dynamic IP Use server assigned IP settings Static IP Use the settings described below Note Do not select Dynamic IP unless you have a DHCP server available on the network Host Name Here you can enter a hostname of your device IP Address The IP address Netmask The subnet mask Gateway The default gateway Primary DNS The primary Domain Name Server Secondary DNS The primary Secondary Name Server if it exists Press Save Settings to update your configuration Configuration 2 5 Serial Port Settings Configuration If you press the Configuration link you will be presented with the following view AnyBus Ta Server Serial Server Start Network Configuration Admin Serial Port ElA 232 Server Port Number Modbus Mode C On Of Silent Time l Manual Serial Settings Serial Port ElA 485 Server Port Number Modbus Mode r Silent Time M Manual Serial Settings The page is divided in two sections one for each serial port All fields exist for both ports except that the EIA 485 port has no flow control selection Field Description Serial Port Number The Serial Server answers on incoming connections on this IP port number The defaults are 2000 for ElA 232 port and 2001 for ElA 485 port Use these numbers when you connect from the Serial IP driver telnet or other
4. User Manual Anybus Serial Server Rev 1 20 1 HMS Industrial Networks AB a Germany 49 721 96472 0 ge sales hms networks com 4 4 Japan 81 45 478 5340 jp sales hms networks com Sweden 46 35 17 2920 sales hms networks com AHMIS U S A 1 773 404 3486 us sales hms networks com 4 y UK 44 0 1908 359301 uk sales hms networks com Table of Contents Table of Contents Preface About This Document How Fo Use This Document sss ceca a EE EEE E E P 1 Important User Torn italia P 1 Related Documenta lios alii alias P 2 Document Historia aa ecc P 2 Conventions Terminology A A A A ERE Chapter 1 About the Anybus Serial Server Gama 1 1 MIO aia 1 2 Mac TD See fault TP Add aii 1 2 Connector dea le Senile 28 ad dd ee 1 3 QUID A SERS Sa hap ag Rg beat BR 1 3 POESIA a A A E TROE EE O cts 1 3 FEA ASD TMN IE ai 1 4 nA E PE EIEEE EE NEE 1 4 Ethernet INITIO r na EA E E E R A EA E A A A S 1 4 TICA O ida beens 1 5 Chapter 2 Configuration TP Address A a a tad 2 1 About the Anybas Reonfig Un arca a iaa 2 1 Scanning for Connected Dt adas 2 1 Changing the IS Canos a la ocasion 2 2 Serial Port Settings Configuration PASSIONS RI a AEE aa Appendix A Technical Specification Preface About This Document How To Use This Document This document contains a general introduction as well as a description of the technical features pro vided by the Anybus Serial Server including the PC based c
5. a device double click on its entry in the list If you want to force a new scan for devices you can press the Scan button Anybus IPconfig JOE P sn ew 10101083 2552552550 0 000 mac E 00 30 11 FB 00 34 21 255255255 01 00 30 11 F8 10102141 2552552850 1010211 10 30 11 02058E Column Contents Comments IP The IP address SN The subnet mask GW The default gateway DHCP Dynamically assigned IP address On Off Version The version of the application software Type The product type MAC The MAC address of the Serial Server Printed on a label on the device in HEX format See also e 1 2 Mac ID amp Default IP Address Configuration 2 2 Changing the IP Settings To change the IP settings on a detected device double click on the device you want to configure in the list of devices This will open up a dialog where you can enter the desired IP configuration Configure 00 30 11 02 0A B6 Ethernet configuration IP address 10 10 10 83 DHCP C On Subnet mask 255 255 255 0 Ot Default gateway 10 10 10 1 Primary DNS 10 10 12 22 Secondary DNS D 0 0 0 Hostname SerialServer Password T Change password New password Cancel Field Contents IP Address The IP address of the Serial Server Subnet mask Mask network Default gateway The defaul
6. anybus com HMS America E mail us support hms networks com Phone 1 773 404 2271 Toll Free 888 8 Anybus Fax 1 773 404 1797 Online www anybus com HMS Germany E mail ge support hms networks com Phone 49 721 96472 0 Fax 49 721 964 7210 Online www anybus com HMS Japan E mail jp support hms networks com Phone 81 45 478 5340 Fax 81 45 476 0315 Online www anybus com Chapter 1 About the Anybus Serial Server General A serial server is a device that forwards data between a serial port and an Ethernet network It can be used to connect your serial devices to a LAN or Internet without any hardware modifications Together with a special software driver in a PC it can be used as a remote serial port PC applications designed to access devices on a normal serial port can access the remote serial server without any software modifications The LAN Internet network together with the serial server and driv er can be viewed as a long virtual serial cable ElA 485 Ethernet Anybus Serial Server Computer with Serial IP software Serial Device The Anybus Serial Server connects serial devices to Ethernet networks using the IP protocol family Some different types of serial devices supported are listed below Scanners Printers PLC s Data Collection Devices Telecommunications Equipment Data Display Devices Security Alarms and Access Control Devices Hand held Instruments Modems
7. application that can connect to a socket port For example if you connect to IP port 2000 your communication will go through the ElA 232 serial port Modbus Mode This is regarding fragmentation on received messages on the serial port If On it makes the low level serial driver to wait 3 5 characters standard Modbus message break time before it passes the received characters further Then it may be sent in one TCP IP packet to prevent fragmentation on the receive side The 3 5 char time is calculated from the current baud rate If Off you still can select the time in milliseconds to wait in silence before the received characters is passed to the serial server application in the NetBiter Typically 0 disables this feature If so characters received in about 10 milliseconds will be sent in each TCP IP packet This may mean less delay for each received byte but may mean more TCP IP overhead and maybe fragmentation of the serial packet Manual Serial Settings If you want to lock the settings on the serial port check this box This is useful for various rea sons For example if you connect with some application that doesn t do the remote serial port setup Normally your PC serial application does this through the Serial IP driver when you con nect to a Serial IP driver Com port If you use a program that doesn t set up the remote serial port the Serial Server defaults to 19200 baud rate 8 data bits No parity 1 stop bit Baudrat
8. e Sets the communication rate on the serial port Valid settings are 300 600 1200 2400 4800 9600 19200 38400 57600 and 115200 Character Format First field is how many bits are used for each character You can set 7 or 8 data bits Second field is for parity configuration Choose between No Even or Odd parity The third field is for how many stop bits to use There can be 1 or 2 Configuration 2 6 Field Description Flow Control For the ElA 232 port you can select if you want flow control handled by the UART If this is selected then transmit is automatically stopped continued when serial buffer is full available You can choose between NONE CTS RTS and XON XOFF NONE disables UART flow con trol If CTS RTS is selected the two UARTs involved uses two dedicated wires in the serial cable to control flow The Serial Server uses RTS when it wants to transmit and gets CTS back when it is clear to send Be sure to use a serial cable with these wires connected If XON XOFF is used the remote UART should send characters to signal its buffer state a This setting is available only if the Manual Serial Settings checkbox has been checked Press Save to update your configuration You will be asked to press a reboot button in the next view After about 20 seconds has passed you can press the start menu field up in the right corner to take you back to the start page Note The Server Port Number must match the value e
9. ntered in the Serial IP Driver Password Settings If you press the Admin link you will be presented with the following view AnyBus Serial Server Start Network Configuration Admin Set Password Login Password Confirm Password This screen allows you to change the administrator password for this device Enter the new password in the Password box and in the Confirm Password box Click Save Password to change the password Technical Specification Ethernet Interface 10Base T or 100Base TX IEEE 802 3 RJ45 Connector Serial Interface EIA 232 e EJA 232 with full modem control RTS CTS DCD DTR DSR RD e 300 115 200bps operation e 9 pole DSUB connector Power Supply Requirements e 9 32 VAC DC 17W Temperature Range e 0 55 C Operating e 25 75 C Non operating Humidity 5 93 RH non condensing Housing Material Grey plastic LEXAN 940 Self extinguishing according to UL94 VO Mounting Option DIN rail EN50022 CE Certification e According to EN 50 081 2 1993 and EN 61000 6 2 1999 Appendix A
10. onfiguration software The reader of this document is expected to be familiar with communication systems in general and the Microsoft Windows operating system Important User Information The data and illustrations found in this document are not binding We HMS Industrial Networks AB reserve the right to modify our products in line with our policy of continuous product development The information in this document is subject to change without notice and should not be considered as a com mitment by HMS Industrial Networks AB HMS Industrial Networks AB assumes no responsibility for any errors that may appear in this document There are many applications of this product Those responsible for the use of this device must ensure that all the necessary steps have been taken to verify that the application meets all performance and safe ty requirements including any applicable laws regulations codes and standards Anybus is a registered trademark of HMS Industrial Networks AB All other trademarks are the prop erty of their respective holders The examples and illustrations in this document are included solely for illustrative purposes Because of the many variables and requirements associated with any particular implementation HMS Industrial Networks cannot assume responsibility or liability for actual use based on these examples and illustra tions Warning This is a class A product In a domestic environment this product may cause
11. radio interfer ence in which case the user may be required to take adequate measures ESD Note This product contains ESD Electrostatic Discharge sensitive parts that may be damaged if ESD control procedures are not followed Static control precautions are required when handling the product Failure to observe this may cause damage to the product Related Documents About This Document P 2 Document name Author Document History Summary of Recent Changes v1 20 v1 20 1 Change Page s Changed layout Misc minor changes Revision List Revision Date Author s Chapter s Description 1 00 03 03 02 JOAK First released version 1 10 05 11 01 HACA Update for Modbus support etc 1 20 06 06 30 MASA Update to new design structure 1 20 1 06 11 17 PeP Updated layout misc minor changes About This Document P 3 Conventions 8 Terminology The following conventions ate used throughout this document Numbered lists provide sequential steps Bulleted lists provide information not procedural steps The term Serial Server is refers to the Anybus Serial Server ETA 485 is also commonly referred to as RS 485 EJA 232 is also commonly referred to as RS 232 Support HMS Sweden Head Office E mail support hms networks com Phone 46 0 35 17 29 20 Fax 46 0 35 17 29 09 Online www
12. shing Serial Packet transmit on either port Orange During boot up LAN Activity Green flashing Ethernet Packet received Red flashing Ethernet Collision detected Link 10 100 Off No Ethernet Link detected Green Ethernet network detected 10Mbps Orange Ethernet network detected 100Mbps Configuration IP Address About the Anybus IPconfig Utility Chapter 2 The Anybus IPconfig utility is a PC based configuration utility used to set TCP IP network settings in the Serial Server This utility has the ability to scan the Ethernet network for connected Anybus products and let the user set IP address net mask gateway DNS and hostname for each device Installation System Requirements 133MHz CPU or higher 5Mb of free hard disk space Microsoft Windows 95 98 ME NT 2000 XP Network Interface Ethernet Installation Procedure There are two methods to install the Anybus IPconfig utility either downloading it from the HMS website or use the installation CD ROM Using the CD ROM Run Setup AnybusIPconfig exe and follow the on screen instruc tions From website Download the self extracting installation package Setup AnybusIPcon fig exe from www anybus com and run it Scanning for Connected Devices When t he Anybus IPconfig utility is started it will scan the Ethernet network for Anybus products All detected devices will be presented in a list in the main window To alter the settings for
13. t gateway in the network Primary DNS The primary Domain Name Server Secondary DNS The primary Secondary Name Server if it exists Hostname Here you can enter a hostname of your device Password The default password for authentication of the new settings is admin New Password To change the password first check the Change password checkbox DHCP Setting Meaning On Use server assigned IP settings Off Use the settings described below Note Do not select the DHCP option unless you have a DHCP server available on the network Change Password Check this checkbox to enable the New password field Pressing Set will cause the Serial Server to reboot and apply the new settings To obtain the necessary information about IP address subnet mask etc please contact your network administrator Note You can test the new settings by opening a web browser and enter the IP you just selected If you selected DHCP and want to know what IP your device have been assigned you can do a new scan with the Anybus IPconfig utility to view the new network configuration information Configuration 2 3 Installing the Windows Driver Serial IP General Information To be able to use the Serial Server you need to install the Serial IP driver on a PC For installation in structions consult the Serial IP Quick Start available at the HMS website www anybus com Log In Open a web browser e g Internet Explorer and en
14. ter the IP address you have set on the Serial Server unit with the Anybus IPconfig utility Example If you entered the address 10 10 10 83 then you should enter the text below in the address field of the browser and press enter http 10 10 10 83 Now you should see the login screen see fig A OK OR TOK ute To be able to configure the serial server K NA you should enter admin in the user name box The default password is admin You can later change the default password to some A A a j SerialServer thing else This will be described later in the section Admin Mea E admin Y Password eo Note If you have problems to log in and you E Remember my password are sure that your password is correct make sure that Caps Lock is not enabled on your keyboard Welcome Page The welcome page of the Serial Server s Serial Admin Configuration 2 4 Network Settings If you press the Network link you will be presented with the following view AnyBus CS Server Serial Server Start Network Configuration Admin Network DHCP Dynamic IP Static IP Host name IP Address Netmask Gateway Primary DNS S Secondary DNS On this page you can view and change the TCP IP network settings in the device These settings are the same as the ones set by the Anybus IPconfig utility To obtain the necessary information about IP ad dress

Download Pdf Manuals

image

Related Search

Related Contents

Philips HTS9540 User Guide Manual Pdf  Thermal panel printer FT190S User's manual  Manuale d`uso  User Manual  Bedienungsanleitung - CONRAD Produktinfo.  WEST SYSTEM User Manual (Part 1)  Rheem 16 SEER High Efficiency - ECM Motor - Standard N Coil Sales Fact Sheet  S911 LOLA Operation Manual  QG Sixty IT.book - Support Sagemcom    