        User Manual User Manual
         Contents
1.    1   400045 1 Knob  thermostat  3   400044 1   Thermostat Fryer  regulating 200 400  4   400042 1   Combination Valve  Nat   4   400146 1   Combination valve  LP   5   400070 1   Tubing       fryer pilot  10   300031 3   Burner  Fryer  11   400043 1   Safety thermopile 18     12   4 3   Orifice       39  Nat   12   5 3   Orifice  52  LP   14   6 1 Thermostat  High limit 450F  15   7 1   Pilot 3  way                                               Not shown on drawing           www AvantcoEquipment com 21    EQUIPMENT    User Manual VANTCO          Frypot Parts for 3 burner Fryer             Key   PartNumber   Qty   Description                1   400037 1   Screen  Tube Fryer 3 burner  2   400036 1   Valve  Ball  3   200016 1   Tank  3 Burner   400038 2   Basket  Fryer 13    6       X6                              Not shown on drawing              22 www AvantcoEquipment com    EQUIPMENT    VANTCO User Manual    Frypot Parts for 5 burner Fryer                Key   PartNumber   Qty   Description          1   200036 1 Tank  5 Burner   2   400036 1   Valve  Ball      6 1 Screen  Tube Fryer 5 burner     7 2   Basket  Fryer 17    8        6                                 Not shown on drawing           www AvantcoEquipment com 23    EQUIPMENT    User Manual VANTCO    Leg Parts                      Key   PartNumber   Description  400108   20 Bolt       Long  400111      Lock Washer  400000 Leg  6                              Not shown on drawing              Caster Parts          40
2.   If the unit is to be set on non combustible flooring  such as a concrete slab  3  inches minimum toe room must be provided to prevent restriction of the air opening in the bottom of the unit         N WARNING    There must be adequate clearance between fryer s  and construction  Clearance must also be  provided in front for servicing and for operation     Minimum Clearances     From Combustible Construction From Non Combustible Construction  Sides 6 0  Rear 6 0    ALL ENTREE FRYERS SHALL BE INSTALLED WITH AT LEAST A 16 INCH SPACE BETWEEN  THE FRYER AND SURFACE FLAMES FROM ADJACENT EQUIPMENT     No additional side and rear clearance is required for service as the fryer is serviceable from the front         N WARNING    Improper ventilation can result in personal injury or death  Ventilation that fails to properly remove flue  products can cause headaches  drowsiness  nausea  or could result in death     Unit Must be installed under a ventilation Hood     All units must be installed in such a manner that the flow of combustion and ventilation air is not  obstructed  Provisions for adequate air supply must also be provided  Do NOT obstruct the bottom  front of the unit  as combustion air enters through this area  Be sure to inspect and clean the  ventilation system according to the ventilation equipment manufacturer   s instructions              Due to the variety of problems that can be caused by outside weather conditions  venting by canopies or wall  fans is preferred over 
3.  0 4 2 8 0 120 000 220                                        GAS SUPPLY AND BURNER INFORMATION    Supply pressure should be minimum of 4  W C  for natural gas or 10  W C  for propane  The fryer has one 3 4   NPT male connector located in the rear                                     Natural        4  W C           30 000    150 000    Manifold Number of Rate Each Total Rate 0    mode  Bumers Gas Type Pressure heat tube BTUs   Hour BTUs   Hour Orifice Size    Natural 4  W C  30 000 90 000  39  FF300 Main i  Propane 10  W C  30 000 90 000  52          Main  Propane          10  W C             Minimum supply pressure is 4  W C  for natural gas and 10  W C  for propane      Orifice sizes are for units installed at altitudes between 0 and 2000 feet above sea level        30 000          150 000             www AvantcoEquipment com    EQUIPMENT    VANTCO User Manual       INSTALLATION       NOTICE    Installation must conform with local codes  or in the absence of local codes  with the National Fuel  Gas Code  ANSI 2223 1  Natural Gas Installation Code  CAN CGA B149 1  or the Propane  Installation Code  CAN CGA B149 2  as applicable                 NOTICE    These installation procedures must be followed by qualified personnel or warranty will be void     Local codes regarding installation vary greatly from one area to another  The National Fire Protection  Association  Inc  states in its NFPA 96 latest edition that local codes are the    authority having  jurisdiction    when it 
4.  capacity is  described on the serial plate that is located inside the front door on the left side     Table of Contents    6616305 cecdvea dd ccessbaav eave TAAA 4  Nn Sta    310 2   50   2252                      5        6  3110 9  Cooking Hint         11  021030  0       11  SOIVIC  3 25 25 4 heise edi Ed Minds ist ape ed ee ed R 13        17  Fryer Warranty          25    Read these instructions carefully before attempting installation  Installation and initial startup should be  performed by a qualified installer  Unless the installation instructions for this product are followed by a  qualified service technician  a person experienced in and knowledgeable with the installation of commercial  gas an or electric cooking equipment   then the terms and conditions on the Manufacturer   s Limited Warranty  will be rendered void and no warranty of any kind shall apply     www AvantcoEquipment com 3    EQUIPMENT    VANTCO    User Manual    SPECIFICATIONS                                                                                                                                                                                                                               DIMENSIONS  FF500 Model Shown 0  i p  J     4  a  B  lt  lt  lt   Top View  l  j 1  E  Q f        Front View Side View  Model Width Depth Height Gas Connection Total Crated      A B 6 D E F 6 H l BTU hr   Weight  FF300 15 5 14 0 30 3 14 0 47 2 36 2 6 0 4 2 8 0 90 000 176  FF500 21 0 19 5 30 3 19 5 47 2 36 2 6
5.  casters supplied  a  connector complying with either ANSI 221 69 CSA 6 16 and a quick disconnect device complying  with ANSI 221 41 CSA 6 9  It must also be installed with restraining means to guard against  transmission of strain to the connector  as specified in the appliance manufacturers instructions            N WARNING    If disconnection of the restraint is necessary to move the appliance for cleaning  etc   reconnect it  when the appliance is moved to its original installed position            N WARNING    When this appliance is installed with casters  it must be installed with the casters supplied  a  connector complying with either ANSI 221 69 or CAN CGA 6 16 and a quick disconnect device  complying with either ANSI 221 41 or CAN1 6 9  It must also be installed with restraining means to  guard against transmission of strain to the connector  as specified in the appliance manufacturer s  instructions               WARNING    All fryers must be restrained to prevent tipping in order to avoid the splashing of hot liquid  The means  of restraint may be the manner of installation  such as connection to a battery of appliances or  installing the fryer in an alcove  or by separate means  such as adequate ties              6 www AvantcoEquipment com    EQUIPMENT    VANTCO User Manual       Step 3  Check Clearances and Ventilation    Select a firm  level location for your fryer  Leave clearance  whenever possible  so that access from the rear  is possible to permit cleaning
6.  respond to that procedure  calls for a vigorous scouring in the direction of the polish lines using a STAINLESS scouring pad in combination with a pow   ered cleanser  Heat tint action may be lessened by not applying or by reducing heat to equipment during slack periods     12 www AvantcoEquipment com    EQUIPMENT    VANTCO User Manual    SERVICE          NOTICE    Warranty will be void and the manufacturer is relieved of all liability if         A  Service work is performed by other than a qualified technician   OR   B  Other than genuine Avantcoreplacement parts are installed         N WARNING    Adjustments and service work may be performed only by a qualified technician who is experienced in   and knowledgeable with  the operation of commercial gas cooking equipment  However  to assure  your confidence  contact your Avantco Service Representative for reliable service  dependable advice  or other assistance  and for genuine factory parts           All units are adjusted at the factory  In case of problems in operation at initial installation  check type of gas  and manifold pressure and compare with information listed on the serial plate     A mill voltage circuit diagram is located inside the front door of the fryer  and also on page 16     CHECKING AND ADJUSTING MAIN BURNERS    The main burners should burn with a steady blue  flame  and the inner cone of the flame from each port  should be about 3 4  long  The flame from each main  burner should enter each heat tube wit
7. 0106    400107    Part Number   Description   400108   20 Bolt       Long   400111 4    Lock washer   400106 Caster  4     swivel with brake  400107 Caster 4     rigid                gt                                           not shown on drawing        24 www AvantcoEquipment com    EQUIPMENT    VANTCO User Manual       FRYER WARRANTY    All new Avantco Fryers are warranted to be free from defects in material and workmanship under normal use  and service for a period of one  1  year from the date of original installation or 15 months after shipment date  from the manufacturer  whichever occurs first  This is limited to the repair and replacement  including labor  charges  of defective parts and or assemblies  Labor  travel and mileage covered for the first year include  straight time labor charges and travel   charges within 100 miles  roundtrip     1  This warranty is limited to original installation of new Avantco Fryers for the original user in the United  States or Canada  This warranty is not transferable     2  This warranty does not apply to any equipment that has not been installed in accordance with the  directions published in the appropriate installation and operation manuals     3  Avantco will bear no responsibility or liability for any equipment which has been mishandled  abused   misapplied  misused  subjected to harsh chemical action  or external causes such as gas fluctuations   field modified without the approval of Avantco or by unauthorized personnel  i
8. AVANTCO User Manual       Floor Fryers    Models  FF300  FF500    Please read and keep these instructions  Indoor use only     www AvantcoEquipment com 1    EQUIPMENT    User Manual VANTCO       SAFETY PRECAUTIONS    Before installing and operating this equipment  be sure everyone involved in its operation is fully trained and  aware of precautions  Accidents and problems can be caused by failure to follow fundamental rules and  precautions     The following symbols  found throughout this manual  alert you to potentially dangerous conditions to the  operator  service personnel  or to the equipment        AN DANGER oe warns of immediate hazards that will result in severe injury or          This symbol refers to a potential hazard or unsafe practice that could result in  A WARNING injury or death            N CAUTION This symbol refers to a potential hazard or unsafe practice that could result in  injury  product damage  or property damage              NOTICE This symbol refers to information that needs special attention or must be fully  understood  even though not dangerous            N WARNING    FIRE HAZARD  FOR YOUR SAFETY    Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other  appliance     Keep area around appliances free and clear of combustibles     Purchaser of equipment must post in a prominent location  detailed instructions to be followed in the  event the operator smells gas  Obtain the instructions from the loca
9. PROCEDURE  IMMEDIATELY SHUT OFF THE GAS  SUPPLY UNTIL THE LEAK HAS BEEN CORRECTED        Open the burner compartment door and do the following   1  Turn thermostat to    OFF     2  Press down the knob of the combination gas  valve  turn it counterclockwise to the    PILOT     position  shown   and continue to press the knob  down                                                                                                                             3  While pressing the knob down  use a lit match to ignite the pilot  Continue to press the knob down for  about 30 seconds  If the pilot does not stay lit when the knob is released  repeat the lighting procedure  and keep the knob down longer  Adjustment of pilot flame may be necessary     4  When the pilot stays lit  turn the knob counterclockwise to the    ON    position  Do not press down on the  knob in this step     5  Do NOT turn the thermostat    ON    until the frypot is filled with oil or solid shortening     Once the frypot is filled with shortening  set the thermostat to the desired temperature     FILLING THE FRYPOT    1  Close drain valve completely before filling the frypot     2  When the fryer is new  fill the frypot with water and clean thoroughly  see    Weekly Cleaning    on page 12   in order to remove protective coatings and any foreign matter     3  The recommended solid shortening capacity ifod    beitrgdain the serial plate  which is  located inside the front door      4  Remove the basket support frame 
10. any type of direct venting  It is recommended that a canopy extend 6  past the  appliance and the bottom edge be located 6 6  from the floor  Filters should be installed at an angle of 45   or  more from the horizontal  This position prevents dripping of grease and facilitates collecting the run off  grease in a drip pan  unusually installed with a filter  A strong exhaust fan tends to create a vacuum in the  room and may interfere with burner performance or may extinguish pilot flames  Fresh air openings  approximately equal to the fan area will relieve such a vacuum  In case of unsatisfactory performance on  any appliance  check the appliance with the exhaust fan in the    OFF    position  Do this only long enough to  check equipment performance  then turn hood back on and let it run to remove any exhaust that may have  accumulated during the test     The exhaust fan should be installed at least 2 feet above the vent opening at the top of the fryer     This unit is not intended to be connected directly to an outside flue     www AvantcoEquipment com 7    EQUIPMENT    User Manual VANTCO    Step 4  Gas Connection       A 3 4  male NPT line for the gas connection is located near the lower right rear corner of the fryer  The serial  plate  located inside the front door of the fryer  indicates the type of gas the unit is equipped to burn  natural  gas or propane   The fryer should be connected ONLY to the type of gas for which it is equipped     A circuit diagram is located insi
11. comes to installation requirements for equipment           Step 1  Unpack    Great care has been taken during the packing and shipment of your Avantco Floor Fryer  However  if you notice any signs    of damage when unpacking the unit  please call  570  497 5477        e Do not remove any tags or labels until unit is installed and working properly     www AvantcoEquipment com 5    EQUIPMENT    User Manual VANTCO       Step 2  Install the Legs  or optional casters  and Restraints     A set of legs is packed with the fryer  Casters are available separately  Mounting fasteners are pre mounted on the base    1  Raise fryer sufficiently to allow legs or casters to be screwed into the baseplate  For safety     shore up     and support the fryer with an adequate blocking arrangement strong enough to support the load     2  Screw the four legs or casters to the plate on the bottom of the fryer  When casters have been ordered   the casters having a locking brake should be attached under the front of the fryer     Lower the fryer gently  Never drop or allow the fryer to fall     Use a level to make sure that the fryer is level  Each caster  or the tubular end of each leg  can be  screwed in or out to lower or raise each corner of the fryer     5  Attach restraints as required by local codes        NOTICE    Unit must be level to assure maximum performance  Improper leveling may void warranty           NOTICE    When this appliance is installed with casters  it must be installed with the
12. d affect burner  operating characteristics  A 1 8  tap to measure the manifold pressure is located on the combination gas  valve  which is on the burner manifold located directly below the burners inside the cabinet     Purge the supply line to clean out dust  dirt  or other foreign matter before connecting the line to the unit        It is recommended that an individual manual shutoff valve be installed in the gas supply line to the unit     Use pipe joint compound that is suitable for use with both natural and LP gas on all threaded connections        A CAUTION    ALL PIPE JOINTS AND CONNECTIONS MUST BE TESTED THOROUGHLY FOR GAS LEAKS   USE ONLY SOAPY WATER FOR TESTING ON ALL GASES  NEVER USE AN OPEN FLAME TO  CHECK FOR GAS LEAKS  ALL CONNECTIONS MUST BE CHECKED FOR LEAKS AFTER THE  UNIT HAS BEEN PUT INTO OPERATION  TEST PRESSURE SHOULD NOT EXCEED 14  W C           JN CAUTION    THIS APPLIANCE AND ITS INDIVIDUAL COMBINATION GAS VALVE MUST BE DISCONNECTED  FROM THE GAS SUPPLY PIPING SYSTEM DURING ANY PRESSURE TESTING OF THAT  SYSTEM AT TEST PRESSURES IN EXCESS OF 1 2 PSIG  3 45 kPa      The appliance must be isolated from the gas supply piping system by closing its individual manual  shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or  less than 1 2 psi  3 45 kPa               8 www AvantcoEquipment com    EQUIPMENT    VANTCO OLY am VETTEL    OPERATION       LIGHTING       AN CAUTION    IF YOU SMELL GAS DURING THE LIGHTING 
13. de the front door of the fryer     All Avantco equipment is adjusted at the factory  however  pilot height should be checked at installation and  adjusted  if necessary     For orifice sizes and pressure regulator settings  see the chart on page 4  If the fryer is being installed at over  2 000 feet altitude and that information was not specified when ordered  contact the appropriate authorized  Avantco Service Representative  Failure to install with proper orifice sizing will result in poor performance and may  void the warranty     If applicable  the vent line from the gas appliance pressure regulator shall be installed to the outdoors in  accordance with local codes or  in the absence of local codes  with the National Fuel Gas Code  ANSI  2223 1  Natural Gas Installation Code  CAN CGA B149 1  or the Propane Installation Code  CAN CGA   B149 2  as applicable     An adequate gas supply is imperative  Undersized or low pressure lines will restrict the volume of gas  necessary for satisfactory performance  A combination gas valve and pressure regulator  which is provided  with each unit  is set to maintain a 4  W C  manifold pressure for natural gas or 10 0  W C  manifold pressure  for propane gas  However  to maintain these conditions the pressure on the supply line  when all units are  operating simultaneously  should not drop below 7  W C  for natural gas or 11  W C  for propane gas   Fluctuations of more than 25  on natural gas or 10  on propane gas will create problems an
14. er fryer  3   100107 1   Panel  Fryer Front 3 burner  4   400035 1   Nameplate  Entree  6 100104 1 Panel  flue cover 3 burner  300032 1 Magnet  Door                              Not shown on drawing           18    www AvantcoEquipment com    EQUIPMENT    VANTCO          Cabinet Parts for 5 burner Fryer                                                       Part Number   Qty  100137    Description  Door  5 burner fryer                1  100138 1   Panel  Fryer Front 5 burner  400035 1   Nameplate  Entree  100135 1   Panel  flue cover 5 burner  300032 1   Magnet  Door                                 Not shown on drawing        www AvantcoEquipment com    19             EQUIPMENT    VANTCO          Gas Train Parts for 3 burner Fryer       k          Key   PartNumber   Qty   Description                                     1  5 1 Knob  thermostat  3   400044 1   Thermostat Fryer  regulating 200 400  4   400042 1   Combination Valve  Nat   4   400146 1   Combination valve  LP   5   400070 1   Tubing       fryer pilot  10   1 3 Burner  Fryer  11   400043 1   Safety thermopile 18     12   4 3   Orifice       39  Nat   12   5 3   Orifice  52  LP   14   6 1 Thermostat  High limit 450F  15   7 1   Pilot 3  way                                               Not shown on drawing           20    www AvantcoEquipment com    EQUIPMENT    VANTCO User Manual    Gas Train Parts for 5 burner Fryer                               Key   PartNumber   Qty   Description                                  
15. hout touching  the front of the frypot or the sides  top  or bottom of  each tube     Normal Flame    Blowing or Lifting Flames   too much air        Yellow Tips   too little air or too much gas        www AvantcoEquipment com 13    EQUIPMENT    User Manual VANTCO       CHECKING AND ADJUSTING PRESSURE REGULATOR  NOT PROVIDED     The combination gas valve and pressure regulator  not provided  is factory set at 4  W C   3 5            GFS18   for natural gas and 10  W C  for propane gas  To check the manifold pressure  do the following     1  Turn thermostat    OFF    and combination gas valve knob to the    PILOT    setting    2  Remove pressure tap plug from burner manifold located directly below the burners in the cabinet   3  Install a fitting appropriate to connect a manometer   4    Turn combination gas valve to    ON    position and thermostat to    ON     The burners will ignite  Be certain  that sufficient oil is covering the tubes     a    With burners on  read manometer     6  If the manometer does not read 4  W C   3 5    on GFS18  for natural gas  or 10  W C  for propane gas   adjust regulator     7  Remove regulator adjustment screw cap  see diagram on page 15      With small screwdriver rotate adjustment screw    CLOCKWISE    to increase or    COUNTERCLOCKWISE     to decrease pressure  Be sure to adjust with burners    ON        9  Turn thermostat    OFF    and set combination gas valve knob to    PILOT    position   10  Remove manometer and replace pressure tap 
16. ilure  a five minute purge period must be observed prior to re   establishing the ignition source              1  Shut off all gas   2  Wait five minutes     3  Follow the    Lighting    procedure described on page 9     AUTOMATIC PILOT VALVE    The Automatic Pilot Valve provides an automatic safety shutoff for the fryer when the pilot flame is  extinguished  When the pilot flame is burning  the valve is held open electromagnetically by the electrical  current from a thermopile in the pilot flame  When the pilot flame goes out  generation of current ceases and  the valve closes automatically     HIGH LIMIT CONTROL    Avantco Floor Fryers are equipped with a secondary heat control that prevents the oil temperature from rising above 450  F    Because of the accuracy tolerance of the sensor  the oil temperature may reach as high as 475   F      In the event the fryer shuts down due to this condition  the oil must be cooled to below 400  F before the pilot  burner can be re ignited  When the oil has cooled  use the    Lighting    procedure on page 9 to place the fryer  back in operation     10 www AvantcoEquipment com    EQUIPMENT    VANTCO User Manual    COOKING HINTS       USER TIPS      Smoking oil means that the temperature is too high  or that the oil has broken down    e Gum in frypot denotes a need for thorough cleaning  see    Weekly Cleaning    on page 12   Taste oil for quality  Replace it regularly   Poor oil cannot produce good food     CLEANING    Avantco equipment i
17. l gas supplier            N WARNING  BURN HAZARD    Contact with hot oil will cause severe burns  Always use caution  Oil at 200  F is more dangerous than  boiling water            N WARNING    In the event a gas odor is detected  shut down equipment at the combination gas valve and contact  the local gas company or gas supplier for service           NOTICE    Avantco Floor Fryers are intended for commercial use only  Not for household use   Warranty will be void if service work is performed by other than a qualified technician  or if other than  genuine Avantco replacement parts are installed     Be sure this Operator s Manual and important papers are given to the proper authority to retain for  future reference              2 www AvantcoEquipment com    EQUIPMENT    VANTCO OLY am VETOED       Congratulations  You have purchased one of the finest pieces of commercial cooking equipment on the  market     You will find that your new equipment  like all Avantco equipments  has been designed and manufactured to  meet the toughest standards in the industry  Each piece of Avantco equipment is carefully engineered and  designs are verified through laboratory tests and field installations  With proper care and field maintenance   you will experience years of reliable  trouble free operation  For best results  read this manual carefully     RETAIN THIS MANUAL FOR FUTURE REFERENCE     MODELS    This manual is for Avantco FF300  40 pound  and FF500  70 100 pound  tube style fryers  The
18. mproperly installed or  maintained  equipment damaged by flood  fire or other acts of God  or which have altered or missing  serial numbers     4  This warranty applies only to defects in parts and workmanship in equipment and not damage incurred  in shipping or handling     5  Ifthe equipment has been changed  altered  modified or repaired with parts not authorized or by a  nonqualified Avantco Service Technician  then Avantco shall not be responsible for warranty claim     6  Adjustments such as calibrations  leveling  tightening of fasteners or utility connections normally  associated with original installation are the responsibility of installer and not that of Avantco  Regular  maintenance and cleaning  shall be the responsibility of the customer     7  Avantco will bear normal labor charges incurred in the repair or replacement of a warranted piece of  equipment within 50 miles of an authorized service agent  Overtime  premium labor charges and travel  charges in excess of 100 miles round trip will not be covered by Avantco and will be the responsibility of  the person or firm requesting the service     8  Original purchased replacement parts will be warranted for 90 days from the parts invoice date  This  warranty is for parts cost only  does not include freight or labor charges     9  This warranty provides the exclusive remedy against Avantco relating to all Avantco  whether in contract or  in tort or under any other legal theory  and whether arising out of warrantie
19. n deposits       NOTE  Vibrations or shock caused by shaking or pounding baskets on top surface or by slamming door may  cause Hi Limit Control Switch to open  If this condition persists  additional cushioning may be added to the  rubber grommets supporting this control to absorb these shocks     www AvantcoEquipment com 15    EQUIPMENT    User Manual VANTCO    Wiring Diagram       Thermopile          Thermostat                      16 www AvantcoEquipment com    EQUIPMENT    VANTCO User Manual    PARTS          NOTICE    INSTALLATION OF OTHER THAN GENUINE AVANTCO PARTS WILL VOID THE WARRANTY ON  THIS EQUIPMENT              The serial plate is located inside the front door on the left side     Replacement parts may be ordered either through a avantco Authorized Parts Distributor or a AVANTCO  Authorized Service Agency     When ordering parts  please supply the Model Number  Serial Number  Part Number  and Description                             Index of Parts Diagrams  Page Number   Description  18 Cabinet Parts for 3 burner  19 Cabinet Parts for 5 burner  20 Gas Train Parts for 3 burner  21 Gas Train Parts for 5 burner  22 Frypot Parts for 3 bumer  23 Frypot Parts for 5 bumer  24 Legs and Casters             www AvantcoEquipment com 17    EQUIPMENT    VEEL VANTCO        050           Cabinet Parts for 3 burner fryer                                        8                                                              PartNumber   Qty   Description  1 2   100106 1 Door  3 burn
20. ntco neither assumes nor authorizes  any other person  purporting to act on its behalf  to modify or to change this warranty  or any other  warranty or liability concerning the goods     Customer Service  570  497 5477   Fax  888  388 6017       SANITATION SANITATION  SF ANSI 2 NSF ANSI 4       26 www AvantcoEquipment com    
21. plug   11  Replace adjustment screw cap     CHECKING AND ADJUSTING CALIBRATION OF THERMOSTAT    All thermostat controls are carefully calibrated at the factory  i e   the dial is properly set to control appliance  temperatures accurately   Only a qualified service technician should perform this adjustment     1  To check temperatures  use a thermocouple type temperature test instrument or reliable thermometer  Place the  thermocouple of test instrument or thermometer in the center of the frypot    2  Turn the control dial to the temperature setting requiring the greatest accuracy  Allow enough time for  temperature to stabilize  or until several temperature readings are identical     3  Recalibrate if setting and actual temperature differ by more than 10  F     4  Remove dial from dial shaft    B     Be careful that  dial shaft does not rotate in either direction at cREASI       which would change the dial setting           4 Se   DIAL    SHAFT     p              5  Hold dial shaft    B    steady and with a screwdriver  turn calibration screw    A    clockwise to decrease  the temperature  or counterclockwise to increase  the temperature  CALIBRATION            SCREW    A     6  Replace dial  Let the appliance operate until the    temperature has stabilized before a final check is  made to determine whether or not the calibration    has been corrected  1 4 TURN CHANGES    TEMPERATURE 18    INCRE 5     14 www AvantcoEquipment com    7  Once correct  seal the calibration screw 
22. rt  grease and product residue from stainless steel  use ordinary soap and water  with or without deter   gent  applied with a sponge or cloth  Dry thoroughly with a clean cloth  Never use vinegar or any corrosive cleaner     To remove grease and food splatter  or condensed vapors  that have baked on the equipment  apply cleanser to a damp  cloth or sponge and rub cleanser on the metal in the direction of the polishing lines on the metal  Rubbing cleanser  as  gently as possible  in the direction of the polished lines will not mar the finish of the stainless steel  NEVER RUB WITH A  CIRCULAR MOTION  Soil and burnt deposits that do not respond to the above procedure can usually be removed by rubbing  the surface with scouring pads  DO NOT USE ORDINARY STEEL WOOL  as any particles left on the surface will rust and further  spoil the appearance of the finish  NEVER USE A WIRE BRUSH  STEEL SCOURING PADS  EXCEPT STAINLESS   SCRAPER  FILE   OR OTHER STEEL TOOLS  Surfaces that are marred collect dirt more rapidly and become more difficult to clean  Marring also  increases the possibility of corrosive attack  Refinishing may then be required     Darkened areas  called  heat tint   sometimes appear on stainless steel surfaces where the area has been subjected to exces   sive heat  These darkened areas are caused by thickening of the protective surface of the stainless steel and are not harmful   Heat tint can normally be removed by the above cleaning techniques  but tint which does no
23. s  representations   instructions  installations or defects from any cause  Avantco shall not be liable  under any legal theory   for loss of use  revenue or profit  or for substitute use or performance  or for incidental  indirect  or  special or consequential damages or for any other loss of cost of similar type  The laws of some  jurisdictions limit or do not allow the disclaimer of consequential damages  If the laws of such a  jurisdiction apply to any claim by or against Avantco   NO limitations and disclaimers contained here shall  be the greatest extent permitted by law     10  The liability of Avantco is limited to the repair or replacement of any part found to be defective     11  THIS WARRANTY AND THE LIABILITIES SET FORTH HEREIN ARE EXCLUSIVE AND IN LIEU OF  ALL OF THEIR LIABILITIES AND WARRANTIES  EXPRESS OR IMPLIED  INCLUDING BUT NOT  LIMITED TO  IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR PARTICULAR  PURPOSE AND CONSTITUTES THE ONLY WARRANTY OF ENTREE WITH RESPECT TO THE  PRODUCT S   ENTREE LIABILITY ON ANY CLAIM     www AvantcoEquipment com 25    EQUIPMENT    User Manual VANTCO       INCLUDING BUT NOT LIMITED TO NEGLIGENCE  SHALL NOT EXCEED THE PRICE OF THE  EQUIPMENT THAT GIVES RISE TO THE CLAIM     12  If required by Avantco customer shall return to Avantco for examination any failed product or part to confirm  that the part has failed as a result of material or workmanship     13  The foregoing warranty is the Avantco Fryer warranty of Avantco  Ava
24. s constructed with the best quality materials and is designed to provide durable service  when properly maintained  To acheive the best performance  your equipment must be maintained in good  condition and cleaned daily  Naturally  the frequency and extent of cleaning depends on the amount and  degree of usage     Following daily and more extensive periodic maintenance procedures will increase the life of your equipment   Climatic conditions  e g   salt air  may result in the need for more thorough and more frequent cleaning in  order to keep equipment performing at optimal levels         N WARNING  BURN HAZARD    If necessary to move the fryer for cleaning  etc   drain oil first to avoid death or serious injury            N WARNING    If disconnection of the restraint is necessary to move the appliance for cleaning  etc   reconnect it  when the appliance is moved toitsoriginally installed position              DAILY CLEANING   1  Turn combination gas valve knob to    PILOT    position    2  Place suitable container under the drain and drain the frypot completely    3  Remove the basket support frame and flush out any sediment remaining in the frypot with a little hot oil   4  Wipe off the basket support frame and the inside of the frypot with a clean cloth           CAUTION  SOME AREAS OF THE FRYPOT MAY BE HOT              www AvantcoEquipment com 11    EQUIPMENT    OLY am VEEL VANTCO       5  Close drain valve and strain the oil back into the frypot through several thicknes
25. ses of cheesecloth  or  filter it back using a filter machine     6  Replace the basket support frame   7  Add oil or solid shortening to raise oil level to mark on rear of frypot   8          resume cooking  turn the combination gas valve knob to    ON    position     WEEKLY CLEANING  1  Follow steps 1 through 4 of the Daily Cleaning procedure  see previous section    2  Close drain valve and fill frypot with a solution of warm water and a strong detergent or other strong cleanser     empest__ Tough on grease  Tough on carbon  Tempest deep fat fryer cleaner pow   Deep Far Fryer Cleaner der offers thorough boil out of encrusted grease and grime     Relight the fryer and bring the solution to a gentle boil for at least five minutes      gt     Turn off main burners and let the solution stand until the gum deposits are softened and the carbon spots  and burned grease spots can be rubbed off     Scrub the frypot walls and heat tubes  then drain out frypot and rinse it with clean water   Refill the frypot with clean water and boil again   Turn off gas and drain and rinse well until clean     Wipe dry with a clean cloth     O            Refill as specified in the    Filling the Frypot    section  see page 10      MONTHLY CLEANING   1  Perform the Weekly Cleaning procedure  see previous section    2  Clean around burner and orifices if lint has accumulated    3  Visually check that burner carry over ports are unobstructed     CLEANING STAINLESS STEEL SURFACES    To remove normal di
26. when filling the frypot with solid shortening     When solid shortening is used  be careful not to bend  break  or twist the thin capillary wires of the  sensing elements located in the frypot     6  Pack solid shortening into the zone below the tubes  all spaces between the tubes  and at least an inch  above the top of the tubes before lighting the fryer  If any air spaces are left around the heat tube  surfaces when the heat is turned on  the tube surfaces will become red hot  burn the solid shortening   weaken the frypot  and could result in a fire     www AvantcoEquipment com 9    EQUIPMENT    User Manual VANTCO       A CAUTION    NEVER ATTEMPT TO MELT A SOLID BLOCK OF SHORTENING ON TOP OF THE HEAT TUBES   NEVER START THE BURNERS WHEN THE FRYPOT IS EMPTY        7  To prevent burning or scorching the solid shortening  keep the thermostat set at the lowest temperature  until all the solid shortening between and above the tubes has been melted  Additional solid shortening  can then be added until the desired frying depth has been reached     8  Replace the basket support frame over the frypot heat tubes     SHUTDOWN PROCEDURE    Standby  Turn knob on the combination gas valve to the    PILOT    position  At this setting  only the pilot burner  will remain ignited     Complete Shutdown  Turn knob on the combination gas valve  then press down on the knob and continue to  turn to the    OFF    position     RELIGHTING        N WARNING    In the event of a main burner ignition fa
27. with  glyptol     EQUIPMENT    VANTCO User Manual       CHECKING AND ADJUSTING AUTO SAFETY PILOT    The pilot flame should surround the thermopile for 1 2   It must be large and sharp enough to cause the  thermopile to glow a dull red  or sufficient to hold the safety valve open     1  Remove pilot adjustment cap                     Pressure Adjustment  Under this Cap                                                                                                          Pilot Adjustment re  Under this Screw          2  Adjust pilot key to provide properly  sized flame shown in diagram B     Diagram A shows an improperly  adjusted pilot       3  Replace pilot adjustment cap     TROUBLESHOOTING    Problem Likely Cause          Gas supply to unit off    Combination gas valve is in    OFF    or    PILOT    position   Pilot not ignited    Thermostat not    ON        Combination gas valve is in    OFF    position   Pilot gas not adjusted properly    Gas supply to unit off    Bad thermopile    Dirty thermopile connections at combination gas valve or high limit   Clogged orifice    Draft condition    Air in gas line    Improper ventilation system    Unit connected to wrong gas supply   Pressure not adjusted correctly    Pilot gas not adjusted correctly     Wrong size orifices    Connected to wrong gas supply   Pressure not adjusted correctly   Flue obstructed     Burners do not come on       Pilot will not stay ignited       Pilot produces carbon deposits       Burners produce carbo
    