1. K5903500 EONIS 17 06 2014 LLL 1 7 Important information 32 Ambient Light Compensation Yes preset values in OSD ALC Front sensor es Maximum luminance 440 cd m typical DICOM calibrated luminancs Response ime Tr Tf Housing color Black Silver Video input signals DisplayPort DVI USB ports 1 upstream 2 downstream Use standard ED ower save mode Yes ower management DPMS 165 MHz SD languages English French German Spanish Italian Dutch Japanese Traditional Chinese Simplified Chinese Korean 376 x 591 7 x 201 33 mm portrait WxH Dimensions w o stand W x H 376 x 484 x 75 93 mm portrait Ix OX OF o UO vu v 03108 g 3 E o o o 2 2 o z gt o ied 2 EL W x H 584 x 667 x 272 mm x Jg O3 2 o o o 5 D O Q amp re D 7 kg 25 kg 12 4 kg o 100 0 5 0 mm 5 20 45 45 ilt wivel ivot VESA 100 mm z lt stand creen protection Certifications CE MDD 93 42 EEC class product CE 2004 108 EC IEC 60601 1 2005 ANSI AAMI ES60601 1 2005 R 2012 C1 2009 R 2012 A2 2010 R 2012 CAN CSA C22 2 No 60601 1 2008 DEMKO EN 60601 1 2006 EN 60601 1 2 2007 KC VCCI FCC class B ICES 001 Level B FDA Class device RoHS Supplied accessories User Guide Cable routing strap Video cables 1 x DVI 1 x DP Main cables UK European CEBEC KEMA or USA UL CSA adaptor plug NEMA 5 15P SB 2 0 cable Cleaning
2. keys to move through the sub menus change values or make selections 2 To go into a submenu or confirm adjustments and selections use the Menu Enter key 12 _ K5903500 EONIS 17 06 2014 5 Advanced operation 5 ADVANCED OPERATION 5 1 Video input source selection About video input source selection By default your Eonis display automatically detects and shows the connected video input source How ever when for instance more then one video input source is connected it may be needed to manually select the input source to be displayed The available video input source selections for your display are Auto This is the default setting and will automatically detect and display the connected video input Source e DVI This setting will display the video connected to the DVI input e DisplayPort This setting will display the video connected to the DisplayPort input To select a video input source 1 Bring up the OSD main menu 2 Navigate to the nput Selection menu 3 Select one of the available video input sources 5 2 Luminance adjustment About luminance adjustment The luminance of your Eonis display is adjustable over a predefined range When you change the lumi nance the display will adjust its backlight to reach the target To adjust the luminance 1 Bring up the OSD main menu 2 Navigate to the Adjustments menu 3 Enter the Luminance submenu 4 Set a luminance value as desir
3. Bring up the OSD main menu 2 Navigate to the Adjustments menu 3 Enter the Gamma submenu 4 Select one of the available gamma functions 5 4 Ambient light reading room selection About ambient light reading rooms The available ambient light reading rooms for your display are e Dark Room Corresponds to light conditions in dark diagnostic reading rooms This setting has the lowest maximum ambient light Office Corresponds to light conditions in office rooms Operation Room Corresponds to light conditions in operating rooms This setting has the highest maximum ambient light e QAWeb This setting will be automatically selected when ambient light conditions are defined by Med iCal QAWeb To select an ambient light reading room 1 Bring up the OSD main menu 2 Navigate to the Adjustments menu 3 Enter the Ambient Light submenu 4 Select one of the available reading rooms and confirm 5 5 White point selection About white point selection This setting allows you to modify the display white point used as reference for all other colors to be dis played The available white point settings for your display are Native The native unmodified color temperature of the LCD panel 6500K sRGB Corresponds to a color temperature of 6500 Kelvin D65 e QAWeb This white point setting will be automatically selected when white point is defined by MediCal QAWeb K5903500 EONIS 17 06 2014 5 Advance
4. e Strong alkalis lye strong solvents Acid Detergents with fluoride Detergents with ammonia Detergents with abrasives e Steel wool Sponge with abrasives Steel blades Cloth with steel thread CAUTION Take care not to damage or scratch the front glass or LCD Be careful with rings or other jewelry and do not apply excessive pressure on the front glass or LCD CAUTION Do not apply or spray liquid directly to the display as excess liquid may cause damage to internal electronics Instead apply the liquid to a cleaning cloth K5903500 EONIS 17 06 2014 __ SSS 19 6 Maintenance 20 K5903500 EONIS 17 06 2014 7 Important information 7 IMPORTANT INFORMATION 7 1 Safety information General recommendations Read the safety and operating instructions before operating the device Retain safety and operating instructions for future reference Adhere to all warnings on the device and in the operating instructions manual Follow all instructions for operation and use Electrical Shock or Fire Hazard To prevent electric shock or fire hazard do not remove cover No serviceable parts inside Refer servicing to qualified personnel Do not expose this apparatus to rain or moisture Modifications to the unit Do not modify this equipment without authorization of the manufacturer Type of protection electrical Display with external power supply Class equipment Degree of safety flammable an
5. s s 2 e Lc ore Lae Lii v y ee eee a ed kde dcr ea velle 12 4 3 Bringing up the OSD menus sseessssssssuuullllle s eee esee a e 4 sheet eee nnns 12 4 4 Navigating through the OSD menus ssssssssssssssssss mme emen 12 S Advanced operatlODii ieoeiuioe o ier e RR IRA sect sees Aa X RAN MERE R Ra ST Rap E US ILE UEE 13 5 1 Video input source selection ssssssssssssssssssssssssssssssss sess s nnn 13 5 2 Luminance adjustment 2 2 2 cece ee cccce EEEa ee TEE ar EEEE beeen eegaadeceseeebentebeneeae 13 5 3 Gammia selectlori sna RUD RO dee ty iaa eE en Eh Yasin cd ede RR aan ee 13 5 4 Ambient light reading room selection cece cece eee ence nnn 14 5 5 White point selection c cece cece cee cence ceed denen tenet e eee e nent hs e n n rrr 14 5 6 OSD menudang age erar iaa amp xe e Eh awn ee add aa aaah ee 15 5 7 Orlentatioriz oor taxe DO b E Ron c aa aed de Ente uta aao d ie 15 5 8 DPMS mode 7 Cree eT ER a ee I AY XR LIS Hr ae Dre 16 5 9 Power sstatus LED is ene us i ae Dis dea ege eed Ode cune eeu a sien 16 5 10 Self calibration frequency aorar eea eE eH e semen sen 16 SM NACER x 17 6 Maintenance aeneon sa aono 3003804 I3 REA ERBARSBREIRRASR RARE ARIA SIR SESR NA DTE DERT ARIA EAO 19 6 1 Cleaning instructions aeter eR ER he reet eve tanh ve Y NER RR Eh th dete tA Gud Ate ve T UTI 19 7 Important information 2 irr ic ei trees ids E ERESARIDRRSRMP
6. 1 Bring up the OSD main menu 2 Navigate to the Adjustments gt Settings gt Power Save menu 3 Enter the DPMS submenu 4 Select On or Off as desired and confirm 5 9 Power status LED About the power status LED By default the power status LED has the following behavior e Green Display is on Blinking green Display is entering standby power saving mode Orange Display is in standby power saving mode e Off Display is disconnected from the mains power This default behavior can be changed so that the power status LED is also off when the display is on or when the display is entering standby power saving mode To change the behavior of the power status LED 1 Bring up the OSD main menu 2 Navigate to the Adjustments gt Settings menu 3 Enter the Power Status LED submenu 4 Change the behavior of the power status LED as desired and confirm q The orange standby power saving state of the LED is not influenced by this setting So when the display is in standby power saving mode the LED will turn orange even if it was switched off by this setting 5 10 Self calibration frequency 16 About self calibration The front sensor of your Eonis display measures the output luminance of your screen and allows the display to automatically stabilize its luminance for maximum image quality over the displays lifetime This self calibration is done at an adjustable predefined frequency K5903500 EONIS 17 06 201
7. applies strict selection criteria for its LCD panels To learn more about LCD technology and missing pixels consult the dedicated white papers available at www barco com healthcare Maximize quality assurance QAWeb guarantees optimum and stabilized image quality in every private practice The front sensor on the Eonis works seamlessly with QAWeb to ensure a consistent image over time It automatically stabilizes the image from the moment you switch on the display What s more QAWeb provides you with instant feedback on the status of the display K5903500 EONIS 17 06 2014 11 4 Daily operation 4 2 On Off switching To switch your display on or off 1 Shortly press the Standby key 4 3 Bringing up the OSD menus About the OSD menu The OSD menu allows you to configure different settings to make your Eonis display fit your needs within your working environment Also you can retrieve general information about your display and its current configuration settings through the OSD menu To bring up the OSD menu 1 While the display is switched on press the Menu Enter 9 key As a result the OSD main menu comes up in the middle of the screen If no further actions are taken within the following 10 seconds however the OSD menu will disappear again 4 4 Navigating through the OSD menus To navigate through the OSD menus 1 Use the Right Down and Left Up
8. cloth This adapter s is a forming part of the medical device Manufacturer BridgePower Corp BPM060S24F089 Input 100 240 V AC 50 60 Hz 1 5 A Output 24V DC 2 7 A QA software MediCal QAWeb amp QAWeb PP K5903500 EONIS 17 06 2014 7 Important information Warranty 3 years Operating temperature 10 C 35 C Storage amp transport 20 C 60 C temperature Operating humidity 20 85 non condensing Storage amp transport humidity 5 95 non condensing Operation altitude 3000 m Storage amp transport altitude 5500 m Operating pressure 70 kPa 106 kPa Storage amp transport pressure 50 kPa 106 kPa K5903500 EONIS 17 06 2014 __ SSS 3 7 Important information 34 K5903500 EONIS 17 06 2014 A Troubleshooting A TROUBLESHOOTING A 1 Troubleshooting General If you experience trouble with the LCD display refer to the following troubleshooting If the problem per sists please contact your local dealer or our service center Problem No image appears on the screen Push the standby button e Check if all I O and power connectors are correctly connected as described in the installation section Make sure the pins of the connectors are not crooked or broken Problem Partial image or incorrectly displayed image Check to see if the resolution of your computer is higher than the resolution of the display e Re configure the resolution of your computer t
9. of the video input is landscape If you use the display in portrait ee of the computer CAUTION Do not try to pivot your display when attached to the stand Trying to do so could cause serious damage to your display and its stand It is expected behavior to have some movement between the LCD panel and the front bezel of the display This will have no impact on the functionality or reliability of the display K5903500 EONIS 17 06 2014 LL T7 3 Display installation 3 2 Connecting the cables To connect the cables 1 Connect one or more of the video input connections of your display DVI or DisplayPort to the corre sponding video outputs on your computer or any other video device 2 If you want to make use of the display s USB downstream connectors then connect your workstation with the display s USB upstream connector by means of the supplied USB cable 3 Connect the supplied external DC power supply to the 24 VDC power input of your display 4 Plug the other end of the external DC power supply into a grounded power outlet by means of the proper power cord delivered with your display f i az mm J a f 3 gog E EJ yu lj e o o o60 Q Image 3 2 3 3 Kensington security slots To make use of the Kensington
10. security slots Your Eonis display has 2 Kensington slots available which allow you to secure the display to a desk or any other fixed object 8 K5903500 EONIS 17 06 2014 3 Display installation Image 3 3 3 4 VESA mount installation yN CAUTION Use suitable mounting apparatus to avoid risk of injury To mount the display on a VESA arm The display panel standard attached to a stand is compatible with the VESA 100 mm standard 1 Unscrew the four fixation screws to detach the panel from the stand 2 Use 4 M4 screws to attach the panel to a VESA approved arm Please make sure that the length of the screws is 10mm VESA plate thickness tolerance of 1 mm K5903500 EONIS 17 06 2014 3 Display installation 10 a Image 3 4 CAUTION Use an arm that can support a weight of at least 12 kg 26 50 Ibs Failure to do so could make the panel fall causing serious injury to a child or adult and serious damage to the equipment CAUTION Never move a display attached to an arm by pulling or pushing the display itself Instead make sure that the arm is equipped with a VESA approved handle and use this to move the display Please refer to the instruction manual of the arm for more information and instructions K5903500 EONIS 17 06 2014 4 Daily operation 4 DAILY OPERATION 4 1 Recommendations for daily operation Optimize the lifetime of your display Enabli
11. the device Electromagnetic emissions The Eonis is intended for use in the electromagnetic environment specified below The customer or the user of the Eonis should assure that it is used in such an environment Compliance Electromagnetic environment Guidance RF emissions Group 1 The Eonis uses RF energy only CISPR 11 for its internal function Therefore its RF emissions are very low and are not likely to cause any interference in nearby electronic equipment K5903500 EONIS 17 06 2014 LL 25 7 Important information 26 Guidance CISPR 11 in all establishments including Harmonic emissions Class D domestic establishments and those directly connected to the IEC 61000 3 2 _ public low voltage power supply Voltage fluctuations flicker Complies network that supplies buildings emissions used for domestic purposes IEC 61000 3 3 This Eonis complies with appropriate medical EMC standards on emissions to and interference from sur rounding equipment Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation Interference can be determined by turning the equipment off and on If this equipment does cause harmful interference to or suffer from harmful interference of surrounding equipment the user is encouraged to try to correct the interference by on
12. transmitter manufacturer 28 K5903500 EONIS 17 06 2014 7 Important information 7 5 Explanation of symbols Symbols on the device On the device or power supply you may find the following symbols nonrestrictive list C Indicates compliance with the Directive 93 42 EEC as Class device C Indicates compliance with the Directive 93 42 EEC as Class II device FE Indicates compliance with Part 15 of the FCC rules Class A or Class B oil Indicates the device is approved according to the UL regulations ls Indicates the device is approved according to the UL regulations for Canada and US ce AOG Indicates the device is approved according to the UL Demko regulations Indicates the device is approved according to the CCC regulations Indicates the device is approved according to the VCCI regulations lt A Indicates the device is approved according to the KC regulations Indicates the device is approved according to the BSMI regulations Indicates the USB connectors on the device Indicates the DisplayPort connectors on the device Indicates the manufacturing date HORNOS Indicates the temperature limitations for the device to safely operate within specs x x b 6 Values for xx and yy can be found in the technical specifications paragraph K5903500 EONIS 17 06 2014 LLL 29 7 Important information 30 Indicates the device serial no Warning dangerous voltage Caution Consult th
13. 4 5 Advanced operation 1min 1hr 3hr 24hr Never e QAWeb This setting will be automatically selected when the self calibration frequency is defined by MediCal QAWeb To adjust the self calibration frequency 1 Bring up the OSD main menu 2 Navigate to the Adjustments gt Settings menu 3 Enter the Self Calibration Frequency submenu 4 Select one of the available frequency presets 5 11 Factory reset About factory reset A factory reset allows you to fully restore the display to its original factory setting To perform a factory reset 1 Bring up the OSD main menu 2 Navigate to the Adjustments gt Settings menu 3 Enter the Factory Reset submenu 4 Select Yes or No as desired and confirm K5903500 EONIS 17 06 2014 __ ST 5 Advanced operation 18 _ FK5903500 EONIS 17 06 2014 6 Maintenance 6 MAINTENANCE General maintenance information The Eonis does not require any scheduled maintenance or calibration activities We recommend to use QAWeb with the Barco default tests and frequencies to calibrate and maintain the display or return the display to a Barco approved maintenance organization In any case of doubts contact the Barco Health care Division 6 1 Cleaning instructions To clean the display Clean the display using a sponge cleaning cloth or soft tissue lightly moistened with plain water Do not use following products e Alcohol solvents at higher concentration gt 5
14. Eonis User Guide 21 inch clinical display K5903500 03 BARG 17 06 2014 Visibly yours Barco nv President Kennedypark 35 8500 Kortrijk Belgium Phone 32 56 23 32 11 Fax 32 56 26 22 62 Support www barco com esupport Visit us at the web www barco com Printed in Belgium Table of contents TABLE OF CONTENTS T WOICODIGL uocis dee a ed ot Na EA ERI ra DL NIME RULES HM A 3 1 1 About the product etd ARR aap de Boia E RARUS DR ae ete IR NER 3 1 2 Whats the BOX ss 23 52 scant euo Det E coe 147 ees ca PONE S Ra Babel daa dave needs tn COD RR 3 2 Parts controls and connectors cnet cia eia inh RR RU EENNEE EARN EEMNUYENA 5 AT TESI E BGB 5 MEUS 6 3 Displ y installation voix sic nce ices wa eser ean erue tae va wake usps eb ig Vda EE XE EE Een eee EN 7 3 1 Adjusting the display position sssri 0 ccc ee eect nett OEE TA me e nnn 7 3 2 Connecting the Cables ioo poe tiie ade LUE EHE tha eget dd weaned yaad pt Ae dd dee 8 3 3 Kensington security Slots siasio iei bn UE EE de LEDs exte bbs p PER RR EE LO LA EE 8 3 44 VESA mountinstallation a stage deddentite b ERR PEEL be e Feb dp DER RR EE A ATAT 9 A gt Daily OD Ghat OND exe ae xueshn s s Mas MARE ERG MEER ERN a a av ag CENE ARR M IE EE 11 4 1 Recommendations for daily operation 0 cece cece eee eee mens 11 4 2 On Off switching
15. HR i CEIP ALAD 388 E p E A Fit ATER 5 REPERI n AE Teh E ES GR FHRRBR EFUP IRS Barco Gu Pfr3 amp FH SEFUP E S ESM RE MANA RASS AF h XB EAR EB THE BI ES EAR BU Ar All Electronic Information Products EIP that are sold within Chinese Mainland must comply with the Electronic Information Products Pollution Control Labeling Standard of Chinese Mainland marked with the Environmental Friendly Use Period EFUP logo The number inside the EFUP logo that Barco uses please refer to the photo is based on the Standard of Electronic Information Products Environmental Friendly Use Period of Chinese Mainland 10 K5903500 EONIS 17 06 2014 7 Important information 7 3 Regulatory compliance information Indications for use This display is an AMLCD display designed for viewing medical X ray images This unit should not be used near patients where patients are likely to be in unconscious condition and should be kept outside of 1 83 m perimeter and 2 29 m vertical FCC class B This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference re ceived including interference that may cause undesired operation This device has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable prote
16. OHSHTASE rh Es f BP Ml SE MCV E H EYE RJ iU SERT BS SEG H According to the China Administration on Control of Pollution Caused by Electronic Information Products Also called RoHS of Chinese Mainland the table below lists the names and contents of toxic and or hazardous substances that Barco s product may contain The RoHS of Chinese Mainland is included in the MCV standard of the Ministry of Information Industry of China in the section Limit Requirements of toxic substances in Electronic Information Products SE HERB 5 5 4 amp a8 Um cx Component name e aou ET and elements ADE 2 a a Rom Cr6 NE MN Printed Circuit Assemblies LCD panel External Cables K5903500 EONIS 17 06 2014 LLL 23 7 Important information 24 34M 5 5 ABBAS Y acd Component name Hazardous substances and elements t KMR ZRKA ZR Cd Cr6 A ED AX ER Internal wiring BO Eqs a ERE Power Supply Unit IA Es Fan HB ii BAB CD manual O RRBZASRSVREZHMEMAY RMA PHS SH SIT 11363 2006 MEMEM MSE RUT O Indicates that this toxic or hazardous substance contained in all of the homogeneous materials for this part is below the limit requirement in SJ T11363 2006 X KRRBZASASYWRELEGREHR YDAMA PHS SHH SIT 11363 2006 RMEMEN RRR Se BR X Indicates that this toxic or hazardous substance contained in at least one of the homogeneous materials used for this part is above the limit requirement in SJ T11363 2006 f rh ELA RH E B3 48 IN E
17. SUDPRURRERRAN NEQRPNUU nenun 21 Al Safety Information dde e bb EE Ed dase bee ee RR DUE 21 7 2 Environmental information rn reb YR ne ee v eR dddidex kde 23 7 3 Regulatory compliance information sess mme nnn 25 TA EMG notlee seo dd t p EE RE e dear aee aia ad ed Eu 25 7 5 Explanatiorrof symbols 224r mr ebbe Eua iic ma tae beber ded didis rib iidea 29 7 6 kegal disclaimer 5t dar rb RE deen bete add ad ed an 31 T Jechrical specificatlons i acere rema tuned Ove d IS te ads eee Lee ede 31 Ax Troubleshooting geereeteee c a ae iiia a a 35 AW Troubleshooting RE 35 A2 Warning sighals ooo EEEE AREE AAS EEE AEAEE AOADA EE AA AOAIE ATAS 35 K5903500 EONIS 17 06 2014 1 Table of contents 20 K5903500 EONIS 17 06 2014 7 Welcome 1 WELCOME 1 1 About the product Consistent image quality The Eonis display presents crisp razor sharp high contrast images To guarantee image consistency at all times it features a unique front sensor that automatically aligns image quality every time the display is turned on This image consistency enhances collaboration images always appear exactly like they are supposed to on every display which spurs confident clinical decisions Furthermore specialists looking at X ray images will appreciate the built in DICOM settings One click quality assurance Like Barco s entire medical display range the Eonis display line comes with Barco s onli
18. a suojamaadoituskoskettimilla varustettuun pistorasiaan K5903500 EONIS 17 06 2014 7 Important information Norway Apparatet ma tilkoples jordet stikkontakt Sweden Apparaten skall anslutas till jordat uttag 7 2 Environmental information Disposal Information Waste Electrical and Electronic Equipment A E This symbol on the product indicates that under the European Directive 2012 19 EU governing waste from electrical and electronic equipment this product must not be disposed of with other municipal waste Please dispose of your waste equipment by handing it over to a designated collection point for the recycling of waste electrical and electronic equipment To prevent possible harm to the environment or human health from uncontrolled waste disposal please separate these items from other types of waste and recycle them responsibly to promote the sustainable reuse of material resources For more information about recycling of this product please contact your local city office or your municipal waste disposal service For details please visit the Barco website at http www barco com en AboutBarco weee Turkey RoHS compliance A mmmm Turkiye Cumhuriyeti AEEE Y netmeli ine Uygundur Republic of Turkey In conformity with the WEEE Regulation rh E X hi RoHS Chinese Mainland RoHS TR iis PBA Ri FE 6875 RE PE TB BBD 35 th HA cR SLE ROHS EUR EB 23 SU tH T Barco m rh aT 8E GI d BL ERU SL s JR B n ER Ss PHAMR
19. been made to achieve technical accuracy in this document we assume no responsibility for errors that may be found Our goal is to provide you with the most accurate and usable documentation possible if you discover errors please let us know Barco software products are the property of Barco They are distributed under copyright by Barco N V or Barco Inc for use only under the specific terms of a software license agreement between Barco N V or Barco Inc and the licensee No other use duplication or disclosure of a Barco software product in any form is authorized The specifications of Barco products are subject to change without notice Trademarks All trademarks and registered trademarks are property of their respective owners Copyright notice This document is copyrighted All rights are reserved Neither this document nor any part of it may be reproduced or copied in any form or by any means graphical electronic or mechanical including photocopying taping or information storage and retrieval systems without written permission of Barco 2014 Barco N V All rights reserved 7 7 Technical specifications Overview Foe screen size guns ST Tam TST Active screen size Hx V 432 mm x 324 mm 17 x 12 76 4 3 Aspect ratio H V Resoun PMP 1800 x 1200 Pixel pitch 0 270 Calor imaging Gray imaging Yes Color support 10 bit 7 Values for xx and yy can be found in the technical specifications paragraph
20. ction against harmful interference in a residential installation This device generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this device does cause harmful interference to radio or television reception which can be determined by turning the device off and on the user is encouraged to try to correct the interference by one or more of the following measures e Reorient or relocate the receiving antenna Increase the separation between the device and receiver Connect the device into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help Changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment Canadian notice This ISM device complies with Canadian ICES 001 Cet appareil ISM est conforme la norme NMB 001 du Canada 7 4 EMC notice General information No specific requirement on the use of external cables or other accessories except power supply With the installation of the device use only the delivered power supply or a spare part provided by the legal manufacturer Using another can result in a decrease of the immunity level of
21. d operation To select the white point 1 Bring up the OSD main menu 2 Navigate to the Adjustments menu 3 Enter the White Point submenu 4 Select one of the available white point presets 5 6 OSD menu language About the OSD menu language By default the OSD menu comes up in English However there s a wide range of other languages avail able for the OSD menu of your Eonis display English French German Spanish Italian Dutch Japanese Traditional Chinese Simplified Chinese Korean To select the language of the OSD menu 1 Bring up the OSD main menu 2 Navigate to the Adjustments gt Settings menu 3 Enter the Language submenu 4 Select one of the available languages 5 7 Orientation About orientation The orientation of the OSD menu can be adjusted to landscape or portrait To change the OSD orientation 1 Bring up the OSD main menu 2 Navigate to the Adjustments gt Settings menu 3 Enter the Orientation submenu 4 Select Portrait or Landscape as desired and confirm K5903500 EONIS 17 06 2014 __ 15 5 Advanced operation 5 8 DPMS mode About DPMS mode Enabling the Display Power Management System DPMS mode on your Eonis display will optimize the displays lifetime by automatically switching off the backlight when no video signal is detected for approx imately 10 seconds The power status LED will then turn orange To enable disable DPMS mode
22. e operating instructions Indicates this device must not be thrown in the trash but must be recycled according to the European WEEE Waste Electrical and Electronic Equipment directive IB f Indicates Direct Current DC Indicates Alternating Current AC Stand by Equipotentiality E Symbols on the box On the box of the device you may find the following symbols nonrestrictive list Indicates a device that can be broken or damaged if not handled carefully when being stored Indicates a device that needs to be protected from moisture when being stored Indicates the storage direction of the box The box must be transported handled and stored in such a way that the arrows always point upwards rg Indicates the maximum number of identical boxes which may be stacked on each other where n is the limiting number Indicates that the box should be carried with two persons Indicates that the box should not be cut with a knife a cutter or any other sharp object RIESE EX Fu Indicates the temperature limits to which the device can be safely exposed when being stored T K5903500 EONIS 17 06 2014 7 Important information Indicates the range of humidity to which the device can be safely exposed when being stored Indicates the range of atmospheric pressure to which the device can be safely exposed when being stored 7 6 Legal disclaimer Disclaimer notice Although every attempt has
23. e or more of the following mea sures e Reorient or relocate the receiving antenna or equipment e Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced technician for help Electromagnetic immunity The Eonis is intended for use in the electromagnetic environment specified below The customer or the user of the Eonis should assure that it is used in such an environment Immunity test IEC 60601 Compliance level Electromagnetic environment guidance Electrostatic discharge 6kV contact 6kV contact Floors should be wood ESD BkV air 8kV air concrete or ceramic tile m E If floors are covered with IEC 61000 4 2 synthetic material the relative humidity should be at least 3096 Test levels Electrical fast 2kV for power supply 2kV for power supply Mains power quality transient burst lines lines should be that of a typical commercial or hospital IEC 61000 4 4 1kV for input output 1kV for input output environment lines lines Surge 1 kV line s toline s 1 kV line s to line s Mains power quality IEC61000 4 5 2kVline s to earth 2 kV line s to earth _ SMould be that of a typical commercial or hospital environment K5903500 EONIS 17 06 2014 Immunity test Voltage dips short interruptions and voltage variations on power supply inpu
24. ed and confirm 5 3 Gamma selection About gamma selection Native uncorrected panels will display all grayscale color levels with equal luminance increments Studies have shown however that in medical images certain grayscale color parts contain more relevant informa tion than others To respond to these conclusions gamma functions have been defined These functions emphasize on these parts containing crucial information by correcting the native panel behavior The available gamma functions for your display are K5903500 EONIS 17 06 2014 LLL 13 5 Advanced operation Native If you select Native the native panel behavior will not be corrected e sRGB This is the display function as defined in the sRGB specification and is designed to match typical home and office viewing conditions It is widely used in most computer applications e DICOM DICOM Digital Imaging and Communications in Medicine is an international standard that was developed to improve the quality and communication of digital images in radiology In short the DICOM gamma function results in more visible grayscales in the images Barco recommends selecting the DICOM gamma function for most medical viewing applications Gamma 2 2 Select this function in case the display is to replace a CRT display with a gamma of 2 2 e QAWeb This gamma function will be automatically selected when gamma functions are defined by MediCal QAWeb To select a gamma function 1
25. esthetic mixture Equipment not suitable for use in the presence of a flammable anesthetic mixture with air or with oxygen or nitrous oxide Non patient care equipment e Equipment primarily for use in a health care facility that is intended for use where contact with a patient is unlikely no applied part The equipment may not be used with life support equipment The user should not touch the equipment nor its signal input ports SIP signal output ports SOP and the patient at the same time Power connection Equipment with external 24 VDC power supply e Power requirements The equipment must be powered using the delivered medical approved 24 VDC SELV power supply The medical approved DC power supply must be powered by the AC mains voltage The power supply is specified as a part of the ME equipment or combination is specified as a ME system To avoid the risk of electric shock this equipment must only be connected to a supply mains with protective earth The equipment should be installed near an easily accessible outlet The equipment is intended for continuous operation Transient over voltage If the device is not used for a long time disconnect it from the AC inlet to avoid damage by transient over voltage K5903500 EONIS 17 06 2014 LLL M 7 Important information 22 To fully disengage the power to the device please disconnect the power cord from the AC inlet Power cords Do not o
26. m CD containing MediCal QAWeb Agent set of AC power cord s depending on the region of operation a DVI cable a DP cable a USB cable an external power supply an accessory bag cleaning cloth velcro cable routing strap x Keep your original packaging It is designed for this display and is the ideal protection during transport and storage 4A K5903500 EONIS 17 06 2014 2 Parts controls and connectors 2 PARTS CONTROLS AND CONNECTORS 2 1 Front view Overview Image 2 1 Front sensor USB downstream connector Left Decrease key Right Increase key Menu Enter key Standby key Power status LED NOOR WD K5903500 EONIS 17 06 2014 5 2 Parts controls and connectors 2 2 Rear view Overview Image 2 2 ONOARW N SZ Connector compartment cover Kensington security slots Opening for cable routing strap DisplayPort input DVI input USB downstream connector USB upstream connector USB downstream connector 24 VDC power input K5903500 EONIS 17 06 2014 3 Display installation 3 DISPLAY INSTALLATION 3 1 Adjusting the display position To adjust the display position You can safely tilt swivel raise and lower your display as desired gr Image 3 1 mode make sure you change the orientation of the video input via the screen settings The standard orientation
27. ne MediCal QAWeb service for quality assurance and remote asset management Proving its superior value in hospitals around the world MediCal QAWeb provides automated quality assurance checks and detailed reports It makes it easy for healthcare IT to centrally and remotely manage and configure displays across the healthcare organization Also for private practices QAWeb further strengthens image consistency and allows you to easily personalize your image Features Front sensor automatically aligns image quality IPS panel ensures wide viewing angle MediCal QAWeb suite for networked quality assurance calibration and asset management all add to the exceptional consistent image quality of the Eonis display e Medical grade certifications e Sockets for Kensington lock makes the Eonis display safe for use in clinical environments Flexible VESA mount for easy arm wall or cart mounting Multiple inputs DisplayPort DVI etc ensure the display s flexible deployment This manual further guides you through the different steps needed to install and use the Eonis display CAUTION Read all the important safety information before installing and operating your Eonis display Please refer to the dedicated chapter in this user guide 1 2 What s in the box Overview Your Eonis comes with K5903500 EONIS 17 06 2014 _ 8 7 Welcome this Eonis user guide e a documentation CD containing multilingual user documentation e asyste
28. ng the Display Power Management System DPMS of your display will optimize its lifetime by auto matically switching off the backlight when the display is not used for a specified period of time By default DPMS is enabled on your display but it also needs to be activated on your workstation To do this go to Power Options Properties in the Control Panel Barco recommends setting DPMS activation after 20 minutes of non usage ce Use a screen saver to avoid image retention Prolonged operation of an LCD with the same content on the same screen area may result in a form of image retention You can avoid or significantly reduce the occurrence of this phenomenon by using a screen saver You can activate a screen saver in the Display properties window of your workstation Barco recommends setting screen saver activation after 5 minutes of non usage A good screen saver displays moving content In case you are working with the same image or an application with static image elements for several hours continuously so that the screen saver is not activated change the image content regularly to avoid image retention of the static elements Understand pixel technology LCD displays use technology based on pixels As a normal tolerance in the manufacturing of the LCD a limited number of these pixels may remain either dark or permanently lit without affecting the performance of the product To ensure optimal product quality Barco
29. o make it less than or equal to the native resolution 1600 x 1200 A 2 Warning signals General Sometimes you may see warning messages for this display This means that the display cannot correctly receive the signal form the computer graphics card Problem No signal This message means that the display has been powered on but it cannot receive any signal from the computer graphics card Check all the power switches power cables and video cable Problem Out of range This message means that the signal of the computer graphics card is not compatible with the display When the signal is not included in the compatibility mode we have listed in the appendices of this manual the display will show this message K5903500 EONIS 17 06 2014 _ 35
30. quation applicable to the frequency of the transmitter Recommended separation distance d 1 2 P d 1 2 P 80 MHz to 800 MHz d 2 3 VP 800 MHz to 2 5 Ghz Where P is the maximum output power rating of the transmitter in watts W according to the transmitter manufacturer and d is the recommended separation distance in meters m Field strengths from fixed RF transmitters as determined by an electromagnetic site survey should be less than the compliance 27 7 Important information Immunity test IEC 60601 Compliance level Electromagnetic environment guidance level in each frequency range 4 Test levels Interference may occur in the vicinity of equipment marked with symbol 2 At 80 MHz and 800 MHz the higher frequency range applies 3 These guidelines may not apply in all situations Electromagnetic propagation is af fected by absorption and reflection from structures objects and people Recommended separation distance The Eonis is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled The customer of the user of the Eonis can help prevent electromagnetic interference by main taining a minimum distance between portable and mobile RF communications equipment transmitters and the Eonis as recommended below according to the maximum output power of the communications equipment Rated maximum output Separation distance according
31. rson who connects external equipment to signal input signal output or other connectors has formed a system and is therefore responsible for the system to comply with the requirements of IEC 60601 1 If in doubt speak with a qualified technician In locations where 240 V outlets are used connect this display only on a center tapped 240 V single phase supply Water and moisture Never expose the device to rain or moisture Never use the device near water e g near a bathtub washbasin swimming pool kitchen sink laundry tub or in a wet basement IP x level for MDRC 2221 Ventilation Do not cover or block any ventilation openings in the cover of the set When installing the device in a cupboard or another closed location heed the necessary space between the set and the sides of the cupboard Installation Place the device on a flat solid and stable surface that can support the weight of at least 3 devices If you use an unstable cart or stand the device may fall causing serious injury to a child or adult and serious damage to the device This apparatus conforms to CE MDD 93 42 EEC class product CE 2004 108 EC IEC 60601 1 2005 ANSI AAMI ES60601 1 2005 R 2012 C1 2009 R 2012 A2 2010 R 2012 CAN CSA C22 2 No 60601 1 2008 DEMKO EN 60601 1 2006 EN 60601 1 2 2007 KC VCCI FCC class B ICES 001 Level B FDA Class device RoHS National Scandinavian Deviations for CL 1 7 2 Finland Laite on liitettav
32. t lines IEC 61000 4 11 Power frequency 50 60 Hz magnetic field IEC 61000 4 8 Conducted RF IEC 61000 4 6 Radiated RF IEC 61000 4 3 IEC 60601 Test levels lt 5 U4 1 gt 95 dip in Ux for 0 5 cycle 40 Ux 60 dip in U7 for 5 cycles 70 U7 30 dip in Ur for 25 cycles lt 5 Ur gt 95 dip in U1 for 5s 3 Vrms 150 kHz to 80 MHz 3 V m 80 MHz to 2 5 GHz 1 is the a c mains voltage prior to application of the test level 2 Eonis doesn t contain susceptible components to magnetic fields K5903500 EONIS 17 06 2014 7 Important information Compliance level lt 5 Ur gt 95 dip in U1 for 0 5 cycle 40 Ur 60 dip in Ut for 5 cycles 70 U 30 dip in Ur for 25 cycles lt 5 Ur gt 95 dip in U1 for 5s Not applicable 3V 3 V m Electromagnetic environment guidance Mains power quality should by that of a typical commercial or hospital environment If the user of the Eonis requires continued operation during power mains interruptions it is recommended that the Eonis be powered from an uninterruptible power supply or a battery Power frequency magnetic fields should be at levels characteristic of a typical location in a typical commercial or hospital environment Portable and mobile RF communications equipment should be used no closer to any part of the Eonis including cables than the recommended separation distance calculated from the e
33. to frequency of transmitter power of transmitter I50kHz to 80MHz 80MHz to 800MHz 800MHz to 2 5GHz d 1 2 P d 2 3 P 0 12 0 23 0 38 0 73 1 2 2 3 3 8 7 3 12 23 At 80 MHz and 800 MHz the separation distance for the higher frequency range applies 5 These guidelines may not apply in all situations Electromagnetic propagation is af fected by absorption and reflection form structures object and people 3 Field strengths from fixed transmitters such as base stations for radio cellular cordless telephones and land mobile radios amateur radio AM and FM radio broadcast and TV broadcast cannot be predicted theoretically with accuracy To assess the electromagnetic environment due to fixed RF transmitters an electromagnetic site survey should be considered If the measured field strength in the location in which the Eonis is used exceeds the applicable RF compliance level above the Eonis should be observed to verify normal operation If abnormal performance is observed additional measures may be necessary such as re orienting or relocating the Eonis 4 Over the frequency range 150 kHz to 80 MHz field strengths should be less than 3 V m 5 For transmitters rated at a maximum output power not listed above the recommended separation distance d in meters m can be estimated using the equation applicable to the frequency of the transmitter Where P is the maximum output power rating of the transmitter in watts W according to the
34. verload wall outlets and extension cords as this may result in fire or electric shock Mains lead protection U S Power cord Power cords should be routed so that they are not likely to be walked upon or pinched by items placed upon or against them paying particular attention to cords at plugs and receptacles The power supply cord should be replaced by the designated operator only at all time Usea power cord that matches the voltage of the power outlet which has been approved and complies with the safety standard of your particular country Grounding reliability Grounding reliability can only be achieved when the equipment is connected to an equivalent receptacle marked Hospital Only or Hospital Grade External equipment External equipment intended for connection to signal input output or other connectors shall comply with relevant UL EN IEC standard e g UL EN IEC 60950 for IT equipment and ANSI AAMI ES EN 60601 1 IEC 60601 series for medical electrical equipment In addition all such combinations systems shall comply with the standard IEC 60601 1 safety requirements for medical electrical systems Equipment not complying with ANSI AAMI ES EN IEC 60601 1 shall be kept outside the patient environment as defined in the standard Equipment not complying with IEC 60601 must be kept outside the patient environment as defined in the standard as at least 1 5 meters from the patient or the patient support Any pe