1. Additional Resources These documents contain additional information concerning related products from Rockwell Automation Resource Description IntelliCENTER Software User Manual publication Provides information on using IntelliCENTER software MCC UM001 Industrial Automation Wiring and Grounding Guidelines Provides general guidelines for installing a Rockwell publication 1770 4 1 Automation industrial system Product Certifications website http www ab com Provides declarations of conformity certificates and other certification details You can view or download publications at http www rockwellautomation com literature To order paper copies of technical documentation contact your local Allen Bradley distributor or Rockwell Automation sales representative Rockwell Automation Publication MCC RNOO1D EN P March 2014 Allen Bradley Rockwell Software Rockwell Automation CENTERLINE IntelliCENTER SMC IntelliVAC PowerFlex CompactBlock PowerMonitor DriveExecutive POINT I O FactoryTalk EnergyMetrix RSLogix ControlLogix SoftLogix Entek E1 Plus E3 E3 Plus E300 Logix5000 and XM are trademarks of Rockwell Automation Inc Trademarks not belonging to Rockwell Automation are property of their respective companies Rockwell Otomasyon Ticaret A S Kar Plaza Ig Merkezi E Blok Kat 6 34752 erenk y stanbul Tel 90 216 5698400 www rockwellautomation com Power Control and Information Solut
2. IntelliCENTER software version 4 00 01 is a major version update release Enhancements This update introduces two key features Integration Assistant and Intelli CENTER Energy Integration Assistant is a tool used for adding devices from an IntelliCENTER Motor Control Center MCC into a Logix5000 program or into a FactoryTalk EnergyMetrix server Intelli CENTER Energy software is powered by FactoryTalk EnergyMetrix software and monitors energy data from Intelligent Motor Control devices in the MCC This release contains all of the functionality that was available in the previous version Additional new features include the following e New product support for the PowerMonitor 5000 unit e IP Address Configuration tool for use with E3 and E1 Plus overload relay modules and POINT I O modules e Windows 8 operating system support Rockwell Automation Publication MCC RN001D EN P March 2014 4 IntelliCENTER Software IntelliCENTER Software Version 3 00 01 Updates July 2011 IntelliCENTER software 3 00 01 is a major version update release Enhancements This update introduces support for EtherNet IP MCCs and devices Intelli CENTER software version 3 00 01 can go online and support MCCs that contain EtherNet IP or DeviceNet networks This release also corrects certain anomalies and includes all of the corrections that were part of previous IntelliCENTER software version 2 0 3 service packs Additional new features inc
3. service pack corrects certain anomalies and includes corrections that were part of the previous service pack e For Intelli CENTER program IC 2 0 3 SP4 16 9 MB EXE e For IntelliCENTER ActiveX Only version IC 2 0 3 SP4 AX only 7 5 MB EXE New Product Support for the Bulletin 193 EC5 E3 Plus Electronic Overload Relay Intelli CENTER software now supports voltage and power monitoring through the Bulletin 193 EC5 E3 Plus Electronic Overload Relay DriveExecutive software integration for PowerFlex 753 and PowerFlex 755 Drives DriveExecutive software launches instead of the Monitor view for these drives This feature also extends to other drives New Product Support for the PowerMonitor 3000 Unit Version 4 Meter IntelliCENTER software can now support more parameters for this updated device Additional new features include the following e When multiple networks are detected they are listed in ascending order e Now verifies if RSIOPC Auto dll is registered on machine e Corrected issues with internationalization of the decimal separator e Corrected issues with Create Data CD function and loss of auxiliary device IO e Corrected issue when right clicking columns in Spreadsheet Document ActiveX Rockwell Automation Publication MCC RN001D EN P March 2014 6 IntelliCENTER Software Enhancements for Software Version 2 0 3 Service Pack 3 March 2008 IntelliCENTER software version 2 0 3 Service Pack 3 is an upd
4. Release Notes IntelliCENTER Software Catalog Numbers 2100 and 2500 B Allen Bradley Topic Page IntelliCENTER Software Version 5 00 01 March 2014 1 IntelliCENTER Software Version 4 01 01 February 2013 2 IntelliCENTER Software Version 4 00 01 Updates November 2012 3 IntelliCENTER Software Version 3 00 01 Updates July 2011 4 IntelliCENTER Software Version 2 0 3 Updates 5 IntelliCENTER Software Version 1 4 7 Updates 7 Additional Resources 9 IntelliCENTER Software Version sIntelli CENTER software version 5 00 01 is a major version update release 5 00 01 March 2014 Enhancements New Monitor view to support drives and soft starters Removes need for DriveExecutive software New product support for the following devices E300 electronic overload relay PowerFlex 525 523 drive Improved the Intelli CENTER Integration Assistant for Logix5000 controllers Improved processing speed Clearly prompts you when various scenarios are encountered that prohibit the tool from running or when there are issues during import Improved IntelliCENTER Energy support Improved user interface when communicating with FactoryTalk EnergyMetrix server Intermediate Connect has better support for EtherNet IP networks where nodes are offline Improved security Added new IntelliCENTER first run screen which requires you to change the default password upo
5. ate for IntelliCENTER software version 2 0 3 only It introduces a new Reset Fault button in the Monitor view which can easily reset faults for supported devices This feature must be enabled by the Administrator via the Preferences It includes new product support for the IntelliVAC Plus and PowerFlex 700S devices The service pack corrects anomalies with certain data types that can be used in PowerFlex 7 series or SMC Flex XM 120 devices Blinking Red Light for Faulted Lineups The status bar at the bottom of Intelli CENTER software now shows a blinking red light for a lineup that is faulted It also includes all of the corrections that were part of the previous Service Pack 2 0 3 e For IntelliCENTER program IC 2 0 3 SP3 10 MB EXE e For IntelliCENTER ActiveX Only version IC 2 0 3 SP3 AX only 7 MB EXE Enhancements for Software Version 2 0 3 Service Pack 2 New Test Position State A new device state named Test Position has been added to Intelli CENTER software This state can be associated with a device s I O to determine when the unit is in testing position This new state has been defined for CENTERLINE 1500 Medium Voltage MCCs but does not exist for CENTERLINE 2100 Low Voltage MCCs Selection of State Colors Expanded In the past IntellK CENTER software limited users to seven colors to associate their states Intelli CENTER software now uses a color wheel Therefore you can select
6. from a much wider variety of colors to associate states Double click Bottom Status Bar To view an Elevation view for a lineup you can now double click the associated status panel for the lineup on the bottom status bar The associated Elevation view is automatically shown Enhancements for Software Version 2 0 3 Service Pack 1 New Product Support for E1 Plus Electronic Overload Relay Intelli CENTER software now supports the E1 Plus Electronic Overload Relay with the DeviceNet network Rockwell Automation Publication MCC RN001D EN P March 2014 IntelliCENTER Software Version 1 4 7 Updates IntelliCENTER Software 7 Enhancements for Software Version 2 0 3 New Elevation View IntellK CENTER software has a new version of the Elevation view The features of this new Elevation view include the following e Drag and drop moving of units and sections e Icons show the type of DeviceNet network product in each unit e Customizable device descriptions and location fields e Add and delete units e Copy and paste units or sections offline only Enhanced Fault Logging Faults and warnings are now logged with the specific code or description for clarification with diagnostics and troubleshooting New Product Support for E3 Electronic Overload Relay in Feeder Applications IntelliCENTER software now supports E3 Electronic Overload Relays used in feeder applications The description and parameters monitored have been tailored to t
7. his application ActiveX Controls Support Third party Human Machine Interfaces HMIs Modifications have been made to the IntelliCENTER ActiveX controls to support third party HMIs The following enhancements are included in Intelli CENTER software version 1 4 7 Enhancements for Software Version 1 4 7 Service Pack 5 January 2006 Service Pack 5 is an update for 1 4 7 software only It corrects an anomaly with writing to parameters in an E1 Plus Electronic Overload Relay It also corrects a rare issue that caused values to be reported incorrectly in the Monitor view It contains all of the corrections that were part of the previous Service Pack 1 4 7 This service pack contains the following files e IC 1 4 7 SP5 13 MB EXE e IC 1 4 7 SP5 Release Notes PDF file Enhancements for Software Version 1 4 7 Service Pack 4 New Product Support for PowerFlex family Intell CENTER software now supports the PowerFlex 700H and PowerFlex 400 drives Rockwell Automation Publication MCC RN001D EN P March 2014 8 IntelliCENTER Software Enhancements for Software Version 1 4 7 Service Pack 1 New Product Support for 825P Intelli CENTER software now supports the 825P Modular Protection Device Enhancements for Software Version 1 4 7 Offline Mode Now use IntelliCENTER software without being connected to a DeviceNet MCC This is useful before the MCC is installed or when you work offsite While you do not see real time data you ca
8. ions Headquarters Americas Rockwell Automation 1201 South Second Street Milwaukee WI 53204 2496 USA Tel 1 414 382 2000 Fax 1 414 382 4444 Europe Middle East Africa Rockwell Automation NV Pegasus Park De Kleetlaan 12a 1831 Diegem Belgium Tel 32 2 663 0600 Fax 32 2 663 0640 Asia Pacific Rockwell Automation Level 14 Core F Cyberport 3 100 Cyberport Road Hong Kong Tel 852 2887 4788 Fax 852 2508 1846 Publication MCC RN001D EN P March 2014 Supersedes Publication MCC RNOO1C EN P February 2013 Copyright 2014 Rockwell Automation Inc All rights reserved Printed in the U S A
9. lude the following New link to email technical support from within Intelli CENTER software A screen capture and computer data are saved as files to include as attachments New product support for the following devices POINT I O 1734 ADN DeviceNet module POINT I O 1734 AENT EtherNet IP module PowerMonitor 1000 unit only web page status support 857 Motor Feeder protection relay CompactBlock LDX 1790D T8A0 module IntelliCENTER Document and Spreadsheet ActiveX controls now feature edit capability Ability to launch device web pages within IntelliCENTER software if supported by device and network Windows Vista 7 operating system support User can edit the names of view User Fields by right clicking the column header New grid control for Documentation views Rockwell Automation Publication MCC RN001D EN P March 2014 IntelliCENTER Software 5 IntelliCENTER Software Version The following enhancements are included in Intelli CENTER software version 0 3 2 0 3 Updates Enhancements for Software Version 2 0 3 Service Pack 4 March 2010 IntelliCENTER software 2 0 3 Service Pack 4 is an update for 2 0 3 software only It introduces new Bulletin 193 EC5 E3 Plus Electronic Overload Relay with voltage and power monitoring It incorporates DriveExecutive software for easy integration with the PowerFlex 753 and PowerFlex 755 AC drives It also provides support for the new PowerMonitor 3000 unit revision 4 The
10. n still do the following e View and edit the drawings manuals spare parts and event log e Move and add units e Edit units for example edit nameplates and I O labels Data CD Creation After making changes to Intelli CENTER software in the field moving units adding units or changing documentation you can now create your own Data CD to back up the new configuration New Product Support Intelli CENTER software now supports the PowerFlex 40 AC drive the SMC Flex controller and the Entek XM 120 vibration module The Entek capability lets you view the mechanical and electrical status of critical motors within IntelliCENTER software Copy Existing Lineups During startup MCC units are often moved within a lineup or between lineups With Intelli CENTER software you can view these moves However when many units are moved the changes required within Intelli CENTER software can be overwhelming In some cases it can be easier to start with an empty MCC Accordingly a new function has been created to allow copying existing MCC lineups with or without MCC units ActiveX Updates The ActiveX object has been updated to version 2 IMPORTANT Applications created with version 1 objects are not compatible with version 2 objects To use the new version 2 objects each version 1 object must be deleted and replaced with the version 2 object Rockwell Automation Publication MCC RN001D EN P March 2014 IntelliCENTER Software 9
11. n the first time of launching IntelliCENTER software if you have not done so already IntelliCENTER Communication service now runs as Local service Commercial documentation updated to better explain security impacts Rockwell Allen Bradley Rockwell Software Automation 2 IntelliCENTER Software IntelliCENTER Software Version 4 01 01 February 2013 Corrected Anomalies e CORRECTED Allow non alphabetical password combinations e CORRECTED Administrator and user account policies were improved e CORRECTED Multiple issues with event logging were addressed e CORRECTED Fixed anomalies with applying user s access level e CORRECTED Fixed anomaly with network path after copying a lineup e CORRECTED Fixed anomaly when customer inserts their own user manuals drawings e CORRECTED Fixed an issue that prevents IntelliCENTER software from working on a non English operating system Known Anomalies IntelliCENTER software version 5 00 01 and later does not communicate with PowerFlex 753 755 drives via the 20 COMM D option card The 20 COMM D option card is not a supported option for the PowerFlex 753 755 drives Use the 20 750 DNET option card to communicate with the PowerFlex 753 755 drives over the DeviceNet network IntelliCENTER software version 4 01 01 is a minor version update release It includes some new features and corrected anomalies from IntelliCENTER software version 4 00 01 Enhancements e Integrati
12. on Assistant for Logix5000 controllers now supports CompactLogix and SoftLogix projects in addition to ControlLogix projects e Integration Assistant for Logix5000 controllers now handles instances where the current language for the computer does not match an installed language pack for RSLogix 5000 software e Integration Assistant for FactoryTalk EnergyMetrix software now supports operating systems where the decimal separator is not e IntelliCENTER databases are compressed when closing the application to keep the databases from getting too large Rockwell Automation Publication MCC RN001D EN P March 2014 IntelliCENTER Software Version 4 00 01 Updates November 2012 IntelliCENTER Software 3 Corrected Anomalies e CORRECTED Use the status of auxiliary devices when indicating the status for the unit e CORRECTED Correctly associates POINT I O child modules for motor control centers that contain more than one POINT I O adapter module e CORRECTED Supports DriveExecutive software version 5 01 99 without requiring a later version e CORRECTED Login and logout capability in Documentation Spreadsheet ActiveX controls so that the view is editable e CORRECTED Creation of new user accounts works correctly now e CORRECTED Login and logout works with all Latin character password combinations e CORRECTED After adding a new I O point you no longer need to close and reopen IntelliCENTER software
Download Pdf Manuals
Related Search
Related Contents
Prime-Line N 6517 Instructions / Assembly OMEPRAZOLE EG® 40 mg Samsung GT-E1182 Felhasználói kézikönyv Nivobob® Nilfisk-ALTO PS Series User's Manual DS-MPE-GPIO Hardware User Manual Dell PowerEdge M520 Statement of Volatility Copyright © All rights reserved.
Failed to retrieve file