On-Q/Legrand inQuire Intercom System

image

Contents

1. A total of TWO Cat 5e runs are required to operate the Main Console Unit Run TWO Cat 5e cable runs from the 3 gang box directly to the enclosure where the Intercom Module will be installed You must label both ends of the cable runs for the Main Console Unit to ensure proper termination during the trim out Label one cable Main 1 and the other cable Main 2 Follow the wiring guidelines listed in this manual to ensure a quality cable installation 2 Room Unit s The procedure to rough in the Room Unit s is as follows Typically the Room Unit s will be installed on the same wall as the door to the room Verify each Room Unit location with the homeowner before proceeding Avoid installing Room Units in the same stud cavity on opposite sides of the wall to prevent feedback problems The Room Unit mounts in a standard 2 gang electrical box The use of an enclosed box rather than an open mud ring will help minimize the potential for feedback between units Any UL approved metal or plastic gang box can be used To avoid damage from debris during construction or after construction use a gang box that will completely enclose the unit The 2 gang box should be installed at the same height as the electrical switch boxes in the home ONE Cat 5e run is required to operate the Room Unit Run ONE Cat 5e cable from the 2 gang box directly to the enclosure where the Intercom Module will be installed Label both ends of your cable run to ind
2. conditions these instructions must be followed to ensure a quality installation Brick or other cement based material exteriors e The recommended box to use is a 2 gang outdoor weatherproof box This box should be of the type that is made of heavy die cast aluminum Using a heavy die cast aluminum box will provide adequate strength in a brick or cement based exterior 301 Fulling Mill Road Suite G Copyright 2006 by On Q Legrand Inc Page 9 Middletown PA 17057 All Rights Reserved 800 321 2343 www onglegrand com Vinyl or wood based siding material exteriors e f possible use a heavy duty die cast aluminum 2 gang box if it can be securely mounted to the interior framing If this is not possible then it is recommended that you use a heavy duty metal 2 gang box that can be securely mounted to the interior framing of the home To ensure the 2 gang box that will be used to house the Door Unit is roughed in correctly communication with the building contractor who Is responsible for the exterior finish of the home is highly recommended Brick or other cement based material exteriors e The masonry contractor must be provided with specific instructions as to how the 2 gang box should be installed including location correct positioning and proper depth e f possible clearly mark this information on the home s exterior insulation board or vapor barrier material to serve as a reminder to the mason e _ The correct positioning
3. 06 by On Q Legrand Inc Page 10 301 Fulling Mill Road Suite G Copyright 2006 by On Q Legrand Inc Page 15 Middletown PA 17057 All Rights Reserved Middletown PA 17057 All Rights Reserved 800 321 2343 www onglegrand com 800 321 2343 www onglegrand com Ci legrand Ci legrand 3 on o Ci legrand e Insert the Room Unit and the Cat 5e cable into the 2 gang box and secure the unit to the box using the 4 included screws Attach a 2 gang decor plate to the unit to complete the installation e Repeat these instructions for all the Room Units in your inQuire 1000 Intercom System Desktop Unit s The procedure to trim out the Desktop Unit s is as follows e Locate a Cat 5e cable in a roughed in 1 gang box labeled as Desktop Unit X X is the Desktop Unit number e Strip approximately 2 of insulation from the Cat 5e cable e Untwist cable pairs but be sure to leave 1 2 twist in the pairs between the punchdown insert and the start of the cable insulation Desktop Unit Figure 7 TrimrOuk Desktop Unit s see Figure 7 e Following T568A wiring color code place the pairs firmly into their appropriate positions on the punchdown insert Ensure that the individual conductors are seated tightly enough to allow you to punch them down without having to hold them in place e Using a punchdown tool with a 110 style cutting blade punch down each conductor firmly enough to allow any excess conductor to be c
4. J45 crimp tool e Plug the terminated Room Unit X cable into the RJ45 jack on the rear of the Room Unit see Figure 6 Te YW YN dd aT hr H jae V ech bech Leg EM de Wi i lel o Fe f SC Be dE a E Bs Yn y Y Figure 6 Plug Room Cable into Room Unit 301 Fulling Mill Road Suite G Copyright 2006 by On Q Legrand Inc Page 13 Middletown PA 17057 All Rights Reserved 800 321 2343 www onglegrand com
5. SE There is no specific button on the Room Unit for the DOOR RELEASE function However by depressing both the TALK and the DOOR buttons at the sane tine the Unit will engage the door release device not included with the Intercom Systen if a door release device is installed in conjunction with the Intercom System Once you let go of the TALK and DOOR buttons the door release device will be disengaged which will lock the door again 301 Fulling Mill Road Suite G Copyright 2006 by On Q Legrand Inc Middletown PA 17057 800 321 2343 All Rights Reserved www onglegrand com ANSWER LED This LED is located at the top of the keypad of the RoomUnit When lit the LED indicates that the microphone in the unit is active and anything you say will be comunicated through the system This LED will light when you are depressing the TALK or DOOR buttons The LED will be constantly lit when the unit is in MONITOR node DOOR Depressing this button will allow you to contrunicate with all Door Units that are part of your system Hold in the DOOR button while speaking and let it go when you are done Your voice will be heard on any active Room Patio or Desktop Units and all Door Units within the system MONITOR Press this button once to put the Unitin MONITOR mode Press the button again to reum the Unit back to nonmal node While in MONITOR noce the nicrophone is constantly active the speaker is disabled and any voice or noise within the
6. Units and all Door Units within the system MONITOR Press this button once to put the Unit in MONITOR rode Press the button again to reum the Unit back to normal mode While in MONITOR noce the nicrophone is constantly active the speaker is disabled and any voice or noise within the roomwlll be heard throughout the system The LED to the right of the MONITOR button will glow green when in MONITOR mode Multiple Units can be in MONITOR noce at the sane tine This function is useful for baby monitoring or other types of situations which require any voice or noise in a roomto be heard throughout the system NOTE When in MONITOR mock a door bdl button push ata Door Unit will not result in a door chine rina at the Room Unit VOLUME There are two volume control buttons with an associated volurre level LED bar There are 20 different volurre levels which are adjusted up and down using these two buttons Pressing the volune up button once will increase the volurre one level higher You may not see the LEDs change until you press the volurre up or down multiple tines approximately every sixth button press You can also hold in the volurre up or down button until you have reached the desired volurre level It is recontrended that you keep the volurre level in the middle position 3 LEDs lit for opinumsound quality KEYPAD BRIGHTNESS If the default Dimlevel of the backlit buttons is not adequate for the user then press both Volunre
7. an be found in this manual NOTE The proper termination of the RJ45 plugs is critical the correct operation of the inQuire 1000 Intercom System Incorrect termination could result in damage or improper operation of the system e f you are using a door release device then you must terminate the two conductors from your door release device to the Intercom Module by routing the conductors through the mounting bracket before inserting the Intercom Module into its mounting bracket The door release device conductors are to be terminated to the blue mounting block JP202 located on the rear circuit board of the Intercom Module Maintain correct polarity see Figure 11 301 Fulling Mill Road Suite G Copyright 2006 by On Q Legrand Inc Page 17 Middletown PA 17057 All Rights Reserved 800 321 2343 www onglegrand com on o e Untwist cable pairs but be sure to leave 1 2 twist in the pairs between the punchdown block and the start of the cable insulation see Figure 9 2 max untwisting gasket Figure 9 TrimrOuck Door Unit s e As shown in the diagram the Cat 5e cable must be terminated so that the cable is routed to the punchdown block so that the unit can be installed into a standard gang box while maintaining proper bend radius e Following T568A wiring color code place the pairs firmly into their appropriate positions on the punchdown block Ensure that the individual conductors are seated tightly enough to allow
8. ananaundinedauntncesamensacnnsanens 2 A System Components E 2 Ill Wiring Ee d E 4 ele EEN 4 SE TEE 4 C Unit Placement US as dd AC AR dd FOD OND 4 D Termination ere Did e EE 4 IV System dite ke E E 6 A Pre Wiring COUSIN ANIM EE 6 B Filta A n dao K td Te WEE 12 V system Operational OverviEW ccmcnsacsscnanennncnwuectarstuananennancsdsnadetsaaniaentadnancencmesansaananenandewoes 19 A Main Console Unit E 19 B eeng E 20 C Desktop RE E 21 D ncn UO e E 22 E Door UNI acerca O YO EU YG o Ad goes anise dace ae 23 VII e e UNG DE 24 A Contact are dn le 24 B Jet eeler Eege 24 C Warranty Information eege eeben 25 301 Fulling Mill Road Suite G Copyright 2006 by On Q Legrand Inc Page ii Middletown PA 17057 All Rights Reserved 800 321 2343 www onglegrand com Ci legrand Notes C Warranty Information LIMITED ONE YEAR PRODUCT WARRANTY On Q Legrand On Q warrants to the original end user Customer that those products manufactured by or for On Q Warranted Products as conclusively evidenced by the name or logo of On Q appearing on the product will be free from defects in workmanship and materials under normal use for 1 one year from the date of original purchase from On Q or its authorized dealer or installer The sole obligation of On Q under this express warranty shall be at the option and expense of On Q to replace the product with a comparable product or repair the product In no event shall On Q be lia
9. ave other rights which vary from state to state Some states do not allow limitations on how long an implied warranty lasts so the above limitation may not apply to the Purchaser Some states do not allow the exclusion or limitation of incidental or consequential damages so the above limitation or exclusion may not apply to the Purchaser Obtaining Warranty Service Customer must contact an On Q authorized Dealer or Installer within the applicable warranty period to obtain warranty service Dated proof of original purchase from On Q or its authorized Reseller or Dealer will be required 301 Fulling Mill Road Suite G Copyright 2006 by On Q Legrand Inc Page iii 301 Fulling Mill Road Suite G Copyright 2006 by On Q Legrand Inc Page 25 Middletown PA 17057 All Rights Reserved Middletown PA 17057 All Rights Reserved 800 321 2343 www onglegrand com 800 321 2343 www onglegrand com Ll legrand El legrand VI Troubleshooting This section will detail possible solutions to common problems that might occur during installation of or in using the On Q Legrand inQuire 1000 Intercom System A Contact Information If you are unable to locate a solution here please access our website at www onqlegrand com for the latest information You can also reach us at 1 800 321 2343 B Troubleshooting Guide I Installation Safety Precautions NOTE Read all instructions carefully and completely before installing the On Q Le
10. ble for incidental consequential or punitive damages or for labor or other costs in connection with diagnosing repairing removing installing shipping servicing or handling the defective product Replacement products may be new rebuilt remanufactured or reconditioned On Q warrants any replaced or repaired product for a period of ninety 90 days from shipment or through the end of the original warranty period whichever is longer On Q makes no warranty with respect to products it sells that do not contain the authorized On Q name or logo and Customer by acceptance of the product agrees that its sole and exclusive remedy shall be against the manufacturer of such product The foregoing warranty for Warranted Products does not extend to i damage or repairs required as a result of improper wiring misuse misapplication abuse improper servicing unauthorized alteration improper operation or handling storage installation or operation that is not in accord with instructions that may be furnished with the product ii failures due to abnormalities in or interruption of electrical service or iii damage caused by lightning floods winds fires accidents corrosive atmosphere temperature extremes or other conditions that are beyond the control of On Q Original purchases or replacement products may be new rebuilt remanufactured or reconditioned This warranty gives the Purchaser specific legal rights and the Purchaser may also h
11. buttons at the sane tine and release them Use the Up or Down Volurre button to brighten or dimthe default backlight level When the desired level is reached either push both buttons at the sarre tine again to resurre nomal operation or just let the Unit time out after about 10 seconds to reum to nomal operation NOTE When in use the Unit s backlight level is at full brighiness and retums to the set backlight Dimlevel upon timeout about 10 seconds 301 Fulling Mill Road Suite G Copyright 2006 by On Q Legrand Inc Page 21 Middletown PA 17057 All Rights Reserved 800 321 2343 www onglegrand com Ci legrand B Room Unit Please refer to Figure 13 to familiarize yourself with the operation of the inQuire 1000 Room Unit TALK Depressing this button will allow you to contrunicate with all other active units Hold in the TALK button while speaking and let it go when you are on o Ci legrand done Your voice will be heard on the Main Console Unit as well as any active Room Patio or Desktop Unit within the system MUTE Press this button once to put the Unit in MUTE node Press the button again to retum the Unit back to normal mode While in MUTE mode both the speaker and microphone of the unit will be inactive and the LED to the right of the MUTE button will glow red MUTE node is useful for maintaining privacy in a particular room Multiple rooms can be in MUTE mode at the sane ne DOOR RELEA
12. d radio TV technician for help Reprinted from the Code of Federal Regulations 47 part 15 193 1993 Washington DC Office of the Federal Register National Archives and Records Administration U S Government Printing Office WARNING TO PREVENT FIRE OR SHOCK HAZARD DO NOT EXPOSE THIS PRODUCT TO RAIN OR MOISTURE THE UNIT MUST NOT BE EXPOSED TO DRIPPING OR SPLASHING WATER CAUTION DO NOT OPEN THE UNIT DO NOT PERFORM ANY SERVICING OTHER THAN THAT CONTAINED IN THE INSTALLATION AND TROUBLESHOOTING INSTRUCTIONS REFER ALL SERVICING TO QUALIFIED SERVICE PERSONNEL CAUTION THIS DEVICE MUST BE INSTALLED AND USED IN STRICT ACCORDANCE WITH THE MANUFACTURER S INSTRUCTIONS AS DESCRIBED IN THE USER DOCUMENTATION THAT COMES WITH THE PRODUCT WARNING POSTPONE INSTALLATION UNTIL THERE IS NO RISK OF THUNDERSTORM OR LIGHTNING ACTIVITY IN THE AREA When using this device basic safety precautions should always be followed to reduce the risk of fire electric shock and injury to persons including the following Read all of the instructions listed here and or in the user manual before you operate this equipment Give particular attention to all safety precautions Retain the instructions for future reference Comply with all warning and caution statements in the instructions Observe all warning and caution symbols that are affixed to this equipment Comply with all instructions that accompany this equipment Avoid using this product during a
13. e and anything you say Wil be comtrunicated through the system This LED wil light when you are depressing the TALK or DOOR buttons DOOR Depressing this button will allow you to contrunicate with all Door Units that are part of your system Hold in the DOOR button while speaking and let it go wnen you are done Your woice will be heard on any active Room Patio or Desktop Units and all Door Units within the system TALK HANDS FREE Press and hold this button while talking to put all active Room Units in Hands Free Mode All active not in Mute or Monitor Mode RoomUnit s microphones are activated so that other intercomusers can contrunicate without pressing their TALK buttons The Hands Free Mode stays in effect for 20 30 seconds or until the TALK HANDS FREE button on the Main Console is pressed again VOLUME There are wo volurre control buttons with an associated volurre level LED bar There are 20 differert volurre levels which are adjusted up and down using these two buttons Pressing the volurre up button once will increase the volume one level higher You may not see the LEDs change until you press the volurre up or down multiple tives approximately every sixth button press You can also hold in the volurre up or down button until you have reached the desired volurre level Itis recomtrended that you keep the volurre level in the middle position 3 LEDs lit for optinumsound quality If the default Dimlevel of the backlit bu
14. ed to any Cat 5e outlet with its supplied cable 301 Fulling Mill Road Suite G Copyright 2006 by On Q Legrand Inc Page 2 301 Fulling Mill Road Suite G Copyright 2006 by On Q Legrand Inc Page 23 Middletown PA 17057 All Rights Reserved Middletown PA 17057 All Rights Reserved 800 321 2343 www onglegrand com 800 321 2343 www onglegrand com D legrand D legrand D Patio Unit Please refer to Figure 15 to familiarize yourself with the operation of the inQuire 1000 Patio Unit ANSWER LED This LED is located at the top of the keypad of the Patio Unit Wren lit the LED indicates that the microphone in the unit is active and anything you say will be comrunicated through the system This LED will light when you are depressing the TALK or DOOR buttons The LED will be constantly lit When the unit is in MONITOR mode TALK Depressing this button will allow you to communicate with all other active units Hold in the TALK button while speaking and let it go when you are done Your voice will be heard on the Main Console Unit as well as any active Room Patio or Desktop Unit within the system DOOR Depressing this button will allow you to contrunicate with all Door Units that are part of your system Hold in the DOOR button while speaking and let it go when you are done Your voice will be heard on any active Room Patio or Desktop Units and all Door Units within the system MONITOR Pres
15. em then the Units may not power on Check the Cat 5e cable tenvinations at both the rear of the Unit or at the outlet for Desktop Units and at the IntercomModule Verify that your terrrinations follow the T568A wiring standard If your Wiring tenvinations are visibly correct according to the T568A standard test the conductivity of the connections and re temrinate if a problemis found Check to see if a Unit will power on by plugging it into a different port on the Intercom Module Verify Unit placerrent Avoid placing Units back to back on a common wall If Units must be placed on both sides of a common vall do so in a manner which avoids feddback problems ensuring that the audio froma Unit s speaker will not be audible to a nearby Units rricrphone Feedback issues can normally be elirrinated by adjusting the volurre of a Unit from a high level to a redumlevel Verify that the proper wiring guidelines found in this manual have been followed Verify that Cat 5e cabling does not run parallel to and within 12 inches of AC power cabling Also avoid running Cat 5e cabling near florescent lighting fixtures dinner switches or fan controls Look at the rear circuit board of the Intercom Module Locate the pin array labeled J P100 The Unit is shipped with a shorting block installed on two of the pins These pins are the topnost pins and are located directly undemeath the label J P100 Make sure this shorting block is installed Veri
16. fy that the third Door Unit is plugged into the port on the front of the Intercom Module labeled 12 DOOR 3 By default the 12 DOOR 3 port on the Intercom Module is configured to operate a Room Unit To use this port for a third Door Unit you msst first remove the shorting block which is installed on the top two pins of the pin array labeled J P100 on the rear Circuit board of the IntercomModule Copyright 2006 by On Q Legrand Inc Page 24 All Rights Reserved www onglegrand com must conform to all local building and electrical codes Do not apply power to the Intercom Module until all inQuire 1000 Intercom System components have been installed and all wiring has been properly terminated Do not attempt to terminate change or un install any wiring without first turning off power at the Intercom Module which is located in the On O enclosure Unplug the power transformer that is powering the Intercom Module from the power outlet before proceeding with wiring terminations or changes Install each component of this system away from heat sources such as heating ducts registers stoves or any other heat source Do not install any component in a return air duct The inQuire 1000 Intercom Module and any other component module were designed to be installed into an On Q Legrand enclosure This enclosure must be installed in a cool dry area and must be installed according to its installation instructions Do not install an O
17. g and proper depth e f possible clearly mark this information on the home s exterior insulation board or vapor barrier material to serve as a reminder to the mason e The correct positioning of the 2 gang box may not be obvious to the masonry contractor Ensure that the masonry contractor knows which edge of the box is up and which edge is down so that the Patio Unit can be installed in the correct vertical position 301 Fulling Mill Road Suite G Copyright 2006 by On Q Legrand Inc Page 8 Middletown PA 17057 All Rights Reserved 800 321 2343 www onglegrand com on o Ci legrand e Place the Door Chime circuit board on the rear of the Intercom Module so that the two mounting holes on the Door Chime circuit board are seated on the Intercom Module threaded mounting studs see Figure 10 Fiaqure 10 Install Door Chine e Ensure that the Door Chime s pin array socket is properly aligned with the pin array labeled JP203 on the Intercom Module e _ Apply slight downward pressure to the Door Chime circuit board to securely seat the pin aaray connections together e Use the included hex nuts and washers to secure the Door Chime circuit board to the Intercom Module mounting studs Intercom Module The procedure to install the Intercom Module is as follows e Terminate all cable runs from Room Units Desktop Units Patio Units Door Units and the Main Console Unit using RJ45 plugs Follow the T568A wiring standard which c
18. grand inQuire 1000 Intercom System Throughout the following safety precautions and instructions the term component will be used to indicate one or all of the following Intercom Module Main Console Unit Room Unit Desktop Unit Patio Unit or Door Unit e These installation instructions were designed for use by an authorized On Q installer only Do not attempt to service move or change any component of this system unless you are qualified to do so e This system must by installed by an authorized On Q Legrand Installer and No power to a specific RoomUnit Desktop Unit Patio Unit Door Unit or Main Console Unit Feedback or squeal noise fromMain Corsole Unit Room Unit Desktop Unit Patio Unit or Door Unit speaker Humor buzzing noise that can be heard in sorre or all units of the inQuire 1000 Intercom System A Room Unit that is Plugged into the port labeled 12 DOOR 3 on the Intercom Module is not functioning correctly A third Door Unit is not functioning properly 301 Fulling Mill Road Suite G Middletown PA 17057 on O 800 321 2343 Ci legrand Check Intercom Module power LED to verify that it is lit If not nake sure power supply is Plugged in Verify that you are using the correct LA power supply for your system by obtaining the mode number and calling your On Q installer or On O Technical Support If you are not using a 12V power supply that supplies enough current to the syst
19. his component installs as an add on to the Intercom Module It enables a chime to be heard on all the units that are not in MUTE or MONITOR mode throughout the inQuire 1000 Intercom System 301 Fulling Mill Road Suite G Copyright 2006 by On Q Legrand Inc Page 3 Middletown PA 17057 All Rights Reserved 800 321 2343 www onglegrand com lll Wiring Specifications C Desktop Unit A Specifications Please refer to Figure 14 to familiarize yourself with the operation of the inQuire 1000 Desktop Unit e Minimum cable rating Category 5 UTP 4 pair solid conductors 24 AWG 100 ohm 100 Mhz General Purpose CM UL listed Maximum length per run 325 feet Termination standard T568A Terminating plug type where necessary Solid Conductor RJ45 Terminating block type where available 110 style IDC B Guidelines Do not exceed 25 lbs of force when pulling cable Do not splice cables Do not staple cables Use wire ties with screw mounts to loosely secure cabling Avoid running Cat 5 cable parallel to 120V 240V AC wiring or fixtures within 12 inches Avoid ganging any intercom unit with a lighting dimmer switch Maintain at least 12 inches of separation from dimmer switches If you must cross AC wiring do so at a 90 degree angle with at least 2 inches of separation Maintain a minimum 1 bend radius Do not untwist Cat 5 conductors more than 1 2 at any termination point Keep cables away from HVAC ducts or any
20. hone of the unit will be inactive and the LED to the right of the MUTE button will glow red MUTE node is useful for maintaining privacy on the patio Multiple units can be in MUTE mode at the sane tine PATIO UNIT DISABLE If security mode wes enabled by removing the shunt on J 3 on the rear of the Intercom Module the Patio Unit can be disabled tenporarily by simultaneously pressing and releasing the TALK and DOOR RELEASE buttons on the Main Console Unit The Patio Unit Status LED should blink slowy Red and then Green To re enable the Patio Unit again sirrultaneously press ard release the TALK and DOOR RELEASE buttons on the Main Console Unit NOTE There is no Door Release function enabled on the Patio Unit 301 Fulling Mill Road Suite G Copyright 2006 by On Q Legrand Inc Page 22 D Middletown PA 17057 All Rights Reserved 800 321 2343 www onglegrand com Ci legrand on o Oi legrand Patio Unit This unit also provides typical Room Unit functionality in a weather resistant wall mounted package for your patio For security reasons its door release functionality may be disabled Door Unit This unit allows a visitor to the home to press the door chime button on the unit to notify the occupants of their presence reguires Door Chime to be installed The occupants can then initiate a two way communication with the visitor and even open the door reguires electronic door relese device not included Door Chime T
21. icate Room Unit number ex Room Unit 5 Follow the wiring guidelines listed in this manual to ensure a quality cable installation Repeat these instructions for each and every Room Unit that will be installed in the system maximum of 12 3 Desktop Unit s The procedure to rough in the Desktop Unit s is as follows on o Ci legrand Typically the Desktop Unit s will be connected to a Cat5e outlet on a wall where the desk or nightstand will be placed Verify each Desktop Unit location with the homeowner before proceeding The Cat 5e outlet for the Desktop Unit typically mounts in a standard 1 gang electrical box or mud ring Any UL approved metal or plastic gang box can be used The 1 gang box should be installed at the same height as the electrical outlet boxes in the home 301 Fulling Mill Road Suite G Copyright 2006 by On Q Legrand Inc Page 7 Middletown PA 17057 All Rights Reserved 800 321 2343 www onglegrand com 4 on o Ci legrand e ONE Cat 5e run is required to operate the Desktop Unit e Run ONE Cat 5e cable from the 1 gang box directly to the enclosure where the Intercom Module will be installed Label both ends of your cable run to indicate Desktop Unit number ex Desktop Unit 5 Follow the wiring guidelines listed in this manual to ensure a quality cable installation e Repeat these instructions for each and every Desktop Unit that will be installed in the system maximum of 12 Patio Uni
22. ice not included with the IntercomSysten if a door release device is installed Once you let go of the button the door release device will be disengaged which will lock the door again PATIO UNIT DISABLE If a Patio Unit is installed in Port 41 and security mode wes enabled by removing the shunt onJ 3 on the rear of the IntercomModule the Patio Unit can be disabled terrporarily by simultaneously pressing and releasing the TALK and DOOR RELEASE buttons on the Main Console Unit The Patio Unit Status LED should blink slowy Red and then Green To re enable the Patio Unit again simultaneously press ard release the TALK and DOOR RELEASE buttons on the Main Console Init STATUS LEDs Each LED indicates the status of each RoomuUnit in the system A GREEN light indicates that the Room Unit s Talk or Door button is depressed and sorreone is talking with the unit A RED light indicates that the Room Unit is in MUTE mode and that all speaker and microphone functions of the unit are disabled An ORANGE light indicates that the unit is in Monitor node and its microphone is currently active Pre printed and blank labels are induded in the package to identify LEDs 301 Fulling Mill Road Suite G Copyright 2006 by On Q Legrand Inc Middletown PA 17057 All Rights Reserved 800 321 2343 www onglegrand com Ci legrand ANSWER LED This LED is located at the top of the keypad When lit the LED indicates that the microphone in the unit is activ
23. in the opening for the various inQuire 1000 Intercom System components see Figure 3 Main Console Unit Room Units Patio Unit Desktop Door Unit Unit Figure 3 inQuire 1000 IntercomSystem Rougi in Phase 1 Main Console Unit The procedure to rough in the Main Console Unit is as follows e Since the Main Console Unit provides status LEDs for monitoring of the entire intercom system it is recommended that this unit is installed in a central location Traditionally this unit is installed in the kitchen area Verify the location with the homeowner before proceeding e The Main Console Unit mounts in a standard 3 gang electrical box The use of an enclosed box rather than an open mud ring will help minimize the potential for feedback between units e Any UL approved metal or plastic gang box can be used 301 Fulling Mill Road Suite G Copyright 2006 by On Q Legrand Inc Page 6 D Middletown PA 17057 All Rights Reserved 800 321 2343 www onglegrand com Ci legrand Please refer to Figure 12 to familiarize yourself with the operation of the inQuire 1000 Main Console Unit TALK Depressing this button will allow you to contrunicate with all other active units Hold in the TALK button while speaking and let it go when you are done Your voice will be heard on any active Room Patio or Desktop Unit within the system DOOR RELEASE Pressing the DOOR RELEASE button will engage the door release dev
24. ire 1000 ImercomSystemTrimOut Phase Repeat the previous steps for the cable labeled Main 2 Insert the Main Console Unit and the Cat 5e cables into the 3 gang box and secure the unit to the box using the 6 included screws Attach a 3 gang decor plate to the unit to complete the installation Terminate the other end of each labeled Cat 5e cable in the enclosure and plug the Main 1 cable into the jack on the Intercom Module labeled MAIN 1 and plug the Main 2 cable into the jack on the Intercom Module labeled MAIN 2 Once all Units have been trimmed out use the provided location labeling sheet R1596 to label each location in the status section on the front of the Main Console see Figure 5 This really helps make your system installation much more professional 301 Fulling Mill Road Suite G Copyright 2006 by On Q Legrand Inc Page 12 Middletown PA 17057 All Rights Reserved 800 321 2343 www onglegrand com on o Ci legrand Figure 5 Label Each Location on Main Console Room Unit s The procedure to trim out the Room Unit s is as follows e Locate a Cat 5e cable in a roughed in 2 gang box labeled as Room Unit X X is the Room Unit number e Strip approximately 2 of insulation from the Cat 5e cable e Untwist cable pairs and place them next to each other in color coded order according to the T568A standard and insert the wires into an RJ45 plug e Crimp the RJ45 plug onto the cable with a proper R
25. n Q enclosure or any On Q module or device in an unheated garage attic or outside wall Do not expose any inQuire 1000 Intercom System component that was designed for indoor use to moisture Doing so can create electrical hazards or render the component unusable Exposure to moisture will also void the warranty on the system Only use On Q Legrand authorized components modules and devices with the inQuire 1000 Intercom System Not doing so will void the warranty of the system Only use a damp cloth to clean the cover plates of the system components Do not use vacuum cleaners liquid or aerosol cleaners to clean any of the system components 301 Fulling Mill Road Suite G Copyright 2006 by On Q Legrand Inc Page 1 Middletown PA 17057 All Rights Reserved 800 321 2343 www onglegrand com Ci legrand ll System Components Overview E Door Unit A System Components Please refer to Figure 16 to familiarize yourself with the operation of the The following components in addition to a suitable power supply are typically utilized to make up the inQuire 1000 Intercom System see Figure 1 inQuire 1000 Door Unit Door Chine Buton Wen a visitor pushes this button the Door Chime Wil be neard throughout the hone at each active intercomunit The occupants of the hone can then press the Door button at any intercom unit to answer the door The visitor will hear the occupant over the Door Unit speaker and be able t
26. n electrical storm There may be a risk of electric shock from lightning It is recommended that the customer install an AC surge protector in the AC outlet to which this device is connected This is to avoid damaging the equipment by local lightning strikes and other electrical surges e Operate this product only from the type of power source indicated on the product s marking label e If you are not sure of the type of power supplied to your home consult your dealer or local power company e Upon completion of any service or repairs to this product ask the service technician to perform safety checks to determine that the product is in safe operating condition Installation of this product must be in accordance with national wiring codes and conform to local regulations Wipe the unit with a clean dry cloth Never use cleaning fluid or similar chemicals Do not spray cleaners directly on the unit or use forced air to remove dust Keep the device away from excessive heat and humidity and keep the device free from vibration and dust 301 Fulling Mill Road Suite G Copyright 2006 by On Q Legrand Inc Page i Middletown PA 17057 All Rights Reserved 800 321 2343 www onglegrand com Ci legrand Table of Contents l Installation Safety Precautions ccccticcpecencecacccechecnctincecetectecaniaensceattcetesnensnnsndbertecsrecescoeeudeadbaunnnceds 1 i System Components OVER OW ssisiccisntseencenincsacmnsneandanegeddnndesatnansanceeseesanes
27. n the pairs between the punchdown block and the start of the cable insulation SE mu P A pnt th D Le am ef BR A a R Ge Ae wr nninmr sh on ge CR ch S 2 max untwisting Figure 3 Trim Out Patio Unit s see Figure 8 As shown in the diagram the Cat 5e cable must be terminated so that the cable is routed to the punchdown block so that the unit can be installed into a standard gang box while maintaining proper bend radius Following T568A wiring color code place the pairs firmly into their appropriate positions on the punchdown block Ensure that the individual conductors are seated tightly enough to allow you to punch them down without having to hold them in place Using a punchdown tool with a 110 style cutting blade punch down each conductor firmly enough to allow any excess conductor to be cut away by the blade Insert the Patio Unit and the Cat e5 cable into the 2 gang box and secure the unit to the box using the 4 included screws Door Unit s The procedure to trim out the Door Unit s is as follows Make sure that the included weather proofing gasket is placed over the Door Unit circuit board and speaker before terminating the Cat 5e cable see Figure 9 Locate the Cat 5e cable in the roughed in 2 gang box that you labeled as Door Unit X where X is the door unit number Strip back approximately 2 of insulation from the Cat 5e cable 301 Fulling Mill Road Suite G Copyright 20
28. o talk to them over the Door Unit rricrophone The occupant may also choose to release the electronic door latch if equipped and let the visitor in Figure 16 inQuire 1000 Door Unit Operation Figure 1 inQuire 1000 IntercomSystemConponerts e Intercom Module This module is typically installed in the On Q enclosure and is considered the brains of the system All Room Units Door Units Patio Units and the Main Console Unit are connected directly to the Intercom Module via home run style Cat 5e cabling The Intercom Module also supplies power to the entire inQuire 1000 Intercom System e Main Console Unit In addition to providing the same basic intercom features found with Room Units the Main Console Unit also includes a bank of status LEDs which show at a glance Room Units that are talking muted or in monitor mode It also includes a dedicated door release button functional when an electronic door release device is installed and a talk hands free button which allows users of Room Units to talk without having to push their talk buttons e Room Unit This unit provides basic intercom communication functions such as talk talk to door if Door Unit is installed monitor and mute Up to 12 Room Units can be installed per system e Desktop Unit This unit provides the same functionality as a Room Unit but can be placed on a desktop or nightstand instead of being installed in the wall It is connect
29. oOooodeoooo Deooooooo 2oxoooeosooo So000 MUTE Press this button once to put the Unit in MUTE node Press the button again to retum the Unit back to nomal noce While in MUTE mode both the speaker and microphone of the unit will be inactive and the LED to the right of the MUTE button will glow red MUTE node is useful for maintaining privacy in a particular room Multiple rooms can be in MUTE rock at the sane tire DOOR RELEASE There is no specific button on the Desktop Unit for the DOOR RELEASE function However by depressing both the TALK and the DOOR buttons at the sarre tirre the Unit will engage the door release device not induded with the IntercomSysten if a door release device is installed in conjunction with the IntercomSystem Once you let go of the TALK and DOOR buttons the door release device will be disengaged which will lock the door again ANSWER LED This LED is located at the top of the keypad of the RoomUnit Wren lit the LED indicates that the microphone in the unit is active and anything you say will be communicated through the system This LED will light when you are depressing the TALK or DOOR buttons The LED will be constantly lit when the unit is in MONITOR node DOOR Depressing this button will allow you to contrunicate with all Door Units that are part of your system Hold in the DOOR button while speaking and let itgo when you are done Your voice will be heard on any active Room Patio or Desktop
30. of the 2 gang box may not be obvious to the masonry contractor Ensure that the masonry contractor knows which edge of the box is up and which edge is down so that the Door Unit can be installed in the correct vertical position e The 2 gang box should be installed by the masonry contractor so that it protrudes slightly from the face of the brick The box should protrude no less than 1 8 but no more than 1 4 from the face of the brick Vinyl or wood based siding material exteriors e The 2 gang box can be roughed in to the exterior of the home by first cutting an opening through the exterior base material of the home that is slightly larger than your 2 gang box e The 2 gang box should then be securely mounted to the interior framing of the exterior wall and protrudes through the exterior wall at a depth that will need to be determined based on the type of siding that will finish the outside of the wall e Ideally you would want the siding contractor to use flashing and make use of J channel around the perimeter of the Door Unit and 2 gang box to provide an attractive and weatherproof siding installation Siding contractors should use flashing and J channel around the perimeter of the Door Unit just as they would with a window e Communication with the siding contractor is highly recommended to ensure a smooth installation ONE Cat 5e run is required to operate the Door Unit Untwist cable pairs but be sure to leave 1 2 twist i
31. on o Li legrand inOuire M 1000 Installation Guide 1307881 Rev O Federal Communications Commission Statement This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions e This device may not cause harmful interference and This device must accept any interference received including interference that may cause undesired operation This equipment has been tested and found to comply with the limits for a class B digital device pursuant to Part 15 of the Federal Communications Commission FCC rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures e Reorient or relocate the receiving antenna e Increase the separation between the equipment and receiver e Connect the equipment into an outlet on a circuit different from that to which the receiver is connected e Consult the dealer or an experience
32. otal Door Units will be used then the third Door Unit cable must plug into the jack labeled 12 DOOR 3 on the Intercom Module and you must remove a shorting block from pin 1 of JP100 on the rear of the Intercom Module see Figure 11 e Pin 2 of JP100 controls whether you want to hear the chime sound associated with the optional Door Chime at the Door Unit or not If you do want to hear the Door Chime at the Door Unit when the doorbell button is pressed remove the jumper from pin 2 see Figure 11 e Pin 3 of JP100 is associated with Patio Unit functionality If you are using a Patio Unit plug it into port 11 PATIO UNIT and remove the jumper from pin 3 of JP100 This is also called Security Mode and allows the Patio Unit to be temporarily disabled from the Main Console by simultaneously pressing the TALK and DOOR RELEASE buttons If the jumper on pin 3 is left on port 11 is configured to support a standard Room Unit NOTE For obvious security reasons there is no door release function enabled on a Patio Unit e _ Apply power to the Intercom Module and verify system functionality 301 Fulling Mill Road Suite G Copyright 2006 by On Q Legrand Inc Page 18 D Middletown PA 17057 All Rights Reserved 800 321 2343 www onglegrand com Ci legrand To avoid damage from debris during or after construction use an enclosed gang box The 3 gang box should be installed at the same height as electrical switch boxes in the home
33. roomwll be heard throughout the system The LED to the right of the MONITOR button will glow green when in MONITOR mode Multiple Units can be in MONITOR mode at the sane tine This function is useful for baby monitoring or other types of situations which require any voice or noise in a roomto be heard throughout the system NOTE When in MONITOR mock a door ball button push ata Door Unit will not result in a door chime ring at the Room Unt VOLUME There are wo volurre control buttons with an associated volurre level LED bar There are 20 differert volurre levels which are adjusted up and down using these two buttons Pressing the volunre up button once will increase the volurre one level higher You may not see the LEDs change until you press the volurre up or down multiple tines approximately every sixth button press You can also hold in the volurre up or down button until you have reached the desired volurre level It is recommrended that you keep the volurre level in the middle position 3 LEDs lit for optinnumsound Quality KEYPAD BRIGHINESS If the default Dimlevel of the backlit buttons is not adequate for the user then press both Volurre buttons at the sane tine and release them Use the Up or Down Volume button to brighten or dimthe default backlight level When the desired level is reached either push both buttons at the sane tine again to resurre normal operation or just let the Unit tine out after about 10 seconds to ret
34. s this button once to put the Unitin MONITOR mode Press the button again to reum the Unit back to normal node While in MONITOR noce the nicrophone is constantly active the speaker is disabled and any voice or noise within the roomwll be heard throughout the system The LED to the right of the MONITOR button will glow green when in MONITOR mode Multiple Units can be in MONITOR mode at the sane tine This function is useful for baby monitoring or other types of situations which require any voice or noise in a roomto be heard throughout the system NOTE When in MONITOR mode a door bell button push at a Door Unit will not resultina door chime rina at the Patio Unit VOLUME There are wo volure contro buttons with an associated volurre level LED bar There are 20 differert volurre levels which are adjusted up and down using these two buttons Pressing the volunre up button once will increase the volurre one level higher You may not see the LEDs change until you press the volurre up or down multiple tines approximately every sixth button press You can also hold in the volurre up or down button until you have reached the desired volurre level It is recommrended that you keep the volurre level in the middle position 3 LEDs lit for optimunnsourxl Quality MUTE Press this button once to put the Unit in MUTE node Press the button again to retum the Unit back to nomal noce While in MUTE mode both the speaker and microp
35. t s The procedure to rough in the Patio Unit s is as follows e Typically the Patio Unit s will be installed on the exterior of the home next to a patio door Verify the Patio Unit s location s with the homeowner before proceeding e Since the Patio Unit will most likely be installed on the exterior of the home and will be exposed to weather conditions these instructions must be followed to ensure a quality installation Brick or other cement based material exteriors e The recommended box to use is a 2 gang outdoor weatherproof box This box should be of the type that is made of heavy die cast aluminum Using a heavy die cast aluminum box will provide adequate strength in a brick or cement based exterior Vinyl or wood based siding material exteriors e If possible use a heavy duty die cast aluminum 2 gang box if it can be securely mounted to the interior framing If this is not possible then it is recommended that you use a heavy duty metal 2 gang box that can be securely mounted to the interior framing of the home e To ensure the 2 gang box that will be used to house the Patio Unit is roughed in correctly communication with the building contractor who is responsible for the exterior finish of the home is highly recommended Brick or other cement based material exteriors e The masonry contractor must be provided with specific instructions as to how the 2 gang box should be installed including location correct positionin
36. terior wall at a depth that will need to be determined based on the type of siding that will finish the outside of the wall e Ideally you would want the siding contractor to use flashing and make use of J channel around the perimeter of the Patio Unit and 2 gang box to provide an attractive and weatherproof siding installation Siding contractors should use flashing and J channel around the perimeter of the Patio Unit just as they would with a window e Communication with the siding contractor is highly recommended to ensure a smooth installation e ONE Cat 5e run is required to operate the Patio Unit e Run ONE Cat 5e cable from the 2 gang box directly to the enclosure where the Intercom Module will be installed Label both ends of your cable run to indicate Patio Unit Follow the wiring guidelines listed in this manual to ensure a quality cable installation NOTE The Patio Unit should be connected to the RJ45 jack that is labeled 11 PATIO UNIT This will reduce the maximum number of Room Units that can be installed from 12 to 11 Door Unit s The procedure to rough in the Door Unit s is as follows e Typically the Door Unit s will be installed on the exterior of the home next to an entrance door where you would normally find a standard doorbell Verify the Door Unit s location s with the homeowner before proceeding e Since the Door Unit will most likely be installed on the exterior of the home and will be exposed to weather
37. thing with sharp edges that could cause damage Clearly label all cabling runs at both ends Use the distance between your hand and your elbow as a guide to determine how far from the end of the cable to place the label C Unit Placement Tips Carefully plan the placement of Room Units and the Main Console Unit before rough in to avoid any feedback issues that are associated with audio devices To minimize the likelihood of any feedback issues avoid placing units back to back on a common wall If units must be placed on both sides of a common wall then do so in a manner which avoids feedback problems Do not place intercom units within the same room in the home Avoid any situations where the speaker of a unit points to and has a Clear line of sight to another unit s microphone D Termination Instructions All termination can be correctly completed by following the T568A pin assignments It is important that you accurately terminate using T568A at all on o Ci legrand 301 Fulling Mill Road Suite G Copyright 2006 by On Q Legrand Inc Page 4 Middletown PA 17057 All Rights Reserved 800 321 2343 www onglegrand com TALK Depressing this button will allow you to contrunicate with all other active units Hold in the TALK button while speaking and let it go when you are done Your voice will be heard on the Main Console Unit as well as any active Room Patio or Desktop Unit within the system OWS oc Oc ST o O
38. ttons is not adequate for the user then press both Volune buttons at the sane tine and release them Use the Up or Down Volume button to brighten or dimthe default backlight level When the desired level is reached either push both buttons at the sane tine again to resurre norrrel operation or just let the Unit time out after about 10 seconds to retum to normal operation NOTE When in use the Units backlight level is at full brightness and retums to the set backlight Dimlevel upon timeouk about 10 seconds Page 19 NOTE Only door release devices that operate using 12V DC and have a maximum current draw of 500mA are to be used with the inQuire 1000 Intercom System Figure 11 Install Intercom Module into Enclosure e Insert the Intercom Module into the mounting bracket and insert the bracket into the On Q enclosure Secure the Intercom Module to the bracket by depressing each plunger at each corner of the Intercom Module e DO NOT apply power to the Intercom Module until all RJ45 plugs are seated in the correct jacks on the Intercom Module e Plug in all RJ45 connectors for Room and Desktop Units into the appropriate jacks on the Intercom Module according to your cable labeling e If utilized plug the RJ45 connector for the Patio Unit into the jack labeled 11 PATIO UNIT on the Intercom Module e The Main Console Unit cables should plug into the correct MAIN jacks according the the cable labeling e If 3 t
39. um to nomal operation NOTE When in use the Units backlight level is at full brightness and retums to the set backlight Dimlevel upon timeout about 10 seconds Page 20 locations There are two different types of terminations you will encounter when installing the inQuire 1000 Intercom System RJ45 plugs and 110 punchdown blocks Refer to the diagrams below see Figure 2 which show the correct T568A termination for both RJ45 plugs and 110 punchdown blocks RJ45 Plug Top View Wire Order Brown White Brown Orange White Blue Bue Wivte Orange Green Wiring Channels WheteGreen 110 Punch Down Strip green white green orange white orange blue Y white blue Figure 2 T569A Tennination Color Code Reference 301 Fulling Mill Road Suite G a Middletown PA 17057 800 321 2343 Ci legrand Copyright 2006 by On Q Legrand Inc All Rights Reserved www onglegrand com Page 5 IV System Wiring Overview V System Operational Overview A Pre Wiring Rough In The following section explains the various functions and operational features of the The rough in of the inQuire 1000 Intercom System should be completed components of the inQuire 1000 during the construction phase of the home and prior to the installation by the A Main Console Unit home builder of any wall covering such as drywall The following section will instruct you on the proper methods to pre wire your cable and rough
40. ure that will house the Intercom Module and Door Chime will need to be completed per the enclosure s installation instructions There is no further rough in work reguired for the Intercom Module and the Door Chime since these components will mount directly in the On O Enclosure during trim out NOTE The Door Chime mounts onto the back of the Intercom Module and does not reguire its own separate enclosure space 301 Fulling Mill Road Suite G Copyright 2006 by On G Legrand Inc Page 11 Middletown PA 17057 All Rights Reserved 800 321 2343 www onglegrand com B Final Wiring Trim Out The trim out of the system should be completed after wall coverings have been finalized The following section will instruct you on the proper methods to finish the installation of the various inQuire 1000 Intercom System components 1 Main Console Unit The procedure to trim out the Main Console Unit is as follows on o Ci legrand Locate the Cat 5e cable in the roughed in 3 gang box that you labeled as Main 1 Strip back approximately 2 of insulation from the Cat 5e cable Untwist cable pairs and place them next to each other in color coded order according to the T568A standard and insert the wires into an RJ45 plug Crimp the cable into the RJ45 plug with a proper RJ45 crimp tool Plug the terminated Main 1 cable into the RJ45 jack on the rear of the Main Console Unit Main 1 see Figure 4 Main packs Figure 4 inQu
41. ut away by the blade e Snap the insert into the wallplate or strap and secure them in the 1 gang box using the included screws Attach a 1 gang plate if necessary to complete the installation e Plug the Desktop Unit into the installed Cat 5e outlet e Repeat these instructions for all the Desktop Units in your inQuire 1000 Intercom System Patio Unit s The procedure to trim out the Patio Unit s is as follows e Locate the Cat 5e cable in the roughed in 2 gang box that you labeled as Patio Unit e Strip back approximately 2 of insulation from the Cat 5e cable 301 Fulling Mill Road Suite G Copyright 2006 by On G Legrand Inc Page 14 Middletown PA 17057 All Rights Reserved 800 321 2343 www onglegrand com on o Ci legrand e Run ONE Cat 5e cable from the 2 gang box directly to the enclosure where the Intercom Module will be installed Label both ends of your cable run to indicate Door Unit number ex Door Unit 1 Follow the wiring guidelines listed in this manual to ensure a quality cable installation e Repeat these instructions for each and every Door Unit that will be installed in the system maximum of 3 NOTE Up to three Door Units can be installed The installation of a third Door Unit requires that you use the RJ45 jack that is labeled 12 DOOR 3 This will reduce the maximum number of Room Units that can be installed from 12 to 11 Intercom Module and Door Chime The rough in of the On O Enclos
42. you to punch them down without having to hold them in place e Using a punchdown tool with a 110 style cutting blade punch down each conductor firmly enough to allow any excess conductor to be cut away by the blade e Insert the Door Unit with the gasket in position and the Cat e5 cable into the 2 gang box and secure the unit to the box using the 4 included screws e Repeat these instruction for any additional Door Units in your inQuire 1000 Intercom System Door Chime The procedure to install the Door Chime is as follows e The Door Chime circuit board installs onto the rear circuit board of the Intercom Module NOTE Remove power from the front of the Module before installing the Door Chime 301 Fulling Mill Road Suite G Copyright 2006 by On Q Legrand Inc Page 16 Middletown PA 17057 All Rights Reserved 800 321 2343 www onglegrand com on o Ci legrand e The 2 gang box should be installed by the masonry contractor so that it protrudes slightly from the face of the brick The box should protrude no less than 1 8 but no more than 1 4 from the face of the brick Vinyl or wood based siding material exteriors e The 2 gang box can be roughed in to the exterior of the home by first cutting an opening through the exterior base material of the home that is slightly larger than your 2 gang box e The 2 gang box should then be securely mounted to the interior framing of the exterior wall and protrudes through the ex