Contents
1. 4 2 1 Control Feature iia 4 2 2 Display Features joss a ei 5 2 3 Button Functions ela 5 2 3 1 HOLD PEAK Buttons diee eene etes 5 232 ZERO Bull tada 5 3 5 0 6 rra 6 3 1 Electrical Specifications 6 3 2 Environmental 7 3 3 Mechanical SpecificatioNS 8 3 4 Safety 8 4 OPERATION rra 9 4 1 Preparation Before 9 4 2 AC Current Measurement 10 43 DC Current 11 4 4 AC Voltage 12 4 5 DC Voltage MeasuremMent 13 4 6 Resistance 14 4 7 Continuity 15 4 8 Analog OUultpUt eiecti tente aaa 16 5 17 Set ANSIRIDO a ale Ba UAM ir da 17 5 2 Battery Replacement eene 17 MENGE M 17 Repair and Calibration n tete e ed e yee 18 Technical and Sales Assistance sess 18 Limited Warranty neant demo ee eie eL 19 Warranty Repas geia pede deben o HR aa
2. ie 19 CHAPTER 1 INTRODUCTION A Warning A These safety warnings are provided to ensure the safety of personnel and proper operation of the instrument Read the instruction manual completely and follow all safety infor mation before operating this instrument Only use leads that comply with the IEC EN 61010 Before using them make sure that they are in safe working order Only use factory supplied leads Never exceed the protection limit values indicated in the specifica tions for each type of measurement Never measure current while the test leads are connected to the input jacks Use extreme caution when measuring live systems with voltages greater than 50VDC or 30VAC Do not perform resistance or continuity tests on a live circuit Use extreme care when working around bus bars and bare conduc tors Do not use the meter in overrange overload conditions OL When the multimeter clamp is linked to the measurement circuits do not touch any unused terminals Before changing the function disconnect the measurement leads from the circuit measured 2 AC Clamp on Meter Model CM605 1 1 International Electrical Symbols This symbol signifies that the instrument is protected by double or rein E forced insulation Use only specified replacement parts when servicing the instrument This symbol on the instrument indicates a WARNING and that the A operator must refer to the user manual for instruc
3. AC DC LOW CURRENT 6 0 5 CLAMP ON METER USA equipment PNET 4 1 877 742 TEST 8378 AEMC User Manual INSTRUMENTS Statement of Compliance Chauvin Arnoux Inc d b a AEMC Instruments certifies that this instrument has been calibrated using standards and instruments traceable to international standards We guarantee that at the time of shipping your instrument has met its published specifications An NIST traceable certificate may be requested at the time of purchase or obtained by returning the instrument to our repair and calibration facility for a nominal charge The recommended calibration interval for this instrument is 12 months and begins on the date of receipt by the customer For recalibration please use our calibration services Refer to our repair and calibration section at www aemc com Serial Catalog 7000 02 Model 605 Please fill in the appropriate date as indicated Date Received Date Calibration Due Chauvin Arnoux Inc d b a AEMC Instruments INSTRUMENTS www aemc com ceo de ptes A Table of Contents 1 2 1 1 International Electrical SymbolSs 3 1 2 Receiving Your 3 1 3 Ordering 3 2 PRODUCT FEATURES
4. 71 x 37mm Weight 6 5 oz 180g 3 4 Safety Specifications IEC EN 61010 1 600V CAT II 300V CAT III Insulation Class II Pollution Degree 2 Clamp on Meter Model 605 CHAPTER 4 OPERATION 4 1 Preparation Before Use For your own safety and to prevent damage to the instrument follow the instructions given in this manual This instrument can be used for measurements e circuits in installation Category Il in an environment with pollution level 2 for voltages no greater than 600V in relation to the earth e or on circuits in installation Category III in an environment with pollution degree level 2 for voltages no greater than 300V in relation to the earth Definition of the installation categories see IEC EN 61010 1 publication CAT Il CAT Il circuits are household or similar appliance power circuits which may carry medium level transient over voltage Example household appliance and portable tool power supplies CAT CAT circuits are high power appliance power circuits which may carry high level transient over voltage Example industrial machinery or instrument power supplies For your own safety only use factory supplied leads and always check that they are in perfect working order AC Clamp on Meter Model CM605 9 4 2 AC Current Measurement Tum the switch to the range e Remove the test leads before measuring current Clamp the jaws around the conductor to be
5. Display Features Negative polarity AUTO A D E 23000 Auto shutdown Low battery AC mode DC mode AUTO Auto range m I A a Q Zero Relative Peak function Hold function Continuity Current Voltage Resistance 2 3 Button Functions 2 3 1 HOLD PEAK Button Data Hold Function This function locks the displayed value To activate press this button during the measurement symbol appears and the measurement is locked To deactivate press the button again Peak Hold Function This function displays the peak value To activate press this button during a measurement until the 2 symbol appears The highest measurement is stored in memory To deactivate the PEAK function press and hold down the button for approximately 2 seconds 2 3 2 ZERO Button To activate press the ZERO button to enter the Zero mode The A symbol will appear and Zero the display The reading is stored as a reference value for subsequent measure ments To exit the Zero mode press the ZERO button again AC Clamp on Meter Model CM605 5 CHAPTER 3 SPECIFICATIONS 3 1 Electrical Specifications Reference Conditions Accuracy given 23 C 5 C 80 RH Max Conductor centered in jaws 45 65Hz No DC Component AC Current A 50 to 500Hz 80A 2 0 R 10cts 109A 80A 3 5 R 10cts DC Current A Positive only 80A 2 5 R 10cts AC Volts V Resolution 6
6. measured Take the current reading after it stabilizes A WARNING Immediately remove the test probes from the circuit under test if overload OL is displayed CORRECT INCORRECT two conductors from different phases 10 AC Clamp on Meter Model CM605 4 3 DC Current Measurement NOTE Remove the test leads before measuring current Turn the rotary range switch to the A range f needed the display may be zeroed Press the ZERO button to zero the read ing Press the lever to open the jaws Clamp the jaws around the conductor to be measured If reading is unstable and is hard to read push the HOLD button and read the measurement AN WARNING Immediately unclamp the meter from the conductor under test if overload GL is displayed AC Clamp on Meter Model CM605 11 4 4 AC Voltage Measurement Automatic measurement range 600VAC DC Tum the switch to the V range Insert the red lead to the red input jack and the black lead to the black COM input jack Bring the test probe tips into contact with the test points Take the voltage reading after it stabilizes A WARNING Immediately remove the test probes from the circuit under test if overload OL is displayed
7. probe tips into contact with the sample under test The buzzer sounds when the circuit to be checked is DC or has resis tance of less than 1000 250 A WARNING If overload OL is displayed the continuity exceeds the measurement range or the circuit is open AC Clamp on Meter Model CM605 15 4 8 Analog Output Turn the rotary switch to the A or range Insert the red lead to the red input jack and the black lead to the black COM input jack Connect the ends of both cables to an oscilloscope or another multimeter Clamp the jaws around the conductor to be measured Read the analog signal on the oscilloscope or multimeter If the signal measured is continuous the output signal will be DC If the signal measured is alternating the output signal will be AC 16 AC Clamp on Meter Model CM605 CHAPTER 5 MAINTENANCE 5 1 Warning A Remove the test leads from any input before opening the case Do not operate the instrument without a battery case cover To avoid electrical shock do not attempt to perform any servicing unless you are qualified to do so If the meter is not going to be used for a long period of time take out the batter ies Do not store the meter in high temperatures or high humidity To avoid electrical shock and or damage to the instrument do not get water or other for
8. 00V 100mV 1 5 5 10M9 lt 50pF 40 to 500Hz Overload Protection 660Vrms DC Volts V Positive only Input Impedance 600V 100mV 1 0 R 2cts Overload Protection 660Vrms For negative measurement add 2cts to the accuracy o AC Clamp on Meter Model CM605 Resistance Q Test Voltage 10 99990 1 0 R 3cts 600Vrms Continuity 1 Test Voltage Analog Output Range Output Frequency Output Impedance Aac amp Apc through o to 20kHz 3db 3kQ lt 50pF front banana jacks Digital display 10 000 count 4 digit LCD display 9999 max Polarity When a negative signal is applied the agi symbol appears Overload If the range is exceeded the GL symbol is displayed Low Battery Indicator is displayed when the voltage supplied by the batteries is lower than the operat ing voltage Power Supply 2 batteries 1 5V type AAA LR03 Auto off Automatic shut down after approx 10 minute with over ride Sampling Approx 2 measurements second 3 2 Environmental Specifications Operating Temperature 32 to 104 F 0 to 40 C lt 80 RH max non condensing Storage Temperature 14 to 140 F 10 to 60 C lt 70 RH max non condensing Altitude 6000 ft 2000m AC Clamp on Meter Model CM605 7 3 3 Mechanical Specifications Maximum Cable Diameter 0 45 12mm Maximum Jaw Opening 0 60 15mm Dimensions 7 44 x 2 80 x 1 46 189 x
9. 03820 USA Tel 800 945 2362 Ext 360 603 749 6434 Ext 360 Fax 603 742 2346 or 603 749 6309 repair aemc com Or contact your authorized distributor Costs for repair standard calibration and calibration traceable to N 1 S T are available NOTE You must obtain a CSA before returning any instrument Technical and Sales Assistance If you are experiencing any technical problems or require any assistance with the proper operation or application of your instrument please call mail fax or e mail our technical support team AEMC Instruments 200 Foxborough Boulevard Foxborough MA 02035 USA Phone 800 343 1391 508 698 2115 Fax 508 698 2118 techsupport aemc com www aemc com NOTE Do not ship Instruments to our Foxborough MA address 18 AC Clamp on Meter Model CM605 Limited Warranty The Model CM 605 is warranted to the owner for a period of one year from the date of original purchase against defects in manufacture This limited warranty is given by AEMCS not by the distributor from whom it was purchased This warranty is void if the unit has been tampered with abused or if the defect is related to service not performed by AEMC For full and detailed warranty coverage go to www aemc com The war ranty information is located in our customer service section What AEMC will do If a malfunction occurs within the one year period you may return the instrument to us for repair provided you s
10. EJ HOLD Press El PEAK ec OFF 12 AC Clamp on Meter Model CM605 4 5 DC Voltage Measurement Automatic measurement range 600VAC DC Turn the switch to the V range Insert the red lead to the red input jack and the black lead to the black COM input jack Take the voltage reading after it stabilizes A WARNING Immediately remove the test probes from the circuit under test if overload OL is displayed AC Clamp on Meter Model CM605 13 4 6 Resistance Measurement Automatic measurement ranges 0 to 10kQ A WARNING When making a resistance measurement make sure that the power is off dead circuit It is also important that all capacitors in the measured circuit be fully discharged e the rotary switch to the range Insert the red lead to the red input jack and the black lead to the black COM input jack Bring the test probe tips into contact with the sample under test A WARNING If overload OL is displayed the resistance exceeds the measurement range or the circuit is open HHI 14 AC Clamp on Meter Model CM605 4 7 Continuity Test WARNING When testing continuity make sure that the power is off dead circuit e the rotary switch to the range Insert the red lead to the red input jack and the black lead to the black input jack Bring the test
11. eign agents into the probe 5 2 Battery Replacement The batteries will need to be replaced when the symbol appears on the display The meter must be in the OFF position and disconnected from any circuit or input Remove the battery cover screws with a screwdriver Replace the old batteries with two new 1 5V AAA LR03 batteries Replace the battery compartment cover and tighten the screws 5 3 Cleaning To clean the instrument wipe the case with a damp cloth and mild detergent Do not use abrasives or solvents Do not get water inside the case This may lead to electrical shock or damage to the instrument AC Clamp on Meter Model CM605 17 Repair and Calibration To ensure that your instrument meets factory specifications we recommend that it be scheduled back to our factory Service Center at one year intervals for recalibration or as required by other standards or internal procedures For instrument repair and calibration You must contact our Service Center for a Customer Service Authorization Number CSA This will ensure that when your instrument arrives it will be tracked and processed promptly Please write the CSA on the outside of the shipping container If the instrument is returned for calibration we need to know if you want a standard calibration or a calibration traceable to N 1 S T Includes calibration certificate plus recorded calibration data Ship To AEMC Instruments 15 Faraday Drive Dover NH
12. tions before operating the instrument In this manual the symbol preceding instructions indicates that if the instructions are not followed bodily injury installation sample and product damage may result a Risk of electric shock The voltage at the parts marked with this symbol may be dangerous 1 2 Receiving Your Shipment Upon receiving your shipment make sure that the contents are consistent with the packing list Notify your distributor of any missing items If the equipment appears to be damaged file a claim immediately with the carrier and notify your distributor at once giving a detailed description of any damage Save the damaged packing container to substantiate your claim Do not use an instrument that appears to be damaged 1 3 Ordering Information Model CM605 sss treten Cat 7000 02 Includes clamp on meter lead set red amp black lead with needle point test probes carrying case 2x1 5V AAA batteries and a user manual AC Clamp on Meter Model CM605 3 CHAPTER 2 PRODUCT FEATURES 2 1 Control Features 1 Tapered jaws for crowded wiring or areas 45 12mm 2 Safety barrier anti slip guard 3 Lever for jaw opening closing 4 LCD display 5 COM Black and Positive Red input terminal jacks 2 6 Data hold and Peak hold BJ AER buttons 7 Rotary range selector switch EL CM 605 METER com A 600v OT 4 AC Clamp on Meter Model CM605 2 2
13. ubmit a proof of purchase AEMC will at its option repair or replace the faulty material Warranty Repairs What you must do to return an Instrument for Warranty Repair First request a Customer Service Authorization Number CSA by phone or by fax from our Service Department see address below then return the instrument along with the signed CSA Form Please write the CSA on the outside of the shipping container Return the instrument postage or shipment pre paid to AEMC Instruments Service Department 15 Faraday Drive Dover NH 03820 USA Tel 800 945 2362 Ext 360 603 749 6434 Ext 360 Fax 603 742 2346 or 603 749 6309 Caution To protect yourself against in transit loss we recommend you insure your returned material NOTE You must obtain a CSA before returning any instrument AC Clamp on Meter Model CM605 19 Notes 20 AC Clamp on Meter Model CM605 E AEMC INSTRUMENTS 11 09 99 MAN 100346 v1 SA 2 B pum D 205 Westwood Ave Long Branch NJ 07740 1 1 877 742 8378 732 222 7088 e pow salesteam Tequipment NET