1. 3 2 FPU operation Instructions and regulations e In view of our experience we strongly recommend that each employee practices finger positioning on the sensor prior to actual enrollment e Avoid using thumb and pinky fingers since they are typically awkward to position consistently on the sensor e Place the higher joint of your finger on the ridge lock and lower your fin ger onto the sensor surface make sure all other fingers are held straight to avoid creating an angle between the enrolled finger and the sensor sur face incorrect positioning e Touch the sensor s plastic casing black in order to discharge static elec tricity Keep your finger steady e Press your finger gently onto the panel avoid excessive pressure as it will blur the print e Make sure your finger is touching the sensor s drive ring e Itis recommended that quality be 50 and content 90 at least e Make sure you use the enrolled finger for verification e If your finger is extremely dry touch your forehead or the side of your nose before placing it on the sensor e Do not use a wet moist finger for scanning Note For user s convenience mount the terminal at a height of 1 4 meters 55 2 measured from the top end of the terminal to the floor and at a distance of 15 cm 5 9 from the right side wall closer to the sen sor side Note If it is impossible to sample an employee s fingerprint you can disa ble finger verification
2. 1 Swipe card According to opera card 2 Insert pin code tion mode press If Operation Mode is 4 7 amp 8simultaneously Terminal reverts to 1 Fingerprint Operation Mode 5 1 Swipe card 2 beeps confirm swipe 2 Place finger Terminal reverts to 1 in order to revert to normal mode press Enter in terminals that consist of an Enter key Mode 5 only with PRintX Delete card from list using card 21 Card Note After swiping all cards you should wait time out or press 7 amp 8 simultaneously press Enter in terminals that consist of an Enter key once Then all data will be saved Synel Industries Ltd Set up mode PRX 40 A Parameter Set up Function Comments Default Code Insert card using 22 1 Key in card According to opera keyboard 2 Insert pin code tion mode press In Operation Mode 12 7 amp 8 simultaneously press key no 4 in order to revert to Terminal revert to 1 normal mode press Enter in ter minals that consist Fingerprint In Operation of an Enter key Mode 12 press key no 6 1 Key in code depends Mode 6 only with on card length PRintX 2 Place finger Terminal reverts to 1 Delete card using 23 Card number keyboard Insert card by 24 1 Card index 4 digits Highest possible Index from 0000 0300 index depends on 2 Swipe card card length code In Operation Mode 12 11 press key no
3. characteristics e PRintX40AI_V Power supply 12Vdc 0 5A e PRintX Power supply SVdc 1A e Output relay rating 24 V 3 A e Tamper sensor output TTL level max 16 mA 2 5 Package e PRintX 40I_V proximity reader e PRintX biometric reader verification identification e PRintX P power supply adaptor 5 Volt 1 A stabilized wide range input 100 240 AC input 18 Synel Industries Ltd PRX40A Appendix A Fingerprint Unit RJ 11 Connection box with 5V power input RJ 45 Connection box Four 3 5x50mm Philips screws four 3 5x19mm Philips screws and four for position B four Brick Plastic anchors Mounting template User manual Recommended PRintX 40I_V Power supply adaptor 12 to 15 Vdc max 880 mA 3 Installation Front panel Note When working with PRintX40A I Identification you can install the PRintX on the external side of the door and the PRX40 on the internal side of the door Synel Industries Ltd 19 PRX40A Appendix A Fingerprint Unit iring W 3 1 1 ayou Sail 18Y 0 p abed uo gz ydeubered 0 18431 SAMA 194Y 0 10 SUONONISUI UONIAaUUOD 104 AON ang DIA NAROHA IHS US HAK axa ANDMIYTA N3349 YO HAA YO HAA MI1G HAA QXDSLIHAA lo 5 270079 OXDN33H9 LiTH axW SONvHO UONISUUOD AV 49 IV 0PXIUIHd Synel Industries Ltd 20 PRX40A Appendix A Fingerprint Unit
4. list type 35 1 Black list Rejected 0 0 White list Accepted Alarm mode 51 O Latch led is on 1 Led is off 1 Pulse led is off depending on pulse time code 52 Alarm pulse acti 52 0000 9999 You must always O sec vating time key in time ina four digit format 10 sec 0010 Door opening time 10 000 255 In 1 10 seconds step 3 sec 0 to 25 5 sec Communication 14 1 16 Defines terminal ID 01 ID Operation mode 12 0 Card only There isa 1 Global code only different 2 Card or code card no cS for 3 Card and global code ein employee 4 Card and pin code 5 Card and finger _ si 6 Code and finger fin Functions 5 6 only ger only with PrintX Synel Industries Ltd PRX 40 A Set up mode Parameter Set up Function Comments Default Code Duress code 50 0 Disable Activating alarm enable disable 1 Enable and relay output Define duress codel 53 0000 9999 Active in operation mode 1 2 3 4 Card reading 11 1 2 Offset 01 37 01 check parameters 3 4 Length 01 06 16 5 6 Total Characters 00 New master code 13 00000000 99999999 8 digit code Erase all cards 60 Type master code Initialisation of 61 Master Code 8 digits memory Vocal ID indica 7 Long buzzer for tens tion Short buzzer for uniques Reset alarm 4 When the alarm is in latch Control door 0 New global code 15 4digit new code 9999 Insert card using 20
5. order to revert to normal mode Delete cards After entering set up mode key in code 25 delete card by index and key ina 4 digit index 2 short beeps will indicate that the index was deleted success fully After swiping all cards press 7 amp 8 simultaneously mandatory press Enter in terminals that consist of an Enter key in order to revert to normal mode Terminology Card Only Control is performed by Card only Global Code only common global code 4 digit code used by all card holders Card or code Control is performed by Card or keying in number of card the length of the keyed in number must be identical to the defined card length Card and Global Code Control is performed by Card and a common global code four digit code used by all card holders Card and PIN Code Control is performed by Card and a personal four digit code This mode is the most secure 4 digit code used by each card holder 3 2 General definitions Open Door Access can be given by using a Master Code After entering Programming Mode enter 0 Open Door Time It is possible to adjust the window of accessability during which a door opens when accessed To change the accessability time after entering the Programming Mode enter 10 and then four digits For example if you enter 0015 the accessability time is 1 5 seconds Set Global Code You can change a Global Code by way of Instruction
6. 4 3 Insert pin code Delete card by 25 Card index 4 digits index Time Out After every entry a LED is lit while waiting for the next entry After the LED goes out the unit exits the Programming Mode and resets action must be repeated from the beginning 3 1 1 Management of Access Cards authorized personnel Managing access Cards can be performed three ways Using Keyboard Keying in the keyboard the card number Using Card Swiping the card By Index Enables deleting an employee without a card 10 Synel Industries Ltd PRX 40 A Set up mode Using Keyboard Build list After entering set up mode key in code 22 key in card number to list Up to 13 characters in Linear decoding and key in all relevant cards After each keyed in card number 2 short beeps will indicate that the number was regis tered successfully After keying in all card numbers press 7 amp 8 simulta neously mandatory press Enter in terminals that consist of an Enter key in order to revert to normal mode Note In operation mode 4 card and pin code the user must key in the card number and then key in the pin code for each card 4 digit code Delete list After entering set up mode key in code 23 Delete card by keyboard and key in all irrelevant cards After each keyed in card number 2 short beeps will indicate that the number was deleted successfully After keying in all card numbers press 7 amp 8 simu
7. Code 15 After 12 Synel Industries Ltd PRX 40 A Set up mode entering Programming Mode enter 15 and afterward a four digit number that will be the new Global Code Set New Master Code The Master Code can be change by way of Instruction Code 13 After entering Programming Mode enter 13 followed by a eight digit number that will serve as a new master Code Note It is recommended to change master code when setting up Erase All Warning Cards can not be restored after erased After entering the Programming Mode enter 6 and then eight digits Mas ter code 3 3 Indicators definitions After entering setup mode Input Operation Mode Code 30 gt 0 Door open request button As a result the door will open and the output bypass 1 Door sensor As a result the output alarm will be activated led buzzer Sensor type Code 31 gt 0 The sensor will function as Normally Open 1 The sensor will function as Normally Closed Alarm mode Code 51 gt 0 Latch The alram does not go off unless it is turned off manually 1 Pulse The alram goes off after the defined time out Alarm pulse activating time Note Relevant when alarm is in pulse mode Code 52 gt 0000 9999 seconds always key in time in 4 digits format Sensor door activating time Code 32 gt 000 255 time out seconds The alarm will be activated after the defined time out Synel
8. Industries Ltd 13 Set up mode PRX 40 A Duress code enable disable Code 50 gt 0 Disable 1 Enable In operation modes card and global code or card and pin code enables activating the alarm and the door simultaneously Define Duress code Code 53 gt 0000 9999 Enables defining what will be the duress code Card parameters Refer to how the proximity track will be read 2 digits Start position 01 37 Card number offset 2 digits Length 01 06 Card number length 2 digits Total characters Number of digits on card when defining 00 doesn t check card length accepts all card lengths upto 6 Reset alarm In set up mode after keying in code 51 key in 4 to shut off the alarm 14 Synel Industries Ltd PRX 40 A Communication 4 Communication Interfacing the host is performed via the Master unit Communication between the master unit and the terminals is performed at 19200 bps Downloading card numbers from Master to terminals As of Master version 3 20 there is an additional option Send offline list to Access units All card numbers that are marked as see Falcon Personnel Card Type Active Allowed offline Active Allowed offline will be sent from the Master to the terminals When communication is stopped the Termi nal will enable access for the cards as mentioned above PRX40A supports this option as of version 2 04 4 1 Communication cables characteristics Follow the listed guideline
9. PRX 40 A Proximity Reader Product Manual Synel Industries Ltd Manual was issued on 3 6 05 Catalog no 652745 Document no PRX40A 222 02 Copyright 2004 2005 Synel Industries Ltd All rights reserved This document has been prepared for controller firmware version 2 00 of the PRX40A proximity reader Reproduction or use without express permission of editorial or pictorial content in any manner is prohibited No patent liabil ity is assumed with respect to the use of the information contained herein While every precaution has been taken in the preparation of this manual Synel Industries Ltd assumes no responsibility for errors or omissions Nei ther is any liability assumed for damages resulting from the use of the infor mation contained here in SY is a trademark of Synel Industries Ltd All trade names referenced herein are either trademarks or registered trade marks of their respective companies PRX 40 A Introduction 1 Introduction The PRX 40 A proximity reader access unit is one of the compact access control unit series manufactured by Synel The card must be placed at a dis tance of about 10 cm from the device This reader can work as a stand alone reader or with a master controller con nected to upto 16 reader units It was developed as a compact easy to use proximity terminal granting access to secure areas The PRX 40 A works with various unit settings according to a predefined security level T
10. and revert to card or code mode instead 4 Maintenance You should always touch the conductive plastic before touching the PRintX sensor in order to safely discharge any static electricity on your skin or clothing Do not e Place the fingerprint sensor close to a heating source such as a radiator or hot plate e Spill any liquids on the sensor with the exception of isopropyl alcohol e Subject the fingerprint sensor to heavy shocks or vibrations e Allow the sensor to come in contact with metallic objects Synel Industries Ltd 21
11. at High Sensor Input 9 18V 10mA in Non dry contact mode Power supply 9 to 15 Vdc max 100 mA Door open request button the entry will enable opening the door Door sensor the sensor will indicate that the door was forcefully opened 16 Synel Industries Ltd PRX40A Appendix A Fingerprint Unit Appendix A Fingerprint Unit PRintX40AI V is a biometric stand alone controller one of the series of Synel s access control protocols It is a unit that operates with either a fingerprint verification version PRintX40AV or a fingerprint identification version PRintX40AI further to user card reading by the proximity unit The proximity and biometric units are adjacently installed at sensitive locations for granting access to secure areas The PRintX40AI V works with various unit settings according to the security level required at the location of the unit Defining parameters is simple while maximum security is enabled by using a password defined by the user Access is available for upto 1000 card holders in the verification version and upto 200 card holders in the identification version stored in an authorized list This list is created and edited using keyboard 1 Differences between PRintX40AI amp PRintX40AV e PRintX40AD Identification does not require a card code Upto 200 fin gerprint templates are stored in the terminal s memory Whenever an employee places his finger on the sensor the FP fingerp
12. ed 2 3 Closed AC DC JP24 T H Reset for the slave reader CPU 2 3 closed 2 3 closed Programming of the slave reader CPU 1 2 Closed 6 Synel Industries Ltd PRX 40 A Set up mode 3 Set up mode PRX 40 A programming can be divided to three categories 1 Access Cards configuration authorized personnel 2 General definitions 3 Indicator definitions All definitions of Management modes are listed in the table below The codes in the table below can be used only after completing set up mode as follows Step 1 Press 3 times simultaneously on function keys 1 amp 2 each time will be followed by a short beep and an orange led will be lit Input Indicator signalling Ist 1 amp 2 Short beep 2nd red led ON 2nd 1 amp 2 Long beep 2nd red led ON 3rd 1 amp 2 2 long beeps 2nd green led flashes Step2 Enter the 8 digit master code the default number is 12345678 Then insert the relevant set up code see next page Synel Industries Ltd 7 Set up mode PRX 40 A 3 1 Access cards configuration Parameter Set up Function Comments Default Code Sensor mode 30 0 Door open request Door 1 Door Sensor open request Sensor type 31 0 N O N C 1 NC Sensor door active 32 000 255 Define in 15 sec time open seconds Toggle relay mode 33 0 Disable In minutes Disable 1 Enable Toggle relay time 34 00 99 Define in 00 out seconds Disabled Card
13. far away as possible from electrical power source reference such as power equipment computers motors pumps etc e Ifyouareinstalling more than one Synel proximity reader make sure the readers are installed at a distance of at least 50 cm from one another a distance longer 5 times their reading limit e Near metal objects reading range may decrease e Use a linear power supplier and not a switching power supplier A switching power supplier auto generates an electro magnetic field that shortens the reading range It is advisable to connect an independant power supplier to the reader e Make sure that the reader is not in a metalic materials surroundings When mounting on a gypsum wall make sure that there is no rear met alic reinforcement If the reader is mounted on a concrete wall the reader must be mounted up to 20 cm from the wall e Itis recommended that when swiping the badge it will face the reader Thus the badge will receive maximal energy e Use a power adaptor dedicated to the proximity reader access unit Make sure the adapter carries a safety recognition marking UL CSA or CE 2 2 Mounting Option A 1 Remove screw covers and screws from top and bottom of the unit 2 Open the back of the unit 3 Drill both fastening holes at either end and one hole towards the center for the cable 4 Fasten the back of the unit to the wall 5 Connect the cable wires via middle hole or bottom hole option see diagram 6 C
14. his device is made of strong ABS plastic Defining parameters in PRX 40 A is simple while maximum security is enabled by using the set up 8 digit code the default number is 12345678 greatly improving security In stand alone mode PRX 40 A grants secure access for approximately 285 card holders stored in an authorized list within the terminal This list is cre ated and edited on the unit s compact keyboard eliminating the need of con necting to a computer When working in online mode as of Master version 3 20 the PRX40A unit uploads employee data from Master to its own memory and relay on this data when allowing rejecting an employee if the connection with Master is lost PRX40A can manage unauthorized black list or authorized white list employee lists for access control purposes 1 1 PRX 40 A Apparatus The proximity reader access unit may be mounted on a wall The enclosures include a PC board assembly Over and above operating as an access terminal the PRX 40 A terminal has additional circuitry for storing card holder data Operating power for the unit is obtained from a wall adapter Synel Industries Ltd 1 Installation PRX 40 A Di Installation 2 1 General The PRX 40 A proximity unit can be installed in any building The back panel of the unit serves as an installation template Mounting screws and anchors are also provided Follow the guidelines below e The installation location selected should be as
15. lose the unit 7 Replace the screw covers 2 Synel Industries Ltd PRX 40 A Installation Option B 1 Remove screw covers and screws from top and bottom of the unit 2 Hold the unit against the wall and mark the drilling location through the screw holes 3 If the cable wires use the middle hole option remove the back panel and use it to mark the position of the cable hole center of panel Drill the cable hole in the wall 4 Drill the two fastening holes in the wall 5 Connect the cable wires via middle hole or bottom hole option see diagram as required 6 Fastened the unit to the wall with screws provided 7 Replace the screw covers aoe lt a Be A Open screw covers B Remove Back Panel and screws Location of screws for option B fastening Synel Industries Ltd 3 Installation PRX 40 A 2 3 Connect wires Connector J5 14 pin Wire No Wire Function Present Color Code 1 Vin Power Power Input Red 2 Gnd Black 3 TxRx RS 485 Grey 4 TxRx RS 485 Purple 3 TxD RS 232 White 6 RxD RS 232 Dark Green 7 Alarm Brown 8 Relay common C Blue 9 Normally Closed N C Yellow 10 Normally Open N O Orange 11 Bell 1 Pink 12 Bell 2 Light green 13 Sensor input Dry contact Light Blue 14 or AC DC Sensing regard Brown White jumper JP23 settings Connector J4 9 pin ISP Co
16. ltaneously mandatory press Enter in termi nals that consist of an Enter key in order to revert to normal mode Using Card Build list After entering set up mode key in code 20 Insert card to list by card and swipe all relevant cards After each swiped card 2 short beeps will indicate that the number was registered successfully After swiping all cards press 7 amp 8 simultaneously mandatory press Enter in terminals that consist of an Enter key in order to revert to normal mode Note In set up code 12 operation mode no 4 card and pin code the user must swipe the card and then key in the code a 4 digit code Delete list After entering set up mode key in code 21 delete card by card and swipe all irrelevant cards After each swiped card 2 short beeps will indicate that the number was deleted successfully After swiping all cards press 7 amp 8 simulta neously mandatory press Enter in terminals that consist of an Enter key in order to revert to normal mode Note Whenever a task is completed successfully a LED flashes and the buzzer beeps By index Insert cards Synel Industries Ltd 11 Set up mode PRX 40 A After entering set up mode key in code 24 Insert card by Index and key in a 4 digit index swipe card 2 short beeps will indicate that the number was registered successfully After swiping all cards press 7 amp 8 simultaneously mandatory press Enter in terminals that consist of an Enter key in
17. nnector J12 6 pin Connector J13 14 pin Keyboard connector programming the CPU slave Option for external reader Synel Industries Ltd PRX 40 A Installation How to connect the PRX40A to the Master controller MASTER CONTROL UNIT RJ 11 TO RJ 11 6 WIRES CROSSBARD FLAT CABLE ge 772046 PURPLE WIRE OF PRX40A GRAY WIRE OF PRX40A TxRx of RS 485 E TxRx of RS 485 CONNECTION BOX FOR RS 485 COMMUNICATION CAT 460250 Synel Industries Ltd 5 Installation PRX 40 A 2 4 Jumpers Jumper Function Default JP2 SMD JP2 closed and JP3 open Linear decoding Linear JP3 SMD JP2 open and JP3 closed Synel decoding JP4 SMD _ Cross point decoding currently NA JP7 SMD Connect RS 485 termination resistor Open JP10 TH W D Reset for the master CPU 1 2 Closed 1 2 closed Programming of the master CPU 2 3 Closed JP11 TH PSEN Programming must be closed when pro Open gramming the master CPU JP12 SMD Tamper switch enabled 1 2 closed 2 3 closed Tamper switch disabled 2 3 closed JP20 T H Closed Stand alone Closed Open Online with Master JP21 T H Contacts switching protection in DC closed Closed Contacts switching protection in AC open JP22 SMD Connecting clock to slave CPU 2 3 closed JP23 T H Select sensor option 1 2 and 3 4 1 2 and 3 4 Closed dry contact clos
18. rint unit polls all existing templates until there is a match and confirms rejects e PRintX40AV Verification requires a card code The template is stored in reference to a card code Upto 1000 card codes and templates are stored When an employee swipes his card keys in his code the unit checks if the card code number exists if it does it checks also the tem plate assigned to that number 2 Technical Specifications e Maximum Range 10 cm 4 inches e Operating Frequency 125 kHz e RS 2320r RS 485 ASCII 9600 b s e Storage for 1000 200 templates e False rejection rate 0 01 e False acceptance rate 0 01 Synel Industries Ltd 17 Appendix A Fingerprint Unit PRX40A 2 1 Indicators A led is activated to indicate current status as follows A flashing orange led indicates that the employee is requested to Flashing orange place his finger for sampling purposes while Enrolment process is on Orange Waiting for fingerprint validation while performing verification Green Successful operation Red Operation failed 2 2 Man machine Interface e Indicator for Power card confirmation rejection and keyboard entry fin gerprint a tri color led e 10 digit keyboard e Bell button e RF coupling of proximity card e Buzzer for audio confirmation of operations 2 3 Mechanical Features e Dimensions 137X115X28 mm e Weight 360gr e Operating temperature 0 to 60 C 2 4 Electrical
19. s when installing the communications cables The cable should not be installed near EMI factors such as e Motors generators alternators and transformers e Air conditioners elevators e Radio television transmitters signal generators and internal communica tion networks e Cables within 30 cm 1 foot of power lines of less than 5 KVA e Cables should not be within 60 cm 2 feet of power lines in the 5 10 KVA range Cables should not be within 1 5 meters 5 feet of power lines of more than 10 KVA The cables should not run parallel to power lines for more than 15 meters 49 feet It is best to use a single cable for the communication line If it is not possible to use a continues cable only one indoors connection is allowed constructed in one of these options 1 Using two connectors with appropriate shielding and cover Zi Using a connection box For aerial installation use N Y Y shielded cables Synel Industries Ltd 15 Communication PRX 40 A 4 2 Technical Specifications 4 2 1 Man machine Interface Indicators for power Indicators for card presence rejection Keyboard entry 10 digit keyboard Bell button Buzzer for confirmation of operations 4 2 2 Mechanical features Dimensions 13 x 4 3 x 2 cm Weight 180g Operating temperature 22 to 50_C Relative humidity 95 4 2 3 Electrical characteristics Output relay rating 24Vdc 2 A Alarm sensor output TTL level mx 16 mA Alarm set