VERID Datasheet (Issue 2)
Contents
1. For LED control PSS 2 Jatt to enteral device 5 d Ps if e TCC TTTTCTTCCCTCSY P65 __ Resened Sd 28 o 8p asaas a E put rom PIN Data or Wiegand 1 P26 rnp trom PIN CarcPresent dY 3p ovorKeypag a put tromPn timeout d 12 eypad coun i CCC Verid is designed so as to comply with UL294 Verid complies with the following EMC requirements Il Specifications Maintenance Verid is essentially maintenance free but will benefit from periodic cleaning of the optics and housing Clean the finger platen with a soft linen free cloth The housing Case Details Europe Height 160mm EN55022 Emissions class A Width 165mm may be cleaned with a soft cloth and non Depth 65mm EN50082 1 Immunity class A abrasive liquid detergent Weight lk Warning this is a Class A product In a domestic gnt g environment this product may cause radio interference in which case the user may be required to take adequate measures Temperature 5 North America TSSI Operation 0 C to 40 C Ei Rutland House Storage 10 C to 50 C FCC rules CFR47 part 15 limit A Hargreaves Road Humidity range 40 C Groundwell Industrial Estate 10 to 80 non condensing Verid has been tested and found to comply with the limits for a Class A digital device pursuant to part Swindon 15 of the FCC rules These limits are designed to Wiltshire SN2 5AZ provide reasonable protection against harmful U K inte
2. RS232 or RS485 and storage of templates on track 3 of a standard magnetic card mM RS485 Network template transfer Once installed the dedicated 485 network will automatically transfer information on newly enrolled deleted or updated templates Adding new units into the network is also made easy with all new units automatically adopting the configuration of the other units on the network The network architecture is a linear twisted pair terminated with 120 ohm resistors with no spurs HM Template on track 3 of mag card The fingerprint template can be stored on track 3 of a magnetic card rather than in the Verid unit itself Verid must be configured to accept template entry by this method and the card used must also contain PIN data on track 2 Configuration is possible via the RS232 port using Verid Manager The 3 5mm jack connector on the underside of the unit provides RS232 communications Verid Manager from TSSI offers a variety of template management options including capturing or writing the complete database capturing or writing individual records and storing records in a PC for backup or transfer to other units More details are available in the document Verid Manager User Guide HM RS232 Communication Protocol Characters are sent at 19 200 baud Handshaking is not provided and the character format is Start Bits 1 Data Bits 8 Parity Bits None Stop Bits 1 M Message Format Communication bet
3. enable selection of the appropriate function during the enrollment process The LCD display can be programmed via the RS232 port using Verid Manager to display alternative languages including languages requiring double byte character sets When the unit is powered up the LEDs will initially cycle through a sequence to determine the network and configuration status This is described in detail in the Verid User Manual Once completed some of the LEDs may stay illuminated to indicate network status The LEDs will be cleared once the first PIN is received Number of users Each Verid unit can store templates on up to 5000 users Each of the 5000 users can have either one or two fingers registered Security Levels Verid Each Verid unit can be set into one of 7 security levels Levels 1 to 5 strictest check the fingerprint to differing degrees of accuracy Additionally Verid can be set to PIN only i e no fingerprint checking and Any fingerprint i e the user places a finger on the unit which is then apparently checked but will always pass Security Levels Users During the enrollment of each user and SuperUser a security level can be assigned to that user The levels that can be assigned to that user are Global setting The user will adopt the security setting of the Verid unit Levels 1 to 5 strictest check the fingerprint to differing degrees of accura
4. BIOMETRIC Verid Fingerprint Reader TSSI s Verid fingerprint reader provides access control systems with instant improved security VERIFICATION Installed between the existing PIN entry device and the door controller Verid confirms the presence of the correct person No changes are needed to the cards PIN entry devices or access control system software The complete verification process and database are all held within the single wall mounted housing which contains fixing terminals for the data cables Two versions of the reader are available a verification only unit and an enrollment unit Verification Unit Uses LED s only to guide the user through the verification process Mode of Operation The Verid verification unit accepts a PIN from a PIN entry device A comparison is then made between the template from the live finger and the original template associated with the PIN Templates can be stored in Verid or on track 3 of a magnetic card If the templates match Verid outputs the PIN data PINs and templates are loaded via the integral RS232 or RS485 ports Enrollment Unit Configuration fj PIN Input Devices In addition to the LEDs enrollment units have an integral LCD display and control keys These units enable new users to be enrolled onto the system m Modeof operation The enrollment unit performs all the functions of the verification unit with the added capability of enrolling upd
5. ating and deleting users from its intemal database This information can then be extracted via the RS232 port and transferred to other Verid verification or enrollment units Automatic transfer of templates is available via the integral RS485 network connection Verid is supplied in a standard configuration with Input Magtek track 2 timing Output Magtek track 2 timing LED control Internal Database Intemal CardPresent Not set TimeOut Not set These settings can be altered by sending commands via the RS232 port The detailed command set is contained in the full Verid manual Alternatively the configuration can be set using the Verid Manager PC software kit available from TSSI Requires a PC running Windows 95 or later All PIN input devices are connected to Verid through the terminal block on the inside of the back panel Verid supports a wide range of standard inputs m SO Track 2 Magtek or Omron timing Requires Strobe and Data signals Option of TimeOut and CardPresent ISO Track 2 PIN Format Data must conform to ISO7811 track 2 format Max PIN length is 16 characters excluding start end sentinels If more than 16 characters are sent Verid will truncate it and use the first 16 characters as the PIN m Watermark Magnetics Requires Strobe and Data signals Option of TimeOut and CardPresent Watermark PIN Format Supports all registered LRC or non LRC Watermark formats m Wiegan
6. cy Any fingerprint and PIN Input Only can also be assigned to the user A user s individual security level will override the global level set on the Verid unit being used If a network of Verid units is set up the following tasks will take place automatically normally without any PC or user intervention e Any users added deleted or updated will immediately be broadcast to all other Verid units on the network e Any new units added to the network will adopt the configuration e g PIN device and messages of the other units on the network e Network address information will be resolved by the Verid units on the network to avoid duplicate network IDs Installation Fixing Details Attach the backplate to the wall using the four fixing holes provided see diagram Note a gap of 3mm must be left between the fixing plate and any adjacent object to accommodate the housing Connect all system wiring to the screw terminals before RL diam 5mm 8 6 153 6 b A 162 1 All dimensions in mm connecting the ribbon cable from the Verid unit to the terminal plate Insert the top of the housing over the back plate and fasten using the two bolts on the base of the unit For maximum security we recommend the use of anti tamper bolts size M4 metric Installation All connections are made via the interface PCB mounted on the rear plate Terminal No o Teminainof S a a GS OV
7. d Requires Wiegand 0 and Wiegand 1 signals Option of TimeOut and CardPresent if available Weigand PIN Format Card data must conform to either a Wiegand 2601 standard or b General Weigand i e from a reader which always outputs the data in the same direction M PIN Keypad up to 4x4 Each key must have a row and column location assigned to it PIN Format PIN lengths can be set between 1 and 16 digits The factory default is 4 Input Terminal Connections Ls 5 0V terminal Strobe 24 4 3V Data 25 CardPresent 26 _ 0 0V TimeOut 27 J Data Output Error Codes Output fl RS232 Interface If the finger fails to match the template the PIN data output is PIN device Error Code After a successful template match the PIN data only is sent from Verid With the exception of a PIN pad the data is output in the same format as it is received from the PIN entry device PIN pad data is output in ISO track 2 format with either Magtek or Omron timing Output Terminal Connections Strobe terminal 31 Data terminal 32 CardPresent terminal 33 TimeOut terminal 34 Weigand 2601 26 bit data 000000 ISO Track 2 ISO card with data 000000 General 26 bit data 000000 Weigand Watermark Registered Watermark card data 000000 Template Management Verid supports three methods for managing templates transfer via
8. rference when the equipment is used in a Telephone 44 1793 747700 Power Requirements commercial environment This equipment generates Facsimile 44 1793 747701 uses and can radiate radio frequency energy and if i z mail Verid tssi co uk 10V to 14V not installed and used in accordance with the S b erid a3 ra 500mA max instruction manual may cause harmful interference wen www tssi co u Verid is a trademark of TSSI to radio communications Operation of this equipment in a residential area is likely to cause In order to meet the requirements of EN60950 Verid should be powered from an SELV supply harmful interference in which case the user will be required to correct the interference at his own expense Reference vfu 02 A Scipher Company
9. ween the reader and PC uses the following frame format in both directions Header Length Identifier Data CRC e Header a sequence of four bytes indicating the start of a message They are 76 9A 4D and C6 hex e Length two bytes which define the number of bytes following the length field e Identifier a single byte which indicates the type of message e Data a data field where required and can be of variable length dependent on the message being sent e CRC two bytes covering the Identifier and Data fields User Interface Power up LED show Network functions All Verid units have six LEDs to indicate the status of the unit and guide the individual through the verification process see diagram In the standard configuration all the LEDs are controlled by the Verid unit but an option is available for the tristate Go NoGo LED to be controlled by the host system The external system controls the LED with two lines which are driven by 5V logic levels 5 0V High 2V 5V Low OV 1 6V Inputs are high impedance with 100kQ pull up resistors LED control connections OV terminal 1 line 1 terminal 2 line 2 terminal 3 cmi Place finger press harder How Hold finger in position Decetase Remove finger Busy Processing data Gojnoc f Green match OK Flash red match failed READY Power on Enrollment units also have an LCD display and four keys to
Download Pdf Manuals
Related Search
Related Contents
User`s Manual MANUAL DE USO E MANUTENÇÃO PALIO 454 Sequencing System Software Manual, v 2.5p1 General Regenwassernutzungsanlagen Aquarius Rain Water Utilisation Minox DC 6033 WP User Guide Samsung DVD-V8500 User's Manual Telescopic Flagpoles Installation Manual Banner - flag 2010 2011 DIVING GAUGES 2010-2011 DIVING GAUGES MEGA MANUAL INSTRUCCIONES CAMPANAS BUILT Copyright © All rights reserved.