Portable Dataloggers User Manual rev.2_EN

image

Contents

1. E no 1 epa ABC2abc DEF3def E GHI4ghi JKL5jkl 6 MNO6mno PORS7pqrs E TUVStuyv E WXYZ9wx yz O 0 _ space iPage Portable Dataloggers User Manual BUTTONS Buttons are used to select an action which frequently means navigating to a new screen Just move focus to the desired button and click the ENTER key 2 ft Manualread 2 Batch read Generally no BACK or ABORT button is on the screen to return to the previous screen or abort the current operation just press the ESC key on the keyboard As an alternative most buttons contain a number at the left of their labels just click the matching number to trigger the button action When no button is selected the ENTER key is normally used to confirm the most obvious operation for example when a list is selected clicking the ENTER key will usually bring you to the next screen with the currently selected item LISTS D232TXXX al D313FVXX ELI420MA L2CTOXXX S412HV 10 REX451XX TMPTIO Lists are used to select one of several items when a list is selected you may change the selection clicking the UP or DOWN keys The LEFT key will move to the beginning of the list and the RIGHT key will move to the end By clicking ENTER the current item is selected Only in configuration windows when a list box is displaying items defined by the user for example sites or instruments it is usually possible to delete t
2. 0 HRO_ _ 22 KK S1 P4 D232T002 a S1 P 2 D232T003 S 2 P 1 420MAGEN22 v II ec Scan Clear Browse The instrument is marked as read and the next instrument in the list is selected move the Switch to the new position then press ENTER to proceed reading it READING WORKLISTS When reading a Worklist the DL first displays a list of all instruments in the selected Worklist WORK D232T002 A D232T003 ELI420MA Es LA A Scan Clear Browse Rev 2 31 01 2013 IPage Ah Ni y Portable Dataloggers User Manual S ISGEO Select the instrument you wish to read and press ENTER the DL will display the cable wiring for the selected instruments Instrument cabling WM 4 20mA 2 wire single Take all the precaution as for read a normal instrument Check carefully the instrument type and connections a mismatch may cause damage to the connected instruments or the DL Press ESC to return to the previous screen or ENTER to proceed reading the selected instrument Reading instrument ENO D232T002 mA You may record the currently read value by pressing ENTER key You may return to the list of instruments in the Worklist by pressing the ESC Rev 2 31 01 2013 DiPage Portable Dataloggers User Manual USING THE USB INTERFACE The DL features an mini USB interface connector for connecting to a PC This same connector is used for an external push button used for inclinomete
3. 01 2013 IPage Portable Dataloggers User Manual The maximum number of digital inclinometers that can be read from the DL at the same time option energy saving not enabled is 20 stick to this number to avoid damages to the DL and or to the digital inclinometers The theoretical maximum number of digital inclinometers that can be read from the DL sequentially option energy saving enabled is 254 addresses RS485 from 1 to 254 EDITING SWITCH PANELS CHANNELS After creating a new Switch Panel press ENTER after selecting a Switch Panel in the list of Switch Panels for the current site the display will show the channel assignment for the current Switch Panel Edit switch panel EN When first created switch panels are empty click the Add button to add an instrument the DL will display a page for selecting the instrument to add Select instrument D2321002 as 420MAGEN2W D232T003 420MAGEN22 ELI420MA Select instrument and press ENTER the DL will display a page for selecting the Selector and the Position on the Selector for the new instrument Rev 2 31 01 2013 MM Page A NN Y Portable Dataloggers User Manual S ISGEO Select position E vy Name D232T002 Selector 1 Y Position ho Notes Enter Selector and Position and eventually fill the Notes field then press ENTER Edit switch panel AT 1 P1 D232T002 da Add The instrument will b
4. 3 111 30 06 10 13 21 4 222 30 06 10 13 22 6 922 30 06 10 13 22 9 706 30 06 10 13 22 13 165 30 06 10 13 22 15 020 You may delete the currently selected reading by pressing the DEL key Deleted readings will not disappear immediately they will just be hilighted in red you may undelete a reading by pressing the DEL key again After exiting this window readings marked for deletion will actually be purged When you have finished press the ESC key Rev 2 31 01 2013 y Page DP ag v O Portable Dataloggers User Manual SISGEO ve ene READING STANDARD INSTRUMENTS SINGLE It is possible to read instruments without configuring them by using Standard Instruments in this case instruments are read without using any calibration parameters so such readings may be used to test that a given instrument is functional or to read the instrument in electrical units It is not possible to record readings performed with Standard Instruments MIST OM Standard 2 To perform such readings select Manual read from the Main menu then click the Standard button The DL will display a screen for selecting the family of instrument to measure New instrument E lStandard O Wire O Biaxial ETICA 420MAGEN3W D232TXXX D241A200 D313FAXX First select the family of instruments Standard Dual or VW by NEXT scroll and PREVIOUS scroll keys and press ENTER then select the specific instrument type and
5. O V A SISGEO Portable Dataloggers User Manual SISGEO READING INSTRUMENTS SINGLE To read single instruments select Manual read from the Main menu The DL will display a list of sites you may either select a site and press the ENTER key or click the Standard button at the bottom of the display Select site E MYSITE a Standard If you click Standard you will be able to select a predefined instrument not configured from the user refer to Reading standard instruments for details When selecting a site you will see a list of the instruments previously configured from the user defined in the current site Select instrument D2327002 420MAGEN2W D232T003 420MAGEN22 ELI420MA gt Browse Select and instrument and press ENTER to proceed reading it by clicking Browse instead you will be able to view an history of measures performed on the instrument in the past Rev 2 31 01 2013 Mj Pace A y NN y Portable Dataloggers User Manual S ISGEO Instrument cabling C 4 20mA 2 wire single The DL will display a description of the connection cables for the selected instruments Connect the flying cable 1MIL connector and alligator clips to the DL Never force a connector into the port Check for possible obstructions in the port If the connector and port do not connect easily they probably do not match Make sure the connector matches the port Connect the inst
6. Deformation System 24V 20mA mA 3 red black shield SCLIN45X Tilli portable tiltmeter 12V 5000mV mV 0 red white black yellow green shield T111PT10 Thermometer Pt100 1mA 10000 do 1 red white black green shield T3800GKA Built in thermistor NTC 0 1mA 100000 C 1 white green shield iPage Portable Dataloggers User Manual NOTE The unit is two channels datalogger To make the measurement of DEX35SXX 3D borehole sensor three channels you have select DEX in place inclinometer DEX35XXX for inclinometer bi axial instrument and then you have to select the DEX in place extensometer DEX35XXX to make the extensometer mono axial instrument NOTE To take the measurement of OD3FISOXX you must to connect pin B with pin F Rev 2 31 01 2013 IPage Portable Dataloggers User Manual VIBRATING WIRE INSTRUMENTS O O E O RC EC A EC RC EI EA O D232TXVW Vibrating Wire Embankment extensometer Digit black white green shield D313FOXX Vibrating Wire deformometer Digit red black white green shield D313SXXX Vibrating Wire crackmeter Digit red black white green shield D314CXXX V W embedmaent jointmeter Digit red black white green shield D422RXXVW V W DSM embank Digit red black white green shield DTEXXXVW V W Linear transducer Digit red black white green shield L143DXXX Vibrating wire pressure cell 230mm Digit red black white green shield PK45AXXX Vibrating wire piezometer Digit red black white green shield PK45CXXX Removible vibrating wire p
7. Manual These data include Name Notes Code Unit Warm up Decimals The name used to identify the instrument this is initially set the same as the instrument code but should be changed from the user before saving the instrument User notes related to the instrument The instrument model this field cannot be edited by the user The unit of measure label the user may either select it from the drop down list or edit a new unit of measure editable only for analog instruments The warm up time recommended for the instrument in seconds this is used by the DL when reading instruments connected through a Multiplexer editable only for analog instruments The number of digits after the decimal separator used when displaying readings for example 3 means that the number will be formatted as 20 000 Instrument identification OCO Name 420MAGEN2W Notes Code 420MAGEN2W Unit mA U Warmup O Decimals 3 After editing data in this screen press ENTER key the DL will display the cabling screen instrument s wire colors Rev 2 31 01 2013 Instrument cabling 4 20mA 2 wire single j gt Ze gt DARCRN UE UN D O O gt o Q gt lt O O lt Nn Prime color list iPage pe y Mi y Y Portable Dataloggers User Manual SISGEO The colors for each wire are preset for the instrument category you have s
8. and or recalibrations should always be carried out at SISGEO factory or by personnel trained and authorized by SISGEO In case of repair and or recalibration please send us the device and every accessory in the container provided in order to prevent damage from shocks during transport This procedure involves the filling out of the form on our website www sisgeo com to the link assistance repairs once inserted the request a confirmation with the related authorization code will be sent to the e mail address indicated The material has to be packed properly and sent in door to door basis freight to client charge to SISGEO S r l Via F Serpero 4 F1 20060 MASATE MI Attn to Technical Assistance Office Tel 39 02 95764130 Fax 39 02 95762011 e mail assistance sisgeo com PHONE ASSISTANCE Telephone support for installation configuration of equipment measurement systems and Software TECHNICAL ASSISTANCE ON SITE FOR THE SUPPLIED INSTRUMENTATIONS Technical support for the installation of monitoring systems with its commissioning and start up through the add of specialized technician s teams TRAINING Possibility of training at our Factory or at site related to the installation procedures the system configuration and the use of measurement systems Rev 2 31 01 2013 IPage Portable Dataloggers User Manual APPENDIX A STANDARD DIGITAL MONO INSTRUMENTS E O EA E O E EEE Poo foe E E 24V mA 3 Rev 2
9. can send the file as an email attachment SYMBIAN S60 3 EDITION There are some precautions to take with this Operative System OS symbian OS e The user should use an application File Manager that allows to save the file SGX because the OS tries to interpret the content and does not allow saving the file The file manager is available for free in Internet SISGEO suggest a free application called Active File ver 1 44 e After receiving the message BlueTooth you have to open the File Manager through it you have to copy and paste the file in the desired folder e By creating a new mail you can attach the file saved as generic RIM ver 5 0 0 822 E e e e TPL There are some precautions to take with this Operative System OS FT 22 BlackBerry e To receive the file is necessary to entry in the Multimedia folder and thought the menu button you should select Receive using Bluetooth item The smartphone will be available to receive file Now you can send the file from the datalogger Rev 2 31 01 2013 M lPage Portable Dataloggers User Manual WINDOWS MOBILE ver 5 amp 6 Windows Mobile There are no special precautions to take with this Operative System OS The file are managed as under Microsoft Windows for PC Rev 2 31 01 2013 IPage v Ar O X SISGEO Portable Dataloggers User Manual UTILITIES The utilities menu features commands to s
10. from the user In this case will be displayed the reading Only readings in configured unit first page can be stored in DL memory Calibration values for the thermistor used with the wire should not be changed by user If the gauge value inserted is zero the screen with the unit of measure in uE will be displayed anyway but the reading will result zero While editing the instruments parameters you can return to the previous page pressing the ESC key If you press ESC key on the first page you will return to the instruments list without saving your changes For vibrating wires instruments different values can be displayed during the measure e Hz Hertz the measured frequency of the oscillation e s micro seconds the period of the oscillation e peo uEpsilon micro Epsilon calculated as Epsilon gauge x digit e Digit calculated as z2 e iit 7000 e User units are calculated using the polynomial entered by the user Rev 2 31 01 2013 IPage Portable Dataloggers User Manual CONFIGURING MULTIPLEXER STANDARD CHAINS OF DIGITAL INCLINOMETER SWITCH PANEL and WORKLISTS Before configuring Multiplexers Switch Panels and Work lists from now we call these items Selectors when the differences are not relevant you must define the instruments that you wish to read through these Selectors in the same site in which you wish to add a new Selector The single SISGEO S digital inclinometers from a digital inc
11. is the measured inside the DL at the AD converter chip so it will normally be a little higher than the room temperature CHANGING USER INTERFACE LANGUAGE Click the Set language button in the Utilities menu to change the language used by the DL The DL will display a list of available languages select your language and press ENTER Set language AT Italian The DL will revert to the previous screen with the newly selected language Rev 2 31 01 2013 MlPage ah vy Ne Y Portable Dataloggers User Manual S ISGEO 1 Imposta data e ora 2 Stato unit 3 Imposta lingua If you find a DL set in language that you cannot understand from any screen of the user interface press ESC for a few seconds till the DL reverts to the main menu then press the 5 button followed by the 3 button then select your language Rev 2 31 01 2013 IPage Portable Dataloggers User Manual TROUBLESHOOTING DL does not switch on The battery is not correctly recharged Battery recharger LED does not perform the foreseen colorur sequence as in DL manual DL display has no back light DL crashes DL reads incoherent values DL showed Check connections before continuing DL does not update firmware It hasn t been done the correct startup keys combination A connector from the DL internal battery disconnected Battery s temperature overcomes 70 C internal security system stops the power circuit Repeat the st
12. proceed as for a normal instrument The reading procedure for the standard single digital instruments is equivalent to the standard single instruments For the warnings dialog box refer to paragraph READING SINGLE DIGITAL INSTRUMENTS Rev 2 31 01 2013 e Page E i P a g A Y XA O vk r Portable Dataloggers User Manual SISGEO READING MULTIPLEXERS SWITCH PANELS AND WORKLISTS For reading instruments connected through Multiplexers Switch Panels and Work lists from now we call these items Selectors when the differences are not relevant select Batch Read in the main menu Batch measure 2 Switch panel 3 Work List Then click the button matching the kind of Selector you wish to use The DL will ask the site in which the Selector is to be found Select site MA S IIS A wv Select the site and click ENTER to view a list of Selectors of the chosen type Select multiplexer E MUX16x2 a ABC Rev 2 31 01 2013 Page vtd Y gt SISGEO Portable Dataloggers User Manual SISGEO Choose your Selector and click ENTER the way to proceed from now on is quite similar for all the types of selectors with some minor differences due to the peculiarities of each Each of them displays a list of connected instruments the DL keeps track of the last value read for each instrument connected to a Selector this value is shown in a gray bar at the bottom of the list when an
13. to retrieve the settings of the digital inclinometers Typically the chain s instrument are identified consequentially starting from number one to the instrument s total number this last number has to be inserted in the field Addr max Address RS485 maximum To reduce the DL s current consumption inclinometer s chains can be configured in order to switch on the inclinometers in different times this function is managed through two parameters warm up and delay If the inclinometer chain has been enabled the energy saving check the option Energy Saving and fill in the field warm up and delay according to the inclinometer s chain parameters After editing address 485 max in the inclinometer s chains to check the option Energy saving just press the key Next scroll and then press the key will be automatically enabled the fields Warm up s and Delay s When the option energy saving is enabled every inclinometer from the chain will switch on after a different delay according to its address during the reading the datalogger will wait the suitable time before to read an instrument and move to the next one Every inclinometer will turn off after the reading Waiting time RS485 address delay warm up When the option energy saving is NOT enabled every inclinometer of the chain will be powered and switched on at the same time The inclinometers will switch off after the reading
14. 31 01 2013 420MAGEN2W Generic 4 20mA 2 wires 20mA shield 420MAGEN3W Generic 4 20mA 3 4 wires 24V 20mA mA 3 shield D232TXXX Embankment extensiometer 24V 20mA mA 3 red black shield D241A200 Wire Crackmeter Deformometer 24V 20mA mA 3 red black shield D313FAXX Electrical Crackmeter Jointmeters 24V 20mA mA 3 red black shield D313FVXX Electrical Deformeter 24V 2000mV mV 1 red black white green shield D313MAXXX Electrical Deformeter 24V 20mA mA 3 red black shield D313MVXXX Electrical Deformeter 24V 2000mV mV 1 red black white green shield D313SAXX Electrical Crackmeter 24V 20mA mA 3 red black shield D313SVXX Electrical Crackmeter 24V 2000mV mV 1 red black white green shield D314CAXX Embedment joinmeter 24V 20mA mA 3 red black shield D3FISOXX CRID sensor 2 5V 2500mV mV 1 red black white black shield D422XXXX DSM gauge 24V 20mA mA 3 red black shield DEX35SXXX In place extensometer 24V 10000mV mV 0 brown grey yellow pink shield DEX35XXX In place extensometer 24V 10000mV mV 0 red black white green shield DTE1AXXX Displacement transducer 24V 20mA mA 3 red black shield DTE1VXXX Displacement transducer 24V 2000mV mV 1 red black white green shield DTMOAEXX DTM displacement transducer 1000mm 24V 20mA mA 3 red black shield L141XXXX Earth pressure cell 100x200mm 24V 20mA mA 3 red black shield L2CEOXXX Stell lining pressure cell 24V 20mA mA 3 red black shield L2CTOXXX Electrical load cell 2 5V 2 0mV V mV V 3 red black blue green yellow white shield L2XXVXXX Elect
15. CAL DATASHEET New Leonardo Leonardo Archimede Galileo Technical Specifications m mV V mV V C Hz US digit C pE n 2 24bit A D converter with A D converter autocalibration 19 true bit 4 20mA 10mV 400mV 5V Measuring range 10000 Pt100 100000 NTC from 400 to 6000Hz 1114 with F S 20mA 1pV with F S 10mV 10pV with F S 400mV 100uV with F S 5V 0 1 C with F S 10000 Pt100 0 1 C with F S 100000 NTC 0 1 Hz with FS from 400 to 6000Hz 0 001mV V with FS 10mV V Accuracy 0 01 F S Type of measurement Hz us digit C pe 100000 NTC from 400 to 6000Hz Measuring resolution 0 1 Hz with F S from 400 to 6000Hz Temperature drift 0 001 F S C gt 10MO for voltage lt 2 5V mput impedance gt IMO for voltage gt 2 5V Storage memory 2GB Rev 2 31 01 2013 IPage A y Portable Dataloggers User Manual SISGEO Operating time Battery charger Display Rev 2 31 01 2013 Mi Page 4 Portable Dataloggers User Manual SISGEO 3 led New Leonardo Leonardo Archimede Galileo Rev 2 31 01 2013 IPage vi Portable Dataloggers User Manual SISGEO Dd New Leonardo Leonardo Archimede Galileo Weight Lx Wx H Rev 2 31 01 2013 IPage
16. EADING MULTIPLEXERS SWITCH PANEL and WORKLISTS Pag 54 READING MULTIPLEXER STANDARD Pag 55 READING SISGEO S DIGITALINCLINOMETERS CHAINS Pag 57 READING SWITCH PANNELS Pag 58 READING WORKLISTS Pag 59 USING THE USB INTERFACE Pag 61 USE WITH SMART EXPORT and SMART MANAGER Pag 61 USE WITH SMART DATACAL Pag 62 USE WITH SMART REMOTE Pag 62 USING THE BLUETOOTH INTERFACE Pag 64 Android 2 2 Froyo Pag 66 Symbian S60 3 Edition Pag 66 RIM ver 5 0 0 822 Pag 66 Windows Mobile ver 5 amp 6 Pag 67 UTILITIES Pag 68 SETTING DATE and TIME Pag 68 CHECKING DL STATUS Pag 69 CHECKING USER INTERFACE LANGUAGE Pag 69 TROUBLE SHOOTING Pag 71 ASSISTANCE Pag 72 Repairs and maintenances Pag 72 Phone assistance Pag 72 Technical assistance on site for the supplied instrumentations Pag 72 Training Pag 72 APPENDIX A Pag 73 Standard Digital mono instruments Pag 73 Vibrating wire instruments Pag 5 Bi Axial instruments Pag 75 Probes Digital probes Pag 76 SPECIAL KEYBOARD COMBINATIONS Pag 77 Switch ON Pag 77 Switch OFF Pag 77 Alternate display modes Pag 77 Emergency reset Pag 77 Firmware upgrade Pag 78 EARLIER FIRMWARE VERSION Pag 78 TECHNICAL DATASHEET Pag 79 Rev 2 31 01 2013 IPage Portable Dataloggers User Manual NOTE ON SYSTEM UTILIZATION To ensure a safe and efficient functioning please read the following instructions carefully before use Any unauthorized modification is considered a total responsibility of the user In ad
17. ame Enter the name for the new Switch Panel or Worklist and press ENTER In the case of Multiplexers it will also ask some information about the kind of Multiplexer that will be used the number of channels and the number of wires per channel Name Mux 32 2 wires OMux 16 2 wires OMux 32 4 wires OMux 16 4 wire Configuration type of the Number of physical Igital MES Multiplexer board channels of the es 4 20mA current loop 2 Multiplexer board wires PT100 platinum RTD 4 wires Once inserted Multiplexer s name move on the flag button that match the type of the Multiplexer using the keys NEXT Scroll or PREVIOUS Scroll and push ENTER Please be careful especially when choosing between 2 and 4 wires models as the multiplexing sequences are not compatible and the DL will be unable to perform any valid reading on an incorrectly configured Multiplexer Rev 2 31 01 2013 IPage Portable Dataloggers User Manual In case of doubts you can verify the DIP switch panel position on the multiplexer Board only the switch 1 and 2 are relevant the position of the dip switch from 3 to 8 can change 2 wires Multiplexer 4 wires Multiplexer ARANA SOS Se Se a r E H T 7 TE E eE ale a gt i it n F HM E El bl uy EN u If p o T A sale ie a oe a A SE MUX16 2 wires MUX16 4 wires MUX32 2 wires MUX32 4 wires Choose digital Inclinometers when you wan
18. anagement button the DL will display the initial splash screen On the PC run the SmartRemote program When it starts click the Connect button at the top of the displayed window on the PC 2 Batch read 3 Configuration 4 Communication 5 Utility Rev 2 31 01 2013 The refresh button at the top may be used in case the display fails to update Software s virtual keys in the lower part of the window have the same function of the real ones on DL keyboard they can be pushed with the left mouse button To press more keys at once for example to obtain the effects described in the Special keyboard combination chapter you may lock a key by clicking on it with the right mouse button Right click it MlPage Pag Portable Dataloggers User Manual again to unlock it All the time the physical keyboard on the DL is fully functional so you may find more comfortable to use it instead of the simulated keyboard on the PC You will notice that when using SmartRemote the DL is slightly slower than usual this is normal and it is due to the fact that the screen must be transmitted to the PC when it changes The DL is fully functional when being used with SmartRemote except that the USB Disk and USB Calibration functions in the Communication menu are disabled Communication EU 1 USB Disk 2 USB Calibration 3 Bluetooth 5 Remote management off Also when read
19. andard Multiplexer Check carefully that the parameters used from DL to read digital inclinometers match the ones of the inclinometers chain For the warnings dialog box refer to paragraph READING THE DIGITAL INSTRUMENTS SINGLE Rev 2 31 01 2013 IPage NN O V gt SISGEO Portable Dataloggers User Manual SISGEO READING SWITCH PANELS When reading a Switch Panel the DL first displays a list of all instruments connected to the selected Switch Panel SWITCH PT S1 P 1 D232T002 A S1 P 2 D232T003 S 2 P 1 420MAGEN22 v Scan Clear Browse Connect the flying cable QECAVO7V200 to the DL and to the Switch Panel i Check carefully that the selected switch panel matches the one physically connected to the DL a mismatch may cause damage to the connected instruments or to DL Choose the instrument you wish to read and place the Selector to the required Position as shown at the left of each instrument then press ENTER Rev 2 31 01 2013 IPage Portable Dataloggers User Manual Reading instrument ECO S1 Pi D2327002 mA The DL will start reading the selected instrument displaying the value read Press ENTER to record the value the DL will revert to the list of instruments SWITCH _ oo _ _ __ __ _____ _ o _ _ __ _ __ __ _ o _ _ _ _ _ _ a
20. artup procedure see paragraph Special combination keys in the reference DL manual Connect the battery charger and try to turn the DL on If the DL turns on contact SISGEO s assistance Wait at least 30 minutes to allow the battery to become colder and go back in the appropriate temperature range Check DL battery level available in menu Utilities gt Unit Status directly on DL The battery charger could have not correctly detected the battery Battery s temperature overcomes 70 C internal security system stops the power circuit Display backlight could be turned off or set on minimum value DL software generates an unexpected error Sensor s connections are wrong A D converter does not understand signals correctly Instrument is connected to DL in a wrong way A D converter does not understand signals correctly USB connection could be wrong Repeat the charge procedure checking the LED colour sequence Insert always first the jack in the DL and then the plug in the network plug Wait at least 30 minutes to allow the battery to become colder and go back in the appropriate temperature range Turn on or set the back light through the special keys see paragraph special combination keys in the reference DL manuals If this procedure will not solve the proble contact SISGEO assistance Reset through keys combination see special combination keys in the DL manual Reconnect sensors in a correc
21. cable USB cable Atte Rev 2 31 01 2013 JlPage e O v gt SISGEO Portable Dataloggers User Manual SISGEO new LEONARDO 0CDL400N000 The new Leonardo DL has been developed to make and store readings obtained from various instruments including analog digital and vibrating wire instruments The New Leonardo DL is mainly composed by Shoulder and shipment bag OCDLOBAG927 Battery charger for NiMH batteries OECAB12VNMB Flying cable 1 MIL connector and 6 alligator clips ground OECAV7P6A00 IP68 USB cable for PC connection CD ROM Manuals Smart Manager Suite Shipment bag Shoulder bag Flying cable USB cable Caricabatteria Rev 2 31 01 2013 lPage leds O X gt SISGEO Portable Dataloggers User Manual SISGEO GALILEO OCDL100VW00 The Galileo DL has been developed to make and store readings obtained from vibrating wire instruments and its thermistor NTC The Galileo DL is mainly composed by e Shoulder and shipment bag OCDLOBAG927 e Battery charger for NiMH batteries OECAB12VNMB e Flying cable 1 MIL connector and 4 alligator clips ground DECAV7P4A00 e P68 USB cable for PC connection e CD ROM Manuals Smart Manager Suite Shipment bag Shoulder bag Flying cable USB cable Battery charger Rev 2 31 01 2013 IPage NN O V gt SISGEO Portable Dataloggers User Manual SISGEO ARCHIMEDE OCDL300INCL The Archimede DL has been developed to make and st
22. cally advance to the next channel You may proceed to read all channels manually by pressing the ENTER key for each channel You may return to the list of channels in the Multiplexer by pressing the ESC key You may also let the DL do all the work select the first instrument you wish to read and click the Scan button by NEXT scroll and PREVIOUS scroll the DL will start reading at the selected channel waiting for the warm up time required for each instrument and proceed recording a reading for each instrument till it reaches the end of the Multiplexer You may press ESC key anytime to interrupt the process If the measurement is not successful will be displayed a dialog box i e Check connection before continuing Error reading instrument Check connections before continuing Pressing ESC or selecting CANCEL will be shown the error with a red marking Rev 2 31 01 2013 IPage y N O r Portable Dataloggers User Manual SISGEO MUX2 X 1 1VK4200VC V 2 DTE2 Y 3 DTE3 4 4 MEXID1 4 5 MEXID2 Y 6 MEXID3 READING SISGEO S DIGITAL INCLINOMETERS CHAINS The reading procedure of SISGEO digital inclinometers chains is equivalent to that of Multiplexer standard Refer to READING STANDARD MULTIPLEXER In this case is necessary to connect the flying cable to the inclinometer chain switch panel and to the DL Readings will be performed in the same way of a st
23. dings are performed To view the site s list select Configuration in the main menu then select Sites The list of sites is initially empty To add a new site make sure that the edit box at the bottom of the screen is active you should see a blinking cursor in it and type the name for the new site then press ENTER Configuration sites MY SITE The new site will be shown in the list on the page Configuration sites Rev 2 31 01 2013 IPage Portable Dataloggers User Manual The name of the site as well as the name of a Multiplexer Switch Panel Worklist or Inclinometer Tube should be composed of the same characters used for Microsoft Windows valid file names so all characters except the following lt gt To delete a site select it in the sites list and make sure that the site list has focus then press the DEL key if the site is not empty the DL will ask to confirm the operation Configuration sites TT yw IT A Warning Delete site MYSITE SIT Rev 2 31 01 2013 IPage Portable Dataloggers User Manual CONFIGURING INSTRUMENTS SINGLE Every instrument analog digital and vibrating wire must be configured in the site to which they belong SISGEO s digital instruments can be configured only in reduced form since every configuration parameter serial number calibration coefficient etc are already included in the instrument To browse or edit instr
24. display turned inside During the transport it is advised to use the shoulder bag and to avoid bumps Rev 2 31 01 2013 IPage Portable Dataloggers User Manual BATTERIES Each DL is powered by an internal rechargeable NiMh battery If properly used the NiMH batteries are rated for at least 500 discharge cycles An effect known as the memory effect which will degrade the readout s performance during use may occur if the batteries are left under charge for some days or if they are repeatedly partially discharged In order to prevent this it is recommended to use exclusively the battery charger supplied with the DL and to cycle charge and fully discharge the batteries at least once every two three weeks The batteries should be charged only when they are completely discharged and not before charge it before only when you have to use the DL Furthermore if the DL is not going to be used for an extended period it is preferred to store the DL with the batteries fully charged Well charged batteries provide at least 8 hours of continuous use this means that the batteries provide charge for more than a day s work If the DL is not used for months the batteries lose their capacity due to the auto discharge The first time a battery charger is connected this could signal green also if the batteries are not fully charged it is advised to repeat the charge cycle twice Using a good battery a full battery charge allows a non
25. dition to the standards listed above the user must comply with the existing legislation on safety and health of employees in the workplace Check the product for damages caused by transport Verify that your package includes all standard accessories and any accessories required In case contact SISGEO and or the distributor The use of the portable datalogger shall be done only after the proper connection and following the configuration needed so the user must carefully perform all the operations described herein SISGEO will not be liable for inconveniences damages accidents etc due to lack of knowledge or non application of the requirements contained in this manual The use any possible maintenance or repair of the equipment is allowed only to skilled and authorized operators These operators must be physically professionally and intellectually capable For information or orders of spare parts always specify the serial number reported on the identification plate showing on the back of device When replacing parts use only ORIGINAL SPARE PARTS The use of unoriginal SISGEO spare parts may cause irregular functioning and dangers for people and objects The product is not fit for installation in small and or unventilated environments with a high humidity range or in presence of inflammable or explosive liquids All the instruments and the equipment furnished are not suitable for installation in potential dangerous area or when the u
26. e new Leonardo Leonardo Galileo Datalogger oe Leonardo Datalogger ee esc del gt 0 o e a 1234 1 678907 User Manual Portable Dataloggers User Manual INDEX NOTE ON SYSTEM UTILIZATION WASTE DISPOSAL SYMBOLOGY IDENTIFICATION PLATE DL OVERVIEW INTRODUCTION LEONARDO OCDL200UNO0 new LEONARDO 0CDL400N000 GALILEO OCDL100VW00 ARCHIMEDE OCDL300INCL ACCESSORIES and SPARE PARTS DL STORAGE AND TRANSPORT BATTERIES Battery charger Internal temperature How to use the battery charger Charge cycle and LED indication USER INTERFACE Edit boxes Buttons Lists Radio buttons Tuning backlight On line help THE MAIN MANU CONFIGURING SITES CONFIGURING INSTRUMENTS SINGLE CONFIGURING MULTIPLEXER STANDARD CHAIN OF DIGITAL INCLINOMETER SWITCH PANEL and WORKLISTS EDITING A MULTIPLEXER CHANNELS STANDARD EDITING SISGEO S DIGITAL INCLINOMETER S CHAIN PARAMETERS EDITING SWITCH PANELS CHANNELS EDITING WORKLISTS ITEMS READING INSTRUMENTS SINGLE READING DIGITAL S INSTRUMETS SINGLE BROWSING INSTRUMENT READINGS Rev 2 31 01 2013 Pag 4 Pag 5 Pag 5 Pag 6 Pag 7 Pag 7 Pag 8 Pag9 Pag 10 Pag 11 Pag 12 Pag 12 Pag 13 Pag 13 Pag 14 Pag 14 Pag 15 Pag 16 Pag 20 Pag 21 Pag 21 Pag 22 Pag 22 Pag 22 Pag 23 Pag 24 Pag 26 Pag 36 Pag 39 Pag 41 Pag 42 Pag 44 Pag 46 Pag 50 Pag 52 DiPage Portable Dataloggers User Manual READING STANDARD INSTRUMENTS SINGLE Pag 53 R
27. e added to the Switch Panel To delete an instrument from the Switch Panel just select it and press DEL key A confirmation window will appear When you have finished press the ESC key Rev 2 31 01 2013 IPage Portable Dataloggers User Manual EDITING WORKLISTS ITEMS After creating a new Worklist press ENTER after selecting a Worklist in the list of Work lists for the current site the display will show the channel assignment for the current Worklist Edit worklist E d When first created Work lists are empty click the Add button to add an instrument the DL will display a page for selecting the instrument to add Select instrument Ei D2321002 as 420MAGEN2W D232T003 420MAGEN22 ELI420MA Select instrument and press ENTER The DL will display a page in which you may edit a Position and a Notes field Rev 2 31 01 2013 Mii Page Portable Dataloggers User Manual Select position ENC Name 420MAGEN2W Position Notes Write in the Position field something that will help you to locate the instrument when later you will be performing measures Select position AT Name 420MAGEN2W Position North Notes Press ENTER to add the new item in the Worklist To delete an instrument from the Worklist just select it and click DEL key A confirmation window will appear When you have finished press the ESC key Rev 2 31 01 2013 IPage e
28. e temperature decrease under 70 C So if after the battery charge the DL won t switch on wait for the battery cooling until it returns within an adequate temperature range HOW TO USE THE BATTERY CHARGER The battery charger is started by connecting the jack to the readout and then connecting the battery charger at the voltage line NOTE To avoid damages always insert the battery charger jack in the DL before connecting the battery charger at power supply network likewise before disconnecting the battery charger jack from the readout disconnect the battery charger from the power supply network The LED on the battery charger will be yellow before the fast charge starts and then the LED changes to orange When the batteries are fully charged the LED will be green Do not leave the battery charger connected to the DL for more than 24 hours If the battery voltage is less than the normal one the LED will then indicate error by flickering green and orange light Rev 2 31 01 2013 IPage Portable Dataloggers User Manual CHARGE CYCLE AND LED INDICATIONS Battery not connected Battery initialisation and analysis Fast charge Green with intermittent yellow flash Top off charge Trickle charge Alternating orange green Error Connecting the battery charger at the voltage the LED will become orange for the first 5 7 seconds then it turns to yellow when the initialisation and the analysis starts If the batt
29. elected but it is possible to edit them Use the UP and DOWN keys to select the wire you need to edit e g G Shield E Instrument cabling 4 20mA 2 wire single O Errerreres gt WK G Shield lt lt Then press the NEXT scroll key to move to the list for the primary color on the right and use the UP and DOWN keys there to select the wire color E Instrument cabling 4 20mA 2 wire single gt WW 3 Shield Jarra x Then click the PREVIOUS scroll key to get to the wires list on the left E Instrument cabling 4 20mA 2 wire single gt d Rev 2 31 01 2013 IPage Portable Dataloggers User Manual If the wire has two colors Select the wire in the first list Press the NEXT scroll key to get to the primary color list in the middle Select the primary color by UP or DOWN keys Press the NEXT scroll key to get to the secondary color list on the right Select the secondary color by UP or DOWN keys Press the PREVIOUS scroll key twice to get to the wires list on the left To delete the colors for a cable Select the wire in the first list Press the NEXT scroll key to get to the primary color list in the middle Press the DEL key To delete just the secondary color Select the wire in the first list Press the NEXT scroll key to get to the primary color list in the middle Press the NEXT scroll key to get to the secondary color list
30. ent sets of parameters for platinum thermo resistance PT100 instruments P111PT10 nstrument calibration ro 100 0 a 3 9083e 3 57758 7 c 4 183e 12 Save Rev 2 31 01 2013 IPage Portable Dataloggers User Manual Calibration values for PT100 instruments should not be changed by user The calibration requires different sets of parameters for NTC thermistor T3100GKA Instrument calibration AT 125 Boooo a 0 0033539 b 0 0002578 C 25364809 d 5 3216393 Save Calibration values for NTC thermistor should not be changed by user For vibrating wire instruments two pages of parameters must be entered The first page refers to the linearization polynomial polynomial coefficients have the same meaning they have in mono instruments The second page contains the gauge parameter for the wire and the coefficients for the thermistor Instrument calibration E 1 gauge 125 3000 0 a 0 0033539 b 0 00025781 c 25364809 d 5 3216393 4 Save Rev 2 31 01 2013 IPage Portable Dataloggers User Manual If the gauge parameter is blank the user unit is calculated from digit s value using the polynomial defined from the user In this case will be displayed the digit reading If the gauge parameter is edited editato the user uniti s calculated from the pE using the polynomial defined
31. ents e VW Vibrating Wire instruments with relative NTC thermistor Some instruments may not be available due to the DL type being used See INTRODUCTION In this section you may read e Multiplexers SISGEO Multiplexer Box and digital SISGEO inclinometer chains e Switch Panels SISGEO Switch Pannel e Work lists they are not physical devices they are just a list of instruments to read possibly in different location They are designed to support the user in keeping track of different instruments to read In this section you may configure Instruments Multiplexers Switch Panels and Work lists In this section you may connect to a PC using the USB port some DLs support a Bluetooth module which is also managed in this section In this section you may set date and time select the language for the user interface and run a checkup for the DL iPage Portable Dataloggers User Manual CONFIGURING SITES DLs have a permanent memory used to store configuration data such as Instruments and Multiplexers as well as acquired data as Readings Also if the memory s maximum capacity is remarkable 2GB DL export and synchronization speed with the PC depends on the inner data quantity We advise not to charge exceedingly DL s memory and to use it only to save the DL s files All data in a DL is divided in sites how to define sites is up to the user but it is expected them to be named after the physical sites where rea
32. ery is connected the actual charging will start a few seconds later when the LED changes to orange When the battery is charged the LED will be green in approx 4 seconds This is only a signal to test the service When dv has been detected the start of the top off charge is indicated with a green LED with intermittent yellow flashes The LED will be green during trickle charge Rev 2 31 01 2013 IPage Portable Dataloggers User Manual USER INTERFACE To switch the DL on press the ON OFF key while keeping the INFO key pressed After a few seconds the DL will switch on and the display will show a start up page This page will display the type of DL and the version of the firmware At the bottom of the display the name of the DL will show up this is an user assigned name that can be used to distinguish between different DLs Keeping the name of different DLs distinct is important when importing data to a PC so that the source of the data can be traced DL type Firmware version 20120000 Unit Name At the upper right corner the display shows the current status of the battery the remaining charge is shown by the number of bars Press ENTER or wait a few seconds to display the Main menu Rev 2 31 01 2013 IPage Portable Dataloggers User Manual When the battery voltage drops below about 12 5 Volts the bars will turn red At about 10 5V 7 7 the DL will stop all activities then it will beep and switch
33. et the DL clock to run a self test and to change the user interface language Click the Utility button in the main menu Utilities 1 Set date amp time 2 Unit status 3 Set language SETTING DATE AND TIME Click the Set date amp time button in the Utilities menu to display the current date and time Set date amp time _Press_an arrow key to edit Press an arrow key to edit To change the current date and time click one of the arrow keys a cursor will be displayed on the first digit of the hours field Set date amp time E Press an arrow key to edit Rev 2 31 01 2013 MlPage ai y v Portable Dataloggers User Manual S ISGEO You may move the cursor using the arrow keys or change the current value by typing the new value with the numeric keys When you have finished editing you may either commit the new value by pressing ENTER or discard with ESC CHECKING DL STATUS Click the Unit status button in the Utilities menu to check the current status The DL will display a list of the tests being performed and mark each test for success or failure Unit status y Checking x New Leonardo ver 015 S Disk 1928736 kB V Keyboard X Time NOT SET Battery 12 0 AD converter 28 9C AD calibration 06 07 10 E No key should be pressed during the DL self test so if you keep a key pressed the keyboard test will fail The temperature displayed on the AD converter line
34. ge A vy NN y Portable Dataloggers User Manual S ISGEO Select position E Name D2321002 Notes Position It is possible to edit a notes field When finished press ENTER the instrument will be added in the selected position of the Multiplexer Edit mux 16 2 E t D232T002 A DA ROM To remove an instrument from a multiplexer just select it and press the DEL key A confirmation window will appear Some instruments need to use two consecutive channels on a Multiplexer When such an instrument is selected the fact that an additional channel is used is marked by a quote character Edit mux 16 2 0010 1 D232T002 da 2 ELI420MA NOA When you have finished press the ESC key Rev 2 31 01 2013 MY Pace Portable Dataloggers User Manual EDIT SISGEO S DIGITAL INCLINOMETER S CHAIN PARAMETERS After the creation of a new SISGEO s inclinometer chain press ENTER after having selected a chain in the list of the current site multiplexer the display will show the settings used to read the chain Digital inclinometers Mi Max addr LIEnergy saving Warmup Ss Delay s The parameters set here are used from the DL to read the digital inclinometers so they have to match exactly to the ones in the inclinometer s chain changing the parameters in this screen will not change the parameters set in the inclinometer s chain Please refer to the documents supplied from SISGEO
35. green shield S411HV90 Uniaxial in place inclinometer 24V 2100mV mV 1 red black white green shield S411P1XV Vertical in place inclinometer pass 1 0m mono 2 5V 200mV mV V 2 red black blue green yellow white shield S411P1XX Vertical in place inclinometer 1 0m mono 24V 20mA mA 3 red black shield S411SVXX Servo in place inclinometer 12V 5000mV mV 0 red white black yellow green shield S421HAXX Uniaxial SUB horizontal IPI 24V 20mA mA 3 red black shield S421HDXX Digital uniaxial SUB horizontal IPI 24V digital Sina 4 red black white green shield S421PVXX In place inclinometer mono 24V 400mV mV 2 red black yellow white shield S521HAXX Waterproof clinometer 24V 20mA mA 3 red black shield S521HDXX Digital waterproof clinometer 24V digital Sina 4 red black white green shield S521PVXX Waterproof clinometer mono 24V 400mV mV 2 red black yellow white shield S521SVXX Waterproof servo clinometer mono 12V 5000mV mV 0 red white black yellow green shield S531HAXX Clinometer 24V 20mA mA 3 red black shield S531HDXX Digital clinometer 24V digital Sina 4 red black white green shield S531PAXX Clinometer 4 20mA mono 24V 20mA mA 3 red black shield S531PVXX Clinometer mono 24V 400mV mV 2 red black yellow white shield S531SVXX Servo clinometer mono 12V 5000mV mV 0 red white black yellow green shield S700TLXX Tilt beam sensor 10 24V 20mA mA 3 red black shield S701HDXX Digital tilt beam sensor 24V digital Sina 4 red black white green shield S7RDSXXX RDS Railway
36. he requirements on the plates Failure to comply with these requirements could result in damage to the device and danger to the operator Rev 2 31 01 2013 lPage Portable Dataloggers User Manual DL OVERVIEW Display TFT Leonardo pf ES del Keyboard E JU 22 f o vam a a a E f JE Le ent ter ES ES Mini USB Connector for y PC connection record key SISGEO MILANO ITALY INTRODUCTION DL model Jack Plug for battery charger MIL Connector for instrument connection Depending on the type of your portable datalogger DL it is possible read different instrument types Analog Digital Probe Vibrating wire Leonardo Y Y New Leonardo Y Y Y Galileo Y Archimede Y For further details please see Appendix A iPage Rev 2 31 01 2013 e O V gt SISGEO Portable Dataloggers User Manual SISGEO LEONARDO 0CDL200UNO00 The Leonardo DL has been developed to make and store readings obtained from different analog and digital instruments except for vibrating wire instruments Leonardo DL can t perform inclinometer tests The Leonardo DL is mainly composed by Shoulder and shipment bag OCDLOBAG927 Battery charger for NiMH batteries 0ECAB12VNMB Flying cable 1 MIL connector and 6 alligator clips ground OECAV7P6A00 IP68 USB cable for PC connection CD ROM Manuals Smart Manager Suite Shipment bag Shoulder bag Flying
37. he selected item pressing the DEL key when the desired item is selected and when you are in configuration menus The DL will require a confirmation to avoid accidental deleting it doesn t happen if the item has no data inside Rev 2 31 01 2013 IPage Portable Dataloggers User Manual RADIO BUTTONS Radio buttons are used to select one of a few possible options To select an item move the selection to it clicking NEXT scroll or PREVIOUS scroll and press ENTER key Standard O Wire O Biaxial TUNING BACKLIGHT Backlight may be switched on and off by pressing the LIGHT key You may tune backlight level to adapt to field conditions Keep the LIGHT key pressed and press the PREVIOUS scroll key to increase light or the NEXT scroll key to decrease it ONLINE HELP In order to display online help press the INFO key actually no help on line is implemented Rev 2 31 01 2013 IPage Portable Dataloggers User Manual THE MAIN MENU The main menu gives access to all the functions of the DL Manual read Batch read Configuration Communication Utility Rev 2 31 01 2013 Main menu 1t Manual read 2 Batch read 3 Configuration 4 Communication 5 Utility del In this section you may configure read instruments and store readings Available instruments include e Standard analog and digital mono axial mono channel instruments e Biaxial analog and digital bi axial bi channel instrum
38. iezometer Digit red black white green shield PK45HXXX Vibrating wire pressure gauge Digit red black white green shield PK45IXXX Drive in vibrating wire piezometer 350KPa Digit red black white green shield PK45SXXX Vibrating wire piezometer Digit red black white green shield VK4000SM V W Shotcreate strain gauge Digit red black white green shield VK4000VS Vibrating wire surface strain gauge 4 043E 9 uE red black white green shield VK4100VK Spot weldable Geokon 4100 3 910E 8 uE red black white green shield VK4200VC Embedment vibrating wire strain gauge 3 814E 9 uE red black white green shield VK4200VN No stress vibrating wire embedment strain gauge 3 814E 9 uE red black white green shield VK4210VC Strain gauge Geokon 4210 3 568E 8 uE red black white green shield VKBAROXX Vibrating wire Rebar Digit red black white green shield BI AXIAL INSTRUMENTS Rev 2 31 01 2013 i Page 420MAGEN2W Generic 4 20mA 2 wires 20mA shield 420MAGEN3W Generic 4 20mA 3 4 wires 24V 20mA mA 3 shield DEX35SXX DEX in place inclinometer extensometer 24V 20mA mA red white black green shield ELI420MA 4 20mA transmiter 24V 20mA mA red white black green shield S412HAXX Biaxial in place inclinometer 24V 20mA mA red white black green shield S412HDXX Digital biaxial in place inclinometer 24V digital Sina red black white green shield S412HV10 Biaxial in place inclinometer 24V 700mV mV red black white green yellow blue shield S412HV20 Biaxial in place inclinometer 24V 1400mV mV red b
39. ing instruments it will not be possible to use the external pushbutton Click Remote management off button in the Communication menu to terminate SmartRemote mode Rev 2 31 01 2013 IPage Portable Dataloggers User Manual USING THE BLUETOOTH INTERFACE The BlueTooth interface allows transferring data to a PC or a SmartPhone equipped with a BlueTooth interface From the main menu select Communication then click Bluetooth the datalogger will beep and in a few seconds the BlueTooth interface will be activated and a page will be displayed for selecting the remote device to which data will be transferred Select BT device UM Check for BT devices This list is initially empty to add one or more remote unit to it make sure that they are visible How a BlueTooth device is made visible depends on the specific device for example when using Windows Seven you should open the BlueTooth settings windows in the lower right of the Windows bar and after selecting Open Settings make sure that the option Allow Bluetooth devices to find this computer is selected Your PC or SmartPhone should now be able to detect the DL The code required for pairing is 574832 Once the DL has been added to the list of devices of the PC or SmartPhone click the Check for BT devices button on the DL the PC or SmartPhone will be added to the list of BlueTooth devices Select BT device TT CMAGPC J ye Check for BT de
40. instrument is selected in the list Click on the Clear button at the bottom to clear the log of last readings this list will be filled again when reading instruments so that you may use it to keep track of the work being done Instruments that have a valid reading in the list are marked with a green checkmark A Browse button is also present that may be used to view values read on the selected instrument in the past it works exactly as the Browse button available when reading single instruments via the Manual Read button of the Main menu READING MULTIPLEXERS STANDARD When reading a Multiplexer the DL first displays a list of all instruments connected to the selected Multiplexer MIDI check marker gt ELI420MA hd fast reading Clear Browse Connect the flying cable OECAVIOMUXO for multiplexer measurement to the DL and to the Multiplexer board and to the Battery Pack Check carefully that the selected multiplexer matches the multiplexer physically connected to the DL a mismatch may cause damage to the connected instruments or the DL Rev 2 31 01 2013 IPage v o i i Portable Dataloggers User Manual SISGEO You may read a single instrument by selecting it in the list and pressing ENTER The DL will display a page with the value currently read on the selected channel Reading instrument 1 D2321002 You may record the currently read value by pressing ENTER the DL will automati
41. lack white green yellow blue shield S412HV30 Biaxial in place inclinometer 24V 2100mV mV red black white green yellow blue shield S412HV90 Biaxial in place inclinometer 24V 2100mV mV red black white green yellow blue shield S412PVXX In place Inclinometer biaxial 12V 400mV mV red black yellow white blue green shield S412SVXX Servo in place inclinometer biaxial 12V 5000mV mV red white black yellow blue green shield S522HAXX Biax waterproof clinometer 24V 20mA mA red white black green shield S522HDXX Digital biax waterproof clinometer 24V digital Sina red black white green shield S522PVXX Waterproof clinometer biax 12V 400mV mV red black yellow white blue green shield S522SVXX Waterproof servo clinometer biax 12V 5000mV mV red white black yellow blue green shield S532HAXX Biax clinometer 24V 20mA mA red white black green shield 5532 HDXX Digital biax clinometer 24V digital Sina red black black white green shield S532PVXX Clinometer biax 24V 400mV mV red black yellow white blue green shield S532SVXX Servo clinometer biax 12V 5000mV mV red white black yellow blue green shield Portable Dataloggers User Manual REX451XX S241DH30 S241DV30 S241HH30 S241SHXX S242DH30 S242DVXX S242HVXX S242SHXX S242SVXX S30PR12X S310PV2X SCLIN45X Rev 2 31 01 2013 PROBES DIGITAL PROBES T REX removable extensometer Digital horizontal inclinometer probe 30 Mono axial digital probe Horizontal inclinometer probe 30 Ho
42. lay press the 3 key while keeping the DEL key pressed scroll EMERGENCY RESET Should the DL become unresponsive press the keys A esc del dei p OFF and DEL keys at the same time the DL should g gt reset immediately E le de 12 Es 6 7 ON off 9 e a NOTE no data will be lost Rev 2 31 01 2013 IPage Portable Dataloggers User Manual FIRMWARE UPGRADE To upgrade firmware switch the DL off then press ca ese dei the following keys at the same time 1 3 9 and FIRE ci ENTER While keeping them pressed press the ise ON OFF key till the DL switches on 1 E The DL will display a blue screen and will be ready for eua 2 DEF GHI JKL R fi d 9 0 off Read Smart Manager manual for detail EARLIER FIRMWARE VERSION In case some instruments have been configured with an earlier version of the firmware any changes will not be applied to the instruments already configured To apply the changes introduced by a new firmware you should remove the instrument from the datalogger and re insert it If for example with a new firmware it has been changed the power supply of a instrument this one will be powered with the power supply set in the old firmware If you want to use the new power supply it is necessary to remove the instrument from the datalogger and re insert it Rev 2 31 01 2013 IPage A DON Y Portable Dataloggers User Manual SISGEO TECHNI
43. linometer s chain must NOT be configured Refer to the Configuring Instruments chapter for details about configuring instruments To configure any of these Selectors considering Work lists as a sort of virtual device select Configuration and then click the appropriate button for the type of Selector you wish to configure Configuration ENO 2 Instruments 4 Worklists 5 Multiplexers 6 Switch Panels The process is very similar for all of them except that different data is used to identify the position on the Selector of a given instrument First the DL will display a screen to select the site in which the Selector should be added then a list of the Selectors of the chosen type already defined in the site will be displayed Select work list E A wv When one or more Selectors are listed it is possible to delete one of them by selecting it in the list and pressing the DEL key the DL will ask the user to confirm this operation Rev 2 31 01 2013 IPage Portable Dataloggers User Manual It is also possible to make a copy of an existing Selector by selecting it in the list and clicking the Duplicate button the DL will ask the name for the new Selector Every list is initially empty so that the only chance is to press the key Create All lists are initially empty so that the only possibility is to click the New button The DL will display a screen asking the name for the new Switch Panel or Worklist N
44. off To limit battery consumption after three minutes without user activity the display will switch off after ten minutes the DL will switch off To switch the DL off press the ON OFF key while keeping the ENTER key pressed the DL will display a window on top of the current page with a bar at the bottom When the bar is completely filled the DL will ask to release all keys and then it will switch off Other keys combinations are described in the Special keyboard combinations chapter Rev 2 31 01 2013 IPage Ni y gt SISGEO Portable Dataloggers User Manual SISGEO The user interface is made of a series of screens containing control items similar to those available in Windows Configuration sites SITE NAME 1 SITE NAME 2 TETO Screens contain different items such as lists buttons edit boxes and check or radio buttons Only one of the controls on the screen has focus the currently focused control is highlighted in blue and normally indicates the action performed by pressing the ENTER key Configuration sites MO Active control SITE NAME 1 y TAN SITE NAME 3 lt If the selected control is an edit control characters typed on the keyboard will edit its content Configuration sites Text control Rev 2 31 01 2013 IPage Portable Dataloggers User Manual You may change the selected control by clicking the PREVIOUS scroll and scroll NEXT scroll key
45. on the right Press the DEL key Press the PREVIOUS scroll key to get to the wires list When you have edited the cable color press the ENTER key to get to the calibration page Rev 2 31 01 2013 IPage Portable Dataloggers User Manual For SISGEO s digital instruments is only possible to configure Name Note and Decimal Instrument identification m Name 532HDXX Notes Code 5532HDXX Unit Sin a x Decimals 4 Save It is not possible to configure the color scheme for this kind of instrument The calibration page for instruments depends on the instrument type SISGEO s digital instruments calibration is already included in each instrument so it is needed no calibration For the other instruments it is possible to enter a calibration polynomial with a degree of 1 to 3 that is used to convert from the electrical measure e g mA or mV to the physical unit measured by the instrument e g kPa Instrument calibration E Type Ch A A L B Initially the list of polynomials degrees is listed at the top of the screen Select the polynomial you wish to use with the UP and DOWN keys it is possible to select one of the following families of polynomials o Ax B e Ax Bx C e AX Bx Cx D Then click the NEXT button to edit the coefficients for the polynomial according to SISGEO s Calibration Report Rev 2 31 01 2013 IPage v O Po
46. ore readings obtained from inclinometer test both analog and digital inclinometers The Archimede DL is mainly composed by e Shoulder and shipment bag OCDLOBAG927 e Battery charger for NiMH batteries OECAB12VNMB e P68 external button for data storage Archimede DL OCDL300REMC e Flying cable 2 MIL connectors M F 7 pins OECAVO7V200 e P68 USB cable for PC connection e CD ROM Manuals Smart Manager Suite Shipment bag Shoulder bag Flying cable USB cable Battery charger IP68 external button Rev 2 31 01 2013 IPage Portable Dataloggers User Manual ACCESSORIES AND SPARE PARTS Flying cables 1 MIL connector and 2 alligator clips ground OECAV7P2A00 1 MIL connector and 4 alligator clips ground DECAV7P4A00 1 MIL connector and 6 alligator clips ground OECAV7P6A00 2 MIL connectors M F 7 pins OECAVO7V200 IP68 external button for data storage Archimede DL only OCDL300REMC Multiplexer measurement OECAV1OMUXO External 12V battery pack OCDLO12EXBP Internal Bluetooth module OCDLOBTOOTH this module shall be requested together with DL purchase order can be added later only by SISGEO Shoulder and shipment bag OCDLOBAG927 Battery charger for NiMH batteries 0ECAB12VNMB External 12V battery pack Multiplexer measurement cable DL STORAGE AND TRANSPORT To store correctly the DL it is advised to use the supplied bag Put carefully the DL in the suitable compartment with the
47. r test Archimede DL only These two uses are not compatible when an external push button is connected the USB cable cannot be used and connecting an USB cable when the DL expects a push button will cause the PC to issue a warning that the USB detection failed To start using the USB select Communication in the main menu Communication Ei t USB Disk 2 USB Calibration 3 Bluetooth 4 Remote management Before starting the communication with the PC is necessary to have already installed the SMART MANAGER SUITE see its manual for the installation and software use USE WITH SMART EXPORT AND SMART MANAGER To share data with SmartExport and SmartManager the DL must simulate an external disk for this click the USB Disk button and make sure that an USB cable connects the DL to the PC The DL will appear as an external USB disk If the SmartMonitor feature is enabled SmartManager will start automatically Please refer to the SmartExport and SmartManager manuals for details Rev 2 31 01 2013 IPage Portable Dataloggers User Manual USE WITH SMART DATACAL This function is reserved for SISGEO technicians USE WITH SMART REMOTE SmartRemote is a software that replicates the DL screen and keyboard on a PC this may be useful for using the DL with a projector in a class or to provide support to a remote user controlling the PC through Internet using such programs as VNC Click the Remote m
48. res uEpsilon Physical unit Hs Hz Digits Rev 2 31 01 2013 E Page p v S O vk Portable Dataloggers User Manual SISGEO yw yw VK4000SM uEpsilon kPa if configured by the user VK4000SM Digit if not configured default VK4000SM uSeconds VK4000SM VK4000SM Digits The pe value will be shown only if it had been inserted gauge value during instrument s definition If you insert a gauge value 0 a screen with pe will be displayed but the values will remain 0 Note that these are just the results of different computations on a single physical measure namely the frequency of the vibrating wire Rev 2 31 01 2013 49 IPage Portable Dataloggers User Manual READING DIGITALS INSTRUMENTS SINGLE The procedure for reading SISGEO S single digital instruments configured from the user is equivalent of single analog instruments see paragraph READING SINGLE INSTRUMENTS To read SISGEO S digital inclinometer chains see paragraph READING SISGEO S DIGITAL INCLINOMETER CHAINS The only precaution is to be certain that the digital instrument to be read DOES NOT have the function energy saving enabled otherwise will be displayed the message The instrument is not connected The reading shows is already in physical unit see APPENDIX A for further details Reading instrument 242SV30 Sin 0 During the reading of a digital instrument pressing the RIGHT key it is possible
49. rical load cell 2 5V 2 0mV V mV V 3 red black blue green yellow white shield L3400ASO Surface strain gauge 400mm 24V 20mA mA 3 red black shield L3400VSO Surface strain gauge 400mm 2 5V 2 0mV V mV V 3 red black blue green yellow white shield L3400VSC Surface strain gauge 400mm 24V 10mV mV 3 red black white green shield P23510XX Drive in piezometer 24V 20mA mA 3 red black shield P235SXXV Electrical piezometer 2 5V 2 0mV V mV V 3 red black blue green yellow white shield P235SXXX Electrical piezometer 24V 20mA mA 3 red black shield P251QXXX V notch level gauge 1 0m 24V 20mA mA 3 red black shield P252AXXV Pressure transducer 2 5V 3 0mV V mV V 3 red black blue green yellow white shield P252AXXX Pressure transducer 100KPa 24V 20mA mA 3 red black shield P252CXXV Removable piezometer 2 5V 2 0mV V mV V 3 red black blue green yellow white shield P252CXXX Removable piezometer 24V 20mA mA 3 red black shield P252RXXV Vented pressure transducer 2 5V 3 0mV V mV V 3 red black blue green yellow white shield P252RXXX Vented pressure transducer 24V 20mA mA 3 red black shield QVLIV100 V notch float level transducer 24V 20mA mA 3 red black shield S411HAXX Uniaxial in place inclinometer 24V 20mA mA 3 red black shield 5411 HDXX Digital uniaxial in place inclinometer 24V digital Sina 4 red black white green shield S411HV10 Uniaxial in place inclinometer 24V 700mV mV 2 red black white green shield S411HV20 Uniaxial in place inclinometer 24V 1400mV mV 1 red black white
50. rizontal probe Digital horizontal inclinometer probe 30 Biax Digital inclinometer probe Inclinometer probe Horizontal probe Servo inclinometer probe Spiralmeter probe Tilt probe for cased borehole Tilli portable tiltmeter 12V 24V 24V 12V 12V 24V 12V 12V 2 5V 2 5V 12V 10000mV digital digital 5000mV 5000mV digital digital 5000mV 5000mV 5000mV 400mV 400mV 5000mV 20000 Sina 20000 Sina Degrees Degrees 20000 Sina 20000 Sina 20000 Sina Degrees 20000 Sina Degrees 20000 Sina Degrees Mi Page Portable Dataloggers User Manual SPECIAL KEYBOARD COMBINATIONS SWITCH ON To switch the DL on keep the INFO key pressed and esc lua Es press the ON OFF key till the display switches on weed scroll S 7 8 9 ES SWITCH OFF To switch the DL off keep the ON OFF key pressed ca ese dei a and press the ENTER key till the DL switches off pog SE i 1 KIE ABC 2 3 4 GHI E JKL ha a 6 e 9 ED ALTERNATE DISPLAY MODES When reading instruments the DL displays the physical value read by the instrument o To read the raw hexadecimal values read by the AD Alm del p converters press the 1 key while keeping the DEL key z K EL gt pressed o e To read the electrical values read by the AD 1 A 33 pm e converters press the 2 key while keeping the DEL key MNO PQRS TUV WXYZ pressed osos E o To revert to normal disp
51. rtable Dataloggers User Manual SISGEO Instrument calibration MT vr ene Type Ax Bx Cx D Ch A gt RESULTS A H 452e 6 B 3 110e 5 C 3 453e 2 D 4157e1 157 e 1 When you have finished entering parameters click the Save button the newly created instrument will be displayed in the instruments list for the site Edit instruments D232T001 Duplicate After you have created some instruments you may make a copy of an existing instrument by clicking the Duplicate button The DL will create a new instrument which is an exact copy of the selected instrument Instrument identification O Name 232T001 Notes Code D232T XXX Unit mA Warmup Decimals 3 You must change at least the name of the new instrument before saving because two instruments with the same name cannot coexist in one site Rev 2 31 01 2013 IPage Portable Dataloggers User Manual Instrument calibration Warning Name is duplicate D232T001 OK Save If you fail to give a new name for the instrument or in any case when using an existing name for a new instrument you will get a warning message When entering the calibration for a dual instrument you will be asked to enter the coefficient for two polynomials to be used for the linearization of the first and the second channel Instrument calibration E Type Ch A Ch B AD B Save The calibration requires differ
52. rument cables to the alligator clips To avoid damage to the DL or to the instrument take care to not make short circuit with clips of the flying cable Check that the cable is connected correctly and that the instrument type is compatible with the one selected on the DL description in the upper part of the screen an erroneous connection may damage the DL or the instrument Press the ENTER key to start measuring the instrument Reading instrument ENO D232T002 mA Rev 2 31 01 2013 IPage vtd v gt SISGEO Portable Dataloggers User Manual SISGEO If you press ENTER while the reading is being displayed the current value will be recorded in the history file a beep will confirm recording The history file may be browsed for readings of a selected instrument by clicking the Browse button in the Instrument selection window Please note that it is not possible to record readings performed with standard instruments not configured from the user Press ESC key when you are finished reading the instrument If the DL detects a problem with the instrument it will display a dialog Reading instrument OO Error reading instrument Check connections before continuing Press ENTER to record You should fix the problem and click OK or click Cancel to terminate the operation When the instrument being read is a vibrating wire instrument pressing the RIGHT and LEFT key you may cycle through the following measu
53. s on the left side of the keyboard As all keys they have an auto repeat behavior when held pressed All controls in a page are in circular list so that clicking NEXT scroll when the last control is selected moves the selection to the first control of the screen Similarly clicking PREVIOUS scroll on the first control moves focus to the last control Rev 2 31 01 2013 IPage Portable Dataloggers User Manual EDIT BOXES An edit box is used to display and edit text when text to be entered is a number either an integer or a number with decimals the numeric keys and the decimal point are used to directly type the digits and decimals separator The key is used to enter a or sign instead the e for the exponent part Just press the key the DL will show a list of characters Press the key repeatedly till the character you wish to insert is selected then wait till the list of characters disappears and the selected character will be inserted in the edit box When you need to enter text all the numeric keys and the and the keys behave in this way press any of these keys repeatedly to enter the desired character Press the DEL key to delete the character on the left of the cursor If you keep the DEL key pressed for about a second the content of the edit box is deleted quick delete Rev 2 31 01 2013 9 The characters available for each key are
54. se of explosion proof components is foreseen The electrical connections must be executed by a qualified installer observing the effective regulations The manufacturer reserves the right to make changes in case of any manufacturing or commercial need without notice It will attempt to ensure that user manuals are updated in order to reflect functional product revisions Rev 2 31 01 2013 MiPage Portable Dataloggers User Manual WASTE DISPOSAL According to the European standard 2002 96 CE the disused instrument must be disposed in a correct way The recyclable materials are recovered in order to avoid the environmental damage For more information please contact your waste disposal service or the EE instrument retailer SYMBOLOGY Here are the symbols used in this manual to alert the reader Attention This operation must be executed only by specialized personnel W Pay particular attention to the following information Rev 2 31 01 2013 IPage p y S xy Portable Dataloggers User Manual S ISGEO IDENTIFICATION PLATE Each portable datalogger have two types of identification plates aii vv One of these shows the product registration Serial Number and is on the back of DL gt S e E O no italy 2d Number It is important to communicate this data when requesting information concerning the product The second plate is always located on the back of the DL Follow t
55. stop use of at least 8 hours this means that with a full charge it is possible to work on site for more than a day BATTERY CHARGER The battery charger supplied is a microprocessor controlled with rapid charge in less than 3 hours The input voltage range is universal 90 264 VJ This battery charger uses a method called dv detection this method is based on the fact that the voltage drops over the NiMH cells when the batteries are fully charged this voltage drop is detected when the voltage has dropped a certain percentage from the highest value and the charge will be automatically completed If this voltage drop does not occur the battery charger has a safety timer which will terminate charging after a given period of time to avoid batteries overcharging For battery cells which have been idle for a long period of time the voltage could drop in the first part of the charge cycle For this reason a start timer is built into the battery charger to prevent dv detection in the first minutes of the charge cycle Don t take instrument readings with battery charger connected to the DL Rev 2 31 01 2013 IPage Portable Dataloggers User Manual Don t use a different type of battery charger It is necessary use only the furnished battery charger OECAB12VNMB INTERNAL TEMPERATURE If for any reason the internal temperature in the DL is more than 70 C there is a safety system that disconnects the battery until th
56. t to read SISGEO s digital Inclinometer s chains Pay attention to the difference between Multiplexer Standard and digital Inclinometers the DL settings are totally different Refer to the chapter EDIT SISGEO S DIGITAL INCLINOMETER CHAIN PARAMETERS for details Rev 2 31 01 2013 IPage ai vy NN v Portable Dataloggers User Manual S ISGEO EDITING A MULTIPLEXER CHANNELS STANDARD After the creation of a new multiplexer press ENTER after having selected a Multiplexer in the list of Multiplexers for the current site the display will show the channel assignment for the current Multiplexer Edit mux 16 2 E 1 gt The first few channels are visible and the first channel is selected Press the DOWN key to change the selected channel and to scroll the list The number of channels in the Multiplexer as well as their type was set when the Multiplexer was initially created and cannot be changed now there is consequently no way to add or remove channels you may just assign an instrument to a channel or clear such an assignment To select an instrument for the current channel press ENTER the display will show a list of all the instruments defined in the current site Select instrument E D2327002 ad 420MAGEN2W D232T003 420MAGEN22 Select an instrument and press ENTER again the display will show the current position in the Multiplexer for the selected instrument Rev 2 31 01 2013 IPa
57. t way verifiying connection scheme Perform automatic diagnostic directly on DL Utilities gt Unit Status menu if one or more red check marks pop up contact SISGEO assistance Verify the instrument conncections and click OK Turn off and turn on the DL and reset Check that USB cable is correctly inserted both in the PC and in DL port DL showed Calibration file is not valid The calibration file is lost or damaged Call SISGEO for assistance DL showed Instruments is not compatible DL showed Instruments is not connected The selected instrument is not compatible with the instrument connected to the DL The energy saving function is enabled The connections to the instruments are incorrect Select the correct instrument and repeat the reading Disable the energy saving function only for Sisgeo digital inclinometer or wait for the time necessary for the awakening of the sensors and eventually check the configuration only for Sisgeo digital inclinometer chains Reconnect the instrument properly and repeat the reading Portable Dataloggers User Manual ASSISTANCE Sisgeo S r l is aware of the importance covered by the after sales assistant service therefore Sisgeo Technical Support is structured to offer the following services REPAIRS AND MAINTENANCES During the warranty period we assure that the equipment supplied is free from defects in materials for a standard and appropriate use Repairs
58. to display the temperature read from the probe Lettura S242HDXX Ee Rev 2 31 01 2013 IPage Portable Dataloggers User Manual Attention this function is possible only if it used a digital instrument If the DL discover an incompatibility with the digital instrument for ex Is selected a digital mono axial inclinometer while the connected inclinometer is bi axial will be shown a dialog box iy L E la Fa 41 Error rea 20 A Ins If the DL can t read the digital instrument connected will be shown the following dialog box Error reading instrument Instrument is not connected In this case verify the connections and that the instrument has the energy saving function is disabled Rev 2 31 01 2013 IPage pA y S y Y Y SEN SISGEO Portable Dataloggers User Manual BROWSING INSTRUMENT READINGS To browse readings recorded with an instruments select Manual read from the Main menu and select the instrument site as you would do for reading an instrument Now select the instrument whose readings you wish to browse and click the Reading button Note that it is not possible to browse readings performed with Standard Instruments as such readings are not recorded D2321002 420MAGEN2W D232T003 420MAGEN22 ELI420MA VK4000SM wv Browse The DL will display a list of readings 30 06 10 13 21 0 00 a 30 06 10 13 21 1001 30 06 10 13 21 2 002 30 06 10 13 21
59. uments defined in a site select Configuration in the Main menu then select Select site E Instruments MYSITE The DL will display a list of sites select the site you are interested in and press ENTER key The display will show a list of instruments configured for the given site Edit instruments E A wv The list of instruments is initially empty later on you will be able to edit any of the instruments defined in it by selecting it and pressing ENTER key To define a new instrument click the New button Rev 2 31 01 2013 IPage Portable Dataloggers User Manual pe O Y 1A SISGEO New instrument E lStandard O Biaxial 420MAGEN2W 420MAGEN3W D232T XXX D241A 200 D313FAXX O Wire 7 A The categories of instruments are listed at the top of the screen select the category for your instrument and press ENTER key New instrument Standard OBiaxial 420MAGEN2W 420MAGEN3W D232T XXX D2414 200 D313FAXX O Wire E 3 A The selection will pass to the list of instrument types of the given category select the instrument type according to your instrument and press ENTER key Instrument s type for each kind are listed in Appendix A The display will show configuration data for your instrument Instrument identification E Name p232TXXX Notes Code D232TXXX Unit Warmup Decimals 3 Rev 2 31 01 2013 Mil Pace MiP a g Portable Dataloggers User
60. vices To send data to a remote BlueTooth device select it in the list and press the ENTER key Rev 2 31 01 2013 IPage Portable Dataloggers User Manual Select site ii The DL will show a list of sites When using a PC you should now select the Receive a File option in the BlueTooth menu Select the desired reading file for Archimede DL or site for other DL and press ENTER the DL will start sending the acquisitions file Sending through Bluetooth Um sending file content a tt t i O The PC or SmartPhone that is receiving the data may ask you to authorize the reception or storage of data Rev 2 31 01 2013 IPage Portable Dataloggers User Manual There are some precautions to take with this Operative System OS CINDROID e The user should use an application that allows data transfer through Bluetooth because this feature is not natively supported by the OS In the Android Market there are some free application SISGEO suggest a free application called Bluetooth File Transfer very appreciated by users recommended on many sites and forums e This application should be initiated and maintained in the background if you close it the SmartPhone does not receive the file e Once received the file is saved in the default directory of the SD inside the smartphone You should find the file and then you should press and hold a few seconds it will be open a menu selecting Sharing you