Contents
1. VitaGuard VG 310 The Pulse Oximeter Monitoring the vital signs of patients and other risk groups is particularly difficult in situations where movement cannot be avoided Especially at home in emergency situations or during patient transport moni toring devices are needed which provide reliable and precise measurement of physiological values GETEMED s VitaGuard VG 310 pulse oximeter was de signed with these requirements in mind and safely and effectively monitors oxygen saturation SpO and pulse rate in both ambulatory and clinical environments Comforting Monitoring Monitoring can be accomplished at any time and in al most every place The VitaGuard VG 310 incorporates the Masimo SET technology Signal Extraction Tech nology and generates acoustic and visual alarms when the measured pulse rate or oxygen saturation values violate the limits set by the operator A technical alarm is emitted and a corresponding message displayed should the sensor become loose A port is also pro vided for connecting the monitor to an external alarm unit or a nurse call unit Extensive Data Storage In the event of a physiological alarm the measured val ues their associated waveforms and the monitor set tings for selectable periods prior to and after the event are automatically stored Over 400 such events can be Ogetemed 135 mm Features Monitored parameters Oxygen saturation pulse rate Operating time with batte
2. 9 info getemed de www getemed de
3. recognition Distributor SpO Monitor SpO range 1 100 Resolution 1 Accuracy 3 digits for SpO above 70 Selectable from 50 100 Minimum APOD Adaptive Probe Off Detection standard maximum Alarm settings Sensitivity Memory Event trend full disclosure and compliance memories Storage functions Storage capacity Up to approx 400 events depend ing on pre alarm and post alarm settings 144 h trend 16 h full disclosure Stored data SpO pulse rate signal IQ plethys mograph perfusion index status analog inputs AUX 1 amp 2 Classifications Product classification Ilb according to MDD 93 42 EEC Ingress protection IP 21 according to DIN EN 60529 German 21 30 02 1002 Hilfsmittelnummer Environmental Conditions Operating temperature 5 40 C Relative humidity 5 95 non condensing Storage and transport 40 70 C temperature range Standard Delivery VitaGuard VG 310 SpO patient cable SpO disposable sensor power adapter NA 3000 2 NiMH power pack user manual pouch including belt transport case Optional Accessories Automobile power adapter NAK 3000 2 wide range of SpO sensors disposable and reusable external alarm unit clinic mounting frame VitaWin analysis software Subject to change Manufactured by Ogetemed GETEMED Medizin und Informationstechnik AG OderstraBe 77 14513 Teltow Germany Telephone 49 3328 3942 0 Telefax 49 3328 3942 9
4. ries 8 h minimum Displays Graphical LCD display 4 LEDs Memory modes Event trend full disclosure and compliance Alarm notification Acoustic and visual Data transfer USB port captured in the event driven memory Both manual and interval driven data storage is also possible Further more additional limits may be set to capture events silently for example if the silent SpO lower limit is set to 92 then once the SpO value falls below this limit the event will be silently registered by the monitor Parallel to the event driven memory the VG 310 incor porates a 144 hour trend loop memory and a 16 hour full disclosure loop memory for continuous data storage Innovative Technology Easy to Use Considering all its features the versatile monitor weighs only approx 700 grams The clearly arranged layout of the control elements ensures ease of opera tion not only for trained clinical personnel but also for caregivers without previous medical or technical train ing The numerous ways of powering the monitor be it via the mains supply the rechargeable power pack single use batteries or using the car power adapter allow for a wide range of applications Comprehensive Data Evaluation The stored values and waveforms can be viewed directly on the monitor s high resolution graphical LCD display Alternatively using GETEMED s VitaWin software the event trend full disclosure and compliance recordings can be transfe
5. rred to a PC via the USB port visualized Maso El evaluated and documented lt gt wo Oo 1 st VitaGuard VG 310 Technical Data General Weight Approx 700 g with power pack 205 mm x135 mm x 45 mm 4 8 V NiMH power pack or 4x 1 5 V alkaline LR6 batteries 9 V power adapter NA 3000 2 Power adapter Input 100 240 V 50 60 Hz NA 3000 2 400 mA Output 9 VDC 1 5 A Power pack lt h recharge time Dimensions Power supply Operating time gt 8 h with power pack or batteries Replace battery message Message on LCD display Battery exhaustion message Visual and acoustic warning Keys 6 pushbuttons SpO connector 14 pin mini ribbon connector type BF input Mini USB to connect with a PC AUX connector features Interface for modem external alarm unit output nurse call unit output and 2 analog inputs AUX 1 amp 2 4 LEDs and a graphical LCD dis play 320 x 240 dots with backlight when powered by external or auto mobile power adapter USB connector Display elements Alarm warnings Visual and acoustic as per DIN EN 60601 2 49 and DIN EN 60601 1 8 Pulse Rate Monitor Method Pulse oximetry Pulse rate range 25 240 min Resolution 1 min Accuracy 3 digits without motion 5 digits during motion Bradycardia 30 35 175 180 min alarm settings Tachycardia 100 105 250 255 min alarm settings Green LED and selectable beep tone Signal
Download Pdf Manuals
Related Search
Related Contents
BOAT BOILER Eminent N-CASO Netbook case 11" VECTRON CT user manual Panasonic TY-TPEN1PBU WD My Cloud EX2 - Western Digital Copyright © All rights reserved.
Failed to retrieve file