Home

ADEMCO 6162RF Keypad / Transceiver – User Guide

image

Contents

1. for 3 seconds The screen displays the keypad s address 2 Press to move to the USER CODE entry screen 3 Enter 0 and then press to save and move to Delete Devices screen 4 Press to decline and exit When Single Button Arming is disabled a valid user code is required to arm the system with the Arming keys FUNCTION KEYS The Function keys may be programmed by the installer for special functions or alarm activations Key pairs ial ang may also be programmed for alarm activations B or an To activate the Function keys press and hold the key for at least 2 seconds key pairs are activated Cor 3__Jand _ immediately D Check with the system installer for more information COMMERCIAL STAY MODES Commercial Systems Stay Modes For commercial controls if Stay Mode 1 Stay Mode 1 2 is programmed refer to the control s manuals and the table on Low _ 2 Stay Mode 2 the right for Stay mode arming Stay Mode 3 both Stay 1 and Stay 2 modes SOUNDER e Two tone sound burglary and audible panic alarms e Pulsing sound fire or carbon monoxide alarms Refer to the system s user guide for details of audible notifications 3 TROUBLESHOOTING The error messages listed in the following table cause the keypad to produce a single ding tone The table describes the error messages and the corrective actions Display Corrective Action KeyPd LB Replace
2. the battery in the wireless keypad Open Ckt Contact your Installer Check 100 Contact your Installer FEDERAL COMMUNICATIONS COMMISSION FCC STATEMENTS The user shall not make any changes or modifications to the equipment unless authorized by the Installation Instructions or User s Manual Unauthorized changes or modifications could void the user s authority to operate the equipment Class B digital device Statement This equipment has been tested to FCC requirements and has been found acceptable for use The FCC requires the following statement for your information This equipment generates and uses radio frequency energy and if not installed and used properly that is in strict accordance with the manufacturer s instructions may cause interference to radio and television reception It has been type tested and found to comply with the limits for a Class B computing device in accordance with the specifications in Part 15 of FCC Rules which are designed to provide reasonable protection against such interference in a residential installation However there is no guarantee that interference will not occur in a particular installation If this equipment does cause interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures e If using an indoor antenna have a quality outdoor ant
3. Honeywell ADEMCO 6162RF Keypad Transceiver User Guide Alphanumeric Addressable Keypad Transceivers for use with Honeywell Control Panels incorporates functions of an RF Receiver and a 5800 Transmitter module 6162RF 4 Line Alpha Display Custom Zone Designators 2 System ARMED gt System NOT ARMED amp lt READY to Arm co C T c NOT READY to Arm CD C ss es Arming Keys a em Go Tae a Ae a eg aes Oooo Programmable Function Keys The Function Keys can be programmed for special functions or panic alarm activations See the Function Keys section and check with the system installer for more information Honeywell 6162RF KEYPAD LBLD UG 07 19 13_1 SETTINGS KEY FUNCTION Displays Settings Menu options details below The menu based user code 1 Set Time Date programming feature is only 2 View Event Log available with certain R K systems Check with the Press cermes ien ae T system installer for details on 1 Add a User features of your system 2 Delete a User 3 Assign Attr Note For Commercial controls some of the steps are different than described below Refer to the system User Guide for details on setting these options SETTINGS KEY OPTIONS Set Time Date 1 Press sermes and then to select Set Time Dat
4. e 2 Enter the Master User Code at the Enter Your Code prompt and press 3 Press to edit the time and date e Use the number keys to change the time and date shown e PM 0 _ AM e The navigation keys to move the cursor forward back e When done press to save and exit View Event Log i Press and then 2 to select the View Event Log 2 Enter the Master User Code at the Enter Your Code prompt and press 3 4 To exit press any key except the and keys Press to move forward or to move backward through events Reboot Keypad 1 Press and then B to Reboot the keypad The keypad beeps and the LEDs flash for several seconds Set User Codes 1 2 Press and then to select Set User Code Enter the Master User Code at the Enter Your Code prompt and press to see a user option screen Add a User Press to select Add a User e At Enter User No screen enter a unique two digit number and press G e Atthe New User Code prompt enter a new four digit user code and press amp _ Note Four digit user codes options 0000 9999 e The keypad will confirm the User setting and exit the Settings mode Confirmation Meaning Short ding User created successfully Long ding Error that user number already has a user code assigned No sound User not created try again If necessary delete the user and try aga
5. enna installed e Reorient the receiving antenna until interference is reduced or eliminated e Move the radio or television receiver away from the receiver control Move the antenna leads away from any wire runs to the receiver control Plug the receiver control into a different outlet so that it and the radio or television receiver are on different branch circuits Consult the dealer or an experienced radio TV technician for help INDUSTRY CANADA CLASS B STATEMENT This Class B digital apparatus complies with Canadian ICES 003 Cet appareil num rique de la classe B est conforme a la norme NMB 003 du Canada FCC IC STATEMENT This device complies with Part 15 of the FCC rules and RSS210 of Industry Canada Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received including interference that may cause undesired operation Cet appareil est conforme a la partie 15 des r gles de la FCC amp de RSS 210 des Industries Canada Son fonctionnement est soumis aux conditions suivantes 1 Cet appareil ne doit pas causer d interf rences nuisibles 2 Cet appareil doit accepter toute interf rence re ue y compris les interf rences causant une r ception ind sirable REFER TO INSTALLATION INSTRUCTIONS FOR THE CONTROL PANEL WITH WHICH THIS DEVICE IS USED FOR WARRANTY INFORMATION AND LIMITATIONS OF THE ENTIRE ALARM SYSTEM 2 Cor
6. in Delete a User Press 2 _ to select Delete a User e At Enter User No prompt enter the desired two digit number and press G amp G e The keypad will ding to confirm the User deletion and exit the Settings mode Assign Attributes Press G to select Assign Attr e At Enter User No screen enter the desired two digit user number and press _ The Assign Attributes menu appears 1 Authority Level 2 Access Group 3 User Partition 4 RF User Number 5 Pager On or Off Refer to the system User Guide for assigning the appropriate user settings in the Assign Attributes Menu 2 SINGLE BUTTON ARMING If desired the Arming Keys can be set for Single Button Arming by following prompts to store a valid user code in the keypad See the system User Guide for details on programming user codes Enabling Single Button Arming 1 Press and hold down the and G keys at the same time for 3 seconds The screen displays the keypad s address 2 Press to move to the USER CODE entry screen 3 Enter a valid four digit user code between 0000 9999 and press to save and continue Recommended Set a dedicated user code for this feature The user code must be entered for each keypad in the system where Single Button Arming is desired 4 Atthe Delete Devices screen press to decline and exit Disabling Single Button Arming 1 Press and hold down the and GO keys at the same time
7. porate Center Drive Suite 100 Honeywell P O Box 9040 Melville NY 11747 Copyright 2013 Honeywell International Inc www honeywell com security 800 115 7 13 Rev A

Download Pdf Manuals

image

Related Search

Related Contents

Manual de uso do fornecedor (download do pdf)  IN183 - カーメイト  Informazioni Prodotto  AVP-A1HD / AVC-A1HD 追加機能編 (11/1/2010)  ESPECIFICACIONES DE CONSTRUCCION ESPECIFICACIÓN No    DF 6115 E DF 6115 W DF 6116 E DF 6116 BX DF 6116 AX DE  Defort DSG-80N  Belkin 10.2'' Netbook Case  Eaton SENSOR-T1H1-10 temperature transmitter  