Home
B A C B A C
Contents
1. 180 SDN 25 30 SDN 35 45 65 CORD SET ELEK KABEL 20 WATER OUTLET WASSERABFLUSS G3 4 WATER INLET WASSEREINLAUF SDN 25 mm SDN 30 mm SDN 35 mm SDN 45 mm SDN 65 mm 334 377 377 485 485 454 552 552 572 572 597 637 637 721 816 GENERAL INFORMATION AND INSTALLATION A INTRODUCTION This manual provides the specifications and the step by step procedures fortheinstallation start up and operation maintenance and cleaning for the SIMAG SDN Series Icemakers The SIMAG SDN cubers are quality designed engineered and manufactured Their ice making systems are thoroughly tested providing the utmost in flexibility to fit the needs of a particular user NOTE Toretain the safety and performance built into this icemaker it is important that installation and maintenance be conducted in the manner outlined in this manual B UNPACKING AND INSPECTION 1 Call your authorized SIMAG Distributor or Dealer for proper installation 2 Visually inspect the exterior of the packing and skid Any severe damage noted should be reported to the delivering carrier and a concealed damage claim form filled in subjet to inspection of the contents with the carriers representative present 3 a Cutand remove the plastic strip securing the carton box to the ski
2. or a plumbing permit is required F FINAL CHECK LIST 1 Is the unit in a room where ambient temperatures are within a minimum of 10 C 50 F even in winter months 2 Is there at least a 15 cm 6 clearance around the unit for proper air circulation 3 Is the unit level IMPORTANT 4 Have all the electrical and plumbing connections been made and is the water supply shut off valve open 5 Has the voltage been tested and checked against the data plate rating 6 Has the water supply pressure been checked to ensure a water pressure of at least 1 bar 14 psi Open the shut off valve and verify the absence of water losses from the connections Page 3 7 Have the bolts holding the compressor down been checked to ensure that the compressor is snugly fitted onto the mounting pads 8 Check all refrigerant lines and conduit lines to guard against vibrations and possible failure 9 Have the bin liner and cabinet been wiped clean 10 Has the owner user been given the User Manual and been instructed on the importance of periodic maintenance checks 11 Has the Manufacturer s registration card been filled in properly Check for correct model and serial number against the serial plate and mail the registration card to the factory 12 Has the owner been given the name and the phone number of the authorized SIMAG Service Agency serving him G INSTALLATION PRACTICE Hand shut off valve Wat
3. 80 125 210 Criteria for selection of location include a Minimum room temperature 10 C 50 F and maximum room temperature 40 C 100 F b Water inlet temperatures minimum 5 C 40 F and maximum 40 C 100 F c Well ventilated location for air cooled models clean the air cooled condenser at frequent intervals d Service access adequate space must be left for all service connections through the rear of the ice maker A minimum clearance of 15 cm 6 must be left at the sides of the unit for routing cooling air drawn into and exhausted out of the compartment to maintain proper condensing operation of air cooled models NOTE With the unit in built in conditions the ice production is gradually reduced in respect to the levels shown in the graph up to a maximum of 10 at room temperatures higher than 32 C The daily ice making capacity is directly related to the condenser air inlet temperatu re water temperature and age ofthe machine To keep your SIMAG CUBER at peak perfor mance levels periodic maintenance checks must be carried out as indicated on this manual CAUTION Incorrect voltage supplied to the icemaker will void your parts replacement program 2 Level the Icemaker in both the left to right and front to rear directions by means of the adjustable legs D ELECTRICAL CONNECTIONS See data plate for current requirements to determine wire size to be used for e
4. d b Remove the packing nails securing the carton box to the skid c Cutopen the top of the carton and remove the polystyre protection sheet d Pull out the polystyre posts from the corners and then remove the carton 4 Remove the front and the rear panels of the unit and inspect for any concealed damage Notify carrier of your claim for the concealed damage as stated in step 2 above 5 Remove all internal support packing and masking tape 6 Check that refrigerant lines do not rub against or touch other lines or surfaces and that the fan blades move freely 7 Check that the compressor fits snugly onto all its mounting pads 8 See data plate on the rear side of the unit and check that local main voltage corresponds with the voltage specified on it Page 1 9 Remove the manufacturer s registration card from the inside of the User Manual and fill in all parts including Model and Serial Number taken from the data plate Forward the completed self addressed registration card to SIMAG factory C LOCATION AND LEVELLING WARNING This Ice Maker is designed for indoor installation only Extended periods of operation at temperature exceeding the following limitations will constitute misuse under the terms of the SIMAG Manufacturer s Limited Warranty resulting in LOSS of warranty coverage 1 Position the machine bin in the selected permanent location and tighten the four legs SDN 35 45 65 SD
5. e tubing supplied with the machine to the cold water supply line with regular plumbing fitting and a shut off valve installed in an accessible position between the water supply line and the unit If water contains a high level of impurities it is advisable to consider the installation of an appropriate water filter or conditioner WATER SUPPLY WATER COOLED MODELS SD 80 125 210 The water cooled versions of SIMAG Ice Makers require two separate inlet water supplies one for the water making the ice and the other for the water cooled condenser Connect the 3 4 GAS male fitting of the water inlet using the flexible tubing supplied with the unit to the cold water supply line with regular plumbing fitting and a shut off valve installed in an accessible position between the water supply line and the unit WATER DRAIN Connect the drain fitting with a plastic tube to an open trapped and vented drain When the drain is a long run allow 3 cm pitch per meter 1 4 pitch per foot On water cooled versions the water drain line from the condenser is internally connected with the drain fitting of the unit It is strongly recommended therefore to install a vertical open vent on unit drain line high point to ensure good draining and to direct the drain line to a trapped and vented floor drain receptacle NOTE The water supply and the water drain must be installed to conform with the local code In some case a licensed plumber and
6. er filter Water supply line flexible hose 3 4 GAS male fitting Vented drain Open trapped vented drain Drain fitting Main switch Power line OMNOAARWD 100 F WARNING This icemaker is not designed for outdoor installation and will not function in ambient temperatures below 10 C 50 F or above 40 C 100 F This icemaker will malfunction with water temperatures below 5 C 40 F or above 40 C
7. lectrical connections All SIMAG icemakers require a solid earth wire All SIMAG ice machines are supplied from the factory completely pre wired and require only electrical power connections to the wire cord provided at the rear of the unit Page 2 Make sure that the ice machine is connected to its own circuit and individually fused see data plate for fuse size The maximum allowable voltage variation should not exceed 10 and 10 of the data plate rating Low voltage can cause faulty functioning and may be responsible for serious damage to the overload switch and motor windings NOTE All external wiring should conform to national state and local standards and regulations Check voltage on the line and the ice maker s data plate before connecting the unit E WATER SUPPLY AND DRAIN CONNECTIONS GENERAL When choosing the water supply for the cuber consideration should be given to a Length of run b Water clarity and purity c Adequate water supply pressure Since water is the mostimportant single ingredient in producing ice you cannot emphasize too much the three items listed above Low water pressure below 1 bar may cause malfunction of the ice maker unit Water containing excessive minerals will tend to produce cloudy colored ice cubes plus scale build up on the interior parts of the water system WATER SUPPLY Connect the 3 4 GAS male of the water inlet fitting using the food grade flexibl