Home
        User manual
         Contents
1.    KRALGQFCUP    Ing  Aina Kenellovd  amp  Ing  Lo Revol    KRALueter 3          KRALgroup   N_a 20131207   ISC35all v2         KRALgFcup  cz  Oy    IS C 35 65LE MID  IS C 35 65LD MID   IS C 35 80LE MID  IS C 35 80LD MID    Electronic  4 wires  three phase kWh meter    with MID type test approval  with changes valid to  7 12 2013  Features and specifications are subject to change     USER MANUAL    KRALGFcCUPp   602 360 501 2    Ing  Alena Kurillovd  amp  Ing  Leos Rosol   281 970 988       Meinlinova 309 5 lt    info kralgroup cz  CZ 190 16 Praha 9   Kolod  je _http   www kralgroup cz       KRALgroup    A WARNING     Device installation and use must be carried out only by qualified staff     Switch off the voltage before device installation    The content and the technical specification of this User Manual are subject to  change without prior notice  They do not represent any contractual obligation   KEEP THIS INSTRUCTION MANUAL   CONTAINS  I A   EU DECLARATION  OF CONFORMITY    GENERAL DESCRIPTION   The three phase energy meter of series IS C 35 XX is electronic  fully operating  device for direct measurement and recording of active electric energy consump   tion in three phase electricity power distribution systems  The energy meter re   quires no additional auxiliary power supply and is equipped with an optical test  output  potential free electrical pulse output for transmission of electrical pulses  with a fixed time period and with LCD register for recording of the mea
2.   Metrology marking C    M12 0118  CE M12     Energy meters of series IS C 35 XX fully conform to DIN EN 50470 01 and DIN  EN 50470 3 standards  which are valid for energy meters and thereby meet the  requirements on features for energy meters for accuracy class B for direct con   nection of electric meters    This product complies with EU Directive No  93 68 EEC and complies with all  the articles of the EC Directive 89 336 EEC for  Electromagnetic Compatibility   with regard to standards EN 55 022   A1   A2 and EN 61 000 4 2   3   4   5   6     12    Energy meters design meets the following standards    EN 50470 1Electricity metering equipment  a c     Part 1  General requirements   tests and test conditions   Metering equipment  class indexesA  B and C    EN 50470 3Electricity metering equipment  a c     Part 3  Particular re   quirements   Static meters for active energy  class indexesA  B and C     Product name     Potential free pulse output fully complies with DIN EN 62053 31 for the impulse  to conform to the conditions of Class A or Class B  as well as the standard  DIN 43864  changed in the meantime  for pulse output of type  SO      Energy meter meets the requirements for verification according to DIN 43856 in  single tariff connection no  4600 or in double tariffs connec tion no  4702     Energy meter external dimensions corresponds to the built in devices of a 5 mo   dules  5 TE  size on DIN rail according to DIN 43880 stan dard    Installation of the energy mete
3.  1 5 mm  or in con   nection full copper wire with a maximum cross section 2 5 mm       Screw terminals for tariff control and pulse output terminal screws are rolled flat  head screw M2 5 for flat screwdriver size 0 6 x3 5  Tightening torque is approx    0 4 Nm max     METER DESIGN   Electronic parts and components inside the meter are covered with an insulating  varnish and thus are the most protected against climatic influences  The internal  power supply is provided via capacitive three phase power supply and ensures  meter operation even if only connected between phase and neutral as well as  between the phases without neutral  Internal consumption meter is low and is  mainly due to capacitive reactive energy  Self  heating done by ele  flow practically does not occur   Meter measuring is determined by the applied voltage level and the currei  passing through resistors which reduce the primary variables so that wt can be  processed electronically  This enables to measure very small values            KRALgroup  KRALGFcCUPp  420 602 360 502    http  Awww kralgroup cz  big  Alina Kuila  amp  Decl ace Rool  420 602 360 501 D lt  Info kralgroup cz O003TP 01     Meinlinova 309 CZ 190 16 Praha 9   Kolod  je    420 281 970 988  gt   akilrpremagas atlas cz                KRALGQFCUP    Ing  Abia Kenillovd  amp  Ing  La Hoc       KRALweter 3       Processing of measured values is performed in a special integrated circuit for  the measurement of energy consumption  which ensures a v
4. aha 9   Kolod  je       http   www kralgroup cz     lt  info kralgroup cz     lt     aklroremagas atlas cz                      KRAL       Group    Ing  Abia Kenillovd  amp  Ing  La Hoc    KRALwetor 3       NAMEPLATE DESCRIPTION  example                    Test output  Trademark Type designation  LED RL  The measured va   Symbols  Drehstromzahler lue  5 2 or 6 1    three phase KRAlwetex _ 18 c 35 65LE places  kWh  system Voltage  current     accuracy class frequency    standards 3 x 230 400V  0 25 5 65 A  50Hz LED    MXX AE EE pulses cons   compliance  o CE XXXX IR sev es ae tant and pulse    reverse run     ___    output  ning stop a V  robn       slo   rok v  roby  Standard EU conformity mark  type Number of connec   application approval MID  module B tion type    KRALGQFZCUP  Ing  Alis Kurillov    amp  Ing  aie Rosol     Meinlinova 309 CZ 190 16 Praha 9   Kolod  je                 420 602 360 502   420 602 360 501        420 281 970 988       TECHNICAL DATA    Type test approval number    Type of connection to the electricity  network    Reference voltage and frequency    Number of places  see meter     Pulse constant  optical  see meter  imprint     Pulse constant  electrical  see meter  imprint     Number of pulses   clock period  accuracy    Extended operating voltage range   conditions    Internal power consumption in voltage  circuit    Apparent power consumption in current  circuit    Actual starting current  three  single   phase    Higher harmonic frequencies accep
5. ch always one is active  The active tariff is shown on the LCD in  the bottom right  which currently measures the energy consumption  A flashing  displayed symbol  T1  represents the current registration in the energy tariff 1   while LCD display  this counter displays  A flashing displayed symbol  T2   represents the current registration in the energy tariff 2  while LCD display  this  counter displays  To display the tariff that is not displayed  use the key    call         Aufruf      which is necessary to press for less than 2 seconds  The display  returns automatically in the currently registered active tariff within 10 seconds  after pressing the key    call        Aufruf     and or once measured consumption  increases the value of register by one number above  A permanently displayed   non flashing  symbol  T1  indicates the instant status of electricity consumption  in tariff 1  as well as permanently displayed  non flashing  symbol  T2  indicates  the instant status of electricity consumption in tariff 2        Mode 6 1  shows Tariff 1 register    Mode 6 1  shows Tariff 2 register    The double tariffs energy meter design enables the settings of register to the  higher resolution and with the possibility to view the registered in the non active  tariff  After  short or long  pressing of the key    call        Aufruf     occurs permanent   non flashing  symbol    T1    on the LCD or alternatively symbol    T2     tariffs do not  appear together  which means that energ
6. ery good measure   ment properties of the meter  Calculation and control functions are performed in  a programmable microchips from which data are transferred via an optical test  port  RL   LED   and electrical output of type  SO  and to meter display    Electric pulse output is potential free and galvanic separated from current and  voltage inputs and outputs  Control switch tariff consumption is provided by po   wer supply voltage  within the parameters limit  between phase and neutral  with  the use of this control voltage has no retroactive effect on the functional charac   teristics of the meter or measuring    Double tariff meters are equipped by additional device to interrupt current flow  and voltage and potential free pulse output for controlling the switching rate   This auxiliary device is activated during operation beyond the values limit of the  voltage and current tariff switching off functions  This device does not have any  retroactive effect on the functional characteristics of the meter or measuring     METER FUNCTIONS   BASIC METER FUNCTIONS   The meter has no externally accessible adjustment or settings    Red flashes LED test output depends on the power consumption based on con   necting active energy load on meter terminals  Slowly flashing LEDs corres   ponds to a small consumption and quick to a large electricity consumption    In case of continuous LED lighting  the meter is either in standstill and or with ac   tivated reverse running stop  both of 
7. h no maintenance and without necessity for  constant monitoring  Repairs and adjustments made by the user are not expec   ted  Opening the electricity meter made by the user is not necessary and always  leads to instrument destruction  To measure energy consumption  which re   quires device verification to the billing instrument is assumed  that after the veri   fication any instrument opening brings the lost verification revocation and the  instrument must be re verified  Unauthorised encroachment on electricity meter  or its any modification  change or technical improvement also terminate verifica   tion and manufacturer s liability for instrument defects  The electricity meters   series IS  C     35 65 80 ME     LE     LD may be used only as determined to en   sure their precise function and to prevent any damage  personal injury and other  dangers associated with their improper use     FRONT VIEW AND NAME PLATE  Energy meter example                                                                 METER HOUSING AND INDICATORS    Tariffs control terminals    Potential free  output  terminals SO              Sealing shoe    Mechanical  or LCD    coe Sealing shoe  Indicator  LED  Hinged  Meter terminal cover  nameplate          Sealing shoe    Sealing shoe       Hinged terminal cover  with wiring diagram       KRALgroup    O03TP 02     420 602 360 502   420 602 360 501     420 281 970 988    KRALGFcCUPp  Ing  Alis Kurillov    amp  Ing  Deez Rool     Meinlinova 309 CZ 190 16 Pr
8. nt and voltage L1__ wire phase 1  230 V  _____    measured wire phase 1  cn D 20 O     Terminal 4 _____input current and voltage L2 _ wire phase 2  230 V  _____    measured wire phase 2  fu oe      Terminal 7 ____input current and voltage L3 _ wire phase 3  230 V  _____    measured wire phase 3  fom C 20 O  Terminal 11 _________ output voltage ______ neutral of the supply  0 V     tariff signal input passive control input  ermina TS  only with IS C LD   230V  oo    tariff signal input passive control input  ermina 19  only with IS C LD   230V  o    potential free passive  Terminal 20 pulse output st pulse output  24V     2 potential free passive  Terminal 21 pulse output SO pulse output  24 V           tL1 4L1  tL2 4L2 tL3 4L3 tN        TERMINALS   Meter terminals for connecting current and voltage are accessible in the lower  part of the meter housing through approximately rectangular holes of 6 5 mm x 7  mm size  either for connection of twisted wires slipped into copper tubes with  a maximum cross section up to 16 mm    or solid copper connections wire with  a maximum cross section of 25 mm       Screw terminals for connecting current and voltage are head rolled  thread M6  designed for screwdriver No   PH2  Tightening torque is approx   3 0 Nm max   Tariff control and pulse SO output terminals are designed approximately with a  circular hole of 3 mm in diameter for connecting the coiled wire  area of cable  in   serted into the copper tubes with a maximum cross section of
9. power consumption is high  it them more LED flashes  can occur in one second  After reaching the electricity consumption of 0 1 kilo   watt hours  0 1 kWh   100 Wh  the meter register  in the active tariff  increases  the digit by one number above  The control signal must be connected to termi   nals no  13 and 15 in case of energy meter in double tariffs design in order to  execute the tariff switching  The active tariff can be seen only if the energy meter  is not in standstill  no electricity consumption is measured   however the active  tariff display has priority and occurs automatically after a short time    The terminal covers must be closed after energy meter installation into the net   work in order to increase the protection against contact with the electricity  In ca   se of closed terminal covers it is possible to seal them by standard seal and wire  and thus make them by higher security against unauthorised opening     SUPPORTING INFORMATION   The electricity meters  series IS  C     35 65 80 ME    LE     LD are measuring in   struments for electric energy metering and may be used only for this purpose for  which  they are designed  tested and reliable  They are installation devices and  are not designed for portable  mobile  applications  Connection method  opera   ting  storage and environmental conditions are listed in this manual and in the  case of installation must be strictly observed  Electricity meters work within their  limit of technical parameters wit
10. rs is designed for mounting on a standard DIN rail  35 mm wide according to DIN EN 50022 standard    The electric protection class of the energy meters with terminal covers corres   ponds to IP51 according to DIN EN 60529 standard    Dimensions of electrical connections and tightening torque of the terminal  screws electricity are given in DIN EN 60999 1 standard    The power force caused by cables and lead wires are determined according to  DIN VDE 0298 4 standard     V Praze 5 05 2009    KRALOQFCUP    Ing  uber KO  amp  Ing  J DBR IREI    Your partner for measuring the energy    DIN RAIL MOUNTED kWh METERS   RE CONDITIONED kWh METER   PRE PAZMENT kWh METERS   CREDIT CARDS kWh METERS   GSM OPERATED kWh METERS   SPECIAL kWh METERS   OTHERS FOR THE MEASUREMENT OF EL  ENERGY   CURRENT TRANSFORMERS   MEASURING POWER IN HARBORS AND ANCHORAGE SHIP   MARINAS    MEASURING POWER IN THE CAMP  IN TRADE FAIR   EXHIBITION  BUSINESS  COMMERCIAL AND    petent authority  ADMINISTRATIVE CENTERS  ENERGY MANAGEMENT SYSTEMS ye   i  M Bus  PLC  GSM  RS 485  EIB  INSTA BUS      Our advice is for You with pleasure     KRALgroup  KRALGFCUPp  420 602 360 502   http   www kralgroup cz  Ing  Alena Kurillove  amp  Ing  Leos Rosol  420 602 360 501 DK  info kralgroup cz 003TP 04     Meinlinova 309 CZ 190 16 Praha 9   Kolod  je    420 281 970 988 S  aklroremagas atlas cz i                
11. ssive     ie T1 2    I EE     i al   lelz  ol h lol24    13 15   SO output AC 230V  DC 24V    4600                                                                                                                             4 wire direct connection 3x 230 400V  4600  4702  A Passive  ka    lal  slat lel7  ol fa  2024  _  1345   SO output AC 230V  DC 24V  L1 L1  L2 L2  L3 L3    3 wire direct connection 3x 230V    4600             3 wire direct connection 3x 400V    DIMENSIONS  mm              Drehstromzahler  IS C 35 65LE           92  44 5              3 x 230 400V  0 25 5 65 A  50Hz  DE 08 M1003 PTB003 Schaltung 4600  DIN 43856   V1 4  V  robn       slo   rok v  roby                                           I I l 1 1 l 1    PLETE    6X 12 5                                                    WASTE DISPOSAL     This product may not be  at the end of its useful life   disposed of with normal house hold waste but must  be returned to a col lection point for recycling of  electronic equipment  Please check with your  dealer or local authorities for disposal of the com           EU DECLARATION OF CONFORMITY     THREE PHASE STATIC WATT HOUR METER FOR  TARIFF METERING OF ACTI VE ENERGY    Type designation  IS C 35 65     80 ME     LE    LD    EC Type test certificate  DE 08 MI003 PTB003   acc  to direction MID EC no    2004 22 EG  module B     Number and address of notified person    Modul B  0102     PTB  Physikalisch Technische Budesanstalt  Bundesallee 100  D 38116 BRAUNSCHWEIG  
12. sured  energy consumption  The meter is designed for use in low voltage distribution  system of electricity power distributors  External housing with size of 5 modules   5 TE  on standard DIN rail can be easily installed in small electric switchboards  to be direct connected for measuring the energy consumption up to 65  resp   80A  IS C 35 XX meets the requirements of EN 50471 1 2006 and EN 50470   3 2006 standards in accuracy class   B   With type test approval  MID Module B   No   DE 08 MI003 PTBO03 valid up to 22 06 2013 the series IS C 35 XX can be  used for billing metering of electricity consumption     METER ASSEMBLY AND INSTALLATION   Assembly and installation of energy meters is arbitrary and do not effect on ac   curacy or function for their usage  Nevertheless  as the standard the energy me   ters should be mounted vertically on horizontal fixed DIN rail with a width of 35  mm  Installation on the meter board according to DIN 43853 standard is not pos   sible without using an adapter     METER HOUSING AND TERMINAL COVERS   Meter terminal and housing covers are made of a polycarbonate blend conta   ining from about 6  sodium proportion of glass fibers  The housing parts are  locked and bolted in the manufacturing process  Window on the counter meter is             made of clear polycarbonate and is captive glued to the upper part of the meter   For the dimensions please see  Data  section     CONNECTIONS  Terminal No   Description Connection  Jerminal 1 input curre
13. ted    Size of connection wires for terminals 1  up to 11    D lt  Info kralgroup cz     lt        http   www kralgroup cz    akiroremagas Qatlas cz    DE 07 MI003 PTB003    No  4600 or 4702 according  to DIN EN 43856 standard    Un   3x230 400  1   10       MoO EA o  Ist   0 02A  Imin   0 25A  ltr   0 5A    Iref   SA  Imax    65 80A    class B    1      alternatively class A     2      6 digits   full places for kWh and  1 decimal place  0 1 x kWh     Standard 1000 imp kWh  1 Wh imp     At least one pulse with an integration  time of 5 seconds    Potential free according to DIN  EN 62053 31 standard class A and B    Umax   30VDC  Imax   30mA    tmin   30ms  reverse polarity protection    180V up to 265V  three phase voltage   clockwise    0 25   5 80 A  0 25   5 65 A   0 5   10 60 A  0 5   10 80 A    at Iref  lt  0 1VA  at Imax  lt  2 5VA       18 mA per phase at Un  fn and cos  1    up to 4 kHz    3K6   25  C up to  55  C   indoor installation    annually average  lt  75    short term 95   non condensing    Electrical protection class Il   protection insulation    Design size 2  depth 55 mm  5 units on  DIN rail  5 TE     on DIN rail according to EN DIN 50022  standard  position independent    Polycarbonate blended with 6   of the  fibers  gt PC GF6 lt     2 5 mm   max   flexible wire 16 mm      solid wire 25 mm        KRALgroup       O03TP 03       KRALGQFCUP    Ing  Alna Kuslbova  amp  Ing  Lax RKosol       KRA Lulin  3       SELECTED CONNECTION DIAGRAMS IN EXAMPLES    Pa
14. which means  that no energy is taken on  meter output and or meter detects improper energy flow and is not connected  according to wiring diagram  reversed terminal connection for input and output  wires   In both cases  the counter does not emit electrical pulses and the counter  does not register energy    Electric pulse output terminal 20 and terminal 21 are of the same tact as a red  test diode  These pulses are electrically passive   comparable to mechanical  contact   and must be processed converter by A D operating DC voltage of 27 V  and or a current of 27 mA max  At standstill of the meter  the electrical output con   tact remains open and does give at this time no impulses    The meter register records the energy flow measured in value of kilowatt hours   kWh   In case of mechanical register   the last digit  marked by red color  re   cords consumption 0 1 times the kilowatt hours  0 1 kWh   100 Wh   In case of  LCD register the displayed number after the decimal point records 0 1 times the  consumption of kilowatt hours  0 1 kWh   100 Wh     According to the meter pulse constant  1000 pulses kWh   1 Wh pulse  the LED  flashes 100 times  until the register changes for one higher number     DOUBLE TARIFFS DESIGN   Energy meter in double tariffs execution  only type IS C     LD with LCD register   has additionally terminals no  13 and 15 to control the tariff switching  which  allows to measure the electricity consumption in the two separate energy  registers from whi
15. y meter is in standstill  without energy  consumption of its output   the red LED    RL    lights permanently on the energy  meter at the same time  The return to the normal display  6 1 points  is done by  pressing the  call      Aufruf     key for more than two seconds  or automatically  after 5 minutes from the time of last key press and or automatically after 5  seconds after displaying of non active tariff together with displaying of actual  active tariff        Mode 5 2  shows Tariff 1 register    Mode 5 2  shows Tariff 2 register    COMMISSIONING   The electrical wiring and standards for energy meter installation must be strictly  kept  Work on the electrical equipment may only be performed by the experien   ced specialist  After energy meter connecting on voltage the red LED    RL    starts  and remains light continuously  without flashing   which is located on the front  cover of the energy meter cover  Energy meter register and pulse output will re   main inactive  After connecting an electric appliance on the side of power output  the energy meter starts to measure the electricity consumption  in case of its  proper electrical wiring  and register the consumed energy  At the same time the  red LED  which continuously lighted before connecting the appliance  starts pe   riodically flashing at the intensity depending on the value of the electricity flow  If  the power consumption is low  it may take up to several minutes between two fla   shes of the red LED  if the 
    