User Manual ADAM-3600-C2G

image

Contents

1. iii 26 Figure 4 8 Editing TCP Information sse see ee eee ee eee 26 Figure 4 9 Adding and Deleting a TCP Meter 21 Figure 4 10Configuring a TCP Meters 1 0 21 Figure 4 11 Adding and Editing TCP Ports 28 Figure 4 12Adding a New ZigBee Port 29 Figure 4 13Adding a ZigBee Meter i ii 29 Figure 4 14ZigBee Meter I O Configuration 30 Figure 4 15User Tag Configuration 30 4 2 3 Protocol Service Configuration eee eee e ee e ee eee 31 Figure 4 16Adding I O Tags to the Modbus Address List 31 Figure 4 17 Adding I O Tag Information 32 Figure 4 18WebAccess wherelAM 32 4 2 4 System Settings ss 33 Figure 4 19On board I O Settings sse eee eee 33 Figure 4 20Expansion I O Settings 34 Figure 4 21 Wired Network Settings 35 Figure 4 22 Wireless Network Settings 35 Figure 4 23GPRS Settings e eee eee eee eee 36 Figure 4 24GPRS Script Setting iene 36 Project Deployment 36 4 3 1 Device Identification 37 Figure 4 25ldentification for Connected RTU Devices 37 4 3 2 Project Download sss esse eee 37 Figure 4 26Project Download sese eee 37 4 3 3 Password Settings 38 Figure 4 27 Password Information 38 Figur
2. 15 3 2 3 Expansion Input Output Module Installation 15 Figure 3 9 Expansion Input Output Module Installation 15 Figure 3 10Expansion Input Output Module Installation 15 3 2 4 Writeable Label 16 Figure 3 11Writeable Label 16 325 QU Card Installation au een 16 Figure 3 12Card Installation 16 3 2 6 SIM Card Installation 17 Figure 3 13SIM Card Installation 17 Jumper Switch Settings nenn nenn ennnnenennenennenennn 18 39 1 DIP SWICN Settings une 18 Figure 3 14DIP Switch Setting seem 18 3 32 JUMPET SENGS eide 19 Figure 3 15Jumper Settings 19 V ADAM 3600 Series User Manual Chapter 4 4 1 4 2 4 3 Appendix A A 1 Appendix B B 1 Advantech IRTU Studio 21 IRTU Studi o een 22 Using iRTU Studio for Configuration and Management 22 4 2 1 Project Initialization anne nenn nennen 22 Figure 4 1 Creating a new project eee ee eee 22 Figure 4 2 Adding Devices and Editing 23 Figure 4 3 Copying Devices ereta 23 Figure 4 4 Deleting Devices erram 24 4 2 2 Configuring the Data Center and Link Tag with IO 24 Figure 4 5 Configuring Onboard W O eee eee 24 Figure 4 6 Adding COM port 25 Figure 4 7 Adding a COM meter
3. is the address for client to access the tag data BG Project Help ECA Em a gt L x Ale Eg Close Save Device Password Project Search Setting act Configuration EJ COMI RTU 1 M Modbus Server RTU 1 x Oil pilot plant RTU 18 1 Modbus Server 15 Select Tag x Apply Cancel Chan Data Center tg 10 Tag a K 0 r E Device ID 1 pa BoardIO M Modbus Server e Tempi ke System Modbus TCP RTU 2 2 T E Data Center Port Number Electrical Paremeter Table Service Max Users Current i 3 7 ZigBee System Idle Time s gt Wirele gt Displacement 2 89 COMI 2 Select IO taa Temperature sensor 1 COM1 TEMP1 u COM1_TEMP2 tg User Tag Tag Name Tag Type Local Tagi Data Type Displacement AI Ea System Tag Unsigned 16 bit integer amp Double click to edit Cho Bu a as CU NT TIM 1 Double click here EGYS CPII FREO Figure 4 16 Adding I O Tags to the Modbus Address List 31 ADAM 3600 Series User Manual HG Advantech iRTU Studio Em Project Help Ci Aw p a E Close Save Device Password Project Search Setting act Configuration COM1 RTU 1 M Modbus Server RTU 1 x Oil pilot plant RTU 144 Modbus Server Apply Cancel Chan Y E Data Center 3 8 Service Device ID 1 M Modbus Server TS System Modbus TCP Modbus RTU RTU 2 2 i EE Data Center Port Number Port T Service Max Users Baud Rate aK System Idle Time s Data Bit Stop Bit Parity Tag Name Tag Type Address Modbus Address Data Ty
4. User Manual ADAM 3600 C2G IRTU User s Manual AD ANTECH Enabling an Intelligent Planet Copyright The documentation and the software included with this product are copyrighted 2015 by Advantech Co Ltd All rights are reserved Advantech Co Ltd reserves the right to make improvements in the products described in this manual at any time without notice No part of this manual may be reproduced copied translated or transmitted in any form or by any means without the prior written permission of Advantech Co Ltd Information provided in this manual is intended to be accurate and reliable How ever Advantech Co Ltd assumes no responsibility for its use nor for any infringe ments of the rights of third parties which may result from its use Acknowledgements ADAM is a trademark of Advantech Co Ltd IBM and PC are trademarks of International Business Machines Corporation All other product names or trademarks are properties of their respective owners Product Warranty 2 years Advantech warrants to you the original purchaser that each of its products will be free from defects in materials and workmanship for two years from the date of pur chase This warranty does not apply to any products which have been repaired or altered by persons other than repair personnel authorized by Advantech or which have been subject to misuse abuse accident or improper installation Advantech assumes no liability under the terms o
5. 1 1 New Meter gt Apply Cancel Chan s Data Center YO 2 General Information 3 After editing click Apply 87 COMI 1 Right click EI COM2 Name Wireless Dynamometer coma Select Add ADAM 3600 Series User Manual 7 Double click the I O Tag item to edit the tag to map with the data from Zigbee wireless meter q Project Help Ci Aw p a E Close Save Project Advantech iRTU Studio Device Search Password Setting EY COMI RTU 1 I O Tag Name act Configuration tos IO Tag RTU 1 Wireless Dynamometer x 2 Click Add o Oil pilot plant RTU 1 1 B Data Center UO 0 69 COM1 ED COM2 ED COM3 A A TCP 2 25 ZigBee miniPCle USB EE Wireless Dynamometer Data Type Address 00001 Conversion Type Scale Type Unsigned Integer Description gt Displacement Analog No Scale n Apply Cancel Chan J 3 Edit Tag basic information 7 EF Basic El Advanced 4 Set scalina type 5 After editing click Apply 25 System Tag 1 Double Eg User Tag lick IO Name Displacement ScalingType No Scale The tag information will be E clic f lt 1 2 Service Dane rer E E listed in the list J Lo System Tag RTU 2 2 Conversion Unsigned Integer y Hm Data Center Address 00001 Saale Y Service i Start Bit Bias 2 System 0 Length bit 16 Span High Initial Value 0 Span Low Description Clamp Clamp to low Clamp to high K Clamp to zero Figure 4 14 Zi
6. Delete Let Sy L Copy iCDManager Figure 4 3 Copying Devices 23 ADAM 3600 Series User Manual 4 2 1 4 Deleting Devices Users can right click on the device name and choose delete to delete a device in the project Project Configuration g g oil pilot plant De o se at Delete E B Sy E Copy RTU 1 Z CDManager l Data Center H Service ke System ER Figure 4 4 Deleting Devices 4 2 2 Configuring the Data Center and Link Tag with I O After adding a device there will be an item Data Center under the added device It is a place for user to manage data acquisition which is an important functionality for a RTU Through this interface user can manage all the ADAM 3600 resources which are able to fetch data from the field site The ADAM 3600 can support many interfaces for data acquisition include on board I O expansion I O serial device I O Ethernet device IO and Wireless Zigbee device l O All these above I Os can be configured as a tag by using the RTU Studio Beside the real I O tags user can also build some user tags which is with specific engineering purpose for management under the IRTU Studio 4 2 2 1 OnBoard I O Configuration ADAM 3600 is equipped with 8 ch Al 8 ch DI and 4 ch DO on the device user can map the real input signals to the IO tag through following instructions Cd BG Advantech iRTU Studio Ja Lx Es Project Help AS 69 BT ms Close Save De
7. Logic Control included RTU F gt ss CPU G gt Oil amp Gas 1 gt Cortex M4 W gt Water 2 gt CortexAB P gt Pipe Monitoring Figure A 1 ADAM 3600 Naming Rules Examples ADAM 3600 C2GL1AE Cortex A8 IRTU for Oil amp Gas C Series ADAM 3600 A1FNOAE Cortex M4 Remote IO for Facility Monitoring A Series ADAM 3600 Series User Manual 40 Appendix B Interface Definition B 1 Interface Definitions B 1 1 Communication Ports B 1 1 1 COM 1 RS 232 RS 485 m Connection DB 9 m Baud rate 1200 115 2k bps S RS232 signals RxD TxD GND RTS CTS E RS485 signals DATA DATA PIN RS 2328ignal e o me e CE 9 me RS 485 Signal B 1 1 2 COM 2 amp COM3 RS 485 m Connection Terminal Block E Baud rate 1200 921 6k bps E RS 485 signals DATA DATA Communication Isolation 2000Vpc RS 485 Signal DATAS DATAS ADAM 3600 Series User Manual 42 B 1 1 3 USB Port E Connection USB 2 0 1800 connect m USB signals Vcc Data Data GND PIN USB Signal B 1 1 4 LAN1 and LAN2 Ethernet Port m Connection RJ 45 Base T 1800 connect m Transfer rate 10 100Mbps m LAN signals TD TD RD RD 43 ADAM 3600 Series User Manual B 1 2 I O Interface Definition ADANI 3600 10 LED 00000000 I FAR IL comes 00000000 ADAM 3600 Series User Manual 44 45 ADAM 3600 Series User Manual AD ANTECH Enabling an Intelligent Planet www advantech com Please verify specificatio
8. Normal AIS 10V 50Hz DI5 Normal A AI6 10V 50Hz DI6 Normal N AI7 10V 50Hz y DU Normal Figure 4 19 On board I O Settings 33 ADAM 3600 Series User Manual While configuring the expansion module please click to select the target expansion slot first and select the module from the draw down list Then configure the related setting by click and select from the related column please refer to the figure below HG Advantech iRTU Studio e Project Help A a P E e a L do 3 H y Close Save Device Password Project Search Setting act Configuration EY COMI RTU 1 1 0 Setting RTU 1 x 3 After setting click Apply Oil pilot plant RTU 1 1 I O Setting Cancel Chan H E Data Center 1 Select extended module slot Service gt System 28 Network Setting RTU 2 2 Data Center 0 5 Service 3 8 System Slot1 Slot2 Slot3 Slot4 2 Click here select s added extended xtension Slot1 a0am 3617 Null module Type Name Range ADAM 3617 Time Type Name Mode ADAM 3651 Am 10V ADAM 3656 An 10V SOAT IO_AI AD 10V 50Hz r AB 10V 50Hz x Figure 4 20 Expansion I O Settings Click the button Calibration to execute the calibration function for the analogue input chan nel on board User has to provide the precious source for the zero and span calibration User only need to calibrate the channel 0 the related parameter will apply to all other channels automatically Please follow the instruct
9. and select Add Port 2 Inthe Type field of New Port page select Serial and input the related parameters for the serial port 3 Click button Apply the port will be created on the left hand side tree view under the Data Center item S HG Advantech iRTU Studio 2 il x Ely Project Help a 7 E a 2 Ao E Close Save Device Password Project Search Setting Project Configuration New Port RTU 1 x lt 2 Edit port information 2 58 oil pilot plant 2 Right click 4 After editiong gt EB RTU 18 1 New Port AE Eee Cancel Change Data Center k click Apply um Data Center 7 8 1 0 select Add 4 General Information fa TOP Port X ZigBee miniPCIe USB Type Serial Scan Time ms 1000 ti System Tag EE Serial 3 serial port Time Out ms 3000 I tg User Tag Bee XBee 1 2 Service gt Retry Count 3 2 9 System Auto Recover Time s 19 RTU 2 2 fia Data Center Serial Port Setting 4 Service System Port COM1 Baud Rate 9600 v Parity None Data Bit 8 v RTS False Stop Bit 1 v DTR False Figure 4 6 Adding COM port 25 ADAM 3600 Series User Manual 4 Right click the COMx item created on the previous step and select Add Meter to add meter 5 Inthe New Meter page type in the name and related parameters and click Apply to add meter While the meter added there is a new item I O Tag below the meter click the in front of the CO
10. can be converted instantly within the different communication protocols And pro vides the IEC 61131 3 standard amp C C library for the customer to develop pro grams This lets users develop programmable logic control in the most convenient way ADAM 3600 Series User Manual 4 2 2 2 2 1 2 2 1 1 NodelD as identification facilitate remote batch configuration ADAM 3600 has a six bit DIP switch on board which can be identification for 64 devices on the field Through an ordinary cable it could download configuration doc uments into RTU devices with a maximum of 64 and customers could find out the sources of faults through ID codes when variations encountered in the performance of RTU Intelligent communication condition monitoring software iCDManager Communication is the key function of RTU applications RTU hardware can monitor the health status of the hardware communication Users can use the intelligent algo rithm to identify the health status of communications lines remotely monitor the com munication quality through the network in group mode conduct the maintenance in advance so as to avoid emergency repair caused by temporary failure ADAM 3600 C2G Specification ADAM 3600 C2G Specification of Main Unit System Specifications RAW fonr Wireless Interface 2 x Mini PCle 1x Half Size 1 x Full Size Serial Signal Wi Fi SD Card Standard SD For Data Storage Micro SD 1GB For OS Sto
11. click e com2 TCP select Name Electrical Paremeter Table Add Meter Meter Type Modicon Y X zig 14 Edit Unit Number 1 Hi Sys de Add Meter 7 Ed Us 3 Delete Description Electrical Paremeter Table E Service TRS System RTU 2 2 Data Center i TCP IP Service Syst pen IP Address 0 0 0 0 Port Number 0 Sk Extention Properties Device Address if other than Unit Number N v Use UDP Figure 4 9 Adding and Deleting a TCP Meter 5 Double click the I O Tag item to edit the tag to map with the data from Ethernet Ha Advantech iRTU Studio Le Project Help A a E a 4 oo g Ja Close Save Device Password Project Search Setting act Configuration EJ COM1 RTU 1 Electrical Paremeter Table RTU 1 av IO Tag RTU 1 Electrical Paremeter Table x 2 Click Add 7 Oil pilot plant EB RTU 14 1 I O Tag gt ri sa Data Center 4 28 1 0 Name Data Type Address Conversion Type Scale Type Description H E COM1 Current Analog 00001 Unsigned Integer No Scale EY COM2 ie com3 1 Double click iil TOP IO Tag 2 51 Electrical Paremeter Ta gt Apply Cancel Chan I tom IO Tag e X ZigBee miniPCle USB SF Basic U 3 Add Tag basic information El Advanced 4 After editing click Apply as System Tag EB User Tag Name aan ScalingType No Scale The tag information will be amp Service Data Type Analog v Formula listed in the list 2 System EB RTU 2 2 Conversion Unsigned Integer y Data Center Ad
12. old and new password respectively and then confirm the new password 3 Back to the General Information of the RTU device edit password to ensure it fit the new password Please note the Project download will not work if the password does not match EG TI Project Help SR a j FETE Aa 1 lt 6 Ba EB 1 Click Password Close Save Device Project Export To Password Setting j Project Search Download SD Card Setting act Configuration RTU1 x Oil pilot plant MM RTU 1 1 RTU 1 i 2 In the dialog box enter the new password and Ff General Information verify it Name RTU 1 Y Password Setting Device Type Device The old password will be set al Password Old Password the new password p Indentity Node ID New Password Verify Password esosos Node ID 1 IP Address Description Oil pilot test 1 device Figure 4 28 Password Settings ADAM 3600 Series User Manual 38 Appendix A ADAM 3600 Naming Rules A 1 ADAM 3600 Naming Rules The ADAM 3600 includes two types of products that are ADAM 3600 A1F and ADAM 3600 C2G which shows a difference as far as their design and features In this Manual we focus on the introductions of ADAM 3600 C2G ADAM 3600 C 2 GL1 AE sn RoHS l PP euer Revision Control RTU Brand Name E A B Z Fixed es Operation System 2 a NO None 05 Intelligent Dummy E et A gt Data Acquisition Remote I0 EEE Type for Vertical C
13. 5 sample KR ariasi Network Setting Apply Cancel Change Data Center 4 1 0 in Wired Network Setting ED COMI E COM2 LAN LAN1 EY COM3 IPv4 IPv6 fn TCP F ZigBee miniPCle USB M DHG Y DHCP H System Tag Eg User Tag E Service M Modbus Server 2 System 1 0 Setting Network Setting A Wi Fi Setting Enable Network SSID Security ull GPRS Setting 2 click Connect connect EWM C109F601E Advantech cmnt v EWn ciosrouie advantecncmt 4 choose the GPRS type EWM C109F601E Advantech unicom other Figure 4 23 GPRS Settings If there are different communicated modes applied Users should make scripts ull GPRS Setting MN Y Connect P E 000000 Di Main Script Connect Script Disconnect Script Figure 4 24 GPRS Script Setting 4 3 Project Deployment This section will introduce the steps to download the configured project to the related RTU devices Users can one click to download the project to many RTU devices through the NodelD identification ADAM 3600 Series User Manual 36 4 3 1 Device Identification Before we start to download the configuration to the RTU device users have to adjust the connected RTUs to be with the correct NodelD as project required The Device Search will help user to explore all the RTU devices which the NodelD is men tioned in the configured project After the search utility will feedback the IP address of the RTUs and show the status as on line If the NodelD
14. Al calibration for on onboard IO and Expansion IO m With regard to network communications user can complete the settings for Ethernet Wi Fi 3G and GPRS via iRTU Studio m ADAM 3600 provides Modbus RTU Modbus TCP and DNP3 0 servers and customers can flexibly choose protocol services according to their own needs m Advantech iRTU Studio Support remote monitoring of communication status of serial ports and Ethernet ports Advantech iRTU Studio can be downloaded from Advantech support website http support advantech com Using IRTU Studio for Configuration and Management Project Initialization Project Initialization can be achieved while users start IRTU software and step by step com plete Create Project gt Right click to Add Device gt Right click to Copy for large num ber ADAM 3600 configuration Creating a new project Start IRTU Studio software click create project button under the taskbar Project and you will find the dialog box as follows what you need to do is to input the project name descrip tion and select the storage directory then click OK button Te Project x Name Oil pilot plant Author Ying Liu Path C Users ying liu Documents Advantech iRTU Studio Project Description Oil pilot test project site deployment OK Cancel Figure 4 1 Creating a new project ADAM 3600 Series User Manual 22 4 2 1 2 Adding Devices and Editing a Project After completing the creation of the ne
15. Logic 1 11 30Vpc Rated Voltage 12 24 Voc Rated Input Current gt 5mA Q 12Vnc gt 10MA 24Vpc Input Filter Programmable Default 3ms Pulse Input Frequency 150HZ 2 2 2 5 ADAM 3656 8 ch DO PO chem Po gt mr Pulse Output Frequency Isolation Voltage 2000 Voc 2 2 2 6 ADAM 3664 4 ch RO Isolation Voltage 2000 Voc 2 3 LED Indicators 14 m m mm d an mm mm om om 6000066008 33322233 2 ur La vir a sr IIT x DIO 1 2 3 4 5 6 7 comem Al 0 0 1 1 2 2 3 3 LAG 1 gt AD ANTECH ADAM 3600 am a iu ae aS ss mn m mm gt gt CALLI e 4 pg ts vA N aby 4 m E m nu ha m En L E baee 5 6 0 DO 002 GND DOG DO DOZ DE GNO Deo pet 002 oo 1 D02 DOS 959 MNVAV System LED Status BI ZZ PR Ge 2 sue pro DO 0 1 2 3 4 4 55 6 6 747 e AN a CO I MI ISIC JUGSGTGES VG o OO Figure 2 1 LED Indicator ADAM 3600 Series User Manual 8 2 3 1 System LED Function Description Light on Device powered Blinking Normal Operation control by user s program or Softlogic ERR Red Light on System failure control by user s program or Softlogic BAT Red Light on battery lower than 5V PROG Control by user s program 2 3 2 Digital Input Output Indicator LED DIO Green Light on the channel is activated by input signal De Green DOO Green Light on the chann
16. M port and meter to unfold it BG Advantech iRTU Studio Project Help Ea P E a a A x o ES Close Save Device Password Project Search Setting ct Configuration E COMI RTU 1 EB New Meter RTU 14 x lt 2 Edit new meter information Oil pilot plant 3 After editing tast 1 Right click New Meter A 9 aoo loan click A E 5 Data Center COMI select pply 4 25 YO Add Meter T General Information pa Edit e com 2 ED COM de Add Meter 2 th TCP Delete Meter Type Modicon SK ZigBee miniPCle USB Unit Number t 3 System Tag Name Temperature sensor 1 ta 1 Temperature sensor tg User Tag Description p 2 Service e System RTU 2 2 Data Center 3 12 Service 3 Extention Properties amp System Use ASCII Protocol 0 Packet Delay ms 0 Digital block size 512 gt Analog block size Figure 4 7 Adding a COM meter 6 Double click the IO Tag item to edit the tag to map with the data from serial meter 7 To delete a COM port or a meter right click to the select the target item and select Delete 4 2 2 3 Ethernet I O Device Configuration ADAM 3600 is equipped two Ethernet ports user can edit delete and add devices through IR TU Studio 1 Double click or right click the TCP item under the Data Center in the left side tree view and choose edit as shown in the following figure to edit the port F Ha Advantech iRTU St
17. ag will be listed in the list 4 2 3 4 2 3 1 Protocol Service Configuration The ADAM 3600 C2G is an open basis intelligent RTU which is able to integrate many kinds of communication protocol to communicate with the center station And it is default with two standard protocol services Modbus and DNP3 Modbus Service The ADAM 3600 C2G can be used as Modbus Server for Modbus Client accessing There are two types of services supported Modbus TCP Server and Modbus RTU Server Users can check the Checkbox to enable the services fill all the required parameters for these services and click Apply Note if all the serial ports are occupied there will pop up and error message while you enable the Modbus RTU Server Go back to Data Center tree view to release COM port resource To release the COM port right click on the resource and select Delete the resource will be remove from the Data Center configuration ADAM 3600 C2G Modbus address mapping Modbus Client request data of Server by Mod bus addressing Thus in the lower table is an interface to map the tags with Modbus address To add tag into Modbus address list please double click the field of column Tag Name and select the tag from the tree view as shown on below figure And select the Tag Type from the draw down list If the tag is an analogue type Al AO please also select the related Data Type from the draw down list The Modbus Address
18. aunnnaunnnnunnnnnnnnnunnrnr Product Key Features Vs d ADAM 3600 C2G Specifications 5 2 2 1 ADAM 3600 C2G Specification of Main Unit 5 2 2 2 Expansion Module Specifications see eee ee ee ee 7 CEE MAGICAL ON TTT 8 Figure 2 1 LED Indicator Ran anne nnne nennen 8 23 1 SOV SIO LED E EE EEEE ENE EEES 9 2 3 2 Digital Input Output Indicator LED sese eee 9 2 3 3 Serial Communication LED 9 23 4 S DEE 9 IRTU Rens 10 Figure 2 2 ADAM 3600 Dimensions oocccocncccnccnccnocncccnnnancnanonanos 10 Wiring and Installation 11 A VNC a ee ee dt to 12 3 1 1 Power Supply Wiring eee eee e eee ee 12 Figure 3 1 Power Supply Wiring sese ee ee ee ee eee ee 12 SR EE Input Output Wiring 12 Figure 3 2 Analog Input Wiring se eee eee ee ee eee e 12 Figure 3 3 Digital Input Wiring s sese e eee ee ee ee eee 13 Figure 3 4 Digital Output Wiring ee ee eee 13 31 3 Senal POT WIING T 13 Figure 3 5 Serial Port Wiring eres 13 MRS VAN AION EEE KN 14 3 2 1 Wall mounted and DIN Rail Installation 14 Figure 3 6 Wall mounted Installation 14 Figure 3 7 DIN Rail Installation 14 3 2 2 Wireless Module Installation 15 Figure 3 8 Wireless Module Installation
19. built in real time operating system and a real time database providing customers with an open interface and supports diverse programming languages System Architecture webacg Es Real time monitoring water network E RTU Studio Remote management and maintenance T U 3 E A o i NZ Er Es YT p E q j dinan P is Piezometer f f pec valve Water level gauge Figure 1 1 iRTU Application Architecture ADAM 3600 Series User Manual 2 Chapter 2 Specifications 2 1 Product Key Features Wireless communication for high efficient transmission An RTU is usually applied to a wide range of monitoring such as oil field or oil pipe lines In wide area environments wired communication often has cost and mainte nance problems The ADAM 3600 C2G series two built in Mini PCle cards slots and can support two types of different wireless communication interfaces The supported wireless communication functions include GPRS 3G Wi Fi and Zigbee users have many choices in the application of wireless communication and are not restricted by field conditions High performance low power CPU RAM The ADAM 3600 C2G comes with a 32 bit Cortex A8 600MHz CPU and DDR3 mem ory chips which greatly improves the processing speed and efficiency Based on these advantages and its unique low power design customers could take their time to tackle complex logic programs Wide range of opera
20. dress 00001 u Scale Service Start Bit Bias 2 System gt 0 Length bit 16 Span High Initial Value 0 Span Low Description Clamp Clamp to low m r Clamp to high Clamp to zero Figure 4 10 Configuring a TCP Meters I O 6 iRTU Studio default provide 1 TCP port for Ethernet IO configuration if user need another TCP port please right click on the Data Center and select Add Port 27 ADAM 3600 Series User Manual 7 Inthe Type field of New Port page select TCPIP and input the related parameters for the serial port Then click button Apply a new TCP port will be HG Advantech iRTU Studio e Project Help LU 4 1 v MD s El 0 E Close Save Device Password Project Search Setting act Configuration EY COMI RTU 1 EY New Port RTU 14 x 2 Edit new port information 4 Afte editing click Apply Oil pilot plant RTU 18 1 New Port Cancel Chan 1 Data Center L Right click 3 8 YO Data Center General Information 0 99 COMI Le COM2 select Add Type TCPIP gt Scan Time ms 1000 y com3 Port XBee XBee PRO y Name Time Out ms 3000 mm TCP TCPIP 3 Select TCPIP x ZigBee miniPCle USB Description Retry Count 3 Fr his Auto Recover Time s 10 i tg User Tag 4 62 Service TRS System RTU 2 2 Data Center E Service 2 System Figure 4 11 Adding and Editing TCP Ports 4 2 2 4 Zigbee Wireless I O Device Configuration A Zigbee wireless communication module can be added to
21. e 4 28Password Settings 38 ADAM 3600 Naming Rules 39 ADAM 3600 Naming Rules 40 Figure A 1 ADAM 3600 Naming Rules 40 Interface Definition 41 Interface Definitions rara 42 B 1 1 Communication Ports rara 42 B 1 2 I O Interface Definition na 44 ADAM 3600 Series User Manual vi Chapter 1 Introduction 1 1 Product Concept amp Target Market The ADAM 3600 C2G is an Intelligent Remote Terminal Unit iRTU mainly for the oil amp gas and water industries Intelligent network nodes in loT can control the down stream field devices to complete delivery tasks transfer data to upstream devices wired or wirelessly It is a key to connecting devices to the Internet of things architec ture In the remote and wide ranging oil gas and water application site maintenance and updating equipment is extremely costly Intelligent RTU can perform remote monitor ing operation maintenance and updates via the Internet RTU can perform up date complete delivery tasks at the site and update data to the cloud RTU can also com municate with each other quickly handle I O correlation on emergencies to reduce the loss The ADAM 3600 has a high performance and low power processor adopts 20 local O points and wired and wireless communication modes users can collect process and distribute the local information It has a
22. e XBee PRO M Scan Time ms 1000 Name Time Out ms 3000 TCPIP Description Retry Count 3 Auto Recover Time s 10 EF Serial Port Setting Port miniPCle USB v Baud Rate 9600 v Parity None v Data Bit 8 v RTS False v Stop Bit 1 v DTR False v El Extension Properties ID PAN ID 64 bits SC Scan Channels bitfield SD Scan Duration exponent ZS ZigBee Stack Profile NJ Node Join Time second Figure 4 12 Adding a New ZigBee Port 5 Right click the port created on the previous step and select Add Meter to add meter 6 Inthe New Meter page type in the name and related parameters and click Apply to add meter While the meter added there is a new item I O Tag below the meter click the in front of the port and meter to unfold it a Project Help Advantech iRTU Studio fe atoa sa F 1 TOP Meter ES Use a Add Meter Serice M Delete Meter Type Unit Number Description ke System RTU 22 2 la Data Center 4 22 Service EG System Ek Extention Properties ZigBee 64 bit Address 000000000000ffff ZigBee 16 bit Address Oxfffe Use ASCII Protocol 0 Packet Delay ms Figure 4 13 Adding a ZigBee Meter Modicon 1 Wireless Dynamometer 29 Close Save Device Password Project Search Setting ict Configuration EY COMI RTU 1 EX New Port RTU 1 ES Hew Meter RTU 1 x lt 2 Edit ZigBee meter information Oil pilot plant RTU
23. el output is activated 2 3 3 Serial Communication LED 2 3 4 Ethernet LED Light on LAN 1 is unconnected with Ethernet Blinking LANT is sending data to Ethernet Light on LAN2 is unconnected with Ethernet Blinking LAN2 is sending data to Ethernet 9 ADAM 3600 Series User Manual 2 4 iRTU Dimensions O0000000000000B800000B600000000000000000000000000000000000 avse EE o mn VE H aaa Figure 2 2 ADAM 3600 Dimensions ADAM 3600 Series User Manual 10 Chapter 3 Wiring and Installation 3 1 3 1 1 3 1 2 3 1 2 1 Wiring Power Supply Wiring ADAM 3600 C2G supports mains input ranging from 10 Vpc to 30 Vnc Users can choose standard 12 Vpc or 24 VncC power supply Standard Industrial 12 or 24 Voc Power Supply Figure 3 1 Power Supply Wiring 3 1 2Input Output Wiring Analog Input Wiring ADAM 3600 C2G equips with 8 channels Al with differential wiring type wire as shown below AI Signal Se HM om om om Ha Figure 3 2 Analog Input Wiring ADAM 3600 Series User Manual 12 3 1 2 2 Digital Input Wiring The ADAM 3600 C2G is equipped with 8 channels DI follow the below diagram for wiring The pin COM is for positive voltage wiring and provides a pull high voltage to the unwired pins Normally user can leave it empty and consider wiring while the field interference is significant Mo i L k i 123 Figure 3 3 Digital Input Wiring 3 1 2 3 Digital Outpu
24. etwork For the network security there are three mechanisms available Open No password needed the RTU will auto connect to the Wi Fi network WEP A kind of network encryption Need password check the password of connected Wi Fi Access Point WPA WPA2 PSK A kind of advanced network encryption Need password check the pass word of connected Wi Fi Access Point 4 an i io mu H Advantech iRTU Studi Project Help Ea E a Ho E Close Save Device Password Project Search Setting act Configuration c COMI RTU 1 I O Setting RTU 1 7 Network Setting RTU 1 x Oil pilot plant RTU 18 1 Network Setting Apply Cancel chang Data Center Service ai Wired Network Setting 2 System 1 0 Setting LAN LANI 2 Network Setting IPv4 IPv6 RTU 2 2 Data Center DHCP VI DHCP Service IP Address 0 0 0 0 ke System Submask 0 0 0 0 Gateway 0 0 0 0 A Wi Fi j re Set Wi Fi information Network SSID Advantech Test Security WEP Y Password ser Figure 4 22 Wireless Network Settings 35 ADAM 3600 Series User Manual GPRS Settings In the GPRS setting section user has to choose the GPRS connection to join the network and make sure the Connect has been clicked amp G HQ Advantech iRTU Studio e IBG Project Help a P E a 1 Ao E E Close Save Device Password Project Search Setting Project Configuration e M Modbus Server sampledevice 7 Network Setting sampledevice x 3 4
25. f this warranty as a consequence of such events Because of Advantech s high quality control standards and rigorous testing most of our customers never need to use our repair service If an Advantech product is defec tive it will be repaired or replaced at no charge during the warranty period For out of warranty repairs you will be billed according to the cost of replacement materials service time and freight Please consult your dealer for more details If you think you have a defective product follow these steps 1 Collect all the information about the problem encountered For example CPU speed Advantech products used other hardware and software used etc Note anything abnormal and list any onscreen messages you get when the problem occurs 2 Call your dealer and describe the problem Please have your manual product and any helpful information readily available 3 If your product is diagnosed as defective obtain an RMA return merchandize authorization number from your dealer This allows us to process your return more quickly 4 Carefully pack the defective product a fully completed Repair and Replacement Order Card and a photocopy proof of purchase date such as your sales receipt in a shippable container A product returned without proof of the purchase date is not eligible for warranty service 5 Write the RMA number visibly on the outside of the package and ship it prepaid to your dealer Part No XXXXXXXXXX Edit
26. gBee Meter I O Configuration 8 To delete a Zigbee port or a meter right click to the select the target item and select Delete 4 2 2 5 User Tag Configuration We mainly introduced I O tag configuration in the former articles while there are some non actual I O tags in the project configuration which allow users to choose and configure This is called as user tag These user tags could be used for C language and KW language program ming as a control signal as well as a presentation of computation results In a word all of these user tags will fulfill user s demands for data IRTU Studio supports user tag configuration Users can configure step by step into RTU as shown in the following HG Advantech iRTU Studio Project Help E E a a A do 3 H mA Close Save Device Password Project Search Setting REAREN COMI RTU 1 Ed User Tag RTU 1 x Oil pilot plant RTU 1 1 User Tag 7 5 Data Center 1 0 Name Data Type Value Description E7 COMI K Local Tagi Analog 0 User Tag 1 EF COM2 i EF COM3 Ea TOP 43 ZigBee miniPCle USB it Ei System Tag Service 4 Edit 2 System 1 Right click and ES RTU 2 2 ES select edit sa Data Center Service AF Basic E R S D System U 3 Edit user tag basic information Name Local Tag Data Type Analog v Initial Value 0 Description User Tag 1 ADAM 3600 Series User Manual Figure 4 15 User Tag Configuration 30 2 Click Add 4 Afte editing click Apply The t
27. ion 1 Printed in Taiwan April 2015 ADAM 3600 Series User Manual il Declaration of Conformity CE The ADAM 4000 series developed by Advantech Co Ltd has passed the CE test for environmental specifications when operated within an industrial enclosure ADAM 4950 ENC Therefore in order to protect the ADAM modules from being damaged by ESD Electric Static Discharge we strongly recommend that the use of CE com pliant industrial enclosure products when using any ADAM module Technical Support and Assistance 1 Visit the Advantech web site at www advantech com support where you can find the latest information about the product 2 Contact your distributor sales representative or Advantech s customer service center for technical support if you need additional assistance Please have the following information ready before you call Product name and serial number Description of your peripheral attachments Description of your software operating system version application software etc A complete description of the problem The exact wording of any error messages lil ADAM 3600 Series User Manual ADAM 3600 Series User Manual Contents Chapter Chapter Chapter 1 2 2 1 2 2 2 3 2 4 3 3 1 3 2 3 3 IntroductioOn as rannrnnnennnennnenannunnnnsnnennne I Product Concept amp Target Market 2 Figure 1 1 RTU Application Architecture 2 Specifications arannan
28. ion to finish the calibration Note The analogue I O is default well calibrated and we do not recommend q user do the calibration by one self Once the calibration is needed we B suggest sending back to RMA for calibration service ADAM 3600 Series User Manual 34 4 2 4 2 Network Function Setting The ADAM 3600 C2G supports wired and wireless network connections to communicate with other devices User has to configure the network environment in this section Cable Network Settings The ADAM 3600 C2G has two Ethernet ports and users can configure them respectively Under the concomitances that Ethernet ports supports IPv4 and IPv6 users can set RTU as DHCP or fixed IP Ha Advantech iRTU Studio JE Project Help ra a a x 4 Ho 1 Eg Close Save Device Password Project Search Setting act Configuration EY COM1 RTU 1 UO Setting RTU 1 Z Network Setting RTU 1 x Oil pilot plant RTU 1 1 Netwo rk Setting Apply Cancel Chang Data Center Service n Wired Network Setting System EB Y O Setting LAN LAN1 y A Network Setting IPv4 IPv6 RTU 2 2 H Data Center DHCP Dynamic Host Configuration Protocol MPH Dynamic Host Configuration Service IP Address 0 0 0 0 Protocol System Submask 0 0 0 0 Gateway 0 0 0 0 2 Wi Fi Setting Network SSID Security Open i x Figure 4 21 Wired Network Settings Wireless Network Settings In the Wi Fi setting section users have to input an SSID to join the n
29. ncludes two parts I O setting and network setting 1 0 Settings The ADAM 3600 C2G is equipped with 8 Al channels 8 DI channels and 4 DO channels Besides there are four I O expansion slots which can integrate various I O modules into the main unit In the Studio for both on board I O and expansion I O user can set mode I O range integration time as well as calibration Configure the I O setting as below figures to provide an initiated setting to the on board I O and expansion I O 1 Al supports 4 IO ranges 10V 2 5V 0 20mA 4 20 mA 2 DI supports 2 modes Normal amp Counter 3 DO supports 2 modes Normal amp PWM The figure below shows the configuration page the ADAM 3600 C2G on board IO Al DI DO in the same page EG Advantech iRTU Studio Je Project Help Q Ci MH 4 amp Ss Close Save Device Password Project Search Setting ct Configuration EJ COM1 RTU 1 EBI O Setting RTU 14 x 5 Afte editing click Apply Fees I O Setting ef o Data Center a 2 service l Double click I O SB etti na a g X Network Setting 2 Click ADAM RTU 2 2 3600 C Data Center 0 5 Service 3 8 System Slot1 Slot2 Slot3 Slot4 OnBoa rd IO Calibration 3 Edit IO name range code and integration name 4 Edit DI DO mode Type Name Range Code Integration Time Type b AIO 10V 50Hz b DIO Normal All 10V 50Hz Dn Normal AI2 10V 50Hz DR Normal 10 AI AB 10V 50Hz 10 DI DI3 Normal AI4 10V 50Hz DI4
30. needed to install each card and then the antenna could be installed More details as follows he Figure 3 8 Wireless Module Installation Expansion Input Output Module Installation The ADAM 3600 C2G has four expansion slots named A B C and D with a black cover The following is the installation methods when customers need to plug expan sion modules Figure 3 10 Expansion Input Output Module Installation 15 ADAM 3600 Series User Manual 3 2 4 Writeable Label To make it more convenient for users to record RTU device information we espe cially design a writeable label on the cover User can write any information to help to keep some important project information Figure 3 11 Writeable Label 3 2 5 SD Card Installation The ADAM 3600 C2G supports two types of SD cards used as storage One is Micro SD which carries the OS The other is a Standard SD for storing data It is available for users to choose and configure The installation location of Standard SD is at the bottom of the antenna poke the black blade upward and you will find the slot insert the SD card push the black cover downward as follows Figure 3 12 Card Installation ADAM 3600 Series User Manual 16 3 2 6 SIM Card Installation When customers install a 3G GPRS module they need to insert a SIM card follow below diagram to install the SIM card The SIM card is micro SIM 3FF type Figure 3 13 SIM Card Installation 17 ADAM 3600 Series U
31. ns before quoting This guide is intended for reference purposes only All product specifications are subject to change without notice No part of this publication may be reproduced in any form or by any means electronic photocopying recording or otherwise without prior written permis sion of the publisher All brand and product names are trademarks or registered trademarks of their respective companies O Advantech Co Ltd 2015
32. pe Q type Double click to edit ma AI AO DI DO different due to tag type x Figure 4 17 Adding I O Tag Information To connect with WebAccess users should click WebAccess WherelAm Make sure that the physical IP address with WebAccess is right The parameter definition as below IP Address physical IP address with WebAccess Port default TCP port for WebAccess Period s for connecting with WebAccess Center Duration s communication time it should be shorter than Periods the default value 0 means there is no interruption during communication with WebAccess M Modbus Server sampledevice x Modbus Server Apply Cancel Change Y Modbus TCP Modbus RTU Port Number 502 Device ID Max Users 16 Port Idle Time s 300 Baud Rate M WebAccess WherelAm Data Bit IP Address 172 21 23 45 Stop Bit Port 504 Parity Period s Durations s 0 Tag Name Tag Type Address Modbus Address Data Type gt ai0 Al 0001 30001 32 bit Floating points ail AI 0003 30003 32 bit Floating points ai2 AI 0005 30005 32 bit Floating points ai AI 0007 30007 32 bit Floating points a4 AI 0009 30009 32 bit_Floating_points ais AI 0011 30011 32 bit Floating points ai6 Al 0013 30013 32 bit_Floating_points ai7 Al 0015 30015 32 bit_Floating_points dio DI 0001 10001 dil DI 0002 10002 di2 DI 0003 10003 Figure 4 18 WebAccess wherelAM ADAM 3600 Series User Manual 32 4 2 4 4 2 4 1 System Settings The system setting of R TU Studio i
33. rage Operating Temperature 40 70 C Storage Temperature 40 85 C 5 ADAM 3600 Series User Manual 2 2 1 2 Input Output Specification Voltage Current Range 10M 2 0 1 or better Full Scale N Z gt 3 5 CIS S 3 o 319 oj 3 g gt O 5 Ulu o gt SISSIG S 3 gt lt D gg 22181918 O O O O O O O 3 I I NIN 2 Digital Input Pulse Input Channel Input Type Sink Wet Contact Counter Wet Contact Input Logic0 O 5 Vic Logic 1 11 30 V pc Rated Voltage 12 24 VDC Rated Input Current gt 5mAQ 12Vpc gt 1 OmA Q24Vnc Digital Output Pulse Output Over Voltage Protection Pulse Output Frequency 2 2 1 3 Environmental Specifications E Operating Temperature 40 70 C E Storage Temperature 40 85 C Operating Humidity 20 95 non condensing M Storage Humidity O 95 non condensing ADAM 3600 Series User Manual 6 2 2 2 Expansion Module Specifications ADAM 3600 C2G support four slots expansion can support different type I O mod ules in one integrated unit 2 2 2 1 ADAM 3617 4 ch Al Input Impedance 10MQ Accuracy 140 1 or better Full Scale 2 2 2 2 ADAM 3618 3 ch Thermocouple Accuracy 140 1 or better Full Scale 2 2 2 3 ADAM 3622 2 ch AO 0 1 or better Full Scale 7 ADAM 3600 Series User Manual 2 2 2 4 ADAM 3651 8 ch DI PI Input Type Sink Wet Contact Counter Wet Contact Input Logic0 O 5 Vic
34. ser Manual 3 3 Jumper Switch Settings 3 3 1 DIP Switch Settings ADAM 3600 C2G IO has two DIP switches as follows T EA REE ADAM 3600 IO Figure 3 14 DIP Switch Setting Description 1 SW6 Node ID 6 bit supports 0 63 devices ON 1 OFF 0 1 is for high bit 6 is for last bit ex 000001 1 100000 32 2 SW5 8 ch Al Current or voltage ON Current range select OFF Voltage ADAM 3600 Series User Manual 18 3 3 2 Jumper Settings The ADAM 3600 CPU has two Jumpers as follows ADAM 3600 CPU COM1 DB9 Port select RS 232 or RS 485 CN15 Watchdog Enable Jumper ON Enable OFF Disable 19 ADAM 3600 Series User Manual ADAM 3600 Series User Manual 20 Chapter 4 Advantech IRTU Studio 4 1 4 2 4 2 1 4 2 1 1 IRTU Studio Introduction If there s one or more RTU devices in the field site it s more convenient for users if there is a tool to complete the integrated configuration and remote management For this Advantech developed a utility software to facilitate these tasks Advantech iRTU Studio can be operated in Windows XP Windows 7 system and has the fol lowing functions m Provide interface for off line project configuration and remote deploy the config uration base on the adjustable NodelD M Easy to configure the project tags with actual engineering meaning and easy to map these tags to the Modbus and DNP3 services m Users could set each input and output range and support
35. setting is incorrect or the device is actu ally not in the network the status will show off line Device Search Device Name Node ID IP Address Status sampledevice 12 172 21 67 174 Online Search Close Figure 4 25 Identification for Connected RTU Devices 4 3 2 Project Download While all the RTU devices are no line click Project Download to download the project into the RTU devices If users click and active the project node on the left hand side tree view and click the Project Download user can download the whole project to all the devices on line by one click If users only click and activate one target device on the tree view the Project Download will only download the project to the selected device Project Download x Name Status Progress sampledevice 12 Completed 100 Download l Close Figure 4 26 Project Download 37 ADAM 3600 Series User Manual 4 3 3 Password Settings For security the ADAM 3600 C2G has a default password 00000000 and iRTU Studio also sets it as the default password for RTU devices RTU 1 1 General Information Name RTU 14 Device Type Password Ker Indentity Node ID hd Node ID 1 IP Address Description Oil pilot test 1Zdevice Figure 4 27 Password Information To change the password follow the steps below 1 iRTU Studio connects with the RTU device and it has been identified 2 Click password setting select the device input the
36. t Wiring ADAM 3600 C2G is equipped with 4 channels DO follow the below diagram for wir ing DO Signal Coen Figure 3 4 Digital Output Wiring 3 1 3 Serial Port Wiring ADAM 3600 C2G is equipped with 3 serial ports the COM2 3 are for RS 485 and locate on the orange terminal please follow the below diagram for wiring m Rais a 3 93 am IO Mg Figure 3 5 Serial Port Wiring 13 ADAM 3600 Series User Manual 3 2 Installation 3 2 1 Wall mounted and DIN Rail Installation The ADAM 3600 C2G supports two types of installation Wall mounted and DIN Rail Installation For wall mounted installation users can fix the device on the wall with 4 screws as shown below Figure 3 6 Wall mounted Installation For DIN Rail installation follow the below diagram to put the device on the DIN Rail and lock the 3 lock to fix the device on the DIN Rail 2838 000000 M Ss cr as aco 2 ca a 200920 a a o Ea o q oO a a a ao a 26382 s y 88080 HEBER po UE DE PR EE 555555 552508 fi he Figure 3 7 DIN Rail Installation ADAM 3600 Series User Manual 14 3 2 2 3 2 3 Wireless Module Installation There are two wireless expansion interfaces under the gray cover which supports two Mini PCle ports and can insert wireless LAN card Two overlapping network cards can be installed The below supports half sized card while the upper supports full size card Two screws are
37. the ADAM 3600 from COM port or USB port on PCle mini card socket To get data from the Zigbee Wireless Meter use the fol lowing steps 1 Right click the Data Center on the left side tree view and select Add Port 2 Inthe Type field of New Port page select XBee XBee PRO which is the supported Zigbee driver for ADAM 3600 3 Inthe section of Serial Port Setting please select the port where the Zigbee communication module connects to and adjust related parameter to communi cate with the module Please note if the resource is shown on the tree view it is occupied by other meter the resource will not be shown on the drop down menu of the Port field ADAM 3600 Series User Manual 28 4 Click button Apply the port will be created on the left hand side tree view under the Data Center item HG roject Help a E 2 Aloo Close Save Device Project Search ifiguration le impledevice 1 1 right click Data Center Data Center t 1 0 EF COM1 COM2 COM3 fin TCP SK ZigBee miniPCle USB H System Tag Ea User Tag 2 Service System 1 O Setting Network Setting Advantech iRTU Studio Password Setting Network Setting sampledevice New Port Sf General Information 3 choose XBee XBee PRO type New Meter sampledevice EY New Port sampledevice x lt t 2 complete the information 4 click apply when the edit gt Apply Cance finished Type XBe
38. ting temperature with durability in harsh environment and reducing maintenance costs It can be used for outdoor control cabinets and therefore must be able to withstand the heat of summer and the cold of winter The ADAM 3600 supports an operating temperature range of 40 C 70 C The selected components are industrial grade and have been tested with the strictest environmental control to ensure that the products have a long life and stable working in harsh environments Convenient remote project configuration software iRTU Studio Provides project configuration software with remote operation Users can configure all the devices in an offline and group mode and can automatically conduct remote downloading based on its own code Users can use this software for remote monitor ing updating the programmable logic and firmware to save the cost of manpower and materials Supports open communication protocols In addition to the standard Modbus communication protocol it also supports the object DNP3 protocol DNP3 is an international standard for RTU applications and can also realize data identification breakpoint transmission initiative report and other functions under this protocol user can quickly integrate most of the SCADA system Multiple programming interfaces Adopts an open real time Linux system architecture and run the real time database Transmission gives priority to the customizable tag Data with a simple configuration
39. udio i x Els Project Help gt am re a 2 Al EA Close Save Device Password Project Search Setting 3 After editing Project Configuration EZ COMI RTU 1 ii TCP RTU 1 x lt a 2 Edit TCP information click Apply 3 4 Oil pilot plant i amp sa Data Center 7 8 1 0 SP General Information 5 9 COM1 EB COM2 1 Right click TOP Type Scan Time ms 1000 w COM3 select edit Name TCP Time Out ms 3000 SK Zid dl SE Description Retry Count 3 E cu cos Add Meter R s Auto Recover Time s 10 ta Us 2 Delete 9 6 Service TRS System RTU 2 2 T w Data Center Service 2 System N Figure 4 8 Editing TCP Information 2 Right click TCP item choose Delete the port will be deleted after your confir mation 3 Right click TCP item choose Add Meter to add a meter ADAM 3600 Series User Manual 26 4 Inthe New Meter page type in the name and related parameters and click Apply to add meter While the meter added there is a new item I O Tag below the meter click the in front of the port and meter to unfold it A 2 Advantech iRTU Studio E Project Help Ai amp p a E Close Save Device Password Project Search Setting act Configuration COMI RTU 1 EJ New Meter RTU 1 x x 2 Add meter information 3 After editing ie Apply oil pilot plant er New Meter ww mates sa Data Center a 1 0 4 E T General Information Bw com 1 Right
40. vice Password Project Search Setting r x Z Project Configuration RTU 1 Eo IO Tag RTU 1 BoardIO x 2 Click Add i Oil pilot plant SB RTU 1 1 I O Tag ma Delete Ela Data Centerl Double EEB y0 click IO Tag Name Data Type Address Conver Scale T Description i E E BoardIO Tempi Analog ALO N A No Scale Temperature sensor 1 EE sj 10 Tag gt Temp2 Analog ALI N A No Scale Temperature sensor 2 Y S COM1 4 After editing click Apply E COM2 gt Cancel Change ns IO tage will be listed i ET COM3 n TCP T Basic Q 3 Edit tag basic information El Advanced 43 ZigBee miniPCle USB p I ER System Tag Name Temp2 ScalingType No Scale E E F User Tag Data Type Analog Formula Service L I Address 7 System AL1 EB RTU 2 2 Initial Value 0 Scale Description Temperature sensor 2 Bias Span High Span Low Clamp amp to amp to hig N Clamp to Figure 4 5 Configuring Onboard I O ADAM 3600 Series User Manual 24 For the analogue I O tags RTU Studio provides the Advanced function for user to do the scaling In the dialog window many kinds of formulas are provided for user to scale the mea sured signal to the corresponding real physical signal 4 2 2 2 Serial I O Device Configuration The ADAM 3600 has three serial ports including 1x RS232 RS485 2 x RS485 iRTU Studio can edit delete and add device on these three ports 1 Right click the Data Center on the left side tree view
41. w project users can right click on the project name to check the project information and add new devices To add devices user need to input the name device type Node ID and description The field of password contains the default set ting user can change it in Deploy taskbar Password Setting See more details in Article 1 3 3 After finish the device adding user s can modify the device information by double click the device name on the left hand side tree view or right click on the device name and choose 111 1 edit A P ES New Device x Eles m IE Project Help Devi ce Apply Cancel Change ca Tr 3 do r General Information Close Save Device Name RTU 1 Project Search gt ET Fane ype ADAM 3600 C2G Password Indentity Node ID Project Configuration aes ml Oil pilot ph IP Address A Properties Description Oil pilot test 1 device cp Add Device Figure 4 2 Adding Devices and Editing 4 2 1 3 Copying Devices To reduce the complexity of configure a lot of ADAM 3600 on the field IRTU Studio supports the ability to copy device information within a project Users can right click on the device name and choose copy The copied device will have the same configuration as the original device but user still need to be modify the name NodelD or IP as well as the description according to the project planning Project Configuration ue P oil pilot plant EM E DE 5 Dal gay H Sel