1. 95 9 f 90 0 F 30 0 C 31 5 C 94 5 F 99 14 F 34 7 C 37 3 C 96 44 F 100 4 F 35 8 C 38 C TEMPORAL FeverWatchers 96 44 F 100 F 35 8 C 37 8 C The temperature of the human body varies throughout the day It can also be influenced by numerous external factors age sex type and thickness of skin etc FeverWatchers RC802i User Manual English V 02 201009 6 ADVANTAGES OF TEMPORAL ARTERY TA TEMPERATURE Infrared arterial temperature can be measured using a device placed on the forehead in the temporal artery region It has been demonstrated that this relatively new method of measuring temperature is more precise than tympanic thermometry and more tolerable than rectal thermometry The FeverWatchers RC802i thermometer has been designed to produce an instant forehead temperature reading without any contact with the temporal artery As this artery is quite close to the surface of the skin and therefore accessible in addition to the blood flow being permanent and regular allowing precise measurement of thetemperature This artery is linked to the heart by the carotid artery which is directly linked to the aorta It forms part of the main trunk of the arterial system The efficiency speed and comfort of taking a temperature from this area make it ideal when compared with other temperature measurements methods NORMAL TEMPERATURES ACCORDI NG TO AGE Age u F PRACTI CAL CONSI DERATI ONS WHEN TAKI NG
2. C Confirm by pressing PROG SETTING button Note The alarm threshold default value is 100 4 F 38 C FeverWatchers RC802i User Manual English V 02 201009 12 3 CHOICE OF DISPLAY MODE BODY OR SURFACE TEMP F3 MENU The FeverWatchers RC802i is specially designed to take the body temperature of a human being For this use the BODY mode Measurement range for Body mode 90 F 109 F 32 C 42 9 C You can also use the FeverWatchers RC802i to measure the temperature of an area or an object a food product a liquid or the room temperature For this use the SURFACE TEMP mode Measurement range for Surface TEMP mode 32 F 140 F 32 C 60 C Press PROG SETTING button for 3 seconds the screen displays Fl Press PROG SETTING button twice to get to F3 Select 0 by pressing button to get the BODY mode Select 1 by pressing button to get the SURFACE TEMP mode Confirm by pressing PROG SETTING button Note The FeverWatchers RC802i is automatically set to BODY at the factory Important The area temperature differs from the internal body temperature To obtain the internal temperature always use the BODY mode Please make sure to select the BODY mode for an internal temperature reading and the SURFACE TEMP mode for an external area reading bottle bath room FeverWatchers RC802i User Manual English V 02 201009 13 4 TOTAL DIFFERENCE F4 MENU To adjust the total variation of your
3. temperature to be taken at a distance of approximately 2 inches 5cm from the forehead Precise instantaneous and without contact the FeverWatchers RC802i is to date the most suitable thermometer for no risk temperature measurement It has been demonstrated that this method of TA temperature measurement is more precise than tympanic thermometry and less invasive than rectal thermometry 1 However as with other types of thermometers the FeverWatchers RC802i must be used properly in order to obtain reliable and stable results You are therefore advised to read the instruction manual and the safety precautions carefully before use 1 Greenes D Fleisher G Accuracy of a Noninvasive Temporal Artery Thermometer for Use in Infants Arch Pediatr Adolesc Med 2001 155 376 Ill PRECAUTIONS BEFORE USE The FeverWatchers RC802i is pre set at the factory It is not necessary to calibrate the device when starting it up In order to obtain reliable and stable results you are advised to allow the FeverWatchers RC802i to acclimate to any significant changes in the ambient temperature due to a change in environment for 15 to 20 minutes before using it It is important to allow a one minute interval between two measurements FeverWatchers RC802i User Manual English V 02 201009 4 IV OPERATING PRI NCI PLE All objects solid liquid or gas emit thermal energy by radiation The intensity of this energy depends on the temperature of
4. A TEMPERATURE In order to ensure that precise and accurate temperature measurements are obtained it is essential that each user has received adequate information on and training in the temperature measurement technique when using such a device It is essential to remember that although procedures such as taking a temperature may be simple they must not be trivialized Temperature should be taken in a neutral context The patient must not have undertaken vigorous physical activity prior to taking FeverWatchers RC802i User Manual English V 02 200109 7 his her temperature and the room temperature must be moderate Be aware of physiological variations in temperature which must be taken into consideration when evaluating the results temperature increases by 0 9 F 0 5 C between 6am and 3pm Women have a temperature that is higher on average by around 0 3 F 0 2 C Their temperature also varies in accordance with their menstrual cycle The temperature rises by 0 9 F 0 5 C in the second half of the cycle and at the early stages of pregnancy When sitting temperature is lower by about 0 5 F to 0 7 F 0 3 C to 0 4 C than when standing HOW TO TAKE A TEMPERATURE Aim at the FOREHEAD over the right temporal region from a distance of about 2 in 5cm press the thermometer s measurement button and the temperature is instantly displayed The reliability of the measurement cannot be guaranteed if the temperature I
5. ECI SION From 34 C to 35 9 CS 03 C From 93 2 F to 96 6 F 0 3 F According to ASTM From 36 C to 39 C 0 2 C Standard E1965 1998 2003 From 96 8 F to 102 2 F 0 2 F From 39 C to 42 5 C 0 3 C From 102 2 F to 108 5 F 0 3 F The FeverWatchers RC802i can take temperature readings below 32 C or above 42 9 C 90 F to 109 F but precision is not guaranteed outside of this range LONGEVITY OF ACCURACY The FeverWatchers is guaranteed for 40 000 readings X ADVICE The protective glass over the lens is the most important and fragile part of the thermometer please take great care of it Clean the glass with cotton fabric wet with water or 70 proof isopropyl alcohol Do not use other batteries than alkaline batteries do not recharge non rechargeable batteries do not throw in fire Remove the batteries when thermometer is not used for an extended period of time Do not expose the thermometer to sunlight or water An impact will damage the product XI ACCESSORIES SUPPLI ED User Manual in English Quick Start Guide Guarantee card Batteries supplied AA FeverWatchers RC802i User Manual English V 02 201009 16 XI I TROUBLESHOOTING If you have one of the following problems while using your FeverWatchers please refer to this breakdown service guide to help resolve the problem If the problem persists please contact our customer service at sales clinicalguard com THE SCREEN DISP
6. FeverWatchers www FeverWatchers com p gt L T O 2 TT Model RC802i Clinically Tested FDA Cleared Contents 201 ELY PIECAULONG ernennen 3 la Ligo Kal nee heine 4 Iil Precautions Before ses 4 IV Operating PANGPIE sine 5 The Different Methods of Temperature Measurement Normal Temperatures According to Measurement Method 6 Advantages of Temporal Artery TA Temperatue 7 Normal Temperature According to Age cccesescseeseeeeeeeeeeeeeeees 7 Practical Considerations When Taking A Temperature 7 How to Take A Temperature Uu nangaling 8 ea Nal ea ee 8 V Description of The Feverwatchs RC802i X A S 9 RA eo AA AA 11 Mil USE ee ee ee 11 Vili Seting amp FUNCTION OT een 12 1 Choosing The Temperature Unit FI Mel oo aaa nn nun nennen nenn 12 2 Alan Setup 2 Meg NG aapakan Kahn BN Aka 12 3 Choice of Measurement Mode Body or Surface Temp F3 Menu ssssusususaas 13 A Total Difference gt EA Ma nn nennen 14 5 Buz r QU N FRE een 14 No Tile Ub Ci ALL APA AA AA AP 14 7 DALAWICMOlY oem 14 8 Chgmalng The Batterie seecnscsrninaderina arenes NANANA 15 As Technical Characterisies amp PRECISION asaan ina 15 AG AAP AMA 16 XI Accessories SUBRIIEd u n un GA NG AA 16 Alle TTOUDIES NOO UNO ama AA NAA 17 FeverWatchers RC802i User Manual English V 02 201009 2 SAFETY PRECAUTIONS Follow
7. FeverWatchers RC802i Press PROG SETTING button for 3 seconds the screen displays F1 Press PROG SETTING button three times to get to F4 Select to increase the difference by 0 1 F 0 1 C to reduce it by 0 1 F 0 1 C Confirm by pressing PROG SETTING button If in doubt you are advised to leave the total variance at 0 F 0 C This is the original factory setting Note The variance setting exists as a way to offset the difference between the axillary and temporal artery measurements Normally this setting does not need to be adjusted unless fine tuning the device is need due to skin condition differences Each time there is a significant change in the ambient temperature due to a change in environment to allow the FeverWatchers RC802i to acclimatise to this ambient temperature for at least 15 minutes before using it 5 BUZZER ON OFF F5 MENU Press PROG SETTING button for 3 seconds the screen displays Fl Press four times PROG SETTING button to get to F5 Select to open the buzzer a sound icon is displayed on the LCD screen press to stop it the icon disappear Confirm by pressing PROG SETTING button 6 EXI TI NG THE SETTING MODE Press PROG SETTING button until the screen turns off 7 DATA MEMORY To display the last temperature measurement press simultaneously the and button FeverWatchers RC802i User Manual English V 02 201009 13 You will obtain the
8. LAYS TEMPERATURE GREATER THAN 95 The temperature is in Fahrenheit change the measurement to Celsius by pressing the Program Setting button to get the F1 function key THE SCREEN DISPLAYS THE BODY TEMPERATURE LOWER THAN 32 C 89 6 F To take a body temperature the function key F3 must be on Body mode If you re on Surface Temp mode the 32 C 89 6 F temperature displayed is showing the external temperature that your body releases THE SCREEN DISPLAYS THE MESSAGE HI When using the FeverWatchers RC802i the message HI can show on the screen Hi The analysis is above the measurement 1 range selected either greater than 42 9 C 109 F in Body Mode or greater than 60 C 140 F in Surface Temp i Mode FeverWatchers RC802i User Manual English V 02 201009 17 THE SCREEN DISPLAYS THE MESSAGE LO When using the FeverWatchers RC802i the message Lo can show on the screen The temperature analyzed is under the measuring range selected either less than 32 C 90 F in Body Mode or less l than 0 C 32 F in Surface Temp Mode This message displays in various cases please find below a list of the main cases Reasons for LO message display Temperature reading hampered Make sure that there is no by hair perspiration obstruction prior to taking a temperature Advice Temperature hampered by air Make sure there is no air flow flow as this could interfere with the infrared system Temperature readi
9. S measured over another part of the body e g arm torso CONSTRAI NTS Please observe the following before any temperature measurement to ensure a stable and reliable result Push back hair from the forehead Wipe away any perspiration from the forehead Avoid any airflow e g from nasal passages air conditioning Allow a 1 minute interval between two measurements Each time there is a significant change in the ambient temperature due to a change in environment to allow the FeverWatchers RC802i to acclimate to this ambient temperature for at least 15 minutes before using it FeverWatchers RC802i User Manual English V 02 201009 V DESCRI PTI ON OF THE FeverWatchers RC802i Setting keys Prog Setting Infrared Lens Backlit LCD panel Mesuring key Trigger Battery compartment FeverWatchers RC802i User Manual English V 02 201009 RCBD2i PROG SETTING MENU BUTTON SETTING KEYS TRADEMARK FeverWatchers RC802i User Manual English V 02 201009 10 VI FUNCTI ONS 1 Specially designed to take the body temperature of a person regardless of the room temperature 2 Quick and reliable results as the device uses the HEIMMANN infrared detection system 3 Audible alarm if temperature exceeds set value 4 Memorization of the 32 last measurements 5 LCD back lighted digital screen 6 Data displayed in Celsius or Fahrenheit 7 Automatic power off energy saver 8 Small co
10. ation techniques rectal thermometry can spread germs often found in feces FeverWatchers RC802i User Manual English V 02 201009 Oral thermometry Oral temperature is easily influenced by recent ingestion of food or drinks and by breathing through the mouth To measure oral temperature the mouth must remain closed and the tongue lowered for three to four minutes which is a difficult task for young children to accomplish Use of older technologies such as Mercury based thermometers pose an additional risk of accidental breakage Axillary armpit temperature Although it may be easy to measure axillary temperature it has been proven that it does not provide an accurate measurement of the child s internal temperature To take this type of temperature the thermometer must be wedged tightly over the axillary artery Despite the low sensitivity and relative inaccuracy of axillary temperature in detecting fever this method is recommended by The American Academy of Pediatrics as a screening test for fever in newborns Tympanic thermometry In order to obtain a precise temperature reading good command of the measurement technique is required The thermometer probe must be placed as close as possible to the warmest part of the external ear canal An incorrectly placed probe could lead to a false temperature reading NORMAL TEMPERATURES ACCORDI NG TO MEASUREMENT METHOD MEASUREMENT METHOD NORMAL TEMP 97 88 F 100 4 F 36 6 C 38 C
11. last temperature measurement To switch to the previous measurement press the button The number indicated in interval of two measures corresponds to the number of measurements Press on the button to go see the next measurement To exit data memory press the measure key The FeverWatchers switches off automatically after 5 seconds 8 CHANGI NG THE BATTERIES Display when the LCD screen displays Battery the battery is low Operation Open the lid and change the batteries taking great care of the correct positioning A mistake with installing the battery could cause damage to the apparatus and compromise the warranty of your FeverWatchers RC802i Never use rechargeable batteries Use only alkaline batteries for single usage IX TECHNICAL CHARACTERISTICS 1 Normal conditions of use Operating temperature 50 140 F 10 C 40 C Humidity rate lt 85 2 Power DC3 V 2 batteries AA 3 Size 7 7 x5 9 x 1 9 in 196 x 150 x 50mm Lx W x H 4 Weight 7 70z 220g 5 Display Resolution 0 1 F 0 1 C 6 Measuring range In body mode 90 F 109 F 32 C 42 9 C In Surface Temp mode 32 F 140 F 0 C 60 C 7 Precision From 96 8 F 102 2 F 36 C 39 C 0 2 F C 8 Consumption lt 50mW 9 Accuracy 0 54 F 0 3 C 10 Measuring distance 2 in 3 14 in 5 cm 8 cm 11 Automatic stop 5 sec FeverWatchers RC802i User Manual English V 02 201009 15 FEVERWATCH PR
12. ngs too close Allow a pause of 15 seconds together the FeverWatchers did minimum between two not have the chance to reboot readings 1 minute pause is itself advised The measuring distance istoo Please respect the measuring far distance between 2 in and 3 14 in or 5 and 8 cm FeverWatchers RC802i User Manual English V 02 201009 18
13. nvenient easy to use ADDI TI ONAL USES FeverWatchers RC802i can also be used to measure the temperature of a baby bottle or bath or room temperature by using the Surface Temp function This function is in accordance with the Directive 89 336 EEC Electromagnetic Compatibility VII USE 1 Install battery 2 For the first use or when inserting new batteries wait between 10 minutes for the warm up of the apparatus and when inserting the new batteries 3 Aim towards the forehead see the diagram below for the FeverWatchs positioning from a distance of 2 in 5 cm Squeeze the trigger the temperature Is displayed in 1 second The temperature can also be taken behind the ear lobe 4 Before taking the temperature make sure to remove hair and perspiration from the forehead You can also take the temperature from behind the ear lobe FeverWatchers RC802i User Manual English V 02 201009 11 VI II CONFIGURATION AND FUNCTION OF MENU MENU BUTTON SETTING KEYS 1 CHOOSI NG THE TEMPERATURE UNIT F1 FUNCTION Press PROG SETTING button for 3 seconds the screen displays F1 Select for degrees Celsius for degrees Fahrenheit Confirm by pressing PROG SETTING button 2 ALARM SETUP F2 MENU Press PROG SETTING button for 3 seconds the screen displays F1 Press twice PROG SETTING button to get to F2 Select to increase the threshold by 0 1 F 0 1 C to reduce it by 0 1 F 0 1
14. the object The FeverWatchers RC802i infrared thermometer is therefore able to measure the temperature of a person by the thermal energy the person emits This measurement can be taken due to an external temperature probe on the device which permanently analyses and registers the directional ambient temperature Therefore as soon as the operator holds the thermometer near the body and activates the radiation sensor the measurement is taken instantly by detection of the infrared heat generated by the arterial blood flow Body heat can therefore be measured without any interference from the heat of the surrounding environment THE DI FFERENT METHODS OF TEMPERATURE MEASUREMENT Core temperature Core temperature is the most precise measurement and involves measuring the temperature in the pulmonary artery by means of a catheter equipped with a thermal probe which can read the temperature in situ The same method is employed for probes measuring the esophageal temperature However such invasive temperature measurement methods require specific equipment and expertise Rectal thermometry Rectal temperature adjusts slowly in comparison to the changes of the body s internal temperature It has been demonstrated that rectal temperature remains raised long after the internal temperature of the patient has started to drop and vice versa Furthermore rectal perforations have been known to occur as a result of this method and without appropriate steriliz
15. the maintenance advice stipulated in this instruction manual This device may be used for personal home use This device must only be used for the purposes described in this instruction manual This device must only be used in an ambient temperature range of between 50 F and 104 F 10 C and 40 C This device must always be kept in a clean dry area Do not expose this thermometer to electric shocks Do not expose this thermometer to extreme temperature conditions of gt 122 F gt 50 C or lt 4 F lt 20 C Do not use this device in relative humidity higher than 85 The protective glass over the lens is the most fragile part of the Thermometer therefore Do not touch the glass of the infrared lens with your fingers Clean the glass with a cotton swab lightly moistened with 70 proof isopropyl alcohol Do not expose the thermometer to sunlight or to water Do not use this device outside Never drop the device Should a problem occur with your device please contact your retailer Do not attempt to repair this device yourself IMPORTANT SAFEGUARDS THE MANUFACTURER RESERVES THE RIGHT TO ALTER THE SPECIFICATIONS OF THE PRODUCT WITHOUT PRIOR NOTIFICATION FeverWatchers RC802i User Manual English V 02 201009 3 Il INTRODUCTION The OctiveTech FeverWatchers RC802i Non contact thermometer was developed using the latest infrared technology This technology allows the temporal artery TA

Download Pdf Manuals

image

Related Search

ClinicalGuard.com clinicalguard.com clinical guardian login clinical guardian clinical guard pregnancy test clinical guarding clinical guardian brisdoc clinical guardian audit clinical guard pulse oximeter clinical guard oximeter clinical guard pregnancy test strips

Related Contents

Precaución Para reducir el riesgo de recibir una  VP-5ZA User Manual - Newport Corporation  exemplar de assinante da imprensa nacional  Philips exhaust filter FC8033  PDF Brochure  2004 Infiniti I35 Navigation Guide  Underwater Kinetics UK4AA Xenon Twist Bezel  DGT 300 - Redex  Xerox Phaser 6022 User's Manual  