Home
2711-2.3, Installing a User EEPROM in a Series D or E PanelView
Contents
1. s pins into the socket ATTENTION The notch on the chip MUST be on the same end as the notch on the socket When all the pins are properly positioned in their holes and the notch is on the correct side gently press the chip into the socket It will go in easily if the pins are properly positioned ATTENTION If you break or severely bend a pin the chip will be unusable 7 Close the PanelView terminal and fasten the screws then reconnect the Remote I O cable RS 232 cable and power cable Installation Data Installing a User EEPROM 8 Verify that the Panel View terminal is working properly a Connect power to the terminal b Set the terminal to Configure mode and check the User EPROM EEPROM Power up Test setting Set it to Yes c Disconnect and reconnect power to the terminal d Ifthe following message appears the EEPROM has not been installed properly is corrupted or has not been programmed Figure 3 EPROM EEPROM Minor Fault Message MINOR FAULT USER EPROM EEPROM is not installed or is corrupted 20200 If this message appears consider the following points and repeat the installation procedure if necessary make sure that the chip is seated properly in its socket and that no pins are bent make sure that the notch on the chip is on the same end as the notch on its socket it ALLEN BRADLEY Alen Bradley has been helping its customers improve productivity and quality for
2. 90 years A ROCKWELL INTERNATIONAL COMPANY A B designs manufactures and supports a broad range of control and automation products worldwide They include logic processors power and motion control devices man machine interfaces and sensors Allen Bradley is a subsidiary of Rockwell International one of the world s leading technology companies With major offices W Or d Wid c m Algeria e Argentina e Australia e Austria e Bahrain e Belgium e Brazil e Bulgaria e Canada e Chile e China PRC e Colombia e Cos a Rica e Croatia e Cyprus e Czech Republic e Denmark e Ecuador e Egypt e El Salvador e Finland e France e Germany e Greece e Guatemala e Honduras e Hong Kong e Hungary e Iceland e India e Indonesia e Israel e Italy e Jamaica e Japan eJ ordan e Korea e Kuwait e Lebanon e Malaysia e Mexico e New Zealand e Norway e Oman e Pakistan e Peru e Philippines e Poland e Portugal e P uerto Rico e Qatar e Romania e Russia CIS e Saudi Arabia e Singapore e Slovakia e Slovenia e South Africa Republic e Spain e Switzerland e Taiwan e Thailand e The Netherlands e Turkey e United Arab Emirates e United Kingdom e United States e Uruguay e Venezuela e Yugoslavia World Headquarters Allen Bradley 1201 South Second Street Milwaukee WI 53204 USA Tel 1 414 382 2000 Fax 1 414 382 4444 Publication 2711 2 3 June 1993 40061 192 01 B Supersedes Publication 2711 2 3 Dated December 1992 1993 Allen Bradley Company Printed in USA
3. B Description Installation Data Installing a User EEPROM in a Series D or E PanelView Terminal Cat No 2711 NM3 The PanelView terminal is designed so that you can install an optional user EEPROM An EEPROM can be used as backup for the application file or as 64K of additional application memory depending on its configuration in the PanelBuilder Development Software With an EEPROM used for application backup not as extra application memory the application file is automatically copied to the EEPROM when it is downloaded into the terminal For details on configuring the EEPROM for extra application memory see the PanelBuilder Development Software User Manual Chapter 3 Using PanelBuilder for more information on programming EEPROMs see the PanelBuilder Development Software User Manual Chapter 6 File Operations ATTENTION Make sure the power cable is disconnected before you open a PanelView terminal To install a user EEPROM 1 Disconnect the power cable Remote I O cable and RS 232 cable 2 Take the necessary precautions against electrostatic discharge Ideally you should use an anti static mat or wear a grounding wrist strap whenever you work with any electronic components sensitive to electrostatic discharges If you re not using an anti static mat or wrist strap follow these precautions before you touch any components inside a Panel View terminal assume your body is always carrying an electr
4. ostatic charge frequently touch any grounded metal surface to discharge yourself Installation Data Installing a User EEPROM wear cotton clothes not wool or synthetic fabrics don t move too much or scuff your feet when walking on carpets be extra careful in low humidity environments terminal are extremely sensitive to static electricity and may be A ATTENTION The electronic components in the PanelView permanently damaged by electrostatic discharges 3 Open up the PanelView terminal logic drawer Remove the two screws located near the bottom back of the unit to drop the tray containing the board Figure 1 Opening the Series D or E PanelView Terminal ii j Remove these two screws to access the logic board Color Back Panel Monochrome Back Panel 21171 4 Socket U2 is labeled User Memory as shown in Figure 2 5 Set the jumpers JP1 and JP2 to the right most pins labeled EPROM EEPROM as shown in Figure 2 Node Adapter Firmware System Firmware Installation Data Installing a User EEPROM Figure 2 PanelView Series D or E Logic Board with Jumpers JP1 and JP2 in the EPROM EEPROM Position O O O O O oQ User PROM 20319 6 Gently ease the chip
Download Pdf Manuals
Related Search
Related Contents
User Manual Husqvarna 1153191-26 Blower User Manual i-mobile240 front cover Copyright © All rights reserved.
Failed to retrieve file