Home

Reed Instruments SD-6020 User Manual (English)

image

Contents

1. 10 15 16 R 17 Zas Raa mreedinstruments csom 5 Distributed by MicroDAQ com www microdaq com reed 603 746 5524 Operating Instructions When measuring Compression the meter will show a symbol While measuring be sure to have the Sensor aligned with the object being mea sured Do not measure on an angle as the Sensor may be damaged and the readings will not be accurate 1 Turn on the meter by pressing the Power Button To turn the meter off hold the Power Button for 2 seconds 2 Select the measuring unit For instructions on this please see the Advanced Settings section 3 Connect an Adapter and the measuring object to the Sensor The measuring object should be in a straight line Do not apply any force while in Standby Mode 4 Zero Adjust the meter by pushing Zero Button before every mea surement 5 Start measuring by giving force push or pull to the Sensor The screen will display the Average reading value To change the dis play direction push the Reverse Button 6 There are two kind sampling time of display Fast and Slow The Display will indicate FAST if measuring in Fast Sampling Time and SLOW if measuring under Slow Sampling Time Push the Fast Slow Button to switch between Fast and Slow Sampling Note Over range of tension will display as and over range of compression will display as ____ Peak Hold Measurement The meter ca
2. See Advanced Settings section of this manual for instructions on how to change the Decimal Character Auto Datalogger Set sampling time 1 second 1 Start Datalogging press the REC Button and the REC symbol will appear on the LCD screen then press the Logger Button the REC symbol will flash while the measuring data and time informa tion is being saved in memory To set the sampling time and to toggle the beeper sound on or off refer to the Advanced Settings section of this manual 2 Pause the Datalogging while Datalogging if press the Logger But ton once While paused the REC symbol will stop flashing Press the Logger Button again to resume Datalogging and the REC symbol will begin to flash again continued Distributed by MicroDAQ com www microdaq com reed 603 746 5524 3 Stop Datalogging while the Datalogger function is paused press the REC Button for 2 seconds The REC symbol will disappear indicating the Datalogging function has stopped Manual Datalogger Set sampling time 0 seconds 1 Set sampling time is to 0 second Press the REC Button and the REC symbol will appear on the LCD screen Press the Logger Button and the REC symbol will flash once and one Beep will sound at the same time the measuring data along the time infor mation will be saved in memory The lower Display will show the Position record number which is saved as well 2 To Change the Po
3. 746 5524 3 Open Microsoft EXCEL Download the EXCEL files from the SD Card to the computer by opening up the SD folder and selecting the desired EXCEL files and drag and drop them onto your Com puter Open the files with EXCEL File Open 4 The EXCEL file will have the following column headers in this order Place Position Number Date Year Month Day Time in 24h clock Value and Unit Advanced Settings During normal functions not Datalogging press and hold the SET Button for 2 seconds to enter the Advanced Setting mode Press the Next But ton scroll through eight main functions shown on the lower display SdF SD memory card Format dAtE Set clock time Year Month Date Hour Minute Second SP t Set sampling time Hour Minute Second HSPt Set sampling time for peak record mode PoFF Auto power OFF management bEEP Set beeper sound ON OFF unit Set the measurement unit dEC Set SD card Decimal character ESC Exit Advanced Settings While in the Advanced Setting function press the Esc Button to exit and to return to normal functioning SD memory card Format Please Note Formatting the SD card erases all data from that SD card 1 When the lower display shows Sd F use the Up or Down Buttons to select yES format the SD card or no do not format the SD card 2 To format your SD card select yES and press the Enter Button The Display will show yES Enter to confi
4. gt 5 D 6020 Force Gauge Datalogger FORCE GAUGE Instruction Manual www reedinstruments com Distributed by MicroDAQ com www microdaq com reed 603 746 5524 Table of Contents FOALUNCS nrin erer a aea penanda ei n E rasa READ Specifications Instrument Description Operating Instructions Alarm Beep fr sssseerereseererese Peak Hold Measurement Backlight ON OFF cccecceee Datalogger sversi Auto Datalogger Manual Dataloggel cccc Peak Hold DataloQQer ocrsisacieates ienna aei CHECKING INE TMC sisi hii in Aa breakin Check Sampling Time Information SD Card Data SMuCture sedisse re AET EARE Data Transfer from SD card to COMpUter ssssssssserssrerreereeeeee Advanced Settings 15 coccsu ect caceevecidccneticendeeesetenctvnsecveunssccvecsceieens SD MOMOPY Car Format arees iieiea eie eer inan IEE SEM CIOCK TMG piierne a e a E NEEN E Set sampling UNG cst eae Greate e RA Set sampling time Peak Mod 8 ssssssssssesrsesrsrernssrrneersrernserrneees Auto power OFF managemMent ssresrssieriesirrrrerrrreernnirnensareene Set Beeper Sound ON OFF esscesssescseseecsssrecesaresenetersnaseneneeenaeees Setting the Decimal point on the SD Card Set Measurement Unit srei prenan p r EEEREN PC Serial Interfaces System ReSet eccecceeeeesseeeeeeseeeeeeeeeeensseeeeeeeees Battery Replacement ccccnseeeccnescheceeseseeeeetedescnte cuecsdeedee cies skanis Distribute
5. accessories 0 2 0 6 seconds 1 second to 9 hours 10mS 500mS 0 4mm Max Max full capacity SD memory card 1 GB to 16 GB USB RS232 PC computer interface 0 50 C 0 122 F Less than 85 R H UMS3 AA 1 5 V x 6 batteries 6509 1 43Ib 215 x 90 x 45mm 8 5 x 3 5 x 1 8 Flat head adapter Hook adapter Cone head adapter Chisel head adapter 120mm extension rod and one Carrying case 2G SD Card SD 2GB Test stand FS 1001 Wedge grip WG 01 USB cable USB 01 RS232 cable UPCB 01 Data Acquisition Software SW U801 WIN Visit us at www reedinstruments com for more information on our Optional Accessories or e mail us at info reedinstruments com For service on this or any other REED product or information on other REED products contact REED Instruments at info reedinstruments com Distributed by MicroDAQ com www microdaq com reed 603 746 5524 Instrument Description Sensor Display Power amp Backlight Button Up amp Zero Button Fast Slow amp ESC Button Peak amp Enter Button Display Reverse amp Down Button Time amp Set Button 9 Logger amp Sampling Check Button 10 USB RS232 Output 11 Reset Button 12 AC DC 9V Power Adapter Input Socket 13 Mounting Holes 14 Battery Compartment Cover 15 Flat head Adapter 16 Cone Adapter 17 Chisel Adapter 18 Hook Adapter 19 120 mm Extension Rod 20 SD card slot ALO OP ONS Sa
6. ber and count down to zero while saving the data to the SD card Checking the Time During normal functions not Datalogging press the Time Check Button and the lower LCD display will show the Year Month Date Hour Minute Check Sampling Time Information During normal functions not Datalogging press the Sampling Button and the lower LCD display will show the Sampling Time Information SD Card Data Structure 1 The first time the SD card is used in the meter the SD card will generate a folder FGBO1 2 The first time you use the Datalogger in the folder FGB01 a new file name FGBO1001 XLS will be created The Datalogger will use this file until the Data has reached to 30 000 rows The meter will then will generate a new file with a subsequent number for ex ample FGB01002 XLS 3 The folder FGBO1 can hold 99 XLS files When that number has been reached the meter will then will generate a new folder with a subsequent number for example FGB02 Max number of FGB folders is 10 Data Transfer from SD card to Computer EXCEL Software 1 After Datalogging remove the SD card from the SD card slot 2 Plug in the SD card into the Computer s SD card slot or insert the SD card into the optional SD card adapter and connect to your Computer Turn your computer on and a folder will appear on your desktop representing you SD card continued Raa mreedinstruments cm 9 Distributed by MicroDAQ com www microdaq com reed 603
7. d by MicroDAQ com www microdaq com reed 603 746 5524 Features Data record in Normal Mode or Peak Hold Mode e Sampling time Normal Mode 1sec 8h Peak Hold 10ms 500ms e Memory capacity Normal Mode 1GB 16 GB Peak Hold 1000 data no max Display units in Kg Ib Newton e Tension and compression capability Full capacity zero tare control capability Fast Slow response time e Positive or reverse display direction e Over load protection Real time SD memory card datalogger with a built in clock and calendar e No extra software needed just plug the SD card into the computer and it downloads directly to EXCEL e SD card capacity 1 GB to 16 GB Easy to read LCD with backlight e Auto power off or manual power off High accuracy microcomputer circuit e Power by UM3 AA 1 5 V x 6 batteries e USB RS232 Computer interface Specifications Circuit Custom microprocessor LSI circuit Display 52mm x 38mm LCD with backlight Units Kg lb Newton Measuring Capacity 20 00Kg 44 10Ib 196 12N Min Display 0 01Kg 0011b 0 02N Accuracy 0 5 2 digits within 2345 C Raa mreedinstruments som 3 Distributed by MicroDAQ com www microdaq com reed 603 746 5524 Sampling Time Auto Sampling Time Peak Hold Full Scale Deflection Zero Tare Control Memory Card Data Output Operating Temperature Operating Humidity Power Supply Weight Dimensions Includes Optional
8. ix DC 1 5 V batteries UM3 AA Alkaline heavy duty 4 Make sure the battery cover is properly secured after changing the battery For service on this or any other REED product or information on other REED products contact REED Instruments at info reedinstruments com www reedinstruments com 14 Distributed by MicroDAQ com www microdaq com reed 603 746 5524 Notes REED www reedinstruments com 15 Distributed by MicroDAQ com www microdaq com reed 603 746 5524 Notes REED www reedinstruments com 16 Distributed by MicroDAQ com www microdaq com reed 603 746 5524
9. lect the value yES Enable Auto Power Off or no Disable Auto Power Off 2 After selecting yES or no press the Enter Button to save the setting as the default To exit Advanced Settings press the Esc Button www reedinstruments com 11 Distributed by MicroDAQ com www microdaq com reed 603 746 5524 Set Beeper Sound ON OFF 1 When the lower display shows bEEP use the Up or Down But tons to select yES Beeper Sound is ON or no Beeper Sound is OFF 2 After selecting yES or no press the Enter Button to save the setting as the default To exit Advanced Settings press the Esc Button Setting the Decimal point on the SD Card 1 When the lower display shows dEC use the Up or Down Buttons to toggle between bASIC Decimal Point or Euro Deci mal Point 2 After the Decimal point character has been selected press the Enter Button to save the setting as the default To exit Advanced Settings press the Esc Button Set Measurement Unit 1 When the lower display shows unit use the Up or Down Buttons to adjust the measurement unit Kg Ib or N 2 After the Measuring Unit is selected press the press the Enter But ton to save the setting To exit Advanced Settings press the Esc Button ESC When the lower display shows ESC press the Enter Button to finish the Advanced Settings procedures and return to
10. n measure the peak value of force both of tension amp com pression operation While taking a measurement as described above press the Peak Button to switch to Peak Hold Mode The Display will show the PEAK indicator and during measurement the Display will freeze on the Peak hold value Alarm beeper If the measuring value is over 20 00 Kg an internal buzzer will sound Raa mreedinstruments com 6 Distributed by MicroDAQ com www microdaq com reed 603 746 5524 Backlight ON OFF After powering the meter ON the LCD Backlight will turn on automati cally While taking measurements press the Backlight Button and the LCD Backlight will turn off Press the Backlight Button once again to turn the LCD Backlight back ON Datalogger Preparation Before Executing the Datalogger Function 1 Insert the optional SD card into the SD card socket 2 Before you use an SD card with this meter for the first time it is recommend to format the SD card See Advanced Settings section of this manual for instructions 3 If this is the first time the meter is used you need to adjust the clock See Advanced Settings section of this manual for instruc tions 4 Now you need to set the decimal format The numerical data struc ture downloaded to the SD card is defaulted used the as the decimal for example 20 6 1000 53 But in certain countries the is used as the decimal point for example 20 6 1000 53
11. rm Press the Enter But ton to confirm Raa mreedinstruments com 10 Distributed by MicroDAQ com www microdaq com reed 603 746 5524 Set Clock Time 1 When the lower display shows dAtE press the Enter Button Use the Up and Down Buttons to adjust the Year After the desired value is set press the Enter Button to adjust the Month Date Hour Minute and Second values 2 After all the time values have been set the screen will jump to SD card Decimal character setting screen To exit Advanced Set tings press the Esc Button Note After the time value is set the internal clock will run even when the power is off if the battery is under normal conditions Set sampling time 1 When the lower display shows SP t use the Up or Down Buttons to adjust the value to either 0 1 2 5 10 30 60 120 300 600 1800 or 3600 seconds 2 After the Sampling value is selected press the press the Enter But ton to save the setting as the default To exit Advanced Settings press the Esc Button Set sampling time Peak Mode 1 When the lower display shows HSPt use the Up or Down But tons to adjust the Sampling Time value between 10mS and 500mS 2 After the Sampling value is selected press the press the Set Button to save the setting To exit Advanced Settings press the Esc But ton Auto power OFF management 1 When the lower display shows PoFF use the Up or Down But tons to se
12. sition Number press the Down Button and the lower position number will flash on the display Press the Up or Down Buttons to set the Position Number 1 to 99 to help identify the measurement location The lower Display will show P x x 1 to 99 After the position number is selected press the Enter Button to confirm 3 Stop Datalogging press the REC Button for 2 seconds and the REC symbol will disappear indicating the Datalogging function has stopped Peak Hold Datalogger 1 Install the meter on to the optional test stand and turn on the meter Press the Peak Button and the Display will show PEAK amp FAST 3 Press the Zero Button to set the Zero Value Press the Logger Button and the screen will display DATA RECORD while the sampling time value in ms will appear on the bottom of the screen The meter is now ready for Peak Hold Datalogging 5 If the applied force value is gt 0 2 Kg 1 full capacity the measurement value and sampling period will save to the internal memory circuit in sequence To change the Sampling Time please see the Advanced Settings section of this manual continued iass reedinstrumentscm 3 Distributed by MicroDAQ com www microdaq com reed 603 746 5524 6 When the peak value is obtained the indicator DATA RECORD will disappear while the PEAK indicator and the Peak Value will remain The bottom of the Display will show the data record num
13. the normal measuring screen www reedinstruments com 12 Distributed by MicroDAQ com www microdaq com reed 603 746 5524 PC Serial Interface The instrument features an PC output via 3 5 mm terminal The connector output is a 16 digit data stream which can be utilized to the user s specific application An USB RS232 lead with the following connection will be required to link the instrument with the PC serial input Meter 3 5mm Jack Plug PC 9W D Connector Center Pin Pin 2 Ground Shield Pin 5 The 16 digit data stream will be displayed in the following format D15 D14 D13 D12 D11 D10 D9 D8 D7 D6 D5 D4 D3 D2 D1 DO DO End Word D1 to D4 Upper Display reading D1 LSD D4 MSB D5toD8 D5 D6 D7 D8 D9 Decimal Point DP for display 0 No DP 1 1 DP 2 2 DP 3 3 DP D10 D10 0 D11 D11 0 D12 D12 0 D13 D13 0 D14 D14 0 D15 Start Word Raa mreedinstruments com 13 Distributed by MicroDAQ com www microdaq com reed 603 746 5524 System Reset If an error occurs press the Reset Button with a Pin If the Reset Button does not fix the error please send in the unit to our Calibration Lab for repair E mail info reedinstruments com for more information Battery Replacement 1 When the left corner of LCD display shows cx it is necessary to replace the battery 2 Loosen the screws of the Battery Cover and remove 3 Remove the batteries and replace with S