Home
IPC-613
Contents
1. 1 613 2U e Server Chassis Copyright Notice This document is copyrighted June 2000 by Advantech Co Ltd All rights are reserved Advantech Co Ltd reserves the right to make improvements to the products described in this manual at any time without notice No part of this manual may be reproduced copied translated or transmitted in any form or by any means without the prior written permission of Advantech Co Ltd Information provided in this manual is intended to be accurate and reliable However Advantech Co Ltd assumes no responsibili ty for its use nor for any infringements of the right of third parties which may result from such use Acknowledgments IPC 613 is trademarks of Advantech Co Ltd Note The information in this document is provided for reference only Advantech does not assume any liability arising out of the direct or indirect use of the information or products described herein This manual is subject to change without notice Part No 2002061300 lst Edition Printed in Taiwan June 2000 Chapter 1 Chapter 2 Appendix A Appendix B Contents General Information ccccccesesssseeeeeeeeeeeeneeeees 1 1 1 1500066000 ses 1 1 2 Specificationsysssuns sense ae 1 123 Dimensions REE eee 2 System SOUP scene anna decanted 3 2 1 REMOVING the COVER nee 3 2 2 DIVEBaYas een 4 23 Installing A Motherboard zu aed eeeneaceetrecces are 5 2 4 Installing the Riser Ca
2. Dimensions W x D x H 482 x 595 x 88 mm 19 x 23 4 x 3 5 e Interior paint color Black 4C 2X brushed finish Ni Power supply Output rating 300 W e Input rating 100 200 Vo e Output voltage 3 3 V 16 A 5 V 26 A 12 V 10 A 5 V 0 25 A 12 V 1 A 45 Vi 15A Minimum load 5 V 1 A 12V 0 5 A e MTBF 50 000 50 C e Safety CE UL CUL Environmental specifications Operating temperature 0 45 C 32 113 F Relative humidity 10 95 40 C non condensing e Safety UL CE approved e CE compliant IPC 613 User s Manual 1 imensions 1 3 D WM 9 WWMM WWMM WWM ol 7 L WWW ol 7 WWMM Unit mm inches Figure 1 1 IPC 613 dimensions IPC 613 User s Manual 2 Chapter 2 System Setup The following procedures are provided to assist you in installing drives and plug in cards into the IPC 613 2 1 Removing the Cover 1 Unscrew the screws at the rear side of the chassis 2 Slide the upper cover backwards 3 Lift up the upper cover to open the chassis Figure 2 1 Upper cover removing IPC 613 User s Manual 3 2 2 Drive Bay The IPC 613 supports four hard disk drives one CD ROM drive and one floppy disk drive There are two types of the IPC 613 available IPC 6
3. DISCLAIMER This set of instructions is given according to IEC 704 1 Advantech disclaims all responsibility for the accuracy of any statements contained herein IPC 613 User s Manual 11 B 2 German Wichtige Sicherheishinweise 12 10 11 12 13 14 15 Bitte lesen Sie Sich diese Hinweise sorgfaltig durch Heben Sie diese Anleitung f r den sp teren Gebrauch auf Vor jedem Reinigen ist das Ger t vom Stromnetz zu trennen Verwenden Sie Keine Fl ssig oder Aerosolreiniger Am besten dient ein angefeuchtetes Tuch zur Reinigung Die Netzanschlu steckdose soll nahe dem Ger t angebracht und leicht zug nglich sein Das Ger t ist vor Feuchtigkeit zu sch tzen Bei der Aufstellung des Ger tes ist auf sicheren Stand zu achten Ein Kippen oder Fallen k nnte Verletzungen hervorrufen Die Bel ftungs ffnungen dienen zur Luftzirkulation die das Ger t vor berhitzung sch tzt Sorgen Sie daf r da diese ffnungen nicht abgedeckt werden Beachten Sie beim Anschlu an das Stromnetz die Anschlu werte Verlegen Sie die Netzanschlu leitung so da niemand dar ber fallen kann Es sollte auch nichts auf der Leitung abgestellt werden Alle Hinweise und Warnungen die sich am Ger ten befinden sind zu beachten Wird das Ger t ber einen l ngeren Zeitraum nicht benutzt sollten Sie es vom Stromnetz trennen Somit wird im Falle einer berspannung eine Besch digung vermieden Durch die L ftungs ffnungen d rf
4. the alarm board inside the chassis TO TEMP Sensor SW1 TEMP SEL swi BE 1 2 TEMP TEMP Fe OFF OFF 65 C OFF ON 55 C ON om we o ON ON 75 C PF RSTRAID LED FAN1 FAN2 FAN3 POWER TO LED BOARD TO RAID CONTROLLER Reserved ALARM RESET POWER FAULT Figure 2 5 Temperature Setting abrir HER Figure 2 6 System monitoring alarm board IPC 613 User s Manual 7 8 IPC 613 User s Manual Appendix A Riser Card Two PCI expansion slots at 32 bit 33 MHz Part Number 9686613000 3 F 2 2 S 3 a 147 97 58 26 145 17 56 37 133 066 52 39 117 066 46 09 72 106 28 39 3 68 286 26 88 3 55 586 21 88 3 R 6 875 2 71 o 0 0 0 es TR ols Sn Sk Unit mm inches IPC 613 User s Manual 9 10 IPC 613 User s Manual Appendix B Safety Instructions B 1 English 1 2 3 10 11 12 13 14 15 Read these safety instructions carefully Keep this user s manual for later reference Disconnect this equipment from any AC outlet before cleaning Do not use liquid or spray deter gents for cleaning Use a damp cloth For pluggable equipment the power outlet must be installed near the equipment and be easily accessible Keep this equipment away from humidity Put this equipment on a reliable surface during installation Dropping it or letting it fal
5. 13 and IPC 613 SCA The IPC 613 SCA provides a SCA 2 backplanes and therefore support four hot swap hard disk drives Please notice that the IPC 613 support two 3 5 1 height SCSI hard disk drives with 80 pin SCA 2 connecotrs and two 3 5 1 6 height SCSI hard disk drives with 80 pin SCA 2 connectors In order to install the hard disk drives in the chassis please follow the following procedures 1 Unscrew the screws on the hard disk trays and pull them out 2 Put hard disk drives in the hard disk racks and fasten them with screws 3 Slide the hard disk racks into the drive bay Figure 2 2 Hot swap hard disk drive bay 4 IPC 613 User s Manual 2 3 Installing A Motherboard The IPC 613 support ATX motherboards Please contact Advantech for recommended motherboard solutions lt N N N N N N s gt N S Figure 2 3 IPC 613 with server motherboard IPC 613 User s Manual 5 2 4 Installing the Riser Card One riser card is shipped with the IPC 613 This riser card can support two PCI expansion slots Please refer to Figure 2 4 to install the riser card Figure 2 4 Riser card on the motherboard 6 IPC 613 User s Manual 2 5 Temperature Setting If the chassis interior temperature exceeds 65 C 149 F default setting the LED changes color from green to red There will be audio alarm as well The LED remains red until the temperature goes below 63 C Temperature also can be selected SW1 on
6. en niemals Gegenst nde oder Fl ssigkeiten in das Ger t gelangen Dies k nnte einen Brand bzw elektrischen Schlag ausl sen ffnen Sie niemals das Ger t Das Ger t darf aus Gr nden der elektrischen Sicherheit nur von authorisiertem Servicepersonal ge ffnet werden Wenn folgende Situationen auftreten ist das Ger t vom Stromnetz zu trennen und von einer qualifizierten Servicestelle zu berpr fen a Netzkabel oder Netzstecker sind besch digt 0 Fl ssigkeit ist in das Ger t eingedrungen c Das Ger t war Feuchtigkeit ausgesetzt d Wenn das Ger t nicht der Bedienungsanleitung entsprechend funktioniert oder Sie mit Hilfe dieser Anleitung keine Verbesserung erzielen e Das Ger t ist gefallen und oder das Geh use ist besch digt f Wenn das Ger t deutliche Anzeichen eines Defektes aufweist Bitte lassen Sie das Ger t nicht unbehehrt hinten unter 20 C 4 F oder oben 60 C 140 F weil diesen Temperaturen das Ger t zerst ren k nten Der arbeitsplatzbezogene Schalldruckpegel nach DIN 45 635 Teil 1000 betr gt 70dB A oder weiger DISCLAIMER This set of instructions is provided according to IEC704 1 Advantech disclaims all responsibility for the accuracy of any statements contained herein IPC 613 User s Manual
7. l could cause damage The openings on the enclosure are for air convection Protect the equipment from overheating DO NOT COVER THE OPENINGS Make sure the voltage of the power source is correct before connecting the equipment to the power outlet Position the power cord so that people cannot step on it Do not place anything over the power cord All cautions and warnings on the equipment should be noted If the equipment is not used for a long time disconnect it from the power source to avoid damage by transient overvoltage Never pour any liquid into an opening This could cause fire or electrical shock Never open the equipment For safety reasons the equipment should be opened only by qualified service personnel If any of the following situations arises get the equipment checked by service personnel a The power cord or plug is damaged b Liquid has penetrated into the equipment c The equipment has been exposed to moisture d The equipment does not work well or you cannot get it to work according to the installation reference guide e The equipment has been dropped and damaged f The equipment has obvious signs of breakage DO NOT LEAVE THIS EQUIPMENT IN AN UNCONTROLLED ENVIRONMENT WHERE THE STORAGE TEMPERATURE IS BELOW 20 C 4 F OR ABOVE 60 C 140 F THIS MAY DAMAGE THE EQUIPMENT The sound pressure level at the operator s position according to IEC 704 1 1982 is equal to or less than 70 dB A
8. rd a are ee 6 2 5 Temperature Setting zes nee 7 Riser Card ine nei 9 Safety Instructions u 11 Bi rel 11 B 2 German Wichtige Sicherheishinweise 12 Figure 1 1 Figure 2 1 Figure 2 2 Figure 2 3 Figure 2 4 Figure 2 5 Figure 2 6 Figures IPC 613 dimensions Upper cover removing Hot swap hard disk drive bay IPC 613 with server motherboard Riser card on the motherboard Temperature Setting System monitoring alarm board Chapter 1 General Information 1 1 Introduction 1 2 The IPC 613 is a 2U high rack mount e Server chassis for high density internet services Engineered for service providers and enterprises the IPC 613 s rack mount 2U form factor is best for stacking servers as services grow The IPC 613 is designed to accommodate ATX motherboards With various configuration possibilities the IPC 613 provides the flexibility and high performance at the same time Specifications e Construction Heavy duty steel e Disk drive capacity Four optional hot swap 3 5 hard disk drive space one 5 25 CD ROM drive and one 3 5 floppy disk drive e Expansion slots Two PCI expansion slots on the PCI riser card Indicators LEDs for power fan and temperature e Controls Momentary power switch and alarm reset switch on front panel e Cooling fan Three 38 6 CFM cooling fans 115 8 CFM in total e Weight 10 kg 22 Ibs
Download Pdf Manuals
Related Search
Related Contents
Samsung Samsung M320 Citrix Systems Switch SDX 11500 User's Manual Q-Wash 419Z-LED User Manual ミニマックス 取扱説明書(PDF) Copyright © All rights reserved.