Home
Postage UK with ISP
Contents
1. on this link www elane net PortoPlus PostageUK postageUK_orderform htm 3 Download and install the latest version of http www elaneinternational com PortoPlusDownload PostageUK PostageUK PCProgram msi 4 Close all other windows or programs until your scale is successfully updated Make sure that you are also connected to the Internet before proceeding 5 Connect your scale to any available serial port of your computer and run Postage UK PC Program It will be automatically detected what port in your computer the scale is connected to 6 The PC Program will detect for a new version of your scale s software If you have paid for an update you can avail of this new version and the PC Program will update your scale automatically 7 Please wait for the entire process to finish ensuring that your scale is updated properly 8 After a successful scale software update your scale will restart New rates and or services now apply to your Postage UK with ISP scale 9 If you have problems regarding the scale software update please send email to helpdesk elane net
2. will require servicing If the scale is kept in a colder or warmer environment to the room in which calibration is to take place it must be left for long enough to achieve the same temperature before calibration takes place To calibrate the scale connect the mains adapter to the scale and mains power supply The scale will turn on and display Elane Press the UK Special Delivery key while this appears in the display The scale will prompt you to remove any weights present on the platform After the weights have been removed it then prompts you to place a 1 kilogram weight on the platform After doing so the scale will automatically recalibrate itself When it is done the scale will again prompt you to remove the 1 kilogram weight and will then restart automatically once the weight is removed SOFTWARE UPDATES Updating your scale with its latest software which may include new rates and or additional services can be done using the Postage UK PC Program This application program can be downloaded for free Your scale comes with an interface cable that can be used to connect to your computer Please follow these steps in updating the software of your scale 1 Register your Postage UK with ISP scale online only if you have not registered your scale before You may register your scale on this link www elane net PortoPlus PostageUK postageUK _registration htm 2 Purchase a software update for Postage UK with ISP You may purchase an update
3. Tare Feature Press the ON OFF key with the item to be tared on the platform and the weight display will go to 0 indicating that the weight has been tared or set to zero This is useful for weighing items ina container To clear tare remove the weight the display will read a negative number Press the ON OFF key again and the weight display will go to 0 Maximum tare value is up to 500 grams only F G a The Scale will display Overload if any weight over 2010 grams including tare weight is placed on the platform b The Scale will display Over on the postage display if any weight over 2000 grams including tare weight is placed on the platform c The Scale will display No Service when the user attempts to enable a special service in a service where it is not applicable d The Scale will display N A if current weight exceeds the maximum allowed weight for the service selected USER CALIBRATION Under exceptional circumstances it is possible for the scale to lose accuracy and may need re calibration The load cell of this precision scale is protected against overloaded weight that is applied slowly but overload caused by dropping the scale or dropping something heavy on the scale may cause the scale to require re calibration CAUTION Please do not attempt any calibration by yourself unless you have a 1 kilogram weight available If a 1 Kg weight is not used the scale will not operate correctly and
4. USER S MANUAL POSTAGE UK Internet Rate Download Enabled Scale BASIC SERVICES AVAILABLE First Class Mail Letter Large Letter Packet Stamped and Metered Second Class Mail Letter Large Letter Packet Stamped and Metered Special Delivery 9AM 50 1000 2500 Stamped and Metered Special Delivery Next Day 500 1000 2500 Stamped and Metered International Airmail Letter Europe and Outside Europe Zone 1 amp 2 Stamped and Metered o International Surface Mail Letter O O OOO SPECIAL SERVICES AVAILABLE Recorded Delivery International Signed For International Signed For with Additional Compensation AirSure AirSure with Additional Compensation Saturday Guarantee for Special Delivery services OTO O 0 OO O SPECIAL FEATURES Tare Function Domed Keyboard for Tactile Response Strain Gauge Loadcell Technology Scale Software Updatable thru Web Pons BASIC TECHNICAL DETAILS Maximum Capacity 2000g Including Tare Accuracy 1 gram Power Supply 9 volt AC adapter UL rated Power Consumption Approx 400mW Minimum add Weight 1 gram Minimum Weight 1 gram Dimensions Weight Overall 734 x 51 2 x 21 4 Platform 5 x 5 opens for flats Unit Weight 1 Ib 2 8 oz Packaged Weight 2 lbs 4 oz Tare 500g A START UP INSTRUCTIONS Place the scale on a flat surface Plug AC adapter included into the Postage UK scale port at back of unit and then into ma
5. between Airmail Letter Europe Airmail Letter Rest of the World Zone 1 and Airmail Letter Rest of the World Zone 2 services Press the Metered Stamped key to toggle between Stamped and Metered Airmail Letter Europe Airmail Letter Rest of the World Zone 1 and Airmail Letter Rest of the World Zone 2 services 5 Outside Europe Surface Mail Press this key for International Surface Mail Letters being sent Outside of Europe D SPECIAL SERVICES 1 Recorded Delivery Press this key to add on the fee for Recorded Delivery to the basic postage of 1 Class or 2 Class services Pressing this key again will cancel the service 2 International Signed For 1 amp 2 Press this key once to add on the fee for the International Signed For service to the basic postage for Airmail or Surface Mail Pressing it again will add the additional compensation fee for International Signed For Third press of this key will cancel the service 3 AirSure 1 amp 2 When in Airmail services press this key once to add on the fee for the AirSure service to the basic postage Pressing it again will add additional compensation fee for the AirSure service Third press of this key will cancel the service 4 Saturday Guarantee Special Delivery When in Special Delivery services press this key again to add on the additional fee for guaranteed Saturday delivery for items posted on a Friday Pressing this key again will cancel the service E OTHER FEATURES
6. ins power supply Press ON OFF key to turn on the scale When the scale has concluded its self test the scale is ready for weighing and calculating postage rates The default service is UK 1 Class Letter Stamped NOTE For larger items that obscure the display raise the angled platform prior to turning on the Scale DO NOT FORCE OPEN PAST ITS DESIGNED ANGLE OF APPROX 70 DEGREES To display the 8 digit serial number of the scale press Letter Large Letter Packet key during the self test sequence The serial number will be required when ordering new software updates for the scale User calibration at 1kg is available Please refer to the section below for further details B KEYBOARD LAYOUT Postage UK pe UK 4 Europe 6 internet Rate Download Enabled UK 2 Zone1 7 signedfor 2nd Class Zone2 8 1 amp 2 9 saturday uk 3 Outside Europe guarantee special 4 airsure delivery Surtace ar Metered Large Letter TARE Sta d Packet nee 2000g d 1g C POSTAL SELECTIONS 1 1 Class Mail Letter Large Letter Packet Press this key to select 1 Class Mail Service By default pressing this key will select Stamped Class Letter 4s Press Letter Large Letter Packet key to toggle between 1 Class Letter 1 Class Large Letter and 1 Class Packet services 4 Press the Metered Stamped key to toggle between Stamped 1 Class and Metered Class services The current weight limits of 1 C
7. lass Mail are as follows 1 Class Letters 100 grams Class Large Letters 750 grams Class Packets Up to scales maximum capacity 4st 4 If the item being weighed exceeds the maximum weight limit of the selected 1 Class Mail service N A will appear in the display 2 Class Mail Letter Large Letter Packet Press this key to select 2 Class Mail Service By default pressing this key will select Stamped 2 Class Letter Press the Letter Large Letter Packet key to toggle between 2 Class Letter 2 Class Large Letter and 2 Class Packet services Press the Metered Stamped key to toggle between Stamped 2 Class and Metered 2 Class services The current weight limits of 2 Class Mail are as follows 2 Class Letters 100 grams 2 Class Large Letters 750 grams 2 Class Packets 1000 grams If the item being weighed exceeds the maximum weight limit of the selected 2nd Class Mail service N A will appear in the display 3 UK Special Delivery Press this key to toggle between Special Delivery 50 Special Delivery 1000 and Special Delivery 2500 compensation rates The rates for 9AM and Next Day deliveries are automatically displayed alternately within a time interval of about 2 seconds Press the Metered Stamped key to toggle between Stamped Special Delivery and Metered Special Delivery services 4 Airmail Europe Zone 1 Zone 2 Press this key to toggle
Download Pdf Manuals
Related Search
Related Contents
A care Copyright © All rights reserved.
Failed to retrieve file