1. then set the Broker IP Address and click the Activate button Once it is done activating click the Done button to return to the main page Enter the kw hour rate that is being charged for your electrical service This is used in the calculation when the hr units are being displayed on the main page If you want to receive alert emails set the following e Set Alert Email Address to the email that you would like the alert to go to This could be an email or text address e Set SMTP Username to your email address e g e Set SMTP Password to your email password e g 16 character password which was previously generated e Set SMTP Server to your email server e g smtp gmail com e Click Activate SMTP Settings e Press the Done button to return to the main page Note It is recommended to set up a separate account for sending alerts The document assumes that a Gmail SMTP account will be used This account must enable 2 Step Verification and have an app password generated To set up 2 Step Verification follow these steps ee ae Sign in to My Account In the Sign in amp Security section select Signing in to Google Choose 2 Step Verification This will bring you to the 2 Step Verification settings page You will then see a step by step guide which will help you through the setup process Next you will need to generate an app password 1 ae em Visit your App passwords page You may be asked to sign in
2. Grid Frequency The trend chart settings dialog seen in Figure 5 gives you the ability to Fr export data in CSV format Click the icon to close the trend chart settings Use the a ae to zoom inor the button to zoom out of the trend chart 21 o jo j a f ee Figure 5 Trend Chart Settings Note Web Client screens may have a slightly different appearance 11 The following describes the assigned node and input configuration settings a Status Enterprise Runtime fs Figure 6 Configure Assigned Node Node Configuration Node Name Description A text field which gives the user the ability to set a description of the node Stale Period A visual alert will occur on the main page if the sensor hasn t reported within the set time period Trend Chart Y Axis Min and Max Allows the user to modify the scale of the Y Axis on the trend chart 12 For each Analog sensor the user can set the following Input Configuration Input Enabled Allows the user to enable or disable the sensor Sensor Label A text field which gives the user the ability to set a label for the input Normal Range Min Allows the user to set the normal minimum range Normal Range Max Allows the user to set the normal maximum range Alert Enabled Min Max Enable or disable the visual and email alerts for the related min and max range values Yellow Alert Threshold Allows
3. the user to set the threshold for the yellow alert The yellow alert threshold is x ofthe Normal Range Min and Max values Note yellow Alerts only alert the user via the dashboard An email or text message does not get sent Voltage for hr math This is used in the calculation for the displayed units on the main page Power Factor This is used in the calculation for the displayed units on the main page Click the Done button when completed UNINSTALLING DASHBOARD To uninstall the dashboard follow these instructions Close all Dashboard Clients Insert the B B USB memory stick into your PC Open the Removable Drive via Windows Explorer au pr Ww Select the uninstall cmd file right click and select Run as administrator Click Yes on the User Account Control Dialog Press any key to continue the installation on the command window See Figure 7 which shows the steps in which are part of the uninstall process 13 ci Administrator Delete B B Dashboard Figure 7 Uninstall Dashboard 14 APPENDIX A SET UP IIS WEB SERVER If you would like to run a web client perform these steps 1 Uninstall the Dashboard if you have already installed it Follow the Uninstalled Dashboard Section One must enable IIS prior to installing the dashboard WARNING Uninstalling the Dashboard will remove any historical data the system has stored 2 Open Windows Control Panel 3 Click the Programs an
4. Cellular mobile number email uscc net SMS mobile GE number mms uscc net MMS Verizon mobile number vtext com SMS mobile number vzwpix com MMS Virgin Mobile mobile number vmobl com SMS mobile number vmpix com MMS Esendex AU ES FR IE UK mobile number esendex net MobileMail RU mobile number mobilemail ru Table 1 Commonly used provider addresses CONFIGURE UNASSIGNED OR HIDDEN NODES All Unassigned Nodes are located in the Unassigned Nodes list box All nodes on your network will appear in the Unassigned Node list You can assign hide or delete a node To configure an Unassigned Node click it e Click Assign Node to assign the node Once a node is in the assigned state the node will start to display its sensor readings on the Dashboards main page e Click Hide Node to hide the node You might hide a node because you don t want to monitor it Once the node is in the hidden state the node no longer appears in the unassigned node list You can click the Show Hidden Nodes to view them e Click Delete Node to delete the node If you want to delete a node its best to remove it from your network To remove a node from the Unassigned Node list hide it All Hidden Nodes are located in the Hidden Nodes list box You can assign or delete a node To configure a Hidden Node click it e Click Assign Node to assign the node Once a node is in the assigned state the node will start to display its senso
5. Energy Monitoring Dashboard User Manual SMART TECHNOLOGY FOR ENERGY AUDITS nergy Monitoring Application Spectre Cellular Ethernet Gateway Intelligon E Ne des ard Wir les s SmartMesh IP Sensor Network BB SMARTWORX B B SMARTW RX International Headquarters B B SmartWorx 707 Dayton Road Ottawa IL 61350 USA Phone 815 433 5100 General Fax 815 433 5105 Website www bb smartworx com support bb smartworx com European Headquarters B B SmartWorx Westlink Commercial Park Oranmore Co Galway Ireland Phone 353 91 792444 Fax 353 91 792445 Document APP BNRG_Wzzard_Energy_Monitoring_Dashboard_R1_4615m CONTENTS OF PACKAGE The package includes e B B SmartWorx USB Flash Drive e Quick Start Guide SOFTWARE B B s Wzzard Energy Monitoring Platform featuring e Support for 1 32 nodes with 1 3 sensors per node e Real time data display selectable between Amps KW dollar cost e Historical function e User programmable high low limits for email SMS alerts e Ability to export data ABOUT THE ENERGY MONITORING DASHBOARD The Wzzard Energy Monitoring Application makes it simple to see the real time and historical electrical consumption of any individual machine or panel Data can be exported for further analysis Email or text message alerts can be sent when user configured high or low limits are exceeded in critical applications Installation costs are kept low using the Wzzard w
6. L to access the Dashboard via a web client From installed PC http localhost StatusEnterpriseGateway From a networked PC http lt IP address gt StatusEnterpriseGateway Note Only one web client can be logged in at a time 15 APPENDIX B DATABASE MAINTENANCE To improve response times the dashboard database should be periodically backed up and renewed To back up your database follow these steps 4 Close all Dashboard Clients Open Windows Explorer and go to C ProgramData BScada StatusEnterprise Copy the StatusEnterprise db3 file to a Backup folder Append a bak to this file To clean up and renew your database follow these steps 5 10 11 12 13 14 Run the Database Utility App found in the following location of the PC Start gt All Programs gt B Scada Enterprise Edition gt Status Enterprise gt Database Utility and right click and select Run as administrator Click Yes on the User Account Control Browse to the database C ProgramData BScada StatusEnterprise Status Enterprise db3 Click Connect Set Destination File Browse to the Backup folder and type StatusEnterprise db3 Click Save Click Renew DB Click Backup Once the backup has completed close the Database Utility Copy the new file located in the Backup folder to the original file location C ProgramData BScada StatusEnterprise When prompted to provide administrator permission click Continue 16 Conne
7. ction Settings Connection Provider SQLite Connector SQLite Connection Configuration to i M Database Note Locate the SQLite DB you wish to connect It is recommended to execute this prog with Administrator privileges Right click application then Run as administrator Backup Restore Scheduler Destination C ProgramData B Scada StatusEnterprise Backup backup1021 StatusE O Backup History r History Parameters O Full DB Backup Quick Select iia Renew D8 Connected B amp B SMARTWORX TECHNICAL SUPPORT Phone 1 800 346 3119 Monday Friday 7 a m to 5 30 p m CST Fax 815 433 5109 Email support bb smartworx com Web www bb smartworx com 17
8. d Features icon 4 Inthe left had navigation pane select Turn Windows features on or off 5 Expand the Internet Information Services feature and turn on the following circled features 6 Click OK 7 Follow the directions in the Dashboard Installation section to install the Dashboard Turn Windows features on or off To turn a feature on select its check box To turn a feature off clear its check box A filled box means that only part of the feature is turned on li Web Management Tools a 3 World Wide Web Services 3S Application Development Features Yj NET Extensibility vl ASP vii ASP NET JII ISAPI Extensions 7 J ISAPI Filters WrtTudes Y jy Default Document E ommon HTTP Features 9 v H 7 HTTP Redirection vb Static Content Performance Features a Securi u Basic Authentication a ien cate Mapping Authentication FIJ Digest Authentication IS Client Certificate Mapping Authentication FIJ Windows Authentication d Internet Information Services Hostable Web Core a V Media Features a Microsoft NET Framework 3 5 1 8 To allow remote access to the web client select the Firewall_Setup cmd file right click and select Run as administrator after the Dashboard installation is complete The following Internet Browsers were tested and recommended Chrome Version 43 0 x Mozilla Firefox Version 38 0 x Internet Explorer 11 0 x Use the following UR
9. ireless sensing platform The platform creates a self forming self healing wireless mesh network that eliminates the need for wires and requires no special skills to install Each Wzzard sensor node is powered by long life batteries Install the monitoring software on your Windows PC You can monitor the energy dashboard on that machine or configure it to serve web pages that you can monitor from any web browser on your network DASHBOARD INSTALLATION To install the dashboard Pre Requisite Windows PC with one of the following Operating Systems Windows 7 32 or 64 bit windows 8 1 32 or 64 bit Windows 10 32 or 64 bit The software will look for Microsoft NET Framework 4 5 or higher and if not present it will be installed Note If you want to access the dashboard from other devices using a web browser it is suggested not to use Windows 7 Before proceeding see Appendix A for setup Insert the B B USB flash drive into your PC Open the Removable drive via Windows Explorer Select the install cmd file right click and select Run as administrator Click Yes on the User Account Control Dialog B WOP H Press any key to continue the installation on the command window or press CTRL C or CTRL Break to exit the install 5 See Figure 1 which shows the steps which are part of the install process This will install the B B Dashboard Press CTRL C or CTRL BREAK to exit or any other key to continue Press any key to continue L
10. ook for Microsoft NET Framework v4 5 Installing B Scada Renaming Mimic Runtime Configure B Scada Add B B Dashboard Stopping B Scada Services Restarting B Scada Services Buccess Press any key to continue Figure 1 Install B B Dashboard 6 The Wzzard Monitor Short cut will appear on your desktop once the install has been completed To run the Dashboard 1 Double click the Wzzard Monitor shortcut on your Desktop 2 The main page of the dashboard is displayed The main page allows you to do the following a b A View the real time reading status of each assigned node analog sensor Configure the Units being displayed in Amps kw or hr by clicking the corresponding button View Hidden Nodes View Unassigned Nodes Modify the System Configuration o Ifthe gateway broker IP address has changed from the default this must be set on the System Configuration screen in order to see the nodes Manage Nodes Refresh the screen Wzzard Ba smaatwarx bb smartwor con Figure 2 Main Page with assigned nodes and alerts The System Configuration screen allows you to set the broker IP address the kw hour rate and the email address and SMTP server settings for sending email alerts Click the System Configuration Button on the Main screen 92 168 1 1 Figure 3 System Configuration If your gateway was setup on a network or is not using the default IP Address of 192 168 1 1
11. r readings on the Dashboards main page e Click Delete Node to delete the node If you want to delete a node it is best to remove it from your network To remove a node from the Unassigned Node list hide it MANAGE NODES If you click the Manage Nodes button it will allow the user to delete all nodes unassigned assigned and hidden There is also an option to delete one assigned node at atime Once the assigned node is deleted it will reappear in the unassigned nodes list if the node is still being reported by the broker ASSIGNED NODE STATUS TREND AND CONFIGURATION To view an Assigned Node s status and configuration click an assigned node which is located in the table on the main screen Figure 4 shows the current readings of the Analog Inputs the Internal Temperature and the Supply Voltage In the center of the screen it lists the BLE MAC address of the unit as well as the Node Description if it exists The trend chart displays the data based on the published data Sensor Values Oct 21 2015 Oct 21 2015 Oct 21 2015 12 05 32 PM Oct 21 2015 12 07 42 PM 12 09 52 PM 12 12 02 PM Oct 21 2015 Oct 21 2015 12 01 12 PM 12 03 22 PM Figure 4 Node Status and Configuration 10 The sensor settings are configurable by clicking the Configure button See the Configure Assigned Nodes section for more detail A The chart displays the historical data based on the published data Click the icon to edit the Duration and
12. to your Google Account At the bottom click Select app and choose the app you re using Click Select device and choose the device you re using Select Generate Follow the instructions to enter the App password the 16 character code in the yellow bar on your device Select Done Once you are finished you won t see that App password code again However you will see a list of apps and devices you ve created App passwords for If you want to receive alerts via text message on your mobile device you can set the Alert Email Address to a provider based address Below is a list of the commonly used provider addresses Check with your mobile service provider for updated addresses Alltel Wireless mobile number message Alltel com SMS amp MMS mobile number text wireless alltel com SMS mobile number mms alltel net MMS AT amp T Wireless mobile number txt att net SMS mobile number mms att net AT amp T Mobility formerly Cingular mobile number cingularme com mobile number mobile mycingular com Cricket mobile number sms mycricket com SMS mobile DEE number mms mycricket com MMS Sprint PCS mobile number messaging sprintpcs com SMS mobile number pm sprint com MMS Sprint Nextel mobile number page nextel com SMS mobile ee number messaging nextel com Rich Messaging Straight Talk mobile number VTEXT COM SMS mobile icine number mypixmessages com MMS mobile number tmomail net MMS U S