1. 13 SIMPLIFIED SERIAL 5 13 SETUP OF THE UNIT BY USING SS 10 TOOL 14 MAIN WINDONW tecti n ae e ta ton a d be e em Poo eie uds 14 PARAMETERS 2 15 CALL BACK RR 16 CALE BARRING 17 SMS OPTIONS eset dote s esa aes 18 NETWORK tiere IE 19 UPGRADE 955 106 FIRMWARE nnmnnn 20 TECHNICAL SPECIFICATIONS eene enne enne nihit 21 CONTACT DE TANS mc S 22 DOC NO SS 10C REV 02 Page 2 of 22 585 100 USER MANUAL 1 INTRODUCTION The purpose of the SS 10 C Fixed Cellular Terminal FCT is to provide a means of making telephone calls via the CDMA infrastructure ARCHITECTURE Least Cost Routing Least Cost Router n a j di im CDMA Tower Rural Telephony T b CDMA Tower DOC NO SS 10C REV 02 Page 3 of 22 2 1 2 3 2 2 SS 10C USER MANUAL FEATURES PHYSICAL FEATURES Matches to complex line impedance Power saving feed bridge Signal level indicator LEDs Busy indicator Network indicator SMA antenna connector CDMA module On Off switch allows Network Detach Power supply 300mA at 12 VDC RJ11 connector for telep
2. CDMA Click on COM then WL32SMPU 502 11 00 10 109 click on Refresh to do automatic baudrate detection aho Address Source File gt gt Displays the following IMSI VER IMSI Software Revision and Hardware type of the CDMA engine SS 10 Firmware revision number To update the firmware load the Firmware file from the File Menu UpLoad Firmware Use UpLoad Firmware button to load the Firmware into the unit Refer to the Upgrade Firmware section for the complete procedure Tick the Show Signal box for a visual and measured indication of the Show Signal signal strength DOC NO SS 10C REV 02 Page 14 of 22 SS 10C USER MANUAL 7 2 CALL PARAMETERS Click on SETUP to start with the setup of the SS 10 Call Parameters 10 Setup Call Parameters Call Back Call Baring SMS Options Network amp Security Call Setup Audio Parameters 2 10 Dialled Digit Count TX Level 2 Dial Timeout 5 0 Rx Level 2 Int Digit Count 15 Call setup Audio and Line levels can be changed in this window CLI Restriction Line Settings Hook Voltage 35V i 1 0 Off Hook Voltage 2b V Reversal on Answer Break Time 0 0 Ring Voltage 50V Update 55 10 Fetch settings amp Load Settings Call Setup Sets dial timeout in 10 of a second Dial Timeout This is the time taken before the call proceeds when numbers shorter than the total digit
3. telecoms our solutions your success oo 10C FIXED CELLULAR TERMINAL CDMA USER MANUAL SS 10C USER MANUAL Neotel Revision History Revision 01 Original document 08 October 2009 Revision 02 Added Call Back 10 June 2010 CONTENTS INTRODUCTION c e 3 4 PHYSICAL FEATURES ccrann 4 SOFTWARE FEATURES 4 MAINTENANCE FEATURES 4 Mlle gis em 5 FRONT VIEW e HR XR ER 5 REAR dear ettet te veh Herve 5 ec E 6 SEITABEE PAHAMETEBG tena 7 BASICSPTU P ttes ears uere Nereus 7 REPORTING SE CUP bn arb canna hanes 8 CALL DETAIL 8 AUTHORIZED USER sraoin eres rai IRA Toa vague 9 HARDWARE SETTINGSS 4 rient ed eee e E Ra e HR ERR ERR a PRI 9 NETWORK AND SECURITY 10 CALL BARRING ipee 1 CALI BACK ASTE Ee NN M oii 11 MISCELLANEOUS oeeie re aerea E EEE 11 SETUP INFORMATION e ice pa e a ee RES 12 5 weet ro ER
4. 7 3 CALL BACK 55 10 Setup Call Parameters Call Back Call Baring SMS Options Network amp Security Call Back 8825551234 Number Call back numbers can be 0825551234 added in this window NB In some cases the Abies Sra o network does not issue a command to disconnect a busy call If this is the case the call should be manually terminated when the busy tone is heard to allow for call back Total Records 1 Update 55 10 Fetch settings 9 Save Settings amp Load Settings Click on Add or Delete to enter or remove the number from the list Number The call back number to be added to the list When ticked the call back list will be ignored and any incoming call Allow Any Number number will be called back DOC NO SS 10C REV 02 Page 16 of 22 SS 10C USER MANUAL 7 4 CALL BARRING 55 10 Setup Call Parameters CallBack Call Barring SMS Options Network amp Security 83CCCC BARRED Number Type 083 BARRED v Require Allowed Numbers Call Barring Allow Incoming Calls Calls can be barred or allowed Enable Auto Call Termination L1 Call Duration h mm Total Records 1 Update 55 10 Fetch settings 9 Save Settings amp Load Settings Enter the first digits of the number needed to recognise the number type Select the Type as BARRED or ALLOWED Click on Add or Delete to enter or remove the number from the list If the block is
5. count are dialed Nominal value is 4 seconds Sets the total number of digits required before dialling alee It is recommended that this parameter is set to 10 Sets the total number of digits needed before dialling if an international Int Digit Count prefix 00 is detected Also invoked if a or is dialled as the first digit Hides the number of origin when a call is made to an external party CLI Restriction Note CLI is not supported for international calls Reversal Time Sets reversal time in 10 of a second Reversal on Answer Enables or disables Reversal on Answer Sets the break time 10 of a second Some PABX systems require Break Time current break to indicate that the call has terminated If it is not required then set this to O Audio Parameters TX Level Sets Audio Transmit level Nominal value is 2 RX Level Sets Audio Receive level Nominal value is 2 Line Settings On Hook Voltage The allowed range is from 20 to 40 volts Nominal value is 35 volts It can be set from 18 to 30 volts The nominal value is 25 volts This Off Hook Voltage allows power usage to be reduced during conversations which reduces heating in confined spaces The range is 40 to 60 volts The factory setting is 50 volts normally this setting will not require adjustment Ring Voltage DOC NO SS 10C REV 02 Page 15 of 22 SS 10C USER MANUAL
6. not ticked it will allow all the numbers that are not Require Allowed Numbers Allow Incoming Calls The SS 10 can be set to allow or ignore incoming calls Automatically terminates an outgoing call after a user defined Call Auto Call Termination uae Period DOC NO SS 10C REV 02 Page 17 of 22 7 5 SMS OPTIONS SMS Options The SS 10 can be set to send fault reporting via SMS to a required destination number It can authorise two users to control the unit via SMS Reporting Setup SS 10 USER MANUAL 55 10 Setup Call Parameters Call Back Call Baring SMS Options Network amp Security Reporting Setup Report Destination 27825551234 Report Identity Get IMSI 655131300000005 No Call report interval Routine Report interval SMS Control Info Authorised User 1 27825551234 Authorised User 2 Update 55 10 Fetch settings amp Load Settings Feed bridge voltages CDMA module voltage Number of failed calls Total duration of answered calls Report Destination Destination number for reports to be sent Country code to be included e g 27828221381 Report Identity Identity to be sent with report for identifying the unit Click on Get IMSI to retrieve the number from the unit or use any custom text as the identity No Call Report Interval A report will be sent if no calls have been made for this period of time Routine Report Interva
7. MANUAL 5 SETTABLE PARAMETERS 5 1 BASIC SETUP Parameter Description Notes Total Digit Count 01 Sets the total number of digits required before dialling It is recommended that this parameter is set to 10 Dial Timeout Sets dial timeout in 10 of a second Normally 4 seconds This is the time taken before the call proceeds when numbers shorter 02 than the total digit count or international digit count are dialled The dial timeout may be overridden by entering after the last dialled digit Polarity Reversal Signalling Sets reversal time in 10 of a second To enable reversal on answer 04 add 100 to the number input E g 04 20 sets the time to 2 0 seconds without reversal on answer and setting 04 120 sets it to 2 0 seconds WITH reversal on answer Please see Connection Alert Received 57 Break Pulse Signalling 05 Sets the break time in 10 S of a second Some PABX systems require a current break to indicate that the call has terminated The SS 10 can provide such a break If it is not required then set this parameter to O NB The CLI Restriction CDMA Sets the CLI Restriction status for outgoing calls Setting this value to network does 06 1 will hide the caller s identity and setting this value to 0 will display not currently the caller s identity support International CLI Transmit Levels Set transmit levels 1 4 2 normal NB Un
8. Office 23 Botha Avenue Lyttelton Manor Pretoria Gauteng South Africa Tel 27 12 664 4644 Fax 27 86 614 5625 E mail info sstelecoms com Postal address Postnet Suite 48 Private Bag x 1015 Lyttelton 0140 Pretoria Gauteng South Africa Sales Support South Africa E mail sales sstelecoms com United Kingdom E mail uksales sstelecoms com Technical Support E mail support sstelecoms com DOC NO SS 10C REV 02 Page 22 of 22
9. ation This feature allows an outgoing call to be automatically disconnected after a user defined time period Enter 0 to disable this feature or enter the desired time period in minutes to enable the feature 57 Connection Alert Received This feature is used in conjunction with Polarity Reversal Signalling 04 The CDMA network does not currently send a connection alert as default Connection is assumed on call setup A true connection alert can be requested from the network if circumstances demand this for PABX configuration etc Enter 0 if no connection alert is received default or enter 1 if arrangements have been made with the network to receive a connection alert 58 RUIM non RUIM Mode The SS 10C can be used with or without a RUIM card Enter 0 for RUIM mode or 1 for non RUIM mode default NB The unit will refuse network connection if the mode used does not match the set mode The unit will not function in non RUIM mode if a RUIM card is inserted and vice versa Please consider this before using the SMS programming functionality for this command NB The unit must be rebooted for the new setting to take effect DOC NO SS 10C REV 02 Page 10 of 22 SS 10C USER MANUAL 5 7 CALL BARRING Parameter Description Notes 60 Incoming Calls Prohibits incoming calls 0 allows incoming calls 1 Display Number Tab
10. e Extension or Trunk number to identify the SS 10 to which the CDR record belongs DOC NO SS 10C REV 02 Page 8 of 22 SS 10C USER MANUAL 5 4 AUTHORIZED USER Parameter Description Notes Authorised User 1 32 Gives authorisation to user 1 for controlling access to the SS 10 unit via SMS by entering the user s numbers Country code to be included e g 27828221381 Authorised User 2 33 Gives authorisation to user 2 for controlling access to the SS 10 unit via SMS by entering the user s numbers Country code to be included e g 427828221381 5 5 HARDWARE SETTINGS Parameter Description Notes On Hook Voltage 40 The On Hook voltage can be set with this command The allowed range is from 20 volts to 40 volts Nominal value is 35 volts Off Hook Voltage The Off Hook voltage is set using this command It can be set from 18 41 to 30 volts The nominal value is 25 volts This allows power usage to be reduced during conversations which reduces heating in confined spaces Peak Ring Voltage 42 Sets the peak ring voltage The range is 40 to 60 volts The factory setting is 50 volts normally this setting will not require adjustment DOC NO SS 10C REV 02 Page 9 of 22 SS 10C USER MANUAL 5 6 NETWORK AND SECURITY Parameter Description Notes 55 Power Down Time Time in minutes between forced network logoffs 56 Automatic Call Termin
11. f the unit is set to non RUIM mode and a RUIM is inserted and vice versa DOC NO SS 10C REV 02 Page 19 of 22 SS 10C USER MANUAL 8 UPGRADE SS 10C FIRMWARE Download Firmware The latest firmware for the SS 10 is available from http www sstelecoms com Connect unit to PC Connect the SS 10 unit to the PC by using a serial cable and make sure it is switched on Upgrade the Load the SS 10 Tool Program Firmware by using the SS 10 Tool Click on ComPort to select the required COM Set the BaudRate to 9600 From the File Menu choose Open and select the required Firmware file Click the UpLoad Firmware button to upload the new firmware to the unit Remove the serial cable from the unit after setup DOC NO SS 10C REV 02 Page 20 of 22 SS 10C USER MANUAL 9 TECHNICAL SPECIFICATIONS Housing Black powder coated Aluminum 147 x 90 x 26 mm POWER LED indicators IN USE NETWORK SIGNAL STRENGTH Connectors PC connection 9 way D Type female LINE connectors RJ11 POWER connection 2 1 mm DC socket Set up Set up data is stored in non volatile memory Setup can be done by using a telephone or PC Compatibility Compatible with most PABX s Required voltage 10 VDC to 16 VDC Current consumption 300 mA DOC NO SS 10C REV 02 Page 21 of 22 SS 10C USER MANUAL telecoms our solutions your success 10 CONTACT DETAILS
12. hone DB9 connector for programming 800MHz operation RUIM non RUIM operation SOFTWARE FEATURES Settable digit count Settable dial timeout Transmit amp receive levels adjustable Optional line voltage reversal Optional line current break Optional periodic module reboot 4 minute timer to reset CDMA module if not registered on the network MAINTENANCE FEATURES Routine periodic SMS reports Feed bridge voltages CDMA Module voltage Failed calls Total duration of calls SMS report on zero traffic no calls made for specified interval Request reports Request setting information Change set up information by SMS 2 authorized maintainers Programmable by serial port telephone or sms DOC NO SS 10C REV 02 Page 4 of 22 SS 10C USER MANUAL 3 DESCRIPTION 3 1 FRONT VIEW ON OFF button Power Indicator Holding in the On Off button while the Busy Indicator unit is powered up enables setup mode Network Indicator P M SS 10 ON OFF PWR BUSY NET RUIMCARD 4 RUIM card Press for Signal strength SMA antenna tray opening indicator connector RUIM tray 3 2 REAR VIEW Line Connector PC Connector DC Connector RJ 11 Connector DB9 Female Used for Connects DC voltage setup purposes between 12V and 18V to Only pins 2 amp 3 Use a standard PC the unit are used serial cable for Pin Description con
13. it Relative Level Value Description must be reset 07 12 dB 1 Soft new 6 dB 2 Factory Setting settings take 0 dB 3 Louder effect 46 dB 4 Loudest Receive Levels Set receive levels 1 4 2 normal Relative Level Value Description NB Unit 12 dB 1 Soft 08 6 dB 2 Factory Setting audio 0 dB 3 Louder settings take 6 dB 4 Loudest effect DOC NO SS 10C REV 02 Page 7 of 22 SS 10C USER MANUAL 5 2 REPORTING SETUP Parameter Description Notes No Call SMS Report 10 Sets the interval in minutes after which a report may be sent by SMS if no calls have taken place Set to 0 to disable no call reporting Routine Reports 11 Sets the interval in minutes between routine reports that will be sent by SMS to the pre programmed destination Set to 0 to disable routine reporting SMS Report Destination 12 Sets the destination number for SMS report Please include country code Eg 27828221381 SS 10 Identity 13 This command is only available from the serial port It is used to set a 16 character ID so that the SS 10 can identify itself in SMS messages that are sent International Digit Count 14 Sets the total number of digits needed before dialling if an international prefix 00 is detected 5 3 CALL DETAIL REPORTING Parameter Description Notes Call Record Prefix 20 Sets up a 2 digit number that will prefix call records that are output from the SS 10 The prefix is the line of th
14. l Fixed intervals between sending of reports SMS Control Info Authorised User Give authorisation to two users for controlling the access to the SS 10C unit via SMS by entering the user s numbers Country code to be included e g 27828221381 7 6 NETWORK Network Select the required Reset Interval if needed as well as the Connection Alert and Operation Type SS 10C USER MANUAL 55 10 Setup Call Parameters Call Back Call Barring SMS Options Network amp Security Reset ptions Reset Interval z Connection Alert Received No O Yes peration Type O RUIM Non RUIM Update 55 10 Fetch settings Load Settings Reset Interval Set the interval in hours and minutes between forced network log offs Connection Alert Received This feature is used in conjunction with Reversal on Answer The Neotel network does not currently send a connection alert as default Connection is assumed on call setup A true connection alert can be requested from the network if circumstances demand this for PABX configuration etc NB Please ensure that the Connection Alert has been enabled by the network before setting the Yes option This can be verified by the HFEEPO response in the command window when an outgoing call is connected Operation Type The SS 10C can be used with or without a RUIM card NB As a security feature the SS 10C will refuse to operate i
15. le Used to display the number list 61 An extra digit will precede the number 2 Indicates an allowed number 1 indicates a barred number Note Command will only work in serial setup mode Add Number 62 Add a 2 before the number to allow the number Add 1 before the number to bar the number Set Require Allowed 65 When this is set to 1 all numbers will be barred by default and allowed numbers have to be explicitly enabled 5 8 CALL BACK Parameter Description Notes 70 Erase Call Back Entries Erase all the call back entries by using 70 112233 Add Entry 71 Add a number to the call back list E g 71 0821111111 NB Number must begin with the 0 digit 72 Delete Entry Delete a number from the call back list E g 72 0821111111 Allow Any Number 73 Set to 1 allows any number to be called back Set to 0 enforces the listed numbers 5 9 MISCELLANEOUS Parameter Description Notes 80 Clear Totals Resets the report values 81 Set Report Timer Sets the time interval for the report timer DOC NO SS 10C REV 02 Page 11 of 22 SS 10C USER MANUAL 5 10 SETUP INFORMATION Parameter Description Notes 96 Reboot the CDMA Module Should be used after level changes 97 Sends a report back to originator 98 1 Sends SMS back to originator displaying first section of settings 98 2 Sends SMS back to originator displaying second section of settings 98 3 Sends SMS back
16. necting the unit to Inside positive voltage a PC Outside GROUND DOC NO SS 10C REV 02 Page 5 of 22 SS 10C USER MANUAL 4 SETUP Setup of the SS 10C can be done by using one of the following methods SMS Setup Method Sending SMS commands to the unit Telephone Setup Method Using a telephone connected to the SS 10C PC Serial Port Setup Method Sending commands to the unit by connecting it to a PC and use a Comms package like HyperTerminal or PC Serial Port Setup Method Connect the unit to a PC using the 959 106 Tool package Using SS 10 Toolkit Load the SS 10 Tool and refer to the notes Setup of the unit by using the SS 10 Tool Sending SMS commands The format of the commands using SMS is as follows Using a Telephone Setup Mode must be enabled Holding in the On Off button while the unit is powered up enables setup mode on the SS 10C en val where n is a command number and val is a value Dial the following lt nn gt lt ddd gt Where nn is the parameter number and ddd is the required setting Sending Commands using a Comms package From the serial port the format is enn gt lt ddd gt lt enter gt or lt nn gt lt ddd gt lt enter gt Where nn is the parameter number and ddd is the required setting DOC NO SS 10C REV 02 Page 6 of 22 SS 10C USER
17. to originator displaying third section of settings 98 4 Sends SMS back to originator displaying fourth section of settings 99 Displays all the settings DOC NO SS 10C REV 02 Page 12 of 22 SS 10C USER MANUAL 6 SERIAL PORT COMMANDS 6 1 SIMPLIFIED SERIAL PORT COMMANDS Simplified basic commands for entering via the serial port generally used for diagnostic or basic setup purposes Instruction Description Notes lt gt Gives a short report on state AT lt ddddddd gt lt enter gt Sends the data dddd to the cell module RESET lt enter gt Resets the SS 10 DIAG lt enter gt Toggles the diagnostic state of the SS 10 REP lt enter gt Sends a report SMS to the pre programmed destination lt nn gt lt ddd gt lt enter gt Sets parameter nn to value ddd SETID lt space gt lt sssss gt lt e nter gt Sets the ID of the SS 10 to sssss This is used to identify the particular SS 10C site name when automatic SMS messages are sent DOC NO SS 10C REV 02 Page 13 of 22 SS 10C USER MANUAL 7 SETUP THE UNIT BY USING SS 10 TOOL 7 1 MAIN WINDOW 5510 Tool Rev 1 45 File Font COMS 9600baud Setup Quick Check 55 10 CDMA Refresh SS 10 Tool Main Upload Firmware Window Get IMSI VER 655131 300000005 HUAWEI Technologies Load the SS 10 Tool EIOS 55 10 Rev 1 024 Beta

Download Pdf Manuals

image

Related Search

Related Contents

"取扱説明書"  BAC100-E and BAC100-T Service Manual for Splendid  TI-Nspire™/TI-Nspire™ CX Manual de Referência  BIOPLAST® XTREME Kit Herstellanleitung Instruction - tap  Stealth SCU-151 System User Manual    Intel GA-8I955X PRO User's Manual  Samsung ES73 Наръчник за потребителя  ProLite E511S-2/B2  MANUAL DE INSTRUÇÕES  