Home
        User Manual for SCILOGEX 7x7 Digital Hotplate-Stirrer
         Contents
1.   Display in case of remote control        Err  Display in case of error happening        Rated value Real  Display value in case of heating or  value stirring function switching ON        Table 3    Note    If both heating and stirring functions have been  started at the same time  heating function  always has higher priority  If in this case speed  is changed via the stirring knob  it displays  stirring speed and reverses to temperature in  the duration of 5 seconds     5     Trial run    Make sure the required operating voltage and power  supply voltage match    Ensure the socket must be properly grounded    Ensure the power is off    Plug in the power cable ensure the power is on and begin  initializing    Add the medium into the vessel with a stirring bar    Place vessel on the work plate    Set the rated stirring speed and begin    Observe the stirring bar and LCD display    Set the rated temperature and start heating    Observe the real temperature on LCD display    Stop the heating and stirring functions     If these operations above are normal  the device is ready  to operate  If these operations are not normal  the device  may be damaged during transportation  please contact  manufacturer for technical support     Digital 7    Square Hotplate Magnetic Stirrer       6  Initialization    6 1 Initializing sequence    e Turn on instrument by the power switch    e The Heat and Stir LEDs and the LCD display  flash about 3 times    e LCD displays the work plate  safe tempe
2.   Protective ground contact     e Make sure that socket must be grounded     protective ground contact  before use     When working wear personal safety guards to avoid the  risk from      Splashing and evaporation of liquids     Release of toxic or combustible gases  Set up the instrument in a spacious area on a stable   clean  non slip  dry and fireproof surface  Do not operate  the instrument in explosive atmospheres  with hazardous  substances or under water     Gradually increase the speed  reduce the speed if       Stirring bar breaks away due to high speed     The instrument is not running smoothly  or container   moves on the base plate   Temperature must always be set to at least 50  C lower  than the fire point of the media used   Be aware of hazards due to      Flammable materials or media with a low boiling   temperature     Overfilling of media     Unsafe container  Process pathogenic materials only in closed vessels   Check the instrument and accessories prior to each  use  Do not use damaged components  Safe operation  is only guaranteed with the accessories described  in the Accessories chapter  Accessories must be  securely attached to the device and can not come off by  themselves  Always disconnect the plug before fitting  accessories   Ensure that the external temperature sensor is inserted in  the media to a depth of at least 20 mm   When using metal vessels  do not place the temperature  sensors on the bottom of the vessel  This can cause  excessively hi
3.  Table 5    Digital 7    Square Hotplate Magnetic Stirrer       14 Ordering information       Cat No     Descriptions       813223009999    813223019999    813223029999    813223039999    813213009999    813213019999       MS7 H550 Pro Digital 7 Square  Hotplate Magnetic Stirrer  glass ceramics  hotplate  USA plug  110V 50Hz 60Hz    MS7 H550 Pro Digital 7 Square  Hotplate Magnetic Stirrer  glass ceramics  hotplate  Cn plug  220V 50Hz 60Hz    MS7 H550 Pro Digital 7 Square  Hotplate Magnetic Stirrer  glass ceramics  hotplate  Euro plug  220V 50Hz 60Hz    MS7 H550 Pro Digital 7 Square  Hotplate Magnetic Stirrer  glass  ceramics hotplate  UK plug  UK plug   220V 50Hz 60Hz    MS7 Pro Digital 7 Square Plate  Magnetic Stirrer  glass ceramics plate   USA plug  110V 50Hz 60Hz    MS7 Pro Digital 7 Square Plate  Magnetic Stirrer  glass ceramics plate  Cn  plug  220V 50Hz 60Hz       MS7 Pro Digital 7 Square Plate                      813213029999   Magnetic Stirrer  glass ceramics plate   Euro plug  220V 50Hz 60Hz  MS7 Pro Digital 7 Square Plate  813213039999   Magnetic Stirrer  glass ceramics plate  UK  plug  220V 50Hz 60Hz  Accessories  PT1000 Temperature sensor for digital  18200016 hotplate model  length 230mm  PT1000 Temperature sensor for digital  eens hotplate model  length 100mm  18900017 Support clamp of PT1000  MS135 2 Red quarter pie  11 holes  4 ml  18900002 reaction vessel  015 2mm  20mm depth  MS135 3 Purple quarter pie  4 holes  20  18900003 ml reaction vessel   28mm  24mm
4.  depth  18900004 MS135 4 Blue quarter pie  4 holes 30 ml       reaction vessel  028mm  30mm depth       Digital 7    Square Hotplate Magnetic Stirrer       18900005    18900048    MS135 5 Black quarter pie  4 holes 40 ml  reaction vessel  028mm  43mm depth    MS135 6 Green quarter pie  6 holes  8ml  reaction vessel  017 75mm  26mm depth       18900049    MS135 7 Golden quarter pie  4  holesQ16ml reaction vessel  021 6mm   31 7mm depth       18100319       9 Pin interface line  suitable for StirPC V2  software     Table 6    Note The software StirPC V2 can be freely downloaded  from our website www scilogex com        15 Main spare parts    15 1 Spare parts diagram                     SI           A                   K             A A       Digital 7    Square Hotplate Magnetic Stirrer       15 2 List of spare parts       Item Spare parts Item Spare parts  1   Work plate 9  Main circuit board  Hole for external  2   temperature 10   Driver circuit board  sensor  3   Mains switch 11   Heating parts    Direct current  4  H 12  o brushless motor  Int It  5  Control panel ils Penns  sensor  6 ELL aq 14  Permanent magnet  sensors socket  7  Remote control socket   15   Protective plate  8  Main socket 16   Rubber foot       17    SCILOGEX  LLC    500 Four Rod Road  Suite 122  Berlin  CT 06037  USA  Tel  1   860  828 5614  Fax  1   860  828 5389  E mail  info scilogex com  Website  Http   www scilogex com    
5. Digital 7    Square  Hotplate  Magnetic Stirrer       User Manual    MS7 Pro Digital 7 Square Plate Magnetic Stirrer    MS7 H550 Pro Digital 7 Square Hotplate Magnetic Stirrer    Please read the User Manual carefully before use  and follow  al operating and safety instructions        www scilogex com       SCILOGEX    12300090    Contents    Preface  Service  Warranty  1 Safety Instructions  2 Proper use  3 Inspection  3 1 Receiving Inspection  3 2 Listing of Items  4 Control and Display  4 1 Control Elements  4 2 Display  5 Trial run  6 Initialization  6 1 Initializing Sequence  6 2 Default Settings  7 Function  Heating  7 1 Working with External Temperature Sensor  7 2 Residual Heat Warning Hot   7 3 Setting the Safety Temperature  8 Function  Stirring  9 Remote Control  10 Faults  11 Maintenance and Cleaning    OIO   o GO MO OMO I LILI UI GI I BPWNN LN    12 Associated Standards and Regulations  13  Technical Data  14 Ordering Information  15 Main Spare Parts  15 1 Spare Parts Diagram  15 2 List of Spare Parts    13  13  15  16  16  17    Digital 7    Square Hotplate Magnetic Stirrer       Preface    Welcome to the Digital 7 Square  Hotplate  Magnetic  Stirrer User Manual   Users should read this Manual  carefully  follow the instructions and procedures  and be  aware of all the cautions when using this instrument     Service    When help needed  you can always contact the Service  Department of manufacturer supplier for technical support  in the following ways      SCILOG
6. EX  LLC   500 Four Rod Road   Suite 122   Berlin  CT 06037   USA   Tel  1   860  828 5614   Fax  1   860  828 5389   E mail  info scilogex com  Website  Http   www scilogex com    Please provide the customer care representative with the  following information    e Serial number on the rear panel   e Description of problem  i e  hardware or software    e Methods and procedures adopted to resolve the problems  e Your contact information    Warranty    You have purchased a Scilogex instrument  This instrument  is warranted to be free from defects in materials and  workmanship under normal use and service  for a period  of 24 months from the date of invoice  The warranty is  extended only to the original purchaser  It shall not apply to  any product or parts which have been damaged on account  of improper installation  improper connections  misuse   accident or abnormal conditions of operation    For claims under the warranty please contact your local  supplier  You may also send the instrument directly to  manufacturer  enclosing the invoice copy and by giving  reasons for the claim     Digital 7    Square Hotplate Magnetic Stirrer       1 Safety Instructions    Warning   e Read the operating instructions carefully  AN before use   e Ensure that only trained staff works with the  instrument   Risk of burn     e Caution when touch the housing parts and       the hotplate which can reach temperature of  A 550  C   MaA    Pay attention to the residual heat after    switching off   
7. automatically switch off  If users want to turn off  the LCD immediately  just pull out the plug directly  When  the plug is pulled out  the residual heat warning function can  not be run     Digital 7    Square Hotplate Magnetic Stirrer          Figure 6    7 3 Setting the safety temperature    The safety temperature can be set as follows     Adjust the temperature setting key to set the safety    temperature     8 Function  Stirring    The function stirring is switched on or off via rotating  stirring knob  The speed is set on the knob  100 to 1500 rpm  in steps of 10 rpm      When both of function heating and stirring are switched on  and those above operations are done  the LCD will shift to  the speed value and come back to the temperature value in  about 5 seconds     9  Remote control       Connection PT1000 RS232C Socket    Figure 7    Digital 7    Square Hotplate Magnetic Stirrer       The unit can be controlled from an external PC  using the   dedicated software  via the RS232 C serial interface fitted to   the unit  Data communication from laboratory instrument to  computer is only possible on demand of the computer    e The functions of the interface lines between laboratory  instrument and automation system are selected from  the specified signals of the EIA standard RS232C   corresponding with DIN66020 Part 1  The allotment of  the bushing can be taken from Figure 7    e Transmission method  Asynchronous signal transmission  in start stop operation    e Mode oft
8. ent is turned on for the setting zone temperature   setting when the last shutdown temperature  the common    Digital 7    Square Hotplate Magnetic Stirrer       case  set the heating temperature display the actual  temperature may have the following differences       Hotplate center and outer edge      The sample container and the container   In order to ensure the accuracy of the temperature inside  the container  please use the external temperature sensor  PT1000     7 1 Working with external temperature    sensor    The external temperature sensor PT1000 is the    Manufacture s standard accessory  If the sensor is not  plugged in  Probe will flash  If plugged in  Probe  will be shown on the digital display to indicate the sensor is  operating  The setting value of external temperature sensors  and actual temperature are displayed  Safe circuit controls  hotplate temperature    Comparing with the temperature control of the hotplate   the external temperature sensor can control the medium s  temperature more precisely     Warning   Do not insert or remove sensor while heating     7 2 Residual heat warning  Hot     In order to prevent the risk of burns from a hotplate  digital  hotplate model has a residual heat warning function   When the heating function is switched off and the hotplate  temperature is still above 50  C  Hot will flash to warn  that there is a hazard of burns from the hotplate  Figure  6   When the hotplate temperature drops to below 50  C  the  unit will 
9. es  89 336 EWG  Instrument guidelines  73 023 EWG      The above standards will be available from July 2011     13 Technical data    Voltage  VAC     Frequency  Hz   Power  W     Stirring point position quantity  Max  stirring quantity  H20   L   Max  magnetic bar  mm    Motor type    Max  power input of motor  W        Max  power output of motor  W   Speed range rpm    Rotary speed display   Speed display accuracy  rpm   Hotplate material    Dimensions of workplate  mm        100 120 200 240  50 60    ae model     N       0   80   Brushless motor  18   10   100 1500   LCD   1   Glass ceramic    184 184    Digital 7    Square Hotplate Magnetic Stirrer       Dimensions of heating  mm  176 176 Weight  kg    5 3  Heating power  W  1000 hotplate model  Permitted ambient temperature  C     5 40  RT 550 Permitted relative humidity   80     Temperature range  C   i    howlate model  Protection class acc  to DIN 60529   IP21    Temperature display  C    Temperature display accuracy   C     Control accuracy of heating  temperature  C     The safety temperature range  of the hotplate   C     Temperature sensor in medium    Control accuracy of heating  temperature with temperature  sensor  C     Residual heat warning    Dimensions  mm        LCD hotplate model   0  I hotplate model     1 100 C below    1  100  C above    hotplate model     100 580   hotplate model     PT1000   hotplate model     0 2 hotplate model     50 C  hotplate model   215 360 112    RS232 interface       Yes      
10. gh temperatures to be measured especially  in media with poor conductivity     Digital 7    Square Hotplate Magnetic Stirrer       The tip of the measuring sensor must be at least 5 mm  from vessel bottom  a distance of 10 mm is ideal    The instrument can only be disconnected from the main  power supply by pulling out the main or the connector  plug    The voltage stated on the label must correspond to the  main power supply    Ensure that the main power supply cable does not touch  the hotplate  Do not cover the device    The instrument may only be opened by experts    Keep away from high magnetic field     2 Proper use    The instrument is designed for mixing and or heating liquids   in schools  laboratories or factories    e Observe the minimum distances between the devices   between the device and the wall and above the assembly   min  100 mm          gt 100mm             Figure 1  This device is not suitable for using in residential areas or  other constraints mentioned in Chapter 1     Digital 7    Square Hotplate Magnetic Stirrer       3  Inspection    3 1 Receiving Inspection    Unpack the equipment carefully and check for any damages  which may have arisen during transport  Please contact  manufacturer supplier for technical support    Note    If there is any apparent damage to the system    please do not plug it into the power line     3 2 Listing of Items          Items Qty  Main unit 1  Power cable 1  User Manual 1       Table 1    4 Control and Display    4 1 Co
11. ntrol elements    LED Heat   Hotplate model     LCD        Temperature Control Knob   Hotplate model     Speed Control Knob Safe Temperature Control Knob    LED Stir    Figure 2          DAN   ILII      Power Switch    Figure 3    Digital 7    Square Hotplate Magnetic Stirrer          Items    Descriptions       Speed control Knob    Set the rated rotary speed  The  stirring function is switched ON  or OFF by pushing the knob        Temperature control    Set the rated temperature  The  heating function is switched ON             sep LE or OFF by pushing the knob   LCD LCD displays the real working  state and all settings   LED Heat Hotplate  When the heating function is  switched  LED Stir When the stirring function is    switched ON  the LED Stir is lit        Safe temperature  control Knob    Set safety temperature  stop  heating when exceed secure  temperature        Power Switch       Switch ON or OFF the  instrument        Table 2    4 2 Display    Real value Temperature Stir    Hi   OL     LI LI  6    Remote External Hotplate  control probe warning       Figure 4       Character    EMI  i I    Descriptions    Display temperature when the heating  function is switched ON        Mot    Display stirring state when the stirring  function is switched ON        Display hot warning if the hotplate  temperature is above 50C after  switching OFF the heating function        Probe    Display when using external probe           Digital 7    Square Hotplate Magnetic Stirrer        
12. ransmission Fully Duplex  1start bit  7 character  bits  1stop bit    e Transmission speed  9600 bit s    e Start remote control knob LED display Remote    A    Note   Forbid to insert or remove the RS232C  communication line when switch on     10 Faults    e Instruments can not be power ON    Check whether the power cable is plugged in      Check whether the fuse is broken or loose  e Fault in power on self test     Switch OFF the unit  then switch ON and reset the  instruments to factory default setting    e Temperature can switched on not reach set point     Check whether the safety temperature value is set too  low    e Stir speed can not reach set point     Check whether the stirring bar breakaway monitoring  is ON      Excessive medium viscosity may cause abnormal  speed reduction of the motor    e Heating or stirring function do not start when knob is  pressed      Check whether the unit is in the mode setting program      Exit from the mode setting and restart the heating   stirring functions    e Unit do not power down when switched off      Check if the residual heat warning function is still ON  and hotplate temperature is above 50  C  the LCD still  works and Hot flashes     Lt these faults are not resolved please set the instruments  to factory default setting or take the unit to technical service  center     Digital 7    Square Hotplate Magnetic Stirrer       11 Maintenance and Cleaning    Proper maintenance can keep instruments working  properly and lengthen it
13. rature limit in   SAFE xxx C   e LCD displays residual heat warning rES On OFF   e LCD displays stirring bar breakaway monitoring br  On OFF     e LCD displays the Probe  connecting with external temperature sensors     characters in case of    6 2 Default settings    The following table is supplied with default settings        Items Default settings    Setting temperature   C   25       Setting rotary speed  rpm  100       Table 4    7 Function  Heating    The device is controlled by digital temperature control   technology  which has two separate safe circuits  The   hotplate is kept at a constant temperature by a digital control   circuit  The hotplate temperature can also be monitored   from a separate  adjustable safe circuit  The two temperature   sensors  PT1000  internal for temperature control are built   into the hotplate  The single external PT1000 can monitor   the temperature of sample    If external temperature sensors needed  it must be plugged in   before the device is switched ON    e Ensure the external temperature sensor connect firmly  before heating    e Set the temperature via turning the temperature control  knob slowly to the ideal value    e When the heating function is switched on  the LED   Heat will light up and the LCD will display the real   temperature    e The rated temperature will be displayed on the right hand  side of the LCD as well as Temp and C characters    e The heating function is switched on or off by pushing  heating knob    Instrum
14. s lifetime    Do not spray cleanser into the instrument when cleaning   Unplug the power line when cleaning    Only use recommended cleansers                 Dyes Isopropyl alcohol  C    str  ction materiais Water containing tenside   Isopropyl  alcohol     oaziso Water containing tenside   Isopropyl  alcohol  Foodstuffs Water containing tenside  Fuels Water containing tenside       Wear the proper protective gloves during cleaning of the  instrument    Before using other method for cleaning or  decontamination  the user must ascertain with the  manufacturer that this method will not harm the  instrument    Send in the case of service the instrument back in the    12    packaging carton  Storage packing is not sufficient for the  back dispatch  Use additionally a suitable transportation  packing    The enamel makes the hotplate easier to care for  and more resistant to acids and bases  Because of it   however  the hotplate is also more susceptible to extreme  fluctuations in temperature and the force of impact  This  can result in cracks forming or the coating flaking off     Warning   Cut off power when maintenance and cleaning     Digital 7    Square Hotplate Magnetic Stirrer       12  Associated standards and  regulations    Construction in accordance with the following safety  standards     EN 61010 1   UL3101 1   CAN CSA C22 2 1010 1   EN 61010 2 10    Construction in accordance with the following EMC  standards     EN 61326 1    Associated EU guidelines     EMC guidelin
    
Download Pdf Manuals
 
 
    