GSM House Alarm System User Manual Ver 1.20 Date Issued: 2010

image

Contents

1. 7 2 2 Disarm xxxx Stands for the password 1 4 digits A When the Password is 1111 System deactivated 7 2 3 Switch On the independent output relay 000 stands for the password 1 4 digits MCC Output Relay Closed When the Password is 1111 7 2 4 Switch OFF the independent output relay xxxx stands for the password 1 4 digits 1111DD When the Password is 1111 Output Relay Opened Page 20 of 31 Ver 1 2 A Top Safety and Protection Solution In The Worldwide 7 2 5 Inquiry System Status Notice The Output relay status in the Return SMS is the independent output relay status It is not the alarm link Output Relay Status 8 Installation Before installing the control unit and sensors and sirens please help to test the system firstly including wireless sensor power supply gsm signal etc Please ensure the wireless sensors and electricity appliances from the mainframe more than 3 5m 8 1 Insert SIM into Control Unit and install the GSM ANT In the backside of the control unit please install the GSM SIM card GSM SE The GSM ANT must be Vertical installation to ensure it in good working condition 8 2 Install the Magnetic door window sensors Page 21 of 31 Ver 1 2 A Top Safety and Protection Solution In The Worldwide Magnetic door window sensors signal the Control Unit when the two parts separate by more than between 1 5 to 3 0cm Low Voltage Indicat
2. to the first SMS Alert numbers after the AC power failure 30minutes if the power is recovery then will send SMS AC Power is OK Default is disabled 6 There s no delay for Stay Mode 6 2 2 3 Advanced Setting To setup the starting time to arm and the Ending time to disarm To setup the starting and ending time to work To setup the remote control operation report function To setup the GSM Jammer Alert function Modify the system password Restore the system settings to factory defaults All of the remote controls and wireless sensors should be re assigned again Notice 1 The watchdog is special for elder or child or on duty personnel in the period Starting time point to Ending time point if this sensor hasn t been triggered the system will alarm This is very useful to monitor the elder or child goes out the bedroom or enters the kitchen to eat something Or monitor the on duty personnel in the polling period have gone to on site inspection 2 If enable the RCO alert function then when use any remote control which has been registered to the system to arm or disarm or stay operation the system will send SMS to the first SMS number 3 If enable the GSM Jammer Alert function when the GSM Signal is O for more than Page 17 of 31 Ver 1 2 A Top Safety and Protection Solution In The Worldwide 90s the system will drive the siren for 6Oseconds and the link output relay will close 4 minutes 6 3 Modify
3. GSM House Alarm System o User Manual Ver 1 20 Date Issued 2010 05 14 A Top Safety and Protection Solution In The Worldwide 10 Table of Contents Brief introduction 2 Safety Directions 2 Standard Packing list 3 Physical Layout 3 Features 92 0 02 0 9 Settings 7 Operating Instructions 17 Installation conn nnn nnn nnn nena nena anna anne enna senna 20 Add wireless sensors mn 24 Technical specifications 26 Page 2 of 31 Ver 1 2 11 EZ I3 14 A Top Safety and Protection Solution In The Worldwide Important information 27 Maintenance 27 Quality Warranty mo 28 Trouble Shooting Guide 28 1 Brief introduction The GSM Alarm System is a new security protection solution special for home house and office and other applications It based on Wireless GSM Communication network integrated Lcd Menu display and Computer technology When any sensor activated it will Call amp Send SMS to owner s telephone immediately The GSM Alarm System with user friendly design idea all operations and settings are visual and intuitive What you need is a SIMCard which supports Call ID function
4. 2 Safety Directions Safe Startup Do not use GSM Alarm System when using GSM equipment is prohibited or might bring disturbance or danger Page 3 of 31 Ver 1 2 A Top Safety and Protection Solution In The Worldwide Interference All wireless equipment might interfere network signals of GSM Alarm System and influences its performance Avoid Use at Gas Station Do not use GSM Alarm System at a gas station Power off GSM Alarm System it near fuels or chemicals Power it off near Blasting Places Please follow relevant restrictive regulations Avoid using the device in blasting places Reasonable Use Please install the product at suitable places as described in the product documentation Avoid signal screening by covering the mainframe Use Qualified Maintenance Service Maintenance can be carried out only by qualified maintainer Waterproofness The product is not waterproof Please install it at dry places and keep it dry 3 Standard Packing List Control Unit X1 Wireless Magnetic Door Sensor X1 Wireless Remote Controls X 2 Page 4 of 31 Ver 1 2 A Top Safety and Protection Solution In The Worldwide Wireless PIR Motion Sensor X1 Wired Mini Siren 110dB X1 Regulated 12VDC Power Supply X1 User Manual X1 GSM Antenna X1 Optional Accessories Wireless Sensors only PIR Motion Sensor Glass Break Sensor Magnetic Window Sensor Magnetic Steel Scrolling Door Sensor Temperature Sensor Photoelectric Beams e
5. Range 0 240Hours deflaut is O will not report Enable or Disable the alert function while the AC power is failure more than 30 minutes Setup the delay time after armed the system by remote control or keyboard Optional 0S 20S 305 60S 90S Default is 30S Setup the delay time after any sensor triggered Optional OS 20S 30S 60S 90S Default is 20S Notice 1 The SMS Alert number is for receiving the alarm SMS Message The Auto Dial Telephone number is for receiving the calling Please help to try adding country code or removing country code when you can not receive the call or SMS Because of Page 15 of 31 Ver 1 2 A Top Safety and Protection Solution In The Worldwide different GSM Operator with different communication protocols Our system is with the international communications protocols 2 The Auto dial Tel Number can dial to the unit 6 tones later can wiretap the system site Before 6 tones if somebody answers the calling then can create two way voice communication The other telephone number can call in the unit if nobody answer the calling then can not wiretap the system site if somebody answers the calling then can create two way voice communication For example In China the country code is 0086 please note do not write 86 The user cell phone number is 13570810254 and has been assigned as a SMS Alert number the simcard number in the panel is 13512345678 Problem 1 Alarm
6. The unit works with wireless detectors only It can switch on or off one appliance by SMS command Please see below 7______ Wireless _________ C Smoke Detector C Fire Detector Antenna SMS Control Light Page 6 of 31 Ver 1 2 A Top Safety and Protection Solution In The Worldwide 5 Features 5 1 The advantages of the GSM Alarm System 7 8 Two way Voice communication or wiretap are available LCD displays the entire setup menu Armed Partial Armed At House or Stay Disarmed SOS are available Armed delay alarm delay siren work or not more other functions are Programmable by user Watchdog 24Hours Zone SOS zone are available Using ICON to display armed Partial Armed Disarmed Power status Siren status and GSM Signal status Auto detect and report GSM Signal Jammer alarm SMS Switch is available User friendly Icons for LED indicators LCD and functional Buttons 5 2 Functions amp Features of the GSM Alarm System 1 2 GSM Frequency Dual Band 900 1800MHz Quad Band is optional 850 900 1800 1900Mhz Supports armed Partial armed At House or Stay or disarmed SOS by remote control or mainframe keyboard Supports armed disarmed inquiry mainframe status switch on or off relay output by SMS Commands Automatically send SMS Alert and dial to the pre set cell phone when any sensor had been triggered Page 7 of 31 Ver 1 2 A Top Safety and Protection Solution In The World
7. but the user hasn t received the SMS Alert Solution Please plus the country code while you setup the 13570810254 as SMS Alert number means setup 008613570810254 to instead of the 13570810254 Problem 2 The user number can receive the SMS Alert message from alarm panel but the alarm panel can not receive the commands from the user number Solution Please add country code to the simcard number in the alarm panel Means send sms commands to 008613512345678 to instead of 13512345678 Solution 3 When you use cell phone dial another one what number it will be displayed then you can set the displayed number as dial numbers when you use cell phone send SMS to another cell phone what number it will be displayed then you can set the displayed number as SMS Alert number just use the 00 to replace the aq 3 If Switch off the siren then all alarm raised will not drive the siren if switch on the siren then when the system alarm will drive the siren for 1 minute except the SOS help caused Default is Switch on 4 Ifsetup the Report Time Gap the system will periodically send GSM Alarm System in good working condition to the first SMS Alert number This is very useful for long Page 16 of 31 Ver 1 2 A Top Safety and Protection Solution In The Worldwide time use the system Default is 0 Means will not report the system condition 5 If enable the power failure alert function the system will send SMS AC Power Failed 30Min
8. from the preset alarm number after 5 tones if hasn t been answered will hang up If you want to test the two way voice communication please make sure the other phone is far from the unit at least 500meters Otherwise the near cross will make lots of noise interference 6 1 Key Function Descriptions Page 9 of 31 Ver 1 2 A Top Safety and Protection Solution In The Worldwide 6 17 19 Led indicator Description The unit uses the icons to descript the function it will be more user friendly to user e Stay Mode indicator on is in stay mode pa Arm Mode indicator on is in arm mode off is in disarm mode Alarm Indicator on is alarming off is normally GSM Module indicator registering will quickly flick registered successful will slowly flick Alarm link output indicator when alarm will turn on and last 4minutes means the alarm link output relay closing Independent output relay indicator when the independent output relay closed 1t will be on when the independent output relay opened will be off 6 1 2 LCD ICONS Description The unit uses the icons to descript the present status 1t will be more user friendly Enabled the Timer to arm and disarm function otherwise will not display it Page 10 of 31 Ver 1 2 A Top Safety and Protection Solution In The Worldwide Timer to Arm has setup a time point to enter armed mode directly Timer to disarm Has setup a time point to ente
9. the panel with 5 problem 1 PIR Motion sensor 1 installation incorrect 2 Used 24H zones or 2 SOS Zones or Watchdog zone GSM Operator communication protocol Haven t setup SMS Alert Auto dial Numbers Caps Lock letters in the SMS Commands Please contact your distributors or manufacturer to replace it Please see the PIR Motion sensor installation user manual carefully Please check if any sensor assigned to these special zones and made incorrect activated Please setup the SMS Alert Numbers Please help to see Page 15 the sample of setup the telephone numbers Please check the commands with CAPS LOCK and correct format Also please help to change another GSM Operator SIMCard to test it Page 31 of 31 Ver 1 2
10. Ver 1 2 2 3 4 9 6 8 A Top Safety and Protection Solution In The Worldwide Also you can insert the SIMCard after you setup All the wireless sensors in the standard package we have assigned to the mainframe already Needn t to learn it again After you power on the mainframe the mainframe will auto detect and display the process If it with SIMCard it will register the GSM Network and display the GSM Signal ICON in the left corner of the LCD All of the setup can be done by the LCD except modify the Zone name if you need to modify the zone name please see the command list in the related chapter Only disarm by keyboard and modify settings requires password the other operation needn t password The default password is 1234 Enter password then press Enter button to enter the system In standby mode press 3 6 following UP button The system will recovery to factory default settings the password will be 1234 But the registered wireless sensors will remain Two way communication In standby mode dial the telephone number following the Enter Button the system will dial out While incoming call press the Enter Button to answer the incoming Please note if the income calling is from the preset number then before 5 tones if answered it will create two way voice communications After 5 tones will be entering into wiretap status The user can listen in the alarm around sounds If the income calling is not
11. ain sensor detection area illustration below p e 8 4 Install other sensors For smoke you can use wireless smoke sensor for gas leakage detection you can install gas leakage sensor below I f olo AW 8 5 Install the Control Unit In order to avoid destruction of the Control Unit by intruders please install it in a concealed location convenient to the operator If applicable ensure that an uninterruptible AC power outlet is available near the Control Unit First connect accessories to the Control Unit then the AC adapter 8 6 Install Siren Connect the Siren to the Control Unit and fix them in appropriate locations Page 24 of 31 Ver 1 2 A Top Safety and Protection Solution In The Worldwide Strobe Siren Siren Light Siren 8 7 Install output relays The unit with two output relays one is for SMS Control another is for alarm output Please select the one you required The SMS control output relay is useful while you re not at house then you can send SMS to switch on the light and then switch it off if you need This action will stop the intruder to break your house because of they see the light is on The Alarm Link Output Relay is for switching on the light once the alarm system triggered for 4 minutes For example when the intruder breaks the door or windows then the siren sounds and the light turn on the criminal will escape at once The connections please see the photo also you can use any other el
12. e Remote Control the system will show a code then press Enter Key on the Keyboard The system will ask you repeat the operation so please trigger Remote Control again when you see the Code then press the Enter Button on the Keyboard the system will display Saved OK It means the Remote Control added to the system Repeat this operation to add other remote controls Notice 1 VVVV means this serial position saved one remote control already you can learn a new remote control to replace it 9 5 Delete all wireless sensors and remote controls Go back to the menu then select the Remove All select it then the system will alert Are You Sure gt Press Enter to remove all the RF Parts of the system 10 Technical specifications of Control Unit Rated Voltage 9 12VDC 1 5A Standby current 30 40mA Siren Output Voltage 12VDC Working temperature 1000 60 Storage temperature 20011 60 Relative humidity 10 90 No condensation Work frequency 900 1800 MHz or 850 900 1800 1 900MHz Communication protocol GSM PHASE 2 2 include data service Wireless sensor receiving frequency 433 92 MHz Page 28 of 31 Ver 1 2 A Top Safety and Protection Solution In The Worldwide Wireless sensor permission quantity 16Pcs Remote Control permission quantity 5Pcs Effective distance wireless of remote control 100 m Battery Built in lithium ion battery 1000mMAN 3 7V Standby time Approx 24hours de
13. e wireless sensor can transmit wireless signal 6 2 2 Setup To add or remove wireless sensors or remote controls and edit their attributes To setup basic parameters of the system To setup the advanced parameters of the system 6 2 2 1 Add Del RF Parts Page 12 of 31 Ver 1 2 A Top Safety and Protection Solution In The Worldwide To setup the zone s attribute and add new wireless sensors to specificities zone To add new remote controls To remove all registered wireless sensors and remote controls Notice 1 Zones Attribute definition and not alarm in disarmed mode In Stay mode the sensors with Stay type triggered will alarm the sensors with Normal type triggered will not alarm Watchdog In the starting time point and ending time point the sensors with this type triggered will not alarm if the sensor hasn t been triggered will make alarm SOS Help In any mode the sensors with this type triggered will alarm but not drive the siren Alarm Action when Alarm occurrence the system will Automatically dial the Pre set Auto Dial Tel Numbers for 3 times one by one and Send SMS to the Pre set SMS Alert Numbers in the meantime will drive the siren for 60seconds and close the link Output relay for 4 minutes 2 After you enter the menu the attribute of the zone will be displayed in the LCD if this zone has been assigned wireless sensor will display V If hasn t been assigned wirel
14. ectric equipment to instead of the lights Page 25 of 31 Ver 1 2 A Top Safety and Protection Solution In The Worldwide Please remove these plastic before you connecting the relay outputs QA Siren AC Power we de tsi AR DAS we r Alarm Link Light SMS Control Light 9 Add Wireless Sensors to the Control Unit Notice Some wireless sensors must be coded by manual as below 9 1 step some wireless sensors needn t coded by manual because of we will use the learning code sensor The learning code wireless sensor you can omit the 9 1 step can be learned to the system directly like the PIR 100B and DM 100A The Wireless sensors in the package box are pre coded prior to shipping The Max Quantity of RF sensors is 16 if you need add more then you can set the wireless sensor with the same jumper Add additional wireless sensors to the control units please help to see below 9 1 Prepare the RF Sensors of PT2262 IC Code 1 Prepare the RF sensors Open the back cover of the Wireless sensor Page 26 of 31 Ver 1 2 A Top Safety and Protection Solution In The Worldwide 2 Locate the IC boards black jumpers labeled AO A7 and DO D3 3 Configured the AO A7 and DO D3 different from each wireless sensors Includes wireless door sensor wireless smoke sensor wireless gas leakage sensor wireless pir motion sensor and so on If configured the AO A and DO D3 are the same the system will treat them as the same one sen
15. ess sensor means this zone is empty you can assign new wireless sensor to this zone Press Up or down button on the keyboard to check the other Zones Press Enter to edit it After you pressed the Enter button you can select the zone attribute and then press Enter you can see Turn on the device or Please trigger the new wireless sensor Then following the instruction to add the new wireless sensor to the unit For Remote control it will display VVVV if the unit has been assigned remote control Both of them you can press Enter to re assign new wireless sensor or remote control to replace the existence one 3 Inthe Edit RF Parts you can edit the attribute of the sensor as Normal or Stay Type If the system is under Stay Mode Also said At House or Partial Armed the sensor Page 13 of 31 Ver 1 2 A Top Safety and Protection Solution In The Worldwide set as Normal triggered will not alarm the sensor set as Stay triggered will Alarm If the system is under Armed Mode then all RF sensors triggered will alarm This is very important to remember the sensor types of the system This function is very useful when you at house and need some sensors in working status E g the sensor installed outer and gas and smoke detectors etc and some sensors indoor not in working status e g the sensors installed in the living room bed room etc 4 The unit can accept total 16 wireless sensors to 16 wireless zones each zone can be assig
16. is warranty does not extend to any defect malfunction or failure caused by abuse or misuse by the Operating Instructions In no event shall the manufacturer be liable for any alarm system altered by purchasers 14 Trouble Shooting Guide PROBLEM CAUSE POSSIBLE SOLUTION GSM Module Backup battery with Please contact the AC Power failed Module connection l l loose in mobile phone repairmen store and transportation then ask the engineer to check the GSM Signal is 100 GSM Module socket and the GSM weak Module connection Please change another position to install the alarm panel Automatically 1 Backup battery with 1 When the backup battery voltage is Restart low voltage lower than 3 7V the panel will alert by buzzer sounds Please help to contact the AC Power Wireless 1 Wireless sensor with Please replace the battery of the Sensor low voltage wireless sensor usually once year ee 2 Wireless sensor used Please correct the resistor value to PT2262 IC and 3 3M Ohm of the PT2262 Wireless incorrect Value sensor 3 Haven t pull out Please pull out the wireless sensor wireless antenna antenna 4 Electromagnetic Please install the wireless sensors or interference alarm panel away the electric 5 The wireless receiver equipments Page 30 of 31 Ver 1 2 False Alarm Alarm without SMS Alarm without Dial No action after send SMS command A Top Safety and Protection Solution In The Worldwide in
17. ned one wireless sensor and renamed it by SMS Command And 5 remote controls 5 Zone Serial Number Default Zone Name and Zone Attributes Table 06 Intrusion from Front Balcony Normal 08 Intrusion from 1F Window Normal S 09 Intrusion from 2F Window Normal S Medical Button Alarm 24 Hour zones This attribute can not be SIE LS ce Ean modified In arm or disarm or stay Smoke Fire Alarm mode once the sensor in these zones triggered will alarm immediately 15 Watchdog alarm Watchdog Zone the attribute can not be modified In arm or disarm or stay mode once the sensor in this zone triggered in the preset time will not alarm if the sensor hasn t been triggered in the preset time will alarm SOS Help SOS zone The attribute can not be Page 14 of 31 Ver 1 2 A Top Safety and Protection Solution In The Worldwide modified In arm or disarm or stay mode once the sensor in these zones triggered will alarm immediately But not drive the siren Notice The SOS button on the Keyboard and remote control is the same attribute with the SOS zone 6 2 2 2 Basic Setting To setup the SMS Alert Number must be cell phone numbers total 3 To setup the Auto dial telephone number total is 5 To setup the time and date information The Format is Month Date Year Press Up Down to setup each item press move to next item Switch on or off the siren when Alarm occurrence Setup the Report time gap
18. or 8 Double Faced Tape Work Indicator In some circumstances an Infrared beam fence is more appropriate than magnetic sensors i e veranda picture window balcony boundary wall e t c TH Wireless glass break sensor can also be used see below A For a Scrolling Steel Door a special Wireless Scroll Steel Door magnetic sensor must be used due to interference of the wireless signal caused by the steel door Page 22 of 31 Ver 1 2 A Top Safety and Protection Solution In The Worldwide Installation attach the larger half to the floor and attach rivet or glue the smaller half to the scroll steel door An alarm is triggered when the halves are separated by more than three to 5 00 cm Vey X Rivet it on the floor J Rivet or stick 3 it on the scroll 4 steel door g G y g te oe Aa Trey rrrrerTtT TL SEPP ERE EER Rene Wireless Signal Transmitter Scroll Steel Door 8 3 Install the wireless PIR Motion Sensor The PIR sensor will detect a person since human temperature is different to ambient temperature When triggered the PIR will signal the Control Unit Apply the detection area illustration below when installing 77 40 degree Wireless PIR motion sensor 50 degree Surveillance Area 2 1m 5 9m sensor windows infrared infrared 5m 10m 5m 10m Page 23 of 31 Ver 1 2 A Top Safety and Protection Solution In The Worldwide Wireless curt
19. pending on the network condition Size 180mmX125mmX30mm LXWXH Net Weight 0 32Kg 11 Important information 1 Please read the User Manual carefully 2 Do not install the system in close vicinity with objects that generate strong interference such as TV set and computer 3 Install the system in a hidden place 4 Avoid getting water into the Control Unit 5 Have a secure connection to the main power supply 6 This product was designed for the indoor use 7 Opening the control unit cover will avoid the warranty 8 More information will be available of the unit we will not inform you again after we upgraded please check with your dealers 12 Maintenance 1 If the Control Unit works while the remote control and other sensors fail please check and change the battery 2 If the remote control works but the Control Unit fails to send SMS texts switch the power of Control Unit off and switch it on after one minute Test this system after another minute or check the settings are correct and the GSM Signals are strong enough 3 If the Control Unit can run and sensors work but cannot send SMS texts please change SIM Card to check it 4 Ifthe problem cannot be solved please contact the distributor Page 29 of 31 Ver 1 2 A Top Safety and Protection Solution In The Worldwide 13 Warranty 1 This system is warranted to be free of defects in material and workmanship for one year from the date of purchase 2 Th
20. r disarmed mode directly nabled the Watchdog zone In the fixed time range if the sensors in the watchdog zone hasn t been triggered will alarm nabled the system condition report function Will automatically send system condition to the user by SMS otherwise it will not display 6 1 3 Keyboard functions The unit uses the icons to mark the buttons it will be more user friendly to user w Disarm Exit and Backspace button L Arm Stay and Up towards button SOS Down towards button Bala Enter button 3 Turn Left Right button in special menu need it to choose the option 6 2 Main Menu In standby mode press the button you can see the Menu To check the settings and event records of the system To setup the system functions requires password the default password is 1234 Page 11 of 31 Ver 1 2 A Top Safety and Protection Solution In The Worldwide 6 2 1 View To check the alarm records up to 20 event records will be saved To check the Timer you have setup To check the SMS Alert Contents of the Related Zones and its attributes To check the SMS Alert Numbers To check the Auto dial telephone Numbers To check the report time To check the RF sensor wireless code Notice 1 The RF Code Query function is for check the wireless sensor transmission You can enter this submenu then triggered the wireless sensor if in the LCD can display some codes means th
21. sor 4 Also please check the Resistors value is 3 3M Ohm there re 3 Jumpers 1 5M 3 3M and 4 7M if you select incorrect value the wireless distance usually very short or can not learn to the alarm panel a oe y EJ F iie SE E E a de La J 9 2 Enter the RF Sensor Adding Menu See 6 2 2 1 Add Del RF Parts Select the Zone number press Ok finished it then press OK to select the Normal Type Or Stay Type then following the instruction 1 Turn On the Device means trigger the RF sensor the system will show a code then press Enter Key on the Keyboard The system will ask you repeat the operation so please trigger RF sensor again when you see the Code then press the Enter Button on the Keyboard the system will display Saved OK It means the wireless sensor added to the system Repeat this operation to add other wireless sensors Notice a One time can add only 1 wireless sensor b The Name of the RF sensor can be modified by SMS commands Please see chapter 6 3 Page 27 of 31 Ver 1 2 A Top Safety and Protection Solution In The Worldwide 9 4 Add Remote Controls to the Control unit Because of both of the unit and its remote controls are with learning code you can add the remote control to the unit directly following the 6 2 2 1 Add Del RF Parts a Enter the Add Del RF Parts menu b Select 2 Edit Remote Ctrl then press Enter button c then following the instruction 1 Turn On the Device means trigger th
22. tc 4 Physical Layout 4 1 Control Unit physical layout Tips 1 In order to power off the alarm system by intruders we equipped the power switch inside it is nearby the SIMCard socket please pay attention to it and don t tell others of this Turn it towards inside is switch off turn it towards outside is switch on 2 We reserved the plastics of the output relay Because of some of the users needn t this function If you want to use the output relay please remove the plastics carefully Then you can see the output relay connectors inside 3 The left output relay is independent output relay the one nearby the power socket is the alarm link output relay Please pay attention to it Page 5 of 31 Ver 1 2 A Top Safety and Protection Solution In The Worldwide Interface Description Independent Output Relay Can switch on or off by SMS Commands Rated Voltage 3A 250VAC this relay is very useful to switch on light when you can not come back in the evening Then some hours ou can switch off it Link Output Relay when the system alarm will close 4minutes Rated Voltage 3A 250VAC this relay can connect to any other lights or CCTV system as a switch DC Input 9 12V 1000mA Inner is positive electrode outer is negative electrode Siren Socket 12VDC Output Inner is positive electrode outer is negative electrode GSM Antenna Gain 2 0dB Gain 2 5dB for 3m GSM ANT 4 2 Working Principle Drawing
23. te control or press Disarm button on the Keyboard then input the password the Control Unit disarms immediately The fi ICON will be off Under this status any sensor triggered the control unit will not alarm Except the sensor type is the 24 Hour Zones or Watchdog zone or SOS zone Press the button on the remote control or Press the Arm button on the keyboard then select Stay the Control Unit enters Stay Partial Armed status the ICON will be on In this status the sensors had been set as Stay Type triggered will alarm but the sensors had been set as normal Type triggered will not alarm Please see the menu of the Edit RF Zone Press Emergency button SOS on the remote control or the control unit or Press any Emergency button The Control Unit will enter emergency alarm The siren will not sound but will alert the pre set phone number immediately 7 2 SMS Commands for Arm or Disarm or Inquiry system status or switch on off independent output relay The User can Arm Disarm Inquriysystem status Switch on or off the independent output relay by sending SMS to the Control unit The SMS Commands are below Notice The system will carry out the commands immediately with no delay after the Control Unit receive this SMS command 7 2 1 Armed Page 19 of 31 Ver 1 2 A Top Safety and Protection Solution In The Worldwide 000 stands for the password 1 4 digits aio When the Password is 1234 All Armed Mode activated
24. the SMS Alert Content of the Zone Zone or Sensor Name The unit accepts SMS Command to modify the SMS Alert Content of the zone The format is Password M Zone Serial Number New Zone Name the Max Character for the zone name is 32 The Zone Serial Number is 01 16 corresponding to the LCD Menu If setup successful the system will return OK to confirm the operation E g Modify the first wireless zone name as Front Door Opened by Intruder You should edit a SMS Content 1234 M01 Front Door Opened by Intruder the 1234 is the password Then send it to the unit Simcard Number 7 Operating Instructions Tips The user can arm disarm Stay Partial armed by Remote controls Keyboard SMS also the user can cancel the alarm by Remote Controls Keyboard SMS to Disarm it Another the user can switch on or off the independent output relay by SMS Commands 7 1 Arm or Disarm or Stay Partial Arm At House Arm and Emergency Alarm by remote controls ps E a A Press the button fl on the remote control or Press Arm button on the keyboard then select Arm the Control Unit enters arm status delay time Page 18 of31 Ver 1 2 A Top Safety and Protection Solution In The Worldwide according to the setting the fm ICON will be on Under this status any sensor triggered the control unit will alarm if answered the call the siren will stop and can listen in the alarm area by phone Press the button m on the remo
25. wide 5 Equips with 16 Wireless Zones zone attribute Normal At House or Stay mode and Zone Name is editable 6 3X 24 Hour zones for smoke and gas leakage sensor 1XWatchdog zone for monitoring elder or child 1XSOS zone for emergency help 7 Supports 3 SMS Alert Numbers and 5 Calling alert numbers and 20 Alarm Records for owner review 8 Supports Timer for automatically arm or disarm the system 9 Supports armed delay to give enough time to you go out the home the delay time is editable by user 10 N Equips with 1 Alarm Link output relay once the system triggered the output will switch on for 4minutes 11 Equips with 1 independent output relay it can be switch on or off by SMS Commands This is very useful for remote switch on light or off while you re in another city in the night 12 The Keypad can use as a dialer the functions like the Cell phone 13 The external power failure amp recovery alert function is optional 14 Supports wiretap through the internal microphone 15 Supports internal Speaker to special user for two way voice communication 16 Itis Compatible with PT2262 2264 and PT2242 wireless IC 17 Standby internal rechargeable battery which can last 12 hours 18 Based on the GSM communication network and Operation Menu Display technology apply to wide range situations 6 Settings Tips 1 Please insert the SIMCard firstly and install the GSM Antenna then power on it Page 8 of 31

Download Pdf Manuals

image

Related Search

Related Contents

NMR Facility User Manual - Department of Chemistry and  Katrin 953104 paper towel dispencer  aufbauanleitung merlin  User`s Manual - Patient Safety, Inc.  fiche de vente fond plat  Hojas de Tiempo del Servicio Completo  2DNR 3-Axis Gimbal Vari-focal Vandal Resistant Dome Camera    平成 27 年度独立行政法人都市再生機構中部支社 管轄  Avocent DSR2035 Network Card User Manual  