Home
ScopeMeter® 190C/190B Series and
Contents
1. captured 100 screens as a live animation Each screen is labelled with date and timestamp The contents can also be viewed by manually scrolling backwards and forwards screen by screen Replay storage Up to 2 sets of 100 screens each can be saved for later recall and analysis Waveform Compare and Pass Fail Testing Waveform compare Provides storage and display of a reference waveform for visual comparison with newly acquired waveforms Reference is derived from an acquired waveform and can be modified in the ScopeMeter or externally using FlukeView Software Pass Fail Testing 199C 196C In waveform compare mode the Color Scopemeter can be set up to store only matching Pass or only non matching Fail acquired waveforms in the replay memory bank for further analysis Automatic Scope Measurements Vdc Vac rms Vac dc Vpeak max Vpeak min Vpeak to peak Aac Adc Aac dc frequency Hz risetime fall time power factor Watts VA VA reactive phase pulse width pos neg dutycycle pos neg temperature C temperature F dBV dBm into 50 Q and 600 Q Vpwm ac Vpwm ac dc for measurement on pulse width modulated motordrives and frequency inverters Cursor Measurements Source Input A input B or the Mathematical Result trace Dual horizontal lines Voltage at cursor 1 and 2 voltage between cursors Dual vertical lines Time between cursors 1 T between cursors in Hz voltage between markers
2. risetime with markers falltime with markers Single vertical line Min Max and Average voltage at cursor position Zoom Up to 8x horizontal zoom ScopeMeter 190C 190B Series and ScopeMeter 120 Series Meter Mode Via 4 mm banana inputs Fully isolated from scope inputs and scope ground The specified accuracy is valid over the temperature range 18 C to 28 C 65 F to 82 F Add 10 of specified accuracy for each degree C below 18 C or above 28 C Maximum Resolution 5 000 counts Voltmeter Ranges 500 mV 5 V 50 V 500 V 1 000 V Accuracy Vdc 0 5 5 counts Vac true rms 15 Hz 60 Hz 1 10 counts 60 Hz 1 kHz 2 5 15 counts Vac dc true rms dc 60 Hz 1 10 counts 60 Hz 1 kHz 2 5 15 counts Ohms Ranges 500 Q 5 KQ 50 KQ 500 KQ 5 MQ 30 MQ Accuracy 0 6 5 counts Other Meter Functions Continuity Beeper on lt 50 Q 30 Q Diode test Up to 2 8 V Amps Adc Aac Aac dc using an optional current clamp or shunt Scaling factors 0 1 mV A 100 V A Temperature C F With optional accessories Scale factors 1 mV C or 1 mV F Input impedance 1 MQ 1 10 pF 2 pF Advanced meter functions Auto manual ranging relative measurements Zero reference TrendPlot recording FLUKE Recorder Mode ScopeRecord Roll Mode Dual input waveform storage mode Source and display Input A Input B Dual Memory depth 27 500 points per input or more Eac
3. 0 Series is the rugged solution for industrial troubleshooting and installation applications It s a truly integrated test tool with oscilloscope multi meter and paperless recorder in one affordable easy to use instru ment Find fast answers to problems in machinery instrumentation control and power systems e A dual input 40 MHz or 20 MHz digital oscilloscope e Two 5 000 counts true rms digital multimeters e Cursor measurements Fluke 124 e A dual input TrendPlot recorder e Connect and View trigger simplicity for hands off operation e Shielded test leads for oscillo scope resistance continuity and capacitance measurements e Full bandwidth VPS40 10 1 40 MHz probe included standard with Fluke 124 e Up to seven hours battery operation 600 V CAT III safety certified Optically isolated RS 232 interface e Rugged compact case Technical Specifications 190C and 190B Series Oscilloscope Mode Vertical Deflection Bandwidth 200 MHz 100 MHz 60 MHz Rise time 1 7 ns 3 5 ns 5 8 ns Bandwidth limiter User selectable 10 kHz 20 MHz or off Number of inputs 2 plus external trigger All inputs isolated from each other and ground Input coupling AC or DC with ground level indicator Input sensitivity 2 mV div to 100 V div Fluke 190C Series 5 mV div to 100 V div Fluke 190B Series Variable attenuator Variable gain on input channel A Input voltage 1000 V CAT II 600 V CAT I
4. I instrument and included accessories 7 hr NiMH 5 hr NiCd Battery installed 4 hr Ni MH BP190 Line Power Adapter battery charger included Size 25 x 16 9 x 6 4 cm 10 1 x 6 7 x 2 5 in 232 x 115 x 50 mm 9 2 x 4 5 x 2 in Weight 2 kg 4 4 1b 1 2 kg 2 64 lbs PC and Printer Interface Using optional optically isolated RS 232 adapter cable Warranty 3 years on main instrument 1 year on the standard accessories Detailed technical specifications and optional accessories can be found on the Fluke web site There you can also download a fully functional instrument which is based on the real instrument firmware Check it out at www fluke com scopemeter OTxe Valalomiaicclsaat iiiela Fluke 199C S Color ScopeMeter 200 MHz 2 5 GS s BP130 Rechargeable NiMH Battery for use with with SCC190 kit Fluke 120 Series Fluke 199C Color ScopeMeter 200 MHz 2 5 GS s BP190 Rechargeable NiMH Battery for use with Fluke Keeping your world Fluke 196C S Color ScopeMeter 100 MHz 1 GS s Fluke 190 Series ScopeMeters up and running with SCC190 kit SW90W FlukeView ScopeMeter Software for Fluke 196C Color ScopeMeter 100 MHz 1 GS s Windows Fluke 199B S ScopeMeter 200 MHz 2 5 GS s with PM9080 Optically isolated RS232 adapter cable Fluke Corporation SCC190 kit SCC190 Software Cable Case kit for Fluke PO Box 9090 Everett WA USA 98206 Fluke 199B ScopeMeter 200 MHz 2 5 GS s 190 Series Fluk
5. II rated See general specifications for further details Vertical resolution 8 bit Accuracy 1 5 of reading 0 04 x range div Input impedance 1 MQ 1 15 pF 2 pF Fluke 192B Horizontal Fluke 199C Fluke 199B Fluke 196C Fluke 196B Maximum 1 GS s 500 MS s real time sample rate Number of 2 2 2 digitizers Time base 5 ns div 10 ns div range to 5 s div to 5 s div Maximum record length 1 200 points per input in Scope mode 27 500 points per input in ScopeRecord roll mode 5 ms div to 2 min div Accuracy 0 01 of reading 1 pixel Glitch capture 50 nsec at 5 psec div to 1 min div 250 nsec at 2 min div Display and Acquisition 144 mm 5 67 monochrome LCD Input A input B dual average invert replay persistence on off 144 mm 5 67 full color LCD Input A input B dual average invert replay Digital Persistence mode short medium long infinite Display Display modes Visible screen width 12 divisions in scope mode Waveform mathematics A B A B A B all with user selectable scaling of resultant A versus B X Y mode Acquisition modes Normal auto single shot ScopeRecord roll glitch capture waveform compare waveform compare with automatic Pass Fail testing in 199C and 196C only Trigger and Delay Source Input A input B external trigger input All input references isol
6. ScopeMeter 190C 190B Series ScopeMeter 190C and 190B Series Speed performance and analysis power e For demanding applications the ScopeMeter 190C and 190B Series e high performance oscilloscopes offer specifications usually found on top end bench instruments With up to 200 MHz bandwidth 2 5 GS s real time sampling and a deep memory of 27 500 points per input they re ideal for engineers who need the full capabilities of a high performance scope in a hand Connect _held battery powered instrument 4 and IEW Dual input 200 100 or 60 MHz bandwidth Up to 2 5 GS s real time sampling per input Connect and View automatic triggering a full range of man ual trigger modes plus external triggering Digital Persistence for analyzing complex dynamic signals like on an analog oscilloscope 190C Fast display update rate for seeing dynamic behavior instantaneously Automatic capture and replay of 100 screens FLUKE Technical Data e 27 500 points and more per input record length using ScopeRecord mode e TrendPlot paperless recorder for trend analysis up to 22 days e 1 000 V CAT II and 600 V CAT III safety certified e Waveform reference for visual comparison and automatic pass fail testing 190C of waveforms e Up to 1 000 V independently floating isolated inputs e Four hours rechargeable NiMH battery pack ScopeMeter 120 Series Three in one simplicity The compact ScopeMeter 12
7. ated from each other and from ground Modes Automatic Connect and View free run single shot edge delay video video line selectable pulsewidth 2 Fluke Corporation Connect and View Advanced automatic triggering that recognizes signal patterns automatically sets up and continuously adjusts triggering time base and amplitude Automatically displays stable waveforms of complex and dynamic signals like motor drive and control signals Video triggering NTSC PAL PAL SECAM Includes field 1 field 2 and line select Pulse width triggering Pulse width qualified by time Allows for triggering lt t gt t t t where t is selec table in minimal steps of 0 01 div or 50 nsec Time delay One full screen of pre trigger view or up to 100 screens 1200 divisions of post trigger delay Automatic Capture of 100 Screens The instrument ALWAYS memorizes last 100 screens no user interaction or setup required When an anomaly occurs on screen the HOLD button can be pressed to review the full screen sequence over and over Instrument can be set up for triggering on glitches or intermittent anomalies and will operate in paby sit mode and will capture 100 events Alternatively the 199C and 196C can be set up in waveform compare mode to store only matching Pass or only non matching Fail acquired wave forms in the replay memory bank for further analysis Replay Manual or continuous replay Displays the
8. e 196B S ScopeMeter 100 MHz 1 GS s with SCC120 Software Cable Case kit for Fluke Fluke Europe B V SCC190 kit 120 Series PO Box 1166 5602 PD Fluke 196B ScopeMeter 100 MHz 1 GS s C195 Durable universal soft carrying case for Eindhoven The Netherlands Fluke 192B S ScopeMeter 60 MHz 500 MS s with ScopeMeters and accessories For more information call SCC190 kit C190 Hard shell protective carrying case for In the U S A 800 443 5853 or Fluke 192B ScopeMeter 60 MHz 500 MS s Fluke 190 Series ScopeMeters Fax 425 446 5116 Fluke 124 S Industrial ScopeMeter 40 MHz with C125 Durable protective soft carrying case for In Europe M East Africa 31 0 40 2675 200 or SCC120 kit Fluke 120 Series ScopeMeters Fax 31 0 40 2675 222 Fluke 124 Industrial ScopeMeter 40 MHz C120 Hard shell protective carrying case for In Canada 800 36 FLUKE or Fluke 123 S Industrial ScopeMeter 20 MHz with Fluke 120 Series ScopeMeters Fax 905 890 6866 SCC120 kit DP120 Differential Voltage Probe for use with From other countries 425 446 5500 or Fluke 123 Industrial ScopeMeter 20 MHz Fluke 120 Series Fax 425 446 5116 BP120 Rechargeable NiCd Battery for use with VPS40 40 MHz 10 1 Voltage probe set for use Web access http www fluke com Fluke 120 Series with Fluke 120 Series 2002 Fluke Corporation All rights reserved Trademarks are the property of their respective owners Printed in U S A 11 2002 1629083 D ENG N Rev C
9. ensing Maximum operating altitude 3 000 m 10 000 feet Maximum storage altitude 12 km 40 000 feet Electro Magnetic Compatibility EMC EN 61326 1 for emission and immunity Optically Isolated PC Printer Interface PC communication Transfer instrument settings screen images waveform data and waveform references compatible with FlukeView software for Windows via optional PM9080 To printer Supports HP Laserjet DeskJet Epson FXO and Postscript printers via optional PAC 91 Warranty 3 years parts and labor on mainframe instrument 1 year on accessories BP190 Line voltage adapter Battery charger BC190 Voltage probes and accessories 10 1 voltage probe VPS200 1 red 1 grey including hook clip ground lead with mini alligator clip ground lead with hook clip 4 mm add on probe tip ground lead to 4 mm banana plug Multimeter test leads TL75 Hard Point test lead set lred 1 black User manual 9 language versions on CD ROM Getting Started booklet included with instrument 4 Fluke Corporation ScopeMeter 190C 190B Series and ScopeMeter 120 Series FLUKE International Safety Standards Overvoltage Category Summary description CAT IV Three phase at utility connection any outdoors conductors under 1 000 V Outside and service entrance Service drop from pole to building Run between meter and panel Overhead line to detached building Underground li
10. h point consists of Min Max pair Min Max values Min Max values are measured at high sample rates ensuring capture and display of glitches 5 ms div to 1 min div Recorded timespan 6 sec to 24 hr 48 hr Glitch capture 50 ns 250 ns Sample rate 20 MS s 4 MS s Resolution 200 jisec to 2 sec 4 8 sec Recording modes Single sweep continuous roll Start on Trigger Stop on Trigger Stop on Trigger through external ScopeRecord mode can be stopped by an individual trigger event or by an interruption of a repetitive trigger signal Horizontal scale Time from start time of day Zoom Up to 100x Memory Up to 2 dual input ScopeRecord waveforms can be saved for later recall and analysis TrendPlot recording Single or dual input electronic paperless chart recorder Plots displays and stores meter and scope measurements Source and display Input A Input B or DMM input Memory depth 18 000 points recording Per record point a minimum a maximum and an average value plus a date and timestamp are recorded Ranges 5 s div to 30 min div in normal view mode 5 min div to 48 hr div in view all mode giving overview of total record Recorded timespan Up to 22 days with a resolution of 1 minute Recording mode Continuous roll for the duration of the full recordable timespan Measurement speed 5 measurements per second Horizontal scale Time from start time of day Zoom Up to 64x zoom Memory Up to 2 TrendPlot rec
11. ndependently floating Up to 1000 V between inputs references and ground isolated inputs Input sensitivity Glitch capture Timebase range in Scope mode 2 mV div to 100 V div 5 mV div to 100 V div Up to 3 ns using pulse width triggering 50 ns peak detect at 5 ms div to 1 min div 5 ns div to 2 min div 10 ns div to 2 min div Connect and View Free Run Single Shot Edge Delay Video Frame Video Line Selectable Pulse Width and External 7 cursor measurements 30 automatic measurements 5 mV div to 500 V div 40 ns 10 ns div to 20 ns div to 1 min div 1 min div Connect and View Free Run Single Shot Edge Video cursors 26 26 automatic Trigger types Scope measurements automatic measurements measurements Waveform mathematics A B A B A x B A versus B X Y mode giving Lissajous diagrams ScopeRecord trigger modes Start on trigger stop on trigger Capture last 100 screens Automatic with replay capability Dual input TrendPlot Yes with cursors and zoom Yes Memory for screens and 10 screens with set up set ups 5 more memories are made available upon registration of the ScopeMeter 20 10 Memory for recordings True rms multimeter Safety certified EN61010 1 Two each can store 100 scope screens a ScopeRecord or a TrendPlot 5000 counts Volts Amps Ohms Continuity Diode Temp 1000 V CAT II 600 V CAT III instrument and included accessories 600 V CAT II
12. ne to well pump Three phase distribution under 1 000 V including single phase commercial lighting and distribution panels Feeders and short branch circuits e Distribution panel devices Heavy appliance outlets with short connections to service entrance Single phase receptable connected loads Outlets and long branch circuits e All outlets at more than 10 m 30 ft from Category III source All outlets at more than 20 m 60 ft from Category IV source Electronic Electronic equipment Low energy equipment with transient limiting protection CAT III CAT II CAT I To protect your instrument and more importantly yourself choose a test tool that can withstand the electrical hazards present in the environment in which you plan to use it EN61010 establishes international safety require ments for electrical measurement equipment It separates the various electrical environments into installation categories based on the danger from high elie wo om q Bi SS 7 o T car m p D SKS oo S o o voltage energy transients To choose the right tool the voltage rating alone does not determine the safety It is the combination of voltage rating and installation category that determines maximum tran sient withstand capability of the tool CAT III rated in
13. oltage adapter battery charger included Battery power Rechargeable NiMH installed Battery operating time 4 hours Battery charging time 4 hours Battery power saving functions Auto power down with adjustable power down time On screen battery power indicator Mechanical Data Size 256 x 169 x 64 mm 10 1 x 6 6 x 2 5 in Weight 2 kg 4 4 lbs Accessories Standard Accessories Fluke 199C Fluke 196C Fluke 199B Fluke 196B Fluke 192B Rechargeable battery pack installed Safety Compliance EN61010 1 1993 Pollution degree 2 UL 3111 1 1994 CAN CSA C22 2 No 1010 1 1992 ANSI ISA 82 01 1994 Input Voltage Ratings Maximum probe voltage 1 000 V CAT II 600 V CAT III Maximum voltage between 10 1 probe tip VPS200 and reference lead Floating voltage 1 000 V CAT II 600 V CAT III Maximum voltage between earth ground and any terminal signal input or shielding Independently isolated inputs 1 000 V CAT II 600 V CAT III Maximum voltage between any terminal of one input or probe VPS200 and any other terminal of another input or probe VPS200 Maximum voltage on BNC input directly input A or B 300 V CAT III Maximum voltage on meter input 1 000 V CAT II 600 V CAT III Environmental Operating temperature O C to 50 C Storage temperature 20 C to 60 C Humidity 10 C to 30 C 95 RH non condensing 30 C to 40 C 75 RH non condensing 40 C to 50 C 45 RH non cond
14. ordings can be saved for later recall and analysis Cursor measurements all recorder modes Source Input A B or DMM input Dual vertical lines Min Max or Average voltage Time between cursors Single vertical line Min Max or Average voltage Absolute date and time or time from start ScopeMeter 190C 190B Series and ScopeMeter 120 Series Fluke Corporation 3 General Specifications Case Design Rugged shock proof with integrated protective holster Drip and dust proof IP51 according to IEC529 Shock and Vibration Shock 30 g Vibration sinusoidal and random 3 g according to MIL PRF 28800F Class 2 Bright full color LCD Bright monochrome LCD Display with CCFL backlight with CCFL backlight 80 30 Cd m 125 75 Cd m with with without power adapter without power adapter Display size 115 2 x 86 4 mm 4 54 x 3 4 in Resolution 320 x 240 pixels Contrast and brightness User adjustable temperature compensated Memory Save and Recall Scope memories 10 memory locations that each can contain two waveforms plus corresponding setup Recorder memories 2 memory locations that each can contain 100 captured dual input scope screens or a dual input ScopeRecord 27 500 Min Max pairs per input or a dual input Trendplot 18 000 min max pairs average values Real Time Clock Time and date stamp for ScopeRecord 100 captured screens and TrendPlots Power Line power Country specific line v
15. struments are recommended for measurement on industrial power distribution systems FlukeView ScopeMeter Software for Windows FlukeView software adds PC power to your Fluke ScopeMeter Test Tools FlukeView ScopeMeter software helps you get more out of your ScopeMeter e Store instrument s screen copies on the PC in color with Fluke 190C Series or in black and white Fluke 190B and 120 Series e Copy color screen images into your reports and documentation color screen images with Fluke 190C Series only e Capture and store waveform data from your ScopeMeter on your PC e Create and archive waveform references for auto matic Fluke 190C Series or visual Fluke 190B and 190C Series comparison e Use cursors for parameter measurement e Includes waveform analysis e g FFT spectrum analysis e Copy waveform data into your spreadsheet for detailed analysis e Extended recording of up to four user selected measurements help you monitor and analyze slow moving signals and related events e Logging of other readings directly into other appli cation programs eg spreadsheet e Add user text to instrument setups and send these to the instrument for operator reference and instructions e Capture complete Replay sequence into the PC for further analysis and documentation e English French and German versions included on a single CD ROM Note Some functionality may be available with specific ScopeMeter models only s
16. ystem requirements e Pentium 90 or better e CD ROM drive e Windows 95 98 Me NT 4 0 2000 XP e One free RS 232 port e PM9080 Optically isolated RS 232 adapter cable available separately or included in SCC190 SCC120 kit and in ScopeMeter S versions Supported Instruments Full support for Fluke 199C 199B 199 196C 196B 196 192B 192 124 123 ScopeMeter 190C 190B Series and ScopeMeter 120 Series Fluke Corporation 7 FLUKE Selection Guide 190C Color ScopeMeter Series 190B ScopeMeter Series Fluke 120 Series Fluke 199C Fluke 196C Fluke 199B Fluke 196B Fluke 192B Fluke 124 Fluke 123 Bandwidth 200 MHz 100 MHz 200 MHz 100 MHz 60 MHz 40 MHz 20 MHz Max real time sample rate 2 5 GS s 1 GS s 2 5 GS s 1 GS s 500 MS s 25 MS s Max equivalent time sample rate 2 5 GS s 1 25 GS s 144 mm full color LCD Yes gives analog oscilloscope like waveform decay user selectable Yes Visual reference and automatic Pass Fail testing Display 144 mm monochrome LCD 102 mm monochrome LCD Digital persistence Yes Yes Visual reference Envelope mode Waveform compare Max record length in Scope Mode 1200 points per input channel 512 min max points per input in ScopeRecord mode 27 500 points per input or more 5 ms div to 2 min div Number of inputs 2 plus external DMM input all isolated from each other and from ground 2 Number of digitizers 2 2 I
Download Pdf Manuals
Related Search
Related Contents
Jabra LP 850 User's Manual contrat de vente de la licence d`utilisation du Genie Z-80, Z-60 Personal Lift User Manual ブレーキ開放ワイヤー 設置要領書(300J-MRL) JVC SR-VD400E User's Manual Hayter Mowers Powertrim 407F User's Manual Tripp Lite Alternative Power Sources User's Manual XTD-7000DT_manuale Copyright © All rights reserved.