1. 2 6 Delete Low Temperature Alarm Set 2 7 Temperature t alibfa tion 2 8 Temperature Alarm Delay 2 9 Each Group temperature Alarm ON OFF 240 Alarm Text For High Temperature 2 11 Reset To Default Message For Temperature 2 12 Input Message for the Recovery Temperature to ssssseennazennenzzznntannzantenzastenzazontnnaa 2 13 Input Message for the Low Temperature 3 System Alarm Alert Programming 3 1 Cal Alert For a e dal A B 10 10 10 10 10 11 11 12 12 12 12 13 2 Page GSM 0308T User Manual Applications This product is suitable for farms refrigerator laboratorv humiditv box green house for vegetables amp fruits aquarium etc Can use SMS to remotely Enquiry for Temperature Value Setting for High Low Temperature Alarm Set Point Temperature Calibration Text Content for Alarm Alert Call Alarm Alert 2 Channels Temperature Alarm Alert can split to 1 Channel use for Temperature Control 1 Channel use for Temperature Alarm Alert Refrigerated Warehouse Chicken Farm Aquarium HEE 4 MU Humiditv Box Gree
2. User Manual GSM TEMPERATURE CONTROLLER AND MONITORING SVSTEM Model GSM 0308T GSM 0308T User Manual Table of Contents Application EAE EEEE AE META Instructions EE ANA tt Installation iii ie en bed s 4 Device Design PA EN 5 Technical INStrUCHON eae eco 1 Administrator 1 1 Tempora Administrator Att 1 2 Cnan ine a wa da 1 3 an Administrator NUMDE i a 1 4 Enquiry to Administrator Numbers in the 115 1 5 Delete Administrator Number in the list 0 ann nnnnanznnnanznntaa 1 6 Sie al SUL M OUR i EE aes 1 7 Time Schedule to send SMS Reminder to the Administrator ss ssseeesennnanzznnnnzzennanznnnnzznznnzana 2 Temperature Alert Programming 2 1 Enquiry For Current Temperature 2 2 High Temperature Alarm oet POLAT see iii a 2 3 Low Temperature Alarm Set a 2 4 Enquiry For Temperature Alarm Set 2 5 Delete High Temperature Alarm Set
3. BBB 6 Character New Password At the same time it will get the Administrator Privilege Example Send 100 123456 0bs123 the system will change the admin to obs123 100 123456 obs123 New password obs123 Add an Administrator Number 101 A BBBBBB Add administrators to the Administrator List A Administrator no 1 5 BBBBBBBB Tel no of new administrator You can add a Minimum of 3 digits and a maximum of 20 digits Example Send 101 5 13812512456 System will set 13812512456 as Admin 5 Send 101 3 123456 System will set 123456 as Admin 3 101 5 13812512456 Administrators 1 17817777070 2 d 4 5 13812512456 101 3 123456 Administrators 1 17817777070 2 3 123456 4 5 13812512456 7 Page GSM 0308T User Manual 1 4 1 5 1 6 Enquirv to the Administrator Numbers in the list 102 Check administrator list It will reply with a full list of all administrators on the list 102 Administrators 1 17817777070 2 3 123456 4 5 13812512456 Delete Administrator Number in the list 103 A Deleting administrator tel no on the list administrator 1 5 Example Send 103 5 the system will delete the Admin 5 103 5 Administrators 1 17817777070 Enquiry Signal Strength 104 Check signal strength on the GSM connection Enquiry for Signal Strength CSQ 0 10 Weak Signal CSQ 11 20 Average Signal CSQ 21 30 Goo
4. Device Design 5 Page GSM 0308T User Manual Technical Parameter Power Supply Single Phase 220V 240V 50 60Hz GSM Frequency GSM900 1800Mhz Optional GSM850 900 1800 1900Mhz Device Power lt 2W Backup Battery 7 4V 600mAH Lithium Polymer Battery Maximum Load For Control 10A 277VAC 12 125VAC Remote Monitoring Distance GSM network coverage area Physical Casing Dimension 180mm x 140mm x 60mm Enclosure IP Rating IP65 Temperature Monitoring Area 49 C to 129 C Temperature Error 1 C Temperature Channel 2 Channels Temperature Sensor Type S 58LM20A Setup via SMS Command 1 1 1 Administrator Temporary Administrator Privilege 100 AAAAAA Setting up a Temporary Administrator Privilege for Programming Mode AAAAAA 6 Digits Password Default Password 123456 By using this commando you will obtain administrator privilege for 10 Minutes That means you can do all programming within those 10 Minutes If you add your tel no in the administrator list you do not need this function anymore If another uses same commando within the 10 Minutes then you will lose your Administrator privilege All tel no on the Administrator list have full control over the unit at all time 100 123456 You get administrator privileges 6 GSM 0308T User Manual 1 2 1 3 Changing a Password 100 AAAAAA BBBBBB Change the password AAAAAA 6 Character Old Password BBB
5. d Signal CSQ Above 30 Excellent Signal 104 CSQ 20 8 Page GSM 0308T User Manual 1 7 2 2 Time Schedule to send SMS Reminder to the Administrator 109 XXX SMS check message to say the unit is still up and running XXX Days Value 000 255 must be in 3 digits every week 007 Default as 000 Not Sending SMS reminder Default Text reads as Hi I m Can edit the text using 111 Command Example send 109 002 the system will start to calculate from the moment it receives the SMS After 2 days it will send out a SMS reminder Note If the system had been restarted it will clear the time to ZERO and recalculate again for 2 days from the moment the system restarted then send out the SMS reminder after 2 days 109 002 Send message frequency 2 days Temperature Alert Programming Enquiry for Current Temperature Value 600 This will check the current temperature for the sensor High Temperature Alarm Set Point 601 No of channel for Temperature Sensor BBB Temperature set point from 49 to 129 C Temperature set point when negative must be in front always 3 digits so 5 degree 005 etc Example Send 601 1 19 which means channel 1 Temperature Probe detects the temperature If it s more than 19 C it will now Alarm Alert Note when setting high temperature The temperature must be higher than the low temperature value 9 Page GSM 0308T U
6. ecovery Temperature to Normal 610 A BBBBBBBBB A No of channel for Temperature Sensor BBBBBBBBB text for alarm text when temperature is recovered Input Message for the Low Temperature Alert 611 of channel for Temperature Sensor BBBBBBBBB Alarm text for low temperature alarm 12 Page GSM 0308T User Manual 3 System Alarm Alert Programming 3 1 Call Alert for Trigger Tvpe Alarm 302 B 0 or 1 0 OFF 1 default as when alarm will not message before phone call alert A Trigger Types as per below 1 System Restart 2 Power Outage 3 Power Recover 4 High Temperature 5 Temperature Recover 6 Low Temperature 7 Line Cut 8 Line Cut Recover Example Send 302 4 1 when the temperature is over the high level set point the system will make a phone call to Administrator 1 and send a corresponding SMS to all Administrators If the call is not answered the system will continue to call the 5 Administrator Number simultaneously Example Send 302 6 0 he temperature is over the low level set point the system will not call you The system only send an alert message Note you can choose as many of them you want which means you can simple choose to on off the call function of the 8 Types of Alarm Alert For more additional command please refer to Additional Command List For GSM 0308 Series 13 Page
7. n House For Vegetables amp Fruits 3 Page GSM 0308T User Manual Instructions After connect to the unit put the temperature probe at the object vou need to monitor Once the temperature is abnormal the device will SMS phone call to inform vou Maximum 5 group administrator can be set up to receive alarm alerts 6 simple steps to use the device Insert the SIM card Connect the Temperature probe Plug in the power cable into the power supply socket Switch on the On Off switch After the device starts make a call to the device call the SIM card phone number Use SMS to set the High Low Temperature Value Note When hear a di sound you can determine the equipment has been start successfully When it reply as follows it is ready to use Insert SIM Card MIT V 5088 TEA Administrators w 1 17817777070 Q 2 3 4 5 Setting Channel 1 High Temperature Value 36 C 601 1 036 Setting Channel 1 Low Temperature Value 0 602 1 000 Setting Channel 2 High Temperature 10 601 2 10 Setting Channel 2 Low Temperature Value 30 602 2 0 123 123 Temperature Temperature Channel 2 Channel 1 4 Page GSM 0308T User Manual Installation Diagram Battery Fully Charged LED Indicator Factory Reset Button System Operating Alarm On Off On Off Power Power COM Relay LED LED Indicator LED indicator Switch Neutral Life Indicator
8. ow be adjusted 10 Page GSM 0308T User Manual 2 8 2 9 Temperature Alarm Delav Time 607 A BBBB A No of channel for Temperature Sensor BBBB delay time in seconds from 0001 to Max 6553 seconds Max 109 minutes Delay is always 4 figures 1 second 0001 Default 0001 Example Send 607 1 00254 when Channel 1 Temperature detected abnormal temperature if this happens for more than 25 seconds it will send an alarm But if the temperature is recovered it will not send the alarm Each Group Temperature Alarm ON OFF 608 XX XX First X as Channel 1 Second X as Channel 2 Sensor OFF 0 ON 1 Default ON Example Send 608 01 this means that sensor 1 is OFF and Sensor 2 is ON This is an Easy way to temporary switch off the temperature alarms Example If you want to set 2 Channels Temperature Alarm Alert can split to 1 Channel use for Temperature Control 1 Channel use for Temperature Alarm Alert Please set as below Channel 1 Channel 2 using the same temperature probe Use wire to connect together the temperature probe with same marking of 2 Note The marking of 1 as temperature power marking of 2 as signal marking of 3 as temperature power Channel 1 setting as OFF alarm alert activate the linkage Send 205 11 to activate Linkage Send 304 0 1 1 the main relay will linkage with Temperature channel 1 Relay out connect with one cooling Fan and setting the temperature as High Tempera
9. ser Manual 2 3 2 4 2 5 2 6 2 7 Low Temperature Alarm Set Point 602 No of channel for Temperature Sensor BBB Temperature set point from 49 to 129 degrees Temperature set point when negative must be in front alwavs 3 digits so 5 degree 005 etc Example Send 602 1 43 which means channel 1 Temperature Probe has detected the temperature less than 43 C it will now Alarm Alert Note Setting low temperature The temperature must be lower than the high temperature value Enquiry For Temperature Alarm Set Points 603 Enquire temperature alarm set points Check what set points have been programmed in the unit already Delete High Temperature Alarm Set Points 604 X X No of channel for Temperature Sensor Deleting the alarm set point for high temperature Example Send 604 2 will delete the alarm set point for sensor 2 of the HIGH TEMPERATURE alarm Delete Low Temperature Alarm Set Points 605 No of channel for Temperature Sensor Deleting the alarm set point for low temperature Example Send 605714 will delete the alarm set point for sensor 1 of the LOW TEMPERATURE alarm Temperature Calibration 606 No of channel for Temperature Sensor 5 to 5 calibrate temperature up and down max 5 degrees Example When channel 2 temperature is more than the actual temperature by 3 C then send 606 2 3 the temperature will n
10. ture Set Point as 110 Low Temperature Set Point as 105 Channel 2 setting as ON alarm alert setting the temperature as High Temperature Set Point as 125 The process as below When the temperature slowly increase and over 110 C the temperature at channel 1 will activate relay The relay will activate the cooling fan If the temperature slowly decrease not over 125 C and continue till lower than 105 C the temperature at channel 1 will OFF the cooling fan If the temperature did not decrease cooling fan facing error and over 125 C channel 2 temperature alarm will send out a SMS to alarm alert 11 Page GSM 0308T User Manual 2 10 2 11 2 12 2 13 Alarm Text for High Temperature Alarm 609 A BBBBBBBBB A No of channel for Temperature Sensor BBBBBBBBB Alarm text for high temperature alarms Max 100 Characters Example Send 609 4 High temperature alarm when channel 4 sends out an alarm you will get the report message High temperature alarm NOTE When changing text string for this it will not send the Temperature Set point as it does when set to default alarm text Default alarm text is High temperature 1 alarm xx degree Celsius temperature during the alarm alert Reset To Default Message For Temperature Alert 609 No of channel for Temperature Sensor Example Send 609 4 channel 4 will reset the alert text back to factory default Input Message for the R

Download Pdf Manuals

image

Related Search

Related Contents

REVISION HISTORY AG3E  Emerson Process Management Series 100 Gas Analyzers HYDROS 100 User's Manual    Baumatic BRB2713 fridge-freezer  LIEBERMAN PROCESS TROUBLESHOOTING  Manual248 KB - FSH Locking  Manuel d`utilisation (Version 0.5.X) : WinPost - 5axes  User manual - Zerosum Security  LIVELLO取扱説明書 Click  Samsung SGH-D900 Наръчник за потребителя  