1. 120 mins Diagram 3 MOUNTING AND INSTALLATION CONTINUED Step 5 To adjust lux level i e the ambient light level at which you would like your lights to be activated via the PIR sensor please refer to the lux level rotary adjuster diagram Rotate the lux level adjustment clockwise to decrease the level of light required to turn the lights on and anticlockwise to increase the level of light required to turn the lights on See diagram 1 for position of lux level adjustment Replace fascia ring by turning clockwise one quarter turn INSTALLATION NOTES N B After installation the PIR will require approximately 5 minutes to initialise OPERATION 1 In standard operation the PIR will now sense body heat when passing through the detection zone Each time the PIR is triggered it will reset the timer back to the start of the timing period The unit will then wait 20 seconds approximately before allowing the PIR unit to sense and re trigger the timing period again 2 If no one is present in the room or the detection zone is not passed through during its set time period the timer will time out turning off the lights or appliance 3 The PIR unit will only trigger the lights or appliance if the ambient light level is below that set on the lux level adjustment IMPORTANT NOTICE All wiring should be carried out by a competent person or a qualified Electrician in accordance with the current IEE Wiring Regulations If unit is faulty return to place of pu
2. cent to the load Do not site the X 5 unit on a vibrating surface or near a forced air heating or pee 5 ventilation see diagram 2 7 metres approx z Diagram 2 MOUNTING AND INSTALLATION Important Please note that it is essential that the Live In wire and switch Live Out is identified prior to commencing installation Turn off mains supply for installation Step 1 Cut a hole measuring 64mm in diameter in the chosen area for the sensor Please see positioning Step 2 Place the Live In wire into the left hand position of the connector the switched Live Out wire into the second from left position of the connector and neutral into right hand position of connector see diagram 1 Step 3 Fold the two arms up into the vertical position and insert unit into hole Release unit ensuring arms are securely in place Step 4 To set time as per timing table remove fascia ring by turning anti clockwise one quarter turn to access switches one through four Depending on required time available from 2 minutes to 2 hours E g 10 minutes switch one off switch two on switch three off switch four off see diagram 3 K Elkay Electrical Coleshill Birmingham England q g Tel 44 0 1675 468222 www elkay co uk Patent Pending Inst Ref No PIRC301 Rev No 04 07 90 mins 100 mins TIO mins
3. energysense energystyle pirsensor energyoutdoor ceiling mount pirsensor fitting amp operating instructions RATING AT 240V AC Product 374A 1 374A 2 Three wire Incandescent 16A Fluorescent 16A Compact 16A Fluorescent Resistive 16A USAGE Time Delay 2mins 2hours The ceiling mount pirsensor is part of the Elkay family of switches timers and detectors which save energy and increase convenience in and around your home garden or premises i The PIR sensor has been designed to replace a single OIO ZOOO gang light switch to control lighting heating and ventilation The unit is pE O E Ra switched on by the ETS Fa PETA a A detection of moving body WA i 4 i i Nie Bias heat within a specified it i T r E range When body heat is a gin i S A Ppa no longer detected the AW OO RA unva i unit will switch off after N mi E ee w the adjustable time period has elapsed If moving body Diagram 1 heat is detected again during the timing period the timing sequence will restart The unit has a lux level adjustment which measures the ambient light levels and prevents lighting being switched on when there is sufficient light in the room POSITIONING Use the detection range to determine a suitable location EEG for the sensor When locating the position of the unit 9 S avoid subjecting the sensor to direct sunlight Ensure that 3 the sensor is not adja
4. rchase TECHNICAL HELPLINE For further help or information on this and the other products in the Elkay range visit www elkay co uk or call 01675 468222 K Elkay Electrical Coleshill Birmingham England q yg Tel 44 0 1675 468222 www elkay co uk Patent Pending Inst Ref No PIRC301 Rev No 04 07

Download Pdf Manuals

image

Related Search

Related Contents

Manual de Usuario Tienda Virtual Access7x24  fichier pdf, 6.0 Mo    solucion 64 14.120 ve sp_064_07  Progress Lighting P5511-31 Instructions / Assembly  PDF 表示  Detector - Technical measures for information security protection  口雄品は住宅用です。 業務用途では使用できません。 口  

Copyright © All rights reserved.
Failed to retrieve file